Upload
tecnicoeem
View
54
Download
5
Embed Size (px)
DESCRIPTION
Public Address System Maual
Citation preview
1
TECHNICAL MANUAL - AlphaAnnounce
AlphaAnnounce PA System 2007 TYP 3 - HAV
2
Table of Contents
Table of Contents ....................................................................................................... 2
Key to numbers ......................................................................................................... 3
Module 1 – ................................................................................................................ 4
Module 1 ................................................................................................................... 5
Module 1 ................................................................................................................... 6
Module 2 and 3 .......................................................................................................... 7
Module 4 and 5 .......................................................................................................... 8
Module 6 ................................................................................................................... 9
Module 7 and 8 ......................................................................................................... 10
Module 9 and 10 ....................................................................................................... 11
Module 11 and 12 ..................................................................................................... 12
Module 13 and 14 ..................................................................................................... 13
3
Key to numbers
Module Description
1 Alarm call master panel
2 100 V Relay card
3 100 V / Signal Relay card
4 Amplifier monitoring
5 100V Relay card / General Alarm
6 Digital I/O card
7 Telephone interface / external control input
8 DAC Digital Announce Card
9 230V power supply / Battery switch
10 Back-up microphone
11 Back-up push button panel
12 DAC Digital Announce Card for the back-up system
13 Digital power amplifier 100V - 250 W / 500 W
14 Digital power amplifier 100V - 250 W / 500 W
4
Module 1 – Alarm call master panel (System status)
PC RS232 - PC connection for programming purpose
SYS Err. - General alarm. There is a system error
BUS act. - Data bus active. Data transfer is taking place
DSP1 - Led is on when microphone panel 1 is connected and ready to use
- Led blinks when microphone panel 1 is not connected or defective
DSP2 - Led is on when microphone panel 2 is connected and ready to use
- Led blinks when microphone panel 2 is not connected or defective
DSP3 - Led is on when microphone panel 3 is connected and ready to use
- Led blinks when microphone panel 3 is not connected or defective
DSP4 - Led is on when microphone panel 4 is connected and ready to use
- Led blinks when microphone panel 4 is not connected or defective
DSP5 - Led is on when microphone panel 5 is connected and ready to use
- Led blinks when microphone panel is not connected or defective
DSP6 - Led is on when microphone panel 6 is connected and ready to use
- Led blinks when microphone panel 6 is not connected or defective
5
Module 1 – Alarm call signal control ( Programme - Music)
Input 1 - Led is on when music input 1 is active
Input 2 - Led is on when music input 2 is active
Input 3 - Led is on when music input 3 is active
IN1 - Volume / Level music input 1
IN2 - Volume / Level music input 2
IN3 - Volume / Level music input 3
Level - Master volume of all music signals
LF - Low frequency – increase / decrease 80Hz +/- 12 dB
HF - High frequency – increase / decrease 8,000Hz +/- 12 dB
Level[dB] - Sound level indicator
6
Module 1 - Alarm call signal control – (Call / Alarm)
Level - Volume level adjustment of announcement
This control has no purpose for alarm signals from the DAC (module 8)
The volume of the alarm signal can be adjusted via the DAC (module 8)
LF - Low frequency - increase / decrease 80Hz +/- 12 dB
HF - High frequency - increase / decrease 8,000Hz +/- 12 dB
Level[dB] - Sound level indicator
ACTIVE - Led is on if one of the microphone panels is active or if there is an alarm
7
Module 2 and 3 – Relay card (Module 2 en 3)
Module 2
Rel. active LED 1 - LED on: Zone 1 active
Rel. active LED 2 - LED on: Zone 2 active
Rel. active LED 3 - LED on: Zone 3 active
Rel. active LED 4 - LED on: Zone 4 active
Rel. active LED 5 - LED on: Zone 5 active
Rel. active LED 6 - LED on: Zone 6 active
Module 3
Rel. active LED 1 - LED on: Zone 7 active
Rel. active LED 2 - LED on: Zone 8 active
Rel. active LED 3 - LED on: Alarm 1 active
Rel. active LED 4 - LED on: Alarm 2 active
Rel. active LED 5 - LED on: Alarm 3 active
Rel. active LED 6 - LED on: Alarm output active
8
Module 4 and 5 - Amplifier monitor (Module 4) – Relay card (Module 5)
Module 4
AMP1 - Green LED on = Amplifier OK. Red LED on = Amplifier defective
AMP2 - Green LED on = Amplifier OK. Red LED on = Amplifier defective
AMP3 - Green LED on = Amplifier OK. Red LED on = Amplifier defective
AMP4 - Green LED on = Amplifier OK. Red LED on = Amplifier defective
AMP5 - Green LED on = Amplifier OK. Red LED on = Amplifier defective
AMP6 - Green LED on = Amplifier OK. Red LED on = Amplifier defective
Module 5
Rel. active LED 1 - Amplifier 1 defective. The back-up amplifier will take over
Rel. active LED 2 - Amplifier 2 defective. The back-up amplifier will take over
Rel. active LED 3 - Amplifier 3 defective. The back-up amplifier will take over
Rel. active LED 4 - Amplifier 4 defective. The back-up amplifier will take over
Rel. active LED 5 - Amplifier 5 defective. The back-up amplifier will take over
Rel. active LED 6 - Amplifier 6 defective. The back-up amplifier will take over
9
Module 6 - Digital I/O Card - DIO16MS
Output 1 –8 (Red Led)
• Output led 1 on Zone 1 activated by Master System (Module 1)
Output led 1 blinking Zone 1 activated by back-up System (Module 10&11)
• Output led 2 on Zone 2 activated by Master System (Module 1)
Output led 2 blinking Zone 2 activated by back-up System (Module 10&11)
• Output led 3 on Zone 3 activated by Master System (Module 1)
Output led 3 blinking Zone 3 activated by back-up System (Module 10&11)
• Output led 4 on Zone 4 activated by Master System (Module 1)
Output led 4 blinking Zone 4 activated by back-up System (Module 10&11)
• Output led 5 on Zone 5 activated by Master System (Module 1)
Output led 5 blinking Zone 5 activated by back-up System (Module 10&11)
• Output led 6 on Zone 6 activated by Master System (Module 1)
Output led 6 blinking Zone 6 activated by back-up System (Module 10&11)
• Output led 7 on Zone 7 activated by Master System (Module 1)
Output led 7 blinking Zone 7 activated by back-up System (Module 10&11)
• Output led 8 on Zone 8 activated by Master System (Module 1)
Output led 8 blinking Zone 8 activated by back-up System (Module 10&11)
• Output led 12 on System Error active
• Output led 15 on System in use
Input LED 1 on Error from back-up system active (Module 10&11)
Input LED 2 on The back-up system (Module 10&11) is in use
In-Output LED 16 blinking Digital I/O Card DIO16MS (Module 5) active – OK
10
Module 7 and 8 – Telephone interface / signal input (Module 7) - DAC (Module 8)
Module 7
Pwr.[data] Led Blinks during active data transmission and Power OK
Error Led On: System failure
C/A Preset Led On: External Call input on this module is active
Prg. Preset Not in use
Level 1 Volume adjustment of telephone announcements
Level 2 Not in use
Level 3 Not in use
Rs 232 PC Interface / (Only for service)
Module 8
Power[data] Led Blinks during active data transmission and Power OK
Play Led On: message is playing
Blinking: testing message
Error Led On: SD card error / failure
Level 1 Volume Alarm 1
Level 2 Volume Alarm 2
Level 3 Volume Alarm 3
Level 4 Volume pre-announcement tone
Level 5 Not in use
Level 6 Not in use
11
Module 9 and 10 – Power supply (Module 9) - back-up microphone (Module 10)
Module 9
P Led on Power OK
E Led on Power failure / No battery connected
S Led on Standby (Not in use)
Module 10
Back-up microphone. This microphone has priority over the Master system.
By pushing the call button an announcement can be made in all zones at once.
This function will remain when the Master system fails.
12
Module 11 and 12 - Back-up push button field (Module 11) - Back-up DAC (Module 12)
.
Module 11
Push button 1 Activates Alarm 1
Push button 2 Activates Alarm 2
Push button 3 Activates Alarm 3
Push button 4 Stops an active alarm.
The back-up system always has priority over the master system.
Module 12
Power[data] Led On: Power OK
Play Led On: Message is playing
Blinking: Testing message
Error Led On: Sd card failure
Level 1 Volume alarm 1 (back-up system level)
Level 2 Volume alarm 2 (back-up system level)
Level 3 Volume alarm 3 (back-up system level)
Level 4 Not in use
Level 5 Not in use
Level 6 Not in use
13
Module 13 and 14 - Amplifier
Module 13 + 14
PS OK Led Power OK
Bat Error Led Battery failure
BAT active Led Amplifier operating on battery
SPK CON Loudspeaker wiring OK
Standby Led Not in use
GND Fault Earth loop on loudspeaker output determined
Error Amplifier failure / Overload
-30-20-10 dB Led Output Level indicator
Clip Led on Overload, entry level too high