Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
FILTERS
COALESCERS
ABSORBERS
ELEMENTS
MIST ELIMINATORS
an EnPro Industries company
an EnPro Industries company
COMPRESSED AIR FILTERS
STANDARD FILTERS
Quincy DCN Series
Particulate/Coarse Coalescers are designed to
remove solids, burnt oil and bulk liquids.
Quincy CSN, CPN, CXN Series
Coalescers remove various levels of liquid aero-
sols and mist.
Quincy ACN Series
Activated Carbon Absorbers remove vapors
and odors.
• 10 scfm to 16,500 scfm
• 230psigmax.workingpressure
for threaded filters
• 150psigmax.workingpressure
for flanged filters
• Aluminumhousing(1⁄2”to3”NPT)
• Steelhousing(3”to12”FLG)
MOISTURE SEPARATORS
• 20to1500scfm,230psig
• Aluminumhousing(1⁄4”to3”NPT)
OVER & UNDER
COALESCER/ABSORBER
COMBINATION
• 10to50scfm/230psig
• Two-in-onedesign
PORTABLE AIR SYSTEMS
FOR PAINT OR SANDBLAST
APPLICATIONS
• 15cfmtwo-portmanifold
• 30scfm,four-portmanifold
• 230psigmax.workingpressure
• Floorstandorwallmountingbrackets
• Airpressureregulator
• Airpressuregauge
• Availableairheater
HIGH-TEMPERATURE DUST FILTER
• +450°F/150psig
• 15to1600scfm
Quincy filters protect pneumatic equipment
and processes from the harmful effects of con-
taminated compressed air by removing dirty
water, burnt oil and solid pollutants before
they can do any damage. Clean compressed air
will result in improved production and reduced
operating costs. World class, state-of-the-art
material and design make Quincy compressed
air filters the standard to which all others must
be compared.
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 2
an EnPro Industries company
ELEMENT CONSTRUCTION
Push-to-Fit Design — Aluminum Filters
• Easyelementreplacement
• Fitintegrityeliminatesleaks,
saving energy
Stainless Steel Support Core
• Providesstrength
• Eliminatescorrosion
• Protectselementfrombursting
under high differential pressure
1st Stage Pre-Filtration Support Layer
• Captureslargercontaminants
• Protects2ndStagefiltrationmedia
• Extendsservicelife
Multiwrap 2nd Stage
• Highvoidvolumeminimizes
pressure drop, saving energy
• Increasedsurfaceareaensures
maximum contaminant retention
• Extended life construction
• Deepbedprovidesoptimum
coalescing efficiency
• Selectedmediacombinations
provide precise filtration solutions
3rd Stage Interceptor Layer
• Providesadditionalstrength
• Optimizesinterceptionprocess
4th Stage Outer Stainless Steel Support
• Ensures total element integrity
Inside to Out Flow
• Prolongselementlifeand
improves drain performance
Polyester Needle Felt Drainage Layer
• Optimumoilremoval
• Hightemperaturetolerance
• Maximumdurability
• Willnotdisintegrate
• Suitableforusewithmineral
and synthetic oils
• Tolerantinaggressiveenvironments
Glass-Filled Nylon End Caps
• Color-codedforsimpleelement
grade identification
• Easyelementreplacement
• Willnotcorrode
Quincy’s Layered Multiwrap design employs a specially
blended borosilicate glass microfiber media to produce
strong, durable and efficient filter elements. The filtration
media combines high flow rates and high dirt-holding capaci-
ties without compromising element service life. Easy to iden-
tify and easy to install, these highly advanced products offer
the best performance available.
ELEMENTS
3
COMPRESSED AIR FILTERS
STANDARD LINE: PARTICULATE – COALESCER – ABSORBER
Quincy’s Standard Filtration lineup consists of
the three most common types of filters used in
compressed air systems. Aluminum housings
with threaded NPT connections are used for
flows up to 1530 cfm and steel housings with
flanged connections are used for flows up to
16,500 cfm.
• Push-to-fitdesignusedonthreadedfiltersforeasyfilterele-
ment replacement
• Multiwrapelementconstructionensuresoptimumperformance
• Modulardesignsavesenergyandallowsforeasyinstallation
of multiple threaded filters
• Aluminumhousingsfeatureelectrophoreticcoatingtoprevent
corrosion
• 10-yearhousingguaranteeonaluminumhousings
• Standardpressuredifferentialindicatoron
aluminum housings
• Standardautomaticcondensatedrainon
aluminum housings
STEEL HOUSINGS, FLANGED CONNECTIONS 1500 TO 16,000 CFM SERIES DCNF, CSNF, CPNF, CXNF AND ACNF
ACNT SERIES
Activated Carbon Absorber
designed to remove vapors
and odors. Installed imme-
datelydownstreamofeithera
CPNT or a CXNT coalescer,
itwillreduceoilcarry-
over to .003 ppm.
• Samefiltrationgradeasaluminumfilters
• Identifiedwithan“F”suffix
• UstampedfortheUSAandCRNapprovedforCanada
• Housingsarefreestandingandtoploadingforeasyelementreplacement
• Allgradesoffilterelementendcapsaremolded,providingstrength,
durability and long life
ALUMINUM HOUSINGS, THREADED CONNECTIONS 10 TO 1530 CFM
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 4
DCNT SERIES
Designed to remove high
concentrations of solids,
burntoilandbulkliquids
DCNT 5 micron, 5 ppm
CSNT, CPNT, CXNT SERIES
Designed to coalesce various
levels of liquid aerosols. The 1
micron CSN is also an ideal afte
filter for desiccant dryers.
CSNT 1 micron, 0.1 ppm
CPNT .01 micron, .01 ppm
CXNT .01 micron, .001 ppm
an EnPro Industries company
STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA
Grade10 1⁄4 10 17 GradeE10 1 3 11⁄2 8 3 1.43 0.65 72 35 210 75Grade20 1⁄4 20 33 GradeE20 1 3 11⁄2 8 3 1.43 0.65 72 35 210 75Grade30 3⁄8 30 50 GradeE30 1 3 11⁄2 8 3 1.43 0.65 72 35 210 75Grade60 1⁄2 60 100 GradeE60 1 31⁄2 11⁄4 13 4 2.87 1.30 88 32 315 100Grade125 3⁄4 125 208 GradeE125 1 5 11⁄2 15 4 5.95 2.70 125 39 365 100Grade150 1 150 250 GradeE150 1 5 11⁄2 15 4 5.95 2.70 125 39 365 100Grade200 1 200 333 GradeE200 1 5 11⁄2 21 6 7.72 3.50 125 39 515 150Grade300 11⁄4 300 500 GradeE300 1 5 11⁄2 21 6 7.72 3.50 125 39 515 150Grade425 11⁄2 425 708 GradeE425 1 51⁄2 2 22 6 9.70 4.40 135 50 545 150Grade500 2 500 833 GradeE500 1 51⁄2 2 22 6 9.70 4.40 135 50 545 150Grade650 2 650 1083 GradeE650 1 51⁄2 2 30 6 11.00 5.00 135 50 745 150Grade800 21⁄2 800 1333 GradeE800 1 8 23⁄4 32 8 25.40 11.50 200 68 805 200Grade1000 3 1000 1667 GradeE1000 1 8 23⁄4 32 8 25.40 11.50 200 68 805 200Grade1300 3 1300 2167 GradeE1300 1 8 23⁄4 37 8 34.20 15.50 200 68 925 200Grade1525 3 1525 2542 GradeE1525 1 9 21⁄2 42 12 41.90 19.00 230 65 1050 300
Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Complete Filter Assemblies
DCNE 3 4 5 5.0 5.0 248 120 1 40 1 75 6 400 232 16 GreenCSNE 2 2 1 0.1 0.1 248 120 1 75 2 150 6 400 232 16 RedCPNE 1 1 0.01 0.01 0.01 248 120 2 100 4 300 6 400 232 16 BlueCXNE 1 1 0.01 0.001 0.001 248 120 2 140 5 350 6 400 232 16 BlackACNE 1 1 0.01 0.003 0.003 77 25 1 75 — — Min. every 6 months 232 16 Black
Max. Pressure Loss Max. Element Max. Particle Oil Carryover Max. Change Working End CapFilter Max. Particle Size Oil Content Class Removal at 68˚F at 20˚C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 ˚F ˚C psi mbar psi mbar psi mbar psig barg Code
Specs
Grade1503 3 1500 2550 Grade1500 1 58 15 48 10 165 74 1472 381 1219 254Grade1504 4 1500 2550 Grade1500 1 58 171⁄8 48 61⁄2 175 80 1473 435 1219 165Grade2004 4 2000 3400 Grade2000 1 58 213⁄8 481⁄4 13 320 145 1473 543 1226 330Grade2006 6 2000 3400 Grade2000 1 591⁄4 251⁄2 48 71⁄2 360 163 1505 648 1219 191Grade3004 4 3000 5100 Grade3000 1 72 213⁄8 621⁄4 13 385 175 1829 543 1581 330Grade3006 6 3000 5100 Grade3000 1 751⁄4 25.5 64 71⁄2 420 191 1911 648 1626 191Grade4506 6 4500 7650 Grade1500 3 831⁄2 251⁄4 681⁄2 231⁄2 580 263 2121 641 1740 597Grade6008 8 6000 10200 Grade1500 4 863⁄4 25 68 23 650 295 2203 635 1727 584Grade10510 10 10500 17850 Grade1500 7 100 31 80 30 800 363 2540 787 2032 762Grade16512 12 16500 28050 Grade1500 11 1133⁄4 441⁄2 87 16 1000 454 2889 1130 2210 406
Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Steel Housings — Flanged
Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51
Formaximumflowrate,multiplymodelflowrateshownintheabovetablebythecorrectionfactorcorrespondingtotheworkingpressure.
Correction Factor
Model Grades 10, 20 & 30 Model Grades 60–1525
Model Grades 1503, 1504 & 2004
A
C
D
B
Model Grades 2006–16512
B
A
C
D
5
COMPRESSED AIR FILTERS
HIGH TEMPERATURE:1 MICRON DUST FILTERS,450˚F, 150 PSIG
• Featuresahigh-temperaturedustfilter
withheavy-dutybowl
• Ribbedbowlfacilitatesremovalwhen
changing elements
NOTE:Alloyfiltersshippedloosewillhaveaspecial
high-temperatureblackpowdercoatpaint.
• DesignedspecificallyforHeatReactivatedDesiccantAirDryers
• Nomexouterlayerisprovidedforhigh-temperatureoperation
• Push-to-fitdesignusedonthreadedfiltersforeasyfilterelementreplacement
• Multiwrapelementconstructionprovidesoptimumperformance
ALUMINUM HOUSINGS, THREADED NPT CONNECTIONS 15 TO 650 CFM, SERIES HTDT
• Samefiltrationgradeasaluminumfilters
• Identifiedwithan“F”suffix
• UstampedfortheUSAandCRNapproved
for Canada
• Housingsarefreestandingandtop-loading
for easy element replacement
• Allgradesoffilterelementendcapsare
molded, providing strength, durability
and long life
STEEL HOUSINGS, FLANGED CONNECTIONS 1500 TO 16,000 CFM, SERIES HTDF
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 6
an EnPro Industries company
HIGH TEMPERATURE — SPECIFICATIONS & ENGINEERING DATA
HTDT15 1⁄4 15 25 HTDE15 1 21⁄2 1⁄2 6 2 0.5 0.25 63 15 150 50HTDT30 3⁄8 30 50 HTDE30 1 21⁄2 1⁄2 71⁄2 2 0.6 0.27 63 15 190 50HTDT65 1⁄2 65 108 HTDE65 1 41⁄2 11⁄2 12 6 5.7 2.60 114 38 305 150HTDT75 3⁄4 75 125 HTDE75 1 41⁄2 11⁄2 12 6 5.7 2.60 114 38 305 150HTDT150 1 150 250 HTDE150 1 41⁄2 11⁄2 151⁄2 6 7.3 3.30 114 38 395 150HTDT300 11⁄2 300 500 HTDE300 1 53⁄4 2 21 7 16.5 7.50 146 50 435 170HTDT450 2 450 750 HTDE450 1 53⁄4 2 21 7 16.5 7.50 146 50 435 170HTDT650 2 650 1084 HTDE650 1 53⁄4 2 25 7 22.0 10.00 146 50 635 170
Metric Element Number Dimensions Dimensions Filter Pipe Size Flow Rate Model of A B C D Weight A B C D Model NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Dust Filters — Threaded
HTDF1503 3 1500 2550 HTDE1500 1 58 15 48 10 165 74 1473 381 1219 254HTDF1504 4 1500 2550 HTDE1500 1 58 171⁄8 48 61⁄2 175 80 1473 435 1219 165HTDF2004 4 2000 3400 HTDE2000 1 58 213⁄8 481⁄4 13 320 145 1473 543 1226 330HTDF2006 6 2000 3400 HTDE2000 1 591⁄4 25.5 48 71⁄2 360 163 1505 648 1219 191HTDF3004 4 3000 5100 HTDE3000 1 72 213⁄8 621⁄4 13 385 175 1829 543 1581 330HTDF3006 6 3000 5100 HTDE3000 1 751⁄4 251⁄2 64 71⁄2 420 191 1911 648 1626 191HTDF4506 6 4500 7650 HTDE1500 3 831⁄2 251⁄4 681⁄2 231⁄2 580 263 2121 641 1740 597HTDF6008 8 6000 10200 HTDE1500 4 863⁄4 25 68 23 650 295 2203 635 1727 584HTDF10510 10 10500 17850 HTDE1500 7 100 31 80 30 800 363 2540 787 2032 762HTDF16512 12 16500 28050 HTDE1500 11 1133⁄4 441⁄2 87 16 1000 454 2889 1130 2210 406
Metric Element Number Dimensions Dimensions Filter Pipe Size Flow Rate Model of A B C D Weight A B C D Model Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Dust Filters — Flanged
High-temperature dust filter element gradeHTDE 1 2 2 450 250 1.1 75 NA NA 6 400 150 10 BrickRed
Max. Pressure Loss Max. Element Particle Oil Carryover Max. Change Working End CapFilter Removal at 68˚F at 20˚C Temperature Clean & Dry Wet Element Pressure ColorElement in Microns ppm mg/m3 ˚F ˚C psi mbar psi mbar psi mbar psig barg Code
Specs
Models HTDT 15 & 30
Models HTDT 65–650
Operating psig 145 290 435 580 725 Pressure barg 10 20 30 40 50 Correction Factor 0.34 0.57 0.71 0.86 1.0
Formaximumflowrate,multiplymodelflowrate shownintheabovetablebythecorrectionfactor correspondingtotheworkingpressure.
Correction Factor
Models HTDF 1503, 1504 and 2004
A
C
D
B
Models HTDF 2006–16512
B
A
C
D
7
PORTABLE AIR SYSTEMS
15 TO 30 CFM
Quincy Portable Air Packages are complete
systems designed to provide, clean, odor-
free, taste-free, particle and liquid oil-free
compressed air for sand blasting and/or paint-
ing hoods. The 15-cfm system has two outlet
ports and can accommodate two sets. The
30-cfm package has four outlet ports and can
accommodate four sets. The system provides
absolute filtration down to 0.01 micron and
oil removal down to 0.003 ppm.
The System Includes:
• Aluminumhousingswithelectrophoretic
coating to prevent corrosion
• WSNTmoistureseparator
• CSNT1micron,0.1ppmCoalescer
• QUDTwithCPNT0.01micron,0.01ppm
and .003 ppm activated carbon absorber
The System includes:
• CombinationCoalescerandActivatedCarbonAbsorber
• Twofunctionsinoneunit
• Space-savingOver&Underconfiguration
• Push-to-fitdesignforeasyfilterelementreplacement
• Multiwrapelementconstructionensuresoptimumperformance
• Non-shedding,high-speedcarbongranulesincreasevapor-holdingcapacity
• Aluminumhousingswithelectrophoreticcoatingtopreventcorrosion
• Standardpressuredifferentialindicator
• Standardautomaticcondensatedrain
Using a unique two-sided head, Quincy’s Over & Under Duplex filter
combines a CPN Series (0.01-micron, 0.01-ppm) coalescer with an
ACN Series (.003-ppm) activated carbon absorber. This compact, two-
stage, single-piece filtration system saves space, is easy to install and
delivers ISO 8573.1 class 1 compressed air. The Over & Under is ideal
for food and beverage, instrumentation and pharmaceutical applications.
OVER & UNDER DUPLEX
10 TO 50 CFM, SERIES OUDT
COMPRESSED AIR FILTERS
• Push-to-fitdesign
• PNF drain layer
• Color-codedendcaps
• Pressuredifferentialindicator
• Multiwrapconstruction
• Airpressureregulatorandgauge
• Activatedcarbonelementimpregnated
withreddyeoilindicator
• Compressedairheateroption
• Wallmountingorfloor-mounting
configuration
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 8
an EnPro Industries company
WARNING: The Portable air systems described in this brochure willnotremovecertaintypesofgases,includingCarbonMon-oxide (CO)andCarbonDioxide (CO2). These Air Systems are designed to offer the user protection in potentially harmful environments. It is therefore imperative the products be cor-
rectly installed and properly controlled by a competent person. Properly controlled means the equipment installed should be fullycheckedpriortoeveryuse.Shouldanyfaultbediscovered,it must be repaired or the failed component replaced to guaran-teefullworkingorderbeforeuse.
Wallmounted Portable Air PackagesBWST15 1⁄4 2 15 25 BAEK 15 1 Kit 101⁄4 123⁄4 123⁄4 3 0.50 0.25 280 360 323 77BWHT15 1⁄4 2 15 25 BAEK 15 1 Kit 153⁄4 18 131⁄4 4 0.60 0.27 418 498 337 100BWST30 3⁄8 2 15 25 BAEK 30 1 Kit 101⁄4 123⁄4 123⁄4 3 5.70 2.60 280 360 323 77BWHT30 3⁄8 2 15 25 BAEK 30 1 Kit 153⁄4 18 131⁄4 4 5.70 2.60 418 498 337 100
Frame-Mounted Portable Air PackagesBFST 15 1⁄4 4 30 50 BAEK 15 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500BFHT15 1⁄4 4 30 50 BAEK 15 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500BFST 30 3⁄8 4 30 50 BAEK 30 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500BFHT30 3⁄8 4 30 50 BAEK 30 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500
Metric Pipe Air Element Number Dimensions Dimensions Filter Size Outlet Flow Rate Model of A B C D Weight A B C D Model NPT Ports scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Portable Air Packages
Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1.0 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51
Formaximumflowrate,multiplymodelflowrateshownintheabovetablebythecorrectionfactorcorrespondingtotheworkingpressure.
Correction Factor
Portable Air Package KitBAEK 1 1 >0.01 >0.003 >0.003 77 25 3.7 250 6.6 950 Min. every 6 months 145 10 Red/Blue/Black
Duplex Filter Kit (OUDK)CPNE 1 1 0.01 0.01 0.01 248 120 2.2 150 4.4 300 6 400 232 16 BlueACDE 1 1 0.01 0.003 0.003 77 25 1.1 75 NA NA Min. every 6 months 232 16 Black
Max. Pressure Loss Max. Element Max. Particle Oil Carryover Max. Change Working End CapFilter Max. Particle Size Oil Content Class Removal at 68˚F at 20˚C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 ˚F ˚C psi mbar psi mbar psi mbar psig barg Code
Specs
OUDT10 1⁄4 10 17 OUDK10 1Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT15 1⁄4 15 25 OUDK15 1Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT30 3⁄8 30 50 OUDK30 1Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT50 1⁄2 50 83 OUDK50 1Kit 31⁄2 8 9 4 2.75 1.25 90 200 225 100
Metric Element Number Dimensions Dimensions Filter Pipe Size Flow Rate Model of A B C D Weight A B C D Model NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Over & Under Duplex
Models BWST 15 & 30
Models BFST 15 & 30
Models OUDT 10–50
PORTABLE AIR, OVER & UNDER DUPLEX — SPECIFICATIONS & ENGINEERING DATA
9
COMPRESSED AIR FILTERS
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 10
MECHANICAL MOISTURE SEPARATORS
20 TO 1500 CFM, 230 PSIG, SERIES WSNT
Quincy Mechanical Moisture Separators are
designed to remove bulk liquids and large
volumes of water. They are typically installed
downstream of aftercoolers, air receivers, refrig-
erated air dryers and at strategic points of use
throughout the compressed air distribution
system. The design employs an internal spin-
ner to create a centrifugal action that effectively
removes large quantities of water.
• Largesumpandquietzonetopreventmoisture
re-entrainment
• Modulardesignallowsforeasyinstallation
of multiple housings and saves energy
• AnnularsealandcaptiveO–ringpreventleaks
• Aluminumhousings(1⁄4”to3NPT)feature
electrophoretic coating to prevent corrosion
• Aluminumhousings(1⁄4”to3”NPT)carry
a 10-year housing guarantee
• Standardautomaticcondensatedrain
Metric Dimensions Dimensions Filter Pipe Size Flow Rate A B C D Weight A B C D Model NPT scfm Nm3/hr In. In. In. In. lb. kg. mm mm mm mm
Moisture Separators
Operating psig 4 9 15 29 44 58 72 87 100 Pressure barg 0.3 0.6 1 2 3 4 5 6 7 Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1
Operating psig 115 130 145 160 174 189 203 218 232 Pressure barg 8 9 10 11 12 13 14 15 16 Correction Factor 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51
Formaximumflowrate,multiplymodelflowrateshownintheabovetablebythecorrectionfactorcorrespondingtotheworkingpressure.
Correction Factor
WSNT 248 120 35 1.5 0.7 50 232 16
Max. Min. Typical Max. Recommended Recommended Pressure Loss WorkingFilter Operating Temp. Operating Temp. At Rated Flow PressureModel ˚F ˚C ˚F ˚C psi mbar psig barg
Specs
SPECIFICATIONS & ENGINEERING DATA
WSNT20 1⁄4 20 35 3 11⁄4 81⁄4 3 1.45 0.65 72 35 210 75WSNT30 3⁄8 30 50 3 11⁄4 81⁄4 3 1.45 0.65 72 35 210 75WSNT63 1⁄2 63 112 31⁄2 11⁄4 81⁄4 4 2.90 1.30 88 32 210 100WSNT127 3⁄4 127 216 5 11⁄2 12 4 5.95 2.70 125 39 300 100WSNT176 1 176 300 5 11⁄2 12 4 5.95 2.70 125 39 300 100WSNT318 11⁄4 318 540 5 11⁄2 12 4 5.95 2.70 125 39 300 100WSNT427 11⁄2 427 725 51⁄2 2 19 6 9.70 4.40 135 50 480 150WSNT675 2 675 1150 51⁄2 2 19 6 9.70 4.40 135 50 480 150WSNT1000 21⁄2 1000 1700 8 23⁄4 24 8 25.5 11.5 200 68 590 200WSNT1500 3 1500 2550 8 23⁄4 24 8 25.5 11.5 200 68 590 200
an EnPro Industries company
11
HIGH-PRESSURE
ALUMINUM FILTERS
Coalescer — Absorber
Quincy’s aluminum alloy, 750 psig high pressure filter
lineup offers an economic alternative to the high cost of
stainless steel. There are two levels of coalescing and an
activated carbon absorber. Ideally suited for the PET
bottle blowing industry, the coalescers remove various
levels of liquid aerosols and the activated carbon absorb-
er removes vapor and odors.
• High-temperaturecapacity(250ûF.)
• Multiwrapelementconstructionfor
optimum performance and long life
• Syntheticlubricantandmineraloil
compatibility
• Largesumpandquietzonetoprevent
re-entrainment
• Push-to-fitdesignforeasyfilter
element replacement
• Modulardesignallowsforeasyinstallationof
multiple filters and saves energy
750 psig/250°F150 to 3000 scfm (1/2”to2”NPT)
• HSCTstandardcoalescer
• HPCTpolishingcoalescer
• HACTactivatedcarbon
HIGH-PRESSURE
STAINLESS STEEL FILTERS
Coalescer — Absorber
Quincy’s line of 316 grade Stainless Steel filters
for pressure requirements of 750 psig through
5000 psig feature:
• Three pressure ranges
(750 psig, 1,500 psig, 5,000 psig)
• Heavy-duty,StainlessSteeltierod
design for 1500 psig and 5000 psig
750 psig/250°F
60 to 2000 scfm (1/2”to2”NPT)
• SSCTstandardcoalescer
• SPCTpolishingcoalescer
• SACTactivatedcarbon
1500 psig/250°F
65 to 2050 scfm (1/2”to2”NPT)
• ESCTstandardcoalescer
• EPCTpolishingcoalescer
• EACTactivatedcarbon
5000 psig/250°F28 to 775 scfm (1/2”to11/2”NPT)
• VSCTstandardcoalescer
• VPCTpolishingcoalescer
• VACTactivatedcarbon
COMPRESSED AIR F ILTERS
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 12
HIGH PRESSURE, 750 PSIG — SPECIFICATIONS & ENGINEERING DATA
H__T94 1/4 94 160 H__E94 1 21/2 1/2 6 2 0.5 0.25 63 15 150 50H__T147 3/8 147 250 H__E147 1 21/2 1/2 71/2 2 0.6 0.27 63 15 190 50H__T265 1/2 265 450 H__E265 1 41/2 11/2 12 6 5.7 2.60 114 38 305 150H__T324 3/4 324 550 H__E324 1 41/2 11/2 12 6 5.7 2.60 114 38 305 150H__T492 1 492 835 H__E492 1 41/2 11/2 151/2 6 7.3 3.30 114 38 395 150H__T1015 11/2 1015 1725 H__E1015 1 53/4 2 21 7 16.5 7.50 146 50 435 170H__T1132 2 1132 1925 H__E1132 1 53/4 2 21 7 16.5 7.50 146 50 435 170H__T1882 2 1882 3200 H__E1882 1 53/4 2 25 7 22.0 10.00 146 50 635 170
Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Aluminum, 750 psig
S__T60 1/4 60 100 S__E60 1 31/2 3/4 7 3 3.80 1.70 85 18 170 75S__T120 3/8 120 200 S__E120 1 31/2 3/4 8 4 4.40 2.00 85 18 205 100S__T200 1/2 200 340 S__E200 1 31/2 3/4 10 4 4.90 2.20 85 18 255 100S__T300 3/4 300 500 S__E300 1 41/2 11/4 11 6 8.80 4.00 110 27 270 150S__T600 1 600 1000 S__E600 1 41/2 11/4 17 12 11.0 5.00 110 27 420 300S__T1000 11/2 1000 1700 S__E1000 1 6 13/4 21 12 33.0 15.0 150 45 525 300S__T1200 2 1200 2040 S__E1200 1 6 13/4 21 12 33.0 15.0 150 45 525 300S__T2000 2 2000 3400 S__E2000 1 6 13/4 33 20 46.0 21.0 150 45 825 500
Stainless Steel, 750 psig
Models HPAT 94 & 147
Models HPST 60–2000
Models HPAT 265–1882
High-pressure aluminum filter element grades, 750 psigHSCE 1 0.1 0.1 248 120 1.1 75 2.2 150 6 400 750 50 BlackHPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 6 400 750 50 BlackHACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 750 50 Black
High-pressure stainless steel filter element grades, 750 psigSSCE 1 0.1 0.1 248 120 1.1 75 2.2 150 10 700 750 50 BlackSPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 10 700 750 50 BlackSACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 750 50 Black
Max. Pressure Loss Max. Element Particle Oil Carryover Max. Change Working End CapFilter Removal at 68°F at 20°C Temperature Clean & Dry Wet Element Pressure ColorElement in Microns ppm mg/m3 °F °C psi mbar psi mbar psi mbar psig barg Code
Specs
Operating psig 145 290 435 580 725 Pressure barg 10 20 30 40 50 Correction Factor 0.34 0.57 0.71 0.86 1.0
For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.
Correction Factor for Aluminum Correction Factor for Stainless Steel
Operating psig 58 87 116 145 220 290 435 580 725 Pressure barg 4 6 8 10 15 20 30 40 50 Correction Factor 0.14 0.22 0.28 0.34 0.47 0.56 0.70 0.85 1.0
Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
an EnPro Industries company
13
HIGH PRESSURE 1500 & 5000 PSIG — SPECIFICATIONS & ENGINEERING DATA
Metric Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Element Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Stainless Steel, 1500 & 5000 psig
Models HPST 65–775
High-pressure stainless steel filter element grades, 1500 psigESCE 1 0.1 0.1 248 120 1.1 75 2.2 150 6 400 1500 100 BlackEPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 6 400 1500 100 BlackEACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 1500 100 Black
High-pressure stainless steel filter element grades, 5000 psigVSCE 1 0.1 0.1 248 120 1.1 75 2.2 150 10 700 5000 350 BlackVPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 10 700 5000 350 BlackVACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 5000 350 Black
Max. Pressure Loss Max. Element Particle Oil Carryover Max. Change Working End CapFilter Removal at 68°F at 20°C Temperature Clean & Dry Wet Element Pressure ColorElement in Microns ppm mg/m3 °F °C psi mbar psi mbar psi mbar psig barg Code
Specs
Operating psig 290 435 580 725 870 1015 1160 1300 1500 Pressure barg 20 30 40 50 60 70 80 90 100 Correction Factor 0.45 0.57 0.68 0.80 0.84 0.88 0.92 0.96 1.0
For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.
Correction Factor for Stainless Steel, 1500 psig
Correction Factor for Stainless Steel, 5000 psig
High-pressure stainless steel filter element grades, 1500 psigE__T65 1/4 65 110 E__E65 1 23/4 3/4 6 3 7.10 3.20 65 20 135 70E__T185 3/8 185 315 E__E185 1 23/4 3/4 10 7 12.3 5.60 65 20 250 180
E__T270 1/2 270 460 E__E270 1 31/2 3/4 11 10 13.5 6.10 88 20 275 250E__T400 3/4 400 680 E__E400 1 51/8 1 11 6 23.2 10.5 132 26 265 150E__T700 1 700 1200 E__E700 1 51/8 1 19 12 32.4 14.7 132 26 480 300E__T1050 11/2 1050 1785 E__E1050 1 6 13/4 21 12 48.5 22.0 150 45 525 300E__T2050 2 2050 3485 E__E2050 1 6 13/4 33 20 61.7 28.0 150 45 825 500
High-pressure stainless steel filter element grades, 5000 psigV__T28 1/4 28 48 V__E28 1 13/4 1/2 4 3 3.50 1.60 41 10 103 60V__T67 3/8 67 111 V__E67 1 23/4 3/4 6 3 7.10 3.20 65 20 135 70 V__T150 1/2 150 255 V__E150 1 31/2 3/4 9 6 12.3 5.60 88 20 210 150V__T310 3/4 310 520 V__E310 1 31/2 1 11 10 13.5 6.10 88 25 280 250V__T445 1 445 750 V__E445 1 6 11/2 13 8 32.0 14.5 150 35 330 200V__T775 11/2 775 1330 V__E775 1 6 11/2 19 12 38.4 17.4 150 35 180 300
Operating psig 725 1450 2175 2900 3625 4350 5000 Pressure barg 50 100 150 200 250 300 350 Correction Factor 0.73 0.78 0.82 0.87 0.91 0.96 1.0
MIST ELIMINATOR - HIGH EFFICIENCY
HEAVY-DUTY COALESCING FILTER
• Lowerpressuredropcomparedtocon-ventional coalescing and particulate filters (average1psigversus6psig).Higherpressure drops require the compressor to operate at an elevated pressure, there-forerequiringmorepower.Every2psigreduction in pressure saves approximately 1%aircompressorpowerbasedon100psig operating pressure. Since the Quincy Mist Eliminator does not require prefil-ters or particulate filters, you could easily save in excess of $3,000 per year in air compressor electrical energy (based on 8,000 hours per year operation, $0.07 per Kwhour,100hpcompressoranda93%motor efficiency).
• Largetankvolumecapturesandretainsinadvertent lubricant discharge caused by compressor separation system malfunc-tion,whichprotectsdownstreamequip-ment.
• Average element life of 10 years versus 6 months for conventional coalescing and particulate filter elements reduces main-tenanceandwastedisposal.
The Quincy Mist Eliminator is a heavy-duty
coalescing type filter engineered to efficiently
remove oil, particulate, and water from com-
pressed air. By using a combination of impac-
tion, interception and Brownian Movement, the
Quincy Mist Eliminator achieves 100% effi-
ciency in removing particles 3 micron and larger,
99.98% of 0.1 micron and larger and 99.5% of
0.01 micron and larger. Typical pressure drop
is less than 1 psig. Average element life in con-
tinuous service is 10 years.
A 10-year element life can be achieved in rela-
tively clean environments.
LONG LIFE AND LOW PRESSURE DROP
Calibrated Differential Pressure Gauge is standard equipment
COMPRESSED AIR FILTERS
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 14
A Pneumatic No-Loss Demand Drain is optional
equipment
an EnPro Industries company
15
Compressed air enters the Quincy Mist
Eliminator through the inlet connection on the
top of the tank (see Figure 1) where it is even-
ly distributed throughout the large surface
area of the filter element due to low velocities.
Aerosols and particulate are filtered out and
accumulate in the bottom of the tank, where
they can be removed by an optional Demand
Drain. Clean air then exits through the outlet
connection.
Figure 2
Air in
Air out
Drain
Figure 1
ME — SPECIFICATIONS & ENGINEERING DATA
Mist Eliminator Min. Filter In/Out Dimensions Removal Flanged Drain scfm @ Max Diameter Height Clearance* Approx Connections ConnectionsModel 100 psig psig In. In. In. Wt. lb. In. In.
ME 250S 250 150 14 451/8 22 471 11/2 1 NPTME 500S 500 150 14 581/8 35 518 2 1 NPTME 800S 800 150 14 731/4 50 586 21/2 1 NPTME 1100S 1100 150 16 781/2 551/8 664 3 1 NPTME 1500TP 1500 150 18 697/8 453/8 805 4 1 NPTME 1900TP 1900 150 18 747/8 503/8 965 4 1 NPTME 2500TP 2500 150 18 867/8 623/8 860 5 1 NPTME 3500TP 3500 150 24 8611/16 597/8 1400 5 1 NPTME 4500TP 4500 150 24 993/4 727/8 1517 6 1 NPTME 5000TP 5000 150 24 1053/4 787/8 1564 6 1 NPTME 6000TP 6000 150 24 1207/8 937/8 1726 8 1 NPTME 7000TP 7000 150 30 1083/8 801/8 2450 8 11/2 NPTME 8000TP 8000 150 30 1163/8 881/8 2520 8 11/2 NPTME 9000TP 9000 150 30 1243/8 961/8 2603 8 11/2 NPTME 10000TP 10000 150 36 1183/16 885/8 3640 10 11/2 NPTME 15000TP 15000 150 42 13211/16 1007/8 CF 10 11/2 NPT
Notes:LargerSizesAvailableConsultFactory. *DoesNotIncludeRigging.
1,500 cfm through 15,000 cfm models utilize
a space-saving double element design (see
Figure 2). Using a double nesting tech-
nique, the Quincy Mist Eliminator offers high
efficiency separation in a low profile package.
By nesting an element inside an element, total
surface area is greater than conventional single
element designs. Due to reduced overall height,
the Quincy Mist Eliminator can be installed in
locations where conventional single element
designs cannot. For example, a 10,000 cfm
Quincy Mist Eliminator low profile design
is only 118 inches tall. Compare this to other
single element designs that are 210 inches tall.
That’s a reduction of over 7 feet in overall
height! Imagine the savings in time and con-
venience when you change the element or
service the unit.
All Quincy Mist Eliminator tanks are ASME
coded and stamped. Standard equipment
includes a calibrated differential pressure
gauge and enamel paint. No Loss Demand
Drains are optional. Pressure relief valves are
not included but may be required by local
codes.
HOW THE QUINCY MIST ELIMINATOR WORKS
UNIQUE DOUBLE ELEMENT DESIGN
quincycompressor.com
QPNC-500quincycompressor.com
QDHT-1000quincycompressor.com
Air Quality ClassificationISO 8573.1
WSNBulk
LiquidDP1
Quincy Rotary Screw Wet Receiver
1gal/CFMand/or
MistEliminator
DP2
Dry Receiver
5gal/CFM
CSN1 Micron0.1 PPM
DP3
CPN0.01 Micron0.01 PPM
DP5ACN
0.003 PPMVapor & Odors
SolidsMicron ISO PDP ISO PPM ISO
0.01 1 +38˚F 4 0.01 1 10.7 738
0.01 1 +38˚F 4 0.003 1 11.8 814
1 2 -40˚F 2 0.01 1 9.2 634
0.01 1 -40˚F 2 0.003 1 10.3 710
1 2 +50˚F 6 0.01 2 7.8 538
0.01 1 +50˚F 6 0.003 1 10.0 689
1 2 -40˚F 2 0.01 1 9.2 634
0.01 1 -100˚F 1 0.001 1 14.2 979
Moisture Oilpsi Mbar
Refrigerated Air DryerQPNC Non-Cycling
QPCD CyclingDP4
WetSystemAvg. DP
Quincy Reciprocating AC
WSN Moisture Separator
DCN Particulate/Coarse Coalescer
CSN STD 0.1 PPM Coalescer, 1 Micron
CPN Polishing 0.01 PPM Coalescer
CXN Xtra 0.001 PPM Coalescer
ACN Activated Carbon Absorber
OUD Over + Under Duplex
HTD High Temperature, 1 Micron
QPNC Non-Cycling Refrigerated Dryer
QPCD Cycling Refrigerated Dryer
QDTS Small Heatless Dryer
QDTH Industrial Heatless Dryer
QDHP Heated Purge Dryer
QDBP Blower Purge Dryer
QPHT High Temp. Refrigerated Dryer
AC After Cooler
DP Drain Point
WSNBulk
LiquidDP6
Dry Receiver
5gal/CFM
CPN0.01 Micron0.01 PPM
DP7
CSN (NPT)HTD (FLG)1 Micron
Particulate
ACN0.003 PPMVapor & Odors
0.01 1 -40˚F 2 0.003 1 10.3 710
ACN0.003 PPMVapor & Odors
Desiccant Heatless Air DryerQDTS—Small
QDTH—Industrial-40˚F PDP
QuincyCondensate
Purifier
CSN1 Micron0.1 PPM
DP11 CPN0.01 Micron0.01 PPM
ACN0.003 Micron
OUD
High Temperature/Refrigerated Air DryerQPHT—High Temp.
DP10
Dry Receiver
5gal/CFM
CPN0.01 Micron0.01 PPM
DP8
Desiccant Heated Air DryerQDHP—Heated PurgeQDBP—Blower Purge
-40˚F PDP
QDHP-1000quincycompressor.com
Approximate Liquid Removal100 CFM, 100 psi, 80˚F, 4000 hrs./yr., 2 PPM
DrainPoint
1234
300020003051300
Gallonsper Year
DrainPoint
5678
1403000310310
Gallonsper Year
DrainPoint
91011
3004320120
Gallonsper Year
QPHT-40quincycompressor.com
NOTE: Requires CXN (.001 PPM) filter in series with standard CPN prefilter.
CSN1 Micron
Particulate
QSI-500iquincycompressor.com
DCN5 Micron5 PPMDP9
an EnPro Industries company
an EnPro Industries company
701 North Dobson Avenue | Bay Minette, AL 36507 | Phone 251.937.5900 | Fax 251.937.7182 | Email: [email protected]
©2009 Quincy Compressor an EnPro Industries company All rights reserved. Printed in U.S.A. (QATF-004 03/09)
COMPRESSED AIR SYSTEMS BEST PRACTICE