13
© Westell Technologies Part # 030-300800 Rev A WESTELL.COM RELEASE NOTES Application Package Version 3.2.1 Release Notes Rev A March 2017

Application Package Version 3.2.1 Release Notes Rev A ...support.westell.com/documents/Release-Notes/Apps_pkg_3.2.1_RN.pdf · Management System ® are registered ... All ODU Optic

  • Upload
    trannhi

  • View
    218

  • Download
    6

Embed Size (px)

Citation preview

Application Package

Version 3.2.1

Release Notes Rev A March 2017

© Westell Technologies

Part # 030-300800 Rev A

WESTELL.COM

RELEASE N

OTES

Application Package Version 3.2.1 Release Notes

Copyright © 2017 by Westell Inc. All Rights Reserved. Westell, Kentrox® and Optima Management System® are registered trademarks of Westell. All other names are trademarks of their respective owners. Information is correct at time of publication and is subject to change without notice. Contact Westell in Aurora, Illinois to verify current product information. Westell, Inc. is an Equal Opportunity/Affirmative Action employer.

Westell, Inc.750 North Commons Drive

Aurora, IL 60504 USAToll Free: (800) 377-8766

International: +1 (630) 375-4950 Fax: +1 (630) 375-4931

TABLE OF CONTENTSAffected Types Page 2

New Supported Devices Pages 3-5

76779 -- Volt Server Gen 2 Page 3

77108 -- BARD HVAC Controller Phase I Integration Page 3

77110 -- QUEST RSC1000 HVAC Controller Phase I Integration Page 4

76187 -- Support for Delta Rectifier with Orion Controller Page 4

77114 -- Support for GE Infinity M/S Rectifier Page 4

77115 -- DeviceAgent Monitoring Support for Westell Model DSP85 Repeater

Page 5

77155 -- Support for Elkor WattsOn Mark II Page 5

New Features Page 5

77100 -- Changes to Alarms Affecting Uptime Pages 5-6

77123 -- Device Agent Static NE Attributes Page 6

77139 -- Tower Light Versions Set As NE Attributes Pages 6-7

77213 -- Add measurements to the Basler Generator Management Page 7

New Firmware Support Page 8

77101 -- Support for Commscope ION-U firmware 1.80 Page 8

Fixes Page 8

76511 -- Attribute Updates on MobileAccess SC-450 Page 8

77276 -- Non-printable characters in JMA subrack name cause sync failure in Optima

Page 8

Known Issues Page 8

77277 -- SPX Vanguard SNMP Tower Light does not support discrete alarming Page 8

Device Compatibility Information Pages 9-12

WESTELL.COM

Page 1

1-800-377-8766

Application Package Version 3.2.1 Release NotesAffected Types

Application PackageRelease Notes

Version 3.2.1March 2017

Note: Preceding versions of this Westell product bundle were titled “Kentrox Modules.” Effective with the issuance of Version 3.0.1, these bundles are renamed “Application Package.”

Affected Types

Vendor Models Configured Types Issue(s)

BARD MV5000 HVAC Controller BardMV5000HVACSystem 77108

Basler DG2020 Generator BaslerDG2020Generator 77213

Commscope Ion RMC1600 ION-U AndrewIONDAS 77101

Corning Mobile Access SC-450 MobileAccessSC450DAS 76511

Delta Rectifier with Orion controller

DeltaOrionRectifier 76187

Dialight All tower light types 77139

Elkor WattsOn Mark II AC Power Meter

ElkorMarkIISplitPhasePowerMeter 77155

GE Infinity Rectifier GEInfinityRectifier 77114

JMA Teko DAS JMATekoDAS 77100, 77276

Quest RSC1000 HVAC Controller QuestRSC1000HVACSystem 77110

SPX VanguardSNMP tower light

SPXVanguardSNMP 77277

SPX All Flash Tower Light types 77139

VoltServer MGT500 VoltServerMGT500 76779

Westell DSP85 Repeater N/A 77115

WESTELL.COM

1-800-377-8766

Page 2

Application Package Version 3.2.1 Release NotesNew Supported Devices

New Supported Devices

76779 -- Volt Server Gen 2

Version 3.2.1 includes support for the VoltServer MGT500, the second generation of the VoltServer Digital Electricity remote powering solution. This includes basic monitoring including alarms and key measurements.

The following is a sample configuration:

config site module Tower

application DASMonitoring enable

config site network-element-set DigitalPower

instance mgtA

display-name MGT500 A

exit

config site network-element mgtA

type VoltServerMGT500

param deviceIp 192.168.1.100

77108 -- BARD HVAC Controller Phase I Integration

Version 3.2.1 includes the first phase of integration of the BARD HVAC controller. This supports basic monitoring including alarms, key measurements, and status information. Full support and control will follow in Phase II in an upcoming version.

The following is a sample configuration:

config site module Tower

application HVACMonitoring enable

application EnvironmentalMonitoring enable

config site network-element hvacSystem

type BardMV5000HVACSystem

param deviceIp 192.168.1.100

Note: Both the MV5000 and MC4000 models are supported using the same type.

WESTELL.COM

Page 3

1-800-377-8766

Application Package Version 3.2.1 Release NotesNew Supported Devices

77110 -- QUEST RSC1000 HVAC Controller Phase I Integration

Version 3.2.1 includes the first phase of integration of the QUEST RSC1000 HVAC controller. This supports basic monitoring including alarms, key measurements, and status information. Full support and control will follow in Phase II in an upcoming version.

The following is a sample configuration:

config site module Tower

application HVACMonitoring enable

application EnvironmentalMonitoring enable

config site network-element hvacSystem

type QuestRSC1000HVACSystem

param deviceIp 192.168.1.100

76187 -- Support for Delta Rectifier with Orion Controller

Version 3.2.1 supports the Delta Rectifier with an Orion controller. This includes basic monitoring including alarms, key measurements, and status information.

The following is a sample configuration:

config site module Tower

application RectifierMonitoring enable

application ACPowerMonitoring enable

application BatteryMonitoring enable

application DCPowerMonitoring enable

config site network-element rectifier

type DeltaOrionRectifier

param deviceIp 192.168.1.100

77114 -- Support for GE Infinity M/S Rectifier

Version 3.2.1 supports the M/S model of the GE Infinity Rectifier. This includes basic monitoring including alarms, key measurements, and status information.

The following is a sample configuration:

config site module Tower

application RectifierMonitoring enable

WESTELL.COM

1-800-377-8766

Page 4

Application Package Version 3.2.1 Release NotesNew Features

application ACPowerMonitoring enable

application BatteryMonitoring enable

application DCPowerMonitoring enable

config site network-element rectifier

type GEInfinityRectifier

param deviceIp 192.168.1.100

77115 -- DeviceAgent Monitoring Support for Westell Model DSP85 Repeater

Version 3.2.1 uses the DeviceAgent feature to provide basic monitoring support for the Westell DSP85 Digital Repeater component of an in-building wireless system. Contact Westell, Inc. Technical Services for the necessary DeviceAgent profile document.

77155 -- Support for Elkor WattsOn Mark II

Version 3.2.1 supports the Elkor WattsOn Mark II AC power meter. This includes collection and reporting of key measurements.

The following is a sample configuration:

config site module Tower

application ACPowerMonitoring enable

config site network-element mainsPower

type ElkorMarkIISplitPhasePowerMeter

param modbusAddress 1

param controller 'serial 2'

Note: The ElkorMarkIIThreePhasePowerMeter type also is available for monitoring three-phase power.

New Features

77100 -- Changes to Alarms Affecting Uptime

Version 3.2.1 makes the following changes to alarms which affect DAS uptime calculations:

WESTELL.COM

Page 5

1-800-377-8766

Application Package Version 3.2.1 Release NotesNew Features

All ODU Optic Module and RDU DL Output Low 1 alarm types will now be reported as outages when calculating uptime. ODU Optic Module alarm types also will display as a higher priority level in Optima Site View than previously.

All Neutral Host GPS alarm types will be reported as Priority 1 in Optima Site View.

For the JMA Teko, the following alarms will now be included in uptime calculations:

Laser Fault

Mains Fault

Rx Optical High

Rx Optical Low

77123 -- Device Agent Static NE Attributes

Version 3.2.1 enhances the Device Agent feature by allowing static NE attributes to be set for the network element. These attributes will include vendor, model, softwareVersion, firmwareVersion, hardwareVersion, and serialNumber.

77139 -- Tower Light Versions Set As NE Attributes

Version 3.2.1 presents tower light versions as NE attributes. Tower light versions are no longer presented as informational alarms. See the example below:

WESTELL.COM

1-800-377-8766

Page 6

Application Package Version 3.2.1 Release NotesNew Features

Figure RN-321-1 Tower light versions shown under the NE Attributes tab in Optima Prime

77213 -- Add measurements to the Basler Generator Management

Version 3.2.1 collects the following measurements from the BaslerDGC2020Generator:

BatteryVoltage

CoolantTemperature

EngineRunHours

OilPressure

RPM

Tower Light version

WESTELL.COM

Page 7

1-800-377-8766

Application Package Version 3.2.1 Release NotesNew Firmware Support

New Firmware Support

77101 -- Support for Commscope ION-U firmware 1.80

Version 3.2.1 supports Commscope’s ION-U firmware version 1.80.

Fixes

76511 -- Attribute Updates on MobileAccess SC-450

Version 3.2.1 includes a correction so that the softwareVersion attribute is updated on inventory sync after an SC-450 software update.

77276 -- Non-printable characters in JMA subrack name cause sync failure in Optima

Certain non-ASCII characters read from name fields on a JMA Teko DAS could prevent that system from being synchronized in Optima. Non-ASCII characters are now stripped.

Known Issues

77277 -- SPX Vanguard SNMP Tower Light does not support discrete alarming

The SPXVanguardSNMP Tower Light was originally designed for use in Direct Connect where discrete alarms are not supported. It is possible that users could configure this type in a Remote-monitored site. Version 3.2.1 is able to monitor the Vanguard via SNMP and report alarms successfully on a Remote. However, it would not fall back to discrete alarming during loss of intelligent communication. This is common functionality in the other Tower Light types

The discrete alarm fallback will be added to the SPXVanguardSNMP Tower Light type in a future version.

WESTELL.COM

1-800-377-8766

Page 8

Application Package Version 3.2.1 Release NotesApplication Package Version 3.2.1 Device Compatibility Information

Application Package Version 3.2.1 Device Compatibility InformationWestell has pre-configured application support to monitor and manage the following network elements.

Vendor Model/Variant Version(s)

In-B

uild

ing

Ant

enna

Sys

tem

s an

d D

AS

Corning SC-450 7.0, 7.2

Commscope

ION/MMC Plus ION-M Linux 6.50.0, 7.20.0

ION/MMC Plus ION-M Windows 5.30.0

ION/RMC1600 ION-M Linux 6.50.0, 7.0.1, 7.10, 7.20

ION/RMC1600 ION-M Windows 6.50.0, 7.20.0

ION/RMC1600 ION-U Linux 1.64.1, 1.70.0, 1.75.0, 1.80.0

ION/TSUN1/2 ION-B 5.1.1, 5.1.2

ION/TSUN4 ION-M Linux 6.50.0, 7.20.0

ION/TSUN4 ION-M Windows 5.30.0

JMA Wireless Teko 3.2.0

Microwave Photonics OFW3478

SOLiD DMS-1200 4.2.0, 6.1.0, 6.1.1

TE Connectivity FlexWave Prism 8.1.0, 8.1.7

Westell UDIT 1.03.00, 1.03.01, 1.04.02, 2.00.01A, 2.00.02

Zinwave 3000 4.5, 4.6

WESTELL.COM

Page 9

1-800-377-8766

Application Package Version 3.2.1 Release NotesApplication Package Version 3.2.1 Device Compatibility Information

Tow

er L

ight

s

Dialight

A0-A1 Style A.1, A.2

High Intensity A.31, A.40, A.41, A.42

Medium Intensity B.6, B,8, B.10, B.61, B.63

Medium Intensity Red A.6, A.7

Medium Intensity Small Red A.1, A.2

Red Only A1-A6 Style A.6, A.7

SPX Flash Technology

Eagle 4747/9038

Eagle Ethernet 4747/9038

LED Jun 26 2012 10:47:38

3630XX Jun 26 2012 10:47:38

9038XX 4747/9038

Vanguard 2.7, 2.8, 2.9, 3.0, 3.1, 3.2

Vanguard Ethernet 2.7, 2.8, 2.9, 3.0, 3.1, 3.2

Vanguard SNMP 3.3

Rect

ifier

s an

d U

PS

APC Galaxy 500 GDENA95300IC303

Delta Orion 6.50B17

Eaton 9130 4.30, 4.32, 4.34, 4.36, 4,38

Eltek SmartPack 4.6, 4.7, 4.8, 4.9, 4.10

Emerson Emerson Rectifier 4.00, 4.02, 4.04, 4.10, 4.21

GE Infinity M/S with NE843A Slot Controller

3.3.24 (pending validation)

Huawei SMU v500R001C20SPC901T

ZTE ZXDU

Vendor Model/Variant Version(s)

WESTELL.COM

1-800-377-8766

Page 10

Application Package Version 3.2.1 Release NotesApplication Package Version 3.2.1 Device Compatibility Information

HVA

C Co

ntro

llers Airsys ASLLC.2 13B64

BardMC4001 2.7 (pending validation)

MV5000 2.7 (pending validation)

Marvair CommStat4 v62

Quest Controls RSC 1000 0.6.4.4 (pending validation)

Gen

erat

ors

and

Gen

erat

or C

ontr

olle

rs

Basler DGC-2020 3.17.02

Deep Sea Electronics 521052205220/73207320

6.2a6.2a

9.x.x

Generac

EPanel

EPanel with Annunciator

H100 3.4-4.0

HTS 4.0

HTS Ethernet 4.0

Intellilite AMF25 1.4

Kohler DEC3000 4.04

LovatoEXM10

RGK60 42

Vendor Model/Variant Version(s)

WESTELL.COM

Page 11

1-800-377-8766

Application Package Version 3.2.1 Release NotesApplication Package Version 3.2.1 Device Compatibility Information

Page 12

Pow

er E

quip

men

t and

Sen

sors

Acrel PZ Series

Alpha TechnologiesAMPS24 3.13

FXM 2.00.01

BatteryDAQ 2402W2/M6

CCS WattNode

Elkor

WattsOn Split Phase

WattsOn Three Phase

WattsOn Mark II

FenceHawk RG-7781

ForlongDRT-301C

DRT-301C2

GreystoneRH310A02C2E6

RH310A03C2A6

iSnail

VC

VC10

VC25

Measurlogic DTS DC

Standardel DPS520

VoltServerMGT100 3.0.0-0

MGT500 1.0.0

Dev

ice

Age

nt-

Supp

orte

d

Dantel WebMon smart site controller

DPS Telecom NetGuardian alarm collector G45

Westell DSP85 Repeater 3.0.9 REL

Vendor Model/Variant Version(s)

WESTELL.COM