Upload
kefas-coro-balap
View
19
Download
14
Embed Size (px)
DESCRIPTION
Analisis Cahaya
Citation preview
Project 108.10.2012
OperatorTelephone
Faxe-Mail
Room 1 / Light scene 1 / Summary
350
350
350
350
350
350
700
1050
14.00 m0.00 0.80 1.70 2.68 3.49 4.30 5.12 5.95 6.76 7.58 8.37 9.17 9.97 10.77 11.75 12.89
8.50 m
0.00
0.891.35
2.452.843.36
4.044.45
5.185.77
6.627.017.47
Height of Room: 3.000 m, Light loss factor: 0.80 Values in Lux, Scale 1:110
Surface [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 89 3.10 1679 0.035Floor 90 48 3.44 1007 0.071Ceiling 80 70 7.96 281 0.113Walls (4) 50 53 4.00 515 /
Workplane:Height: 0.760 mGrid: 128 x 128 Points Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.635, Ceiling / Working Plane: 0.792.
Pure daylight scene, no luminaires involved.
Page 1
Project 108.10.2012
OperatorTelephone
Faxe-Mail
Room 1 / Light scene 1 / Photometric Results
Total Luminous Flux: 0 lmTotal Load: 0.0 WLight loss factor: 0.80Boundary Zone: 0.000 m
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m] direct indirect total
Workplane 48 41 89 / / Calculation Surface 1 56 48 105 / / Calculation Surface 2 0.00 2.98 2.98 / / Calculation Surface 2 0.00 8.00 8.00 / / Calculation Surface 2 0.00 3.61 3.61 / / Calculation Surface 2 0.00 3.77 3.77 / / Calculation Surface 2 0.00 15 15 / / Floor 32 16 48 90 14Ceiling 0.00 70 70 80 18Wall 1 9.13 65 74 50 12Wall 2 0.00 76 76 50 12Wall 3 7.56 41 49 50 7.81Wall 4 0.00 4.36 4.36 50 0.69
Uniformity on the working planeu0: 0.035 (1:29) Emin / Emax: 0.002 (1:541)
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.635, Ceiling / Working Plane: 0.792.
Specific connected load: 0.00 W/m = 0.00 W/m/ lx (Ground area: 119.00 m)