Anti Condensation Heaters
2 3
Problem:Condensation forms due to fluctuating temperature, even in sealed enclo-sures. In combination with dust and aggressive gases condensation causes corrosion which results in stray currents and arcing. Too high a temperature, or for that fact too low a temperature, can also lead to serious component failure. The safety risk is enormous and the cost of operational delays as a consequence is incalculable.
Solution:Only constant optimum climatic conditions allow components to function properly. The right climate can be attained by a temperature and moisture control system. When tempera-tures are too low or when temperature differences (e.g. night / day) are large, heating is required. It may also be necessary to keep components cool by controlled ventilation.
Applications:Whether for telecommunications or traffic systems, power stations or outdoor plants, ATMs or parking control system, where electronics have to be protected against humidity, heat or cold, SAN’s comprehensive product range offers effective economical solutions.
Our Products:Conventional and PTC semi-conductor control panel heaters and fan-assist-ed heaters ranging from 5W to 1200W, as well as tropicalised and EX varia-tions. Temperature and humidity controls ranging from 0°C to 60°C (30° to 140°F) and 35% to 100% RH.A new filter fan series in EMC and standard versions with excellent performance and shielding characteristics. Panel lighting and accessories.
About us:We have been developing and producing innovative products for thermal management for more than twenty years. Our products are renowned for their reliability and long life, simplicity of use and high quality. Used and proven worldwide even under extreme conditions.
Thermal Management Products & Accessories from SAN successfully used worldwide
for control panels and enclo-sures
for traffic control and monito-ring systems in the transport industry
for high voltage swichtgear in outdoor and indoor substa-tions
system protction in the auto-motive industry
in transmitter stations of cel-lular phone networks
for motor control centres and control cabinets
2 3
Heating:Small semiconductor heater RCE 016 Series .................................................. 4Small semiconductor Heater RC 016 Series .................................................... 5Small semiconductor Heater HGK 047 Series ................................................. 6Small semiconductor Heater CSK 060 Series.................................................. 7Finned extruded Heater SAN-FXE ................................................................... 8Semiconductor Heater HG 140 Series ............................................................. 9Compact Fan Heater HGL 046 Series .............................................................. 10Hazardous area Heaer CREx 020 Series .......................................................... 11Electrical Direct Heater SAN-LP ....................................................................... 12Electrical Space Heater SAN-LP AF Ex Heater ................................................ 13Electrical Smart Heater SAN-SMLP ................................................................. 14Semiconductor Heater CS 060 Series ............................................................. 15Semiconductor Heater CSF 060 Series ........................................................... 16Small semiconductor Fan Heater CS 028 Series ............................................. 17Compact semiconductor Fan Heater CSL 028 Series ..................................... 18Electrical Smart Heater SAN-GSMLP .............................................................. 19Explosion proof Heater SP ............................................................................... 20Electrical Smart Heater..................................................................................... 21Electrical Smart-Space Ex Heater SM-*A ........................................................ 22Electrical Direct Ex Heater CS-*S ..................................................................... 23Electrical Direct Ex Heater CT-*A ..................................................................... 24Anti Condensation and Space Heater SAN-HEF ............................................. 25Space-saving Fan Heater HV 031 / HVL 031 Series ........................................ 26Semiconductor Fan Heater CR 027 ................................................................. 27Fan Heater with integrated thermostat or hygrostat CR 030 ........................... 28Fan Heater with integrated thermostat or hygrostat CR 130 ........................... 29Fan Heater with/without integrated thermostat CS 030................................... 30Fan Heater with/without integrated thermostat CS 130................................... 31Ventilating:Low maintenance Filter Fan FF 018 Series (21m3/to 102m3/h) ........................ 32-33Low maintenance Filter Fan FF 018 Series (200m3/h) ...................................... 34High-performance Filter Fan FF 018 Series (300m3/h) ..................................... 35High-performance Filter Fan FF 018 Series (550m3/h) ..................................... 36Outdoor Filter Fan FF 018 Series ..................................................................... 37Low noise Roof Filter Fan RFF 018 Series ....................................................... 38High-performance 19” Fan Tray LE 019 Series ................................................ 39Regulating and monitoring:Electronic Relay SM 010 (DC 24V + DC 48V) ................................................... 40Small, compact Thermostat KTO 011 / KTS 011 ............................................. 41Fix Thermostat FTO 011 / FTS 011 .................................................................. 42Dual Thermostat ZR 011 .................................................................................. 43Dual Thermostat FTD 011 ................................................................................ 44Mechanical Thermostat FZK 011 ..................................................................... 45Electronic Thermostat ET 011 (DC 24V) ........................................................... 46Ex FixTherm96 Thermostat .............................................................................. 47FixTherm96 Thermostat ................................................................................... 48Mechanical Hygrostat MFR 012 ....................................................................... 49Electronic Hygrostat EFR 012 .......................................................................... 50Electronic Hygrottherm ETF 012 ...................................................................... 51Hazardous area Thermostat REx 011 Series ................................................... 52Lighting:Slimline Lamp with on/off switch SL 025 Series .............................................. 53Slimline Lamp with movement sensor SL 025 Series ...................................... 54Dual Lamp with on/off switch DL 026 Series ................................................... 55Dual Lamp with movement sensor DL 026 Series ........................................... 56Hand Lamp with lamp holder DL 026 Series.................................................... 57Compact Lamp KL 025 Series ......................................................................... 58Accessories:Electrical Sockes SD 035 Series ................................................................... 59Pressure compensation Device DA 084 ........................................................... 60Pressure compensation Device DA 284 ........................................................... 61Pressure compensation Device DA 284 (stainless steel) ................................. 62Self-adhesive appliance holder SANOFIX ........................................................ 63
Calculation of temperature control in encloseures ........................................... 64
Indication of measurements in m.m. Errors and omissions excepted. Specifications are subject to change with-out notice. Suitability of the products for their intended use and any associated risks must be determined by the end customer/buyer in their final application.
Contents:
4 5
• Temperature limiting• Wide voltage range• Dynamic heating up• Energy saving• Compact
Small heaters designed to prevent condensation and to ensure a minimum operating temperature in small enclosures.
Small semiconductor
Heater - RCE 016 Series
Operating voltage 12-240V AC/DC* (min. 110V, max. 265V)Heating element PTC resistor, temperature limitingHeater body AluminumMounting See AccessoriesFitting position VariableDimensions Length 45mm, Ø10mmOp./storage temperature -45 to +70ºC Prot. type / Prot. class IP32 / II (double insulated)Approvals VDE + UL File No. E150057Accessories Mounting clips (see illlustration)Note Other voltages on request*) Op. with voltages below AC/DC 140V reduces heating performance by approx. 10%.
Technical Data:
Art. No. Voltage Heating capacity* Inrush current max. Surface temp. (approx.) Connection Weight (approx.)82240 120-240 5W 2.0A 165˚C 2xAWG 22 sheathed cable (silicone) 20g82241 12-36 5W82242 120-240 9W 2.5A 175˚C 2xAWG 22 sheathed cable (silicone) 20g82243 12-36 10W
* At 20ºC (68˚F) ambient temperature.
L
N
5W, 9W
Example of connection
Mounting clips Art. No. (1 packing unit = 2 pieces)
Connection 2xAWG 22 sheathed cable (silicone)
Thermostat KTO 011(contact breaker, normally closed)
Heater RCE 016
4 5
• Temperature limiting• Wide voltage range• Dynamic heating up• Energy saving• Compact
These small heaters are designed to prevent condensation and to ensure a minimum operating temperature in small enclosures.
Small semiconductor
Heater - RC 016 Series
Operating voltage 120-24V AC/DC* -(min. 110V, max. 265V)Heating element PTC resistor, temperature limitingHeater body Aluminium, anodisedMounting Screw fixingFitting position VariableOp./storage temperature -45 to +70ºC (-40 to +158˚F)Prot. type / Prot. class IP32 / II (double insulated)Approvals VDE + UL File No. E150057Note Other voltages on request*Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Technical Data:
8W, 10W, 13W
Art. No. Heating capacity* Inrush current max. Surface temp. (approx.) Connection Weight (approx.)82244 8W 2.0A 150˚C 2xAWG 18 stranded wire 20g82246 10W 2.5A 155˚C 2xAWG 22 sheathed cable (silicone) 28g82248 13W 3.0A 170˚C 2xAWG 22 sheathed cable (silicone) 34g82243 8W 3.7A 134˚C 2xAWG 18 stranded wire 20g82247 10W 5.7A 132˚C 2xAWG 22 sheathed cable (silicone) 28g82249 13W 10.0A 148˚C 2xAWG 22 sheathed cable (silicone) 34g
* At 20ºC (68˚F) ambient temperature.
Art. No. : Connection 2xAWG 18 stranded wire
Art. No. : Connection 2xAWG 22 sheathed cable (silicone)
Art. No. : Connection 2xAWG 22 sheathed cable (silicone)
L
N
Example of connection
Thermostat KTO 011(contact breaker, normally closed)
Heater RC 016
6 7
50 25
12
30
0L
• Dynamic heating up• Energy saving• Wide voltage range• Temperature limiting• Clip fixing
The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured.
Small semiconductor Heater - HGK 047 Series
Heating element PTC resistor, temperature limitingHeater body Extruded aluminium profile, anodisedMounting Clip for 35mm DIN rail, EN 60715Fitting position VerticalOp. / Storage temp. -45 to +70ºCProt. type / Prot. class IP54 / I (earthed)Accessories Screw fixing
Technical Data:
Art. No. Operating voltage Heating capacity1)
Inrush current max.
Length(L)
Weight(approx.)
Connection Approval
83250 120-240V AC/DC2) 10W 1.0A 50mm 0.1kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE83251 120-240V AC/DC2) 20W 2.5A 60mm 0.2kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE83252 120-240V AC/DC2) 30W 3.0A 70mm 0.2kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE83253 110-120V AC/DC 10W 1.0A 50mm 0.1kg 3 x AWG 20 x 300mm sheathed cable UL File No. E15005783254 110-120V AC/DC 20W 1.5A 70mm 0.2kg 3 x AWG 20 x 300mm sheathed cable UL File No. E15005783255 110-120V AC/DC 30W 1.5A 100mm 0.2kg 3 x AWG 20 x 300mm sheathed cable UL File No. E1500571) at 20°C ambient temperature; 2) (min. 110V, max 265V) Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
L
N
10W to 30W
Example of connection
Clip for35mm DIN rail
Thermostat KTO 011(contact breaker, normally closed)
Heater HGK 047
6 7
• Low surface temperature• Double insulated (plastic housing)• Wide voltage range• Temperature limiting• Dynamic heating up• Clip fixing
The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. The heaters are designed for permanent operation.
Touch-Safe Small Semiconductor
Heater - CSK 060 Series
Operating voltage 120-24V AC/DC* -(min. 110V, max. 265V)Heating element PTC resistor, temperature limitingSurface temperature <85ºC (according to VDE 0100) except upper protective grilleConnection 2-pole terminal 2.5mm2, torque 0.8Nm max.Casing Plastic according to UL94 V-0, blackDimensions 98 x 38 x 75mmMounting Clip for 35mm DIN rail, EN 60715Fitting position VerticalOp./storage temp. -45ºC to +70ºCProt. type / Prot. class IP20 / II (couble insulated)Approvals VDE + UL File No. E150057 (according to UL499 in combination with
UL508A)Note Other voltages on request*Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Technical Data:
Art. No. Heating capacity* Inrush current max. Weight (approx.)10W 1.0A 0.2kg20W 2.5A 0.3kg
* At 20ºC (68˚F) ambient temperature.
10W, 20W
Example of connection
Thermostat FTO 011(contact breaker, normally closed)
Heater CSK 060
8 9
Finned Extruded Enclosure Heater Type SAN-FXE
The FXE range of heaters is designed specifically for frost protection, an-ti-condensation and temperature control within Zone 1 and Zone 2 Ha-zardous Areas. The FXE delivers a constant power output and comes com-plete with mounting bracket and a 1.5 metre flying lead.
Features • Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost
and IECEx.• Compact design, requires minimal space.• Optional over-temperature protection.• Black anodized convective surface.• Standard product available with short delivery times.• Suitable for ambient temperatures -50°C up to +80°C.
Typical Applications:Control / monitoring panelsInstrumentation cabinetsCondensation preventionTemperature fluctuationsFrost protectionMotor enclosures
CertificationIECEx & ATEX certified Ex II 2 G/D, Ex d IIC (Gas) T3-T4 Gb, Ex t IIIC (Dust) T200-T135°C Db, EN/IEC60079-0 & EN/IEC60079-1 & EN/IEC 60079-31
ExtrusionFinned Aluminium, Anodized Matt Black
Mounting:Vertically Mounted by Bracket or Rail
Voltage:Up to 254VAC
Rating:Available in 30, 50, 75 & 100 Watts
ControlsIf required, heaters can be supplied with a range of remote mounted thermostats.
Element:18mm dia 321 St/Steel cartridge element with 1.5m silicone flex cable.
Weather protection:IP6X
8 9
• Pressure clamp connectors• Dynamic heating up• Wide voltage range• Temperature limiting• Energy saving• Clip fixing• Quick installation
These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature may not fall below a minimum value. The aluminium profile heater body design has a chimney effect and distributes the heat evenly. The pressure clamp connectors save time and simplify installation.
Semiconductor Heater - HG 140 Series
Operating voltage 120-240V AC/DC* (min. 110V, max. 265V)Heating element PTC resistor, temperature limitingHeater body Extruded aluminium profile, anodisedConnection 3 pressure clamps for stranded wire 0.5-1.5mm² (with wire end ferrule)
and rigid wire 0.5-2.5mm2
Connection casing Plastic according to UL94 V-0, blackMounting Clip for 35mm DIN rail, EN 60715Fitting position VerticalOp./storage temperature -45 to +70ºC Prot. type / Prot. class IP20 / I (earthed)Approvals VDE + UL file E150057Accessories Screw fixing*Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Technical Data:
Art. No. Heating capacity* Inrush current max. Length (L) Weight (approx.)83190 15W 1.5A 65mm 0.3kg83191 30W 3.0A 65mm 0.3kg83192 45W 3.5A 65mm 0.3kg83193 60W 2.5A 140mm 0.4kg83194 75W 4.0A 140mm 0.5kg83195 100W 4.5A 140mm 0.5kg83196 150W 9.0A 220mm 0.7kg
*At 20ºC (68˚F) ambient temperature.
15W to 150W
10 11
Art. No. Approval Operating voltage Heating capacity* Length (L) Weight (approx.)83256 VDE AC 230V, 50-60Hz 250W 170mm 1.0kg83257 VDE AC 230V, 50-60Hz 400W 252mm 1.3kg
UL AC 115V, 50-60Hz 250W 170mm 1.0kg83257-1 UL AC 115V, 50-60Hz 400W 252mm 1.3kg
UL AC 230V, 50-60Hz 250W 170mm 1.0kg UL AC 230V, 50-60Hz 400W 252mm 1.3kg
*At 20ºC (68˚F) ambient temperature.
• Compact design• Temperature safety cut-out• Clip fixing• Long service life• Maintenance free
This compact fan heater prevents the formation of conden-sation. The integrated axial fan provides forced air circula-tion and so guarantees an even temperature in enclosures. A built-in temperature safety cut-out switches the heater off, in the event of fan failure.
Compact
Fan Heater - HGL 046 Series
Operating voltage AC 220-240V, 50-60HzAC 110-120V, 50-60HzOther voltages on request (e.g. AC/DC 48V)
Heating element Resistance heaterTemp. safety cut-out To protect against overheating in case of fan failure.Heater body Extruded aluminium profile, anodisedSurface temperature Max 75°C (400W)Axial fan Ball bearing service life 50 000h at 25°C (77°F)
airflow 35m³/h, free flowConnection 3-pole clamp for 2.5mm²Mounting Clip for 35mm DIN rail, EN 50022Fitting position Preferably verticalOp./storage temperature -40 to +70ºC (-40 to +158˚F)Prot. type / Prot. class IP20/I (earthed)Approvals VDE, UL file E150057
Technical Data:
10 11
• Large convection surface• Clip fixing• Ready for use• Maintenance free
Compact convection heater for use in areas with explosion hazard for prevention of formation of condensation, temperature fluctuations and for protection against frost in transmitter housings, switch cabinets and measur-ing equipment.
Hazardous area
Heater - CREx 020 Series
Explosion protection acc. to EN LCIE (Laboratoire Central des Industries Electriques)Conformity certificate 01 ATEX 6073/03, LCIE No 06 ATEX Q8011, IECEx LCI 07, 0020Heating element High performance cartridgeHeater body Aluminium profile, black anodisedConnection Si HF-JZ 3 x 0.75mm2 cable, length 1mConnection PE 4mm2
Mounting Clip for 35mm DIN rail, EN 60715Fitting position VerticalOperating/storage temperature -20 to +40ºC / -45 to 70ºCProtection type /Protection class IP65 / I (earthed)
Technical Data:
Art. No. Operating voltage Heating capacity* Ex protection type Surface temperature Length (L) Weight (approx.)83197 230-240VAC 50W d IIC T5 - Ex tD A21 IP6X T100˚C 100˚C 150mm 1.3kg83198 230-240VAC 100W d IIC T4 - Ex tD A21 IP6X T135˚C 135˚C 180mm 1.5kg
110-120VAC 50W d IIC T5 - Ex tD A21 IP6X T100˚C 100˚C 150mm 1.3kg 110-120VAC 100W d IIC T4 - Ex tD A21 IP6X T135˚C 135˚C 180mm 1.5kg
50W, 100W
Clip can alternativelybe fixed on long side
Hazardous area Thermostat REx 011see page 40
12 13
Electrical Direct Heater
SAN-LP Heater
Direct-heaters for Hazardous locations, designed for direct mounting onto e.g. manifolds etc.• Freeze protection• Anti-condensation• Temperature maintenance
Features and Advantages
• Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx.• Self-limiting heating elements• Small dimensions• No moving parts, no maintenance required therefore long lifetime • Suitable for T4 and T3 classifications• Can be used for 110 / 240 VAC/DC
Description
All Cameo Heaters are designed around self-limiting heating elements. These self-limiting semi-conductor elements are saving power consumption. Our Cameo Direct-heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
Optional body #5 : 4 holes diam. 5,2 mm. available in Aluminium and SS range For easy mounting, at no extra charge
Alternative 316 Stainless Steel heaters can be delivered for the 100-10 Watt range. Also possible is an aluminium body with four holes drilled through (body #5), for easy mounting.Please see below for further technical data.
Range
LP-1A T3 ca. 115 °C Surface temperature 100-10 WattLP-2A T4 ca. 105 °C Surface temperature 100-10 WattLP-3A T4 ca. 90 °C Surface temperature 100-10 Watt LP-4A T4 ca. 70 °C Surface temperature 100-10 Watt
High Power model:
LP-0AHP T3 ca. 130 °C Surface temperature 200-20 Watt
* these temperatures are measured at 20 °C ambient temperature.
12 13
Electrical Space Heater
SAN-LP AF Ex Heater
Space-heaters for Hazardous locations, designed for :• Freeze protection• Anti-condensation• Temperature maintenance
Features and Advantages
• Self-limiting heating elements• Small dimensions• No moving parts, no maintenance required therefore
long lifetime • Suitable for T4 and T3 classifications• Can be used for 110 / 240 VAC/DC
Description
All Cameo Heaters are designed around self-limiting hea-ting elements. These semi-conductor elements are saving power consumption. Our Cameo Space-heaters heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
In other situations, if the equipment, e.g. analyzers, it is nor-mal practice to use our Space-Heters in combination with our Fix-Therm96 thermostats (range from 10°C up to 135°C)
Do not cover the fins to guarantee free convection.
Range
LP-1AF T3 ca. 115 °C Surface temperature 100-10 WattLP-2AF T4 ca. 105 °C Surface temperature 100-10 WattLP-3AF T4 ca. 90 °C Surface temperature 100-10 Watt LP-4AF T4 ca. 70 °C Surface temperature 100-10 Watt
* these temperatures are measured at 20 °C ambient tempe-rature.
Power consumption 100-10 WattElectrical cable 3x1 sqmmMaterial cable braided silicone, optional: non-braided cableStandard length approx. 1 mtr. Other lengths optionalOther lengths To be specifiedOverall dimensions 164x100x60mm (LxWxH)Material black anodized aluminiumEX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°CCertification KEMA 01ATEX2124X and IECEx DEK 11.0017Protection degree IP66Voltage 110/240Ambient temp. range -60°C...+90°C
Technical Data:
14 15
Electrical Smart Heater for Space Heating
SAN-SMLP Ex Heater
Space-heaters for Hazardous locations, this compact model is designed for• Anticondensation• Freeze protection• Temperature maintenance• Small spaces
Features and Advantages• Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx.• Self-limiting heating elements• Small dimensions• No moving parts, no maintenance required therefore long lifetime • Suitable for T4 and T3 classifications• Can be used for 110 / 240 VAC/DC
Description
All SMART Space-heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption.
Our SMART Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96 thermostat as a maximum temperature protection, in the system. When required in other applications, e.g. analyzers, it is normal practice to use our SMART Space-heaters in combi-nation with our FixTherm96 thermostats (range from 10°C up to 135°C).
Do not cover the fins to guarantee free convection..
Range
SMLP-1A T3 ca. 115°C Surface temperature 100-10 WattSMLP-2A T4 ca. 105°C Surface temperature 100-10 WattSMLP-3A T4 ca. 90°C Surface temperature 100-10 WattSMLP-4A T4 ca. 70°C Surface temperature 100-10 Watt
High power model:SMLP-0AHP T3 ca. 130°C Surface temperature 200-20 Watt
* these temperatures are measured at 20 °C ambient temperature.
14 15
• Low surface temperature• Quick mounting due to clip fixing• Double insulated (plastic) • Wide voltage range• Small size
Touch-safe heater for the use in enclosures with electrical/electronical com-ponents. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the ac-cessible side surfaces of the housing are kept down as a result of the heater design. Our complete range of thermostats and hygrostats can directly be connected to the heater CS 060. This heater is also available in a version with plug-in thermostat requiring no additional wiring (C*SF 060). Both ver-sions are designed for permanent operation.
Operating voltage 120-240V AC/DC* (min. 110V, max. 265V)Heating element PTC resistor, temperature limitingSurface temperature <80ºC, except upper protective grilleConnection 4-pole terminal 2,5mm2, torque 0.8Nm max.Casing Plastic according to UL94 V-0, blackMounting Clip for 35mm DIN rail, EN 60715Fitting position VerticalOp./storage temperature -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)Approvals VDE + UL file E150057 (according to UL499
in combination with UL508A)Note Other voltages on request*Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Technical Data:
Art. No. Heating capacity1) Inrush current max. Air outlet temp.2) Dimensions Weight (approx.)50W 2.5A +86ºC 110 x 60 x 90mm 0.3kg100W 4.5A +120ºC 110 x 60 x 90mm 0.3kg150W 8A +145ºC 150 x 60 x 90mm 0.5kg
1)Ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille.
Touch-Safe Semiconductor
Heater - CS 060 Series
50
0
200
150
100
He
izle
istu
ng
(W)
-40 -20 0
Umgebungstemperatur (°C)
Leistungs-Umgebungstemperatur-DiagrammCS 160
20 40
Art. Nr. 16000.0-00
Art. Nr. 16010.0-00
Art. Nr. 16020.0-00
178
160
147
132
119122
110
102
9385
6661
55
5044
50W to 150W
Heating capacity / Ambient temperature diagram CS 060
Temperature (ºC)
Heater CS 060 Heater CS 060
Heater CS 060
ThermostatFTO 011
ThermostatFTO 011
Examples of connection
AC
AC
Hea
ting
capa
city
(W)
16 17
• Low surface temperature• Integrated thermostat• Quick mounting due to clip fixing• Double insulated (plastic)• Wide voltage range• Small size
Touch-safe heater for the use in enclosures with electrica/electronical com-ponents. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the ac-cessible side surfaces of the housing are kept down as a reslt of the heater design. This model with plug-in thermostat does not require additional wiring. The heaters are designed for the permanent operation. This heater is also available in a version without thermostat (CS 060).
Touch-Safe Semiconductor
Heater - CSF 060 Series
Operating voltage 120-240VAC* (min. 110V, max. 265V)Heating element PTC resistor, temperature limitingSurface temperature <80ºC, except upper protective grilleConnection 4-pole terminal 2.5mm2, torque 0.8Nm max.Casing Plastic according to UL94 V-0, blackMounting Clip for 35mm DIN rail, EN 60715Fitting position VerticalOp./storage temp. -20 to +70ºC / -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)Approvals VDE + UL File No. E150057 (acc. to UL499 in combination with UL508A)Note Other voltages on request*Op. with voltages below 140VAC reduces heating performance by approx. 10%
Technical Data:
Art. No. Heating capacity*
Inrush current max.
Air outlet temperature2)
Switch-off temperature3)
Starting temperature3)
Dimensions Weight (approx.)
50W 2.5A +86ºC +15ºC +5ºC 110 x 60 x 90mm 0.3kg50W 2.5A +86ºC +25ºC +15ºC 110 x 60 x 90mm 0.3kg100W 4.5A +120ºC +15ºC +5ºC 110 x 60 x 90mm 0.3kg100W 4.5A +120ºC +25ºC +15ºC 110 x 60 x 90mm 0.3kg150W 8A +145ºC +15ºC +5ºC 150 x 60 x 90mm 0.5kg150W 8A +145ºC +25ºC +15ºC 150 x 60 x 90mm 0.5kg
1)ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille; 3)tolerance of ±5K.
90
23
L60
50
0
200
150
100
He
izle
istu
ng
(W)
-40 -20 0
Umgebungstemperatur (°C)
Leistungs-Umgebungstemperatur-DiagrammCS 160
20 40
Art. Nr. 16000.0-00
Art. Nr. 16010.0-00
Art. Nr. 16020.0-00
178
160
147
132
119122
110
102
9385
6661
55
5044
50 W to 150W
Heating capacity / Ambient temperature diagram CSF 060
Temperature (ºC)
Heater CSF 060
Example of connection
Hea
ting
capa
city
(W)
16 17
• Small, compact design• Quite in operation• Dynamic heating up• Clip or screw fixing
Fan heater prevents formation of condensation and provides an evenly dis-tributed interior air temperature in enclosures with electric/electronic compo-nents. The heater is connected using the internal terminal connectors. The CS 028’s small size make it ideal for use in enclosures where space is at a premium.
Heating element PTC heating elementInrush current max. 12A at 230VAC, 6A at 120VACSurface temperature max. 50ºC at casing; 100ºC at upper protective grille
at 20ºC ambient temperature.Axial fan, ball bearing Air flow 13.8m3/h, free flow (service life 40,000h at 40ºC)Connection 2-pole clamp max. 2.5mm2, clamping screw torque 0.8Nm max.Casing Plastic according to UL94-0, blackMounting Clip for 35mm DIN rail, EN 60715 or screw fixing (Ø5.3mm)Fitting position VerticalWeight Approx. 0.3kgOp./storage temp. -45 to +70ºCProt. type / Prot. class IP20 / II (double insulated)Note Other voltages on request.
Technical Data:
Art. No. Operating voltage Heating capacity* Dimensions Mounting Approvals230VAC, 50/60Hz 150W 87 x 65 x 75mm Clip fixing VDE; (UL submitted)230VAC, 50/60Hz 150W 87 x 65 x 114mm Screw fixing VDE, (UL submitted)120VAC, 50/60Hz 150W 87 x 65 x 75mm Clip fixing UL submitted120VAC, 50/60Hz 150W 87 x 65 x 114mm Screw fixing UL submitted
*at 20ºC ambient temperature.
Small Semiconductor
Fan Heater - CS 028
9065
75
6590
75
32
95
3020
10
0
40
50
60
L
N
43
32
95
75
9065
75
6590
75
32
95
3020
10
0
40
50
60
L
N
43
32
95
75
150W
Heating capacity / Ambient temperature diagram CSF 060
Temperature (ºC)
FAN Heater CS 028
Clip fixing
Thermostat KTO 011(contact breaker, normally closed)
Example of connection
Screw fixing
View: back side
Hea
ting
capa
city
(W)
18 19
• Small, compact design• Quiet in operation• Dynamic heating up• Clip or screw fixing
Fan heater prevents formation of condensation and provides an evenly dis-tributed interior air temperature in enclosures with electric/electronic compo-nents. The heater is connected using the internal terminal connectors. The small size of the CSL 028 makes it ideal for use in enclosures where space is at a premium.
Compact Semiconductor
Fan Heater - CSL 028
Heating element PTC heating elementSurface temperature 250W: max 50ºC, except upper protective grille
400W: max 65ºC, except upper protective grilleat 20ºC ambient temperature
Axial fan, ball bearing Air flow 45m3/h at 230VAC, air flow 54m3/h at 120VACfree flow, service life 40,000h at 40ºC
Connection 2-pole clamp max. 2.5mm2 with strain relief, clamping torque 0.8Nm max.
Casing Plastic acc. to UL94-0, blackMounting Clip for 35mm DIN rail, EN 60715 or screw fixing (Ø5.3mm)Fitting position VerticalWeight Approx. 0.5kgOp./storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)Note Other voltages on request
Technical Data:
Art. No. Operating voltage Heating capacity* Inrush current max. Dimensions Mounting Approvals83710 230VAC, 50/60Hx 250W 9A 111x85x90mm Clip fixing VDE; (UL submitted)83711 230VAC, 50/60Hz 250W 9A 111x85x129mm Screw fixing VDE; (UL submitted)
120VAC, 50/60Hz 250W 6A 111x85x90mm Clip fixing UL submitted120VAC, 50/60Hz 250W 6A 111x85x129mm Screw fixing UL submitted
83715 230VAC, 50/60Hz 400W 15A 111x85x90mm Clip fixing VDE; (UL submitted)83716 230VAC, 50/60Hz 400W 15A 111x85x129mm Screw fixing VDE; (UL submitted)
120VAC, 50/60Hz 400W 9A 111x85x90mm Clip fixing UL submitted120VAC, 50/60Hz 400W 9A 111x85x129mm Screw fixing UL submitted
*at 20ºC ambient temperature
250W, 400W
Heating capacity / Ambient temperature diagram CSF 060
Temperature (ºC)
Hea
ting
capa
city
(W)
FAN Heater CSL 028
Clip fixing
Thermostat KTO 011(contact breaker, normally closed)
Example of connection
Screw fixing
View: back side
18 19
FAN Heater CSL 028
Clip fixing
Electrical Smart Space-Heater, General purpose
SAN-GSMLP Heater
Power consumption 200-20 WattElectrical cable 3x1 sqmmMaterial cable non-braided silicone cableStandard length approx. 1 mtr. Other lengths optionalOther lengths To be specifiedOverall dimensions 100x54x54mm (LxWxH)Weight Approx. 1400gMaterial black anodized aluminiumProtection degree IP66Voltage 110/240
Technical Data:
Description
All SMART Space-heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption.
Our SMART Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96 thermostat as a maximum temperature protection, in the system. When required in other applications, e.g. analyzers, it is normal practice to use our SMART Space-heaters in combi-nation with our FixTherm96 thermostats (range from 10°C up to 135°C).
Do not cover the fins to guarantee free convection..
High power model:GSMLP-0AHP T3 ca. 130°C Surface temperature 200-20 Watt
* these temperatures are measured at 20 °C ambient temperature.
Space-heaters for Non-Hazardous locations are designed for• Anticondensation• Freeze protection• Temperature maintenance
Features and Advantages• Self-limiting heating elements• Small dimensions• No maintenance required, no moving parts: long lifetime• Can be used for 110 / 240 VAC/DC
20 21
Explosion proof
Anti Condensation Heater - SP
Power consumption 250-25Watt or 500-50WattElectrical cable 3x1 sqmmMaterial cable Braided silicone (standard) non-braided optionalStandard length approx. 1 mtr. Other lengths optional, on requestOther lengths To be specifiedOverall dimensions 165x185x41,6mm (LxWxH)Weight Approx. 1600gMaterial black anodized aluminiumEX protection class II2G Ex d IIC T4 or T3: II2D Ex tD A21 IP66 T135ºC or T200ºCCertification KEMA 01ATEX2124X and IECEx DEK 11.0017Protection degree IP66Voltage 110/240 VAC/DCAmbient temp. range -60ºC...+90ºC
Technical Data:
Space-heaters for Hazardous locations are designed for • Freeze protection • Anti-condensation • Temperature maintenance
Features and Advantages • Self-limiting heating elements • Small dimensions • No maintenance required, no moving parts: long lifetime • Suitable for T4 and T3 classifications • Can be used for 110 / 240 VAC/DC Description
*these temperatures are measured at 20ºC ambient temperature.
All SP Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our SP Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.When required in other appications, e.g. analyzers, it is normal to use our space heaters in combination with our Fix-Therm96 termostats (range from 10°C up to 135°C).
Do not cover the fins to guarantee free convection.
Part No. Temp. class Surface temp. WattageSP-1A T3 Approx 115ºC 250-25
SP-2A T4 Approx 105ºC 250-25
SP-3A T4 Approx. 90ºC 250-25
SP-4A T4 Approx. 70ºC 250-25
High power modelSP-0AHP T3 Approx. 130ºC 500-50
20 21
Electrical Smart-Space Heater
Type GSM-*A
Power consumption 250-25Watt or 500-50WattElectrical cable 3x1 sqmmMaterial cable Non-braided silicone cableStandard length approx. 1 mtr. Other lengths optional, on requestOther lengths To be specifiedOverall dimensions 164x54x54mm (LxWxH)Weight Approx. 1400gMaterial black anodized aluminiumVoltage AC/DC 110/240Protection class IP66
Technical Data:
Space-heaters for Non-Hazardous locations, designed for • Freeze protection • Anti-condensation • Temperature maintenance
Features and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there-
fore long lifetime • Can be used for 110 / 240 VAC/DC
*these temperatures are measured at 20ºC ambient temperature.
DescriptionAll Smart Space-Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Smart Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.When required in other applications, e.g. analyzers, it is normal practice to use our Smart Space-Heaters in combina-tions with our FixTherm96 (range from 10°C up to 130°C).
Part No. Surface temp. WattageSmart GSM-1A Approx 115ºC 250-25Smart GSM-2A Approx 105ºC 250-25Smart GSM-3A Approx. 90ºC 250-25Smart GSM-4A Approx. 70ºC 250-25
High power modelSmart GSM-0AHP Approx. 130ºC 500-50
22 23
Electrical Smart-Space Ex Heater
Type SM-*A
Power consumption 250-25Watt or 500-50WattElectrical cable 3x1 sqmmMaterial cable Braided silicone (standard) Non-braided optionalStandard length approx. 1 mtr. Other lengths optional, on requestOther lengths To be specifiedOverall dimensions 164x54x54mm (LxWxH)Weight Approx. 400gMaterial black anodized aluminiumEX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°CCertification KEMA 01ATEX2124X and IECEx DEK 11.0017Voltage AC/DC 110/240 VAC/DCProtection degree IP66Ambient temp. range -60°C...+90°C
Technical Data:
Space-heaters for Hazardous locations, designed for • Freeze protection • Anti-condensation • Temperature maintenance• Small spacesFeatures and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there-
fore long lifetime • Suitable for T4 and T3 classification• Can be used for 110 to 240 VAC/DC
DescriptionAll Smart Space-Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Smart Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.In other situations, if the equipment may not exceed a maximum temperature value, our Fix-Therm96 thermostat can be added as a maximum temperature protection, in the system.When required in other applications, e.g. analyzers, it is normal practice to use our Smart Space-Heaters in combina-tions with our FixTherm96 (range from 10°C up to 135°C).
Part No. Surface temp. WattageSmart SM-1A Approx 115ºC 250-25Smart SM-2A Approx 105ºC 250-25Smart SM-3A Approx. 90ºC 250-25Smart SM-4A Approx. 70ºC 250-25
High power modelSmart SM-0AHP Approx. 130ºC 500-50
*these temperatures are measured at 20°C ambient temperature.
22 23
Electrical Direct Ex Heater
Type CS-*S
Power consumption 250-25WattElectrical cable 3x1 sqmmMaterial cable Braided silicone; optional: Non-braided optionalStandard length approx. 1 mtr. Other lengths optionalOther lengths To be specifiedOverall dimensions 85x65x28mm (LxWxH)Weight Approx. 900gMaterial stainless steel 316EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°CCertification KEMA 01ATEX2124X and IECEx DEK 11.0017Voltage AC/DC 110/240 VAC/DCProtection degree IP66Ambient temp. range -60°C...+90°C
Technical Data:
Space-heaters for Hazardous locations, designed for direct mounting onto e.g. manifolds etc. • Freeze protection • Anti-condensation • Temperature maintenanceFeatures and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there-
fore long lifetime • Suitable for T4 and T3 classification• Can be used for 110 to 240 VAC/DC
DescriptionAll Cameo Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Cameo Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
Part No. Classification Surface temp. WattageCS-1S T3 Approx 115ºC 250-25CS-2S T4 Approx 105ºC 250-25CS-3S T4 Approx. 90ºC 250-25CS-4S T4 Approx. 70ºC 250-25
*these temperatures are measured at 20°C ambient temperature.
24 25
Electrical Direct Ex Heater
Type CT-*A
Power consumption 250-25WattElectrical cable 3x1 sqmmMaterial cable Braided silicone; optional: Non-braided optionalStandard length approx. 1 mtr. Other lengths optionalOther lengths To be specifiedOverall dimensions 88x70x35mm (LxWxH)Weight Approx. 550gMaterial black anodized aluminiumEX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°CCertification KEMA 01ATEX2124X and IECEx DEK 11.0017Voltage AC/DC 110/240 VAC/DCProtection degree IP66Ambient temp. range -60°C...+90°C
Technical Data:
Direct heaters for Hazardous locations, designed for • Freeze protection • Anti-condensation • Temperature maintenanceFeatures and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there-
fore long lifetime • Suitable for T4 and T3 classification• Can be used for 110 to 240 VAC/DC
DescriptionAll Cameo Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Cameo Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
Part No. Classification Surface temp. WattageCT-1A T3 Approx 115ºC 250-25CT-2A T4 Approx 105ºC 250-25CT-3A T4 Approx. 90ºC 250-25CT-4A T4 Approx. 70ºC 250-25
*these temperatures are measured at 20°C ambient temperature.
24 25
Anti Condensation & Space Heater
Type SAN-HEF Hazardous Area
The self-regulating properties of the HEF enclosure hea-ters eliminate the requirement for a thermostat. Coupled with the compact design, this makes the HEF ideal for anti condensation, frost protection and temperature control where the enclosure is located within Zone 1 and Zone 2 Hazardous Areas.Certified to ATEX Directive 94/9/EC IECEx, they are suitable for use where the flammable atmosphere is Group IIA, IIB or IIC Gas.
Features • Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx.• Compact, low profile, stainless steel case, requires minimal space.• Self-regulating - can be used without a thermostat.• Suitable for ambient temperatures from -60° to +80°C.• Mounting of the heater can be in any orientation.• Design allows installation close to internal components and cables without fear of damage by overheating.
Typical Applications:Control / monitoring panelsInstrumentation cabinetsCondensation preventionTemperature fluctuationsFrost protection
CertificationATEX certified Ex II 2 GIECEx & ATEX certified Ex’e’ T4EN/IEC60079-0 & EN/IEC60079-7
CasingPerforated stainless steel
ElementSelf-regulating
ControlsThe HEF is self-regulating, automatically reducing its output as the ambient temperature rises if overall enclosure temperature control is required it is recommended that the HEF heater is used in conjunction with one of the Ex’d’ thermostats.
MountingThe heater may be mounted in any orientation, using appropriate securing bolts through the mounting feet.
RatingThe HEF range is available in a nominal 30, 50, 100, 200 & 500 Watt outputs, models available for 110V or 230-240V single phase supplies.
26 27
• Compact• Flat design• High air flow• Temperature safety cut-out• Clip fixing
The compact high-performance fan heater prevents formation of condensa-tion in control or switch systems and provides an evenly distributed interior air temperature in enclosures. This fan heater is available without fan (HV 031) as well as with fan (HVL 031).
Space-saving
Fan Heater HV/HVL 031 Series
HV 031 Heater without fan (fan mounting kit included)HVL 031 Heater with fanHeating element High performance cartridgeTemp. safety cut-out To protect against overheating in case of fan failureHeater body Die-cast aluminium (glass bead blasted)Connection 3-pole screw connector 2.5mm², clamping torque 0.8Nm max.Connection casing Plastic acc. to UL94 V-0, blackMounting Clip for 35mm DIN rail, EN 60715Fitting position HorizontalOp./storage temp. -45 to +70ºC Prot. type / Prot. class IP20/I (earthed)Approvals UL file E187294 (230V only: VDE)HVL 031 only:Axial fan, ball bearing Airflow see table
Service life 50,000h at 25°CConnection (axial fan) 2-pole screw connector 2.5mm2 (L2/N2)
Important! Heater may only be operated together with fan. Danger of overheating!
Technical Data:
Art. No. HV 031230VAC, 50/60Hz
Art. No. HV 031120VAC, 50/60Hz
Heating capacity Dimensions Weight (approx.)
83275 100W 80x112 22mm 0.4kg83276 150W 80x112x22mm 0.4kg83277 200W 119x151x22mm 0.5kg83278 300W 119x151x22mm 0.5kg83279 400W 119x151x22mm 0.5kg
Art. No. HVL 031230VAC, 50/60Hz
Art. No. HVL 031120VAC, 50/60Hz
Heating capacity Airflow min., free flow
Dimension Weight (Approx.)
83178 100W 35m3/h 80x112x47mm 0.6kg83179 150W 35m3/h 80x112x47mm 0.6kg83180 200W 108m3/h 119x151x47mm 0.9kg83181 300W 108m3/h 119x151x47mm 0.9kg83182 400W 108m3/h 119x151x47mm 0.9kg
100W to 400W
a.) Clipb.) Type platec.) Axial fand.) Air direction
26 27
• Compact heater• Heating capacity adjusts to ambient temperature• Adjustable temperature range• Clip fixing• Optical indicator• Temperature safety cut-out
Semiconductor fan heaters prevent the formation of condensation and ensure an even temperature in switch and control equipment. The built-in regulator is used to set the desired temperature.
Semiconductor Fan Heater - CR 027 Series
Heating element PTC resistor, temperature limitingTemp. safety cut-out To protect against overheating in case of fan failureAxial fan, ball bearing Airflow see table
service life 50,000h at 25°CConnection 2-pole clamp 2.5mm2, clamping torque 0.8Nm max.Casing Plastic, according to UL94 V-0, light greyOptical indicator Thermostat control lampMounting Clip for 35mm DIN rail, EN 60715Fitting position VerticalOp./storage position -45 to +70ºCDimensions 100 x 128 x 165mmProt. type / Prot. class IP20 / II (double insulated)Approvals UL file E204590
Technical Data:
Art. No. Operating voltage
Heating capacity* (50Hz)
Heating capacity* (60Hz)
Inrush current max.
Airflow, free flow
Setting range Temp. regulator
Weight(approx)
83285 220-240VAC, 50/60Hz 475W 550W 11.0A 35m3/h 0 to +60°C 0.9kg83286 220-240VAC, 50/60Hz 550W 650W 13.0A 45m3/h 0 to +60ºC 1.1kg83287 100-120VAC, 50/60Hz 400W 550W 14.0A 35m3/h +32 to +140°F 0.9kg83288 100-120VAC, 50/60Hz 510W 650W 15.0A 45m3/h +32 to +140ºF 1.1kg* At 20ºC (68˚F) ambient temperature.
up to 650W
Heating capacity / Ambient temperature diagram CR 027 (50Hz)
Heating capacity / Ambient temperature diagram CR 027 (60Hz)
Temperature (ºC) Temperature (ºC)
Hea
ting
capa
city
(W)
Hea
ting
capa
city
(W)
28 29
• Compact design• Double insulated• Integrated thermostat or hygrostat
The compact high performance fan heater prevents formation of condensa-tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as protection against contact. The fan heater is available with integrated thermostat or pre-set hygrostat for temperature or humidity control. The CR 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing the fan heater CR 130 is recommended.
Heating element High performance cartridgeTemp. safety cut-out to protect against overheating in case of fan failure,
automatic resetHeater body extruded aluminium profileAxial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°CConnection 2-pole clamp max. 2.5mm2, clamping screw with strain relief, torque
0.8Nm max.Casing Plastic according to UL94-0, blackMounting Screw fixing (M5)Fitting position HorizontalDimensions 168 x 145 x 100mmWeight Approx. 1.4kgOp.*/storage temp. -45 to +70ºCProt. type / Prot. class IP20 / II (double insulated)Note Other heating capacities from 200W up available on request.
*Operating temperature of heater with integrated hygrostat: 0 to +60°C
Technical Data:
Art. No. Model Operating voltage Heating capacity Setting range ApprovalsFan Heater with thermostat 230VAC, 50/60Hz 950W 0 to +60°C VDE + UL File No. E234324*Fan Heater with hygrostat 230VAC, 50/60Hz 950W 65% RH, factory-set VDE + UL File No. E234324*
Fan Heater with thermostat 120VAC, 50/60Hz 950W +32 to +140°F UL File No. E234324**according to UL499 in combination with UL508A
Compact high-performance
Fan Heater - CR 030
950W
Connection diagram
28 29
• Compact design• Double insulated• Integrated thermostat or hygrostat• Optional clip or screw fixing
The compact high performance fan heater prevents formation of condensa-tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as protection against contact. The fan heater is available with integrated thermostat or pre-set hygrostat for temperature or humidity control. The CR 130 was designed as a stationary unit for wall fixing. For fix-ing on the bottom of the enclosure the fan heater CR 030 is recommended.
Compact high-performance
Fan Heater - CR 130
Heating element High performance cartridgeTemp. safety cut-out to protect against overheating in case of fan failure,
automatic resetHeater body Extruded aluminium profileAxial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°CConnection 2-pole max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm
max.Casing Plastic according to UL94 V-0, blackMounting Clip for 35mm DIN rail, EN 60715 or screw fixing (M6)Fitting position HorizontalDimensions 182 x 160 x 99mmWeight Approx. 1.5kgOp.*/storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)Note Other heating capacities from 200W up available on request.
*Operating temperature of heater with integrated hygrostat: 0 to +60°C
Technical Data:
Art. No. Model Operating voltage Heating capacity Setting range Approvals
Fan Heater with thermostat 230VAC, 50/60Hz 950W 0 to +60°C VDE + UL File No. E234324*Fan Heater with hygrostat 230VAC, 50/60Hz 950W 65% RH, factory-set VDE + UL File No. E234324*
Fan Heater with thermostat 120VAC, 50/60Hz 950W +32 to +140°F UL File No. E234324*
*according to UL499 in combination with UL508A
950W
Connection diagram
30 31
Art. No. Model Operating voltage Heating capacity1) Inrush current max. Setting range Approvals83268 Fan Heater with thermostat 230VAC, 50/60Hz 1,200W 13A 0 to +60°C VDE + UL File No. E2343242)
83269 Fan Heater without thermostat 230VAC, 50/60Hz 1,200W 13A - VDE + UL File No. E2343242)
Fan Heater with thermostat 120VAC, 50/60Hz 1,200W 16A +32 to +140°C UL File No. E2343242)
Fan Heater without thermostat 120VAC, 50/60Hz 1,200W 16A - UL File No. E2343242)
1)at 20°C ambient temperature; 2)according to UL499 in combination with UL508A
• Compact design• High heating performance• Double insulated• Integrated thermostat (optional)
The compact high performance fan heater prevents formation of condensa-tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as pretection against contact. The fan heater is available with optional integrated thermostat for temperature control. The CS 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing the fan heater CS 130 is recommended.
Heating element PTC resistor - temperature limitingTemp. safety cut-out to protect against overheating in case of fan failureAxial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°CConnection 2-pole clamp max. 2.5mm2, clamping screw with strain relief, torque
0.8Nm max.Casing Plastic according to UL94-0, blackMounting Screw fixing (M5)Fitting position HorizontalDimensions 168 x 145 x 120mmWeight Approx. 1.2kgOp./storage temp. -45 to +70ºCProt. type / Prot. class IP20 / II (double insulated)
Technical Data:
Compact high-performance semiconductor
Fan Heater - CS 030
30
1,200W
Connection diagram
Heating capacity / Ambient temperature diagram CS 030
Temperature (ºC)
Hea
ting
capa
city
(W)
30 31
• Compact design• High heating performance• Double insulated• Integrated thermostat (optional)• Optional clip or screw fixing
The compact high performance fan heater prevents formation of condensa-tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as protection against contact. The fan heater is available with optional integrated thermostat for temperature control. The CS 130 was designed as a stationary unit for wall fixing. For fixing on the bottom of the enclosure the fan heater CS 030 is recommended.
Compact high-performance semiconductor
Fan Heater - CS 130
Heating element PTC resistor - temperature limitingTemp. safety cut-out to protect against overheating in case of fan failureAxial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°CConnection 2-pole max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm
max.Casing Plastic according to UL94 V-0, blackMounting Clip for 35mm DIN rail, EN 60715 or screw fixing (M6)Fitting position HorizontalDimensions 182 x 160 x 120mmWeight Approx. 1.3kgOp.*/storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)
Technical Data:
Art. No. Model Operating voltage Heating capacity1) Inrush current max. Setting range Approvals83266 Fan Heater with thermostat 230VAC, 50/60Hz 1,200W 13A 0 to +60°C VDE + UL File No. E2343242)
83267 Fan Heater without thermostat 230VAC, 50/60Hz 1,200W 13A - VDE + UL File No. E2343242)
Fan Heater with thermostat 120VAC, 50/60Hz 1,200W 16A +32 to +140°F UL File No. E2343242)
Fan Heater without thermostat 120VAC, 50/60Hz 1,200W 16A - UL File No. E2343242)
1)at 20°C ambient temperature; 2)according to UL499 in combination with UL508A
1,200W
Heating capacity / Ambient temperature diagram CS 130
Temperature (ºC)
Hea
ting
capa
city
(W)
Connection diagram
32 33
• Very low noise• Minimal depth in enclosure• Functional design• Time-saving installation• Weather proof and UV resistant
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the elec-tronic components from overheating. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.
Special features:• The self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet.• Functional design of the intake and exit fan hoods very effectively prevents direct intrusion of falling
water and dust. The advantage is that the filter mat does not get so quickly contaminated with dirt and thus does not need to be exchanged so often.
• The air channelling makes the filter fan particularly quiet in operation.• Functional and modern design enables time-saving assembly and maintenance.• All filter fan models are also available with integrated airflow monitor.• EMC versions and other voltages on request.• The direction of air can easily be switched by reversing the axial fan (sizes 1 to 3).
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH)fan body aluminium, rotor plastic
Connection 2 wires with pressure clamps 2.5mm2, length 100mmCasing (filter fan and exit filter) Plastic according to UL94-V-0, light greyHood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)Mounting frame with double-sided industrial adhesive band for fixing to the outside of
enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out.
Filter mat G4 acc. to DIN EN 779, filtering degree 94%Filter material Synthetic fibre with progressive construction, temperature resistant
to 100°C, self-extinguishing class F1; moisture resistant to 100% RH, reusable - cleaning by washing or vacuuming
Op./storage temp. -45 to +70ºCProt. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, bt reduces the air volume.
Technical Data:
Art. No. Operating voltage
Air volume, free flow
Air volume with
exit filter
Current consump-
tion
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out
Weight (approx.)
Approvals
230VAC, 50Hz
21m3/h 16m3/h 80mA 13W 31dB (A) 45mm 97 x 97mm +0.4
0.6kg VDE + UL File No. E234324
230VAC, 50Hz
55m3/h 42m3/h 100mA 15W 40dB (A) 58mm 125 x 125mm +0.4
1.0kg VDE + UL File No. E234324
230VAC, 50Hz
102m3/h 68m3/h 100mA 15W 39dB (A) 86mm 176 x 176mm +0.4
1.3kg VDE + UL File No. E234324
120VAC, 60Hz
24m3/h 18m3/h 160mA 13W 31dB (A) 45mm 97 x 97mm +0.4
0.6kg UL File No. E234324
120VAC, 60Hz
63m3/h 48m3/h 180mA 15W 40dB (A) 58mm 125 x 125mm +0.4
1.0kg UL File No. E234324
120VAC, 60Hz
117m3/h 78m3/h 180mA 15W 39dB (A) 86mm 176 x 176mm +0.4
1.3kg UL File No. E234324
21m3/h to 102m3/h
Filter Fan FF 018 Series
32 33
Time-saving assembly and maintenanceSAN’s filter fans are easily installed by one person from outside the cabinet.
1. Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, fillings and grease. A template for the enclosure cut-out is included in the delivery of the filter fan.
2. Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays perma-nently in the cabinet. (For size 176mm and up we recommend additional screw fixing.)
3. Electrically connect the axial fan using the clip connectors. Push the unit into the mounting frame. Fix using screws.
4. Insert the filter mat in the hood. Clip on. Finished.
Changing the filter mat or fan is quickly done by one person. To change the filter mat simply remove the filter hood, insert the new mat and snap the hood back again. No tools required. Maintenance of the fan can easily be done without removing the mounting frame (2).
Filter Fan FF 018 Series
Art. No. Operating voltage
Air volume, free flow
Air volume with exit filter
Current con-sumption
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out Weight (approx.)
230VAC, 50Hz 21m3/h 16m3/h 80mA 13W 31dB (A) 45mm 97 x 97mm +0.4 0.6kg230VAC, 50Hz 55m3/h 42m3/h 100mA 15W 40dB (A) 58mm 125 x 125mm +0.4 1.0kg230VAC, 50Hz 102m3/h 68m3/h 100mA 15W 39dB (A) 86mm 176 x 176mm +0.4 1.3kg120VAC, 60Hz 24m3/h 18m3/h 160mA 13W 31dB (A) 45mm 97 x 97mm +0.4 0.6kg120VAC, 60Hz 63m3/h 48m3/h 180mA 15W 40dB (A) 58mm 125 x 125mm +0.4 1.0kg120VAC, 60Hz 117m3/h 78m3/h 180mA 15W 39dB (A) 86mm 176 x 176mm +0.4 1.3kg
For techinal data see Airflow Monitor LC 013/LCF 013 (Normally Closed, Normally Open)
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type16mm 97x97mm +0.4 0.3kg G4 acc. to DIN EN 779, filtering degree 94% IP54*16mm 125x125mm +0.4 0.4kg G4 acc. to DIN EN 779, filtering degree 94% IP54*16mm 176x176mm +0.4 0.6kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Filter mat 89 x 89mm 118 x 118mm 168 x 168mmG4 (1 packing unit = 3 pcs) Art. no. Art. no. Art. no.F5 (1 packing unit = 3 pcs) Art. no. Art. no. Art. no.
Dimensional DrawingSize 1 Size 2 Size 3
Drilling template for mounting frame
Exit filter EF 118 Series
Filter Mats FM 086 / FFM 086
Filter Fan with Airflow Monitor FFLC 218 (Normally Closed)Airflow monitor integrated in protective grille of filter fan, e.g. Art. no.
Installation sketch
34 35
• Low maintenance• High through-flow air volume• Functional design• Time-saving installation• Weather proof and UV resistant
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the elec-tronic components from overheating. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH)fan body aluminium, rotor metal
Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max.Casing (filter fan and exit filter) Plastic according to UL94-V-0, light greyHood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)Mounting frame with double-sided industrial adhesive band for fixing to the outside of
enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out.
Filter mat G4 acc. to DIN EN 779, filtering degree 94%Filter material Synthetic fibre with progressive construction, temperature resistant to
100°C, self-extinguishing class F1; moisture resistant to 100% RH, reusable - cleaning by washing or vacuuming
Op./storage temp. -45 to +70ºCProt. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Technical Data:
Art. No. Operating voltage
Air volume, free flow
Air volume with exit filter
Current con-sumption
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out Weight (approx.)
230VAC, 50Hz 200m3/h 125m3/h 320mA 45W 52dB (A) 95mm 176x176mm +0.4 1.7kg120VAC, 60Hz 230m3/h 143m3/h 470mA 39W 52dB (A) 95mm 176x176mm +0.4 1.7kg
200m3/h
Filter Fan FF 018 Series
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type16mm 176x176mm +0.4 0.6kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Filter mat 168x168mmG4 (1 packing unit = 3 pcs) Art. no.F5 (1 packing unit = 3 pcs) Art. no.
Exit filter EF 118 Series
Filter Fan FF 018 Series
Filter Mats FM 086 / FFM 086
Filter Fan with Airflow Monitor FFLC 218 (Normally Closed)
Art. No. Operating voltage
Air volume, free flow
Air volume with
exit filter
Current consump-
tion
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out
Weight (approx.)
Approvals
230VAC, 50Hz
200m3/h 125m3/h 320mA 45W 52dB (A) 95mm 176x176mm +0.4
1.7kg UL File No. E234324
120VAC, 60Hz
230m3/h 143m3/h 470mA 39W 52dB (A) 95mm 176x176mm +0.4
1.7kg UL File No. E234324
Filter Fan
Drilling template for mounting frame
Airflow monitor integrated in protective grille of filter fan, e.g. Art. no.
Exit filterView from rear
34 35
• Very low noise• Minimal depth in enclosure• High through-flow air volume• Uniform air circulation• High reliability• Weather proof and UV resistant
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the elec-tronic components from overheating. Four integrated axial fans provide a particularly high and uniform air circulation thus contributing to higher reli-ability. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH)fan body aluminium, rotor metal
Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max.Casing (filter fan and exit filter) Plastic according to UL94-V-0, light greyHood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo-
sure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out.
Filter mat G4 acc. to DIN EN 779, filtering degree 94%Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; mooisture resistant to 100% RH, reusable - cleaning by washing or vacuuming
Op./storage temp. -45 to +70ºCProt. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Technical Data:
300m3/h
Filter Fan FF 018 Series
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type22mm 250x250mm +0.4 1.0kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Filter mat 247x247mmG4 (1 packing unit = 3 pcs) Art. no.F5 (1 packing unit = 3 pcs) Art. no.
Exit filter EF 118 Series
Filter Fan FF 018 Series
Filter Mats FM 086 / FFM 086
Art. No. Operating voltage
Air volume, free flow
Air volume with
exit filter
Current consump-
tion
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out
Weight (approx.)
Approvals
230VAC, 50Hz
300m3/h 230m3/h 400mA 60W 53dB (A) 65mm 250x250mm +0.4
3.3kg UL File No. E234324
120VAC, 60Hz
345m3/h 264m3/h 700mA 60W 53dB (A) 65mm 250x250mm +0.4
3.3kg UL File No. E234324
View from rear
Exit filter
4x Axial fan
Drilling template for mounting frame
36 37
• High through-flow air volume• Functional design• Time-saving installation• Weather proof and UV resistant
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pocket and protects the electron-ic components from overheating. The high-performance axial fan provides high air circulation. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH)fan body aluminium, rotor metal
Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max.Casing (filter fan and exit filter) Plastic according to UL94-V-0, light greyHood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo-
sure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out.
Filter mat G4 acc. to DIN EN 779, filtering degree 94%Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; moisture resistant to 100% RH, reusable - clean-ing by washing or vacuuming
Op./storage temp. -45 to +70ºCProt. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Technical Data:
Art. No. Operating voltage
Air volume, free flow
Air volume with exit filter
Current con-sumption
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out Weight (approx.)
230VAC, 50Hz 550m3/h 300m3/h 300mA 64W 65dB (A) 107mm 250x250mm +0.4 2.7kg120VAC, 60Hz 632m3/h 345m3/h 780mA 85W 65dB (A) 107mm 250x250mm +0.4 2.7kg
550m3/h
Filter Fan FF 018 Series
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type22mm 250x250mm +0.4 1.0kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Filter mat 247x247mmG4 (1 packing unit = 3 pcs) Art. no.F5 (1 packing unit = 3 pcs) Art. no.
Exit filter EF 118 Series
Filter Fan FF 018 Series
Filter Mats FM 086 / FFM 086
Filter Fan with Airflow Monitor FFLC 218 (Normally Closed)
Art. No. Operating voltage
Air volume, free flow
Air volume with
exit filter
Current consump-
tion
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out
Weight (approx.)
Approvals
230VAC, 50Hz
550m3/h 300m3/h 300mA 64W 65dB (A) 107mm 250x250mm +0.4
2.7kg UL File No. E234324
120VAC, 60Hz
632m3/h 345m3/h 780mA 85W 65dB (A) 107mm 250x250mm +0.4
2.7kg UL File No. E234324
Filter Fan
Drilling template for mounting frame
Airflow monitor integrated in protective grille of filter fan, e.g. Art. no.
Exit filterView from rear
36 37
• Filter changeable from outside• Safe, lockable• Impact resistant• Weather proof and UV resistant
The outdoor filter fan can be used in outdoor enclosures where warm air has to be dissipated on account of increased thermic development. To clean and exchange the filter mat, it is only necessary to open the lockable door of the outdoor hood. A protection type of IP55 is achieved due to the special de-sign of the hood and the use of fine filter mats. The plastic casing is impact resistant, highly weather proof and resistant to UV light.
Outdoor
Filter Fan - FF 018 Series
Axial fan, ball bearing Service life min. 50,000h at 25°C (65% RH)fan body aluminium, rotor plastic
Connection 2 wires with pressure clamps 2.5mm2, length 100mmCasing (filter fan and exit filter) Casing material high impact plastic ASA, light grey burning behaviour ac-
cording to UL94 H-B; high resistance to weather and UVMounting frame with double-sided industrial adhesive band for fixing to the outside of enclo-
sure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out.
Filter mat F5 acc. to DIN EN 779, filtering degree 98%Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; moisture resistant to 100% RHOp./storage temp. -45 to +70ºCProt. type / Prot. class IP55 / I (earthed)Approvals UL File No. E234324
The hood is fixed permanently to the enclosure from the inside using screws. Filter mats can be easily changed from outside the enclosure through the lockable door in the hood.
Technical Data:
Art. No. Operating voltage Air volume, free flow
Current con-sumption
Power consump-
tion
Average noise level (DIN EN ISO 4871)
Depth in enclosure
Enclosure cut-out Weight (approx.)
230VAC, 50Hz 20m3/h 100mA 15W 40dB (A) 62mm 125x125mm +0.4 1.2kg120VAC, 60Hz 23m3/h 180mA 15W 40dB (A) 62mm 125x125mm +0.4 1.2kg
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type16mm 125x125mm +0.4 0.6kg F5 acc. to DIN EN 779, filtering degree 98% IP55
Filter mat 122x122mmF5 (1 packing unit = 3 pcs) Art. no.
Exit filter EF 118 Series
Filter Mats FFM 086
Filter Fan with Airflow Monitor FFLC 218 (Normally Closed)
Outdoor Filter Fan
Drilling template for mounting frame
Outdoor Exit filterView from rear
38 39
• Very low noise• Minimal depth in enclosure• High through-flow air volume• Uniform air circulation• High reliability• Time-saving installation
Roof filter fans and roof exit filters find use in enclosures, from which warm air has to be diverted due to increased heat development. The ready-to-connect and low-noise roof filter fan, which houses four axial fans, is used to expel warm air from within the enclosure which has been generated by the stray power of the components. The roof exit filter provides passive ventilation.
Low noise
Roof Filter Fan - RFF 018 Series
350m3/h
Axial fans, ball bearing Service life 50,000h at 25°C (65% RH)fan body aluminium, rotor plastic
Connection 3-pole clamp for 2.5mm2
Casing Plastic according to UL94-V-0 / lacquered steel sheet, light greyFilter mat G3 acc. to DIN EN 779, filtering degree 85%Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; moisture resistant to 100% RH, reusable - clean-ing by washing or vacuuming
Op./storage temp. -45 to +70ºCProt. type IP43 (with filter mat G3 / IP33 (without filter mat)Prot. class I (earthed)Approvals UL FIle No. E234324
Important note: For reasons of pressure compensation the roof filter fan must always be operated in combi-nation with another filter fan (e.g. Art. No. ) or a passive intake filter (e.g. Art. No.).
Technical Data:
Art. No. Operating voltage
Air volume, free flow
Air volume with exit filter
Current con-sumption
Power consump-
tion
Average noise level (DIN EN
ISO 4871)
Depth in enclosure
Enclosure cut-out Weight (approx.)
230VAC, 50Hz 350m3/h (w/filter mat G3)
500m3/h (w/o filter mat)
400mA 60W 55dB (A) 44mm 250x250mm +0.4 4.4kg
120VAC, 60Hz 402m3/h (w/filter mat G3)
575m3/h (w/o filter mat)
700mA 60W 55db (A) 44mm 250x250mm +0.4 4.4kg
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection typenone 250x250mm +0.4 2.0kg G3 acc. to DIN EN 779, filtering degree 85% IP43 (w/filter mat)
Filter mat 282x282mmG3 (1 packing unit = 3 pcs) Art. no.
Roof Exit filter REF 118 Series
Filter Mats FM 086
Roof Filter Fan RFF 018 Series
Roof Filter Fan RFF 018
Enclosure cut-out
Hol
e ce
nter
sRoof Exit filterREF 118
View from below
38 39
• High air output• Long service life• Ball bearing fans• Ready for connection• Optical function indicator
Compact high performance fan tray for enforced circulation of air in switch and server enclosures and for concerted cooling of 19” component groups. Natural convection is improved and the formation of localised hot pockets is avoided. Also available with integrated thermostat (see photo).
High-performance
19” Fan Tray - LE 019 Series
Axial fans, ball bearing Service life 50,000h at 25°C (65% RH) fan body aluminium, rotor plastic
Material Front panel aluminium, bright anodised casing steel sheet, electrogalvanized
Optical indicator Integrated in front panelConnection Appliance power inlet on rear of casing, plug includedFitting position Horizontal (direction of air upwards)Op./storage temp. -45 to +70ºCProt. type / Prot. class IP20 / I (earthed)Approvals UL FIle No. E234324
Note:We recommend using the fan tray in combination with our dual thermostat (ZR 011) for regulating temperature in electronic enclosures and for protection against overheating due to possible fan failure. The dual ther-mostat regulates the operation of the fan tray and when connected to a signal device also triggers an early warning if the enclosure interior temperature rises above a set limit.
When using a fan tray with integrated thermostat, the use of an additional thermostat (KTS 011) provides the extra safety of activating a signal device.
Technical Data:
Art. No. Model No. of fans
Operating voltage
Air flow, free flow
Power consumption
Average noise level (DIN EN
ISO 4871)
Speed (rpm-1) Impact pressure
Weight (approx.)
without thermostat 3 230VAC, 50Hz 486m3/h 45W 55dB (A) 2600 min-1 (50Hz) 74Pa 3.0kgwith thermostat 0 to +60°C 3 230VAC, 50Hz 486m3/h 45W 55db (A) 2600 min-1 (50Hz) 74Pa 3.4kg
without thermostat 6 230VAC, 50Hz 972m3/h 90W 57dB (A) 2600 min-1 (50Hz) 74Pa 5.3kgwith thermostat 0 to +60°C 6 230VAC, 50Hz 972m3/h 90W 57dB (A) 2600 min-1 (50Hz) 74Pa 5.7kg
without thermostat 9 230VAC, 50Hz 1458m3/h 135W 58dB (A) 2600 min-1 (50Hz) 74Pa 7.8kgwith thermostat 0 to +60°C 9 230VAC, 50Hz 1458m3/h 135W 58dB (A) 2600 min-1 (50Hz) 74Pa 7.9kg
without thermostat 3 120VAC, 60Hz 576m3/h 45W 55dB (A) 2900 min-1 (60Hz) 88Pa 3.0kgwith thermostat 0 to +60°C 3 120VAC, 60Hz 576m3/h 45W 55dB (A) 2900 min-1 (60Hz) 88Pa 3.4kg
without thermostat 6 120VAC, 60Hz 1152m3/h 90W 57dB (A) 2900 min-1 (60Hz) 88Pa 5.3kgwith thermostat 0 to +60°C 6 120VAC, 60Hz 1152m3/h 90W 57dB (A) 2900 min-1 (60Hz) 88Pa 5.7kg
witout thermostat 9 120VAC, 60Hz 1728m3/h 135W 58dB (A) 2900 min-1 (60Hz) 88Pa 7.8kgwith thermostat 0 to +60°C 9 120VAC, 60Hz 1728m3/h 135W 58dB (A) 2900 min-1 (60Hz) 88Pa 7.9kg
40 41
• High DC switching capacity• Variety of applications• Compact design• Simple connection• Cliip fixing
Switch module for switching DC appliances with high switching capacity. A separate conventional switch contact is used as controller (e.g. temperature regulator, humidity regulator). The switch module is available in 24VDC and 48VDC versions.
Switch Module SM 010
24VDC + 48VDC
Contact type Contact maker, normally open (Relay/MOSFET)Contact resistance <10mΩService life >100,000 cyclesEMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 6-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 67x50x46mmWeight Approx. 90gFitting position VariableOp./storage temp. -45 to +70°CProtection type IP20Approvals VDE submitted
Technical Data:
Art. No. Operating voltage Max. Switching capacity24VDC (20-28VDC) 28VDC 16A48VDC (38-56VDC) 56VDC 16A
Load e.g. heater, cooling device with temperature cut-out
Switch Module, SM 010
Control contact,e.g. temperature,
humidity or pressure regulator
Load, e.g. heater, cooling device without temperature cut-out
Switch Module, SM 010
Control contact, e.g. temperature,
humidity or pressure regulator
e.g. Temperature
regulator
e.g. Heater
Fan
Power supply
40 41
• Large setting range• Small size• Simple to mount• High switching performance
KTO 011: Thermostat (normally closed), contact breaker for regulating heat-ers.KTS 011: Thermostat (normally open), contact maker for regulating of filter fans and heat exchangers or for switching signal devices when temperature limit has been exceeded.
Small, compact
Thermostat - KTO/KTS 011
Technical Data:Switch temperature difference 7K (±4K tolerance)Sensor element Thermostatic bimetalContact type Snap-action contactContact resistance <10mΩService life >100,000 cyclesMax. switching capacity 250VAC, 10 (2) A
120VAC, 15 (2) ADC 30W
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 2-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715 (or for exit filter EF 118 Series)Casing Plastic according to UL94 V-0, light greyDimensions 60x33x43mmWeight Approx. 40gFitting position VariableOp/storage temp. -45 to +80°CProtection type IP20
Setting range Art. No. Contact Breaker (NC) Art. No. Contact Maker (NO) Approvals0 to +60°C VDE
-10 to +50°C VDE+20 to +80°C VDE+32 to +140°F UL File No. E164102+14 to +122°F UL File No. E164102
0 to +60°C UL File No. E164102
Thermostat KTO 011 (NC)
Thermostat KTO 011 (NC)
Heater e.g. Fan e.g. Signal device
Connection diagramsExample of connection
Heater
Filter fan, Cooling equipment, Signal device
Thermostat KTS 011 (NO)
Thermostat KTS 011 (NO)
Thermostat KTS 011 (NO)
42 43
• Small size• Default temperature settings• Easy to install• High switching tolerance
Tamperproof (Pre-set) Thermostat FTO 011Contact breaker / NC (red casing) for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. The contact opens when temperature is rising.Tamperproof (Pre-set) Thermostat FTS 011Contact maker / NO (blue casing) for regulating filter fans, heat exchangers, cooling devices or for switching signal devices when temperature limit has been exceeded. The contact closes when temperature is rising.
Tamperproof (Pre-set)
Thermostats - FTO/FTS 011
Technical Data:
Art. No. Contact Switch-off temperature Switch-on temperature Contact breaker (NC) +15°C (±5K tolerance) +5°C (±5K tolerance) Contact breaker (NC) +25°C (±5K tolerance) +15°C (±5K tolerance) Switch-on temperature Switch-off temperature Contact maker (NO) +50°C (±6K tolerance) +40°C (±7K tolerance) Contact maker (NO) +60°C (±6K tolerance) +50°C (±7K tolerance) Contact maker (NO) +35°C (±6K tolerance) +25°C (±7K tolerance)
Thermostat FTO 011
Heater Filter fan Signal device
Example of connection
Thermostat FTS 011
Thermostat FTS 011
Sensor element Thermostatic bimetalContact type Snap-action contactContact resistance <20mΩService life >100,000 cyclesMax. switching capacity 250VAC, 5 (1.6) A
120VAC, 10 (2) ADC 30W
Max. inrush current AC 10AEMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 2-pole terminal for 2.5mm2, torque 0.8Nm max.Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 47x33x33mmWeight Approx. 30gFitting position VariableOp/storage temp. -20 to +80°C / -45 to +80°CProtection type IP20Approvals VDE + UL File No. E164102
42 43
• NO and NC in one casing• Separate adjustable temperatures• High switching capacity• Terminals easily accessible• Clip fixing
Two thermostats in one casing:Thermostat (contact breaker, normally closed) for regulating heaters.Thermostat (contact maker, normally open) for regulating filter fans and heat exchangers or switching signal devices when temperature limit has been exceeded.
Heaters and cooling equipment can be switched indepen-dently from each other with a temperature offset as op-posed to the usual change-over contacts.
Dual
Thermostat - ZR 011
Technical Data:
Thermostat ZR 011 (NC/NO)
Heater
Connection diagram
Filter fan, Cooling equipment, Signal device
Art. No. Setting Range Setting Rangecontact breaker, normally closed 0 to +60°C Contact maker, normally open 0 to +60°Ccontact breaker, normally closed +32 to +140°F Contact maker, normally open +32 to +140°Fcontact breaker, normally closed -10 to +50°C Contact maker, normally open +20 to +80°Ccontact breaker, normally closed +14 to +122°F Contact maker, normally open +68 to +176°FContact maker, normally open 0 to +60°C Contact maker, normally open 0 to +60°CContact maker, normally open +32 to +140°F Contact maker, normally open +32 to +140°F
Switch temperature difference 7K (±4K tolerance)Sensor element Thermostatic bimetalContact type Snap-action contactContact resistance <10mΩService life >100,000 cyclesMax. switching capacity 250VAC, 10 (2) A
120VAC, 15 (2) ADC 30W
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 4-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 67x50x46mmWeight Approx. 90gFitting position VariableOp/storage temp. -45 to +80°CProtection type IP20Approvals UL File No. E164102
44 45
Art. No. Contact breaker (NC) Contact maker (NO)Switch-off temperature Switch-on temperature Switch-on temperature Switch-off temperature
+15°C (±5K tolerance) +5°C (±5K tolerance) +50°C (±6K tolerance) +40°C (±7K tolerance)+25°C (±5K tolerance) +15°C (±5K tolerance) +60°C (±6K tolerance) +50°C (±7K tolerance)+15°C (±5K tolerance) +5°C (±5K tolerance) +35°C (±6K tolerance) +25°C (±7K tolerance)+25°C (±5K tolerance) +15°C (±5K tolerance) +50°C (±6K tolerance) +40°C (±7K tolerance)
Art. No. Contact maker (NO) Contact maker (NO)Switch-on temperature Switch-off temperature Switch-on temperature Switch-off temperature
+50°C (±6K tolerance) 40°C (±7K tolerance) +60°C (±6K tolerance) +50°C (±7K tolerance)
• NO and NC in one casing• Default temperature settings• High switching accuracy• Clip fixing
Two thermostats in one casing:Tamperproof (Pre-set) Thermostat/Contact breaker (NC)for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. The contact opens when temperature is rising.Tamperproof (Pre-set) Thermostat/Contact maker (NO)for regulating filter fans, heat exchangers or for switching signal devices when temperature limit has been exceeded. The contact closes when temperature is rising.
Heaters and cooling equipment can be switched independently from each other with a temperature offset as opposed to the usual change-over contacts.
Tamperproof (Pre-set)
Dual-Thermostat - FTD 011
Technical Data:
Thermostat FTD 011
Heater Filter fan
Example of connection
Sensor element Thermostatic bimetalContact type Snap-action contactContact resistance <20mΩService life >100,000 cyclesMax. switching capacity 250VAC, 5 (1.6) A
120VAC, 10 (2) ADC 30W
Max. inrush current AC 10AEMC ac. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 4-pole terminal for 12.5mm2, torque 0.8Nm max.Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 47x63x33mmWeight Approx. 40gFitting position VariableOp/storage temp. -20 to +80°C / -45 to +80°CProtection type IP20Approvals VDE + UL File No. E164102
44 45
• Adjustable temperature• High switching capacity• Small hysteresis• Terminals easily accessible• Clip fixing• Change-over contact
The mechanical thermostat is used for controlling heating and cooling equip-ment, filter fans or signal devices. The thermostat registers the surrounding air and can switch both inductive and resistive loads via snap-action contact.
Mechanical
Thermostat - FZK 011
Technical Data:Switch temperature difference 4K (±1.5K tolerance)*Sensor element Thermostatic bimetalContact type Change-over snap-action contactContact resistance <10mΩService life >100,000 cyclesMax. switching capacity, NC 250VAC, 10 (4) A
120VAC, 10 (4) ADC 30W
Max. switching capacity, NO 250VAC, 5 (2) A120VAC, 5 (2) ADC 30W
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 4-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 67x50x38mmWeight Approx. 0.1kgFitting position VariableOp/storage temp. -20 to +80°C / -45 to +80°CProtection type IP20Approvals UL File No. E164102
*Connecting terminal “N” (RF heating resistor) causes the thermal feedback to work and so reduces the switch temperature difference to approx. 0.5K.
Enclosure heater
Heater Thermostat FZK 011e.g. Filter fanfor cooling Thermostat FZK 011 Thermostat FZK 011e.g. Signal device
Connection diagram
Examples of connection
Filter fan, Cooling equipment, Signal device
Art. No. Operating voltage Setting range230VAC +5 to +60°C230VAC +40 to +140°F230VAC -20 to +30°C120VAC +40 to +140°F120VAC +5 to +60°C
46 47
• High DC breaking capacity• Low hysteresis• Adjustable temperature• Change-over contact• Clip fixing
Electronic thermostat for regulating high performance DC 24V equipment. Heating or cooling appliances as well as signal devices can be switched via the potential free change-over contact. In comparison to mechanical thermo-stats, the ET 011 has a low hysteresis making the switchng point and setting accuracy more precise.
Electronic
Thermostat - ET 011
Technical Data:Switch temperature difference Approx. 3KSensor element PTCContact type Change-overContact resistance <10mΩService life >100,000 cyclesMax. switching capacity 28VDC, 16AEMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 5-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 67x50x46mmWeight Approx. 80gFitting position VerticalOp/storage temp. 0 to +60°C / -45 to +80°CProtection type IP20Approvals -
HeaterThermostat ET 011e.g. Filter fanfor coolingThermostat ET 011 Thermostat ET 011 e.g. Signal device
Connection diagram
Examples of connection
Art. No. Operating voltage Setting range24VDC (20-28VDC) 0 to +60°C
(24VDC)
46 47
Ex FixTherm96 Thermostat
Technical Data:Housing Anodized aluminium or stainless steelCurrent / voltage 6A / 240 VACCable 3x 0,75 sqmmMaterial cable silicone braided cable, optional: non-braided cableStandard length Approx. 1 mtrOther lengths On requestOverall dimensions o.d. 30mm x 49mm lengthWeight Approx. 160gSwitch SPSTSet-point tolerance +/-3ºCHysteresis Approx. 2ºCMounting bracket avaliable (B)Ambient temp. range -50ºC...+90ºCEX protection class II 2G Ex d IIC T6 or T4
II 2D Ex tD A21 IP66TT 85ºC orT 135ºC
Certification KEMA 01ATEX2125X and IECEx DEK 11.0017
The Ex FixTherm96-Thermostats are often used as maximum thermo-stat in instrumentation cabinets with • Prevention of overheating • Temperature controlling
Features and Advantages • Setpoints up to 135°C • Accurate set-point (± 3°C) • Small hysteresis • Anodized Aluminium housing ( Stainless steel housing available) • Armoured electrical cable standard • Suitable for T6 and T4 classification • Can be used for 6A / 240 VAC/DC
DescriptionThe housing is made from anodized Aluminium or Stainless Steel type 316 (on request).
When required in other applications, e.g. analyzers, it is normal practice to use our Space-heaters in combination with these Fix-Therm96 thermostats (range from 10°C up to 135°C). The FixTherm96 can also be used for cooling purpo-ses e.g. FixTherm TH-10/5F.
RangeAluminium: TH-10/5 – going up with 5°C setpoints e.g. 10/5“ 15/10“ 20/15 etc. up to 135°C maximum.
Stainless Steel bodies: identical range.
48 49
Electrical Thermostat
Ex FixTherm96 General PurposeSAN-GTH*/*
Technical Data:Housing Anodized aluminiumCurrent / voltage 6A / 240 VACCable 3x 0,75 sqmmMaterial cable Non-braided silicone cableStandard length Approx. 1 mtr, other lengths optionalOverall dimensions 30mm x 58mm (diameter xH)Weight Approx. 160gSwitch SPSTSet-point tolerance +/-3ºCHysteresis Approx. 2ºCMounting bracket avaliable (B)protection IP66
For Non-Hazardous areas the General Purpose FixTherm96 thermostats are very suitable. Often used as maximum ther-mostat in instrumentation cabinets with space heating, to protect the equipment from overheating. Or as a minimum thermostat with space heating to protect from freezing.
In short, temperature maintenance:• Prevention of overheating• Freeze protection• Anticondensation
Features and Advantages
• Setpoints from 10°C up to 130°C• Accurate set-point - (N.C. contact)• Small hysteresis• Anodized aluminium housing (Stainless steel housing available)• Inside grounding• Can be used for 110 / 240 VAC/DC
Description
The housing is made from anodized aluminium. When required in other applications, e.g. analyzers, it is normal prac-tice to use our Space-heaters in combination with our Fix-Therm96 thermostats (range from 10°C up to 130°C). The FixTherm96 can also be used for cooling purposes e.g. FixTherm96 TH-10/5F (N.O. contact).
Range
GTH-10/5 - going up with 5°C each time e.g. 10/5 - 15/10 - 20-15 etc. up to 130°C maximum.
48 49
• Adjustable relative humidity• Change-over contact• High switching capacity• Easily accessible terminals• Clip fixing
The electromechanical hygrostat MFR 012 is designed to control enclosure heaters so that the dew point is raised when a critical relative humidity of 65% is exceeded. In this way condensation and corrosion is effectively pre-vented.
Mechanical
Hygrostat - MFR 012
Technical Data:Switch difference* 4% RH (±3% tolerance)Permissible air velocity 15m/secContact type Change-over contactContact resistance <10mΩService life >100,000 cyclesMin. switching capacity 20V AC/DC, 100mAMax. switching capacity 250VAC, 5 (1) A
DC 20WEMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Connection 3-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 67x50x38mmWeight Approx. 60gFitting position VariableOp/storage temp. 0 to +60°C / -20 to +80°CProtection type IP20Approvals UL File No. E164102
*at 50% RH.
Enclosure heaterHeater Filter FanHygrostatMFR 012
HygrostatMFR 012
Connection diagram
Examples of connection
Filter fan, Cooling equipment, Signal device
Art. No. Setting range32038 35 to 95% RH
50 51
• Adjustable and pre-set relative humidity• Optical operating display (LED)• High switching capacity• Clip fixing• Temperature-compensated
The electronic hygrostat senses the relative humidity in an enclosure with electric/electronic components, and turns on a heater at the set point, help-ing prevent the formation of condensation in the enclosure. The LED integrat-ed in the adjustment knob is lit when the connected heater is in operation.
Electronic
Hygrostat - EFR 012
Technical Data:Switch difference 5% RH (±1% RH tolerance) at 25°C (50% RH)Reaction time Approx. 5 sec.Contact type Change-over contact (relay)Service life >50,000 cyclesMax. switching capacity (relay output)
240VAC, 8 (1.6) A120VAC, 8 (1.6) A24VDC, 4A
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Optical indicator LEDConnection 5-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 64.5x42x38mmWeight Approx. 70gFitting position VerticalOp/storage temp. 0 to +60°C / -20 to +70°CMax storage humidity 90% RH (without condensation)Protection type IP20
HeaterHygrostatEFR 012
Connection diagram
Example of connection
Art. No. Operating voltage Setting range Approvals230VAC, 50/60Hz 40 to 90% RH VDE, (UL intended)230VAC 50/60Hz 65% RH pre-set VDE; (UL intended)120VAC, 50/60Hz 40 to 90% RH UL intended120VAC, 50/60Hz 65% RH pre-set UL intended
4 Heater
50 51
• Temperature and humidity adjustable• Optical operating display (LED)• High switching capacity• Clip fixing
The electronic hygrotherm senses the ambient temperature and relative humidity in an enclosure with electric/electronic components, and turns on a heater (or alternatively, a fan) at either set point, helping prevent the formation of condensation in the enclosure. The LED integrated in the adjustment knob on the active controller is lit when the connected device is in operation.
Electronic
Hygrotherm - ETF 012
Technical Data:Switch difference (temperature) 2K (±1K tolerance) at 25°C (50% RH)Switch difference (humidity) 4% RH (±1% tolerance) at 25°C (50% RH)Reaction time (humidity) Approx. 5 sec.Contact type Change-over contact (relay)Contact resistance <10mΩService life NC >50,000 cycles
NO >100,000 cyclesMax. switching capacity (Relay out-put)
NC 240VAC, 6 (1) ANO 240VAC, 8 (1.6) ANC 120VAC, 6 (1) ANO 120VAC, 8 (1.6) A24VDC, 4A
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3Optical indicator LEDConnection 5-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic according to UL94 V-0, light greyDimensions 77x60x43mmWeight Approx. 0.2kgFitting position VerticalOp/storage temp. 0 to +60°C / -20 to +80°CProtection type IP20
HygrothermETF 012
Heater
Connection diagram
Example of connection
Art. No. Operating volt-age
Setting range temperature
Setting range humidity Approval
230VAC, 50/60Hz 0 to +60°C 50 to 90% RH VDE + UL FIle No. E164102120VAC, 50/60Hz +32 to +140°F 50 to 90% RH UL File No. E164102120VAC, 50/60Hz 0 to +60°C 50 to 90% RH UL File No. E164102
52 53
• Compact design• Set temperature • High switching capacity
Compact small mechanical thermostat for temperature regulation and moni-toring of heaters in, for example, transmitter cabinets, control panels and measuring equipment which are deployed in areas with explosion hazard. The special switch construction enables high response accuracy, small switch temperature difference and a very long service life. High switching performance allows direct control of the heaters.
Hazardous area
Thermostat - REx 011 Series
Technical Data:Explosion proof acc. to EN LCIE (Laboratoire Central des Industries Electriques)Conformity certificate 01 ATEX 6074/02, LCIE Nº 06 ATEX 08011, IECEx LCI 07. 0021Sensor element Thermostatic bimetalContact type (1-pole) Opens with rising temperatureService life >100,000 cyclesMax. switching capacity 250VAC, 4 (1) AConnection Si HF - JZ 3x0.75mm2, length 1mMounting mounting bracket with nut M8 (see illustration)Casing Aluminium, black anodisedDimensions length 110mmWeight Approx. 0.2kgFitting position VariableOp/storage temp. -20 to +40°C / -45 to +70°CProt. type/ Prot. class IP65 / I (earthed)
AluminiumMounting Bracket
Art. No. Ex protection type Swich-off temperature Switch temperature differenced IIC T6 - Ex tD A21 IP6X T85°C +15°C (±4K tolerance) 4K (±1K tolerance)d IIC T6 - Ex tD A21 IP6X T85°C +25°C (±4K tolerance) 4K (±1K tolerance)
15°C, 25°C
52 53
• Slim casing• Electronic ballast• Lamp without/with electrical socket (choice of sockets)• Magnet fixing (option)• Energy saving lamp• On/Off switch
The flat slimline lamp SL 025 is suitable for all types of panels and enclo-sures, especially where space is at a premium. The lamp can be mounted on its narrow or broad surface using screws. It is also available with a magnet which allows it to be fitted quickly in any position in a steel enclosure. Both versions are available with an integrated electrical socket enabling the use of additional appliances.
Slimline
Lamp - SL 025 Series
with on/off switch
Technical Data:Power consumption 11W (equals 75W light bulb)Luminosity 900LmLamp type Energy saving lamp, 2G7 socketService life 10,000hSwitch On/off light switchConnection Terminal 2.5mm2 with cable clamp, torque 0.8Nm max.Mounting Screw fixing, M5, 300mm centers
magnet fixing (optional)Casing Plastic acc. to UL94 V-0, light greyDimensions 345x91x40mmFitting position Narrow surface/broad surfaceOp/storage temp. -20 to +50°C / -45 to +75°CProtection type IP20Note The slimline lamp SL 025 is also available with a 19” front panel
24VDC to 48VDC on request
Art. No. Model Operating volt-age
Socket Nominal Current Weight (approx)
Protection class Approvals
without magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.5kg I (earthed) VDE
without magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.4kg I (earthed) UL File No. E234324with magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.5kg I (earthed) UL File No. E234324
without magnet 230VAC, 50/60Hz none - 0.4kg II (double insulated) VDE + UL File No. E234324with magnet 230VAC, 50/60Hz none - 0.5kg II (double insulated) VDE
without magnet 120VAC, 50/60Hz none - 0.4kg II (double insulated) UL File No. E234324with magnet 120VAC, 50/60 Hz none - 0.5kg II (double insulated) UL File No. E234324
Phot
o: S
limlin
e lam
p w
ith o
n/of
f sw
itch,
with
inte
-gr
ated
elec
tric
sock
et (G
erm
any),
Art
No.
54 55
• Slim casing• Electronic ballast• Lamp without/with electrical socket (choice of sockets)• Magnet fixing (option)• Energy saving lamp• On/Off switch
The flat slimline lamp SL 025 with movement sensor is suitable for all types of panels and enclosures, especially where space is at a premium. The lamp can be mounted on its narrow or broad surface using screws. It is also available with a magnet which allows it to be fitted quickly in any position in a steel enclosure. Both versions are available with an integrated electri-cal socket enabling the use of additional appliances. The movement sensor substitutes a door contact switch.
Slimline
Lamp - SL 025 Series
with movement sensor
Technical Data:Power consumption 11W (equals 75W ligth bulb)Luminosity 900LmLamp type Energy saving lamp, 2G7 socketService life 10,000hSwittch PIR movement sensor, approx. 6min. fixed switch-on durationConnection Terminal 2.5mm2 with cable clamp, torque 0.8Nm max.Mounting Screw fixing, M5, 300mm centers
magnet fixing (optional)Casing Plastic acc. to UL94 V-0, light greyDimensions 345x91x40mmFitting position Narrow surface/broad surfaceOp/storage temp. 20 to +50°C / -45 to +70°CProtection type IP20Note The slimliine lamp SL 025 is also available with a 19” front panel
24VDC to 48VDC on request
Art. No. Model Operating volt-age
Socket Nominal Current Weight (approx)
Protection class Approvals
without magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.4kg I (earthed) VDEwith magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.5kg I (earthed) VDE
without magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.4kg I (earthed) UL File No. E234324with magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.5kg I (earthed) UL File No. E234324
without magnet 230VAC, 50/60Hz none - 0.4kg II (double insulated) VDE + UL File No. E234324with magnet 230VAC, 50/60Hz none - 0.5kg II (double insulated) VDE
without magnet 120VAC, 50/60Hz none - 0.4kg II (double insulated) UL File No. E234324with magnet 120VAC, 50/60 Hz none - 0.5kg II (double insulated) UL File No. E234324
Phot
o: S
limlin
e lam
p w
ith m
ovem
ent s
enso
r and
with
in
tegr
ated
elec
tric
sock
et (G
erm
any),
Art
No.
The PIR movement sensor switches the lighting on when the enclosure door is opened. The switch-on timne is reset with every further registered movement. The movement sensor does not react to mevement on the other side of glass and so can be used in enclosures with glass doors.
54 55
• Versatile - base lamp or hand lamp• Long-life energy saving lamp• Connections for further lamps
On/off switch
Dual Lamp - DL 026 Series
Technical Data:Luminosity 1000LmLamp type Energy saving lamp, E27 socketService life 10,000hSwitch On/off push switchConnection 6-pole screw connector 2.5mm2 (torque 0.5Nm max.) for power connection,
further lamps and external door contact switchMounting Screw fixing, (e.g. 35mm DIN rail)Casing Plastic acc. to UL94 V-0, light greyWeight Approx. 0.6kgFitting position VariableOp/storage temp. -20 to +50°C / -45 to +70°CProt. type/prot. class IP20 / II (double insulated)Approvals -Accessories Wall holder with connection cable (2m), hook and fixing plateNote 120VAC and DC voltages on request
Art. No. Operating voltage Power Consumption 230VAC, 50Hz 20W (equals 100W light bulb)
Dual
lamp
with
on/
off s
witc
h (in
cl. b
ase
stat
ion)
1. Standard screw fixing to DIN rail2. 2 self-adhesive fixing plates3. Wall holder with connection cable (2m), hook and self-adhesive fixing plate
By using an additional wall holder the lamp can be used as a hand lamp.
56 57
• Versatile - base lamp or hand lamp• Long-life energy saving lamp• Automatic switching• Alternative solution for door switch• Connections for further lamps
Movement sensor
Dual Lamp - DL 026 Series
Technical Data:Luminosity 1000LmLamp type Energy saving lamp, E27 socketService life 10,000hSwitch PIR movement sensor, approx. 3min. fixed switch-on durationConnection 4-pole screw connector 2.5mm2 (torque 0.5Nm max.) for power connection
and further lampsMounting Screw fixing, (e.g. 35mm DIN rail)Casing Plastic acc. to UL94 V-0, light greyWeight Approx. 0.6kgFitting position VariableOp/storage temp. -20 to +50°C / -45 to +70°CProt. type/prot. class IP20 / II (double insulated)Approvals -Accessories Wall holder with connection cable (2m), hook and fixing plateNote 120VAC and DC voltages on request
The PIR movement sensor switches the lamp on when the enclosure door is opened. The switch-on time is reset with every further registered movement. The movement sensor does not react to mevement on the other side of glass and so can be used in enclosures with glass doors.
Art. No. Operating voltage Power Consumption 230VAC, 50Hz 20W (equals 100W light bulb)
Dual
lamp
with
mov
emen
t sen
sor (
incl.
bas
e st
atio
n)
1. Standard screw fixing to DIN rail2. 2 self-adhesive fixing plates3. Wall holder with connection cable (2m), hook and self-adhesive fixing plate
By using an additional wall holder the lamp can be used as a hand lamp.
56 57
• Long-life energy saving lamp• Versatile
With lamp holder
Hand Lamp - DL 026 Series
Technical Data:Luminosity 1000LmLamp type Energy saving lamp, E27 socketService life 10,000hConnection Power cable (2m) with Euro plugMounting Screw or fixing plate (self-adhesive)Casing Plastic acc. to UL94 V-0, light greyWeight Approx. 0.6kgFitting position VariableOp/storage temp. -20 to +50°C / -45 to +70°CProt. type/prot. class IP20 / II (double insulated)Approvals -Accessories Lamp holder, hook and fixing plateNote 120VAC and DC voltages on request
Art. No. Operating voltage Power Consumption 230VAC, 50Hz 20W (equals 100W light bulb)
58 59
• Magnetic or optional DIN rail mounting• Energy-saving lamp• Lamp without(with electrical socket (choice of sockets)• On/off switch
The compact lamp KL 025 was especially designed for use in enclosures. A powerful magnet enables the lamp to be mounted freely in any desired position in metal enclosures saving time and installation problems. The integrated elec-trical socket allows the use of additional appliances.
Compact
Lamp - KL 025 Series
Technical Data:Luminosity 900LmLamp type Compact fluorescent lamp with integral starterService life 5,000hSwitch On/off light switchConnection 3-pole terminal 2.5mm2 with cable clamp, torque 0.8Nm max.Mounting Magnet fixingCasing Plastic, light greyDimensions 355x65x70mmWeight Approx. 1kgFitting position VariableOp/storage temp. -20 to +50°C / -45 to +70°CProtection type IP20Accessories Lamp cover, Art. No. (see photo)
Art. No. Operating voltage Socket Power consumption Nominal Current Protection class Approvals 230VAC, 50Hz Germany/Russia (1) 11W (equals 75W light bulb) 16.0A I (earthed) VDE
230VAC, 50Hz none 11W (equals 75W light bulb) - II (double insulated) -230VAC, 50Hz F/PL/CZ/SK (2) 11W (equals 75W light bulb) 16.0A I (earthed) -230VAC, 50Hz Switzerland (3) 11W (equals 75W light bulb) 10.0A I (earthed) -230VAC, 50Hz UK/Ireland (4) 11W (equals 75W light bulb) 13.0A I (earthed) -230VAC, 50Hz Italy (6) 11W (equals 75W light bulb) 16.0A I (earthed) -120VAC, 60Hz USA/Canada (5) 9W (equals 60W light bulb) 15.0A I (earthed) -120VAC, 60Hz none 9W (equals 60W light bulb) - II (double insulated) -
In plastic, aluminium or stainless steel cabinets the lamp can be fixed using screws together with inserted 35mm DIN rail sections.
Magnet
Lam
p sh
own
with
pro
tect
ive p
lastic
cov
er (s
ee A
cess
ories
)
58 59
Connections from mains
• Quickly connected• Available with or without fuse• Clip fixing
The DIN rail mounted electrical socket can be quickly fitted and connected in enclosures allowing the use of auxiliary products such as hand lamps, mea-suring devices, soldering irons etc. The unit is available with and without fuse and in many world socket standards.
Electrical
Socket - SD 035 Series
Technical Data:Connection 3 x pressure clamps for stranded and rigid wire 0.5 - 2.5mm2
Mounting Clip for 35mm DIN rail, EN60715Casing Plastic acc. to UL94 V-0, light greyDimensions 92 x 62 x 48mmWeight Approx. 0.2kgFitting position VariableOp/storage temp. -45 to +70°CProt. type/prot. class IP20 / I (earthed)
Art. No. Operating voltage Socket Model Nominal Current Approvals 250VAC Germany/Russia (1) with fuse* 6.3A -
250VAC Germany/Russia (1) without fuse 16.0A -250VAC F/PL/CZ/SK (2) with fuse* 6,3A -250VAC F/PL/CZ/SK (2) without fuse 16.0A -250VAC Switzerland (3) with fuse* 6.3A -250VAC Switzerland (3) without fuse 10.0A -250VAC UK/Ireland (4) with fuse* 6.3A -250VAC UK/Ireland (4) without fuse 13.0A -125VAC USA/Canada (5) with fuse* 6.3A UL File No. E222026125VAC USA/Canada (5) without fuse 15.0A UL File No. E222026250VAC Italy (6) with fuse* 6.3A -250VAC Italy (6) without fuse 16.0A -
* fuse Ø 5x20mm
60 61
• High degree of protection• Easy to install
It has become more and more important to provide a protected enclosure environment for valuable and crucial electrical and electronical components. In a tightly closed enclosure, pressure differentials can occur during extreme temperature variations, such as day/night operation. When this occurs, the risk of dust and humidity being absorbed into the control panel increases dramatically.The specially designed pressure compensation plug DA 084 per-mits a controlled change in pressure. It can be installed easily in any enclo-sure. Because of the pressure compensation plug’s high degree of protection (IP45), the protection type of the enclosure will not be affected.
Pressure compensation
Device - DA 084
Installation:Make cut-out Ø37+¹mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.
Technical Data:Mounting PG29 thread with union nutMaterial Plastic acc. to UL94 V-0Air interface Approx. 7cm2
Dimensions Ø65.5x30.5mmFitting position VariableOp/storage temp. -45 to +70°C
Art. No. Model Protection type 1 packing unit Weight (approx.) without gasket IP45 2 pieces 62g (31g/piece)
with gasket IP55 2 pieces 62g (31g/piece)
IP45/IP55
Photo: Inside view
60 61
• High degree of protection• Semipermeable membrane• Easy to install
Pressure differentials in enclosures with a high degree of protection with respect to humidity and dust are a result of inside and outside temperature fluctuations. In case of negative pressure or vacuum, dust and humidity can be absorbed through the door seal and can enter the enclosure. As the humidity cannot exit the enclosure condensation may occur. The easy to install pressure compensation device DA 284 provides the compensation of pressure at a protection degree of IP66. A semipermeable membrane inside the plug allows air and humidity to leave the enclosure. In the opposite direc-tion, it only allows dry air into the enclosure while humidity and dust from the outside are blocked by the membrane.
Pressure compensation
Device - DA 284
Installation:Make cut-out Ø40.5+0.5mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.
Technical Data:Mounting Thread M40 x 1.5 with nutDepth in enclosure Approx. 16mmMaterial Plastic, light greySealing Sealing gasket NBRFilter Semipermeable membraneAir permeability 1200 l/h at a pressure difference of min. 70mbarDimensions Ø60x37mmFitting position VariableOp/storage temp. -45 to +70°C
Art. No. Protection type 1 packing unit Weight (approx.) IP66 (EN 60529) / IPX9K (EN 40050-9) 2 pieces 90g (45g/piece)
IP66 (EN 60529) / IPX9K (EN 40050-9) 1 piece 45g
IP66
Photo: Inside view
62 63
• High degree of protection• Semipermeable membrane• Corrosion resistant• Food safe
Pressure differentials in enclosures with a high degree of protection with respect to humidity and dust are a result of inside and outside temperature fluctuations. In cas of negative pressure or vacuum, dust and humidity can be absorbed through the door seal and can enter the enclosure. As the hu-midity cannot exit the enclosure condensation may occur. The easy to install pressure compensation device DA 284 provides the compensation of pres-sure at a protection degree of IP66. A semipermeable membrane inside the plug allows air and humidity to leave the enclosure. In the opposite direction, it only allows dry air into the enclo-sure while humidity and dust from the outside are blocked by the membrane.
Pressure compensation
Device - DA 284
Installation:Make cut-out Ø40.5+0.5mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.
Technical Data:Mounting Thread M40 x 1.5 with nutDepth in enclosure Approx. 9mmMaterial Stainless steel V2A (DIN 1.4404 / AISI 316L)Sealing Sealing gasket NBRFilter Semipermeable membraneAir permeability 1200 l/h at a pressure difference of min. 70mbarDimensions Ø58x31mmFitting position VariableOp/storage temp. -45 to +70°C
Art. No. Protection type 1 packing unit Weight (approx.)IP66 (EN 60529) / IPX9K (EN 40050-9) 1 piece 160g
IP66
Photo: Inside view
62 63
Art. No. 1 packing unit Weight (approx.)5 pieces 60g (12g/piece)
Sanofix is an appliance holder for direct fixing of small appliances and perfo-rated 35mm DIN rails.
With Sanofix small appliances can be mounted in switch cabinets significant-ly quicker, easier and more economically than before, without drilling holes. Mounting DIN rails is a simple matter with Sanofix. Longer rails are mounted on several Sanofix units and joining two rails is also not a problem. Subsequent changes and the mounting of additional appliances can be car-ried out with ease - even in confined spaces.
Sanofix is a self-adhesive plastic unit with an adhesion power which will bear a continuous load of 500g. The high-perfor-mance industrial adhesive band is also non-ageing and designed with safety tolerances.
Self-adhesive
Sanofix - Appliance Holder
Load 500g 24h waiting period*Mounting Self-adhesive (non-ageing, high-performance adhesive band)Material Plastic acc. to. UL94 V-0Dimensions 43x38x14mmScrew pitch 12.8mm; Ø3.6mm, for perforated 35mm DIN railOp./storage temperature -45 to 70˚C *Depending on the conditions of use (e.g. surface condition, size of the device to be mounted, etc.) higher loads are possible.
Technical Data:
SANOFIX
Installation:Sanofix can only be mounted on smooth surfaces, e.g. metals, lacquered surfaces and plastics (except poly-ethylene, polypropylene and rubber). The surfaces must be dry, free from dust, oil, separating agents and other contamination.
Application examples:
Holes for screw fixing
Self-adhesive surface Protective film
64 65
What’s needed:1. The dimensions of the enclosure (height, width, depth) (m)2. The enclosure position (e.g. single enclosure, enclosure in row) according to calculation formula, enclosure surface area A (m²)3. The enclosure material (metal, plastic) heat transfer coefficient from table, k (W/m² K)4. The temperature difference between desired enclosure interior temperature Ti (°C) and the expected ambient temperature Tu (°C) (e.g. day - night, summer - winter, climate zones) ∆T (K=Kelvin)5. The stray power (self-warming) of all installed components during operation (e.g. transformers, relays, semiconductors) PV (W)
Calculation and selection of parameters: enclosure surface area - heat transfer coefficient - temperature difference
1. Enclosure surface area from dimensions2. Enclosure position (plan view) acc. to VDE 0660 part 500 Formular for cabinet surface area A (m²) H = height - W = width - D = depth Single enclosure free on all sides A = 1.8 x H x (W + D) + 1.4 x W x D Single enclosure, wall mounted A = 1.4 x W x (H + D) + 1.8 x D x H First or last enclosure in free standing row A = 1.4 x D x (H + W) + 1.8 x W x H First or last enclosure in wall mounted row A = 1.4 x H x (W + D) + 1.4 x W x D Middle enclosure in free standing row A = 1.8 x W x H + 1.4 x W x D + D x H Middle enclosure in wall mounted row A = 1.4 x W x (H + D) + D x H Middle enclosure in wall mounted row with covered top A = 1.4 x W x H + 0.7 x W x D + D x H
Example.: Enclosure free on all sides, 2000mm high / 800mm wide / 600mm deep. A = 1.8 x 2.0 x (0.8 + 0.6) + 1.4 x 0.8 x 0.6 = 5.712m²
3. Enclosure material and its heat transfer coefficient k (W/m² K) 4. Temperature difference ∆T (K=Kelvin) Steel sheet, painted k~5.5W/m² K ∆T = Ti - Tu Steel sheet, stainless k~4.5W/m² K Aluminium k~12W/m² K i.e. the temperature difference between interior and exterior Aluminium, double-walled k~4.5W/m² K temperatures. Polyester k~3.5W/m² K
Calculation formula for required heating performance (heater):Required heating performance PH (W) = enclosure surface area A (m²) x heat transfer coefficient k (W/m² K) x temperature difference ∆T (K)Example.: W = 5.712m² x 5.5W/m² K x 15K = 471.24WResult: Heater with 500W heating performance is required. If enclosure is situated outdoors the calculated heating performance must be doubled!
Or choose required heating performance from diagram:
5. In case of continuous stray power PV (W) (self-warming) this must be deducted from the calculated heating performance.
Choose required cooling performance from diagram:Or calculate using formula for required cooling performance (filter fan):
Required air volume V (8m³/h) = installed stray power Pv(W) x air constant f* (3.3m³K/Wh) temperature difference ∆T (K)
Example.: V = 600W x 3.3m³K/Wh = 132m³/h 15K
*f(0-100)=3.1m³ K/Wh, f(100-250)=3.2m³K/Wh, f(250-500)=3.3³K/Wh, f(500-750)=3.4m³K/Wh, f(750-1000)=3.5m³K/Wh
Varmeydelsesdiagram
Skabets overfladeareal m2
Varm
eyd
else
W
Luftmængde (m3/time)
Spre
dn
ing
seff
ekt
Pv (
W)
Calculation of temperature control in enclosures
Heating performance diagram
Enclosure surface area m²
Heat
ing
perfo
rman
ce W
Air Volume (m³/h)
Tem
pera
ture
diffe
renc
e ∆T
Stra
y po
wer
Pv
(W)
64 65
UK:
Harold [email protected]
tel.: +44 1432 851999mobile: +44 7802 853862
Denmark, Mainoffice:
Gillelejevej 30bDK-3230 Graested
[email protected].: +45 4839 8888fax: +45 4839 8898
Germany:
Wolfgang [email protected]
tel.: +49 6171 887 724mobile: +49 1622 793 484
Member of the NIBE Group
• Process Heating• Heating Elements• Heating Cables• Finned Tubular Radiators• Immersion Heaters• Church Heating• Frost Protection• Ex-Material• Oilfilled Radiators• Drum Heaters• Heating Pads• Flow Heaters• Air Duct Heaters• High-voltage• Resistors• Controllers
With more than 50 years of experience SAN Electro Heat’s most valu-able asset is special knowhow about design, product development and manufacturing of professional electrical heating equipment for industrial use.
The company is geared to deliver 100% customized products, and thus functions both as a catalyst for a development project and as supplier of the final product. At the same time we insure and maintain the required quality level, mechanical and electrical dimensioning, approvals and documentation.
2015 J
anuary
30th
www.san-as.com