52
*26733617_0620* Drive Technology \ Drive Automation \ System Integration \ Services Manual ALX0517 Application Module for MOVIFIT ® FC – Function Level "Technology" with PROFINET IO, EtherNet/IP™ or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN

ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

*26733617_0620*Drive Technology \ Drive Automation \ System Integration \ Services

Manual

ALX0517 Application Modulefor MOVIFIT® FC – Function Level "Technology" with PROFINET IO,EtherNet/IP™ or Modbus TCP Fieldbus Interface

Edition 06/2020 26733617/EN

Page 2: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

SEW-EURODRIVE—Driving the world

Page 3: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

Table of contents

Manual – ALX0517 Application Module 3

Table of contents1 General information..................................................................................................................   5

1.1 About this documentation ............................................................................................... 51.2 Content of the documentation......................................................................................... 51.3 Applicable documentation............................................................................................... 51.4 Structure of the warning notes ........................................................................................ 5

1.4.1 Meaning of signal words ................................................................................   51.4.2 Structure of section-related safety notes........................................................   61.4.3 Structure of embedded safety notes ..............................................................   6

1.5 Decimal separator in numerical values ........................................................................... 61.6 Rights to claim under limited warranty ............................................................................ 61.7 Terms and conditions of use........................................................................................... 61.8 Product names and trademarks...................................................................................... 71.9 Copyright notice .............................................................................................................. 71.10 Short designation ............................................................................................................ 7

2 Safety notes ..............................................................................................................................   82.1 Preliminary information ................................................................................................... 82.2 Target group ................................................................................................................... 82.3 Network security and access protection ......................................................................... 82.4 Designated use ............................................................................................................... 8

3 Project planning information...................................................................................................   93.1 Requirements.................................................................................................................. 93.2 PC and software ............................................................................................................. 93.3 Controller ........................................................................................................................ 93.4 Encoder........................................................................................................................... 9

4 System description ................................................................................................................   104.1 Area of application ........................................................................................................ 104.2 Overview of the system................................................................................................. 104.3 Profiles .......................................................................................................................... 11

5 Operating modes ....................................................................................................................   125.1 Jog mode ...................................................................................................................... 125.2 Referencing mode......................................................................................................... 125.3 Speed mode.................................................................................................................. 12

5.3.1 Speed mode without encoder ......................................................................   125.4 Positioning mode .......................................................................................................... 12

5.4.1 Positioning mode with EI7C incremental encoder........................................   125.4.2 Positioning mode with F5868 absolute encoder ..........................................   13

5.5 Prioritized fixed setpoint control .................................................................................... 13

6 Cycle diagrams .......................................................................................................................   156.1 Jog mode ...................................................................................................................... 156.2 Referencing mode......................................................................................................... 166.3 Positioning mode .......................................................................................................... 176.4 Speed mode without encoder ....................................................................................... 186.5 Prioritized fixed setpoint control .................................................................................... 19

2673

3617

/EN

– 0

6/20

20

Page 4: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

Table of contents

Manual – ALX0517 Application Module4

7 Startup .....................................................................................................................................   207.1 Preparing startup .......................................................................................................... 207.2 Starting the application module..................................................................................... 20

7.2.1 Via the context menu ...................................................................................   207.2.2 Via the tool start page ..................................................................................   217.2.3 Initial screen .................................................................................................   21

7.3 Setting the application module...................................................................................... 227.3.1 General settings ...........................................................................................   227.3.2 Scaling .........................................................................................................   257.3.3 Monitoring ....................................................................................................   267.3.4 Reference travel ...........................................................................................   29

8 Operation and diagnostics ....................................................................................................   318.1 Monitor mode ................................................................................................................ 318.2 Control mode ................................................................................................................ 328.3 Diagnostics with the S12 safety option ......................................................................... 33

8.3.1 Description ...................................................................................................   338.3.2 S12 diagnostics view....................................................................................   338.3.3 Structure of process data .............................................................................   33

8.4 Extended process data word ........................................................................................ 34

9 Data management...................................................................................................................   369.1 Activating data management ........................................................................................ 379.2 Structure of process data.............................................................................................. 39

10 Terminal assignment..............................................................................................................   4010.1 EI7C incremental encoder ............................................................................................ 4010.2 F5868 absolute encoder ............................................................................................... 41

11 Process data ...........................................................................................................................   4211.1 Overview ....................................................................................................................... 4211.2 Process data assignment.............................................................................................. 42

11.2.1 Process input data .......................................................................................   4211.2.2 Process output data .....................................................................................   44

Index ........................................................................................................................................   4626

7336

17/E

N –

06/

2020

Page 5: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

1General informationAbout this documentation

Manual – ALX0517 Application Module 5

1 General information1.1 About this documentation

This documentation is an integral part of the product. The documentation is intendedfor all employees who perform work on the product.Make sure this documentation is accessible and legible. Ensure that persons respon-sible for the systems and their operation as well as persons who work with the productindependently have read through the documentation carefully and understood it. If youare unclear about any of the information in this documentation, or if you require furtherinformation, contact SEW‑EURODRIVE.

1.2 Content of the documentationThe descriptions in this documentation apply to the software and firmware versionsapplicable at the time of publication. These descriptions might differ if you install latersoftware or firmware versions. In this case, contact SEW‑EURODRIVE.

1.3 Applicable documentation

Observe the following other applicable documentation:• "MOVIFIT® Function Level Technology with PROFINET IO Interface" manual• "MOVIFIT® Function Level Technology with EtherNet/IP™ or Modbus/TCP Inter-

face" manual• "MOVIFIT® MC/FC – Functional Safety with S12 Safety Option" manualAlways use the latest edition of the documentation and the software.The SEW‑EURODRIVE website (www.sew‑eurodrive.com) provides a wide selectionof documents for download in various languages. If required, you can also order prin-ted and bound copies of the documentation from SEW‑EURODRIVE.

1.4 Structure of the warning notes1.4.1 Meaning of signal words

The following table shows the grading and meaning of the signal words for safetynotes.

Signal word Meaning Consequences if disregarded

 DANGER Imminent hazard Severe or fatal injuries

 WARNING Possible dangerous situation Severe or fatal injuries

 CAUTION Possible dangerous situation Minor injuries

NOTICE Possible damage to property Damage to the product or its envi-ronment

INFORMATION Useful information or tip: Simplifieshandling of the product.

2673

3617

/EN

– 0

6/20

20

Page 6: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

1 General informationDecimal separator in numerical values

Manual – ALX0517 Application Module6

1.4.2 Structure of section-related safety notesSection-related safety notes do not apply to a specific action but to several actionspertaining to one subject. The hazard symbols used either indicate a general hazardor a specific hazard.This is the formal structure of a safety note for a specific section:

SIGNAL WORDType and source of hazard.Possible consequence(s) if disregarded.• Measure(s) to prevent the hazard.

Meaning of the hazard symbolsThe hazard symbols in the safety notes have the following meaning:

Hazard symbol MeaningGeneral hazard

1.4.3 Structure of embedded safety notesEmbedded safety notes are directly integrated into the instructions just before the de-scription of the dangerous action.This is the formal structure of an embedded safety note:

 SIGNAL WORD! Type and source of hazard. Possible consequence(s) if disregar-ded. Measure(s) to prevent the hazard.

1.5 Decimal separator in numerical values

In this document, a period is used to indicate the decimal separator.Example: 30.5 kg

1.6 Rights to claim under limited warrantyRead the information in this documentation. This is essential for fault-free operationand fulfillment of any rights to claim under limited warranty. Read the documentationbefore you start working with the product.

1.7 Terms and conditions of use

SEW‑EURODRIVE grants the temporarily unrestricted right to use a copy of the soft-ware including the corresponding documentation and media (together called "mater-ial") according to the detailed terms of use and other contractual agreements.

2673

3617

/EN

– 0

6/20

20

Page 7: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

1General informationProduct names and trademarks

Manual – ALX0517 Application Module 7

Updates or extensions to the applicable material that are provided as part of an agree-ment of transfer of possession or other contract (such as maintenance contract) arealso part of the material provided.The complete material belongs to SEW‑EURODRIVE and is protected by copyright. Ifno legal exceptions apply, it is expressly forbidden to:• Reproduce the material temporarily or permanently, in whole or in part, except for

the purpose of designated and contractual uses, or for the creation of a legally per-mitted backup to ensure future use.

• Translate or modify the software, or to reproduce the results achieved.You are obliged to prevent unauthorized access of third parties to the provided mater-ial. SEW‑EURODRIVE remains the proprietor of all rights, even if you modify the ma-terial or combine it with your own or third party programs.If detailed terms of use are displayed during the software installation and must be ac-cepted before the software can be used, these also apply in addition to the terms ofuse described here.

1.8 Product names and trademarks

The brands and product names in this documentation are trademarks or registeredtrademarks of their respective titleholders.

1.9 Copyright notice

© 2020 SEW‑EURODRIVE. All rights reserved. Unauthorized reproduction, modifica-tion, distribution or any other use of the whole or any part of this documentation isstrictly prohibited.

1.10 Short designationThe following short designations are used in this documentation.

Type designation Short designationALX0517 application module Application module

2673

3617

/EN

– 0

6/20

20

Page 8: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

2 Safety notesPreliminary information

Manual – ALX0517 Application Module8

2 Safety notes2.1 Preliminary information

The following general safety notes serve the purpose of preventing injury to personsand damage to property. They primarily apply to the use of products described in thisdocumentation. If you use additional components, also observe the relevant warningand safety notes.

2.2 Target group

Software specialist Any work with the software may only be performed by a specialist with suitable train-ing. A specialist in this context is someone who has the following qualifications:• Appropriate training• Knowledge of this documentation and other applicable documentation• SEW‑EURODRIVE recommends additional training for products that are operated

using this software.The above-mentioned persons must have the authorization expressly issued by thecompany to operate, program, configure, label, and ground devices, systems, and cir-cuits in accordance with the standards of safety technology.

2.3 Network security and access protectionA bus system makes it possible to adapt electronic drive technology components tothe particulars of the machinery within wide limits. There is a risk that a change of pa-rameters that cannot be detected externally may result in unexpected but not uncon-trolled system behavior and may have a negative impact on operational safety, systemavailability, or data security.Ensure that unauthorized access is prevented, especially with respect to Ethernet-based networked systems and engineering interfaces.Use IT‑specific safety standards to increase access protection to the ports. For a portoverview, refer to the respective technical data of the device in use.

2.4 Designated use

The application module is a single-axis application and used to approach variable pos-itions with different speeds and ramps or to move with different speeds and rampswhen operated without encoder.The application module is implemented with a decentralized MOVIFIT® FC controllerwith "Technology" function level using the following fieldbus interfaces:• PROFINET IO• EtherNet/IPTM

• Modbus TCP

2673

3617

/EN

– 0

6/20

20

Page 9: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

3Project planning informationRequirements

Manual – ALX0517 Application Module 9

3 Project planning information3.1 Requirements

Correct configuration and proper installation of the units are required for successfullystarting up and operating the application modules with the Application Configurator.You find detailed configuration information in the documentation of the respective units(see chapter "Other applicable documentation").

3.2 PC and softwareIn order to use the application module, you require a PC with a Windows® operatingsystem and MOVITOOLS® MotionStudio (version 6.2.0.1 or higher with the appropri-ate plug-in).

3.3 ControllerThe application module is implemented with a decentralized MOVIFIT® FC controllerwith "Technology" function level using the following fieldbus interfaces:• PROFINET IO• EtherNet/IPTM

• Modbus TCP

3.4 EncoderThe application module allows for operation without encoder, with the EI7C incre-mental encoder or the Kübler F5868 CAN absolute encoder. Both encoders are scaledto 96 increments.

2673

3617

/EN

– 0

6/20

20

Page 10: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

4 System descriptionArea of application

Manual – ALX0517 Application Module10

4 System description

4.1 Area of applicationThe application module is used for variable positions in conjunction with differentspeeds and ramps.Positioning is carried out via built-in motor encoder or optionally via external encoder.In addition, prioritized fixed setpoint control is possible when operated without en-coder.Only the linear, absolute positioning is supported. You can work with user units.The following operating modes are available:• Jog mode• Referencing mode• Positioning mode/speed mode

4.2 Overview of the systemThe application module allows the configuration of the following encoder versions:

With EI7C incrementalencoder

With F5868 absolute encoderNo encoder, with prioritizedfixed setpoint control via

binary signals

CANDigital inputCW

Digital inputCCW

18014422032483851

The following table provides an overview of the operating modes that can be imple-mented with the respective encoders and if the "Prioritized fixed setpoint control" func-tion is available.

Encoder version Operating mode "Prioritized fixed setpointcontrol" function

No encoder Speed mode Available

EI7C incremental encoder Positioning mode Not available

2673

3617

/EN

– 0

6/20

20

Page 11: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

4System descriptionProfiles

Manual – ALX0517 Application Module 11

Encoder version Operating mode "Prioritized fixed setpointcontrol" function

F5868 absolute encoder Positioning mode Not available

4.3 ProfilesThe application module has the following profile:

Profile Scope of functions8 PD 2 process data words for the state of the controller

6 process data words for the drive

The process data assignment for the profile is listed in chapter "Processdata" (→ 2 42).

Optional:• Extended process data word 9 for the data management function

For further information, refer to chapter "Data management" (→ 2 36).• 3 additional process data words for the S12 safety option

For further information, refer to chapter "Diagnostics with the S12 safety op-tion" (→ 2 33).

2673

3617

/EN

– 0

6/20

20

Page 12: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

5 Operating modesJog mode

Manual – ALX0517 Application Module12

5 Operating modes5.1 Jog mode

In jog mode, you can move the drive independently of the other operating modes ofthe system.In jog mode, you can set the control bits "Jog+" or "Jog-" to move the drive clockwiseor counterclockwise. It is not necessary to set the start bit.Speed and ramps are specified dynamically via the corresponding process datawords.

5.2 Referencing modeThe referencing determines the reference point (machine zero) for positioning opera-tions.Referencing is triggered by the hardware limit switch. Operating mode "Mode 2" is se-lected for the reference travel (see chapter "Process data" and "Terminal assign-ment").Once the start bit has been set, the drive moves to the hardware limit switch specifiedduring startup when reference travel type 3 and 4 are selected. Then the drive movesclear independently. When reference travel type 5 is selected, the drive is referencedat the spot where it is located, without moving.

5.3 Speed mode5.3.1 Speed mode without encoder

Configuring speed mode without encoder.To do so, select "No encoder" in the encoder field during configuration.Speed and ramps are specified dynamically via the corresponding process datawords. As positioning is not possible, a position specification is not required and posi-tion feedback is not issued.

5.4 Positioning mode5.4.1 Positioning mode with EI7C incremental encoder

Using an EI7C incremental encoder in positioning mode.To do so, select "EI7C incremental encoder" in the encoder field during configuration.Prior to positioning, you have to perform a reference travel. All positioning travels referto the machine zero specified during referencing.The dynamics parameters as well as the target position are specified dynamically viathe corresponding process data words. The drive moves once the start bit has beenset. If the actual position does not deviate from the target position further than the po-sition window, the "Target position reached" bit is set.

2673

3617

/EN

– 0

6/20

20

Page 13: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

5Operating modesPrioritized fixed setpoint control

Manual – ALX0517 Application Module 13

5.4.2 Positioning mode with F5868 absolute encoder

CAUTIONIncorrect positioning due to exceeded work envelope.Damage to property and disruption of the process sequence• Configure the system in such a way that the work envelope of ±32768 motor re-

volutions is not exceeded in positioning mode with F5868 absolute encoder.

Using an F5868 absolute encoder in positioning mode.To do so, select "F5868 absolute encoder" in the encoder field during configuration.Prior to positioning, you have to perform a reference travel once. The reference posi-tion is maintained even after de-energizing. All positioning travels refer to the machinezero specified during referencing.The dynamics parameters as well as the target position are specified dynamically viathe corresponding process data words. The drive moves once the start bit has beenset. If the actual position does not deviate from the target position further than the po-sition window, the "Target position reached" bit is set.The work envelope in positioning mode with F5868 absolute encoder is ±32768 motorrevolutions based on the reference point.

5.5 Prioritized fixed setpoint control

INFORMATIONPrioritized fixed setpoint control is only possible if no emergency switch-off function(STO) is active.

INFORMATIONIgnored error states during prioritized fixed setpoint control.• If an error is present when changing from normal operation to prioritized fixed set-

point control, the error is automatically reset.• If an error occurs again during the fixed setpoint enable, the MOVIFIT® inverter re-

sponds according to the error response stored internally.

Configuring a prioritized fixed setpoint control. The configuration for the prioritizedfixed setpoint control is only possible for drives without encoder.To do so, select "No encoder" in the encoder field during configuration and activatethe "Prioritized fixed setpoint" function.If a signal is detected at the parameterized input "Digital input CW" or at the input "Di-gital input CCW", all other control signals such as process data, controller inhibit andenable are deactivated and the parameterized fixed setpoint is used. Signal detectionat the "Digital input CW" input results in moving with positive speed. Signal detectionat the "Digital input CCW" input results in moving with negative speed.If a signal is detected at both inputs at the same time, no travel movement takesplace. If no signal is detected, the setpoints specified by the higher-level controller areused.If an inverter fault occurs, the reset bit is not cyclically toggled, but remains set per-manently. Travel movement is then not possible without a fault reset.

2673

3617

/EN

– 0

6/20

20

Page 14: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

5 Operating modesPrioritized fixed setpoint control

Manual – ALX0517 Application Module14

When the prioritized fixed setpoint control is activated via the "Digital input CW" inputor the "Digital input CCW" input, the process data bit 4 "PO data enabled" is reset inPO3. For further information, refer to section "Process data" in chapter "Process out-put data" (→ 2 44).

2673

3617

/EN

– 0

6/20

20

Page 15: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

6Cycle diagramsJog mode

Manual – ALX0517 Application Module 15

6 Cycle diagrams6.1 Jog mode

The following figure shows the actual speed of the drive against the status of the inputand output signals in jog mode.

123

[1]

n

[2]

[3]

13213654027

 n Actual speed[1] "Mode" input signal[2] Input signal "positive" (jog+)[3] Input signal "negative" (jog–)

2673

3617

/EN

– 0

6/20

20

Page 16: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

6 Cycle diagramsReferencing mode

Manual – ALX0517 Application Module16

6.2 Referencing modeThe following figure shows the actual speed of the drive against the status of the inputand output signals in referencing mode.

123

[1]

n

[2]

[3]

[4]

13213983371

 n Actual speed[1] "Mode" input signal[2] "Start" input signal[3] "HWLS" input signal1)

[4] "Drive referenced" output signal1) HWLS = hardware limit switch

2673

3617

/EN

– 0

6/20

20

Page 17: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

6Cycle diagramsPositioning mode

Manual – ALX0517 Application Module 17

6.3 Positioning modeThe following figure shows the actual speed of the drive against the status of the inputand output signals in positioning mode.

123

[1]

n

[2]

[3]

[4]

13214527371

 n Actual speed[1] "Mode" input signal[2] "Start" input signal[3] "Target position reached" output signal[4] "PI4/PI5 Setpoint position" input signal

2673

3617

/EN

– 0

6/20

20

Page 18: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

6 Cycle diagramsSpeed mode without encoder

Manual – ALX0517 Application Module18

6.4 Speed mode without encoderThe following figure shows the actual speed against the status of the input signals orthe specified setpoint speed.

9007222089316619

n Actual speed[1] "Mode" input signal[2] "Start" input signal[3] PI6 Setpoint speed

2673

3617

/EN

– 0

6/20

20

Page 19: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

6Cycle diagramsPrioritized fixed setpoint control

Manual – ALX0517 Application Module 19

6.5 Prioritized fixed setpoint controlThe following figure shows the actual speed against the switching status of the digitalinputs "Digital input CW" or "Digital input CCW" and the configured fixed setpoint.

22881131787

n Actual speed[1] Digital input CW (configured as NO contact)[2] Digital input CCW (configured as NC contact)

2673

3617

/EN

– 0

6/20

20

Page 20: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7 StartupPreparing startup

Manual – ALX0517 Application Module20

7 Startup7.1 Preparing startup

Perform the following steps before startup:1. Check the installation of the MOVIFIT® and the encoder connection based on the

installation notes in the corresponding documentation.2. Connect MOVIFIT® to your PC or laptop.3. Install the MOVITOOLS® MotionStudio engineering software on your PC or laptop.4. Start the MOVITOOLS® MotionStudio engineering software.

For more information on starting the MOVITOOLS® MotionStudio engineering soft-ware, refer to the "MOVITOOLS® MotionStudio" manual.

7.2 Starting the application module7.2.1 Via the context menu

Proceed as follows:ü The MOVITOOLS® MotionStudio engineering software is started.1. Select the relevant device node.2. Right-click to open the context menu.3. Select the [Airport] / [ALX0517] menu command.

18014421344871179

ð The start window of the application module is displayed.26

7336

17/E

N –

06/

2020

Page 21: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7StartupStarting the application module

Manual – ALX0517 Application Module 21

7.2.2 Via the tool start pageProceed as follows:ü The MOVITOOLS® MotionStudio engineering software is started.1. Select the relevant device node.2. On the tool start page, select [ALX0517] in the [Airport] section.

9007222090134411

ð The start window of the application module is displayed.

7.2.3 Initial screen

[1]

[2]

[3][4]

9007222100022923

No. Description[1] Use this button to monitor the application.

[2] Use this button to download the configuration.

[3] This area provides information on part number, version and release in offlineand online mode.

[4] Use this button to go to the next configuration step.

2673

3617

/EN

– 0

6/20

20

Page 22: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7 StartupSetting the application module

Manual – ALX0517 Application Module22

7.3 Setting the application module7.3.1 General settings

[1]

[2]

[3]

[4][5]

[6]

[7]

9007222101885067

No. Description[1] The fieldbus address is displayed in this display field.

[2] Use this drop-down list to activate the configuration of an extended processdata word:• Extended PD active• Extended PD inactiveWhen activated, the process data interface is extended with the extended pro-cess data word at the 9th position.

[3] Select the timeout response in this drop-down list:• No response• Controller inhibit• Rapid stop (default setting)• Stop

[4] Select the repositioning in this drop-down list:• Activated (default setting)

The positive edge at the "in position" output signal causes the brake to ap-ply. If the output signal "in position" is reset (e.g. by exceeding the positionwindow), repositioning is triggered.

• DeactivatedThe positive edge at the "in position" output signal causes the brake to ap-ply. However, this setting will not trigger a repositioning even if the positionwindow is exceeded. Only a new starting edge triggers a new positioning.

2673

3617

/EN

– 0

6/20

20

Page 23: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7StartupSetting the application module

Manual – ALX0517 Application Module 23

No. Description[5] Select the used encoder in this drop-down list:

• No encoder• F5868 absolute encoder• EI7C incremental encoderDepending on the selected setting, more fields are displayed in this window.These additional settings are described in chapters "F5868 absolute en-coder" (→ 2 23) and "No encoder" (→ 2 24).

[6] Use this drop-down list to activate the diagnostics with S12 safety option:• Activated• DeactivatedFor further information, refer to chapter "Diagnostics with S12 safety op-tion" (→ 2 33).

[7] Use this button to go to the next step.

1. Select the required parameter.2. To go to the next step, use the button [7].

F5868 absolute encoder

[1][2]

9007222101889931

No. Description[1] In this drop-down list, you activate the direction of rotation reversal at the mo-

tor:• Deactivated• Activated

[2] In this drop-down list, you activate the direction of rotation reversal at the en-coder:• Deactivated• Activated

2673

3617

/EN

– 0

6/20

20

Page 24: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7 StartupSetting the application module

Manual – ALX0517 Application Module24

No encoder

[1][2][3][4][5][6]

9007222102394891

No. Description[1] In this drop-down list, you activate the "Prioritized fixed setpoint" function:

• Activated• Deactivated

[2] Here you set the speed when moving via the "Prioritized fixed setpoint" func-tion.

[3] In this drop-down list, you specify the input for connection with the "Digital in-put CW":• DI00 .. DI15• DI10 (default setting)

[4] In this drop-down list, you select the "Sensor CW" type:• NO contact• NC contact

[5] In this drop-down list, you specify the input for connection with the "Digital in-put CCW":• DI00 .. DI15• DI11 (default setting)

[6] In this drop-down list, you select the "Sensor CCW" type:• NO contact• NC contact

2673

3617

/EN

– 0

6/20

20

Page 25: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7StartupSetting the application module

Manual – ALX0517 Application Module 25

7.3.2 Scaling

[1][2][3][4][5][6]

[10]

[7]

[8]

[9]

23216872715

No. Description[1] Select the calculation scheme in this drop-down list:

• Motor shaft (default setting)• Drive wheel• Spindle

[2] This edit box displays the value for the encoder resolution in [Inc/rpm].

[3] The gear ratio of the gear unit is displayed in this display field. With calculationscheme "drive wheel" or "spindle", enter the gear ratio of the gear unit here.

[4] Enter the gear ratio of the additional transmission in this edit box.

[5] Either the diameter or the spindle pitch is displayed in this display field. Withcalculation scheme "drive wheel" or "spindle", enter either the diameter or thespindle pitch here and select the relevant unit.

[6] With calculation scheme "motor shaft", you can read the unit of the velocityhere.With calculation scheme "drive wheel" or "spindle", select the unit of the velo-city from the drop-down list:• [rpm]• [mm/s]• [m/min]

[7] After completing all entries, calculate the total scaling factors (numerator / de-nominator) for "distance" and "velocity" with this button.

[8] If you do not use the button [7], enter the values (numerator / denominator) forthe scaling factor "distance" in [Inc.] in this group. Value range: 1 – 65535 inc.

[9] If you do not use the button [7], enter the values (numerator / denominator) forthe scaling factor "velocity" in [rpm] in this group. Value range: 1 – 65535 rpm.

[10] Use this button to go to the next step.

2673

3617

/EN

– 0

6/20

20

Page 26: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7 StartupSetting the application module

Manual – ALX0517 Application Module26

INFORMATIONTo operate the application module with user-defined units, you must enter the corre-sponding scaling parameters. This includes the mechanical parameters of the drivetrain (gear unit ratio and shaft circumference) and the user-defined units that areused to calculated the scaling.

1. Select the required parameter.2. To go to the next step, use the button [10].

7.3.3 Monitoring

[1][2]

[3][4][5]

[6]

[7]

[8]

23227888651

No. Description[1] Enter the monitoring time for the encoder monitoring in [ms] in this edit box.

INFORMATION: The monitoring time is the interval in which the encoder sig-nal regarding changes and direction is checked. With monitoring time = 0, theencoder monitoring is disabled.

[2] To create the message "in position", enter the value for the position window in[inc.] in this edit box.INFORMATION: Recommended setting = 1/2 motor revolution.

[3] Activate or deactivate the hardware limit switch in this drop-down list (see sec-tion "hardware limit switch").

[4] Enter the value for the software limit switch CCW in [inc.] in this edit box.

[5] Enter the value for the software limit switch CW in [inc.] in this edit box.

[6] Enter the maximum motor speed for the positioning mode/speed mode in [rpm]that is determined via the fieldbus into this edit box.

[7] Enter the maximum motor speed for the jog mode in [rpm] that is determinedvia the fieldbus into this edit box.

[8] Use this button to go to the next step.

1. Set the required parameters (see sections "Position windows" and "Limitswitches").

2. To go to the next step, use the button [8].

2673

3617

/EN

– 0

6/20

20

Page 27: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7StartupSetting the application module

Manual – ALX0517 Application Module 27

Position windowThe following figure illustrates the meaning of the position window.

[2]

[3]

[1]

[4]

36028802606743691

[1] In position[2] Target position[3] Position window[4] Actual position

If the actual position is in the position window [3] when the monitoring function is ac-tive, this "in position" signal is issued. The signal is only revoked when the driveleaves the position window.

Hardware limit switches• "Activated":

This setting activates monitoring of the positive and negative limits using hardwarelimit switches.For the assignment of the input terminals with the hardware limit switches, refer tochapters "Process data" and "Terminal assignment".

• "Deactivated":This setting deactivates the monitoring.

When using the hardware limit switches, they have to be designed as NC contacts forwire-break protection reasons (low = limit switch contacted). In the travel range, thehardware limit switches are located after the software limit switches if such are used.Response when a hardware limit switch is reached:The axis is decelerated with the currently set ramp value. The inverter issues the error"Hardware limit switch reached" (F29). After an "error reset", the drive moves clear ofthe hardware limit switch with the retraction speed (reference velocity 2) and the erroris deleted. The retraction speed is accelerated and decelerated with the values for"enable/rapid stop".

Software limit switchesA value (≠ 0) in the respective field activates monitoring of the positive and negativelimits using software limit switches. The permitted travel range is defined by the posit-ive and negative limits.

2673

3617

/EN

– 0

6/20

20

Page 28: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7 StartupSetting the application module

Manual – ALX0517 Application Module28

In the travel range, the software limit switches are located before the hardware limitswitches if such are used.Response when a software limit switch is reached:When the drive moves past a software limit switch in "jog" or "positioning/speed"mode, the axis decelerates with the currently set ramp value. The application errormessage "CW software limit switch reached" (F78) or "CCW software limit switchreached" (F78) is issued.A "fault reset" and moving the axis in the direction of the permitted travel range movesthe drive clear of the software limit switch and deletes the fault. The velocity, accelera-tion, and deceleration values of the selected operating mode apply.

2673

3617

/EN

– 0

6/20

20

Page 29: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7StartupSetting the application module

Manual – ALX0517 Application Module 29

7.3.4 Reference travel

[1]

[2]

[3]

[4][5]

[6]

[7]

23217056267

No. Description[1] Select the reference travel type in this drop-down list:

• Type 3: Limit switch CW• Type 4: Limit switch CCW• Type 5: No reference travel

[2] Enter the search velocity in [rpm] in this edit box.INFORMATION: If a reference cam is used for reference travel, the drivemoves towards the reference cam with the search velocity and away from thereference cam with the retraction speed.

[3] Enter the retraction speed in [rpm] in this edit box.

[4] Enter the acceleration ramp in [rpm] in this edit box.

[5] Enter the deceleration ramp in [rpm] in this edit box.

[6] Enter the reference offset in [inc] in this edit box.Based on the reference point that was determined during reference travel, youcan now move the machine zero using the reference offset function.The new machine zero is calculated according to the following formula:Machine zero = reference position – reference offsetThe reference offset is given in user units.

[7] Use this button to go to the next step.

Reference travel typeThe reference travel type defines how the reference travel is performed. This settingalso defines the search direction in the individual referencing phases.The following reference travel types are available:• Type 3: Limit switch CW

– First search direction is CW.– Reference point = falling edge to the left of the CW limit switch.– Machine zero = reference position + reference offset.

• Type 4: Limit switch CCW

2673

3617

/EN

– 0

6/20

20

Page 30: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

7 StartupSetting the application module

Manual – ALX0517 Application Module30

– First search direction is CCW.– Reference point = falling edge to the right of the CCW limit switch.– Machine zero = reference position + reference offset.

• Type 5: No reference travel– Reference point = position where the drive is located.– There is no travel movement.

INFORMATION• All reference travel types require an enabled drive ready for operation.

2673

3617

/EN

– 0

6/20

20

Page 31: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

8Operation and diagnosticsMonitor mode

Manual – ALX0517 Application Module 31

8 Operation and diagnostics8.1 Monitor mode

In monitor mode, you can monitor the functions of the application module.

[1]

[2]

[3]

[4]

[5]

[6]

[7]

23616588555

No. Meaning[1] This field shows the process input and output data in hexadecimal format.

[2] Use this button to switch to control mode.

[3] In this area, the process output data is displayed in plain text (see chapter"Process data").

[4] In this area, the extended control word is displayed in plain text.INFORMATION: If the configuration of the extended process data word is de-activated in the general settings, this group is not displayed (see chapter "Pro-cess data configuration").

[5] In this area, the process input data of the S12 safety option is displayed.INFORMATION: If diagnostics with S12 safety option is deactivated in thegeneral settings, this group is not displayed (see chapter "Diagnostics with theS12 safety option").

[6] In this area, the extended status word is displayed in plain text.INFORMATION: If the configuration of the extended process data word is de-activated in the general settings, this group is not displayed (see chapter "Pro-cess data configuration").

[7] In this area, the process input data is displayed in plain text (see chapter "Pro-cess data").

2673

3617

/EN

– 0

6/20

20

Page 32: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

8 Operation and diagnosticsControl mode

Manual – ALX0517 Application Module32

8.2 Control modeIn control mode, you can control the functions of the application module and changethe state of the bit in the control word and the digital outputs.

[1]

[2][3]

[4]

[6]

[7][5]

[8]

[9][10]

23622360331

No. Meaning[1] This field shows the process input and output data in hexadecimal format.

[2] Use this button to transfer the changed setpoints to the MOVIFIT®.

[3] Use this button to switch to monitor mode.

[4] In this area, the process output data is displayed in plain text (see chapter"Process data").

[5] In this area, the extended control word is displayed in plain text.INFORMATION: If the configuration of the extended process data word is de-activated in the general settings, this group is not displayed (see chapter "Pro-cess data configuration").

[6] In this area, the process input data of the S12 safety option is displayed.INFORMATION: If diagnostics with S12 safety option is deactivated in thegeneral settings, this group is not displayed (see chapter "Diagnostics with theS12 safety option").

[7] In this area, the extended status word is displayed in plain text.INFORMATION: If the configuration of the extended process data word is de-activated in the general settings, this group is not displayed (see chapter "Pro-cess data configuration").

[8] In this area, the process input data is displayed in plain text (see chapter "Pro-cess data").

[9] Use this button to set the controller inhibit.

[10] Use this button to stop the axis immediately via the rapid stop ramp.

2673

3617

/EN

– 0

6/20

20

Page 33: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

8Operation and diagnosticsDiagnostics with the S12 safety option

Manual – ALX0517 Application Module 33

8.3 Diagnostics with the S12 safety option8.3.1 Description

S12 diagnostics provides status and diagnostics information of the S12 safety optionvia the process data on the "non-safe fieldbus part".If S12 diagnostics is activated, the process data (3PD) are automatically attached tothe existing configuration.

8.3.2 S12 diagnostics viewOpen S12 diagnosticsProceed as follows:1. Activate the S12 diagnostics in the parameter settings.2. Switch to monitor mode.

ð On the bottom of the monitor mode window, the following area is displayed.

[1]

[2]

[3]

23617823115

No.

Description

[1] This switch group shows the process data word PI1 (safety functions).

[2] This switch group shows the process data word PI2 (safety state).

[3] This display field shows the process data word PI3 (error number).

For detailed information on the process data, refer to the chapter "Structure of processdata".

8.3.3 Structure of process dataThe following tables show the structure of the process data words.

Process data DesignationPI1 Safety functions

PI2 Safety status

PI3 Error number: 0x0000• Error number as entire data word 0: no error• For detailed information on the error number, refer to the

"MOVIFIT® MC/FC Functional Safety with S12 Safety Option"manual, chapter "Error table of S12 safety option".

2673

3617

/EN

– 0

6/20

20

Page 34: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

8 Operation and diagnosticsExtended process data word

Manual – ALX0517 Application Module34

Word Bit FunctionPI1 0 STO active

1 STO error

2 SS1(a) active

3 SS1(c) active

4 SLS0 active

5 SLS1 active

6 SLS2 active

7 SLS3 active

8 FDO-STO

9 FDO-0

10 FDO-1

11 Reserved

12 Reserved

13 Reserved

14 Reserved

15 Reserved

Word Bit FunctionPI2 0 S12 status:

0: Init1: Parameter setting2: Validated3: Start4: RUN5: STOP

1

2

3

4

5

6

7

8 FDI-0

9 FDI-1

10 FDI-2

11 FDI-3

12 FDI-4

13 FDI-5

14 FDI-6

15 FDI-7

8.4 Extended process data wordIn the general settings, you can configure an extended process data word.

2673

3617

/EN

– 0

6/20

20

Page 35: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

8Operation and diagnosticsExtended process data word

Manual – ALX0517 Application Module 35

The extended process data word is set to the 9th position as 9th process data word.

Configuring extended process data wordProceed as follows:1. Activate the configuration of an extended process data word in the general settings

(see chapter "General settings").2. Switch to monitor mode.

ð The following window is displayed.

[5]

[1][2]

[3]

[4]

[6]

23622368139

No. Description[1] Bit 0 if the extended status word (reserved).

[2] Use this button to show or hide the meanings of the single bits of the extendedstatus word.

[3] This group shows the extended status word.

[4] Use this button to show or hide the meanings of the single bits of the extendedcontrol word.

[5] Bit 0 of the extended control word (download data set).

[6] This group shows the extended control word.

2673

3617

/EN

– 0

6/20

20

Page 36: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

9 Data management

Manual – ALX0517 Application Module36

9 Data managementThe data management function is available for MOVIFIT® FC units with the followingfieldbus interfaces:• PROFINET IO• EtherNet/IPTM

• Modbus TCPTo enable data management, the application module must already be installed on theEBOX (active electronics unit) (delivery state).This has the following reasons:• Data management can only store the application and device parameters on the

ABOX (passive connection unit). The boot project cannot be stored on the ABOXbecause there is not sufficient memory space available.

INFORMATIONFor proper functioning of the data management function, the MOVIFIT® devices mustbe operated in expert mode (see "MOVIFIT® FC" operating instructions, "MOVIFIT®

Function Level with PROFINET  IO Interface" manual or "MOVIFIT® Function LevelTechnology with EtherNet/IP™ or Modbus TCP interface" manual). To activate datamanagement and the control via fieldbus, an upload from the data management sur-face in MOVITOOLS® MotionStudio must be performed once.

2673

3617

/EN

– 0

6/20

20

Page 37: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

9Data managementActivating data management

Manual – ALX0517 Application Module 37

9.1 Activating data managementProceed as follows:ü The application module is already installed on the EBOX.1. Start the MOVITOOLS® MotionStudio engineering software.2. Open the data management surface.3. To switch to the upload function, click the button [1].

[1]

23615590155

ð The following window is displayed.

2673

3617

/EN

– 0

6/20

20

Page 38: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

9 Data managementActivating data management

Manual – ALX0517 Application Module38

[1]

[2]

[3]

23616582667

No. Meaning[1] If this check box is checked, the control of the data management via process

data is enabled after successful upload.

[2] If the check box [Auto reload] is checked, the application and device parame-ters are automatically reloaded after a device replacement.

[3] Click this button to start the upload.

4. Activate the required functions.5. Click the button [3] and perform an upload once.For detailed information on the process data, refer to the chapter "Process data andterminal assignment".

2673

3617

/EN

– 0

6/20

20

Page 39: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

9Data managementStructure of process data

Manual – ALX0517 Application Module 39

9.2 Structure of process dataThe following tables show the structure of the process data words.

Process data DesignationPO9 Extended control word

PI9 Extended status word

Word Bit FunctionPO9 0 Download dataset

1 Upload dataset

2 Upload data set with auto reload

3 Reserved

4 Reserved

5 Reserved

6 Reboot system

7 Digital output DO00

8 Digital output DO01

9 Digital output DO02

10 Digital output DO03

11 – 15 Reserved

Word Bit FunctionPI9 0 Reserved

1 Toggle bit

2 Data management done

3 Data management busy

4 Data set available

5 Auto-reload configured

6

7

8

9

10

11 – 15

2673

3617

/EN

– 0

6/20

20

Page 40: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

10 Terminal assignmentEI7C incremental encoder

Manual – ALX0517 Application Module40

10 Terminal assignmentThe following table shows the assignment of the digital inputs.

INFORMATIONAll inputs marked as "Reserved" can be used for prioritized fixed setpoint control.

Input FunctionDI00 Right hardware limit switch

DI01 Left hardware limit switch

DI02 Reserved

DI03 Reserved

DI04 HTL encoder track A

DI05 HTL encoder track B

DI06-DI09 Reserved

DI10 Prioritized fixed setpoint control digital input CW(default setting)

DI11 Prioritized fixed setpoint control digital input CCW(default setting)

DI12-DI15 Reserved

10.1 EI7C incremental encoderInstallation takes place at terminal X25 according to the description in theMOVIFIT® FC hardware documentation.The following table shows the terminal assignment:

No. Name FunctionX25 3 DI04 Digital input DI04

HTL encoder track A

13 DI05 Digital input DI05HTL encoder track B

23 VO24-II +24V sensor supply group II (DI04 – DI07) from +24V_C

33 0V24_C 0V24 reference potential for sensors

2673

3617

/EN

– 0

6/20

20

Page 41: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

10Terminal assignmentF5868 absolute encoder

Manual – ALX0517 Application Module 41

10.2 F5868 absolute encoderInstallation takes place at terminal X35 according to the description in theMOVIFIT® FC hardware documentation.The following table shows the terminal assignment:

No. Name FunctionX35 1 CAN_GND 0 V reference potential for SBus (CAN)

2 CAN_H SBus CAN_H - incoming

3 CAN_L SBus CAN_L - incoming

4 +24V_C_PS +24 V supplyContinuous voltage for peripheral devices

5 0V24_C +0V24 reference potentialContinuous voltage for peripheral devices (jumpered withX20/3)

2673

3617

/EN

– 0

6/20

20

Page 42: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

11 Process dataOverview

Manual – ALX0517 Application Module42

11 Process data11.1 Overview

The following table shows the process data assignment.

Profile Process data assignmentProcess input data Process output data

8 PD PI1 = ReservedPI2 = 4DO

PO1 = StatusPO2 = 16DI

PI3 = Control wordPI4 = Setpoint position (high word)PI5 = Setpoint position (low word)PI6 = Setpoint speedPI7 = Acceleration rampPI8 = Deceleration ramp

PO3 = Status wordPO4 = Actual position (high word)PO5 = Actual position (low word)PO6 = Actual speedPO7 = Output currentPO8 = Reserved

INFORMATIONFor the process data assignment of the extended process data word PD9, refer tosection "Data management" in chapter "Process data structure" (→ 2 39).For the process data assignment of the S12 safety option, refer to section "Diagnos-tics with S12 safety option" in chapter "Process data structure" (→ 2 33).

11.2 Process data assignment11.2.1 Process input data

The following table shows the process input data from the PLC to the MOVIFIT® forfieldbus control with 8 process data words.

Word Bit FunctionPI1 0-15 Reserved

PI2 0 Digital output DO00

1 Digital output DO01

2 Digital output DO02

3 Digital output DO03

4-15 Reserved

2673

3617

/EN

– 0

6/20

20

Page 43: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

11Process dataProcess data assignment

Manual – ALX0517 Application Module 43

Word Bit FunctionPI3 0 /Controller inhibit 0 = Enable

1 = Controller inhibit

1 Enable/rapid stop 0 = Rapid stop1 = Enable

2 Enable/stop 0 = Stop1 = Enable

3 Reserved

4 Reserved

5 Reserved

6 Fault reset

7 Reserved

8 Start

9 Jog+

10 Jog-

11 Mode 20 00 = Operating mode 0: Reserved01 = Operating mode 1: Jog mode10 = Operating mode 2: Referencing mode11 = Operating mode 3:Positioning mode/speed mode

12 Mode 21

13 Reserved

14 Releasing the brake without drive enable

15 Deactivate SWLS1) 0 = SWLS activated1 = SWLS deactivated

PI4 0-15 Target position (high word) [user-defined unit]

PI5 0-15 Target position (low word) [user-defined unit]

PI6 0-15 Setpoint speed [user unit]

PI7 0-15 Acceleration ramp [ms] for 0 – 1500 rpm

PI8 0-15 Deceleration ramp [ms] for 0 – 1500 rpm1) SWLS = software limit switch

2673

3617

/EN

– 0

6/20

20

Page 44: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

11 Process dataProcess data assignment

Manual – ALX0517 Application Module44

11.2.2 Process output dataThe following table shows the process output data from the MOVIFIT® to the PLC forfieldbus control with 8 process data words.

Word Bit FunctionPO1 0 Maintenance switch (mains OFF)

1 = Maintenance switch ON; 0 = Maintenance switch OFF

1 Undervoltage 24 V-S (sensor supply)1 = Undervoltage sensor supply0 = No undervoltage sensor supply

2 Inverter voltage not applied (24 V_P) (power section)1 = Inverter voltage not applied0 = Inverter voltage applied

3-6 Reserved

7 MOVIFIT® system fault

8 Overload actuator voltage DO00

9 Overload actuator voltage DO01

10 Overload actuator voltage DO02

11 Overload actuator voltage DO03

12 Overload voltage supply group 1

13 Overload voltage supply group 2

14 Overload voltage supply group 3

15 Overload voltage supply group 4

PO2 0-15 Digital input DI00-DI15

PO3 0 Motor running

1 Inverter ready

2 Drive referenced

3 Target position reached

4 PO data enabled1 = Process data of higher-level controller active(Exception: manual mode via MotionStudio)0 = Prioritized fixed setpoint control or "Control mode" (→ 2 32) ac-tive

5 Inverter fault

6 CW hardware limit switch

7 CCW hardware limit switch

8-15 Code for status/warning/error of the inverter1)

PO4 0-15 Actual position (high word) [user unit]

PO5 0-15 Actual position (low word) [user unit]

PO6 0-15 Actual velocity [user unit] 2673

3617

/EN

– 0

6/20

20

Page 45: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

11Process dataProcess data assignment

Manual – ALX0517 Application Module 45

Word Bit FunctionPO7 0-15 Output current [%] of IN of the inverter

PO8 0-15 Reserved1) For a detailed description, refer to the applicable documentation of the device.

2673

3617

/EN

– 0

6/20

20

Page 46: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

Index

IndexC

Clear velocity .......................................................  29Control mode.......................................................  32Copyright notice ....................................................  7Cycle diagram

Jog mode........................................................  15Positioning mode............................................  17Referencing mode ..........................................  16

D

Data managementDescription .....................................................  36Structure of process data ...............................  39

Decimal separator .................................................  6Diagnostics with the S12 safety option

Structure of process data ...............................  33Documents, applicable ..........................................  5Drive configuration ..............................................  22

E

Embedded safety notes.........................................  6Engineering software.............................................  9

F

Fieldbus address .................................................  22

G

Gear ratio, scaling parameters ............................  25

H

Hazard symbolsMeaning............................................................  6

L

Limit switch, monitoring .......................................  26

M

Monitor mode ......................................................  31Monitoring functions ............................................  26MOVITOOLS® MotionStudio..................................  9

Installation ......................................................  20

N

NotesDesignation in the documentation ....................  5

Meaning of the hazard symbols .......................  6

O

Operating mode...................................................  22Operating modes.................................................  10

P

Position monitoring, monitoring ...........................  26Process data assignment ....................................  42Process input data...............................................  42Process output data ............................................  42Product names ......................................................  7

R

Reference travel parameters...............................  29Rights to claim under limited warranty ..................  6

S

Safety notesBus systems .....................................................  8Designation in the documentation ....................  5Meaning of the hazard symbols .......................  6Preliminary information.....................................  8Structure of embedded.....................................  6Structure of section-related ..............................  6

Scaling parameters .............................................  25Search speed ......................................................  29Section-related safety notes..................................  6Setting the parameter set ....................................  22Signal words in safety notes..................................  5Software

Features .........................................................  10Requirements ...................................................  9

Starting the application module ...........................  20Startup

Preparation.....................................................  20

T

Target group..........................................................  8Terminal assignment ...........................................  40Terms of use .........................................................  6Timeout response................................................  22Trademarks ...........................................................  7

2673

3617

/EN

– 0

6/20

Manual – ALX0517 Application Module46

Page 47: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

Index

U Use, designated ....................................................  8

2673

3617

/EN

– 0

6/20

Manual – ALX0517 Application Module 47

Page 48: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents
Page 49: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents
Page 50: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents
Page 51: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents
Page 52: ALX0517 Application Module for MOVIFIT® FC – Function ...EtherNet/IP or Modbus TCP Fieldbus Interface Edition 06/2020 26733617/EN SEW-EURODRIVE—Driving the world Table of contents

SEW-EURODRIVE—Driving the world

SEW-EURODRIVE GmbH & Co KGErnst-Blickle-Str. 4276646 BRUCHSALGERMANYTel. +49 7251 75-0Fax +49 7251 [email protected]