Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunkingVertical or horizontal distribution system
Illustrations :page 13��1/�
Dimensions :pages 13��1/8 and 13��1/9
Illustrations :page 13��1/�
Dimensions :pages 13��1/8 and 13��1/9
Illustrations :page 13��1/�
Dimensions :pages 13��1/8 and 13��1/9
Illustrations :page 13��1/�
Dimensions :pages 13��1/8 and 13��1/9
Busbar system with metal casing (1)Rating Number of
tap-off outlets (100 mm pitch)
Polarity Reference Weight
kg
400 A 3� (16 on each side) 3-pole AK3-JB43 �5.000
3-pole + N AK3-JB44 30.000
800 A 3� (16 on each side) 3-pole AK3-JB83 40.000
3-pole + N AK3-JB84 50.000
Disconnect blocks (2)Supplied fitted with AK3-SBp supports for mounting AK3-PLp pre-slotted plates
Rated thermal current
Polarity Number of 100 mm modules
Reference (4) Weight
kg
125 A 3-pole + N + PE 1 AK3-BS141 1.500
� AK3-BS142 �.000
3 AK3-BS143 �.500
250 A (3) 3-pole + N + PE � AK3-BS242 3.000
3 AK3-BS243 3.500
Slotted mounting platesSupplied with screws for fixing onto AK3-SBp supports (included with AK3-BSppp disconnect block or for use without disconnect block - see page 13��1/4). This corresponds to one tap-off outlet module.
Application Suitable for fixing on
Number of 100 mm modules
Reference Weight
kg
For mounting equipment
AK3-BS141 or AK3-SB1 1 AK3-PL1 0.350
AK3-BS142 or AK3-SB2 � AK3-PL2 0.800
AK3-BS242 � AK3-PL2M 0.680
AK3-BSp43 or AK3-SB3 3 AK3-PL3 1.�50
Operating keyApplication Sold in
lots ofUnit reference
Weightkg
Ensures operation of the disconnect block stab connectors (key can only be withdrawn in position “O” or “I”)
5 AK3-DM1 0.0�8
(1)TheprotectiveconductorPEisnormallyprovidedbythemetalbusbarcasing.(2)Visiblebreakisolation.Padlockingfacilityforupto3padlocksinthedisconnectedposition.Atestdeviceincorporatedinthedisconnectblocksallowstestingofthecontrolcircuitintheisolated position (when early break auxiliary contact block(s) have been fitted).(3)The250Adisconnectblocksaremadeupusingtwo125Adisconnectblocks,mechanically
interlockedwithasingleoperator.(4) Marine specification: ‘Marine’ specification as standard. It is essential to use extra lateral
supportforthemountingplate(seepage13221/5).
References
13��1-EN_Ver5.0.indd
4
Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunkingAccessories for assembly by the user (to be ordered separately)
Mounting plate supports (1) without disconnect block Application Number of
100 mm modulesReference Weight
kg
For mounting pre-slotted plate AK3-PLp with depth adjustment.Supplied with necessary accessories for fitting onto the busbar system.
1 AK3-SB1 0.700
� AK3-SB2 1.�00
3 AK3-SB3 1.700
Mechanical interlock device (2)Application Can be used with Reference Weight
kg
Prevents on-load disconnection when associated with - an integral 18, 3� or 63 contactor breaker or - a GV3 motor circuit breaker
Integral 18, 3�, GV3 AK3-DV1 0.080
Integral 63 AK3-DV2 0.180
Auxiliary contact
For early breaking of the control circuit and ensuring off-load disconnection (1 or 2 contacts may be fitted)For signalling either the “On” or the “Off” state of the disconnect block (1 contact only may be fitted)
b
b
XC1-ZP2005 0.040
Protective cover for busbar headDescription Application Reference Weight
kg
Cover consisting of 2 identical parts; the distance between these parts can be adjusted according to the busbar rating.
CMD 400 A, CMD 800 A AK3-XCP 0.630
Special protective earth conductor
25 x 2 mm copper bar with rounded edges for fixing by rivets or nuts and bolts at the appropriate positions along the busbar run
AK3-XT4 0.730
Insulated busbar support blocks (3)DescriptionApplication
Permissible current (4)
Number and c.s.a. of copper bars per phase
Sub-assembly reference
Weight
A mm kg
Sub-assembly comprising 3 identical insulated busbar support blocks and fixing screws for the assembly of a horizontal busbar system by the user (busbars not supplied).
600 1 x 50 x 5 AK3-XS05 1.600
880 1 x 50 x 10 AK3-XS10 1.450
1080 2 x 50 x 5 AK3-XS05 1.600
1580 2 x 50 x 10 AK3-XS10 1.450
(1)ThemountingplatesupportcanaccommodatetheAK3-CF2Cadditionalfrontplate(seepage13221/7).
(2) This device does not exist for either GV2 or integral LD4: for these products, use a contact blockreferenceXC1-ZP2005.
(3)ThesearecompatiblewithAK2-CB200andCP200protectivecovers(seepage13211/4),clip-on fixing or clip-on + Ø 6 screw (not supplied).
(4)Permissiblepeakcurrentaccordingtodistancebetweentheinsulatedsupportblocks.
AK3-SB2
AK3SB2PL2-PRO-3-B
AK3-PL2AK3-SB2
AK3SB2PL2-PRO-3-B
AK3-PL2
L2L3
N
L1
XC1-ZP2005
L2L3
N
L1
XC1-ZP2005
AK3-XCP
AK3XCPXT4-PRO-3-B
AK3-XT4
AK3-XCP
AK3XCPXT4-PRO-3-B
AK3-XT4
AK2-CB200AK2-CP200AK2-CB200AK2-CP200
Dimensions :pages 13��1/8 and 13��1/9Dimensions :pages 13��1/8 and 13��1/9Dimensions :pages 13��1/8 and 13��1/9Dimensions :pages 13��1/8 and 13��1/9
References
13��1-EN_Ver5.0.indd
5
Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunkingAccessories (to be ordered separately)
For extra lateral support of mounting plate (1) Description Sold in
lots ofUnit reference
Weightkg
Vertical support for use with end fixing bracket
1 TA5-XB02 3.450
End fixing brackets (adjustable depth) for use on pre-slotted mounting plates
1 x 100 mm module
� AK3-XF1C 0.100
2 x 100 mm modules
1 AK3-XF2C 0.�00
3 x 100 mm modules
1 AK3-XF3C 0.300
1/4 turn screw + clip-in clasp for fixing bracket AK3-XFpC on the vertical support
10 AK3-XM1T 0.085
Locating peg for vertical positioning of the tap-off outlet
10 AK3-XM1P 0.095
Supply to control circuitsDescription Reference Weight
kgLot of 4 busway supports(designed to take 1 to 3, 2-pole busways)
TB5-XB03 0.750
2-pole busway(length � m, for cutting to length by the user)
TA5-XB05 0.400
For fixing 1 5 4 mounting rails(2)
Description Sold in lots of
Unit reference
Weightkg
Support (3) for 1 mounting rail(adjustable depth)
�0 AK3-XS01 0.050
Support (3) for 3 mounting rails 10 AK3-XS02 0.1�0
Partition fixing accessories (horizontal and rear)Description Sold in
lots ofUnit reference
Weightkg
Self-tapping screws Ø 4 x 8 mm 100 AK3-XV48 0.00�pushing waste material towards the outside (avoids getting swarf inside the equipment)
Ø 4 x 15 mm 100 AK3-XV415 0.00�
(1) For use when increased mechanical rigidity is required: panels subjected to vibration, tap-offs incorporatingheavyproducts.(2)Mountingrails(tobeorderedseparately)forinstallingterminalblocksorcomponentsofvaryingdepths.Mounting rail fixed on support by means of Ø 4 x 15 mm self-tapping screws, fixing centres: 82.5mm(1module),182.5mm(2modules),282.5mm(3modules).Maximum length of mounting rail: 93 mm (1 module), 193 mm (2 modules), 293 mm (3 modules).(3) Support fixed on mounting plate by rivets or Ø 4 mm nuts/bolts (not supplied).
AK3-XM1P
AK3-XM1T
TA5-XB02
AK3-XM1P
AK3-XM1T
TA5-XB02
TA5-XB05
TB5-XB03
TB5XBTA5XB-PRO-3-M
TA5-XB05
TB5-XB03
TB5XBTA5XB-PRO-3-M
2 x AK3-XV415 AK3-XS01
AK3XS01XV415-PRO-3-B
2 x AK3-XV415 AK3-XS01
AK3XS01XV415-PRO-3-B
6 x AK3-XV415
AK3-XS02
AK3-XF1C
AK3X1CXS02XV415-PRO-3-B
6 x AK3-XV415
AK3-XS02
AK3-XF1C
AK3X1CXS02XV415-PRO-3-B
Dimensions :pages 13��1/8 and 13��1/9Dimensions :pages 13��1/8 and 13��1/9Dimensions :pages 13��1/8 and 13��1/9Dimensions :pages 13��1/8 and 13��1/9
References
13��1-EN_Ver5.0.indd
6
AK3-CA1
3 x AK3-XV48
AK3-CA2
4 x AK3-XV48
AK3-CH1
AK3-CF1D
8 x AK3-XV48
AK3-XS1CF
AK3-CF1P
2 x AK3-XV415
2 x AK3-XV415
AK3-CF2C
AK3-CF2P
AK3-CF2D6 8 x AK3-XV48
AK3-CH1
AK3-CH1 AK3-CH1
AK3-XS2CF
AK3-CF2D
AK3-ASS-3-Q 13��1-EN_Ver5.0.indd
7
Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunkingPartitioning accessories for assembly by the user (to be ordered separately)
Front plates (1) colour beige RAL 7032For use on Cut-out Sold in
lots ofUnit reference
Weightkg
1 x 100 mm module Without � AK3-CF1P 0.430
With � AK3-CF1D 0.390
2 x 100 mm modules Without 1 AK3-CF2P 0.840
With (for integral 18 and 3�)
1 AK3-CF2D 0.740
With (for Integral 63)
1 AK3-CF2D6 0.740
3 x 100 mm modules Without 1 AK3-CF3P 1.�30
With (for integral 18 and 3�)
1 AK3-CF3D 1.110
With (for Integral 63)
1 AK3-CF3D6 1.110
With (for Integral 63 reverser)
1 AK3-CF3D66 1.110
Front plate supports (2)1 x 100 mm module – � AK3-XS1CF 0.�30
2 x 100 mm modules – 1 AK3-XS2CF 0.450
3 x 100 mm modules – 1 AK3-XS3CF 0.670
Additional front plate (3)Description Sold in
lots ofUnit reference
Weightkg
For use with AK3-SBp mounting plate supports or disconnect blocks AK3-BS142, BS143 or BS243
1 AK3-CF2C 0.060
Horizontal partitioning (4)
Can be mounted at top or bottom, by inverting � AK3-CH1 0.7�0
Rear partitioning (5)Foruse on
Sold in lots of
Unit reference
Weightkg
1 x 100 mm module � AK3-CA1 0.5�0
2 x 100 mm modules 1 AK3-CA2 1.000
3 x 100 mm modules 1 AK3-CA3 1.480
(1)Preventsaccessfromthefronttotheinsideoftheassembly.Canbeusedtomountcontrolandsignallingunits.Frontplateswithcut-out(width45mm)aredesignedtoaccommodatetheoperatingknobofflush-mounting products.Fixed to the front plate support by 2 Ø 4 x 15 mm self-tapping screws (see page 13221/5) and 1 Ø 5 mm nut/bolt (not supplied).(2) Pre-fitted with fixing bracket AK3-XFpC.Forusewithfrontplateorhorizontalpartitioning.Fixed by rivets or Ø 4 mm nuts/bolts, not supplied.(3)Fixingscrewssupplied.(4) Fixing by Ø 4 x 8 mm self-tapping screws (see page 13221/5).(5) Can be used to mount components. Pre-fitted with end brackets. Fixing by Ø 4 x 8 mm self-
tappingscrews(seepage13221/5).
Illustrations :page 13��1/6
Dimensions :pages 13��1/8 and 13��1/9
Illustrations :page 13��1/6
Dimensions :pages 13��1/8 and 13��1/9
Illustrations :page 13��1/6
Dimensions :pages 13��1/8 and 13��1/9
Illustrations :page 13��1/6
Dimensions :pages 13��1/8 and 13��1/9
References
13��1-EN_Ver5.0.indd
8
Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunking
Busbars with metal casing 1, 2 or 3 module tap-off outlet with pre-slotted plate attached AK3-JBpp AK3-BSppp + AK3-PLp
AK3- a a1 Tap-off b b1 g Usable length formounting componentsJB4p 503 443 1 module 94 8�
JB8p 536 459.5 2 modules 194 18�3 modules �94 �8�
1, 2 or 3 module tap-off outlet with accessoriesAK3-CA1 + AK3-XS1CF + AK3-CF1P + AK3-XS02 (viewed from above)Operating key fitted: AK3-DM1
AK3- a G Tap-off H (1) Interlock for a1JB4p 54 466 1 module 5� 1 x Ø 6.6 integral 18/32 (1 way) 33JB8p 70.5 48�.5 2 modules 15� 2 x Ø 6.6 integral 18/32 (2 way) 30
3 modules �5� 2 x Ø 6.6 integral 63 (1 way) 79AK3- a a1 a� a3 G g 16 tap-offs on each (1) 2 or 3 module tap-off outlet, 2 x Ø 6.6 holes on 100 mm centres integral 63 (2 way) 100JB4p 1�1 60 57 64 100 side of the trunking (2)Probetravel GV3- 43JB8p 154 93 90 97 133 on 100 mm pitch (3) Ø 3.5 hole for M4 screw, length 15 mm max.
a1
II
II
2xØ10
a
GII II
a2
1818
Ø13
Ø1336
70
120
1650
1680
2xØ10 II
II
8
47 76 47 23
67
118
5010
0
100★
100★
196
a1
II
II
2xØ10
a
GII II
a2
1818
Ø13
Ø1336
70
120
1650
1680
2xØ10 II
II
8
47 76 47 23
67
118
5010
0
100★
100★
196
a
a1
10
1
II
II220★
295★
b1 b
a
a1
10
1
II
II220★
295★
b1 b
a1
(2) 18
46
(1)
21H
26
G
1819
19
(3)
110
10
35 45 13
4075
25
195
232
232
50a
a1
(2) 18
46
(1)
21H
26
G
1819
19
(3)
110
10
35 45 13
4075
25
195
232
232
50a
References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7
Dimensions
13��1-EN_Ver5.0.indd
9
Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunking
Protective cover for busbar head Insulated busbar support blocksAK3-XCP (1) AK3-XS05, XS10
a gAK3-XS05 5.5 8
(1)Comprising2identicalparts. AK3-XS10 10.5 8
244
2xØ5,5
146,5
157,542 44,5
50 59,5
59,5
14
250
a3
33 15,5
2xØ5,5
244
2xØ5,5
146,5
157,542 44,5
50 59,5
59,5
14
250
a3
33 15,5
2xØ5,5
Ø6,5
155
a a a a
M6
★
IIII
150
★
a a★ a ★ a
59
220 15
170
II II
IIII 30
50
a ★AK3-XS05 5,5 8AK3-XS10 10,5 8
IsolateursAK3-XS05, XS10
Ø6,5
155
a a a a
M6
★
IIII
150
★
a a★ a ★ a
59
220 15
170
II II
IIII 30
50
a ★AK3-XS05 5,5 8AK3-XS10 10,5 8
IsolateursAK3-XS05, XS10
References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7
Dimensions(continued)
13��1-EN_Ver5.0.indd
10
Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunking
Mounting of tap-off outlet on the busbar
Positioning of mounting plate using front plate and/or mechanical interlock
(1)for GV2-P: 535x15(2)for GV3: 735x7.5
43
10
79
6 28
5
10
11
1
511
1023
4
6
7
27 42
89
20,5 26435 20,5229
==
27 42
Montage des départs sur la canalisation
43
10
79
6 28
5
10
11
1
511
1023
4
6
7
27 42
89
20,5 26435 20,5229
==
27 42
Montage des départs sur la canalisation
integral 18, 32 integral 63
(1)
(2)
GV2-P GV3integral 18, 32 integral 63
(1)
(2)
GV2-P GV3integral 18, 32 integral 63
(1)
(2)
GV2-P GV3integral 18, 32 integral 63
(1)
(2)
GV2-P GV3integral 18, 32 integral 63
(1)
(2)
GV2-P GV3integral 18, 32 integral 63
(1)
(2)
GV2-P GV3
References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7
Mounting
13��1-EN_Ver5.0.indd
11
Power distribution in control panels 0 CMD® prefabricated plug-in busbar trunking
Possibilities for mounting Integral 18, 32 or 63 on AK3- mounting plate
Integral 18integral LD1-LB030 + LD5-LB130 +Block of 5 contacts LA1-LB015 + LA1-LB015 +Block of 1 contact LA1-LB001 + LA1-LB001 +Block of 2 contacts LA1-LB031 –Block of 5 contacts – LA1-LB021 +Block of 1 contact – LA1-LB001
p Mounting possibleMounting on plate AK3- PL1 PL2 PL3 PL1 PL2 PL3With top partition (1) p p p – p p
With front plate p p p – p p
Number of modules occupied 1 � 3 – � 3Fixing hole reference numbers (1) 10 10 10 – 11 11
Integral 32 Integral 63integral LD1-LCp30 + LD1-LC040 + LD5-LC130 + LD5-LC130 + LD1-LDp30 + LD5-LD130 +Block of 6 contacts LA1-LC010 + LA1-LC010 + LA1-LC010 + LA1-LC010 + LA1-LC010 + LA1-LC010 +Tripping device LA1-LC07p + LA1-LC07p + LA1-LC07p + LA1-LC07p + LA1-LC07p + LA1-LC07p +Reset device LA1-LC05p (2) LA1-LC05p – LA1-LC05p + LA1-LC05p LA1-LC05p +Block of 3 contacts – – LA1-LC021 LA1-LC021 – LA1-LC021
p Mounting possible
Mounting on plate AK3- PL1 PL2 PL3 PL1 PL2 PL3 PL1 PL2 PL3 PL1 PL2 PL3 PL1 PL2 PL3 PL1 PL2 PL3With top partition (1) – p p – p p – p p – – p – p p – – p
With front plate – p p – p p – p p – – p – p p – – p
Number of modules occupied � � 3 � � 3 – � 3 – 3 3 – � 3 – 3 3Fixing hole reference numbers (1) 1 � � 1 �+3 �+3 – �+4 �+4 – �+4 �+4 – 6+7 6+7 – – 8+9(1) By using the fixing holes indicated, the bottom partition and AK3-DV1 mechanical interlock device can be fitted if necessary.(2) If reset device LA1-LC05pisnotrequired,mountingonplateAK3-PL1ispossiblewithtoppartitionandfrontplate.Thenumberofmodulesoccupiedis1.
References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7References :pages 13��1/3 to 13��1/7
Mounting(continued)
13��1-EN_Ver5.0.indd