12
Aquanova Aries 1800 Product Care & User Operating Instructions Abacus Healthcare Services Ltd, Unit 1 Millennium Way, High Carr Business Park, Newcastle-under-Lyme, ST5 7XE Tel: 01782 569330 Fax: 01782 569349 Sales: 0800 454810 www.abacushealthcare.co.uk e-mail: [email protected]

Aquanova Aries 1800 User Guide

Embed Size (px)

DESCRIPTION

Abacus Healthcare

Citation preview

Page 1: Aquanova Aries 1800 User Guide

Aquanova Aries 1800Product Care & User Operating Instructions

Abacus Healthcare Services Ltd, Unit 1 Millennium Way, High Carr Business Park, Newcastle-under-Lyme, ST5 7XETel: 01782 569330 Fax: 01782 569349 Sales: 0800 454810 www.abacushealthcare.co.uk e-mail: [email protected]

Page 2: Aquanova Aries 1800 User Guide

Minimum rim height 580mmLift range (combined) 400mmFill volume 268 LitresTime to fill 4.0 min at 2 bar pressureTotal weight (including 80kg patient) 230kgElectric/hydraulic motor 300 WattElectrical 24 Volt DC battery/transformerMinimum dimensions (w_h_l) 800_630_1800mmMaximum dimensions (w_h_l) 800_1000_1800mmInternal dimensions (rim) (w_d_l) 550_440_1600mmInternal dimensions (base) (w_d_l) 520_440_1300mmSafe working load (bath) 150kg

Technical Product Specification

Dimensions

1800mm 800mm

600mm440mm

1800mm800mm

1000mm

630mm 1600mm

2

Fig. 1

Page 3: Aquanova Aries 1800 User Guide

AAbbaaccuuss HHeeaalltthhccaarree SSeerrvviiccee LLiimmiitteedd

COMMISSIONING CERTIFICATE

This is to confirm that the

Aquanova Leo Bath

Serial No: __________

at

______________________________________________________________________________

____________

has been commissioned on the __/__/____

the Guarantee expires on the __/__/____

Signed by: _____________________

Date: ________________________

Abacus Healthcare Services Ltd, Unit 1, Millennium Way, High Carr Business ParkNewcastle under Lyme, Staffordshire, ST5 7XE

Tel: 0870 770 8693 Fax: 0870 770 8698

email: [email protected]

3

Max.Pownall
Text Box
Tel: 01782 569330 Fax: 01782 569349 email: [email protected]
Max.Pownall
Text Box
Aquanova Aries 1800 Bath
Page 4: Aquanova Aries 1800 User Guide

Warranty

Our bath products are guaranteed for a period of twelve months from the date of commissioning.

All parts are covered against defects that may arise as the result of faulty materials, inferior workmanshipor construction.

The baths are not covered for any problems that may arise from the installation or site planning unlesscarried out by engineers from Abacus Healthcare Services Ltd.

Any consequence arising from unskilled or incorrect handling of the product is not covered by thisguarantee.

The following items, when supplied by Abacus Healthcare Services Ltd are guaranteed for a periodof twelve months from the date of supply for the parts only (labour costs are not covered).

• Taps and mixers

• Shower hoses, shower heads and shower brackets.

• Flexible pipes including waste outlet, hot and cold supply.

Hot and cold taps and mixer taps are proprietary fittings and as such carry a standard manufacturer’swarranty.

Note: Thermostatic mixing valves must be adjusted for the appropriate discharge temperature bythe installer. These require regular maintenance for which Abacus engineers are available.

• Electrical

All electrical components fitted to Aquanova baths are CE marked to comply with current EuropeanStandards.

Electrical items must not be replaced with alternative components without the authorisation of AbacusHealthcare Services Ltd.

Failure to obtain such authorisation will exempt the Company from any liability to action for further failure.

4

Page 5: Aquanova Aries 1800 User Guide

Safety Instructions

Always ensure the equipment is operated by trained staff.

Regularly clean the bath using non-abrasive cleaners.

Always ensure the mains electricity is switched on.

Always have the equipment serviced regularly (see Service Level Agreement).

Always keep users hands away from moving parts.

Always ensure the shower head is returned to it’s holder when not in use.

Never use the bath for any purpose other than that it has been designed.

Never leave the bath with the platform in a raised position.

Never allow other equipment such as hoists to contact the bath forcibly as this may cause damage.

Never allow items such as the shower head to remain beneath platform when raising the bath.

Whirlpool use and safety

Ensure you have a minimum of 50mm of water above the highest jet before switching on your whirlpool.

Check, especially after the children have used the bath, that they have not pushed small toys or otherobjects into the jets or suction fitting.

Check regularly that all debris is cleared from around the suction fitting.

Switch off your whirlpool at the RCCB after use.

Ensure that adequate access is left for maintenance and servicing.

Do not switch on your whirlpool without any water in the bath since this will damage the whirlpool pump.

Do not use large amounts of standard bubble bath in the water since this will fill the room with soapbubbles.

Do not run unmixed hot water directly on to the suction fitting.

Do not let anything cover the suction fitting during use, especially you.

Do not try to put your finger in a jet whilst the whirlpool is working.

Do not leave children unattended in the bath with the whirlpool system switched on.

Do not wash your hair in a bath fitted with a whirlpool system when the system is working.

Do not wash animals in a bath fitted with a whirlpool system.

Do not modify your whirlpool in any way. This would result in the guarantee becoming invalid and couldresult in the system becoming dangerous.

Maintenance

After each use: Dissolve a sterilising tablet into the bath water prior to sending the water to waste.Clean the bath and fittings using a soft cloth and non abrasive cleaner with anti-bacterial agent.

Monthly: Whirlpool sanitisation using Abacus Healthcare approved cleaner.

Annually: Servicing by an approved company in accordance with the manufacturer’s instructions.

5

Page 6: Aquanova Aries 1800 User Guide

Operating Instructions

1. To close the pop up waste rotate the chrome turn handle clockwise until the wasteplug locates in the outlet (fig. 2).

2. With the bath in the lowered position fill thebath with water to your required level.

3. Check the temperature of the water.

4. Set the bath level at the height appropriate fortransfer of the bather (as low as possible for anambulant transfer or raised to allow access for aportable hoist) (fig. 3).

A: Ambulant

B: Ceiling Track Hoist

C: Mobile/Portable Hoist

6

Fig. 2

Fig. 3

A

B

C

Fig. 4

Page 7: Aquanova Aries 1800 User Guide

Operating Instructions (continued)

7

Fig. 6

Fig. 5

5. Allow/assist the bather to transfer into thebath.

6. Raise the bath, full of water, by pressing and

holding the icon on the membrane padon the bath rim (fig. 5).

7. When bathing is completed lower the bath to

the position as in 4, for easy transfer (ambulant

or hoist) by pressing and holding the icon

on the membrane pad on the bath rim (fig. 6).

8. Allow/assist the bather to transfer out of thebath (see transfers - fig. 4).

9. Assist to towel dry/dress the bather.

10. Empty the bath using the pop up waste turning handle.

10. Make the bath ready for the next bather (clean, disinfect etc).

Page 8: Aquanova Aries 1800 User Guide

8

Service Level Agreement

As the manufacturer of your bath we are able to offer a unique range of services, which, due to themodular construction of the bath will extend the working life of the bath and provide a cost effectivesolution to protect your investment by offering the prospect of upgrading your bath to the latestspecification.

Abacus Service Plans

There are three foundation plans, which can be added to or modified to personalise service cover to meetthe needs of the individual customer. They are based on an evergreen contract, which will be renewedautomatically so that cover is always in place.

Minimum Cover

Recommended: Where the usage is relatively low and bathing facilities whilst important are not critical ona daily basis.

Comprises:

• Includes one full service visit each year

• Cover available Mon – Fri, 09:00 to 17:00

• All labour costs for the pre-planned service

• All consumable costs for service

• All travel to and from site

• 10% discount on list price of Engineer Call out, Labour & Parts

• Supplying Certificate of Maintenance

• Supply of LOLER Certificate where type requires this test

• Priority response

Does not include:

• Emergency call out response time

• Non consumable parts

• Time limited repair

• Agreed contract KPI’s

• Out of hours contact numbers

Page 9: Aquanova Aries 1800 User Guide

Standard Cover

Recommended: Where the bath has regular usage of up to 4 times daily. Although it may not be the onlybathing facility its loss could compromise client or patient care.

• Includes two full service visits each year

• All labour costs for the pre-planned services

• All consumable costs for both services

• Unlimited breakdown cover for labour

• Unlimited breakdown cover for parts (includes 1 off like for like tap replacement)

• Engineer call out

• All travel to and from site

• Supplying Certificate of Maintenance

• Supply of LOLER Certificate where type requires this test

• Priority response given to contract customers over non- contract customers

• Guaranteed call out response within 5 working days

• Guaranteed fix within 10 days

• Option of 4 year contract with a new bath includes 1 new shell

• Option of 4 year contract with a new bath includes 2 replacement like for like tap units

• Option of 4 year contract with a new bath includes up to 4 off replacement panels even for damage caused by misuse and/or accident

Comprehensive Cover

Recommended: Where the bath has regular usage of over 4 times daily. It may be the only bathing facilityand its loss could compromise significantly client or patient care. In this situation where the bath must beavailable at all times comprehensive cover brings peace of mind as well as extending the life of the bath.

Service as for Standard Cover plus:

• On request refresher training for staff twice per annum

• Service call out available Mon – Fri, 08:00 to 18:00

• Guaranteed emergency call out response within 16 working hours

• Guaranteed supply and repair fix within 5 working days

• Failure to meet agreed call out KPI refunds the equivalent of one weeks service plan

• Failure to meet agreed repair fix KPI refunds 5% of contract price up to 50% of total service plan price.

• Option of emergency call out service available 0800 to 22009

Page 10: Aquanova Aries 1800 User Guide

Locking Devices

Bath Locking Device

1. All Aquanova baths with a Membrane Keypadhave a lock sequence to prevent unauthoriseduse.

2. To lock the bath, press the two locking keyssimultaneously (fig. 7).

3. Check the lock sequence is set by trying tooperate the bath.

4. To unlock the bath, press the two locking keysagain simultaneously.

5. Check that the bath is operating by pressingthe icon.

10

Locking Keys

Fig. 7

Page 11: Aquanova Aries 1800 User Guide

11

Fault FindingS

ympt

om

The

bath

will

noto

pera

te

The

cont

rolb

utto

nsdo

notw

ork

The

seat

isst

uck

atth

eto

p

The

reis

aw

ater

leak

The

reis

ahy

drau

licoi

llea

k

Wat

erte

mpe

ratu

reva

riabl

e

*Tel

eph

on

e08

7077

086

93-

Ser

vice

Dep

artm

ent

The

bath

shel

lwill

notg

odo

wn

The

supp

lyto

the

batte

rych

arge

rha

sbe

enin

terr

upte

dC

heck

that

the

batte

rych

arge

rha

sno

tbee

nsw

itche

dof

f

Che

ckth

atth

eba

ttery

char

ger

has

notb

een

switc

hed

off

Che

ckth

atth

eba

ttery

char

ger

has

notb

een

switc

hed

off

Fol

low

proc

edur

efo

rch

ecki

ngth

eke

ypad

oper

atio

nab

ove

Fol

low

proc

edur

efo

rch

ecki

ngth

eke

ypad

oper

atio

nab

ove

Fol

low

proc

edur

efo

rch

ecki

ngth

eke

ypad

oper

atio

nab

ove

Fol

low

proc

edur

efo

rch

ecki

ngth

eke

ypad

oper

atio

nab

ove

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Che

ckw

ater

tem

pera

ture

byus

ing

ath

erm

omet

er

Che

ckth

esu

pply

flow

and

wat

erte

mpe

ratu

reus

ing

ath

erm

omet

er

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Insp

ectt

heba

thsh

ellf

orda

mag

e-

ifth

eba

thha

sa

show

eran

dpl

atfo

rmlo

okfo

rsi

gns

oftr

appi

ng

Che

ckth

eor

igin

ofth

ew

ater

and

posi

tion

rela

tive

toth

eba

th

Che

ckth

esh

ower

dive

rtor

onth

eta

pan

dth

eco

nnec

tions

ofth

esh

ower

hose

/sho

wer

head

Con

tact

Aba

cus

Hea

lthca

reS

ervi

ces

Ltd*

Che

ckth

atth

eba

ttery

char

ger

has

notb

een

switc

hed

off

Che

ckth

atth

eke

ypad

has

notb

een

lock

edby

pres

sing

the

two

lock

ing

keys

sim

ulta

neou

sly

toun

lock

the

bath

-se

e

Pag

e5,

Fig

4.Tr

yto

rais

eth

eba

thag

ain

bypr

essi

ngth

eba

thra

isin

gic

on-

see

Pag

e7,

Poi

nt6

Fig

9.If

this

fails

repe

atth

ispr

oced

ure

once

mor

e.

The

batte

rych

arge

rha

sfa

iled

The

batte

ries

have

lost

thei

rch

arge

orha

vefa

iled

The

cont

rolb

oxha

sfa

iled

Par

toft

helif

ting

mec

hani

smha

sfa

iled

The

reis

abr

oken

elec

tric

alco

nnec

tion

inth

esy

stem

The

reis

abr

oken

mec

hani

calc

ompo

nent

inth

esy

stem

The

keyp

ad/a

irsw

itch/

pend

antc

ontr

olha

sfa

iled

The

keyp

ad/a

irsw

itch/

pend

antc

ontr

olha

sfa

iled

The

ram

/pum

pset

has

faile

d(s

eals

/loss

ofhy

drau

licflu

id)

The

pum

pm

otor

has

faile

d(b

urne

dou

t/con

tam

inat

ed

with

oil)

The

wat

ersu

pply

toth

eba

thha

sfa

iled

(dam

aged

brok

enpi

peor

conn

ectio

n)

Att

hesh

ower

this

may

beth

edi

vert

oror

conn

ectio

ns

hose

/han

dset

The

reis

ada

mag

ed/b

roke

npi

peor

conn

ectio

nin

the

hydr

aulic

syst

em

The

tem

pera

ture

cont

rolh

asfa

iled

(req

uire

dad

just

ing

/cle

anin

g/re

plac

ing)

The

keyp

ad/a

irsw

itch/

pend

antc

ontr

olha

sfa

iled

The

bath

shel

lmay

have

beco

me

deta

ched

from

the

uppe

rfr

ame

The

bath

isfit

ted

with

sing

leac

ting

scis

sor

liftr

ams

The

oils

eals

onth

ese

atra

mha

vebe

com

eda

mag

ed

The

reis

dam

age

onth

esc

isso

rlif

tram

s

The

hot/c

old

supp

lyha

sbe

enin

terr

upte

d

The

bath

shel

lis

dam

aged

The

liftin

gm

echa

nism

may

have

over

ridde

nth

elim

it

switc

hes

Pos

sibl

eC

ause

Fau

ltF

indi

ngP

roce

dure

Page 12: Aquanova Aries 1800 User Guide

Aries 1700 Aries 1800 Pisces

Gemini Leo Leo Plus

Scorpio Scorpio Plus Scorpio Fixed Height

Diana Ceiling Hoist Portable Hoist

Wash Hand BasinBalena Changing Bench

Abacus Healthcare Services Ltd, Unit 1 Millennium Way, High Carr Business Park, Newcastle-under-Lyme, ST5 7XETel: 01782 569330 Fax: 01782 569349 Sales: 0800 454810 www.abacushealthcare.co.uk e-mail: [email protected]

SBAQ02 ­ Issue 04 - 28.03.11