  • The Room Pressure Monitor (PM) is designed specifically to meet the needs of Compounding Pharmacies,

    Isolation Rooms and Operating Rooms. The PM provides single pressure monitoring while utilizing

    industry-first maintenance-free pressure sensors.

    The PM features visual and audible alarms signaling unsafe conditions. Illuminating sidebars provide 180

    degree visual status from anywhere in the corridor. Audible alarms are available for additional room

    status indication ensuring building staff are able to verify changes in room status immediately.

    The PM measures the differential room pressure through the Room Pressure Sensor (RPS) assembly.

    2 For more information visit www.AntecControls.com | v103

    PMRoom Pressure Monitor

  • ROOM PRESSURE SENSING The PM provides pressure measurement through an industry-

    first maintenance-free Room Pressure Sensor (RPS). As a result,

    the RPS is highly accurate with minimal drift over time. When

    tested against competing technologies, including

    diaphragm sensors and thermal anemometers, the RPS has

    proven to be the most durable pressure sensing technology.

    Comparison of Antec Controls sensor to diaphragm sensor technology. Comparison of published accuracies.

    0.020

    0.018

    0.016

    0.014

    0.012

    0.010

    0.008

    0.006

    0.004

    0.002

    0.0000 1 2 3 4

    Time (Years)

    Room

    Pre

    ssur

    e

    Antec Controls Diaphragm SensorReference Pressure

    Comparison of Antec Controls sensor to thermal anemometer sensor technology. Effects of a lint and dust saturated environment.

    0.016

    0.014

    0.012

    0.010

    0.008

    0.006

    0.004

    0.002

    0.0000 50 100 150 200 250

    Room

    Pre

    ssur

    e

    Antec Controls Thermal Anemometer SensorReference Sensor

    Time (Days)

    TYPICAL APPLICATIONSThe PM provides precise room

    pressure monitoring for critical

    spaces. Using a maintenance-

    free room pressure sensor

    (RPS), the PM can accurately

    measure room pressure without

    the risk of degradation over time.

    APPLICATIONS + Compounding Pharmacies

    + Operating Rooms

    + Isolation Rooms

    FEATURES+ 24/7 pressure monitoring

    + LED sidebars with 180 degree viewing

    + Maintenance-free pressure measurement

    + Password protected menus

    STANDARDS & CERTICATIONS

    + ASHRAE 170 Healthcare Ventilation Standard

    + USP 800 and USP 797 Hazardous Drugs – Handling in Healthcare Settings

    3v103 | For more information visit www.AntecControls.com

    PM Room Pressure Monitor

  • 4 For more information visit www.AntecControls.com | v103

    PMRoom Pressure Monitor

    DIMENSIONAL DATA

    3.5” clearance from wall for bend radius of cable

    4.6” W

    4.5” H

    2” D

  • EngineeringRequestNo:

    (yyy

    y/m

    m/d

    d)

    Initia

    lsCo

    mpl

    etio

    nda

    teFa

    ctor

    yor

    dern

    oO

    pera

    tor

    Sch

    date

    Part

    qty

    Shee

    t

    of

    Revi

    sion

    Desc

    riptio

    n

    Draw

    ing

    no.

    Date

    Stat

    us

    Draw

    nby

    Scal

    e

    Com

    men

    t/Tag

    Issu

    edda

    teBl

    ank

    qty

    2017

    /09/

    14

    PCC

    PMT

    01

    1So

    lidEd

    ge

    LPN

    TS

    RevDe

    scrip

    tion

    ECN

    Date

    (y/m

    /d)By

    ������

    ����

    ����

    ������

    ����

    ����

    ����

    EngineeringRequest No:

    (yyy

    y/m

    m/d

    d)

    Initi

    als

    Com

    plet

    ion

    date

    Fact

    ory

    orde

    rno

    Ope

    rato

    rSc

    hda

    tePa

    rtqt

    y

    Shee

    t

    of

    Rev

    isio

    n

    Des

    crip

    tion

    Dra

    win

    gno

    .D

    ate

    Stat

    us

    Dra

    wn

    bySc

    ale

    Com

    men

    t/Tag

    Issu

    edda

    teBl

    ank

    qty

    2017

    /09/

    14

    PCC

    RPS

    01

    1So

    lidEd

    ge

    LPNT

    S

    Rev

    Descrip

    tion

    ECN

    Date

    (y/m

    /d)By

    ����

    ����

    ����

    ����

    ����

    ����

    ����

    ����

    SPECIFICATIONS

    5v103 | For more information visit www.AntecControls.com

    PM Room Pressure Monitor

    TYPICAL WIRING

    Mute

    NORMAL

    Emergency

    EnterMenu

    ALARM

    ROOM PRESSURE INTERFACE

    24VAC

    PLUG AND PLAY RJ12/LOCKING CIRCULAR CONNECTION

    ROOM PRESSURE SENSOR (RPS)

    )

  • Product Improvement is a continuing endeavour at Antec Controls by Price. Therefore, specifications are subject to change without notice. Consult your Sales Representative for current specifications or more detailed information. Not all products may be

    available in all geographic areas. All goods described in this document are warranted as described in the Limited Warranty. The complete product catalog can be viewed online at AntecControls.com

    ® Antec Controls by Price is a registered trademark of Price Industries Limited. © 2020. Printed in Canada. v103