20
Federal Department of Home Affairs FDHA Federal Office of Meteorology and Climatology MeteoSwiss Analysis of the long-term profile ozone measurements of MeteoSwiss E. Maillard Barras, R. Stübi, MeteoSwiss, Payerne Payerne ozone sounding series Arosa Umkehr series Microwave SOMORA ozone series

Analysis of the long-term profile ozone measurements of

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Analysis of the long-term profile ozone measurements of

Federal Department of Home Affairs FDHA

Federal Office of Meteorology and Climatology MeteoSwiss

Analysis of the long-term profile ozonemeasurements of MeteoSwiss

E. Maillard Barras, R. Stübi, MeteoSwiss, Payerne

• Payerne ozone sounding series

• Arosa Umkehr series

• Microwave SOMORA ozone series

Page 2: Analysis of the long-term profile ozone measurements of

2SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Ozone sounding from Payerne

2002: Brewer-Mast to ECC sonde1 instrumental change

vertical resolution: 100 mozone profiles from 0 to ~32 km

time resolution: 3 profiles/weekcontinuously operated since 1968

(1966)

• The BM data series have been described in Jeannet et al. (2007),• Ozone balloon soundings at Payerne (Switzerland): Reevaluation of the time series 1967–2002

and trend analysis, J. Geophys. Res., 112, D11302, doi:10.1029/2005JD006862.

• The transition from BM to ECC has been described in Stübi et al. (2008), • In-flight comparison of Brewer-Mast and electrochemical concentration cell ozonesondes, J.

Geophys. Res., 113, D13302, doi:10.1029/2007JD009091

• Comparison of the series with:

• Hohenpeissenberg BM series

• Jungfraujoch high alpine station data

Page 3: Analysis of the long-term profile ozone measurements of

3SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Transition BM to ECC sondes: annual cycles

BM sondes

ECC sondes

• Annual cycles over “last 7 years of

BM ” and “first 7 years of ECC”

• No significant difference

between BM and ECC periods

Page 4: Analysis of the long-term profile ozone measurements of

4SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Tropospheric annual cycles: Payerne vs. MOHp

0 2 4 6 8 10 12

20

30

40

50

Pressure: 900 hPa

0 2 4 6 8 10 12

20

30

40

50

Pressure: 850 hPa

0 2 4 6 8 10 12

20

30

40

50

Pressure: 800 hPa

0 2 4 6 8 10 12

20

30

40

50

Pressure: 700 hPa

0 2 4 6 8 10 122

03

04

05

0

Pressure: 650 hPa

0 2 4 6 8 10 12

20

30

40

50

Pressure: 600 hPa

0 2 4 6 8 10 12

20

30

40

50

Pressure: 500 hPa

0 2 4 6 8 10 12

20

30

40

50

Pressure: 400 hPa

0 2 4 6 8 10 12

20

30

40

50

Pressure: 300 hPa

ECCBMMoHp

Page 5: Analysis of the long-term profile ozone measurements of

5SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Coincident data: Sondes vs. Alpine station JFJ

40

50

60

70

Time

Ozo

ne

[p

pb

]

1990 1995 2000 2005

20 years / monthly mean

ECCBM

Troposphere, Jungfraujoch alt. ~3600 m

Page 6: Analysis of the long-term profile ozone measurements of

6SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Laboratory controlled parameters: bg, high O3, …

5%

1.8 nb

Page 7: Analysis of the long-term profile ozone measurements of

7SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

QC parameters: pump flow rate, correction factor

7%

• Agreement with an independent

ozone column measurement:

1.0 +/- 0.2

• Ozone is proportional to flow rate

• Stability of the production

Page 8: Analysis of the long-term profile ozone measurements of

8SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Ozone trends 1970-1995 vs. 1996-2009

Jeannet et al.(2007), JGR,2005JD006862

Page 9: Analysis of the long-term profile ozone measurements of

9SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

• First order transfer functions for

ECC sondes from field campaigns

=> correcting the data (+/- 2%) for

changes of provider / solution conc.

• Difference 0.5 % => 1.0 %: 5% up to

25 km + add 1% / 2km above

• Difference SPC-1% and ENSCI-

0.5%: not significant (1%)

• Difference ENSCI => SPC with 1%:

3% till 25km + add 1.5% / 2 km

above.

New JOSIE campaign 2009-2010 to

check the recent ECC production.

Correction for change of solution conc.

05

10

15

20

25

30

Altitude [

km

]

KI_1.0 - KI_0.5 / KI_0.5 [%]

0 2 4 6 8 10 12

1000

500

100

50

30

15

Pre

ssure

[hP

a]

05

10

15

20

25

30

Altitude [

km

]

KI_1.0 - KI_0.5 / KI_0.5 [%]

0 2 4 6 8 10 12

1000

500

100

50

30

15

Pre

ssure

[hP

a]

0.8

Page 10: Analysis of the long-term profile ozone measurements of

10SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

• Mean ozone column from SCIAMACHY overpasses

• Mean ozone column from last 7 years of O3-sonding (NAI-std) + conc. correction / back-ground correction

Correction for change of sol. conc. at Nairobi

SCI NAI-std NAI-ib NAI-conc NAI-sync SCI-syn

22

02

40

26

02

80

30

03

20

34

0

Ozo

ne

co

lum

n [D

U]

std

Ib

conc

SCI

conc. +t-coinc.

Page 11: Analysis of the long-term profile ozone measurements of

11SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Umkehr by Dobson sun spectrophotometer

1988: D15 to D511 instrumental change

vertical resolution: 10-15 kmozone profiles from 10 to 50 km

time resolution: 2 prof./day (sr and ss)continuously operated since 1956

(1966)

• Retrieval of ozone profiles: umkv8 of Irina Petropavlovskikh based on OEM by Rodgersdescribed in GRL, VOL. 32, L16808, doi:10.1029/2005GL023323, 2005

• Quality control by redundant measurements

D 051

55 60 65 70 75 80 85 90 95

Solar zenith angle

N v

alu

es

55 60 65 70 75 80 85 90 95

1960 1970 1980 1990 2000

10

20

30

40

50

Altitud

e[k

m]

DU: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

Page 12: Analysis of the long-term profile ozone measurements of

12SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Umkehr by Dobson: N-values QC ...

Instrument change: D15 to D51

Page 13: Analysis of the long-term profile ozone measurements of

13SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Umkehr by Dobson: O3 time series ...L6: 16hPa – 8 hPa

L7: 8hPa – 4 hPa

Page 14: Analysis of the long-term profile ozone measurements of

14SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Umkehr by Dobson: intercomparison results

• GAW report No. 180: Towards a Better Knowledge of Umkehr Measurements: A Detailed Study of Data from Thirteen Dobson Intercomparisons, I. Petropavlovskikh, R. D. Evans, G. L. Carbaugh, E. Maillard and R. Stubi

Page 15: Analysis of the long-term profile ozone measurements of

15SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Ozone microwave radiometer SOMORA

• Retrieval of ozone profiles: ARTS/Qpack based on OEM described in• ERIKSSON, P., et al, 2005, Journal of Quantitative Spectroscopy & Radiative

Transfer, 91, 47–64

• Redundancy with GROMOS radiometer at University of Bern (1995 - now)

2005 : front-end change

2009 : spectrometer change from AOS

to FFT

2 major instrumental changes

vertical resolution: 8 -15 kmozone profiles from 20 to 65 km

time resolution: 30 minutescontinuously operated since 2000

Page 16: Analysis of the long-term profile ozone measurements of

16SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

SOMORA: contribution function and errors

0

10

20

30

40

50

60

70

80

90

100

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

error [ ]

alt

itu

de

[k

m]

Error [% of profile]

Alt

itud

e[k

m]

obs error

smo error

tot error

Page 17: Analysis of the long-term profile ozone measurements of

17SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

SOMORA QC: System temperature

1

)*(

−=

y

yTcThTsys UoffsetUc

UoffsetUhy

−=with

Page 18: Analysis of the long-term profile ozone measurements of

18SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

SOMORA: monthly mean ozone time series

June 2001, mixerreparation

May 2005, front-endchange

Sept 2009, spectrometerchange

Page 19: Analysis of the long-term profile ozone measurements of

19SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

SOMORA spectrometer change: AOS to FFT

AOS 2009 FFT 2009 AOS 2008

Time [1year, 2008 / 2009]

6 hPa ~35 km

8.4 hPa ~31.3 km

12.5 hPa ~28.8 km

6 hPa ~35 km

8.4 hPa ~31.3 km

12.5 hPa ~28.8 km

Page 20: Analysis of the long-term profile ozone measurements of

20SPARC/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, January 25-27 2011

Merging SOMORA and soundings: example

SOMORA measurement errorbelow 20 km is important and the measurement contribution at the altitude range shouldbe reduced to minimum.At this altitude, radiosoundingmeasures ozone with a superior precision.

By combining both profiles weget an ozone profile withreliable values from groundto 60 km.

Consider the radiosoundingas an a priori and retrieveSOMORA ozone profile withan exclusive weight on radiosounding below 25 km