ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 2
Index
Feeder Protection P3
Voltage & Frequency Protection P4
MotorProtection P5
Generator Protection P6
Distance Protection P7
Line & Cable Differential Protection P8
Phase Comparison Line Protection P9
Transformer Protection P10
Line Terminal IEDs Autoreclose
and Back-up for EHV/HVP12
Busbar Protection P11
Phasor Measurement Solutions P13
Accessory & Auxiliary Devices P14
Measurement Centres P15
Transducers P16
Disturbance Recorders P17
* Click on the product range for navigation
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
3/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 3
Feeder Protection
Selector
With voltage vectorShift & dynamic line rating
?
One box solutionWith mimic diagram
?
Autorecloserequired?
CheckSynchronism
Required?
Function keys forcontrol & test operations
Required?
8 binary inputs+8 relay contacts
Sufficient ?
P341Distributed Generation
Interconnection
Feeder Protection
C264PFeeder relay with
Integrated bay control
P145Feeder Management
Relay with autoreclose,
Check synchronism
& Function keys
P141Feeder management
relay
P142Feeder management
Relay with autoreclose
P143Feeder management
Relay with autoreclose
& check synchronism
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
No
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
4/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 4
Voltage & Frequency Protection
With IEC 61850Protocol?
Selector
No P941Voltage & Frequency
Management relay
8 binary inputs+8 relay contacts
Sufficient?
P943Voltage & Frequency
Management relay
Function keys forcontrol & test operations
required?
P145Feeder management relay
With auto-reclose, check
synchronism
& function keys
Yes
No
No
No
P141Feeder Management
relay
Yes
Yes
P143Feeder management relay
With auto-reclose
& Check synchronism
P142Feeder management relay
With auto reclose
Yes
Yes
No
START
16 binary inputs+14 relay contacts
Sufficient ?
Sum total of
binary I/O points requiredgreater than 23?
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
5/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 5
Motor Protection
Selector
P241Motor Management
relayIs motor rated
power 3 MW ?
Yes
P242Motor Management
relay
No
(> 3MW)
WithdifferentialProtection?
Yes
P243Motor Management
Relaywith Differential
No
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
6/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 6
Generator ProtectionSelector
Small generators(10MVA)
With
underimpedance,loss of fieldProtection?
With differential?100% stator
earth fault, pole slippingdead machine?
With 100%stator earth fault via low
frequency injection?
With 100% statorearth fault, pole slipping,
dead machine ?
With differential & 2x
neutral voltage inputs for earthfault and interturn
protection?
P341
P141
P343
P346Economy model
P342
P345
P344
Yes
No
No
Yes Yes
Yes
No
Yes
No
Yes
P346(With differential &
1 neutral voltage inputfor earth fault)
No
No
Yes
Yes
No
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
7/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 7
Distance Protection
TypicalCharacteristicPreference?
Sub-cycleDistance required?
Sub-cycle DistanceRequired?
Single-PoleTripping required?
8 Opto-inputs &
14 output contactsSufficient?
16 Opto-inputs &
21 output contactsSufficient?
Dual CircuitBreaker FeedingArrangement?
Single-PoleTripping required?
P445Economy distance
for Subtransmission
& DistributionP443Sub-cycle quad/mhoDistance relay with
Single-pole A/R
P446Sub-cycle dual CB
quad/Mho distance
Relay with single-pole
autoreclose
P444Distance relay with
Single pole A/R and
Extended I/O
P442Full-scheme quad.
Distance relay with
Single pole Recloser
P441Full-Scheme quad.
Distance for 3 Pole
Tripping
Mho
No
No
No
No
No
No
No
Quad
Yes
Yes
Yes Yes
Yes
Yes
Selector
START
Yes
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
8/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 8
Line and Cable Differential ProtectionSelector
Yes
No
No
With IEC61850 andFunction Keys?
Dual CBconfiguration?
Compatible withSDH/SONET networks?
With Voltage Inputs,Optional Distance
Protection?
No
No
Yes
Yes
Yes
More than 16 digital inputsand 14 output contacts?
P544Dual CB Differential with
Optional Distance
P546Dual CB Diff. / Distance
With Extended Binary I/O
NoYes
With Auto Reclose?
P541Economy Model
P542
No
More than 16 digital inputsand 24 output contacts?
P545Differential / Distance
With Extended Binary I/O
P543Differential with
Optional Distance
No
Yes
Yes
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
9/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 9
Phase Comparison Line ProtectionSelector
Yes
No
No
P547Phase Comparison with
8 binary inputs &
8 relay contacts in
40TE case
With FunctionKeys?
More than 8 digital inputsand 8 output contacts?
With IEC61850?
Application RequiresDistance Protection?
No
No
Yes
Yes
Yes
P547Advanced Model Phase
Comparison with Distance
in 80TE case
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
10/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 10
Transformer Protection Selector
3 winding
One
Auto
Transformer
Type of Transformer?
Both
2 winding
No
Yes
Is any windingSupplied by morethan 1 Circuit
Breaker?
P643
Dual Breaker feedingOne or both sides of
transformer?
P645
P643
Is any windingSupplied by morethan 1 Circuit
Breaker?
P645
No
Yes
With or withoutTertiary winding?
With
Is any winding
Supplied by morethan 1 Circuit
Breaker?
No
3 phaseVoltages required
for measurement, protection,Directionalising,
records? No
Yes
Without
Yes
START
P642Transformer Protect.
For 2-End Schemes
P643Transformer Protect.
For up to 3 Ends
P645Transformer Protect.
For up to 5 Ends
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
11/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 11
Busbar Protection Selector
START
TechnologyPreference?
Number of feeder,Coupler, and section
breakers
How manyDiscrete protection
Zones?
PreferredOperatingprinciple
NumericalRelay(s)
Required?
P746Busbar Differential for
Small Schemes
P74* SchemeP741 Central Unit
P742 Peripheral Unit
P743 Peripheral Unit
P14*Feeder Management
Relays Used in Interlock
(Blocking) Scheme
Low impedance
(Biased) High impedance
Economy
Distribution
Scheme
3 or
more
1 or 2
Up to
18
More
than
18
No
Yes
Current
Pickup
Voltage
Pickup
P145Feeder Management
Relay Used in High
Impedance mode
with Varistor
MCAG34High Impedance, Current
Calibrated Electro-
Mechanical Relay
MFAC34High Impedance, Voltage
Calibrated Electro-
Mechanical Relay
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
12/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 12
Line Terminal IEDs Autoreclose and Back-up forEHV/HV
Dual Circuit BreakerConfiguration ?
16 opto-inputs and14 output contacts
sufficient?
P841 model ASingle CB control, reclose,
Check synchronising and
back-up protection
P841 model BModel for dual breaker,
ring bus, and breaker
and a half feeding
No
No
Yes
Yes
Selector
START
UK Mesh CornerApplication ?
No
P842Mesh corner Autoreclose
Scheme for Three Pole
Tripping
Yes
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
13/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 13
Phasor Measurement Solutions
RequiredComponent
P594
GPS Synchronising Unit
S800 sPDCALSTOM Phasor
Data Concentrator
P847Phasor Measurement
Unit
GPS Time Synch. PMU
Phasor DataConcentrator
START
Selector
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
14/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 14
Accessory & Auxiliary Devices
DeviceRequired?
Automatic CTShorting Required?
Device FormFactor
Operating Principle
Required
Trip CircuitSupervision
Device?
Trip RelayRequired?
START
Selector
MVAJ
MVAX
MCAA
MVAAPRiMA
Plug-in Auxiliary Relays
and Timers
MMLG P991
Test
Block
Hinged Armature
Relay
Yes
Yes
YesNo
No
No
Plug-in 4U Rack
Current
Voltage
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
15/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 15
Measurement Centres
Selector
Class 1/0.5%or Class 0.5s/0.2%
accuracy?
Power QualityRecorder?
Do you requirecommunications ?
M2530.2% Power
Quality Analyser
M2430.2% Communicating
Measurement Centre
with Data Logger
Yes0.5%
Yes
0.2%
No
No
M2320.5% Communicating
Measurement Centre
M2120.5% Non-Communicating
Measurement CentreData RecorderRequired?
NoM233
0.2% Communicating
Measurement Centre
Yes
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
16/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 16
Transducers Selector
0.5% or 0.2%accuracy
?
Power QualityRecorder?
Mean or RMSMeasurements ?
I500 I5MQ0.2% Power
Quality Analyser
I500 I5ML0.2% single phase
Transducer with Data Logger
Mean0.5%
Yes
0.2%
Single
RMS
I400I4CA Current or
I4VA Voltage
I400Class 1 Non-Communicating
Transducers
Data Recorder?
No
I500 I5MT0.2% 3 Phase
transducer
Single Phase orThree Phase?
I500 I5MS0.2% single
phase transducer
Select by
Measurement
required
Single or Multifunction ?
I400I4M* range
Single
Multi
Single Phase orThree Phase?
Single
Three
I500 I5MR0.2% 3 Phase Transducer
with Data Logger
Three
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
17/18
ALSTOM 2010. All rights reserved. Information contained in this document is provided without liability for information purposesonly and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness ofinformation or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority,is strictly prohibited.
Product selector - 08.2010 - P 17
Disturbance Recorders
Selector
Number of Feeders?
YesTwo
More than 4digital inputs?
One
No
M571Single Line / Dual Bus
Monitoring & Recording IED
More than 4digital inputs?
Yes
No
M572Dual Line / Dual Bus
Monitoring & Recording IED
M871Single Line / Dual Bus
Monitoring & Recording IED
M872Dual Line / Dual Bus
Monitoring & Recording IED
START
7/29/2019 ALSTOM Grid SAS Product Selector August 2010 V5
18/18
www.alstom.com