FLOW EZY AIR SENTRY® DESICCANT TANK BREATHERS & IN-LINE FILTER-DRYERS INFORMATION BROCHURE Flow Ezy Air Sentry® Breathers are used worldwide in major industrial, mining, military, power generation, and fluid storage applications. They remove water, solid particles, and other contaminants from air being breathed into reservoirs, transformers, storage tanks, and gear- boxes. The service life of equipment and fluids is greatly extended when protected by a Flow Ezy Air Sentry® breather. See the enclosed brochure for all the Flow Ezy Air Sentry® desiccant and activated carbon breathers and in-line filter-dryers. FLOW EZY FILTERS, INC. P.O. Box 1749 Ann Arbor, MI 48106 phone 800-237-1165 or 734-665-8777 fax 800-252-1730 or 734-665-4332 e-mail: [email protected] web address: www.flowezyfilters.com Rev. 1, 2/2004

Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

Embed Size (px)

Citation preview

Page 1: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

FLOW EZY AIR SENTRY® DESICCANT TANK

BREATHERS & IN-LINE FILTER-DRYERS INFORMATION BROCHURE

Flow Ezy Air Sentry® Breathers are used worldwide in major industrial, mining, military, power generation, and fluid storage applications. They remove water, solid particles, and other contaminants from air being breathed into reservoirs, transformers, storage tanks, and gear-boxes. The service life of equipment and fluids is greatly extended when protected by a Flow Ezy Air Sentry® breather. See the enclosed brochure for all the Flow Ezy Air Sentry® desiccant and activated carbon breathers and in- line filter-dryers.

FLOW EZY FILTERS, INC. P.O. Box 1749

Ann Arbor, MI 48106 phone 800-237-1165 or 734-665-8777

fax 800-252-1730 or 734-665-4332 e-mail: [email protected]

web address: www.flowezyfilters.com

Rev. 1, 2/2004

Page 2: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

Flow Ezy A ir Sentry® Breathers replace the standard breather cap or vent tube on a tank or reservoir. They are easy to install using one of several adapters designed for different applicat ions. When the fluid in the system is lowered, or pressure changes occur, air is drawn in through openings under the breather cap. First, a ir passes through a fine, 2 micron solid particle filter. The air then passes through a diffuser to ensure maximum effect iveness within the silica gel chamber. Next, water vapor is removed as the air travels through a bed of silica gel - the highest capacity adsorbent avail-able. After being dried, the air passes through a second 2 micron solid partic le filter and enters the reservoir CLEAN AND DRY! Flow Ezy Air Sentry® Breathers use a three-stage filtration design to ensure optimum protection by removing wa-ter vapor and solid contaminants before they enter the fluid system. Flow Ezy Air Sentry® Breathers are patented in the United States. Key Benefits • Protects Expensive Equipment • Increases Operation Efficiency • Reduces Maintenance Costs Operational Features Bi-Directional Air Flow - Air entering is cleaned and dried. Expelled air partia lly regenerates the silica gel and "back flushes" the particulate filter to prolong the life of the breather. Durable Construction - Air Sentry® is manufactured from rugged ABS p lastic and impact-modified Plexig las. Water Vapor Adsorbent - The Silica Gel used in Air Sentry® breathers is chemically inert, non-corrosive, and conforms to all regulated toxicity standards in the U.S. and other countries. Microscopic pores allow the silica gel to adsorb up to 40% of its own weight. Color Indicator - When maximum adsorption is reached, the silica gel turns from gold to dark green to indicate that replacement of the breather is required. Activated Carbon - As air is expelled from the tank, it passes through activated carbon which removes oil vapors, fumes and odors. Safety Sealed - Seals keep moisture from entering the units until they are placed in service. They are easily re-moved without tools or sharp instruments.

Page 3: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

PAGE

Standard Desiccant Tank Breathers ("D" Series) 1-2

Fluid Transfer Test Results 3

Mini Contamination Control Breathers ("Z" Series) 4

5

By-Pass Adapter For Desiccant Tank Breathers 5

Removable Contamination Control Breathers ("R" Series) 6

Steel Desicc ant Tank Breathers ("M" Series) 7

In-Line Filter Dryers ("L" Series ) 8

Gas Neutralization Breathers ("GNS" Series) 9

Activated Carbon Tank Breathers ("D" Series) 10

Activated Carbon Capacity Index Chart 11

Desiccant Tank Breather Technical Specifications 12-13

Listing of Indus tries and Markets Where Desiccant Tank Breathers Are Used 14-15

Frequently Asked Questions 15-16

Application Photos 17

INDEX

Contamination Control Breathers w/ 2 Check Valves ("X" Series )

Page 4: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“D” SERIES CONTAMINATION CONTROL

TANK BREATHERS for enclosed fluid systems

RESERVOIRS—GEARBOXES—TRANSFORMERS—STORAGE

In any reservoir containing flu ids or semi-solids, air is breathed in and out as the flu id level changes or as thermal expansion and contraction occurs. Flu id contamination is the primary cause of component wear and lubricant failure in industrial equipment. Flow Ezy Air Sentry® replaces the standard breather cap or vent tube on a tank or reservoir. They are easy to install using one of several adapters de-signed for different applications.

When the fluid in the system is lowered, or pressure changes occur, air is drawn in through openings under the breather cap. First, air passes through a fine, 2 micron solid particle filter. The air then passes through a diffuser to ensure maximum effectiveness with the silica gel chamber. Next, water vapor is removed as the air travels through a bed of silica gel—the highest capacity absorbent avail-able. After being dried, the air passes through a second 2 micron solid particle filter and enters the reservoir CLEAN AND DRY! Flow Ezy Air Sentry® Breathers use a three stage filtrat ion design to ensure optimum protection by removing wa-ter vapor and solid contaminants BEFORE they enter the fluid system.

PERFORMANCE SPECIFICATIONS

Nominal Air Flow Rate 35 cfm Equivalent of 260 gpm of fluid volume change

Solid Contaminant Filtration Level 2 micron, 100% efficiency @ 35 cfm air flow

Solid Contaminant Filtration Surface Area 20.6 cubic inches

Operating Temperature Range -20° to 200° F

Silica Gel: Absorption Lowest Operational Dew Point

Up to 40% of its weight in water -100° F

Chemical Resistance Resistant to alkalis, hydrocarbons, non-oxidizing acids, salt water, and mineral or synthetic oils

OPERATION FEATURES BI-DIRECTIONAL AIR FLOW—Air entering is cleaned and dried. Ex-pelled air part ially regenerates the silica gel and “backflushes” the particulate filter to prolong the life of the breather. DURABLE CONSTRUCTION—Flow Ezy Air Sentry® is manufactured from rugged ABS plastic and impact-modified Plexig las. WATER VAPOR ABSORBENT—The silica gel used in Flow Ezy Air Sen-try® breathers is chemically inert, non-corrosive and conforms to all regu-lated toxicity standards in the U.S. and other countries. Microscopic pores allow the silica gel to absorb up to 40% of its own weight. COLOR INDICATOR—When maximum absorption is reached, the silica gel turns from gold to dark green to indicated the replacement of the breather required.

1

Page 5: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

37 74 112 149 187 224 261 299

1.0 25

0.8 20

0.6 15

0.4 10

0.2 5

0.0 0

5 10 15 20 25 30 35 40SC F M

GP M

FLOW RATE VS. PRESSURE DROP

All Flow Ezy Air Sentry® Disposable Models exh ibit the same flow rate charac-teristics.

APPLICATION GUIDE

MODEL NO.

HEIGHT (A)

DIAMETER (B)

CLEARANCE (C)

UNIT WEIGHT

MAXIMUM WATER

CAPACITY

D-100 3” 5” 1.25” 1.3 lbs. 0.2 lbs.

D-101 5” 5” 1.25” 1.9 lbs. 0.4 lbs.

D-102 8” 5” 1.25” 3.3 lbs. 0.9 lbs.

ADAPTER SELECTION GUIDE

The Flow Ezy Air Sentry® product line also includes other breather models that contain fume and odor removing material. Steel construction models are available for very corrosive and high temperature applications with air flow rates up to 300 cfm. Contact Flow Ezy for more informat ion. The D-108 is a disposable breather for larger applications. It has a 2” male npt pipe thread and designed for air-flow requirements up to 100 cfm which is the equivalent of 750 gpm of flu id volume change. It also operates at less than 1 psid. The overall height is 11 1/4” and the outer diameter is 5”. The D-109 is an even larger breather. This breather has a replaceable cartridge (p/n A-117). The D-109 has a 3” male npt connection and designed for air flow requirements of up to 250 cfm which is the equivalent of 1875 gpm of fluid volume change. It operates at less than 1 psid. The overall height is 15.5” and the outer diameter is 6”.

B

A

C

2

Page 6: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

Test: Two clean containers were filled with hydraulic fluid and fitted with Flow Ezy Air Sentry® Breathers. Two more containers were set up with the same configurations, except using stan-dard breather caps with screen filters. The fluid was pumped back and forth between the con-tainers, causing air to be breathed in and out of each drum. Both units were subjected to the same atmosphere and were filled with the same batch of hydraulic oil. The atmosphere con-tained low levels of moisture and high levels of particulate. Both systems were run for six months at the same pumping rate. The test was controlled and supervised entirely by laboratory personnel. Results: The count of solid particles, 5 micron or larger, in the new fluid in both containers at the begin-ning of the test was approximately 500 parts per milliliter. At the end of the six month test, the count in the containers protected by Flow Ezy Air Sentry® Breathers was 786. The count in the containers fitted with standard breather caps was 1,854 particles per milliliter, an increase of 265%; a significant difference in the entrance of abrasive contaminants, which would result in longer fluid life and less wear on the components serviced by the fluid. The water content in the containers fitted with standard breather caps went down during the six months test from 2.14 parts per million to 1.44 parts per million, an improvement of 33%. The moisture content in the containers protected by the Flow Ezy Air Sentry® Breathers dropped from 3.73 parts per million to 0.79, an improvement of 79%. This dramatically lower water content in fluid systems helps prevent fluid breakdown and oxidation, reduced lubricating film thickness, corrosion, accelerated metal fatigue, or loss of dielectric strength in insulating fluids.

FLUID TRANSFER TEST RESULTS Flow Ezy Air Sentry® Breather D-102 vs. Standard Breather Cap

300%

250%

200%

150%

100%

50%

0%

PARTICULATE INCREASE

Incr

ease

in

Part

icle

s G

reat

er

Than

5 M

icro

ns (

%)

Flow EzyA ir Sentry®

Std.Breather

100%80%

60%40%

20%0%

-20%-40%

-60%-80%

-100%

Moi

stur

e (%

)

M OISTURE REDUCTION

Flow EzyA ir Sentry®

-80%

Std.Breather

-33%

3

Page 7: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“Z” SERIES MINI CONTAMINATION CONTROL BREATHERS

PROTECTS GEARBOXES & SMALL HYDRAULIC RESERVOIRS

Most gearboxes and small hydraulic reservoirs have a simple breather/filler cap that allows air to be breathed in and out as fluid levels change or temperatures in -crease or decrease. Standard breather caps do not stop water vapor and other harmful contaminants from entering the system. Air Sentry® does! Air in industrial environments contain abrasive solid particles and humid ity. As the system temperature changes, the humid air forms condensation inside the gearbox o r reservoir. This moisture decreases fluid and lubricant effectiveness, and reduces their service life . Particulate contamination, mixed with the system’s flu id or lubricant, acts as an abrasive compound that greatly increases flu id component wear resulting in equipment failu res and higher maintenance cost. Moisture in a gearbox can cause it to rust from with in. Rust flakes in the lubricant, producing additional abra-sive material, premature wear and failures. Small hydraulic pumps are sensitive to these problems. Hydraulic valves, seals, and other components, require contamination free flu id to function at peak effective-ness and accuracy. These components are increasingly expensive to rebuild or rep lace.

Flow Ezy Air Sentry® stops oil contamination and protects your expensive equipment. Flow Ezy Air Sentry® Min i Contamination Control Breathers are designed for applications when space is limited. They can replace all standard breather caps. They also prevent dirt and water vapor from entering the gearbox or hydraulic system.

BENEFITS • Minimize rust and corrosion • Reduce component wear • Reduce maintenance costs • Prolong fluid life • Reduce oil oxidation

Water vapor is removed as the air travels through a bed of silica gel, the highest capacity absorbent available. After being dried, the air passes through a 2 micron solid particle filter and enters the gearbox or reservoir CLEAN AND DRY! Flow Ezy Air Sentry® is gold when active and dark green when it must be replaced. A threaded mounting hole (1/2” npt) allows easy instal-lation using a wide variety of standard connectors. All models are rated at 10 cfm.

MODEL # A B C D

Z-131 2.00” 1.00” 2.00” 1.75”

Z-132 2.00” 1.00” 3.25” 3.00”

Z-133 3.25” 1.00” 2.00” 1.75”

Z-134 3.25” 1.00” 3.25” 3.00”

B

CD

A

4

The Model A-409 adapter has a 1/2" male NPT thread on one end and a slip fit design on the other end. This adapter is designed to allow a Flow Ezy Air Sentry® Min i Breather to be used with any of the other adapters described above.

Page 8: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“X” SERIES TANK BREATHER WITH TWO CHECK VALVES

In certain extreme operating environments such as a paper mill or a steam cleaning room, the humid ity level far exceeds normal industrial environments. In these situations, lubricants and other fluids stored in tanks and reser-voirs need the protection of a desiccant breather even more. However, s mall temperature variations draw in the humid air and unnecessarily reduce the life of the breather. The Flow Ezy Air Sentry® X-Series breathers incorpo-rate two check valves, one to control airflow into the protected reservoir and one to control airflow out. This p ro-longs the life of the desiccant by allowing the air to flow through the breather only when needed to protect the integrity of the tank. Unlike a membrane system, which does not allow internally generated gases and con-taminants to exit the system, the X-Series offers all of the advantages of breathing air in and out of the tank while removing water vapor and solid particles before they contami-nate the fluid. The rugged design includes a reusable top cap which allows the economic replacement of the desiccant cartridge. The X-Series breathers contain longer lasting desiccant formulated specifically for maxi-mum efficiency at humidity levels of 80% and higher. The mounting methods for the these units are shown below. As in the standard units, the X-Series units require the same mounting methods.

BY-PASS ADAPTER

The Model A-110 Bypass Adapter is designed for applications where there is very heavy oil mist being expelled from the tank. When air is breathed into the tank, it passes through the Flow Ezy Air Sentry® and is cleaned and dried. When the air is breathed out of the tank it enters the adapter and is expelled to the outside without passing back through the breather. This protects the breather from o il contamina-tion.

5

Page 9: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“R” SERIES REMOVABLE CONTAMINATION CONTROL BREATHERS

Flow Ezy Air Sentry® R-Series Breathers are designed for applica-tions where gearboxes and reservoirs are subjected to continuous vi -bration equipment such as railroad maintenance equipment, off-road vehicles, mining equipment, and others. Flow Ezy A ir Sentry® Breathers are gold when active and turn dark green when fully saturated with water. The units are easily attached to the equipment by rugged steel pipe threads. The metal rein forced base of the unit remains on the gearbox or reservoir, and a rep lacement cartridge is easily threaded into the base.

Most gearboxes and hydraulic reservoirs have a sim-ple breather-filler cap that allows air to be breathed in and out as fluid levels change or temperatures in-crease or decrease. Standard breather caps do not stop water vapor and other harmful a irborne contaminants from entering the system. Air Sentry® does! Air in industrial environments contain abrasive solid particles and water vapor. As the system temperature changes, the humid air forms condensation inside the gearbox or reservoir. This moisture decreases fluid and lubricant effectiveness and reduces their service life. Partic le contamination acts as an abrasive compound that increases component wear resulting in equip-ment fa ilures and higher maintenance cost. Moisture in the gearbox can result in acid erosion and rust, two of the worst causes of premature wear and failure . Hydraulic systems are very susceptible to these prob-lems. Valves, seals, and other expensive parts re-

BENEFITS: • Minimize rust and acid corrosion • Reduce component wear • Reduce maintenance cost • Prolong fluid life • Reduce oil oxidation • Enhance lubrication

quire contamination free flu id to function at peak effec-tiveness and to prevent excessive maintenance and re-placement costs. R-Series Breathers are attached to the reservoir, gear-box, or tank by a 1” male pipe thread (Models R-100, R-101, and R-102), and by a 2” male thread (Model R-123). Solid partic les are removed fro m the air entering the gearbox or reservoir as air passes through a 2 micron filter in the Air Sentry®. Water vapor is then removed as the air travels through a bed of silica ge l, the highest capacity absorbent available. Air enters the equipment CLEAN AND DRY!

6

Page 10: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“ M” SERIES HEAVY DUTY INDUSTRIAL STEEL DESICCANT TANK BREATHERS

Flow Ezy Air Sentry® Steel Breathers are manufactured of heavy duty industrial materials and are designed to meet the requirements of the most severe environments. They rep lace the standard breather cap or vent tube on tanks, reservoirs, or gear boxes. Pipe threads on the bottom standpipe make the units easy to install. When the fluid in the system is lowered, or pressure changes occur, air is drawn in through the opening between the protective weather hood and the base. First, the air passes through a fine 2 micron polyester solid particle filter. Next, water vapor is removed as the air travels through a bag of silica gel — the highest capacity ab-sorbent available. Air then enters the system CLEAN AND DRY! Flow Ezy Air Sentry® Steel Breathers are easily rechargeable when the unit has absorbed the maximum amount of water vapor. The bag filter containing silica gel is replaced by removing a wing nut, a washer, and the protective weather hood. Mobile Equipment Applications - Flow Ezy Air Sentry® Steel Breathers include low profile models designed specifically for off-road vehicle use and other applica-tions with limited vertical clearance. Durable Construction - Flow Ezy Air Sentry® Steel Breathers are manufactured of powder coated, durable, heavy gauge steel. They are designed to withstand rough treatment, corrosive environments, and ext reme tempera-ture applications. Polyester Fine Particle Filter - These filters incorporate a very large surface area for maximum dust removal efficiency. They are reinforced with epoxy coated steel wire and may be washed with lukewarm water and mild detergent for reuse. Splash Sentry™ - A proprietary design feature in all Flow Ezy Air Sentry® Steel Breather models prevents fluid in a tank or reservoir from entering the breather when splashed around in a mobile equipment application. It also blocks flu ids which are expelled by excess pressure and foaming in a reservoir.

Relative Humidity Indicator

Bag Filter (Silica Gel)

Fine Particle Filter

360° Air Flow

Clean Dry Air

Splash Entry™

PART NUMBER

DESCRIPTIO N

M-103 10” od, 4” tall, 1” MNPT

M-104 10” od, 4” tall, 2” MNPT

M-105 10” od, 10” tall, 1” MNPT

M-106 10” od, 10” tall, 2” MNPT

M-107 16” od, 11” tall, 3” MNPT

CO

MPL

ET

E U

NIT

S

PART NUMBER

DESCRIPTIO N

A-201 Bag filter w/desiccant for Models M-103 & M-104

A-202 Bag filter w/desiccant for Models M-105 & M-106

A-203 Bag filter w/desiccant for Model M-107

A-204 Pleated filter for Model M-103 & M-104

A-205 Pleated filter for Model M-105 & M-106

A-206 Pleated filter for Model M-107

A-207 Bag filter w/carbon for Model M-203 & M-204

A-208 Bag filter w/carbon for Model M-205 & M-206

A-209 Bag filter s/carbon for Model M-207

RE

PLA

CE

MEN

T PA

RT

S

7

Page 11: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“L” SERIES IN-LINE FILTER / DRYERS

REMOVES WATER VAPOR AND SOLIDS FROM AIR LINES

Flow Ezy Air Sentry® In-Line Filter / Dryers remove water vapor and solid contaminants from air exhaust lines, low pressure compressed air lines, vacuum lines, and other in-line airflow ap-plications where clean dry air is required. Typical applicat ions include hydraulic systems working with pressurized storage tanks or com-pressors, small tool air lines, or venting of pres-surized tanks and reservoirs. Air enters the Filter / Dryer on one end and is cleaned and dried before leaving the other end. Solid particles are removed down to 2 micron. Water vapor is removed as the air passes through a bed of silica gel. The unit is d isposable and changes color from gold to dark green when it is fu lly saturated with water. This color change clearly indicates when the unit needs to be replaced.

Flow Ezy Air Sentry® stops contamination and protects your expensive equipment. Flow Ezy Air Sentry® In-Line Filter / Dryers, are easy to install in the air line between a compressor and a hydraulic tank, or other similar applications. Connections are 1/2” female npt on each end of the Filter / Dryer. MAXIMUM operating pressure is 60 psi. MAXIMUM operating temperature is 200º F.

BENEFITS • Minimize rust and corrosion • Reduce component wear • Reduce maintenance costs • Prolong fluid life • Reduce oil oxidation • Enhance lubricat ion

MODEL HEIGHT DIAMETER AIR FLOW

L-141 5.5” 2.0” 10 cfm

L-142 8.5” 2.0” 10 cfm

L-143 5.5” 3.2” 10 cfm

L-144 5.5” 3.2” 10 cfm

All Flow Ezy Air Sentry® Breathers products are manufactured under an ISO 9001 Certified Qual-ity system in the United States. Other Flow Ezy Air Sentry® Breathers are available for large reservoirs, storage tanks, transformer cases, and other enclosed containers. Units are also available for removing fumes and odors being ex-pelled from tanks, and for neutralizing certain haz-ardous gases expelled from equipment.

8

Page 12: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“GNS” SERIES GAS NEUTRALIZATION BREATHERS

Flow Ezy Air Sentry® GNS (Gas Neutralization System) was designed in coopera-tion with a major international airline / air cargo company for use on ground support equipment. When batteries are charged, gas is produced that contains hydrogen and sulfuric acid. Many health and safety regulations require that charging be performed in a specially designated area where personnel and electrical equipment or open flames are a safe distance away. A lternatively, an expensive investment in gas ex-haust systems is required. The Flow Ezy Air Sentry® GNS Breather provides an economical and simple solu-tion to the problem. The GNS Breathers are easy to install by means of valves at-tached to the battery vents and plastic tubing which conducts the exhaust gases to the GNS mounting point, located either on or off the equipment. This flexib ility allows the charging to take place at the work site or in an enclosed work area where staff is present.

Applications include all mobile and stationary electric battery-powered equipment, forklifts, marine vehicles, and baggage haulers. The GNS utilizes a three-stage filt ration system. As the gas mixture produced during charging moves through the GNS Breather, it first passes through a bed of silica gel that removes the water vapor in which the sulfuric acid gas is suspended. This drying maximizes the life of the second stage and improves its chemical absorption capacity. In the first stage, the hydrogen content of the gas is also slightly reduced. Second, the gas passes through a bed of activated carbon which neutralizes the sulfuric acid gas. Third, the gas exits the GNS Breather through a compos-ite metallic filter/diffuser, which prevents open flames and electrical sparks from entering the GNS unit or the bat-tery system, thus reducing the potential fo r exp losion.

The mounting methods for the GNS units are shown below. As in the standard and activated carbon units, the GNS series requires the same mounting methods.

9

Page 13: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

“D” SERIES ACTIVATED CARBON TANK BREATHERS

Many tanks and reservoirs contain fluids that discharge undesirable gases and odors. Flow Ezy Air Sentry® desiccant breathers are produced which contain Activated Car-bon. This includes the “Disposable Breathers”, “Mini-Breathers”, and our “R-Series Breathers”. Activated Carbon is used extensively in industrial, commercial, and HVA C applicat ions to eliminate many harmful, corrosive, or objectionable gases and odors by chemical absorption. A list of the fluids that produce gases neutralized by Activated Carbon is shown on the back of this Product Information flyer. The Activated Carbon used in Flow Ezy Air Sentry® breathers is made from coconut shell that has been heated to over 2,000° C under h igh pressure. This process causes fissures on the surface of the carbon, creat ing a high quality, s mall pore activated car-bon. It is in these fissures that gases and particles are trapped. There are four models o f Activated Carbon breathers, D-200, D-201, D-202, which use the standard mounting options shown below. The D-208 has a 2” male NPT con-nection. These breathers contain all Activated Carbon. Three Flow Ezy A ir Sentry® breather models, D-301, D-302, D-308, are available which contain both Activated Carbon and Desiccant. These units not only remove the fumes and odors expelled from a tank, they also protect the fluid in the tank from water and solid particle contamination. These are considered disposable units. Units with replaceable carbon bag filters are available with larger units for industrial use. If you have an application which requires a larger capacity of air flow contact Flow Ezy. Flow Ezy Air Sentry® Activated Carbon Breathers are rated at 15 cfm airflow for models with a 1” standpipe, 50 cfm for models with a 2” standpipe, and 100 cfm for models with a 3” standpipe. They use the same mounting adapters that are available for the standard desiccant breathers. The mounting methods for the disposable units are shown below. As in the standard units, the Activated Carbon units require the same ones.

10

Page 14: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

Capacity Index V alue: HIGH Capacity - Carbon absorbs betw een 20% and 40% of its ow n w eight.

GOOD Capacity - Carbon absorbs betw een 10% and 25% of its ow n w eight.

SUBSTANCE INDEX SUBSTANCE INDEX SUBSTANCE INDEXA cetic acid HIGH Ethyl alco hol GOOD Nicroethane HIGHA cetic anhydrite HIGH Ethyl amine GOOD Ni troglycerine HIGHA ceto ne GOOD Ethyl benzene HIGH Ni trom ethane HIGHA crole in GOOD Ethyl bro mide HIGH Ni tro luene HIGHA crylic acid HIGH Ethyl chlo ride GOOD No nane HIGHA crylo nitrile HIGH Ethyl ether GOOD Oc talene HIGHA dhes ives HIGH Ethyl form ate GOOD Odorants HIGHA lcoho lic beverages HIGH Ethyl mercapt an GOOD Organic chemica ls HIGHA myl acetate HIGH Ethyl silic ate HIGH Ozone HIGHA myl ether HIGH Ethylene chlorohydrin HIGH Paint o dors HIGHA nimal odo rs GOOD Ethylene dichloride HIGH Palmit ic acid HIGHA nesthetics GOOD Ethylene oxide GOOD Paper deter io rat ions HIGHA niline HIGH Essentia l o ils HIGH Paradichlorbenzene HIGHA sphalt fum es HIGH Eucalypto le HIGH Paste and g lue HIGHA utom obile exhaust GOOD Exhaust f umes GOOD Pentane HIGHB enzene HIGH Fert ilizer HIGH Pentanone HIGHB leaching s o lutions GOOD Film proc essing orders GOOD Pentylene GOODB romine HIGH Floral sc ents HIGH Perchloroethylene HIGHB utadiene GOOD Fluo rotrichlo romethane GOOD Perfum es and co smetics HIGHB utano ne HIGH Foo d aro mas HIGH Pet odors HIGHB utyhl acet ate HIGH Form ic acid GOOD Pheno l HIGHB utyhl alco hol HIGH Gas oline HIGH Phosgene GOODB utyl c hloride HIGH Heptane HIGH Pi tch HIGHB utyl e ther HIGH Heptylene HIGH Plastic s HIGHB utyric acid HIGH Hexane GOOD Po llen GOODC apryl ic acid HIGH Hexylene GOOD Propio naldehyde HIGHC arbo lic ac id HIGH Hexyne GOOD Propio nic acid HIGHC arbo n tetrochloride HIGH Hos pital odors HIGH Propyl acet ate HIGHC ellos olve HIGH Industrial wast es GOOD Propyl alco hol HIGHC ellos olve acet ate HIGH Ink o dors GOOD Propyl chlo ride HIGHC hees e HIGH Iodine HIGH Propyl ether HIGHC holrine GOOD Isophoro ne HIGH Propyl merc aptan HIGHC hloro benzene HIGH Isoprene GOOD Putres cine HIGHC hloro butadienc e HIGH Isopropyl acet ate HIGH Pyridine HIGHC hloro form HIGH Isopropyl alco hol HIGH Rancid o ils HIGHC hloro nitro papane HIGH Isopropyl ether HIGH Resins HIGHC hloro picrin HIGH Kero sene HIGH Reodo rants HIGHC igarette sm oke odo r HIGH Kitchen o dors HIGH Ripening fru it HIGHC itrus and o ther fruit s HIGH Lact ic ac id HIGH Rubber HIGHC oal s mok e odo r GOOD Liquid fue ls HIGH Sewer odors HIGHC ombustio n odors GOOD Liquor odors HIGH Sm og HIGHC ooking odors HIGH Lubr icating o ils & greas es HIGH Sm oke HIGHC reos ote HIGH Lyso l HIGH So lvents GOODC reso l HIGH M as king agents HIGH St oddard so lvent HIGHC rotonaldehyde HIGH M edicina l odo rs HIGH St yrene mo nom er HIGHC yclohexane HIGH M enthol HIGH Sufuric acid HIGHD ecane HIGH M es ityl o xide HIGH Tar HIGHD ecaying substances HIGH M et hyl ac etat e GOOD Tarnish ing gasses GOODD etergents HIGH M et hyl ac rylat e HIGH Tetrac hloro ethane HIGHD ibrom ethane HIGH M et hyl alcoho l GOOD Tetrac hloro ethylene HIGHD ichlo robenzene HIGH M et hyl bromide GOOD To luene HIGHD ichlo rodif luoro mehtane HIGH M et hyl bu tyl k etone HIGH To luidine HIGHD ichlo ronit roethane HIGH M et hyl fo rmat e GOOD Tr ichlo rethylene HIGHD ichlo ropro pane HIGH M et hyl is obut yl ket one HIGH Turpentine HIGHD ichlo rotet rafluorethane HIGH M et hylcyclohexano ne HIGH Urea HIGHD iesel fumes HIGH M et hylene chloride HIGH Ur ic ac id HIGHD iethylamine GOOD M ildew HIGH Valeric acid HIGHD iethyl keto ne HIGH M onochlorobenzene GOOD Valeric aldehyde HIGHD isinfectants HIGH Naphtha HIGH Varnish fum es HIGHEm balming odo rs HIGH Naphthalene HIGH Vinegar HIGHEpoxy HIGH Nico tene HIGH Xylene HIGHEt her GOOD Nitric acid HIGHEt hyl acetat e GOOD Nitro benzenes HIGH

This table show s the relative capacity of the Activated Carbon (Type AC) used in Flow Ezy A ir Sentry® Breathers to remove selected compounds f rom air under typical ambient conditions.

11

Page 15: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

M OD EL N U M B ER

UN IT HEIGHT

( IN)CLEA R A N

C E ( IN)

TO TAL HE IGHT

( IN)D IA M ETE R ( IN )

U N IT WE IGHT

( LB S )

WA T ER C A PA C IT

Y ( LB S )

B A G N U M B E

R

C A R TRIDG E

NU M B E R

CFM R A TIN

G

GPM PUM P

R ATIN G

CON NEC TION S IZE &

TY P E T Y PE OF M ED IA

D -100 3.50 1.25 4.75 5.00 1.30 0.20 n/a n/a 35 2621" male

friction fit 2 micron filter / s ilica gel

D -101 5.00 1.25 6.25 5.00 1.90 0.40 n/a n/a 35 2621" male

friction fit 2 micron filter / s ilica gel

D -102 8.20 1.25 9.25 5.00 3.30 0.90 n/a n/a 35 2621" male

friction fit 2 micron filter / s ilica gel

D -108 10.00 1.12 11.25 5.00 4.90 1.30 n/a n/a 100 750 2" male npt 2 micron filter / s ilica gel

M-103 4.30 2.30 6.60 10.30 10.00 0.80 A-201 A-204 35 262 1" male npt 2 micron filter / s ilica gel

M-104 4.30 2.30 6.60 10.30 10.00 0.80 A-201 A-204 120 900 2" male npt 2 micron filter / s ilica gel

M-105 9.80 2.30 12.10 10.30 14.00 1.80 A-202 A-205 35 626 1" male npt 2 micron filter / s ilica gel

M-106 9.80 2.30 12.10 10.30 14.00 1.80 A-202 A-205 120 900 2" male npt 2 micron filter / s ilica gel

M-107 10.60 2.90 13.50 16.10 41.50 8.80 A-203 A-206 300 2250 3" male npt 2 micron filter / s ilica gel

Z -131 1.75 0.25 2.00 2.00 0.19 0.03 n/a n/a 10 751/2" female

npt 2 micron filter / s ilica gel

Z -132 3.00 0.25 3.25 2.00 0.27 0.06 n/a n/a 10 751/2" female

npt 2 micron filter / s ilica gel

Z -133 1.75 0.25 2.00 3.25 0.50 0.11 n/a n/a 10 751/2" female

npt 2 micron filter / s ilica gel

Z -134 3.00 0.25 3.25 3.25 0.75 0.18 n/a n/a 10 751/2" female

npt 2 micron filter / s ilica gel

R -100 4.00 1.00 5.00 5.20 6.00 0.20 n/a A-300 35 262 1" male npt 2 micron filter / s ilica gel

R -101 5.50 1.00 6.50 5.20 7.40 0.40 n/a A-301 35 262 1" male npt 2 micron filter / s ilica gel

R -102 8.50 1.00 9.50 5.20 10.00 0.90 n/a A-302 35 262 1" male npt 2 micron filter / s ilica gel

R -123 10.50 1.50 12.00 5.20 12.20 1.30 n/a A-323 100 750 2" male npt 2 micron filter / s ilica gel

R -111 5.50 1.00 6.50 5.20 7.40 0.40 n/a A-301 35 26211/8-16 fml check valve 2 micron filter / s ilica gel

C -101 5.00 1.25 6.25 5.00 1.90 0.40 n/a n/a 35 2621" male

friction fit 25 micron filter / s ilica gel

C -102 8.20 1.25 9.25 5.00 4.90 0.90 n/a n/a 35 2621" male

friction fit 25 micron filter / s ilica gel

C -108 10.00 1.25 11.25 5.00 4.90 1.30 n/a n/a 100 7502" male

friction fit 25 micron filter / s ilica gel

M OD EL N U M B ER

UN IT HEIGHT

( IN)CLEA R A N

C E ( IN)

TO TAL HE IGHT

( IN)D IA M ETE R ( IN )

U N IT WE IGHT

( LB S )

WA T ER C A PA C IT

Y ( LB S )

R EPL. B A G

N U M B ER

R E PL. C A R TRID

G E NU M B E R

CFM R A TIN

G

GPM PUM P

R ATIN G

CON NEC TION S IZE &

TY P E T Y PE OF M ED IA

D -301 5.00 1.25 6.25 5.00 1.80 0.30 n/a n/a 15 1121" male

friction fit2 micron filter, slica gel and

activated carbon (btm)

D -302 8.00 1.25 9.25 5.00 3.10 0.70 n/a n/a 15 1121" male

friction fit2 micron filter, slica gel and

activated carbon (btm)

F-302 8.00 1.25 9.25 5.00 3.00 0.70 n/a n/a 15 112

1" male friction fit

2 micron filter, slica gel, and activated carbon (top)

spark & flame ar res tor

F-309 16.00 1.25 17.25 5.00 5.10 1.40 n/a n/a 15 112

1" male friction fit

2 micron filter, slica gel, and activated carbon (top)

spark & flame ar res tor

SOLID PARTICLE AND WATER REMOVING BREATHERS

FUME / ODOR, WATER, AND SOLID PARTICLE REMOVING BREATHERS

12

Page 16: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

M OD EL

N U M B ER

U N IT HEIGHT

( IN )C LEA R A N

C E ( IN )

T OTA L HE IGHT

( IN )D IA M ETER ( IN )

U N IT W EIG HT

( LB S )

WA TER C A P A C ITY ( LB S )

B A G N U M B E

R

C A R TR IDGE

N U M B ER

C F M R A TIN

G

G P M P U M P

R A TIN G

C ON N EC T ION S IZE &

TY P E TY P E OF M ED IA

L -14 1 5.00 0.50 5.50 2.00 3.00 0.70 90 n/a 10 751/2" f ml npt both ends

2 micron filter and silica gel

L -14 2 8.00 0.50 8.50 2.00 3.80 0.13 90 n/a 10 751/2" f ml npt both ends

2 micron filter and silica gel

L -14 3 5.00 0.50 5.50 3.20 5.30 0.25 90 n/a 10 751/2" f ml npt both ends

2 micron filter and silica gel

L -14 4 8.00 0.50 8.50 3.20 7.70 0.44 90 n/a 10 751/2" f ml npt both ends

2 micron filter and silica gel

L -24 1* 5.00 0.50 5.50 2.00 2.40 n/a 22 n/a 3 221/2" f ml npt both ends

2 micron filter and ac tivated carbon

L -24 2* 8.00 0.50 8.50 2.00 2.80 n/a 22 n/a 3 221/2" f ml npt both ends

2 micron filter and ac tivated carbon

L -24 3* 5.00 0.50 5.50 3.20 3.10 n/a 22 n/a 3 221/2" f ml npt both ends

2 micron filter and ac tivated carbon

L -24 4* 8.00 0.50 8.50 3.20 4.50 n/a 22 n/a 3 221/2" f ml npt both ends

2 micron filter and ac tivated carbon

* The L-241, L-242, l-243, and L-244 units are not to be used to remove w ater.

M OD EL N U M B ER

U N IT HEIGHT

( IN )C LEA R A N

C E ( IN )

T OTA L HE IGHT

( IN )D IA M ETER ( IN )

U N IT W EIG HT

( LB S )

WA TER C A P A C ITY ( LB S )

B A G N U M B E

R

C A R TR IDGE

N U M B ER

C F M R A TIN

G

G P M P U M P

R A TIN G

C ON N EC T ION S IZE &

TY P E TY P E OF M ED IA

D -2 00 3.50 1.25 4.75 5.00 1.10 n/a n/a n/a 15 1121" male

f riction f itactivated carbon /

2 mic ron filter

D -2 01 5.00 1.25 6.25 5.00 1.60 n/a n/a n/a 15 1121" male

f riction f itactivated carbon /

2 mic ron filter

D -2 02 8.00 1.25 9.25 5.00 2.80 n/a n/a n/a 15 1121" male

f riction f itactivated carbon /

2 mic ron filter

D -2 08 1.00 1.25 11.25 5.00 4.90 n/a n/a n/a 50 375 2" male nptactivated carbon /

2 mic ron filter

M -2 03 4.30 2.30 6.60 10.30 8.90 n/a A-207 A -204 15 112 1" male nptactivated carbon /

2 mic ron filter

M -2 04 4.30 2.30 6.60 10.30 9.10 n/a A-207 A -204 50 375 2" male nptactivated carbon /

2 mic ron filter

M -2 05 9.80 2.30 12.10 10.30 11.50 n/a A-208 A -205 15 112 1" male nptactivated carbon /

2 mic ron filter

M -2 06 9.80 2.30 12.10 10.30 11.70 n/a A-208 A -205 50 375 2" male nptactivated carbon /

2 mic ron filter

M -2 07 10.60 2.90 13.50 16.10 30.50 n/a A-209 A -206 100 750 3" male nptactivated carbon /

2 mic ron filter

Z -23 1 1.75 0.25 2.00 2.00 0.19 0.03 n/a n/a 3 22.51/2" f emale

nptactivated carbon /

2 mic ron filter

Z -23 2 3.00 0.25 3.25 2.00 0.27 0.06 n/a n/a 3 22.51/2" f emale

nptactivated carbon /

2 mic ron filter

Z -23 3 1.75 0.25 2.00 3.25 0.50 0.11 n/a n/a 3 22.51/2" f emale

nptactivated carbon /

2 mic ron filter

Z -23 4 3.00 0.25 3.25 3.25 0.75 0.18 n/a n/a 3 22.51/2" f emale

nptactivated carbon /

2 mic ron filter

R -2 00 4.00 1.00 5.00 5.20 6.00 0.20 n/a A -313 15 11.2 1" male nptactivated carbon /

2 mic ron filter

R -2 01 5.50 1.00 6.50 5.20 7.40 0.40 n/a A -314 15 11.2 1" male nptactivated carbon /

2 mic ron filter

R -2 02 8.50 1.00 9.50 5.20 10.00 0.90 n/a A -315 15 11.2 1" male nptactivated carbon /

2 mic ron filter

R -2 23 10.50 1.50 12.00 5.20 12.20 1.30 n/a A -324 50 375 2" male nptactivated carbon /

2 mic ron filter

INLINE FILTERS AND DRYERS

FUME / ODOR AND SOLID PARTICLE REMOVING BREATHERS (Not to be used for removing water)

13

Page 17: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

A BRIEF LIST OF INDUSTRIES AND MARKETS THAT USE DESICCANT TANK BREATHERS

INDUSTRY / MARKET REMARKS

Aluminum ext rusion forging and rolling mills These operations are almost exclusively oriented to hy-draulic equipment.

Appliance manufacturers Stampings – look for large hydraulic presses and some gear boxes

Automotive industry This industry is intensively equipped with hydraulic ma-chinery, gearboxes, and robots.

Large transformer & switch gear manufacturers They use a large amount of insulating oil (transformer oil), which can get contaminated. They often do rebuild-ing work and need to reclaim o il.

Aerospace and high tech welding applications Most are performed in a vacuum, or other controlled atmosphere. Reduce pump-down times and increase productivity with Flow Ezy A ir Sentry®.

Day tanks on diesel powered generators In almost every large building, moisture contamination is a big problem because desiccant tank breathers are seldom used.

Paper and pulp mills There are many applications in these plants for Flow Ezy Air Sentry® breathers. Gearboxes, gear reducers, & hydraulics. Powerhouse turbine lube oil, the lube oil systems for dryers. The main lube system for the calen-dar stack drive bearings.

Oil drilling industry Hydraulics on the mobile equipment, gearboxes. In ar-eas of the south, and long the coast, there are very humid conditions. Mobile equipment in the field is subject to huge amounts of dust contamination.

E.D.M. die making Electro-discharging machining is a high metal removing process producing a lot of contaminated oil.

Food processing plants Wash down of equipment makes moisture a real problem in hydraulic reservoirs and gearboxes.

Large machine shops Big users of petroleum cutting oil.

Food products: oils, grains, syrups Particularly important during filling and emptying opera-tions.

Off road vehicles Filtering moisture and dirt, from air going to differen-tials, transmissions, loader cylinders, etc.

Automatic screw machines These are basically high production lathes, which often use petroleum based cutting oils.

Chemical & Petro-chemical p lants Micronic filtrat ion of the process stream. Lube oil de-gassing and conditioning. Turbine and seal oil.

Acid and chemical storage Moisture and dirt alters the fluid

Jet fuel storage at large airports Water or dirt contamination results in loss of entire prod-uct.

Plastic injection molding Big user of hydraulic petroleum based equipment.

Power p lants & utilities Filtration application is on the main steam turbines, boil-ers, feed pumps, and any peaking units. Transformer o il treatment is another obvious application.

Steam & gas turbine manufacturers Paper mills, petrochemical plants, refineries, and even distilleries are turbine users. Off shore oil drilling plat-forms utilize gas turbines for their main electrical gener-ating power source.

14

Page 18: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

A BRIEF LIST OF INDUSTRIES AND MARKETS THAT USE

DESICCANT TANK BREATHERS

Steel ro lling mill & forge plants A typical steel rolling mill has two stories of hydraulic equipment beneath the roll stands. They periodically contaminate this hydraulic oil with water based rolling flu ids. Flow Ezy A ir Sentry® could prevent the con-tamination of moisture that gets in through the breather cap.

Wire manufacturers Water base, oil base, and dry lubricants are used in wire production.

Mining companies They operate expensive hydraulically powered equip-ment, which are exposed to a very nasty environment.

15

FREQUENTLY ASKED QUESTIONS

CAN I REPLACE OR REGENERATE THE SILICA GEL AFTER IT CHANGES COLOR? With the exception of the Steel Breathers, you cannot replace the silica gel. The Steel Breathers have a replace-able bag of silica gel. All other Flow Ezy A ir Sentry® Breathers are designed so you cannot remove the cap. This is to assure that solid particles, water vapor, or silica gel beads do not accidentally enter the tank or reser-voir. The silica gel can be regenerated by blowing hot air through the breather (about 300° F for three or four hours). We do not believe this is economical. WHAT SIZE BREATHER DO I USE? The size of the tank or reservoir does not determine the model of breather to use. The air flow, both IN and OUT of the tank or reservoir determines the model to choose. Two factors create air flow. They are fluid vol-ume changes and temperature variations. The air flow rating for each Flow Ezy A ir Sentry® model is stated in the sales literature. CAN A BREATHER BE MOUNTED IN ANY POSITION, VERTICAL, HORIZONTAL, OR AT AN AN-GLE? Breathers should be mounted in the vertical position, or at least no more than a 45° angle. Even though Flow Ezy Air Sentry® Breathers are vibrated during assembly to assure maximum filling, the silica gel settles during shipment, creating an air passage above it when the unit is in the horizontal position. Air, like people, takes the path of least resistance, and with the breather in the horizontal position, the air would bypass the silica gel and enter the tank undried. HOW MUCH WATER DOES MY BREATHER HOLD? The amount of water that a Flow Ezy Air Sentry® Breather holds is up to 40% of the weight of the silica gel in that model b reather. We say “up to” because the percentage is dependent upon the relative humidity the breather is operating in. Ideal conditions (40%) occur at approximately 70° F. And 75-80% humidity. If a customer is concerned that a breather’s life is too short, they need to understand that when it has turned completely dark green it holds the same quantity of water, regardless of how long it took for it to change color. In the D-102 that is about 2 cups of water. The D-102 is the most economical model for a customer to purchase. MUST THE BREATHER ALWAYS BE MOUNTED ON THE TANK OR CAN IT BE REMOTELY MOUNTED? It is often desirable to mount the breather away from the tank for better visibility or easier access for changing the units. You can mount the unit remotely by using tubing or pipes for the air to flow from the breather to the tank. Be sure there are no obstructions in the line and no air leaks. Rig id pip ing, with a 90° elbow, can also be used to achieve a vert ical breather position for applications where the opening in the tank is on the side or where there is not enough space above the tank for a b reather.

Page 19: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

FREQUENTLY ASKED QUESTIONS (continued from previous page)

HOW DO I DISPOSE OF A USED FLOW EZY AIR SENTRY®? Always check local regulations. Having said that, be assured that Flow Ezy Air Sentry® Breathers are manufac-tured with all materials that can be disposed of as solid waste, as defined by local regulat ions. However, if a breather is used on a tank that contains a regulated fluid, the breather must be disposed of in the same manner as required for the flu id. HOW DO I KNOW WHEN THE BREATHER HAS ABSORBED ALL THE WATER IT CAN HOLD? As the Flow Ezy Air Sentry® adsorbs water the silica gel turns from go ld to very dark b lue/green. In fact, it looks black to many people. Seeing a light green color throughout the gold is not a signal to replace the breather. When all of the silica gel has changed color, to very dark b lue/green, the breather should be replaced. A breather that still has a small amount of gold or light green color showing is just as good as when it had not started to change color. I DON’T SEE ANY WATER IN MY TANK. DO I REALLY NEED TO PAY FOR A DESSICANT BREATHER? IT'S THERE, EVEN IF YOU DON'T SEE IT - AND IT'S COSTING YOU MONEY. There are three states of water contamination in lubricants, hydraulic flu id, insulating oil, etc. DISOLVED WATER - these molecules are dispersed one-by-one throughout the oil like Humidity; EMULSIFIED WATER - these microscopic globules of water are suspended in the oil like fog; FREE WATER - settles to the bottom of the tank like rain. All forms of water are generators of other contamination: rust, sludge, acids, soot, bacteria, varnish, and ice. All of these shorten the life of the oil or fluid and the equipment serviced by it. HOW LONG DOES A BREATHER LAST? There is no set time frame that a Flow Ezy Air Sentry® breather will last. The size of the breather, as well as the environment it is in, will determine the life span of a breather. Generally speaking, a small Mini breather will not have the same life expectancy as a larger Disposable Breather. The useful life of a breather has three variables. They are: · Frequency of Breathing means how often does a new batch of wet air pass through the breather. Each time th is happens, water vapor is retained and the breather life is shortened. Examples of the ext remes would be a storage tank that has fluid drawn out once a day and a hydraulic cylinder stroking every 30 seconds. · Quantity of Silica Gel: The water holding capacity of a breather is directly proportional to the amount of silica gel in the breather. Silica gel has the capability to remove up to 40% of its own weight in water. · Ambient Humidity in the Work Area: Most users believe that the ambient humid ity is the major factor in the life of the breather. However, humidity works for us, as well as against us. As each load of wet air passes through the breather, the air with more humid ity brings more water vapor to adsorb, but the silica gel can adsorb more at the higher humidity level. The end result is a small decrease in the life of the breather at higher work area humidity levels, but this is not as significant as the other two life factors. Most breathers in industrial applications will last 3 to 6 months, if sized properly. The first breather put on a tank or reservoir that has been in operation for a period of time will usually have a shorter life than subsequent breathers because it is having to dry air leav ing the reservoir as well as coming in. Our customers have used Flow Ezy Air Sentry® breathers in nearly every climate possible. Some breathers will last 2 months on a fluid storage tank, some will last over a year. When the silica gel changes from gold to green, it is time to rep lace the breather. CAN I USE MY FLOW EZY AIR SENTRY® BREATHER OUTDOORS IN COLD OR HOT CONDITIONS? Yes, Flow Ezy Air Sentry® Breathers are designed for use in temperatures ranging from –20° F to 200° F. CAN I USE MY FLOW EZY AIR SENTRY® BREATHER ON MOBILE EQUIPMENT? IT’S A PRETTY ROUGH ENVIRONMENT! FLOW EZY AIR SENTRY® BREATHERS ARE DESIGNED FOR RUGGED ENVIRONMENTS. Two groups of Flow Ezy Air Sentry® products are designed for these applications. The "R-Series" breathers was designed in cooperation with a major U.S. railroad for applications with severe vibration. There is a metal reinforcing plate in the bottom cap and the connection to the reservoir is made with a steel p ipe nipple. The Steel Breathers are de-signed for applications where the un its may be used as a step to enter a cab or hit by flying objects or other equip-ment. They are designed with a 16 gage steel body.

16

Page 20: Air Sentry - Energy Statement App 3 Dessicant and Filters.pdf

PHOTOS OF FLOW EZY AIR SENTRY® BREATHERS USED IN ACTUAL APPLICATIONS

17