5
ANUJ PANDEY Contact No.: +91- 7500669135 / +91-8720847502 E-Mail: [email protected] Mechanical Quality Engineer with ASNT Level-II certification in NDT, having 8 years of Working Experience Professional Snapshot A seasoned professional with nearly 08years’ experience in Quality Control & Assurance in EPC construction Company. Associated with Isgec Heavy Engineering Ltd., Noida as Sr.Engineer- Quality Control & Assurance; managing entire spectrum of Quality Assurance / Inspection activities at site. Adroit in managing overall inspections in construction of Boiler (Steam Generator) along with boiler auxiliaries like fans, pumps, DG sets, compressors & pipe lines with a view to enhancing the construction quality, eliminating obsolescence and achieving excellence through optimum utilisation of modern inspection tools & Procedures. Thorough experience of inspections at Oil & Gas industry, Power Plant sector including Rotary & static equipment. Well-versed with API, AWS, IBR & ASME guidelines for improving construction quality and approaches for quality management & assurance. An ASNT level-II certified inspector for Radiography Test, Ultrasonic Test, Magnetic Particle Test & Dye penetrant Test. Occupational Contour Since Oct’10 Isgec Heavy Engineering Ltd., Noida Sr.Engineer Spearheading all the Quality Management activities at sites- NDT Inspections (RT, UT, MPT, PMI& DPT), Stage inspections like Fit up, Welding, Hydro Test, Leak Test by Smoke, for Boiler Pressure Parts, Alignment of Rotary & Static Equipments, Preparing Test Packs, Loop Files, Line History Sheets, NDT Reports like RT, UT, PT, MT in prescribed formats, Welding Procedure Qualification & Welder Qualification and keeping records of the same, Qualification of all NDT Procedures by PMC/Client. Carried out In-Service tapping (Hot Tapping of Oil, Gas & Steam Pipe Lines) including angle tap of Flare piping. Completed Projects with Isgec:-

anuj cv

Embed Size (px)

Citation preview

Page 1: anuj cv

ANUJ PANDEYContact No.: +91- 7500669135 / +91-8720847502 E-Mail: [email protected]

Mechanical Quality Engineer with ASNT Level-II certification in NDT, having 8 years of Working Experience

Professional Snapshot

A seasoned professional with nearly 08years’ experience in Quality Control & Assurance in EPC construction Company.

Associated with Isgec Heavy Engineering Ltd., Noida as Sr.Engineer- Quality Control & Assurance; managing entire spectrum of Quality Assurance / Inspection activities at site.

Adroit in managing overall inspections in construction of Boiler (Steam Generator) along with boiler auxiliaries like fans, pumps, DG sets, compressors & pipe lines with a view to enhancing the construction quality, eliminating obsolescence and achieving excellence through optimum utilisation of modern inspection tools & Procedures.

Thorough experience of inspections at Oil & Gas industry, Power Plant sector including Rotary & static equipment.

Well-versed with API, AWS, IBR & ASME guidelines for improving construction quality and approaches for quality management & assurance.

An ASNT level-II certified inspector for Radiography Test, Ultrasonic Test, Magnetic Particle Test & Dye penetrant Test.

Occupational Contour

Since Oct’10 Isgec Heavy Engineering Ltd., Noida Sr.Engineer

Spearheading all the Quality Management activities at sites- NDT Inspections (RT, UT, MPT, PMI& DPT), Stage inspections like Fit up, Welding, Hydro Test, Leak Test by Smoke, for Boiler Pressure Parts, Alignment of Rotary & Static Equipments, Preparing Test Packs, Loop Files, Line History Sheets, NDT Reports like RT, UT, PT, MT in prescribed formats, Welding Procedure Qualification & Welder Qualification and keeping records of the same, Qualification of all NDT Procedures by PMC/Client.

Carried out In-Service tapping (Hot Tapping of Oil, Gas & Steam Pipe Lines) including angle tap of Flare piping.Completed Projects with Isgec:-

2X300 TPH CFBC Boiler at HPCL-Mittal Refineries Ltd., Bathinda, Punjab (Since April 2015)Scope of Project- Construction of Boiler, Economiser coils, Super Heater coils, Soot Blowers, ESP, De-Aerator, FD Fans, SA Fans- 2 Nos., Boiler Feed Water Pumps, Burners- 4 nos., Air Heater- 2Nos., ESP- 2Nos., Deaerator- 1No.

1X160 TPH Oil/Gas Fired Boiler at Bharat Oman Refineries Ltd., Bina (Sep 2013 to April 2015)Scope of Project- Construction of Boiler, Economiser coils, Super Heater coils, Soot Blowers, ESP, De-Aerator, FD Fans- 2 Nos.(1 Motor & 1 Turbo Driven), SA Fans- 2 Nos.(1 Motor & 1 Turbo Driven), Boiler Feed Water Pumps- 2 Nos (1 Motor & 1 Turbo Driven), Seal air fans- 2 nos., Scanner cooling fans- 2nos., Burners- 4 nos., Air receivers- 2nos. (1 HP & 1 LP), Compressors- 3 Nos.(1 HP & 2 LP compressors), Knock Out Drum- 2Nos.(1 Flare KOD & 1 fuel Gas KOD), RFO Transfer pump- 1 No., Fuel Oil transfer pump- 2Nos.(Motor & Turbo driven), Slop transfer pump- 2Nos. Blow down transfer pump- 2Nos. DM Water transfer pump- 2Nos.(Motor & Turbo driven), Oil

Page 2: anuj cv

& Gas pipe lines of approx. 8 Kms., Steam & Water pipe lines of approx. 6Kms., Day oil storage tank- 1No., DM Water storage tank-1No., Deaerator- 1No., Cold tapping steam & water at existing pipelines- 26Nos., Hot tapping of oil & gas at existing pipelines- 7 Nos.

Job Profile:- Taking over foundation from civil deptt. by mutual inspection, Ground inspection of structure column, alignment check of column after erection, ground inspection of Pressure Parts with client & IBR and making IMR for the same, fit-up & weld visual inspection along with IBR & client, raising daily inspection call to client, welding procedure qualification & welders qualification with client, stage inspection during erection of rotary & static equipments, final coupling alignment inspection, Smoke test of boiler, Leak test of Air pre-heater, kerosene test of ducting & casing, boiler furnace alignment, stage inspection of LP, HP, MP & VHP piping, Hydro Test of boiler & Piping after completion of loop files (mechanical & NDT clearance), Carrying out Radiography at site as per IBR / Contract requirements, CARRYING OUR UT Test of welded joints, Carrying out stage Inspection during Refractory application at site, Carrying our PMI for all alloy steel, PWHT as per WPS / code requirements, Hardness test as per approved ITP / specification of EIL, all stage & final inspections as per ITPs, FQAP, making procedure for hot tapping, welding during hot tapping, welder qualification for hot tapping as per API code, all stage & final inspections as per ITPs, FQAP, preparing ITPs, preparing welding & NDT procedures, preparing formats for approval & qualification.

2X170 TPH Gas Fired Boiler at GAIL India, Pata, UP (may 2012 to Sep2013)

Scope of Project- Construction of Boiler, Economiser coils, Super Heater coils, Soot Blowers, ESP, De-Aerator, FD Fans- 2 Nos. (Motor & Turbo Driven with clutching & declutching system) , SA Fans- 2 Nos. (Motor & Turbo Driven with Clutching & Declutching system), Boiler Feed Water Pumps- 3 Nos (1 Motor & 2 Turbo Driven), Blow down coolers- 2nos. (Heat Exchangers), Seal air fans- 4 nos., Scanner cooling fans- 4nos., Burners- 8 nos., Nitrogen vessel- 1No., Air receivers- 2nos., Dump condenser- 4Nos., Knock Out Drum- 1No.

Job Profile:- Taking over foundation from civil deptt. by mutual inspection, Ground inspection of structure column, alignment check of column after erection, ground inspection of Pressure Parts with client & IBR and making IMR for the same, fit-up & weld visual inspection along with IBR & client, raising daily inspection call to client, welding procedure qualification & welders qualification with client, stage inspection during erection of rotary & static equipments, final coupling alignment inspection, Smoke test of boiler, Leak test of Air pre-heater, kerosene test of ducting & casing, boiler furnace alignment, stage inspection of LP, HP, MP & VHP piping including P91 material, Hydro Test of boiler & Piping after completion of loop files (mechanical & NDT clearance), Carrying out Radiography at site as per IBR / Contract requirements. Carrying out stage Inspection during Refractory application at site, Carrying our PMI for all alloy steel, PWHT as per WPS / code requirements, Hardness test as per approved ITP / specification of EIL, all stage & final inspections as per ITPs, FQAP, preparing ITPs, preparing welding & NDT procedures, preparing formats for approval & qualification.

1X190 TPH Travelling Grate- Coal & Baggase fired boiler at Kesar Enterprises Ltd., Bareilly.

Scope of Project:- Construction of Boiler, Economiser coils, Super Heater coils, Soot Blowers, ESP, De-Aerator, FD Fans- 2 Nos., ID Fans- 2 Nos., SA Fans- 2 Nos. & Boiler Feed Water Pumps- 2 Nos.Job Profile:- Taking over foundation from client by mutual inspection, Ground inspection of structure column, alignment check of column after erection, ground inspection of Pressure Parts with IBR, fit-up, weld visual inspection along with IBR & client, raising daily inspection call to client, qualifying welding procedure as per ASME section IX, welder qualification, stage inspection during erection of rotary & static equipments, final coupling alignment inspection, Smoke test of boiler, kerosene test of ducting & casings, Leak test of Air pre-heater, boiler furnace alignment, Hydro Test of boiler & Piping, Carrying out Radiography at site as per IBR / Contract requirements. Carrying out stage Inspection during Refractory application at site

2X425 TPH CFBC Boiler at Bhushan Energy, Angul, Orissa

Scope of Project:- Construction of Boiler, Economiser coils, Super Heater coils, Soot Blowers, ESP, De-Aerator, FD Fans- 2 Nos., ID Fans- 2 Nos., SA Fans- 2 Nos. & Boiler Feed Water Pumps- 2 Nos.

Job Profile:- Taking Over foundation from client by mutual inspection, Ground inspection of structure column, alignment check of column after erection, ground inspection of Pressure Parts (Carbon Steel, Alloy Steel- P91) with IBR, fit-up, weld visual inspection along with IBR & client, raising daily inspection call to client (FIN), qualifying welders as per WPS.

1X50 TPH AFBC Boiler- Rice Husk Fired Boiler at Best Foods Ltd., Karnal, Haryana

Scope of Project:- Construction of Boiler, Economiser coils, Super Heater coils, Soot Blowers, ESP, De-Aerator, FD Fans- 2 Nos., ID Fans- 2 Nos., SA Fans- 2 Nos. & Boiler Feed Water Pumps- 2 Nos.

Job Profile:- Taking over foundation from client by mutual inspection, Ground inspection of structure column, alignment check of column after erection, ground inspection of Pressure Parts with IBR, fit-up, weld visual inspection along with IBR & client, raising daily inspection call to client, welders qualification, stage inspection during erection of rotary & static equipments, final coupling alignment inspection, Smoke test of boiler, Leak test of Air pre-heater, kerosene test of ducting & casings, boiler furnace alignment, Hydro Test of boiler & Piping,

Page 3: anuj cv

Carrying out Radiography at site as per IBR / Contract requirements. Carrying out stage Inspection during Refractory application at site

1X250 TPH CFBC Boiler at Visa Steel Ltd., Jajpur Road, Orissa.

Scope of Projec:- Construction of Boiler, Economiser coils, Super Heater coils, Soot Blowers, ESP, De-Aerator, FD Fans- 2 Nos., ID Fans- 2 Nos., SA Fans- 2 Nos. & Boiler Feed Water Pumps- 2 Nos.Job Profile- Stage inspection during erection of rotary & static equipments, final coupling alignment inspection, Hydro Test of Boiler & Piping, Carrying out Radiography at site as per IBR / Contract requirements, Leak test of Air pre-heater, and Carrying out stage Inspection during Refractory application at site

Jul’07 to Sep’10 H.V.EquipmentsPvt Ltd., Noida Engineer

Company Profile:- H.V.Equipments carries out Engineering, manufacturing & construction of Pneumatic Ash Handling System, Mill Reject Handling system, Dome valves, Steel Silos & Bag Filters

Job Profile:- Responsible for Quality Control activities at Noida workshop & sites. To carry out stage inspection as per approved FQAP, ITP, and procedures at workshop. Raising inspection call to client for inspection at workshop & site as per FQAP, carry out inspection at vendor shop for castings, machines material etc., developing QAPs & FQAPs for submission to client for approval, making inspection reports & protocols for all inspections carried out. Preparing full quality dossier for submission.

Academic & Other Credentials

Academics

B.E. in Mechanical with 63.1% marks from University of Rajasthan, Jaipur in 2007.

Others

Completed Short term training program in Quality Management System conducted byDNV. Level – II Certification from ASNT for RT, UT, MPT, DPT

Personal Dossier

Date of Birth: 06th May 1983

Permanent Address: 81, Asharfabad, Lucknow-226003, U.P.

Present Address: 20, HIG, SukhSagar, Ph.-I, Nizamuddin Colony, BHEL, Bhopal

Present CTC: Rs.7.9Lacs

Notice Period: 3 Months negotiable