20032_HHW Sheet No.: Scale: Status: Project Name Client Plot Date: HOCKEY HALL Project No: Drawing Title: The builder shall check and verify all dimensions and levels on site. All errors and omissions to be verified with the Designer before commencment on site. Do not scale the drawings. Drawings shall not be used for construction purposes until issued for construction. REV DATE AMENDMENT 31/3/20 /Volumes/Data/01 PROJECTS/01_CURRENT/20032 WALCHA COMMUNITY PROJECTS/HOCKEY HALL/20032_HH_ST1.pln 43-60 JAMIESON STREET WALCHA NSW 2354 WALCHA SHIRE COUNCIL 1:100, 1:200, 1:1000 PRELIMINARY WD1 EXISTING/DEMOLITION PLAN All boundary locations and levels to be confirmed by a registered surveyor. All underground service location's to be confirmed. Obtain and confirm all service connection approvals and requirements before commencing onsite. D&C PROJECT S DT 10 30 40 50 100 150 20 length in millimeters at full size 200 10 30 40 50 100 150 20 length in millimeters at full size 200 EXISTING 2,350 EXISTING 8,680 EXISTING 14,465 EXISTING 7,395 EXISTING 6,190 EXISTING 2,730 EXISTING 10,000 EXISTING 2,730 EXISTING 2,350 EXISTING 30,540 EXISTING 6,190 EXISTING 15,460 EXISTING 32,890 EXISTING 21,650 EXISTING 32,890 EXISTING 21,650 600 450 600 450 EXISTING HALL EXIST. MALE WC EXISTING KITCHEN EXIST. FEMALE WC EXIST. SLAB EXIST. STORE EXIST. ENTRY STAGE 1: - REMOVE EXISTING ROOF SHEETING TO HALL ROOF, KITCHEN AND AMENITIES ROOF. (ENTRY AND FRONT STORE ROOF TO REMAIN) - REPAIR AND REPLACE EXISTING HALL STRUCTURE WHERE NECESSARY. - REPAIR OR REPLACE EXISTING GUTTERS, FASCIAS, DOWNPIPES AND BARGES. PROVIDE ADDITIONAL DOWNPIPES IF NECESSARY TO ASSIST WITH STORMWATER REMOVAL. - REPLACE ROOF SHEETING OVER HALL WITH NEW SARKING AND WIRE SAFETY MESH. - REPLACE CEILING LINING TO UNDERSIDE OF HALL ROOF STRUCTURE TO MATCH EXISTING. - REMOVE EXISTING MESH EAVE LINING AND PROVIDE NEW LOW MAINTENANCE EAVE SHEETING TO PREVENT NESTING OF BIRDS. - PROVIDE NEW INSULATED ROOF OVER OFFICE AND AMENITIES AREAS (RECOMMEND R3.5 INSULATION) WITH SAFETY MESH AND SARKING. - PROVIDE NEW CEILING LINING OVER OFFICE AND AMENITIES. ENSURE WATERPROOF OR MOISTURE RESISTANT LININGS OVER AMENITIES. CARRY OUT ALL WORKS IN ACCORDANCE WITH MANUFACTURES AND ENGINEERS DETAILS. ENSURE WORK IS CARRIED OUT BY A SUITABLY QUALIFIED CONSULTANT OR TRADESPERSON. ENSURE WORK IS CARRIED OUT IN ACCORDANCE WITH RELEVANT BUILDING CODES AND AUSTRALIAN STANDARDS. ALL MEASUREMENTS ARE INDICATIVE ONLY AND SHOULD BE CONFIRMED ONSITE BEFORE COMMENCEMENT OF WORKS. APPROX BOUNDARY 36 400 APPROX BOUNDARY 17 400 APPROX BOUNDARY 9 550 APPROX BOUNDARY 33 400 APPROX BOUNDARY 26 950 APPROX BDY 3 000 DERBY STREET JAMIESON STREET EXISTING HALL EXISTING CAR PARKING AREA LOT 2 DP 759035 APPROX SITE AREA: 952.4m 2 EXISTING HALL N EXISTING FLOOR AREAS EXISTING BUILDING AREA 585.2m² EXISTING EXTERNAL CONCRETE AREA 58.9m² TOTAL EXISTING 644.1m² LEGEND WT WATER TANK TP TIMBER POST BP BRICK PEIR SC STEEL COLUMN SMOKE ALARM 350Hx500W NICHE DP DOWN PIPE ST STOVE SNK SINK WC WATER CLOSET SHR SHOWER RC REINFORCED CONCRETE WM WATER METER CL CLOTHES LINE FW FLOOR WASTE HWU HOT WATER UNIT MSB MAIN SWITCH BOARD FFL FINISHED FLOOR LEVEL FSL FINISHED SLAB LEVEL EGL EXISTING GROUND LEVEL FGL FINISHED GROUND LEVEL SA DEVELOPMENT NOTES ALL BUILDING WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA. PROVIDE DOWN PIPES IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA & AS2180 METAL RAINWATER GOODS. PROVIDE LIFT OFF HINGES TO WC DOORS IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA. WHERE ONSITE STORMWATER DETENTION IS REQUIRED, REFER TO COUNCILS ENGINEERING GUIDELINES FOR SUBDIVISIONS AND DEVELOPMENT. PROVIDE WATERPROOFING SYSTEM TO ALL WET AREAS IN ACCORDANCE WITH CLAUSE 3.8.1 OF THE BCA & AS3740 PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1 INSULATION MUST BE INSTALLED IN ACCORDANCE WITH PART 3.12.1.1 OF THE BUILDING CODE OF AUSTRALIA. INSULATION MUST COMPLY WITH AS/NZS 4859.1 AND THE BASIX CERTIFICATE. ALL LEVELS ARE INDICATIVE AND SHOULD BE CONFIRMED. CONDENSATION MANAGEMENT TO BE INSTALLED IN ACCORDANCE WITH PART 3.8.7 OF THE BUILDING CODE OF AUSTRALIA 00 30/03/20 ISSUED FOR INTERNAL REVIEW DP SITE PLAN SCALE 1:200@A1 SHEET EXISTING FLOOR PLAN SCALE 1:100@A1 SHEET LOCATION PLAN SCALE 1:1000@A1 SHEET AS SHOWN 01 31/03/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB

AND AUSTRALIAN STANDARDS. ALL MEASUREMENTS ARE … · ex ist ngbu ld ar 58 .2m² ... basix certificate. all levels are indicative and should be confirmed. condensation management

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AND AUSTRALIAN STANDARDS. ALL MEASUREMENTS ARE … · ex ist ngbu ld ar 58 .2m² ... basix certificate. all levels are indicative and should be confirmed. condensation management

20032_HHWSheet No.:

Scale:Status:

Project Name

Client

Plot Date:

HOCKEY HALL

Project No:

Drawing Title:

The builder shall check and verify all dimensions and levels on site.All errors and omissions to be verified with the Designer before commencment on site.

Do not scale the drawings.Drawings shall not be used for construction purposes until issued for construction.

REV DATE AMENDMENT

31/3/20

/Volumes/Data/01 PROJECTS/01_CURRENT/20032 WALCHA COMMUNITY PROJECTS/HOCKEY HALL/20032_HH_ST1.pln

43-60 JAMIESON STREETWALCHA NSW 2354

WALCHA SHIRE COUNCIL

1:100, 1:200, 1:1000 @ A1PRELIMINARY

WD1

EXISTING/DEMOLITION PLAN

All boundary locations and levels to be confirmed by a registered surveyor.All underground service location's to be confirmed.

Obtain and confirm all service connection approvals andrequirements before commencing onsite.

D&CP R O J E C T S

DT

10 30 40 50 100 15020 length in millimeters at full size 200

1030

4050

100

150

20le

ngth

in m

illim

eter

s at

full

size

200

EXISTING 2,350 EXISTING 8,680 EXISTING 14,465 EXISTING 7,395

EXIS

TIN

G 6

,190

EXIS

TIN

G 2

,730

EXIS

TIN

G 1

0,00

0EX

ISTI

NG

2,7

30

EXISTING 2,350 EXISTING 30,540

EXIS

TIN

G 6

,190

EXIS

TIN

G 1

5,46

0

EXISTING 32,890

EXIS

TIN

G 2

1,65

0

EXISTING 32,890

EXIS

TIN

G 2

1,65

0

600

450

600

450

EXISTINGHALL

EXIST. MALE WC EXISTING KITCHEN EXIST. FEMALE WC

EXIST. SLAB

EXIST.STORE

EXIST.ENTRY

STAGE 1:

- REMOVE EXISTING ROOF SHEETING TO HALL ROOF, KITCHEN ANDAMENITIES ROOF. (ENTRY AND FRONT STORE ROOF TO REMAIN)

- REPAIR AND REPLACE EXISTING HALL STRUCTURE WHERE NECESSARY.

- REPAIR OR REPLACE EXISTING GUTTERS, FASCIAS, DOWNPIPES AND BARGES. PROVIDEADDITIONAL DOWNPIPES IF NECESSARY TO ASSIST WITH STORMWATER REMOVAL.

- REPLACE ROOF SHEETING OVER HALL WITH NEW SARKING AND WIRE SAFETY MESH.

- REPLACE CEILING LINING TO UNDERSIDE OF HALL ROOF STRUCTURE TO MATCH EXISTING.

- REMOVE EXISTING MESH EAVE LINING AND PROVIDE NEW LOW MAINTENANCE EAVESHEETING TO PREVENT NESTING OF BIRDS.

- PROVIDE NEW INSULATED ROOF OVER OFFICE AND AMENITIES AREAS (RECOMMEND R3.5INSULATION) WITH SAFETY MESH AND SARKING.

- PROVIDE NEW CEILING LINING OVER OFFICE AND AMENITIES. ENSURE WATERPROOF ORMOISTURE RESISTANT LININGS OVER AMENITIES.

CARRY OUT ALL WORKS IN ACCORDANCE WITH MANUFACTURES AND ENGINEERS DETAILS.ENSURE WORK IS CARRIED OUT BY A SUITABLY QUALIFIED CONSULTANT OR TRADESPERSON.ENSURE WORK IS CARRIED OUT IN ACCORDANCE WITH RELEVANT BUILDING CODESAND AUSTRALIAN STANDARDS. ALL MEASUREMENTS ARE INDICATIVE ONLY AND SHOULD BECONFIRMED ONSITE BEFORE COMMENCEMENT OF WORKS.

APPROX BOUNDARY 36 400

APPR

OX B

OUND

ARY

17 40

0

APPR

OX B

OUND

ARY

9 550

APPROX BOUNDARY 33 400

APPR

OX B

OUND

ARY

26 95

0

APPR

OXBD

Y 3 0

00

DE

RB

Y S

TR

EE

T

J A M I E S O N S T R E E T

EXISTINGHALLEXISTING CAR

PARKING AREA

LOT 2DP 759035APPROX SITE AREA: 952.4m2

EXISTINGHALL

N

EXISTING FLOOR AREASEXISTING BUILDING AREA 585.2m²EXISTING EXTERNAL CONCRETE AREA 58.9m²

TOTAL EXISTING 644.1m²

LEGENDWT WATER TANKTP TIMBER POSTBP BRICK PEIRSC STEEL COLUMN SMOKE ALARM 350Hx500W NICHEDP DOWN PIPEST STOVESNK SINKWC WATER CLOSETSHR SHOWERRC REINFORCED CONCRETEWM WATER METERCL CLOTHES LINEFW FLOOR WASTEHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL

SA

DEVELOPMENT NOTESALL BUILDING WORK SHALL BE CARRIED OUT INACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.PROVIDE DOWN PIPES IN ACCORDANCE WITH THE BUILDINGCODE OF AUSTRALIA & AS2180 METAL RAINWATER GOODS.PROVIDE LIFT OFF HINGES TO WC DOORS INACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.WHERE ONSITE STORMWATER DETENTION IS REQUIRED,REFER TO COUNCILS ENGINEERING GUIDELINES FORSUBDIVISIONS AND DEVELOPMENT.PROVIDE WATERPROOFING SYSTEM TO ALL WET AREAS INACCORDANCE WITH CLAUSE 3.8.1 OF THE BCA & AS3740PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1INSULATION MUST BE INSTALLED IN ACCORDANCE WITH PART3.12.1.1 OF THE BUILDING CODE OF AUSTRALIA.INSULATION MUST COMPLY WITH AS/NZS 4859.1 AND THEBASIX CERTIFICATE.ALL LEVELS ARE INDICATIVE AND SHOULD BE CONFIRMED.CONDENSATION MANAGEMENT TO BE INSTALLED INACCORDANCE WITH PART 3.8.7 OF THE BUILDING CODE OFAUSTRALIA

00 30/03/20 ISSUED FOR INTERNAL REVIEW DP

SITE PLANSCALE 1:200@A1 SHEET

EXISTING FLOOR PLANSCALE 1:100@A1 SHEET

LOCATION PLANSCALE 1:1000@A1 SHEET

AS SHOWN

01 31/03/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB

Page 2: AND AUSTRALIAN STANDARDS. ALL MEASUREMENTS ARE … · ex ist ngbu ld ar 58 .2m² ... basix certificate. all levels are indicative and should be confirmed. condensation management

20032_HHWSheet No.:

Scale:Status:

Project Name

Client

Plot Date:

HOCKEY HALL

Project No:

Drawing Title:

The builder shall check and verify all dimensions and levels on site.All errors and omissions to be verified with the Designer before commencment on site.

Do not scale the drawings.Drawings shall not be used for construction purposes until issued for construction.

REV DATE AMENDMENT

31/3/20

/Volumes/Data/01 PROJECTS/01_CURRENT/20032 WALCHA COMMUNITY PROJECTS/HOCKEY HALL/20032_HH_ST1.pln

43-60 JAMIESON STREETWALCHA NSW 2354

WALCHA SHIRE COUNCIL

1:100 @ A1PRELIMINARY

WD2

ELEVATIONS

All boundary locations and levels to be confirmed by a registered surveyor.All underground service location's to be confirmed.

Obtain and confirm all service connection approvals andrequirements before commencing onsite.

D&CP R O J E C T S

DT

10 30 40 50 100 15020 length in millimeters at full size 200

1030

4050

100

150

20le

ngth

in m

illim

eter

s at

full

size

200

FSL

FCL

AP

PR

OX

EX

ISTI

NG

3,80

0

AP

PR

OX

EX

ISTI

NG

2,33

5

AP

PR

OX

EX

ISTI

NG

2,40

0

APPROX600

EXISTING GROUND LEVEL

ROOF PITCH APPROX 2.5°

ROOF PITCH APPROX 15°

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

PROV

IDE

NEW

EAV

E LIN

INGS

TO P

REVE

NT B

IRD

NEST

ING

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

PROV

IDE

NEW

EAV

E LIN

INGS

TO P

REVE

NT B

IRD

NEST

ING

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

REPA

IR, R

EPLA

CE O

R RE

PAIN

TEX

ISTI

NG G

ABLE

FASC

IA B

ARGE

REPA

IR, R

EPLA

CE O

R RE

PAIN

TEX

ISTI

NG G

ABLE

FASC

IA B

ARGE

REPA

IR, R

EPLA

CE O

R RE

PAIN

TEX

ISTI

NG G

ABLE

FASC

IA B

ARGE

FSL

FCL

AP

PR

OX

EX

ISTI

NG

3,80

0

AP

PR

OX

EX

ISTI

NG

2,40

0

AP

PR

OX

EX

ISTI

NG

2,33

5

APPROX450

EXISTING GROUND LEVEL

PITCH APPROX 5°

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

FSL

FCL

AP

PR

OX

EX

ISTI

NG

3,80

0

AP

PR

OX

EX

ISTI

NG

2,40

0

EXISTING GROUND LEVEL

ROOF PITCH APPROX 2.5°

ROOF PITCH APPROX 15°

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

PROV

IDE

NEW

EAV

E LIN

INGS

TO P

REVE

NT B

IRD

NEST

ING

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

PROV

IDE

NEW

EAV

E LIN

INGS

TO P

REVE

NT B

IRD

NEST

ING

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

REPA

IR, R

EPLA

CE O

R RE

PAIN

TEX

ISTI

NG G

ABLE

FASC

IA B

ARGE

REPA

IR, R

EPLA

CE O

R RE

PAIN

TEX

ISTI

NG G

ABLE

FASC

IA B

ARGE

REPA

IR, R

EPLA

CE O

R RE

PAIN

TEX

ISTI

NG G

ABLE

FASC

IA B

ARGE

FSL

FCL

AP

PR

OX

EX

ISTI

NG

3,80

0

AP

PR

OX

EX

ISTI

NG

2,33

5

EXISTING GROUND LEVEL

ROOF PITCHAPPROX 5°

PROV

IDE

NEW

GUT

TER

AND

FASC

IA. P

ROVI

DE A

DDIT

IONA

LDO

WNP

IPES

AS

NECE

SSAR

Y

COLO

RBON

D RO

OF S

HEET

ING

OVER

ADE

QUAT

E SA

FETY

MESH

AND

SAR

KING

LEGENDHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL

DEVELOPMENT NOTESALL BUILDING WORK SHALL BE CARRIED OUT INACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.PROVIDE DOWN PIPES IN ACCORDANCE WITH THE BUILDINGCODE OF AUSTRALIA & AS2180 METAL RAINWATER GOODS.PROVIDE LIFT OFF HINGES TO WC DOORS INACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.WHERE ONSITE STORMWATER DETENTION IS REQUIRED,REFER TO COUNCILS ENGINEERING GUIDELINES FORSUBDIVISIONS AND DEVELOPMENT.PROVIDE WATERPROOFING SYSTEM TO ALL WET AREAS INACCORDANCE WITH CLAUSE 3.8.1 OF THE BCA & AS3740PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1INSULATION MUST BE INSTALLED IN ACCORDANCE WITH PART3.12.1.1 OF THE BUILDING CODE OF AUSTRALIA.INSULATION MUST COMPLY WITH AS/NZS 4859.1 AND THEBASIX CERTIFICATE.ALL LEVELS ARE INDICATIVE AND SHOULD BE CONFIRMED.CONDENSATION MANAGEMENT TO BE INSTALLED INACCORDANCE WITH PART 3.8.7 OF THE BUILDING CODE OFAUSTRALIA

WESTERN - DERBY STREET ELEVATIONSCALE 1:100@A1 SHEET

SOUTHERN ELEVATIONSCALE 1:100@A1 SHEET

EASTERN ELEVATIONSCALE 1:100@A1 SHEET

NORTHERN - JAMIESON STREET ELEVATIONSCALE 1:100@A1 SHEET

00 30/03/20 ISSUED FOR INTERNAL REVIEW DP01 31/03/20 ISSUED FOR CLIENT REVIEW & SIGNOFF SB