Application Notes for Frequency Division Multiplex System Testing with ET 92
To learn more click on note!
Basic, Super & Master Group
Voice Frequency Noise
END to END Measurements
Pilot Level Measurement
Noise Level Measurement
Level Measurement in Tracking Mode
Impulsive Noise Measurement
Psophometric Noise Measurement
Frequency Response Test with MTTS
Group Delay Distortion
Micro Interruption Analysis
Jitter and Frequency Difference
ELEKTR NIKA
Signal Level Measurement in Signal Level Measurement in Transmitter Tracking Mode ofTransmitter Tracking Mode of ET 9ET 922
Changing the transmitter frequency (Tx) the receiver automatically follows the change according to the selected rule:Rx=CARRIER+Tx or CARRIER-Tx
ELEKTR NIKA
Noise Level Measurement at Master Group with ET 92
ELEKTR NIKA
Pilot Level Measurement at Super Group with ET 92
ELEKTR NIKA
Pilot Frequency Allocation Schematics
ELEKTR NIKA
Psophometric Noise Level Measurement with ET 92
Display format up to 1 min Display format over 1 min
ELEKTR NIKA
Impulsive Noise Measurement with ET 92
Display format up to 30 sec Display format over 30 sec
An impulse is counted when the received noise signal exceeds a preset threshold for more than 500 ns
ELEKTR NIKA
Frequency Response Test of ET 92 with MTTS Method
MTTS METHOD:The transmitter generates 36 test tones ■ Frequency range: 100 to 3600 Hz ■ Frequency step: 100 Hz ■ Level: -20 dBm / frequencyThe receiver measures the 36 test tones simultaneously
ADVANTAGES: ■ No synchronisation is necessary between the two instruments ■ The measuring time is shorter than that of other methods
ELEKTR NIKA
Micro Interruption Analysis with ET 92
An interruption is detected when the level of test tone drops below a designated threshold for
more than 0,6 ms. The detected interruptions are included into five categories by duration
▼Click here to see the test resultsIn graphic and numeric forms
ELEKTR NIKA
Detailed Results of Micro Interruption Analysis
All the test results are available also in numeric form and they can be transferred to PC via USB interface.
ELEKTR NIKA
Group Delay Distortion Measurement with ET 92
ET 92 applies the multi tone test method described in Recommendation ITU-T O.81 Appendix IThe transmitter generates 36 test tones ■ Frequency range: 100 to 3600 Hz ■ Frequency step: 100 Hz ■ Level: -20 dBm / frequencyThe receiver measures the 36 test tones simultaneously
ELEKTR NIKA
Phase Jitter and Frequency Difference Measurement
ET 92 performs jitter and frequency error measurements simultaneously according to Recommendation ITU-T O.91That measurement needs two instruments connected to the ends of the tested line.■ One of them transmits jitter free quartz accurate 1020 Hz test tone■ The other one receives and evaluates it