18
ARCHITECTURAL DRAWINGS

ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

ARCHITECTURAL DRAWINGS

Page 2: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

A

A

11

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

K

K

L

L

90 m²

Multi-purpose Hallfloor tiles

13 m²

Consulting Officefloor tiles

22

44

55

66

77

88

99

1010

1111

12 m²

Consulting Officefloor tiles

10 m²

Sick Bayfloor tiles

33

10 m²

In-takefloor tiles

10 m²

Screeningfloor tiles

10 m²

Cleaner Storefloor tiles

30 m²

Boardroomfloor carpet

29 m²

Staff/Kitchenfloor tiles

12 m²

Consulting Officefloor tiles

12 m²

Consulting Officefloor tiles

15 m²

Community Dev.Supr.floor tiles

38 m²

Com. Dev.Pract.floor tiles

51 m²

Circulation Areafloor tiles

12 m²

Quiet/Obser.floor tiles

15 m²

Group/Interviewfloor tiles

15 m²

Suprv.Social Workerfloor tiles

12 m²

Femalefloor tiles

9 m²

Malefloor tiles

10 m²

Malefloor tiles

13 m²

Femalefloor tiles

4 m²

Paraplegicfloor tiles

10 m²

Store Roomfloor tiles

10 m²

IT/Serverfloor tiles

10 m²

Print Roomfloor tiles

20 m²

Registryfloor tiles

10 m²

Archivefloor tiles

15 m²

Play Roomfloor tiles

10 m²

Store Roomfloor tiles

12 m²

Securityfloor tiles

12 m²

Consulting Officefloor tiles

12 m²

Consulting Officefloor tiles

12 m²

Consulting Officefloor tiles

12 m²

Consulting Officefloor tiles

25 m²

Admin Supp.floor tiles

19 m²

Head Of Facilitiesfloor tiles

25 m²

Meeting Areafloor tiles

15 m²

Meeting Areafloor tiles

6 m

²

Ba

tte

ry B

an

k R

Mfloor

tile

s

11 m²

Stationaryfloor tiles

1212

1313

1414

10 m²

Waiting Areafloor tiles

57 m²

Office Open planfloor tiles

71 m²

Circulation Areafloor tiles

52 m²

Office Open planfloor tiles

49 m²

Waiting Areafloor tiles

20 m²

Receptionfloor tiles

15 m²

Library/Computer Labfloor tiles

PLA

NT

ER

3105

4635

2115

3880

5550

3850

2030

4500

1730

4270

3160

3700

1655

44180

463019154515187598605230639025154515

48035

A200 -REV A

A200 -REV A

B200 -REV A

B200 -REV A

C201 -REV A

C201 -REV A

D201 -REV A

D201 -REV A

4 m²

Paraplegicfloor tiles

baby change

wc

whb

wh

bw

hb

ur

ur

wc

wc wc

whb

wc wc wc wc

whb whb whb

whb whbur

ur

wc

wc

wc

wc

wc

whb

whb

whb

E202 -REV A

E202 -REV A

280

2875

280

4240

345

1835

280

1965

115

1570

230

2690

230

2400

230

4700

230

5600

115

2360

115

2800

115

2800

115

2800

115

2800

345

D02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W03

W01 W01 W01 W01 W01 W01 W01 W01

W02 W02 W02 W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W01

W01

W01

W01

W01

W01

W01

W02W02W02W02

W02W02W02

W02

W02

W02

W02

W02

W02

28 m²

Patiofloor tiles

5 m²

Patiofloor tiles

3 m²

Patiofloor tiles

38 m²

Patiofloor tiles

37 m²

Patiofloor tiles

D02 D03 D04 D04

D03D03D03 D01

D04

D03

D03

D03

D05

D07

D06

D05

D07

D07

D07

D03

D01

D03

D03

D02

D12D09D08

D06

D06

D05D05

D07

D07

D07 D07 D07 D07

D09

D04

D04D03

D03

D12

D03

D01

D03

kitch

en

cabin

ets

to

deta

ils

serv

ice h

atc

h t

o

door

sch

edu

le

Refer to fixed joinery drawings for details on all vanities.

Refer to fixed joinery drawings for details on all vanities.

kitch

en

cabin

ets

to

deta

ils

AL05

AL10

AL02

AL03

AL01

AL04

AL08

AL09

AL12

AL07

AL07

AL07

AL07

AL07

AL07

AL07

AL06

AL11

D11

280

2875

230

4650

230

1590

280850115

2685

230

1585

230875230

2400

230

3620

230

1800

230

1985

230

3300

115

11500

280

1375

345

280

2875

280

6420

280

2000

230

1420

230

1585

230

3505

230

3620

230

4015

230

3300

115

11500

280

1375

345

280

2875

230

6470

280

1700

115

1835

230

9170

230

4015

230

2560

280945

345

1240

9545

280

1720

3435

6420

34720

44575

280 2800 230 2000 230 3745 230

400

280 3475 280 6110 230 5000 280 2750 115 2700 115 3900 2105 6085 345 4400 280

280 900 115 1785 230 2000 230 850115850115850115850 230 1590 280 8675 230 5000 280 9580 230 1645 230 6315 115 4400 280

280 2800 230 1255 230 1800 230 4280 280 8675 230 5000 280 9580 230 1645 230 4285 230 1800 115 4400 280

502581908075678563404035500549101185

48365

280

2875

230

4290

345

3000

115

2685

115

2700

115

2700

115

5765

115

2800

115

3470

115

3500

115

8670

345

280

2875

230

4290

345

1885

230885115

2685

115

2700

115

2700

115

5765

115

2800

115

3470

115

3500

115

5760

280

2630

345

280

10890

345

2270

230

5270

280

3735

115

1800

230

4270

230

5770

230

2930

230

3470

280

1375

345

7675

35180

1720

44575

2804400280158528042852801595230230023023002304520280500028061102802185280444511516352804400280

280 4400 115 6360 280 8575 280 5000 280 9580 230 1645 230 1700 115 2470 280 1750 115 4400 280

280 4400 115 1800 230 4330 280 2185 280 6110 280 5000 280 4520 230 2300 230 2300 230 1645 230 1800 230 925 230 1100 280 1750 115 4400 280

48365

500230

1500

230

9175

255

3620

230

1800

230

2400

230

1640

280

2475

115900230

2000

230900115900115900230

3470

280

1375

345

280

2875

230

7785

345

2270

230

5270

280

2820

230

685

115

1800

230

6000

280

1700

115

1835

230

1585

230

3505

230

3620

230

1800

230

1985

230

3300

115

11500

280

1375

345

10400

230

9170

230

1800

230

4775

280

2530

4285 230 1000 230 1200 230 770 230 2700 230 8675 230 14860 230 1645 230 2855 230 1200 230 1800 115 4400

139052304330230180023012552302800

reception desk to joinery details

secu

rity

cou

nte

r desk join

ery

deta

ils

steel shelving to details. ref. dwg no:

steel shelving to details. ref. dwg no:

steel shelving to details. ref. dwg no:

sin

k

58

Cir

cu

lati

on

Are

afloor

tile

s

7675

500

2995

8115

10660

1845

11065

1720

N

8 m²

Baby changingfloor tiles

Concrete apron to fall away from building as per eng. details

Co

ncre

te a

pro

n t

o f

all

aw

ay f

rom

bu

ildin

g a

s p

er

eng

. d

eta

ils

Co

ncre

te a

pro

n t

o f

all

aw

ay f

rom

bu

ildin

g a

s p

er

eng

. d

eta

ils

Co

ncre

te a

pro

n t

o f

all

aw

ay f

rom

bu

ildin

g a

s p

er

eng

. d

eta

ils

Co

ncre

te a

pro

n t

o f

all

aw

ay f

rom

bu

ildin

g a

s p

er

eng

. d

eta

ils

Co

ncre

te a

pro

n t

o f

all

aw

ay f

rom

bu

ildin

g a

s p

er

eng

. d

eta

ils

Concrete apron to fall away from building as per eng. details

Concrete apron to fall away from building as per eng. details

Concrete apron to fall away from building as per eng. details

Concrete apron to fall away from building as per eng. details

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

steel shelving to details. ref. dwg no:

steel shelving to details. ref. dwg no:

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Finishes as per finishing schedule

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Lin

e o

f ro

of

abo

ve

Line of roof above

Line of roof above

Line of roof above

Line of roof above

Line of roof above

be

am

@2

80

5 t

o

en

gin

ee

r's s

pec

beam above to engineer's spec

be

am

@2

80

5

to e

ng

inee

r's

sp

ec

beam above to engineer's spec

beam above to engineer's spec

be

am

ab

ove t

o e

ng

inee

r's s

pe

c

canopy above to engineer's spec

Concrete column as per engineers details

Concrete roof as per engineers details

Co

ncre

te r

oof

as p

er

en

gin

ee

rs d

eta

ils

Concrete roof as per engineers details

Glass Curtainwall system fixed to aluminiun column

Gla

ss C

urt

ain

wall

syste

m

fixe

d t

o a

lum

iniu

n c

olu

mn

AL13

AL14

Concrete column as per engineers details

beam @2805 to engineer's spec

beam @2805 to engineer's spec

NEW FIRE DOOR

beam above to engineer's spec

be

am

ab

ove

to e

ng

inee

r's

sp

ec

AL13

D08

FHR

D08

230 400230

ur

STEEL column as per engineers details

beam @2805 to engineer's

spec

2101 -

REV A

BABY CHANGE SPEC: Koala stainless steel clad surface mounted horizontal baby changing station with polyethylene interior. Full length steel-on-steel hinges with 11 gauge steel mounting bracket eliminating plastic wear points and providing superior child protection and durability. Gas spring mechanism ensures smooth open and close. Built-in liner cavity and two bag hooks. Includes child safety straps. Bed surface exclusively contains Microban® antimicrobial, reducing odor causing bacteria. ASTM compliant. Meets ADA requirements when mounted properly. Liner dispenser holds 15 liners. Constructed with 55% recycled materials; contributes to LEED certified building requirements.

D10

8675

6590

50x50x5mm Steel Tubing Screen Wall fixed to steel column @150mm c/c spacing, to

receive paint finish by specialist

2301200

D8

DB

D01NEW DUCT

1590

D01

1 : 100

GROUND FLOOR PLAN

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 100

2020/01/20 15:49:28

Designer

GROUND FLOOR PLAN

PROPOSED NEW OFFICES FORLIMPOPO DEPT. OF SOCIAL

DEVELOPMENTTSHILWAVHUSIKU SITE

100 - REV B

Author

Checker

18/KMS/102

B

29.1

1.20

19 1. 2 X NEW FIRE DOORS AT CIRCULATION AREA2. NEW GLASS DOUBLE DOOR AT GRID 103. NEW DUCT AT CIRCULATION AREA

Page 3: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

LOWER ROOF LEVEL3060

ROOF PLAN5185

GROUND FLOOR PLAN0

FGHIJKL

3060

2400

3685

425046755185

6205

Archive Battery Bank RM Play Room Waiting Area Circulation Area

foundations to engs details and spec

waterproof membraneto engs details and spec

230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4

Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details

Reinforced foundation walls to Structural Eng's details

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series

Reinforced foundation walls to Structural Eng's details

foundations to engs details and spec

foundations to engs details and spec

foundations to engs details and spec

foundations to engs details and spec

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

Reinforced foundation walls to Structural Eng's details

waterproof membraneto engs details and spec

230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4

230mm thick Brickwall Type 6.2including wall Type 6.5 with an external skin finish Type 7.4

Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details

Concrete roof slab Type 11 to Structural Engineering details.

LOWER ROOF LEVEL3060

ROOF PLAN5185

GROUND FLOOR PLAN0

ABCDE

2400

3060

3685

425046755185

6205

2805

255

Consulting OfficeOffice Open plan

250um polyethylene waterproofing membrane sheeting laid in accordance with

manufacturer's specification

230mm brick wall consisting of inner leaf stock brick and outer leaf face brick bedded in 6:1 cement mortar with birckforce every fourth course. Finished with 4:1 cement plaster, rhinoglide and paint (elsewhere specified) internally. Facebrick to be cleaned

Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details

Extra hard-baked clay bricks laid in strecher bond

with brickforce every second course and bedded

in 6:1 cement mortar

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

Suspended Acoustic ceiling Type 9.4 refer to ceiling

layouts 400 series

Reinforced foundation walls to Structural Eng's details Strip footings as per engineer's

design and specs Provide for the casting and testing of concrete test

cubes as per engineer's requirements

Suspended Acoustic ceiling Type 9.4 refer to ceiling

layouts 400 series

230mm brick wall consisting of inner leaf stock brick and outer leaf face brick bedded in 6:1 cement mortar with birckforce every fourth course. Finished with 4:1 cement plaster, rhinoglide and paint (elsewhere specified) internally. Facebrick to be cleaned

SA Pine Roof trusses as per engineers details and specifications installed onto 114x38 wall plate. Shop drawings to be submitted for approval.

Floor finish as per finishing schedule

Strip footings as per engineer's design and specs Provide for the

casting and testing of concrete test cubes as per engineer's requirements

Strip footings as per engineer's design and specs Provide for the

casting and testing of concrete test cubes as per engineer's requirements

Filling compacted in layers to engineer's specifications provide for

the testing of compaction

5.0

Circulation Area

3.1

375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.

375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.

3.2

3.2 3.2

3.2

3.2

3.2

3.2

3.1 3.13.1

1.1 Earthworks and levels: All siteworks and levels according to civil engineers details.1.2 Paving 1:Approved 65mm interlocking pavers laid as per engineers details and specs

Construction Notes:

The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)

2.1 Column FootingsColumn footing as per engineer's design and specs provide for the casting and testing of concrete test cubes as per engineer's requirements2.2 Concrete strip foundation footings:Strip footings as per engineer's design and specsProvide for the casting and testing of concrete test cubes as per engineer's requirements 2.3 Foundation walls: Extra hard-baked clay bricks laid in strecher bond with brickforce every second course and bedded in 6:1 cement mortar

3.1 Filling:Filling compacted in layers to engineer's specifications provide for the testing of compaction3.2 Insect poison:Applied to foundation trenches and filling in accordance with sabs 1164 / 1165 by specialist. a certificate of guarantee (covering 10 years) to be issued by applicator.

4.1 DPM:250um polyethylene waterproofing membrane sheeting laid in accordance with manufacturer's specification4.2 Surface Bed:125mm 15mpa Reinforced concrete surface bed cast in sections and cut through and casted around columns all in accordance with engineers details and specifications.4.3 Screed:3:1 Cement screed laid on clean surface: overall thickness of screed and floor finish: 25mm (see finishes: floor) where no finish, screed to be finished off smooth with a steel trowel.4.4 Concrete ApronConcrete apron as per engineers details and specifications.

5.1 Grano:40mm thick untinted Granolithic finish composed of one part cement, one part fine sand, two parts coarse sand and one part 5mm exposed granite particles, laid by specialist in panels not exceeding 10m2. including approved brass dividing strips, Floated with a steel trowel to perfectly smooth surface, free from bumps and scratches, and sealed with approved durable surface coat.5.2 Porcelain Tiles:600x600x8mm Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p).

6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.5.3 Porcelain Tiles:600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p). 6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.

6.1 DPC:375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.6.2 Stock brick:Baked clay bricks in stretcher bond with brickforce every fourth course and bedded in 6:1 cement mortar.6.3 Facebrick Appproved FBX clay facebrick laid in common bond to comply with SABS 227 and forming part of structure.6.5 Internal PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled

6.7 Exterior PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled6.8 Pre-cast lintelsStandard pre-stressed concrete lintel bedded in mortar and extending not less than 225mm on either side of opening. where openings exceed 3000mm in width, 2x12mm reinforcing rods per course (for 230mm wall) and 3x12mm reinforcing rods per course (for 345mm wall) to be laid in 3:1 mortar every course for 4 courses above lintels.6.9 Interior window sills:15mm thick cement window sill firmly bedded in 4:1 cement mortar, slightly projecting 10mm from wall edge and to be tucked below the window frame.10.0 Exterior window sills:Brick-on-edge with wood float plaster to a minimum 12mm 4:1 mixture cement plaster with DPC laid under as per 6.1

7.1 Existing Facebrick Clean and seal the facebrick.Use bucket and brush face brick cleaning method. Clean face brick wall, remove all smudges, seal all holes with the mortar which matches the existing mortar on the wall. Care must be exercised in selecting the proper cleaning solution for the job by getting brick manufacturers' recommendation.

7.2 Exterior Paint:emulsion paint on universal undercoats to exterior new cement plaster (NW 140). Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale - 8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years - inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. exterior quality to be used for exterior work 7.3 Interior Paint (PVA Acrylic):emulsion paint on universal undercoats to exterior new cement plaster. Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale -8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years -inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. interior quality to be used for interior work

7.4 Textured plaster:12mm cement plaster to recieve MARMORAN strictly in accordance with manufacturer's specifications.7.5 Halfbody Porcelain Tiles:Half body 600x300mm porcelain tiles laid in true straight, vertical and horizontal 2mm joints, including patent stainless steel corner stirps; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Finish off joints with grout in accordance with PW 371-A 12.1 (p and q) and SANS 10107. Colour to architects' approval.7.6 Marble tiles:600x600x20mm marble tiles laid in true straight, vertical and horizontal butt jointed, including patent stainless steel corner stirps.; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Colour to architects' approval7.7 Skirting:600mm wide x 100mm high x 8mm thick matt porcelain tile to comply with SABS 1449 laid on approved adhesives and grout in strict compliance to manufacturers instructions and SABS specification. Complete with corner and top stainless steel trims. Colour to architects' approval.

8.1 ColumnsConcrete columns as per engineer details and specifications.8.2 Concrete Gutter600x340mm Concrete gutter as per engineers details and specifications.8.3 Concrete BeamConcrete beam as per engineers details and specifications8.4 Steel BeamSteel beam as per engineers details and specifications8.5 Steel ColumnSteel column as per engineers details and specifications

9.1 Ceiling type A (plasterboard)1200x2400x9.5mm gypsum tapered edged ceiling boards secured to 38x38mm pine brandering with Sharp Point Screws 35mm at maximum 150mm centres. Boards tightly butted together and installed with the longer side running perpendicular to the direction of brandering. The boards shall be installed with the shorter side joints staggered by at least 300mm and centered on ceiling framework. Boards shall be installed with printed side up and all joints to be taped and skimmed with 3mm patent lightweight plaster on the same day as boards have been erected and plaster shall be finished to smooth polished surface to ensure a smooth unblemished ceiling surface ceiling edged with coved cornice. Seal with a full coat of plaster primer and apply 2x coats of emulsion paint, in accordance with PW 371-A 9.1.2 (a-r) Joint strips to be installed in areas where ceiling is not plastered.

9.2 Ceiling type B (600x600 Vinyl)Biologically absorbable mineral wool ceiling

tiles, size 600x600x15mm thick with square edge and white vinyl finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions. 9.3 Ceiling type C (600x600 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x 600x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.9.4 Ceiling type D (600x1200 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x1200x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.

9.5 Ceiling type E (Concrete soffit)Underside of concrete slab to receive ripple paint Colour as per architect.9.6 Ceiling type F (Isoboard)12x7900x50mm isoboard high density thermal insulation boards with beveled and shiplap edges fixed to purling on the underside of the steel trusses9.7 Ceiling type G (Trap door)Trap door: Fibre cement 600x600x2mm with 38x38mm SA Pine surround and cross bracing to inside fit into 600x600mm frame constructed of 114x38 SA Pine fixed between trusses.

10.1 Trusses:Steel trusses per engineers design and specifications .10.2 Sheeting:Kliplok with chromadek finish roof sheets fixed to steel purlins per engineers design and specifications10.3 Flashings:Flashing as per manufacturer's details and specifications.10.4 Fascia:steel fascia in areas marked on the drawings as per manufacturer's details and specifications.10.5 Sheet Metal Gutters:Chromadek sheet metal gutter fixed to steel trusses in areas marked on drawings and according to manufactuers' details and specification.10.6 Downpipe 1:

∅100mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.

10.7 Downpipe 2:

∅160mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.10.8 CertificatesA certificate from the fixing contractor as well as a seperate certificate from the sheeting supplier must be submitted before final completion certificate will

11.1 Concrete slabConcrete slab as per structural engineers details and specifications.11.2 Screed:3:1 Cement Screed laid on clean surface with falls to fullbore outlets.11.3 Waterproofing:One layer of bitumen waterproofing membrane, with 75mm side laps and 100mm end laps and sealed to primed surface to falls and crossfalls by "torchfusion" . bitumen waterproofing to be applied on concrete which already has waterproof cement additives. Waterproofing to be installed by an approved manufacturer's contractor under a ten year guarantee.

7. Wall Finishes Cont.:7. Wall Finishes Cont.:

7. Wall Finishes:

6. Wall Construction:

5. Floor Finish Cont.: 8. Concrete/Steel Structure:

9. Ceiling:

9. Ceiling cont.: 9. Ceiling cont.:

10. Sheet Metal Roof:

10. Sheet Metal Roof cont.:

11. Concrete Roof:

5. Floor Finish:

4. Floor Construction:

3. Back Filling:

2. Foundations:

1. External Site works: 6. Wall Construction Cont.:

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/10/16 11:58:44

Designer

SECTIONS AA AND BB

LDSD DESIGN PROTOTYPES

200 -REV A

Author

Checker

18/KMS/102

1 : 50

SECTION AA

1 : 50

SECTION BB

Page 4: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

1.1 Earthworks and levels: All siteworks and levels according to civil engineers details.1.2 Paving 1:Approved 65mm interlocking pavers laid as per engineers details and specs

Construction Notes:

The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)

2.1 Column FootingsColumn footing as per engineer's design and specs provide for the casting and testing of concrete test cubes as per engineer's requirements2.2 Concrete strip foundation footings:Strip footings as per engineer's design and specsProvide for the casting and testing of concrete test cubes as per engineer's requirements 2.3 Foundation walls: Extra hard-baked clay bricks laid in strecher bond with brickforce every second course and bedded in 6:1 cement mortar

3.1 Filling:Filling compacted in layers to engineer's specifications provide for the testing of compaction3.2 Insect poison:Applied to foundation trenches and filling in accordance with sabs 1164 / 1165 by specialist. a certificate of guarantee (covering 10 years) to be issued by applicator.

4.1 DPM:250um polyethylene waterproofing membrane sheeting laid in accordance with manufacturer's specification4.2 Surface Bed:125mm 15mpa Reinforced concrete surface bed cast in sections and cut through and casted around columns all in accordance with engineers details and specifications.4.3 Screed:3:1 Cement screed laid on clean surface: overall thickness of screed and floor finish: 25mm (see finishes: floor) where no finish, screed to be finished off smooth with a steel trowel.4.4 Concrete ApronConcrete apron as per engineers details and specifications.

5.1 Grano:40mm thick untinted Granolithic finish composed of one part cement, one part fine sand, two parts coarse sand and one part 5mm exposed granite particles, laid by specialist in panels not exceeding 10m2. including approved brass dividing strips, Floated with a steel trowel to perfectly smooth surface, free from bumps and scratches, and sealed with approved durable surface coat.5.2 Porcelain Tiles:600x600x8mm Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p).

6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.5.3 Porcelain Tiles:600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p). 6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.

6.1 DPC:375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.6.2 Stock brick:Baked clay bricks in stretcher bond with brickforce every fourth course and bedded in 6:1 cement mortar.6.3 Facebrick Appproved FBX clay facebrick laid in common bond to comply with SABS 227 and forming part of structure.6.5 Internal PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled

6.7 Exterior PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled6.8 Pre-cast lintelsStandard pre-stressed concrete lintel bedded in mortar and extending not less than 225mm on either side of opening. where openings exceed 3000mm in width, 2x12mm reinforcing rods per course (for 230mm wall) and 3x12mm reinforcing rods per course (for 345mm wall) to be laid in 3:1 mortar every course for 4 courses above lintels.6.9 Interior window sills:15mm thick cement window sill firmly bedded in 4:1 cement mortar, slightly projecting 10mm from wall edge and to be tucked below the window frame.10.0 Exterior window sills:Brick-on-edge with wood float plaster to a minimum 12mm 4:1 mixture cement plaster with DPC laid under as per 6.1

7.1 Existing Facebrick Clean and seal the facebrick.Use bucket and brush face brick cleaning method. Clean face brick wall, remove all smudges, seal all holes with the mortar which matches the existing mortar on the wall. Care must be exercised in selecting the proper cleaning solution for the job by getting brick manufacturers' recommendation.

7.2 Exterior Paint:emulsion paint on universal undercoats to exterior new cement plaster (NW 140). Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale - 8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years - inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. exterior quality to be used for exterior work 7.3 Interior Paint (PVA Acrylic):emulsion paint on universal undercoats to exterior new cement plaster. Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale -8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years -inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. interior quality to be used for interior work

7.4 Textured plaster:12mm cement plaster to recieve MARMORAN strictly in accordance with manufacturer's specifications.7.5 Halfbody Porcelain Tiles:Half body 600x300mm porcelain tiles laid in true straight, vertical and horizontal 2mm joints, including patent stainless steel corner stirps; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Finish off joints with grout in accordance with PW 371-A 12.1 (p and q) and SANS 10107. Colour to architects' approval.7.6 Marble tiles:600x600x20mm marble tiles laid in true straight, vertical and horizontal butt jointed, including patent stainless steel corner stirps.; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Colour to architects' approval7.7 Skirting:600mm wide x 100mm high x 8mm thick matt porcelain tile to comply with SABS 1449 laid on approved adhesives and grout in strict compliance to manufacturers instructions and SABS specification. Complete with corner and top stainless steel trims. Colour to architects' approval.

8.1 ColumnsConcrete columns as per engineer details and specifications.8.2 Concrete Gutter600x340mm Concrete gutter as per engineers details and specifications.8.3 Concrete BeamConcrete beam as per engineers details and specifications8.4 Steel BeamSteel beam as per engineers details and specifications8.5 Steel ColumnSteel column as per engineers details and specifications

9.1 Ceiling type A (plasterboard)1200x2400x9.5mm gypsum tapered edged ceiling boards secured to 38x38mm pine brandering with Sharp Point Screws 35mm at maximum 150mm centres. Boards tightly butted together and installed with the longer side running perpendicular to the direction of brandering. The boards shall be installed with the shorter side joints staggered by at least 300mm and centered on ceiling framework. Boards shall be installed with printed side up and all joints to be taped and skimmed with 3mm patent lightweight plaster on the same day as boards have been erected and plaster shall be finished to smooth polished surface to ensure a smooth unblemished ceiling surface ceiling edged with coved cornice. Seal with a full coat of plaster primer and apply 2x coats of emulsion paint, in accordance with PW 371-A 9.1.2 (a-r) Joint strips to be installed in areas where ceiling is not plastered.

9.2 Ceiling type B (600x600 Vinyl)Biologically absorbable mineral wool ceiling

tiles, size 600x600x15mm thick with square edge and white vinyl finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions. 9.3 Ceiling type C (600x600 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x 600x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.9.4 Ceiling type D (600x1200 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x1200x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.

9.5 Ceiling type E (Concrete soffit)Underside of concrete slab to receive ripple paint Colour as per architect.9.6 Ceiling type F (Isoboard)12x7900x50mm isoboard high density thermal insulation boards with beveled and shiplap edges fixed to purling on the underside of the steel trusses9.7 Ceiling type G (Trap door)Trap door: Fibre cement 600x600x2mm with 38x38mm SA Pine surround and cross bracing to inside fit into 600x600mm frame constructed of 114x38 SA Pine fixed between trusses.

10.1 Trusses:Steel trusses per engineers design and specifications .10.2 Sheeting:Kliplok with chromadek finish roof sheets fixed to steel purlins per engineers design and specifications10.3 Flashings:Flashing as per manufacturer's details and specifications.10.4 Fascia:steel fascia in areas marked on the drawings as per manufacturer's details and specifications.10.5 Sheet Metal Gutters:Chromadek sheet metal gutter fixed to steel trusses in areas marked on drawings and according to manufactuers' details and specification.10.6 Downpipe 1:

∅100mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.

10.7 Downpipe 2:

∅160mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.10.8 CertificatesA certificate from the fixing contractor as well as a seperate certificate from the sheeting supplier must be submitted before final completion certificate will

11.1 Concrete slabConcrete slab as per structural engineers details and specifications.11.2 Screed:3:1 Cement Screed laid on clean surface with falls to fullbore outlets.11.3 Waterproofing:One layer of bitumen waterproofing membrane, with 75mm side laps and 100mm end laps and sealed to primed surface to falls and crossfalls by "torchfusion" . bitumen waterproofing to be applied on concrete which already has waterproof cement additives. Waterproofing to be installed by an approved manufacturer's contractor under a ten year guarantee.

7. Wall Finishes Cont.:7. Wall Finishes Cont.:

7. Wall Finishes:

6. Wall Construction:

5. Floor Finish Cont.: 8. Concrete/Steel Structure:

9. Ceiling:

9. Ceiling cont.: 9. Ceiling cont.:

10. Sheet Metal Roof:

10. Sheet Metal Roof cont.:

11. Concrete Roof:

5. Floor Finish:

4. Floor Construction:

3. Back Filling:

2. Foundations:

1. External Site works: 6. Wall Construction Cont.:

LOWER ROOF LEVEL3060

GROUND FLOOR PLAN0

5 6 7 8 9

UPPER ROOF PLAN4675

2400

3060

3685

425046755185

6205

Head Of Facilities Circulation Area Screening

foundations to engs details and spec

waterproof membraneto engs details and spec

230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4

Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details

Reinforced foundation walls to Structural Eng's detailsFloor finish Type 5.2 including

approved adhersive on cement sand screed Type 4.3 on reinforced

concrete slab to S.E details

Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series

Reinforced foundation walls to Structural Eng's details

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

waterproof membraneto engs details and spec

230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4

foundations to engs details and spec

foundations to engs details and spec

Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series

LOWER ROOF LEVEL3060

ROOF PLAN5185

GROUND FLOOR PLAN0

FGHIJK

UPPER ROOF PLAN4675

2400

3685

3060

425046755185

6205

Multi-purpose Hall

foundations to engs details and spec

waterproof membraneto engs details and spec

230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4

Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details

Reinforced foundation walls to Structural Eng's details

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series

Reinforced foundation walls to Structural Eng's details

foundations to engs details and spec

foundations to engs details and spec

conc upstand to engs details and spec

Concrete roof slab Type 11 to Structural Engineering details.

4mm fully torched waterproofing as specified laid on screeds laid

to falls to roof outlets as per engs layouts

3620

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/10/16 11:58:46

Designer

SECTION CC AND DD

LDSD DESIGN PROTOTYPES

201 -REV A

Author

Checker

18/KMS/102

1 : 50

SECTION CC

1 : 50

SECTION DD

Page 5: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

1.1 Earthworks and levels: All siteworks and levels according to civil engineers details.1.2 Paving 1:Approved 65mm interlocking pavers laid as per engineers details and specs

Construction Notes:

The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)

2.1 Column FootingsColumn footing as per engineer's design and specs provide for the casting and testing of concrete test cubes as per engineer's requirements2.2 Concrete strip foundation footings:Strip footings as per engineer's design and specsProvide for the casting and testing of concrete test cubes as per engineer's requirements 2.3 Foundation walls: Extra hard-baked clay bricks laid in strecher bond with brickforce every second course and bedded in 6:1 cement mortar

3.1 Filling:Filling compacted in layers to engineer's specifications provide for the testing of compaction3.2 Insect poison:Applied to foundation trenches and filling in accordance with sabs 1164 / 1165 by specialist. a certificate of guarantee (covering 10 years) to be issued by applicator.

4.1 DPM:250um polyethylene waterproofing membrane sheeting laid in accordance with manufacturer's specification4.2 Surface Bed:125mm 15mpa Reinforced concrete surface bed cast in sections and cut through and casted around columns all in accordance with engineers details and specifications.4.3 Screed:3:1 Cement screed laid on clean surface: overall thickness of screed and floor finish: 25mm (see finishes: floor) where no finish, screed to be finished off smooth with a steel trowel.4.4 Concrete ApronConcrete apron as per engineers details and specifications.

5.1 Grano:40mm thick untinted Granolithic finish composed of one part cement, one part fine sand, two parts coarse sand and one part 5mm exposed granite particles, laid by specialist in panels not exceeding 10m2. including approved brass dividing strips, Floated with a steel trowel to perfectly smooth surface, free from bumps and scratches, and sealed with approved durable surface coat.5.2 Porcelain Tiles:600x600x8mm Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p).

6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.5.3 Porcelain Tiles:600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p). 6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.

6.1 DPC:375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.6.2 Stock brick:Baked clay bricks in stretcher bond with brickforce every fourth course and bedded in 6:1 cement mortar.6.3 Facebrick Appproved FBX clay facebrick laid in common bond to comply with SABS 227 and forming part of structure.6.5 Internal PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled

6.7 Exterior PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled6.8 Pre-cast lintelsStandard pre-stressed concrete lintel bedded in mortar and extending not less than 225mm on either side of opening. where openings exceed 3000mm in width, 2x12mm reinforcing rods per course (for 230mm wall) and 3x12mm reinforcing rods per course (for 345mm wall) to be laid in 3:1 mortar every course for 4 courses above lintels.6.9 Interior window sills:15mm thick cement window sill firmly bedded in 4:1 cement mortar, slightly projecting 10mm from wall edge and to be tucked below the window frame.10.0 Exterior window sills:Brick-on-edge with wood float plaster to a minimum 12mm 4:1 mixture cement plaster with DPC laid under as per 6.1

7.1 Existing Facebrick Clean and seal the facebrick.Use bucket and brush face brick cleaning method. Clean face brick wall, remove all smudges, seal all holes with the mortar which matches the existing mortar on the wall. Care must be exercised in selecting the proper cleaning solution for the job by getting brick manufacturers' recommendation.

7.2 Exterior Paint:emulsion paint on universal undercoats to exterior new cement plaster (NW 140). Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale - 8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years - inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. exterior quality to be used for exterior work 7.3 Interior Paint (PVA Acrylic):emulsion paint on universal undercoats to exterior new cement plaster. Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale -8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years -inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. interior quality to be used for interior work

7.4 Textured plaster:12mm cement plaster to recieve MARMORAN strictly in accordance with manufacturer's specifications.7.5 Halfbody Porcelain Tiles:Half body 600x300mm porcelain tiles laid in true straight, vertical and horizontal 2mm joints, including patent stainless steel corner stirps; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Finish off joints with grout in accordance with PW 371-A 12.1 (p and q) and SANS 10107. Colour to architects' approval.7.6 Marble tiles:600x600x20mm marble tiles laid in true straight, vertical and horizontal butt jointed, including patent stainless steel corner stirps.; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Colour to architects' approval7.7 Skirting:600mm wide x 100mm high x 8mm thick matt porcelain tile to comply with SABS 1449 laid on approved adhesives and grout in strict compliance to manufacturers instructions and SABS specification. Complete with corner and top stainless steel trims. Colour to architects' approval.

8.1 ColumnsConcrete columns as per engineer details and specifications.8.2 Concrete Gutter600x340mm Concrete gutter as per engineers details and specifications.8.3 Concrete BeamConcrete beam as per engineers details and specifications8.4 Steel BeamSteel beam as per engineers details and specifications8.5 Steel ColumnSteel column as per engineers details and specifications

9.1 Ceiling type A (plasterboard)1200x2400x9.5mm gypsum tapered edged ceiling boards secured to 38x38mm pine brandering with Sharp Point Screws 35mm at maximum 150mm centres. Boards tightly butted together and installed with the longer side running perpendicular to the direction of brandering. The boards shall be installed with the shorter side joints staggered by at least 300mm and centered on ceiling framework. Boards shall be installed with printed side up and all joints to be taped and skimmed with 3mm patent lightweight plaster on the same day as boards have been erected and plaster shall be finished to smooth polished surface to ensure a smooth unblemished ceiling surface ceiling edged with coved cornice. Seal with a full coat of plaster primer and apply 2x coats of emulsion paint, in accordance with PW 371-A 9.1.2 (a-r) Joint strips to be installed in areas where ceiling is not plastered.

9.2 Ceiling type B (600x600 Vinyl)Biologically absorbable mineral wool ceiling

tiles, size 600x600x15mm thick with square edge and white vinyl finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions. 9.3 Ceiling type C (600x600 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x 600x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.9.4 Ceiling type D (600x1200 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x1200x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.

9.5 Ceiling type E (Concrete soffit)Underside of concrete slab to receive ripple paint Colour as per architect.9.6 Ceiling type F (Isoboard)12x7900x50mm isoboard high density thermal insulation boards with beveled and shiplap edges fixed to purling on the underside of the steel trusses9.7 Ceiling type G (Trap door)Trap door: Fibre cement 600x600x2mm with 38x38mm SA Pine surround and cross bracing to inside fit into 600x600mm frame constructed of 114x38 SA Pine fixed between trusses.

10.1 Trusses:Steel trusses per engineers design and specifications .10.2 Sheeting:Kliplok with chromadek finish roof sheets fixed to steel purlins per engineers design and specifications10.3 Flashings:Flashing as per manufacturer's details and specifications.10.4 Fascia:steel fascia in areas marked on the drawings as per manufacturer's details and specifications.10.5 Sheet Metal Gutters:Chromadek sheet metal gutter fixed to steel trusses in areas marked on drawings and according to manufactuers' details and specification.10.6 Downpipe 1:

∅100mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.

10.7 Downpipe 2:

∅160mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.10.8 CertificatesA certificate from the fixing contractor as well as a seperate certificate from the sheeting supplier must be submitted before final completion certificate will

11.1 Concrete slabConcrete slab as per structural engineers details and specifications.11.2 Screed:3:1 Cement Screed laid on clean surface with falls to fullbore outlets.11.3 Waterproofing:One layer of bitumen waterproofing membrane, with 75mm side laps and 100mm end laps and sealed to primed surface to falls and crossfalls by "torchfusion" . bitumen waterproofing to be applied on concrete which already has waterproof cement additives. Waterproofing to be installed by an approved manufacturer's contractor under a ten year guarantee.

7. Wall Finishes Cont.:7. Wall Finishes Cont.:

7. Wall Finishes:

6. Wall Construction:

5. Floor Finish Cont.: 8. Concrete/Steel Structure:

9. Ceiling:

9. Ceiling cont.: 9. Ceiling cont.:

10. Sheet Metal Roof:

10. Sheet Metal Roof cont.:

11. Concrete Roof:

5. Floor Finish:

4. Floor Construction:

3. Back Filling:

2. Foundations:

1. External Site works: 6. Wall Construction Cont.:

LOWER ROOF LEVEL3060

GROUND FLOOR PLAN0

F G

H I J K L

Level 263685

UPPER ROOF PLAN4675

2400

3060

3685

425046755185

6205

Office Open plan Consulting OfficeCirculation Area

waterproof membraneto engs details and spec

230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4

Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details

Reinforced foundation walls to Structural Eng's details

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series

Reinforced foundation walls to Structural Eng's details

foundations to engs details and spec

foundations to engs details and spec

foundations to engs details and spec

Floor finish Type 5.2 including approved adhersive on cement

sand screed Type 4.3 on reinforced concrete slab to S.E details

waterproof membraneto engs details and spec

Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/10/16 11:58:47

Designer

SECTION EE

LDSD DESIGN PROTOTYPES

202 -REV A

Author

Checker

18/KMS/102

1 : 50

SECTION EE

Page 6: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

LOWER ROOF LEVEL

3060

ROOF PLAN

5185

GROUND FLOOR PLAN

0

A B C D E

F G H I J K L

2400

3060

3685

4250

4675

51856205

5702 - REV A

LOWER ROOF LEVEL

3060

ROOF PLAN

5185

GROUND FLOOR PLAN

0

ABCDE

FGHIJKL

2400

3060

3685

4250

4675

51856205

5702 - REV A

LOWER ROOF LEVEL

3060

ROOF PLAN

5185

GROUND FLOOR PLAN

0

1 2 4 5 6 7 8 9 10 113 12 13 14

2400

3060

3685

425051856205 9

701 - REV A

LOWER ROOF LEVEL

3060

ROOF PLAN

5185

GROUND FLOOR PLAN

0

124567891011 3121314

2400

3060

3685

4250

4675

51856205 9

701 - REV A

1 : 100

NORTH ELEVATION

1 : 100

SOUTH ELEVATION

1 : 100

WEST ELEVATION

1 : 100

EAST ELEVATIONClient

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 100

2019/10/16 11:58:52

Designer

ELEVATION

LDSD DESIGN PROTOTYPES

300 -REV A

Author

Checker

18/KMS/102

Page 7: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

9.3 CEILING TYPE C (ACOUSTIC)OWA SANDILE 600 x 1200 ( 15mm thk ) LAYING CEILING TILES ON A DONN EXPOSED GRID (T38) MAIN TEES AND T25 CROSS TEES WITH CAPPINGS OF PREPAINTED ALUMINIUM GRID SUSPENDED FROM CONCRETE SLAB OR TRUSSES WITH METAL HANGERS ALL AS PER MANUFACTURERS REQUIREMENTSCEILING EDGED WITH A PREPAINTED SHADOWLINE CORNICE

9.5 CEILING TYPE E UNDERSIDE OF CONCRETE SLAB TO RECEIVE RIPPLE PAINT COLOUR AS PER ARCHITECT.

CEILING LENGED:

9.1 CEILING TYPE A 9.5mm RHINO PLASTERBOARD TAPERED EDGED CEILING BOARDS SECURED TO A DONN SUSPENDED HIDDEN "T" STEEL GRID SYSTEM GRID SUSPENDED FROM CONCRETE SLAB WITH 25X25 METAL ANGLE HANGERS ALL AS PER MANUFACTURERS REQUIREMENTS BOARDS INSTALLED WITH PRINTED SIDE UP AND ALL JOINTS TO BE TAPED (RHINO TAPE) AND SCIMMED WITH RHINOLITE OR CRETESTONE PLASTER ALL DONE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS TO ENSURE A SMOOTH UNBLEMISHED CEILING SURFACE CEILING EDGED WITH A PREPAINTED SHADOWLINE CORNICE

9.4 CEILING TYPE D OWA SANDILE 1200 x 600 ( 15mm thk ) LAYING CEILING TILES ON A DONN EXPOSED GRID (T38) MAIN TEES AND T25 CROSS TEES WITH CAPPINGS OF PREPAINTED ALUMINIUM GRID SUSPENDED FROM CONCRETE SLAB OR TRUSSES WITH METAL HANGERS ALL AS PER MANUFACTURERS REQUIREMENTSCEILING EDGED WITH A PREPAINTED SHADOWLINE CORNICE

9.9 CEILING TYPE F LAMINATED POLYISOCYANURATE CORE BOARD WITH A MINIMUM OF 34KG/M3, THICKNESS OF 40mm; FACED WITH WHITE MINERAL LAMINATED ON BOTH SIDES IN WIDTHS OF 1220mm. OVER PURLIN TRUSS INSTALLATION TO BE FIXED IN STRICT ACCORDINCE TO MITEK DESIGN DETAILS

9.4 CEILING TYPE B GYPREX FISSURED 600 x 600 (12.5 mm thk)LAYING CEILING TILES ON A DONN EXPOSED GRID (T38) WITH CAPPINGS OF PREPAINTED ALUMINIUM GRID SUSPENDED FROM CONCRETE SLAB OR TRUSSES WITH METAL HANGERS ALL AS PER MANUFACTURERS REQUIREMENTSCEILIND EDGED WITH A PREPAINTED SHADOWLINECORNICE

TYPE E

A

A

11

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

J

J

K

K

L

L

22

44

55

66

77

88

99

1010

1111

33

1212

1313

1414

A200 -REV A

A200 -REV A

B200 -REV A

B200 -REV A

C201 -REV A

C201 -REV A

D201 -REV A

D201 -REV A

E202 -REV A

E202 -REV A

+2700

+2700

+2700

TYPE D

+2700

+2700

+2700

+2700

+2700

+2700

TYPE D

+2700

TYPE D

+2700+2700

+2700+2700+2700

+2700

+2700

+2700

TYPE D

+2700

+2700

+2700

+2700

+2700

+2700

+2700

+2700

+2700

+2700

+2700 +2700

+2700

+2700

+2700

+2700

3105

4635

2115

3880

5550

3850

2030

4500

1730

4270

3160

3700

1655

44180

46301915451518759860523063902515456020304515

48035

+2

10

0

TY

PE

A

+2400

TYPE B

+2400

TYPE B

+2400

TYPE B

+2400 +2400

+2400

+2400

+2400

TYPE B

+2700

+2805

+2700

TYPE E

TYPE E

TYPE E

TYPE F

+2400

TYPE B

+2400

TYPE B

+2400

TYPE B

TYPE A

TYPE A

TY

PE

A

+3230

TYPE C

+2700

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE DTYPE D

TYPE DTYPE DTYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE D

TYPE DTYPE D TYPE D

TYPE D

TYPE E

TYPE A

TYPE D

+2805

TYPE A

TYPE EClient

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

As indicated

2019/11/03 14:29:34

Designer

GROUND FLOOR CEILING PLAN

LDSD DESIGN PROTOTYPES

400 - REV A

Author

Checker

18/KMS/102

1 : 100

GROUND FLOOR PLAN

Page 8: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

J

J

K

K

L

L

1010

1111

Female

van

ity w

ash

han

d b

asin

ur

ur

wc

wc wc

whb

wc wc wc wc

vanity wash hand basin

SDSD

SD

Grab railTRH

TRH TRH TRH TRH

TRH

Male

Paraplegic

1200

70

1200

400

600

600280

50 1200

1200

70

D05

D07

D07

D06

D05

D07 D07 D07 D07

1

2

3

4

5

6

8

7

9

10

11

12

13

600

1570

2200

600

L

L

1010

wc

vanity whb

SD

TRH BABY CHANGING STATION

200 1200

600

590

D06

14

17

16

15

Baby changing

1400

600

L

vanity whb

Ceiling Type A

600 X 600mm skirting tiles to match Floor tiles

850

2100

2400

Male

300

600

200 X 600mm Porcelain wall tiles

GROUND FLOOR PLAN0

1011

vanity wash hand basin

850

2100 2400

Male mirror

soap dispenser

Ceiling Type A

300

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

wc

600

10 11

D05

ur urwc

TRH

600

2400

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

Male

GROUND FLOOR PLAN0

L

Level 232400

850

2100

2400

D07

ur vanity whb

600 X 600mm skirting tiles to match Floor tiles

600

200 X 600mm Porcelain wall tiles

Ceiling Type A

300

Male

L

wc

TRH

wc

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

TRH

W01 W01

Male 2400

600

11

Paraplegic

600 X 600mm skirting tiles to match Floor tiles

600

200 X 600mm Porcelain wall tiles

2400

wc

whb

TRH

Paraplegic WC Type S3.2

Ceiling Type 9.3

Internal wall finish Type 7.5

Soap Dispenser Type 6.5

Paraplegic wash-hand-basin set Type S2.2

Mirror Type 5.1

Floor finish Type 5.3

Side Grab Rail Type K4.9

Rear Grab Rail Type K4.8

mirror

SD

K

Paraplegic

W01 W01

wc

whb

600 X 600mm skirting tiles to match Floor tiles

600

200 X 600mm Porcelain wall tiles

2400

11

Paraplegic

600 X 600mm skirting tiles to match Floor tiles

600

200 X 600mm Porcelain wall tiles

2400

K

600

200 X 600mm Porcelain wall tiles

D06

600 X 600mm skirting tiles to match Floor tiles

Paraplegic

2400

1011

Female

wc

200 X 600mm Porcelain wall tiles

D05

600 X 600mm skirting tiles to match Floor tiles

2400

600

J

wc wc wc wc

W01 W01 W01 W01

TRH

2400

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

Female

600

10 11

Ceiling Type A

600 X 600mm skirting tiles to match Floor tiles

vanity whbTRH

wc

Female200 X 600mm Porcelain wall tiles

550

2100

2400

850

300

J

vanity wash hand basin

600

Ceiling Type A

mirror

Soap dispenser

2100

2400

200 X 600mm Porcelain wall tiles

600 X 600mm skirting tiles to match Floor tiles

Female

850

300

L

1100

Baby changing station @ 1100mm heightTRH

600 X 600mm skirting tiles to match Floor tiles

600

200 X 600mm Porcelain wall tiles

Baby changing

2400

Internal wall finish Type 7.5

Floor finish Type 5.3

Approved Baby change unit to specialists and conforming to latest SABS standards.

10

Baby changing station @ 1100mm height

200 X 600mm Porcelain wall tiles

600

600 X 600mm skirting tiles to match Floor tiles

2400

D06

Baby changing

L

Baby changingmirror

vanity whb

200 X 600mm Porcelain wall tiles

600 X 600mm skirting tiles to match Floor tiles

600

2400

300

850

Mirror Type 5.2

Soap Dispenser Type 6.5

Floor finish Type 5.3

Vanity wash-hand-basin Type S2.1

10

W03

wc

TRH

Soap dispenser

vanity whb

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

2400

Baby changing

600

300

850

1.1 Stainless Steel single end bowlStainless steel 1000x457mm inset single end bowl with recessed drainage ledge and folded edges. Bowl to be fitted to kitchen cupboard (cupboard elsewhere measured), Grade 304 (18/10) Stainless Steel sink to comply with SABS 906 fitted with: Approved hot and cold Sink mixer- wall type, chrome plated fixed Outlet, adjustable and supplied with suitable assesories in accordance to manufacturer’s specifications. Sink installation height = 900mm AFFL.

SANITARY SPECIFICATIONS:

The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)

4.1 VANITY BASIN:490x310mm Under counter Basin without tap hole but with overflow complete with mounting kit

4.2 PARAPLEGIC BASIN:490mm Ceramic rectangular wall mounted basin with one taphole configuration and concealed brackets, including 12mm C.P. lever action pillar tap with ceramic disks.

4.3 510x405mm basin with tap hole and overflow and pedestal

2.1 Floor standing wash down close coupled dual flush toilet complete with toilet, cistern, push botton acuator, pan, seat, float value and flush valve

2.2 Ceramic Paraplegic semi-close coupled 90° outlet open rim washdown pan and matching 9 litre cistern complete with lid, fitments, and purpose made C.P. right side-flush lever, complete with purpose made thermoset seat and cover plate

2.3 Junior free standing wc floor standing wash down closw coulpeddual flush toilet cistern, push botton acuator, pan, seat, float value and flush valve

7.1 BASIN MIXER:Single lever basin mixer complete withpop-up waste, mounting kit, 1/2" female flexible inlets including alternative flow straighterfor low pressure installation

7.2 SINK MIXER:Wall type sink mixer complete with aerated swivel outlet and concealed connections

7.3 ELBOW ACTION MIXER:Medical pillar mixer with aerated swan neck swivel outlet

2. WC PAN: 4. BASIN AND TAPS1. SINK 5. MIRROR:

6.1 TOILET ROLL HOLDERstainless steel toilet roll holders, size 304x156x140,7mm deep for 2 rolls maximum 108mm diameter with spindle system and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.

6.2 WASTE BIN 1stainless steel sanitary towel disposal bins, size 304 x 205 x 134mm deep with capacity of 6 litres, plugged and screwed to the wall with stainless steel screws.

6.3 WASTE BIN 2stainless steel recessed waste disposal bins, size 396 x 270 x 520mm high, capacity of 45 litres and cylinder lock with standard

6.4 PAPER TOWEL DINSPENSERstainless steel paper towel dispenser, size 300 x 270 x 340mm high with a capacity of 300-400 towels and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.

6.5 SOAP DISPENSERstainless steel soap dispensers, size 304 x 100 x 134mm deep with a replaceable and refillable 1 litre container, cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.

6.6 AIR TOWELstainless steel automatic hands free hand dryer, size 284 x 202 x 248mm deep with 2 vandal proof lock screws and key wrench, plugged and screwed to the wall with stainless steel screws, 200 w motor connected to 230/240 volt power supply. with 5 year warranty.

6.7 GRAB RAIL (REAR)32mm diameter stainless steel rear grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.

6.8 GRAB RAIL (SIDE)32mm diameter stainless steel 300x300x300mm right hand side grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.

3.3 WALL HANG URINALBack entry urinal with intedral spreader and trap complete with urinal, outlet seal, inlet bung/seal, metal grating, hunger brackets and integral spreader

6mm Silver float glass copper backed mirrors with beveled edges, holed for and fixed with chromium plated dome capped mirror screws with bubber buffers to plugs in brick walls

5.1 600x1000mm MIRROR5.2 1200x1000mm MIRROR

3. URINAL: 6. OTHERS: 7. TAPS:

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/10/16 11:58:58

Designer

WET AREAS

LDSD DESIGN PROTOTYPES

510 - REV 00

Author

Checker

18/KMS/102

1 : 50

PUBLIC ABLUTIONS

1 : 50

BABY CHANGING ROOM

1 : 50

Elevation 11 : 50

Elevation 21 : 50

Elevation 3

1 : 50

Elevation 41 : 50

Elevation 5 1 : 50

Elevation 6

1 : 50

Elevation 71 : 50

Elevation 81 : 50

Elevation 9

1 : 50

Elevation 101 : 50

Elevation 11

1 : 50

Elevation 121 : 50

Elevation 13

1 : 50

Elevation 141 : 50

Elevation 15

1 : 50

Elevation 16 1 : 50

Elevation 17

Page 9: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

C

C

D

D

44

55

66

33

ur

ur

wc

wc

wc

wc

wc

whb

Female

Paraplegic

Male

Circulation Area

125

1200

1820

1200

600

600

280

1501800

vanity wash-hand-basin

SD

van

ity w

ash

-han

d-b

asin

SD

TRH

TRH

TRH

TRH

D07

D07

D07

D05

D06

D07D05

18

19

20

21

22

23

24

25

26

27

28

29

30

1500

600

600

1700

CD

Female

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles Ceiling Type A

300

vanity whbTRH

wc

2100

2400

600

300

850

43

Female

Vanity wash hand basin

soap dispenser

mirror

300

300

600

Ceiling Type A

2100

2400

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

850

C D

Female

600

D05

wc

200 X 600mm Porcelain wall tiles

600 X 600mm skirting tiles to match Floor tiles

2400

4 3

Female200 X 600mm Porcelain wall tiles

wc wc wc

TRH TRH TRH

W01 W01 W01

2400

600 X 600mm skirting tiles to match Floor tile

600

D

Paraplegic

600

600 X 600mm skirting tiles to match Floor tile

2400

200 X 600mm Porcelain wall tiles

4

D06

Paraplegic

2400

200 X 600mm Porcelain wall tiles

600 X 600mm skirting tiles to match Floor tile

600

D

Paraplegic

600 X 600mm skirting tiles to match Floor tile

200 X 600mm Porcelain wall tiles

600

Grab rail

whb

wc

2400

4

W01 W01

Paraplegic

600wc

whb

2400

600 X 600mm skirting tiles to match Floor tile

200 X 600mm Porcelain wall tiles

Grab rail

D

2400

Male

wc

TRH

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

600

D

Male

D07 D05

2400

ur

200 X 600mm Porcelain wall tiles

600

600 X 600mm skirting tiles to match Floor tiles

5 6

Male

SD

vanity whb

2400

2100

300

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

300

850

600

D

Malemirror

300

Ceiling Type A

vanity wash hand basin

soap dispenser

ur

600 X 600mm skirting tiles to match Floor tiles

2100

2400

200 X 600mm Porcelain wall tiles

600

300

850

56

Male

wc

TRH

W01W01

ur ur

600 X 600mm skirting tiles to match Floor tiles

200 X 600mm Porcelain wall tiles

2400

600

K

K

L

L

99

10 m²

Archivefloor tiles

4285

2400

D09

A

D

C

B

KL

Archive

D09

01

01

02

02

04

03

03500

450

450

450

1914

9

Archive

01

01

02

02

02

04

03

03

500

450

450

450

K L

Archive

01

01

03

02

0203

03

02

04

1914

500

450

450

450

9

Archive

GENERAL NOTES:

01 TOPS:16mm THICK CHIPBOARD WITH LEADING EDGES. MELAMINE FINISH TO BOTH SIDES

02 BRACKETS:"SHELVIT" OR ANY OTHER APPROVED SYSTEM 03 ADJUSTABLE WALL

03 FIXING BRACKETS:"SHELVIT" OR ANY OTHER APPROVED SYSTEM, FIXED TO WALL AS PER MANUFACTURER'S SPECIFICATION

04 TOP RAIL:"SHELVIT" OR ANY OTHER APPROVED SYSTEM

NOTE: DESIGN MAY VARY ACCORDING TO DIFFERENT MANUFACTURER'S PRODUCTS

01

500

450

450

450

1914

02

01

02

04

03

03

1.1 Stainless Steel single end bowlStainless steel 1000x457mm inset single end bowl with recessed drainage ledge and folded edges. Bowl to be fitted to kitchen cupboard (cupboard elsewhere measured), Grade 304 (18/10) Stainless Steel sink to comply with SABS 906 fitted with: Approved hot and cold Sink mixer- wall type, chrome plated fixed Outlet, adjustable and supplied with suitable assesories in accordance to manufacturer’s specifications. Sink installation height = 900mm AFFL.

SANITARY SPECIFICATIONS:

The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)

4.1 VANITY BASIN:490x310mm Under counter Basin without tap hole but with overflow complete with mounting kit

4.2 PARAPLEGIC BASIN:490mm Ceramic rectangular wall mounted basin with one taphole configuration and concealed brackets, including 12mm C.P. lever action pillar tap with ceramic disks.

4.3 510x405mm basin with tap hole and overflow and pedestal

2.1 Floor standing wash down close coupled dual flush toilet complete with toilet, cistern, push botton acuator, pan, seat, float value and flush valve

2.2 Ceramic Paraplegic semi-close coupled 90° outlet open rim washdown pan and matching 9 litre cistern complete with lid, fitments, and purpose made C.P. right side-flush lever, complete with purpose made thermoset seat and cover plate

2.3 Junior free standing wc floor standing wash down closw coulpeddual flush toilet cistern, push botton acuator, pan, seat, float value and flush valve

7.1 BASIN MIXER:Single lever basin mixer complete withpop-up waste, mounting kit, 1/2" female flexible inlets including alternative flow straighterfor low pressure installation

7.2 SINK MIXER:Wall type sink mixer complete with aerated swivel outlet and concealed connections

7.3 ELBOW ACTION MIXER:Medical pillar mixer with aerated swan neck swivel outlet

2. WC PAN: 4. BASIN AND TAPS1. SINK 5. MIRROR:

6.1 TOILET ROLL HOLDERstainless steel toilet roll holders, size 304x156x140,7mm deep for 2 rolls maximum 108mm diameter with spindle system and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.

6.2 WASTE BIN 1stainless steel sanitary towel disposal bins, size 304 x 205 x 134mm deep with capacity of 6 litres, plugged and screwed to the wall with stainless steel screws.

6.3 WASTE BIN 2stainless steel recessed waste disposal bins, size 396 x 270 x 520mm high, capacity of 45 litres and cylinder lock with standard

6.4 PAPER TOWEL DINSPENSERstainless steel paper towel dispenser, size 300 x 270 x 340mm high with a capacity of 300-400 towels and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.

6.5 SOAP DISPENSERstainless steel soap dispensers, size 304 x 100 x 134mm deep with a replaceable and refillable 1 litre container, cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.

6.6 AIR TOWELstainless steel automatic hands free hand dryer, size 284 x 202 x 248mm deep with 2 vandal proof lock screws and key wrench, plugged and screwed to the wall with stainless steel screws, 200 w motor connected to 230/240 volt power supply. with 5 year warranty.

6.7 GRAB RAIL (REAR)32mm diameter stainless steel rear grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.

6.8 GRAB RAIL (SIDE)32mm diameter stainless steel 300x300x300mm right hand side grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.

3.3 WALL HANG URINALBack entry urinal with intedral spreader and trap complete with urinal, outlet seal, inlet bung/seal, metal grating, hunger brackets and integral spreader

6mm Silver float glass copper backed mirrors with beveled edges, holed for and fixed with chromium plated dome capped mirror screws with bubber buffers to plugs in brick walls

5.1 600x1000mm MIRROR5.2 1200x1000mm MIRROR

3. URINAL: 6. OTHERS: 7. TAPS:

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/10/16 11:59:03

Designer

WET AREAS/SHELVING

LDSD DESIGN PROTOTYPES

511 - REV 00

Author

Checker

18/KMS/102

1 : 50

STAFF ABLUTIONS

1 : 50

Elevation 181 : 50

Elevation 191 : 50

Elevation 20

1 : 50

Elevation 211 : 50

Elevation 221 : 50

Elevation 231 : 50

Elevation 24

1 : 50

Elevation 25 1 : 50

Elevation 261 : 50

Elevation 271 : 50

Elevation 281 : 50

Elevation 291 : 50

Elevation 30

1 : 50

ARCHIVE 1 : 50

Elevation A1 : 50

Elevation B1 : 50

Elevation C1 : 50

Elevation D

Page 10: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

N

A

A

11

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

J

J

K

K

L

L

22

44

55

66

77

88

99

1010

1111

33

RO

OF

PIT

CH

RO

OF

PIT

CH

RO

OF

PIT

CH

3° ROOF PITCH

RO

OF

PIT

CH

RO

OF

PIT

CH

RO

OF

PIT

CH

RO

OF

PIT

CH

RO

OF

PIT

CH

RO

OF

PIT

CH

1212

1313

1414

A200 -REV A

A200 -REV A

B200 -REV A

B200 -REV A

C201 -REV A

C201 -REV A

D201 -REV A

D201 -REV A

E202 -REV A

E202 -REV A

3105

4635

2115

3880

5550

3850

2030

4500

1730

4270

3160

3700

1655

44180

46301915451518759860523063902515456020304515

48035

RO

OF

PIT

CH

NEW Concealed fix 0.55mm thick and 700mm cover width profile, colour to be confirmed, C.1.S finish with standard backing coat g550 interlocking roof sheeting. AZ100 spelter to both sides fixed to steel purlins as per engineer's specifications using clips, screw fixed to steel purlins secured with No. 10x16mm or 12x22mm wafer head self-tapping screws, all in accordance with manufacturer's recommendations and INSTALLED BY ACCREDITED INSTALLER.

1 : 100

ROOF PLAN

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 100

2019/10/16 11:59:08

Designer

ROOF PLAN

LDSD DESIGN PROTOTYPES

600 -REV 01

Author

Checker

18/KMS/102

Page 11: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

A

A

11

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

J

J

K

K

L

L

22

44

55

66

77

88

99

1010

1111

33

1212

1313

1414

A200 -REV A

A200 -REV A

B200 -REV A

B200 -REV A

C201 -REV A

C201 -REV A

D201 -REV A

D201 -REV A

E202 -REV A

E202 -REV A

Multi-purpose HallConsulting Office

Consulting Office

Sick Bay

In-take Screening

Cleaner Store

30 m²

Boardroomfloor carpet

Staff/Kitchen

Consulting Office

Consulting Office

Community Dev.Supr.

Com. Dev.Pract.

Circulation Area

Quiet/Obser.

Group/Interview

Suprv.Social Worker

Female

Male

Male Female

Paraplegic

Store Room

IT/ServerPrint Room

Registry

ArchivePlay Room

Store Room

Security

Consulting Office

Consulting Office

Consulting Office

Consulting Office

Admin Supp.

Head Of Facilities

Meeting Area

Meeting Area

Battery Bank RM

Stationary

Waiting Area

Office Open plan

Circulation Area

Office Open plan

OUTDOOR SEATING

Waiting Area

Reception

Library/Computer Lab

PLA

NT

ER

3105

4635

2115

3880

5550

3850

2030

4500

1730

4270

3160

3700

1655

44180

46301915451518759860523063902515456020304515

48035

Paraplegic

wc

whb

wh

bw

hb

ur

ur

wc

wc wc

whb

wc wc wc wc

whb whb whb

whb whbur

ur

wc

wc

wc

wc

wc

whb

whb

whb

D02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W03

W01 W01 W01 W01 W01 W01 W01 W01

W02 W02 W02 W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W02

W01

W01

W01

W01

W01

W01

W01

W02W02W02W02

W02W02W02

W02

W02

W02

W02

W02

W02

Patio

PatioPatio

Patio

Patio

D02 D03 D04 D04

D03D03D03 D01

D04

D03

D03

D03

D05

D07

D06

D05

D07

D07

D07

D03

D01

D03

D03

D02

D12D09D08

D06

D06

D05D05

D07

D07

D07 D07 D07 D07

D09

D04 D04

D03

D03

D12

D03

D01

D03

AL05

AL10

AL02

AL03

AL01

AL04

AL04

AL08

AL09

AL12

AL07

AL07

AL07

AL07

AL07

AL07

AL07

AL06

AL11

D11

sin

k

Circu

latio

n A

rea

N

Baby changing

5.2 Porcelain Tiles (Interior):600x600x8mm interior Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding.

5.3 Porcelain Tiles (Exterior):600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding.

TILE LEGEND:

5.4 Porcelain Tiles (Interior):300x600x8mm interior Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding.

550

1200

400 1200

2851200

1200

550

400600

420

1800

600455

4001200

1200

370

4001200

1200

285

4001200

600

200

4001200

4001200

285

600

600445

600645

1200

85

600600

85

1285

1330 540 600 600

580600

400 1200

600505

400 1200

1200120

400 1200

465 1200

380

1200

1200 150

600

150

400 1200

365

1200

1501200

610

300

600

380600

5101800

1200155

600 480

415600

1800

2290

600530

1200

600600

1200290

300

1200

1001800

300

1200

2301200

300

1200

1200

140

535 600

1200

1551200

400 1200

600

330

400 1200

400 1200

1701200

155

1800

400 1800

210

1200

3431200

885

3651200

885

1205

2851200

1200

9701 - REV A

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 100

2019/10/16 11:59:11

Designer

TILE LAYOUT

LDSD DESIGN PROTOTYPES

650 - REV 00

Author

Checker

18/KMS/102

1 : 100

GROUND FLOOR TILE LAYOUT

Page 12: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

2700

695 2190

2885

660

2400

1500104810481048104810481048

7785

3060

870 920 920 1560 920 920

6110

660

2400

3060

3060

2710

350

4300

2400

0

1590

2400

300

600

1800

920 920 920

2805

2760

WINDOW DESCRIPTION

WIN

DO

W S

CH

ED

UL

E

SC

AL

E 1

:50

FRAME PARTICULARS

GLAZING PARTICULARS

IRONMONGERY

W02

LOCATION OFFICESMALE / FEMALE /DISABLED ABLUTIONS

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

8.76mm THICK LAMINATED SAFETY GLASS IN ALL PANELS BELOW 900mm HEIGHT FROM FFL AND 6.38mm THICK GLASS IN ALL OTHER PANELS. GLAZING SHALL BE EXECUTED IN STRICT ACCORDANCE WITH THE NBR PART N SABS 10137 SABS 10400, SABS 1263 and AAAMSA SELECTION GUIDE for SAFETY.

ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

OBSCURED 8.76mm THICK LAMINATED SAFETY GLASS IN ALL PANELS BELOW 900mm HEIGHT FROM FFL AND 6.38mm THICK OBSCURED GLASS IN ALL OTHER PANELS. GLAZING SHALL BE EXECUTED IN STRICT ACCORDANCE WITH THE NBR PART N SABS 10137 SABS 10400, SABS 1263 and AAAMSA SELECTION GUIDE for SAFETY.

ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS

1200

1200

2400

900600

900

1500

2400

W01

WINDOW DESCRIPTION

AL

UM

INIU

M S

CH

ED

UL

E

SC

AL

E 1

:50

FRAME PARTICULARS

GLAZING PARTICULARS

IRONMONGERY

AL02

LOCATION MULTI-PURPOSE HALLMAIN ENTRANCE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

NONE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS

AL01

WINDOW DESCRIPTION

AL

UM

INIU

M S

CH

ED

UL

E

SC

AL

E 1

:50

FRAME PARTICULARS

GLAZING PARTICULARS

IRONMONGERY

AL04

LOCATION RECEPTIONMULTI-PURPOSE HALL

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

NONE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

NONE

AL03 AL05

PASSAGE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

NONE

AL06

OPEN PLAN OFFICES

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

NONE

01

02 01 01

0115 49

01

W03

BABY CHANGE

1200

1200

2400

900

01

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

OBSCURED 8.76mm THICK LAMINATED SAFETY GLASS IN ALL PANELS BELOW 900mm HEIGHT FROM FFL AND 6.38mm THICK OBSCURED GLASS IN ALL OTHER PANELS. GLAZING SHALL BE EXECUTED IN STRICT ACCORDANCE WITH THE NBR PART N SABS 10137 SABS 10400, SABS 1263 and AAAMSA SELECTION GUIDE for SAFETY.

ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS

HINGESDOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR

HINGESDOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOORDOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS

PER DOOR

ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS

ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2020/02/10 13:08:14

Designer

ALUMINIUM AND WINDOWSCHEDULE

PROPOSED NEW OFFICES FORLIMPOPO DEPT. OF SOCIAL

DEVELOPMENTTSHILWAVHUSIKU SITE

700 - REV B

Author

Checker

18/KMS/102

Page 13: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

WINDOW DESCRIPTION

AL

UM

INIU

M S

CH

ED

UL

E

SC

AL

E 1

:50

FRAME PARTICULARS

GLAZING PARTICULARS

IRONMONGERY

AL08

LOCATION WAITING AREACONSULTING OFFICES

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN CCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN CCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

AL07 AL09

STAFF ENTRANCE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

NONE

AL10

PLAY ROOM

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN CCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

01 01 0107

AL11

PASSAGE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE ANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN ACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

01

WINDOW DESCRIPTION

AL

UM

INIU

M S

CH

ED

UL

E

SC

AL

E 1

:50

FRAME PARTICULARS

GLAZING PARTICULARS

IRONMONGERY

LOCATION STAFF/KITCHEN

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

NONE

AL12

01

AL13

PASSAGE

01

AL14 AL19

QUIET/OBSERVER ROOM

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE ANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN ACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

0101

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.

HINGES

NONE NONE

DOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR

DOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR DOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR NONE NONE

900 900 900

2400

2700

2400

750 1500 750

3000

735 1450

2185

2400

2700

876 876 876 876

3505

2400

1595

2400

EQ EQ EQ EQ EQ EQ EQ EQ

5000

8000

2700

10933

2720

2000

2230

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/11/03 14:29:35

Designer

ALUMINIUM AND WINDOWSCHEDULE

LDSD DESIGN PROTOTYPES

701 - REV A

Author

Checker

18/KMS/102

Page 14: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

WINDOW DESCRIPTION

AL

UM

INIU

M S

CH

ED

UL

E

SC

AL

E 1

:50

FRAME PARTICULARS

GLAZING PARTICULARS

IRONMONGERY

AL16

LOCATION OFFICE OPEN PLANOFFICE OPEN PLAN

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN ACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

AL15 AL17

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

01 0101

WINDOW DESCRIPTION

AL

UM

INIU

M S

CH

ED

UL

E

SC

AL

E 1

:50

FRAME PARTICULARS

GLAZING PARTICULARS

IRONMONGERY

LOCATION MULTI-PURPOSE HALL

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

AL18

01

MULTI-PURPOSE HALL

RECEPTION AREA

PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.

EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL

ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137

NONE

AL20

03

8048

750

8475

1645

1201

7785

1424

961

5935

442

4300

1275

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/11/03 14:29:35

Designer

ALUMINIUM AND WINDOWSCHEDULE

LDSD DESIGN PROTOTYPES

702 - REV A

Author

Checker

18/KMS/102

Page 15: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

D01

FFL

DOOR DESCRIPTION

DO

OR

SC

HE

DU

LE

1

:50

FRAME PARTICULARS

IRONMONGERY

ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.

DOOR FINISH

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR: COLOUR TO ARCHITECT`S APPROVAL

FRAME FINISH

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:

POWDER COATED ALUMINIUM FRAME IN ACCORDANCE TO LATEST SABS STANDARDS. AND QUALITY PROCEDURES TO BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002.

GLAZING DOUBLE CLEAR SAFETY "GSA SMARTGLASS CLEARVUE" GLASS, GLAZED IN ACCORDANCE WITH NBF N SCHEDULE 1 AND SABS 0137.

HINGES 6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

D02

D08

D03 D04

LOCATION FIRE ESCAPE

ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:

POWDER COATED ALUMINIUM FRAME IN ACCORDANCE TO LATEST SABS STANDARDS. AND QUALITY PROCEDURES TO BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR:

DOUBLE CLEAR SAFETY "GSA SMARTGLASS CLEARVUE" GLASS, GLAZED IN ACCORDANCE WITH NBF N SCHEDULE 1 AND SABS 0137.

6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

STAFF/KITCHEN, MULTIPURPOSE HALL AND BOARDROOM

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:

ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR: BRONZE

POWDER COATED ALUMINIUM FRAME IN ACCORDANCE TO LATEST SABS STANDARDS. AND QUALITY PROCEDURES TO BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR: BRONZE

NONE

6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

FIRE/ DB CABINET

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:

40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

OFFICES, MEETING ROOM, PLAYROOM

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

STORES, CLEANER , IT/SERVER, STATIONARY ROOM

40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.-ACTUAL SIZE OF 300X300 ALUMINIUM DOOR GRILL TO MECHANICAL ENGINEER DETAILS

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

D05

FFL

DOOR DESCRIPTION

DO

OR

SC

HE

DU

LE

1

:50

FRAME PARTICULARS

IRONMONGERY

DOOR FINISH

FRAME FINISH

GLAZING

HINGES

D07D06

D09

LOCATION

MALE / FEMALE ENTRANCES, BABY CHANGING ROOM

TOILET CUBICLESPARAPLEGIC

SABS CATEGORY 2 STRONGROOM DOOR AND FRAME FINISHED WITH ZINC CHROMATE UNDERCOAT READY FOR FINAL COAT COMPLETE WITH CHROME FINISH FURNITURE TO SPECIALISTS. WALL OPENING SIZE TO BE 880x1940mm WITH OVERALL FRAME SIZE OF 1030x2010mm.

AS PER SUPPLIER

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

AS PER SUPPLIER

ARCHIVE

40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.-ACTUAL SIZE OF 300X300 ALUMINIUM DOOR GRILL TO MECHANICAL ENGINEER DETAILS

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.-ACTUAL SIZE OF 300X300 ALUMINIUM DOOR GRILL TO MECHANICAL ENGINEER DETAILS

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

1500

2400

2400

813 813 900

870

19702400

2400

2400

1500

1200

300

1000

1000

vertical grab rail

door handle

kick plate

PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.

PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.

PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.

PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.

813

2400

813

03 03

03

RH

LH

12

04

RH

LH

01

01

RH

LH

03

01

RH

LH

07

03

RH

LH

01

04

RH

LH

04

02

750

1500

2520

2250

STAFF/KITCHEN

TYPE

MATERIAL

FINISH

OPENING MECHANISM

FURNITURE

75mm X 1mm POWDER COATED STEEL SLATS, PERFORATED WITH 2mm HOLES

POWDER COATED STEEL SLATS

POWDER COATED - COLOR AS DULUX 30BB 53/012 OR SIMILAR APPROVED

MANUAL OPENING

STANDARD LOCK SYSTEM

01

D10

100kick plate

300

2400

2400

100mm under cut

D11

40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.

PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

STORE ROOM

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

1500

01

2400

D12

PLAY ROOM AND SICK ROOM

900

RH

LH

02

00

2400

40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.

APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

NONE

3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.

2400

2400

2400

3230

8675

MULTI-PURPOSE HALL 01

ACOUSTIC PANEL DOOR TO SUPPLIER SPECIFICATION

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/11/03 14:29:36

Designer

DOOR SCHEDULE

LDSD DESIGN PROTOTYPES

703 - REV A

Author

Checker

18/KMS/102

Page 16: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

1. FLOOR FINISHES 2. SKIRTINGS 3. WALL COVERINGS

1.1

PO

RC

ELA

IN T

ILE

S

1.2

PO

RC

ELA

IN T

ILE

S (

BO

RD

ER

)

1.3

PO

RC

ELA

IN T

ILE

S

1.4

PO

RC

ELA

IN T

ILE

S (

BO

RD

ER

)

1.5

ST

RE

TC

H C

AP

ET

(IN

FIL

L)

1.6

ST

RE

TC

H C

AP

ET

(B

OR

DE

R)

1.7

AC

CE

SS

FLO

OR

1.8

RE

SIL

IEN

T F

LO

OR

CO

VE

RIN

G

1.9

VIN

YL T

ILE

S

1.1

0 U

NT

INT

ED

ST

EE

L T

RO

WE

L G

RA

NO

LIT

H

2.1

PO

RC

ELA

IN T

ILE

S

2.2

140 x

19m

m M

ER

AN

TI

2.3

75x19m

m M

ER

AN

TI

2.4

PO

RC

ELA

IN T

ILE

S

2.5

ST

ON

E M

AT

T P

OR

CE

LA

IN T

ILE

S

2.6

GR

AN

O

3.1

PA

INT

3.2

PA

INT

3.3

PA

INT

3.4

PO

RC

ELA

IN T

ILE

S

3.5

TIM

BE

R C

LA

DD

ING

3.6

TIM

BE

R C

LA

DD

ING

3.7

ST

RE

TC

H C

AR

PE

T

3.5

DA

DO

RA

IL

SECURITY

RECEPTION

WAITING AREA

CIRCULATION 01

MULTI-PURPOSE HALL

STORE ROOM 01

FEMALE ABLUTION 01

MALE ABLUTION 02

PARAPLEGIC 01

BABY CHANGING ROOM

STORE ROOM 02

PLAY ROOM

STORE ROOM 03

STATIONARY

REGISTRY

ARCHIVE

ADMIN SUPPORT

SICK BAY

CONSULTINGOFFICE 01

CONSULTINGOFFICE 02

CONSULTINGOFFICE 03

OFFICE OPEN PLAN

MEETING AREA

WAITING AREA

STAFF/KITCHEN

BOARDROOM

HEAD OF FACILITY

PRINT ROOM

IT/SERVER

IN-TAKE

SCREENING

SUPERVISOR SOCIAL WORKER

CLEANER STORE

PARAPLEGIC 02

FEMALE ABLUTION 04

MALE ABLUTION 03

LIBRARY/COMPUTER LAB

COMMUNITY DEVELOPMENT PRACT.

COMMUNITY DEVELOPMENT SUPERVISOR

GROUP INTERVIEW

QUIET/OBSERVITION

MEETING AREA

CONSULTING OFFICE 05

CONSULTING OFFICE 06

OFFICE OPEN PLAN

CONSULTING OFFICE 07

CONSULTING OFFICE 08

CIRCULATION AREA 02

CIRCULATION AREA 03

GENERAL NOTES: FINISHES

1. FLOOR FINISHES

1.1 PORCELAIN TILE:600x600mm FULL BODY MATT NON-SLIP PORCELAIN TILES LAID TO TILE PATTERN, ON A SMOOTH, EVEN ANDDUST FREE SURFACEBED / SLAB WITH APPROVEDTILE ADJESIVENAME:CODE: SUPPLIER:

1.2 PORCELAIN TILE BORDER:300x300mm FULL BODY POLISHED PORCELAIN FLOOR TILES LAID ACC. TO TILE PATTERN, ON A SMOOTH, EVEN AND DUST FREE SURFACEBED / SLAB WITH APPROVED TILES ADHESIVENAME: CODE: SUPPLIER:

1.3 PORCELAIN TILES:600x600mm FULL BODY NON-SLIP STONE MATT PORCELAIN FLOOR TILES LAID ON A SMOOTH, EVEN AND DUST FREE SURFACE BED / SLAB WITH TILE JOINTS AT 5m c/c WITH APPROVED TILE ADHESIVE : NAME: CODE: SUPPLIER:

1.4 PORCELAIN TILE BORDER:300x300mm FULL BODY NON-SLIP STONE MATT PORCELAIN FLOOR TILES LAID ON A SMOOTH, EVEN AND DUST FREE SURFACE BED / SLAB WITH TILE JOINTS AT 5m c/c WITH APPROVED TILE ADHESIVE:NAME: CODE: SUPPLIER:

1.5 STRETCH CARPET (INFILL)STRETCH CARPET BORDER LAID ON A SMOOTH ON CLEAN AND DUST FREE SURFACERANGE: WESTMINISTERNAME: IRON STONEMANUFACTURER: NEXUS - BELGOTEX

1.6 STRETCH CARPET (BORDER)500mm WIDE STRETCH CARPET BORDER LAID ON A SMOOTH ON CLEAN AND DUST FREE SURFACERANGE: WESTMINISTERNAME: BLACK CITYMANUFACTURER: NEXUS - BELGOTEX

1.7 ACCESS FLOOR BY SPECIALIST

1.8 RESILIENT FLOOR COVERINGLINOLIUM HOMOGENEOUS FLOOR SHEETING 2,5mm THICK SINGLE LAYER ON JUTE BACKING ROLLS WITH WELDED JOINTS FIXED TO WELL FINISHED AND PROPERLY PREPARED SURFACE WITH SPECIAL ADHESIVE AS PER MANUFACTURER'S SPECIFICATION

1.9 VINYL TILES300x300x4mm THICK VINYL TILES LAID ACCORDING TOMANUFACTURER'S SPECIFICATION ON A SMOOTH, CLEANAND DUST-FREE SURFACERANGE: COLOUR: CODE: MANUFACTURER:

1.10 UNTINTED GRANOLITHUNTINTED GRANOLITH FINISH WITH SMOOTHTROWELLED FINISH

2. SKIRTINGS

2.1 PORCELAIN TILES:150x600mm PORCELAIN TILES LAID ACCORDING TO TILE PATTERN, JOINTS CONTINUOUS IN BOTH DIRECTIONS WITH ALUMINIUM EDGE STRIPSNAME: CODE:SUPPLIER:

2.2 MERANTI SKIRTING:140x19mm MOLDED MERANTI NAILED TO WALL AT 400mm C/C MAX. WITH 50mm STEEL NAILS. NAIL HEADS SUNK,HOLES FILLED AND FINISHED FLUSH, 19mm SA PINE1/4 ROUND NAILED TO SKIRTING WITH 25mm HEADLESSNAILS AT 300mm C/C MAX. NAIL HEADS SUNK, HOLESFILLED AND FINISHED FLUSH.

2.4 PORCELAIN TILES:600x600mm PORCELAIN TILES LAID ACCORDINGTO TILE PATTERN, JOINTS CONTINUOUS IN BOTH DIRECTIONS WITH ALUMINIUM EDGE STRIPNAME: CODE:SUPPLIER:

2.5 PORCELAIN TILES:150x600mm PORCELAIN TILES LAID ACCORDINGTO TILE PATTERN, JOINTS CONTINUOUS IN BOTH DIRECTIONS WITH ALUMINIUM EDGE STRIP NAME: CODE:SUPPLIER:

2.6 GRANO SKIRTING150mm HIGH MONOLITHIC UPWARD SLOPING CONCAVE GRANO SKIRTING

2.3 MERANTI SKIRTING:75x19mm MERANTI NAILED TO WALL AT 400mm C/CMAX. WITH 50mm STEEL NAILS. NAIL HEADS SUNK,HOLES FILLED AND FINISHED FLUSH, 19mm SA PINE1/4 ROUND NAILED TO SKIRTING WITH 25mm HEADLESSNAILS AT 300mm C/C MAX. NAIL HEADS SUNK, HOLESFILLED AND FINISHED FLUSH.

3. WALL COVERINGS

3.1 PAINT FINISH: MATT12mm SAND / CEMENT PLASTER WITH SMOOTH TROWELFINISH. TO RECEIVE PAINT FINISH 1 x HIGH HIDING POWER UNDERCOAT: SABS SPECIFICATION 681, GRADE 13 x EMULSION PAINT (INTERIOR): SABS SPECIFICATION 1586, GRADE 1COLOUR RANGE: CODE:

3.2 PAINT FINISH: MATT 12mm SAND / CEMENT PLASTER WITH SMOOTH TROWELFINISH. TO RECEIVE PAINT FINISH 1 x UTILITY GRADE UNDERCOAT: SABS SPECIFICATION 681, GRADE 23 x EMULSION PAINT (INTERIOR): SABS SPECIFICATION 1586, GRADE 1COLOUR RANGE: CODE:

3.3 PAINT FINISH: MATT12mm SAND / CEMENT PLASTER WITH TRUE TROWELFINISH. TO RECEIVE PAINT FINISH 1 x HIGH HIDING POWER UNDERCOAT: SABS SPECIFICATION 681, GRADE 13 x EMULSION PAINT (EXTERIOR): SABS SPECIFICATION 1586, GRADE 1COLOUR RANGE: CODE:

3.4 PORCELAIN TILE:300x600mm HALF BODY MATT NON-SLIP PORCELAIN TILES LAID TO TILE PATTERN, ON A SMOOTH, EVEN AND DUST FREE SURFACE WITH APPROVED TILE ADHESIVE WITH CORNER ALUMINIUM EDGE STRIPS AND HORIZONTALALUMINIUM STRIPS AT SPECIFIED INTERVALS NAME:CODE:VARYING SUPPLIER:

3.5 NON ACOUSTICAL TIMBER CLADDING TO DETAILS

3.6 ACOUSTICAL TIMBER CLADDING TO DETAILS

3.7 STRETCH CARPETSTRETCH CARPET BORDER LAID ON A SMOOTH ON CLEAN AND DUST FREE SURFACE FROM FFL. TO DADO RAILRANGE: NAME: MANUFACTURER:

3.8 DADO RAIL:PROFILED TIMBER RAIL ACCORDING TO PROFILE, FIXEDTO WALL AT 1m HIGH ON POSITIONS AS INDICATED ONDETAIL PLANS

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

1 : 50

2019/10/16 11:59:15

Designer

FINISHING SCHEDULE

LDSD DESIGN PROTOTYPES

800 - REV A

Author

Checker

18/KMS/102

Page 17: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

A

A

B

B

C

C

2 2

3 3

8 m²

Officep.tiles

2 m²

WCp.tiles

6025

205

230 2600 230 1430

6230 3060 1430

460

3190

1700

715

4360

1615

6230 2830 2160 2230

IN

OUT

D1

D1

A

200 - REV 02

A

200 - REV 02

AL2

AL1

W1

Boom gates to suppliers

specification

1 1

4 4

6690

AL1

D1

D

D

E

E

10720

230

900

230

3000

230

4590

230

95

5700

205

230 2600 230 1200 230

1700

2890

4590

Pedestrian Gate

hwbwc

worktop

Refer to fixed joinery drawings for details

Boom gates to suppliers

specification

B

200 - REV 02

B

200 - REV 02

1700

3190

460

1700

A

A

B

B

C

C

2 2

3 3

6230 2830 2160 2230

715

4360

1615

A

200 - REV 02

A

200 - REV 02

1 1

4 4

6690

D

D

E

E

B

200 - REV 02

B

200 - REV 02

Roof Pitch 7.5°

NEW Concealed fix 0.55mm thick and 700mm cover width profile, colour to be confirmed, C.1.S finish with standard backing coat g550 interlocking roof sheeting. AZ100 spelter to both sides fixed to steel purlins as per engineer's specifications using clips, screw fixed to steel purlins secured with No. 10x16mm or 12x22mm wafer head self-tapping screws, all in accordance with manufacturer's recommendations and INSTALLED BY ACCREDITED INSTALLER.

13450

GROUND FLOOR LEVEL0

WALLPLATE2805

Window Level2125

2 31 4

2125

2805

GROUND FLOOR LEVEL0

WALLPLATE2805

Window Level2125

A B C

680

2125

D E

2400

GROUND FLOOR LEVEL0

WALLPLATE2805

Window Level2125

ABC

2125

680

DE

2400

2400

2805

GROUND FLOOR LEVEL0

WALLPLATE2805

Window Level2125

23

2125

680

14

D1

Lotus Amoretti Michaelangelo Collection 40mm thick Horizontal 813 meranti door with horizontal slats, size 813 x 2032mm high. Sand down timber surface to a fine smooth finish and apply two coats Lotus Sheen quality timber sealant prior to installation, all in accordance with themanufacturer's recommendations.

3

Plascon Cashmere to exterior new wood (NW 525).Surface to be dry, sound and clean. Wash knots and resinous areas with Lacquer Thinners (ILS 1) and coat with Woodcare Knot Seal (PK 2) and apply one coat of Plascon Woodcare Pretreatment (WWP 1), overcoated within 48 hours with a moisture content, measured with a Doser Hygrometer (or equivalent), of BD 2 scale (A1-A5) < 14% or less. Prime with one coat of Wood Primer (UC 2) with an overcoating time of 16 hours and finish with two coats of Cashmere (CAS) with 2 hours drying time between coats, for a maintenance cycle of 7 years in a C1 - inland environment.

STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES

WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.

None

QUANTITY

DOOR LEAF

DOOR FINISH

FRAME TYPE

FRAME FINISH

GLAZING

DO

OR

SC

HE

DU

LE

1

:50

2115

813

W1 AL2 AL1

QUANTITY

WIN

DO

W

SC

HE

DU

LE

1:5

01 01 02

FRAME TYPE

GLAZING

ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS

DOUBLE CLEAR SAFETY "GSA SmartGlass ClearVue" glass, glazed in accordance with NBR N schedule 1 and SABS 0137.

FRAME FINISH

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVEDSYSTEM LIKE ALRODE COLOUR: BRONZE

ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS

DOUBLE CLEAR SAFETY "GSA SmartGlass ClearVue" glass, glazed in accordance with NBR N schedule 1 and SABS 0137.

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVEDSYSTEM LIKE ALRODE COLOUR: BRONZE

ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS

DOUBLE CLEAR SAFETY "GSA SmartGlass ClearVue" glass, glazed in accordance with NBR N schedule 1 and SABS 0137.

FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVEDSYSTEM LIKE ALRODE COLOUR: BRONZE

900

600

2780

1560

1200

1560

SCALE 1 : 100

GROUND FLOOR LEVEL

Client

service

cad file name

REVIT 2016

designed

drawing title

drawing number

ref. no

scale drawn

checkeddate

type number

NO DATE AMENDMENT

82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523

Email: [email protected]: www.kmsarch.co.za

POLOKWANE

Implementing Agent

ITE

MN

AM

EP

OS

ITIO

ND

AT

ES

IGN

AT

UR

E

1.

2.

3.

4.

DEPARTMENT APPROVAL

As indicated

2020/02/17 15:51:42

Designer

FLOOR PLAN, ROOF PLAN ANDELEVATIONS

LDSD DESIGN PROTOTYPES

100 - REV 02

Author

Checker

00000

notes in respect of sa standard code of practice for the application of the national building regulations, sans 10400

part d public safety· all balustrading to comply with dd2

part m stairways· dimensions of stairways to be in compliance with mm2· all balustrading to comply with mm3

part n glazing· all glazing to comply with sabs code n

part o lighting & ventilation· all areas to be artificially lit in compliance with oo6, offices & other habitable rooms min 35o lux, toilets min 160 lux· all designed by electrical consultant and in accordance with ohs act· natural ventilation of 5% of floor area· natural smoke ventilation of 1.5% of floor area· if required toilets to be mechanically ventilated by extraction to external at rate of 20l/s/fitment· all air conditioning will be designed by a professional engineer· and will be in accordance with nbs regulations

part p drainage· all joints to comply with pp2 & pp6· all sanitary fixtures to be in accordance with pp3 - pp5· all drainage to comply with the relevant portions of pp15, depending on type of system utilized

· all discharge & ventilating pipes to be installed in compliance with pp20· drains to be accessible in accordance with pp21· all sanitary fixtures to have traps in accordance with pp22· gully to comply with requirements of pp23· all drains to be laid in accordance with with pp24· all wet services are to be designed by a professional and registered engineer

part r stormwater disposal· sizes of roof valleys & gutters to comply with rr3· drains to be accessible in accordance with rr4· the stormwater disposal system shall be designed by a professional engineer

part s facilities for disabled persons· ramps to be provided in accordance with ss2· toilet facilities to be provided in accordance with ss5· parking bays to be provided in compliance with ss8· signage to comply with ss9part s facilities for disabled persons· ramps to be provided in accordance with ss2· toilet facilities to be provided in accordance with ss5· parking bays to be provided in compliance with ss8· signage to comply with ss9

part t fire protection· occupancy to comply with tt3· all materials to comply with tt5· all structural elements & components to comply with tt7· fire resistance of division seperating elements to comply with tt6· internal partitions and walls to comply with tt9· all openings to be protected in compliance with tt10· roof assemblies & coverings to comply with tt12· provision escape routes to comply with tt16· all exit doors to comply with tt17· all feeder & emergency routes to comply with tt18 & tt19· dimensions of components of escape routes to comply with tt20· width of escape routes to comply with tt21· reception area to comply with tt26· all access doors to emergency routes to be sabs class b 120 min rated doors fitted with self closers in compliance with tt10.4 & locks in compliance with tt19.9· all fire services are to be designed by a professional and registered fire consultant· all ceilings to comply with tt13· all floor coverings to comply with tt14· all wall finishes to comply with tt15· feeder routes to be provided in accordance with tt18· when partition layouts are designed - to be submitted under separate application· locks to escape & access doors to be fitted with knob/cylinder locks in compliance with tt19.9· ventilation to stairs to comply with tt24· all openings in floors to comply with tt26· signage to be provided in accordance with tt29, tt32, tt55,4 & tt55,5· emergency routes to be lit in accordance with tt30, designed by professional engineer & certificate issued on completion· water reticulation for fire fighting purposes to be comply with tt33· fire hose reels to be provided in accordance with tt34· hydrants to be provided in accordance with tt35· portable fire extinguishers to be provided in accordance with tt37 to the satisfaction of the chief fire officer

· any inaccessible concealed space with a max dimension of more than 5m to be fire stopped in accordance with tt39· service pipes, conduits & sleeves to comply with tt41· provision to be made for smoke ventilation and detection system designed in accordance with tt42, designed by professional engineer & certificate issued on completio· air conditioning system to be designed by professional engineer to comply with tt43 & certificate issued on completion· stairway to comply with tt23.6· parking to comply with tt51· no smoking signs to comply with tt44· sprinkler system to be designed by professional· engineer & certificate issued on completion

part u refuse disposal· refuse area to be constructed & provided with hose, bibtap & sump

water supply notes· existing municipal water conections to be used.· water pressure to be tested at existing fhr to determine if watertanks are required for fire hose reels.· all water supply pipes above ground with a diameter of 38mm or less are to be copper class 460/0. all pipes in chases to be spiral wrapped with kraftex building paper.· no pipes are to be installed below surface beds.· pipes in ground to be in upvc or hope installed to manufactures and sabs specification. all galvanised pipes used in ground shall be denso-protected in strict accordance with manufactures specification.

SCALE 1 : 100

ROOF PLAN

1 : 100EAST ELEVATION

1 : 100NORTH ELEVATION

1 : 100SOUTH ELEVATION 1 : 100

WEST ELEVATION

Page 18: ARCHITECTURAL DRAWINGS · 230mm thick Brickwall Type 6.2 including wall Type 6.5 with an ... Suspended Acoustic ceiling Type 9.4 refer to ceiling layouts 400 series ... 230mm thick

230

4 500

230

345 230 4 000 230

4 960

230

4 500

230

230

100

1 700

2 700

230

1 645

2 199

1 550

65

0

2 720

110

220

220

110

345 4 460

4 805

4 960

500 500 500 500 500 500

345 230 4 000 230

345 4 460

4 805

AA

concrete slab laid to a fall, details to eng's design

50mm concrete coping on bricks

4 brick course parapet wall

3

DIE

SE

L C

OU

PLE

D

PU

MP

A

SS

EM

BLY

ELE

CT

RIC

M

OT

OR

CO

UP

LE

D P

UM

P

AS

SE

MB

LY

PLAN

FRONT VIEW

3

DIESEL COUPLED PUMP

ASSEMBLY

ELECTRIC MOTOR

COUPLED PUMP

ASSEMBLY

ELECTRIC PUMP

CONTROLLER

DIESEL PUMP

CONTROLLER

JOCKEY PUMP

CONTROLLER

FUEL SUPPLY

LINE

PE

RF

OR

AT

ED

W

AL

L

DOOR GRILLE

DOOR GRILLE

50L Diesel

Fuel Tank

Ø110mm

Ø110mm

Ø 32mm

Ø65mm

Ø65mm

Ø110mm

Butterfly Valve

Check Valve

Ø110mm

Strainer

Butterfly Valve

Check Valve

Ø110mm Pipe

Connected to the

Lowest Point on

the Sectional Steel

Tank

ELECTRIC

DOMESTIC

WATER PUMP

Ø32mm Pipe

Connected to the

Upper Point on

the Sectional Steel

Tank

Ø32mm

Strainer

Butterfly Valve

Check Valve

Ø32mm

Ø32mm

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70) AecbDbPipeFitting (AecbPipeBase70)

AecbDbMvPart (AecbBldSrv70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbMvPart (AecbBldSrv70)

AecbDbMvPart (AecbBldSrv70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbMvPart (AecbBldSrv70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbMvPart (AecbBldSrv70)

AecbDbMvPart (AecbBldSrv70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipe (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

AecbDbPipeFitting (AecbPipeBase70)

FLOOR PLAN

scale 1:50

Top of Concrete (+0.000)

Lintel Level (+2.135)

NGL

Pump details ref to

Mech Eng's specs

SECTION A-A

scale 1:50

Top of Concrete (+0.000)

Lintel Level (+2.135)

NGL

FRONT ELEVATION

scale 1:50

RIGHT SIDE ELEVATION

scale 1:50

Top of Concrete (+0.000)

Lintel Level (+2.135)

NGL

Roan Satin facebrick

BACK ELEVATION

scale 1:50

Top of Concrete (+0.000)

Lintel Level (+2.135)

NGL

LEFT SIDE ELEVATION

scale 1:50

Wall Height (+3.120)

Vents Base (+1.000)

Wall Height (+3.120)

Top of Concrete (+0.000)

Lintel Level (+2.135)

NGL

Roan Satin facebrick

Wall Height (+3.120)

Wall Height (+3.120)

Roan Satin facebrick

Roan Satin facebrick

Maize Travertine Maize Travertine

Maize Travertine Maize Travertine

Maize Travertine Maize Travertine

Maize Travertine Maize Travertine

Roan Satin facebrick

Roan Satin facebrick

Roan Satin facebrick

Wall Height (+3.120)

Roan Satin facebrick

Maize Travertine Maize Travertine

Maize Travertine Maize Travertine

Vents Base (+1.000)

Vents Base (+1.000)

Roan Satin facebrick

Roan Satin facebrick

Maize TravertineMaize Travertine

Slab Level (+2.720)

Slab Level (+2.720)

Slab Level (+2.720)

Slab Level (+2.720)

Slab Level (+2.720)

Top of Concrete (+0.000)

Lintel Level (+2.135)

NGL

Wall Height (+3.120)

Slab Level (+2.720)

Vumesa (Pty) Ltd

SIGNATURE DATE

1B Deodant Building

10 Pyne Street,

PINETOWN,

3610

Tell : 031 701 1038

Fax : 03 701 0963

DESIGNED

DRAWN

CHECKED

APPROVED

SCALE

PUMP ROOM & GENERATOR PLINTH

DRAWING REVISIONS

REV DATE DRAWN CHECKED DESCRIPTION

NOTE: Only signed drawing are considered

as issued drawings.