3
ALCATEL-LUCENT 1830 PHOTONIC SERVICE SWITCH (PSS-32S, PSS-32 AND PSS-16) RELEASE 6.0 The Alcatel-Lucent 1830 Photonic Service Switch (PSS) supports next-generation WDM multiservice transport from access to core. The scalable 1830 PSS, with high-performance 100G transport, drives lower TCO and extends network life cycles. The 1830 PSS transforms traditional WDM into a flexible transport layer with managed agile photonics, multilayer switching and services, and network intelligence. The platform supports a wide range of applications and services such as Carrier Ethernet, mobile and broadband backhaul, multicast video, Data Center Interconnect and Cloud. With 1830 PSS platforms ranging from compact access to converged Optical Transport Network (OTN)/WDM core, operators can optimize multiservice networks to meet unpredictable traffic demands in the cloud services era. The Alcatel-Lucent 1830 PSS portfolio pro- vides terabit OTN switching and photonics capacities. The Photonic Service Engine (PSE) enables high-performance 100G and an evolutionary path to 400G transport. Leveraging an intelligent control plane and integrated data, control and management planes, the 1830 PSS simplifies network management for maximum multilayer performance and efficiency. The 1830 PSS is a multi-reach platform that spans access, metro, regional, and long-haul applications and supports a wide range of data rates, enabling service delivery in a variety of environments and applications: Broadband transport networks for telecom- munications operators and enterprises operating as Telcos to provide high- bandwidth connectivity over long distances up to 4,000 km Metropolitan or national research networks for sharing IP and Fibre Channel (FC) connectivity and enabling grid computing applications Campus networks for data center protec- tion or data sharing for private and public organizations, including universities, hospitals, banks and airports Multi-campus networks for long-distance cooperation among public and private organizations and optimization of leased dark fiber Support for the full range of network topologies, including ring, point-to-point and arbitrary optical mesh topologies KEY FEATURES A static, tunable/reconfigurable optical add/drop multiplexer (T/ROADM) with single wavelength add/drop granularity Colorless and any direction add/drop capabilities Up to 88 wavelengths and 50 GHz ITU WDM per fiber pair • Support for Generalized Multi-Protocol Label Switching (GMPLS) to further enhance network flexibility and improve resiliency with photonic restoration OTM-0.1 through OTM-0.4 interfaces and ODU0/1/2/2e/3/4/flex mapping/ multiplexing structures according to G.709 • 100-Gb/s and 40-Gb/s channel capacity, with best-in-class SD-FEC, Polarization Division Multiplexed Quadrature Phase- shift Keying (PDM-QPSK) coherent technology (100 Gb/s) and Polarization Division Multiplexed Binary Phase- shift Keying (PDM-BPSK) (40 Gb/s) to support upcoming traffic needs with no interference with existing 10 Gb/s channels deployed Support for optional Raman amplification for extended span application via integrated RAMAN or Hybrid (Raman/ EDFA) amplifiers GMPLS/ASON enabling cross-layer automation and highly available networks resilient to multiple failures with flexible restoration options 1830 PSS-32 1830 PSS-32S 1830 PSS-16

Alcatel-Lucent 1830PSS Datasheet

Embed Size (px)

DESCRIPTION

Datasheet for Alcatel-Lucemt 1830PSS

Citation preview

  • AlcAtel-lucent 1830 Photonic Service Switch(PSS-32S, PSS-32 And PSS-16)RELEASE 6.0

    The Alcatel-Lucent 1830 Photonic Service Switch (PSS) supports next-generation WDM multiservice transport from access to core. The scalable 1830 PSS, with high-performance 100G transport, drives lower TCO and extends network life cycles.

    The 1830 PSS transforms traditional WDM into a flexible transport layer with managed agile photonics, multilayer switching and services, and network intelligence. The platform supports a wide range of applications and services such as Carrier Ethernet, mobile and broadband backhaul, multicast video, Data Center Interconnect and Cloud. With 1830 PSS platforms ranging from compact access to converged Optical Transport Network (OTN)/WDM core, operators can optimize multiservice networks to meet unpredictable traffic demands in the cloud services era.

    The Alcatel-Lucent 1830 PSS portfolio pro-vides terabit OTN switching and photonics capacities. The Photonic Service Engine (PSE) enables high-performance 100G and an evolutionary path to 400G transport. Leveraging an intelligent control plane and integrated data, control and management planes, the 1830 PSS simplifies network management for maximum multilayer performance and efficiency.

    The 1830 PSS is a multi-reach platform that spans access, metro, regional, and long-haul applications and supports a wide range of data rates, enabling service delivery in a variety of environments and applications:

    Broadbandtransportnetworksfortelecom-munications operators and enterprises operating as Telcos to provide high-bandwidth connectivity over long distances up to 4,000 km

    Metropolitanornationalresearchnetworksfor sharing IP and Fibre Channel (FC) connectivity and enabling grid computing applications

    Campusnetworksfordatacenterprotec-tion or data sharing for private and public organizations, including universities, hospitals, banks and airports

    Multi-campusnetworksforlong-distancecooperation among public and private organizations and optimization of leased dark fiber

    Supportforthefullrangeofnetworktopologies, including ring, point-to-point and arbitrary optical mesh topologies

    Key feAtureS Astatic,tunable/reconfigurableoptical

    add/drop multiplexer (T/ROADM) with single wavelength add/drop granularity

    Colorlessandanydirectionadd/dropcapabilities

    Upto88wavelengthsand50GHzITUWDM per fiber pair

    SupportforGeneralizedMulti-ProtocolLabel Switching (GMPLS) to further enhance network flexibility and improve resiliency with photonic restoration

    OTM-0.1throughOTM-0.4interfacesandODU0/1/2/2e/3/4/flexmapping/multiplexing structures according to G.709

    100-Gb/sand40-Gb/schannelcapacity,with best-in-class SD-FEC, Polarization Division Multiplexed Quadrature Phase-shift Keying (PDM-QPSK) coherent technology (100 Gb/s) and Polarization DivisionMultiplexedBinaryPhase-shiftKeying(PDM-BPSK)(40Gb/s)tosupport upcoming traffic needs with no interference with existing 10 Gb/s channels deployed

    SupportforoptionalRamanamplificationfor extended span application via integratedRAMANorHybrid(Raman/EDFA) amplifiers

    GMPLS/ASONenablingcross-layerautomation and highly available networks resilient to multiple failures with flexible restoration options

    1830PSS-32

    1830PSS-32S

    1830 PSS-16

  • 2Alcatel-Lucent 1830 Photonic Service Switch (PSS-36, PSS-32 and PSS-16)AlcAtel-lucent DAtA sheet

    WavelengthTrackermonitorsand traces each wavelength at any point in the network including intra-nodal fiber connections allowing industry leading photonic OAM

    2TbpsODUkswitchingfabricdesignedtoenable flexible client service grooming and protection for metro and core applications with 11G and 130G SD FEC Line cards.

    Key benefitS T/ROADMtechnologyallowsoperatorsto

    provision and reconfigure wavelengths remotely while adding any-wavelength-to-anywhere flexibility to their network infrastructure enabling dynamic photonic layer for cloud architectures

    Flexiblegrid-readyOTSlineprovidesinvestment protection for carriers

    T/ROADM,opticalpathtracingandpowermonitoring reduces the overall complexity and cost of network wavelength manage-ment equivalent to managing SONET/SDHtraffic,makingiteasiertoengineer,implement and maintain networks

    Reducesoperatingexpenditures(OPEX)with a high-density, low-power per bit design

    Sophisticateddesigntoolsandself-tuning features simplify, optimize and accelerate planning for new networks or upgrades; these tools fully automate network installation, provisioning and commissioning, while unparalleled optical performance is guaranteed for the most stringent long-reach applications

    technicAl SPecificAtionS optical layer intelligence and wavelength tracker optical power management

    Opticallayerpathtracingandpowermonitoring on a per-unique-wavelength service basis

    Viewofallwavelengthspresentonaselected fiber pair

    Integratedfaultisolationandsectionalization at the optical layer

    Automatedopticallayerwithdynamicpower equalization

    Integratedfaultcorrelation

    Multi-degree t/roAdM and roAdM

    WSS-basedROADMtechnology Multi-degreenodesupport

    (up to 10 degrees)

    Multi-directionaladd/drop TunableMux/Demuxfornetwork

    traffic reconfiguration without on-site intervention

    Anydirection/colorlessconfigurations TerabitOTNswitching2TbpsODUkswitchingfabric 11G and 130G Line cards

    versatile range of client cards

    In-shelf convergence with photonic modules enables cost efficient start-up configurations

    De-coupling of client services and line cards saves Muxponder versions and reduces spare stock

    Increased resilience by electrical protection

    full range of service interfaces SONET:OC-3/-12/-48/-192/-768 SDH:STM-1/-4/-16/-64/-256 GigabitEthernet(GE),100GE,40GE,

    10 GE LAN and WAN, Fast Ethernet

    SONET/SDHmultiplexing OC-3/STM-1

    OC-12/STM-4 OC-48/STM-16

    Ethernetservices24xGbE/FEand 12xGbe/FEmodulesLayer2switchingcompliantwith MEF/CE2.0

    IEEE802.1adPBwithC&S-VLANtagprocessing

    MEF services E-line, E-LAN, E-Tree

    Sofisticated QoS processing

    EthernetOAM(IEEE802.3ah,802.1agandITU-TY.1731)

    IEEE802.1AXLAGandITU-TG.8032(v2)ERP protection

    Multicast services enhanced with IGMP snooping

    Synchronous Ethernet support

    G.8262EECOption1/2G.8264ESMC(EthSSM) Ethernet Demarcation Devices -

    smart SFP

    40Gb/sopticalinterfaces4x10Gb/sMUXOTnon-coherent:

    - Clientside:10GE,OC-192,STM-64 orG.709OTU2

    - Line support: Non-return-to-zero Differential Phase-shift Keying (NRZ-DPSK)modulation,100GHzchannel spacing

    4 x 10 Gb/s OT non-coherent:

    - Clientside:OC-768,STM-256,OTU3- Line support: P-DPSK modulation, 50GHzchannelspacing

    4x10Gb/sMUXOTcoherent- Lineside:CoherentPDM-BPSK 40Gb/s;50GHz(C-band)

    - Client side: 10 GE (LAN/WAN), OC-192/STM-64,OTU-2

    1 x 40G Add/Drop Coherent OT:

    - LineSideCoherentPDM-BPSK, 40Gb/sand50GHz(C-band)

    - Clientside:OC-768,STM256 100Gb/sopticalinterfaces

    130 Gb/s coherent SD FEC Line card; 50GHz

    10x10Gb/sMUXOTcoherent- Line side: Coherent PDM-QPSK 100Gb/s;50GHz(C-band)

    - Client side: 10 GE (LAN/WAN), OC-192/STM-64,OTU-2

    100Gb/sOT;coherent100Gb/s;50GHz- Line side: Coherent PDM-QPSK 100Gb/s;50GHz(C-band)

    - Client side: 100 GE, OTM-0.4

    Metro100GHighCapacityMuxpondercard (11 client ports):

    Lineside:4x28GbODB Client side: 10x 10GbE and 1x40GbE

    SAN:FC-100(1GFC),FC-200(2GFC),FC-400 (4G FC), FICON or FICON Express, FC-800(8GFC)andFC-1200(10GFC)

    UniversalencryptionmoduleprovidingAES256encryptiontodataplaneprocessed by 1830 PSS

    Transponderless(directconnect) transportofITU-gridwavelengths from external equipment

    InteroperablewithSONET/SDHAdd Drop Multiplexing (ADM) and optical cross-connects(OXCs),2Rand3Rtransport mode

    Pluggableinterfaces(SFP/XFP/SFP+/QSFP) Softwareconfigurable(CFP/SFP/XFP)

    SONET, GE and FC client interface

    SmartSFPEthernetDemarcationDevice(SFP with embedded Ethernet OAM engine)

  • www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright2013Alcatel-Lucent.Allrightsreserved.NP2013040766EN(June)

    GMPlS/ASon control plane Automatictopologydiscovery Autodiscoveryofservicesandresources WDM-optimizedpathcomputation Unconstrainedwavelengthpathsetup

    Routing over a feasible path

    Routing with regeneration definition

    Wavelengthpathreroutingwithwavelength path conversion

    Restoration Source-based restoration

    Protection restoration combined

    Nominalroute Operatorcontroloverconnection

    parameters

    Shuttingdownoflinks

    Scalability In-servicenetworkscalabilityfromone

    to hundreds of wavelengths without service disruption

    Optionalegressandingressbroadbandamplifiers

    Networkplanningindependentof traffic forecast

    flexible protection options Flexibleprotection/restorationoptions

    on a per-wavelength service basis

    Diverseroutedprotection Opticalchannel-dedicatedand

    shared-protection options

    1+1clientprotection OTSandOMSlevelphotonicprotection Fiber-levelfacilityprotection 1+1ODUkprotection

    integrated SlA support and monitoring

    Proactiveservicemanagement for wavelength services

    G.709compliant Flexibleservice-levelalarms EthernetservicesSLAmanagementutilizingIEEE802.3ah,801.agand ITU-TY.1731

    carrier class availability Delivers99.999%availability NEBSLevel3compliant Allcardshot-swappable Non-stopdistributed,reliable

    and scalable software architecture

    optical reach 4,000kmat10Gb/s 3,500kmat40Gb/s 3,500kmat100Gb/s

    network management Full-featuredoperations,administration,maintenanceandprovisioning(OAM&P)management functionality

    ManagementsupportforAlcatel-Lucent1350OpticalManagementSystem(OMS) 1340 Integrated Network Controller

    (INC)

    1354PhotonicManager(RM-PhM) NetworkmanagementinterfacesWebGUI CLI

    TL-1 and SNMP

    Networkmanagementaccess:Ethernetport(RJ-45)

    CraftinterfaceserialRS-232withDB-9connector

    Alcatel-LucentAdvancedEngineeringPlanning Tool simplifies network design and system installation

    SAn certification Brocadecertification EMCcertification IBMcertification(includingGDPS)

    Physical dimensions (PSS-16) Height:355.6mm(14in.) Width:483mm(19in.) Depth:300mm(12in.)

    Physical dimensions (PSS-32) Height:622mm(24.5in.) Width:483mm(19in.) Depth:300mm(12in.)

    Physical dimensions (PSS-32S) Height:748mm(29.4in.) Width:515mm(20.3in.) Depth:315mm(12.4in.)(including

    fan tray)

    optical amplifier Dual-stage,broadbanderbium-dopedfiber

    amplifiers

    Modularamplifieroptimizedforcoherenttransmission

    RAMANamplifier Veryhighpowerforlong-haulapplications(outputpower:+23dBm)

    Highpower(outputpower:+20dBm) Lowpower(outputpower:+17dBm) Mid-stageaccesssupportsDCUs Wavelengthrange:1530nmto1563nm

    (C-band)

    HybridRAMAN/EDFA(integratedRamanand modular EDFA amplifier)

    optical supervisory channel Selectablebitrates100Mb/sbidirectional100Base-FX155Mb/sbidirectionalOC-3/STM-1

    operating environment Power48VDCor115/240VAC

    (with external converter)

    400Wto1270Wpershelf Operatingtemperature:0Cto50C (32Fto122F)

    Shock/vibration:GR-63-CORE Humidity:5%to95%