AMERICAN STANDARD page 1 of 2 ACACIA E BACK TO WALL PAN SPECIFICATIONS Recommended use Domestic Hotel & Commercial Material Vitreous China Weight Rim configuration Rimless Bowl configuration P Trap (converts to S using plastic s-bend provided) Pan fixing Cistern requirement Seat Soft Close Quick Release Seat 31kg Set out P Trap 190 mm. fixed Screwed to floor using brackets provided and For use with in wall cistern or flush valve (ordered separately) Silicone into Place S Trap 80 - 95 mm. (recommend 80 mm.) To see the complete AMERICAN STANDARD range go to www.reece.com.au/bathrooms Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and setouts listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 1 CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions. TM WMKA21024 AS 1172.1 The more stars the more water efficient 3.5 litres average flush 4.5 L per full flush / 3 L per half flush In accordance with AS/NZS 6400 Licence No. 0050 LIXIL (Thailand) Public Company Limited Oct 2017 M31887 Rev.02 ***Dimensions are nominal measurements only.

AMERICAN STANDARD ACACIA E BACK TO WALL PAN · ACACIA E BACK TO WALL PAN SPECIFICATIONS Recommended use Domestic Hotel & Commercial Material Vitreous China Weight Rim configuration

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AMERICAN STANDARD ACACIA E BACK TO WALL PAN · ACACIA E BACK TO WALL PAN SPECIFICATIONS Recommended use Domestic Hotel & Commercial Material Vitreous China Weight Rim configuration

AMERICAN STANDARDpage 1 of 2

ACACIA E BACK TO WALL PAN

SPECIFICATIONSRecommended use Domestic Hotel & Commercial

Material Vitreous China

Weight

Rim configuration Rimless

Bowl configuration P Trap (converts to S using plastic s-bend provided)

Pan fixing

Cistern requirement

Seat Soft Close Quick Release Seat

31kg

Set out P Trap 190 mm. fixed

Screwed to floor using brackets provided and

For use with in wall cistern or flush valve (ordered separately)

Silicone into Place

S Trap 80 - 95 mm. (recommend 80 mm.)

To see the complete AMERICAN STANDARD range go towww.reece.com.au/bathrooms

Disclaimer: Products in this speci�cation manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary speci�cations or delete models from their range without prior noti�cation. Dimensions are nominal measurements only. Dimensions and setouts listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.Tech Page Version 1

CLEANING RECOMMENDATIONSWe recommend the use of soapy water or approved cleaners.This product should not be cleaned with abrasive materials.Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions.

TM

WMKA21024AS 1172.1

The morestars the morewater efficient

3.5 litresaverage flush

4.5 L per full flush / 3 L per half flush

In accordance with AS/NZS 6400

Licence No. 0050LIXIL (Thailand) Public Company Limited

Oct 2017M31887 Rev.02

***Dimensions are nominal measurements only.

Page 2: AMERICAN STANDARD ACACIA E BACK TO WALL PAN · ACACIA E BACK TO WALL PAN SPECIFICATIONS Recommended use Domestic Hotel & Commercial Material Vitreous China Weight Rim configuration

CONNECTOR CUTOUT (B)

ROUGHING - IN (A)

80-85 mm.85-90 mm.

25 mm.30 mm.

90-95 mm. 35 mm.

INSTALLATION INSTRUCTIONS

10mm.

80 3 mm.

P trap installation

S trap installation

Finished floor

80-95 mm.

190mm.

Finished floor

Fini

shed

wal

l

Finished floor

Finis

hed

wall

Finished floor

Fini

shed

wal

l

5

7 8

6

AMERICAN STANDARDpage 2 of 2

ACACIA E BACK TO WALL PAN

190

B

A