Benefits The Ultimate 4D QA Solution A 4D isotropical cylindrical detector array for arc delivery QA and Dosimetry Arc CHECK ® 4D Patient plan QA - RapidArc, VMAT, Tomotherapy, and SmartArc - Conventional IMRT and 3D Conformal - 4D array worldwide market share leader DVH analysis (3DVH ® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot SunPoint ® Diode Detectors - Smallest detector (0.0000019cm) - Highest sensitivity - Proven stability Consistent BEV for all gantry angles Measure composite dose, and control point ranges Measures every pulse with real-time updates (50ms) Versatile cavity for detector inserts Single power/data cable. Manages all power and data in one connection Integrated electronics. ArcCHECK is self-contained with no electronics to setup separately; and unlike 2D arrays, a separate phantom is not needed Lightweight (16kg). ArcCHECK is easily portable for daily use without the need for a separate cart Easy setup. Leveling LED’s provide real-time feedback on device rotation and tilt for a precise and easy setup Patented user calibration. Clinically proven wide field calibration (WFC) takes only 30 minutes and does not require disassembly of the ArcCHECK device No pre-irradiation. No Pre-irradiation or warm-up required for absolute dose measurements Ease of Use Your Most Valuable QA and Dosimetry Tools Rn RADON FFF Beams VMAT RapidArc ® TomoTherapy ® Pinnacle 3 SmartArc™ Conventional IMRT Compatible with: U.S.Patent No. 8,044,359; 6,125,335 T +31 (0)24 648 86 88 Nederland België / Belgique T +32 (0)3 309 32 09 www.gotoPEO.com [email protected]

ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

Benefits

The Ultimate 4D QA SolutionA 4D isotropical cylindrical detector array for arc delivery QA and Dosimetry

ArcCHECK®

4D Patient plan QA

- RapidArc, VMAT, Tomotherapy, and SmartArc

- Conventional IMRT and 3D Conformal

- 4D array worldwide market share leader

DVH analysis (3DVH® Option)

Machine QA

- Tests for MLC, flatness, symmetry, starshot

SunPoint® Diode Detectors

- Smallest detector (0.0000019cm)

- Highest sensitivity

- Proven stability

Consistent BEV for all gantry angles

Measure composite dose, and control point ranges

Measures every pulse with real-time updates (50ms)

Versatile cavity for detector inserts

Single power/data cable. Manages all power and

data in one connection

Integrated electronics. ArcCHECK is self-contained

with no electronics to setup separately; and unlike

2D arrays, a separate phantom is not needed

Lightweight (16kg). ArcCHECK is easily portable

for daily use without the need for a separate cart

Easy setup. Leveling LED’s provide real-time feedback on

device rotation and tilt for a precise and easy setup

Patented user calibration. Clinically proven wide field

calibration (WFC) takes only 30 minutes and does not

require disassembly of the ArcCHECK device

No pre-irradiation. No Pre-irradiation or warm-up

required for absolute dose measurements

Ease of Use

Your Most Valuable QA and Dosimetry Tools

RnRADON

FFF BeamsVMATRapidArc®

TomoTherapy®

Pinnacle3 SmartArc™Conventional IMRT

Compatible with:

U.S.Patent No. 8,044,359; 6,125,335

T +31 (0)24 648 86 88

Nederland België / Belgique

T +32 (0)3 309 32 09 [email protected]

Page 2: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

2

With ArcCHECK, see the entire picture

Below is what a 2D array and ArcCHECK will see for the same plan measurement. ArcCHECK highlights areas that would

not normally be seen with a 2D array. Measure and correlate gantry angle, leaf end position, absolute dose and time

(4D) to identify the source of the error. Error sources include a TPS, delivery system, imaging system, setup, and MLC.

2D Array Measured: With a 2D array, only a fraction of dose

information is available, this is inherent with all available 2D arrays

What you see with a 2D array What you see with ArcCHECK

0o 180o

ArcCHECK Measured: ArcCHECK displays BEV dose distribution

throughout the entire arc delivery. More data is available to perform

a more thorough QA analysis

2D

1D

3D

3D

3DVariable Coherent. ArcCHECK detectors and their angle of

incidence remain coherent to the delivery beam

regardless of angle. The BEV detector geometry does

not change based on angle. When a 2D array is irradiated

obliquely, the 2D array degrades to 1D. Even if there is no

detector shadowing effect, significant information is lost

on a 2D array.

Shape. Phantoms are ideally shaped like a patient. The

cylindrical design of ArcCHECK intentionally emulates patient

geometry to better match reality.

Lost data

Lost data

Chambers Ion chamber measurements lack high-resolution, resulting in a blurred measurement

Diodes Diodes are capable of accurate, reproducible high-resolution measurements. ArcCHECK usesSunPoint Diode Detectors

EPID/Film EPIDs and film have good density and resolution, however absolute dose, accuracy, uniformity and reproducibility need to be verified

SunPoint® Diode Detectors: The Right Choice for QA & Dosimetry

A cylindrical design is most appropriate for arc delivery applications

Page 3: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

3ArcCHECK

Hardware

ArcCHECK Detector BEV (Beams Eye View)Beam Delivery

Leading Specifications

1386 SunPoint Diode Detectors

21.0cm array diameter and length

Patented user calibration

Only one cable connection

Lightweight -16.0kg

HeliGrid™

Helical detector geometry

Less detector overlap from a BEV perspective

Increased detector density

Cylindrical Advantage: Coherent QA

BEV is consistent regardless of angle

- Detectors remain coherent to beam vectors

Measure entrance and exit dose

Versatile central cavity

Cylindrical array is shaped like a patient

Central Cavity

Reduces weight

Tests TPS modeling

Accommodates inserts and detectors

21 x 211386 Detectors

10 x 10230 Detectors

ArcCHECK contains a sophisticated yet easy to use leveling

system that ensures setting up for measurement is quick

and easy. With built in rotation and tilt inclinometers, the

ArcCHECK can relay setup status to the user in real-time.

Leveling LED’s

Power/Data Cable

Hardware that is easy to setup and use

Page 4: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

4

Stringent measurement

ArcCHECK shown with the optional CavityPlug for measuring dose at isocenter.

Acrylic insert

Detector holder

MultiPlugTM

CavityPlugTM

ArcCHECK measures entry and exit dose for every angle.

Measuring completely around the isocenter in a uniform

manner for each angle is a more stringent measurement

than a simple composite dose at the isocenter. Errors visible

in the isocenter can also be visible in the surrounding dose

measurements, but in more detail.1 For those who would

like to measure the dose at isocenter or elsewhere within

the cavity, Sun Nuclear offers the versatile MultiPlug, and

CavityPlug with detector insert.

it PlTM

Entrance dose

Exit dose

Features MultiPlug CavityPlug

Hounsfield conversion testing

Precision fitted to ArcCHECK cavity

Inhomogeneity insert options

Muscle -Bone -Lung -

Adipose -Titanium -

Dose in cavity center

Dose in up to 25 unique locations

Film cassette insert

Bezel angle indicator for rotation within cavity

PMMA (acrylic) construction

Included precision milled detector holder

Included solid insert for completely solid cavityFeat

ure

Co

mp

aris

on

ArcCHECK shown with the optional MultiPlug for measuring dose at up to 25 locations.

Page 5: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

5ArcCHECK

Virtual Inclinometer™

For any delivery, ArcCHECK will calculate

the gantry angle independently using a

unique Virtual Inclinometer. This enables

correlation of dose and time with angle (4D).

The Virtual Inclinometer is accurate to ±1°,

and avoids additional inclinometer cables

and mounting to the delivery system.

Control Point Analysis

Scrutinize arc plans via ArcCHECK’s Control

Point Analysis feature. Individual control

points and user defined arc sections can

be analyzed for a full arc or sub-arc.

A unique polar graph with movie playback

offers a 360° presentation of pass, low, and

high dose summary for the defined control

point range and sub-arcs.

Charted gantry angle as a function of time

Automatic gantry angle calculation display

Measured Planned

Control Point Analysis

Machine QA

Use ArcCHECK for a wide variety of machine

QA tests. Easily check reproducibility and

export data files for independent analysis.

In version 6.2, use built in tests for:

Gantry angle QA with ArcCHECK

Gantry Angle QA MLC QA

Starshot Flatness*

- Gantry rotation Symmetry*

- Collimator rotation

- Couch rotation

*Photons only

Page 6: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

6

The ArcCHECK interface is SNC Patient software; a powerful

and proven patient QA and analysis tool with over 2000

clinical installations.

The same analysis and workflow options from MapCHECK

are available in ArcCHECK

For larger fields, two ArcCHECK measurements may be

concatenated

All data files from ArcCHECK are an open format for easy

export, including raw data

ArcCHECK QA plans are in three dimensions. DICOM

RT Dose is imported and a 3D dose grid corresponding

to detector locations is extracted for comparison to

measured.

SNC Patient™ Software

With a single mouse click, SNC Patient Software compares measured dose points to planned dose points. Users can compare normalized data or absolute dose data using distance to agreement or Gamma. Three adjustable criteria guarantee maximum flexibility and are easily adjusted. Measured points that do not fit within the acceptance criteria are highlighted red for high dose and blue for low dose.

1

234

6

5

1 Compare: Measure, then click compare to see the results against the planned file

2 TH: Isodose percentage line that defines the dose area to evaluate

3 % Diff: Percent acceptance criterion between Set 1 and Set 2 dose values

4 mm: Distance-to-agreement criterion

5 % Pass: Percentage of detector points that passed within the defined threshold with a pass/fail indication

6 Calc Shift: Determines a misalignment between measured & planned dose maps and automatically corrects if accepted by the user

measured

compare

profiles, histograms, more...

Angle of measurment indication

Page 7: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

7ArcCHECK

DVH Analysis (3DVH)

3DVH is a patented (U.S.Patent No. 7,945,022) method that enables the

comparison of measured and planned DVH’s without the complications

of a secondary dose algorithm. The planned DVH is extracted from the

DICOM patient plan file, then compared to the ArcCHECK measured

DVH result.

planned

1 Measured ArcCHECK dose differences perturb

the original planned dose, allowing comparison of

original planned and as measured planned

2 DICOM RT structures are presented for DVH

analysis, giving a clinically significant analysis of

the impact of measured dose differences

3DVH Independent Publications1) “Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors”

Med Phys. 2011 Oct;38(2):1037-10442) “ Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA”

Med Phys. 2011 Oct;38(10):5477-893) “Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA”

Med Phys. 2012 Jan;39(1):81-64) “VMAT QA: Measurement-guided 4D dose reconstruction

on a patient” Med. Phys. 2012 July; 39(7), 4228-4238

Page 8: ArcCHECK - peo-radiation-technology.com€¦ · - 4D array worldwide market share leader DVH analysis (3DVH® Option) Machine QA - Tests for MLC, flatness, symmetry, starshot ®SunPoint

1386 SunPoint Diode Detectors

Helical Grid (HeliGrid) Geometry

21.0cm Array Length

1.0cm Detector Spacing

Central cavity

Features

21.0cm Array Diameter

All data used is best available at time of publication. Data is subject to change without notice. All Content ©2012, Sun Nuclear Corporation. All Rights Reserved. Elekta, VMAT and its logo are all trademarks of Elekta AB. TomoTherapy and its logo are all registered trademarks or service marks of TomoTherapy Inc. RapidArc and its logo are all trademarks of Varian Medical Systems, Inc.

sun

2.9cm Physical Detector Depth

SunPoint®

PRECISION QA

Detector type: SunPoint Diode Detectors

Detector quantity: 1386

Detector spacing (cm): 1.0

Array diameter (cm): 21.0

Array length (cm): 21.0

Cavity diameter (cm): 15.0

Inherent buildup (g/cm2): 3.2

Inherent backscatter (g/cm2): 3.2

Detector physical depth (cm): 2.9

Array geometry:Helical Grid (HeliGrid) 1cm offset

Phantom Material: PMMA (Acrylic)

Active detector area (mm2): 0.64

1222D06182012

1 “Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy”, Daniel Létourneau, Julia Publicover, Jakub Kozelka, Douglas J. Moseley and David A. Jaffray, Medical Physics, Vol. 36, No. 5, May 2009

2 “Modeling the instantaneous dose rate dependence of radiation diode detectors”, J. Shi, W.E. Simon, T.C. Zhu, Med. Phys. 30 (9), 2509-2519 (2003).

3 “Performance evaluation of a diode array for enhanced dynamic wedge dosimetry”, T. C. Zhu et al, Med Phys 24, 1173-1180 (1997).

4 “Dose rate and SSD dependence of commercially available diode detectors”, AJ S. Saini and T. C. Zhu, Med. Phys., 31 (4), 914-924 (2004).

Testimonial - “We are using the ArcCHECK for about a year now for QA of our clinical IMRT plans. On the basis of our experiences we can conclude that the ArcCHECK is not only suitable for the QA of Elekta Linacs, but also for small stereotactic fields (up to 3x3 mm2) from a Novalis Linac (Brainlab).”

- Dr. Paul Rietveld, Ph.D. Radiotherapiecentrum The Netherlands

Detector volume (cm3): 0.000019

Detector stability: 0.5%/kGy at 6MV

Dose rate dependence: ± 1%, 75 - 250cm SSD

Update frequency (ms): 50

Radiation measured: Photons, Co-60 to 25 MV

Number of connection cables: Single power/data cable

Dimensions (cm2) / Weight (kg): 27.0 x 43.0 / 16.0

Operating system: Windows 2000, XP, Vista, 7 (32 or 64 bit)

Computer Requirements:

4GB RAM, 1 available USB 2.0 port, Dual-core processor (2.4GHz or higher), 5GB hard disk space, 32MB VRAM video card, 32-bit color depth, OpenGL hardware accelerated

Specifications