  • Air-cooled Packaged Air-conditioners

    CED 5kW_25kW_P SeriesDisplacement_Conventional_Underfloor_High-Front

    Made to get the ideal CLIMATE for any season

    DPC ROOM

    www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it

  • * * On specific request

    Indoor air-cooled packaged air-conditioners to be coupled to remote condensing, ideal for installation in rooms, equipment rooms, DPC and technological rooms in general.

    The pre-galvanised steel structure painted with epoxy powder paint is supported by a thick internal structure. The panels are supplied with sound-absorbent and isolating material.

    The structure is realised with single or double doors, depending on cooling capacity requested.

    The air conditioners for DPC Rooms can be equipped:

    - without free-cooling system (RR vers.) - with free-cooling system (RF vers.)

    The process air can be carried in different ways:

    Ÿ from the low horizontal to displacement (DISPLACEMENT) Air return at the top (roof), flow down the front, low speed

    Ÿ from the low horizontal (CONVENTIONAL)High air return (at the roof), front delivery

    Ÿ

    Ÿ towards the low vertical (UNDERFLOOR) High air return (at the roof), delivery low underfloor

    Ÿ upwards (HIGH-FRONT)**Air return from low front, delivery upwards (roof)

    In the standard version with free-cooling, the air conditioner will only accept the channeling from above (with the exception of the HIGH FRONT where the outside air is taken in the preparation back).

    For fixing the channel in the rear make a specific request at time of order so as to be able to perform the operations of adjustment at the factory.

    The air-conditioners are supplied with internal controller and temperature and pressure probes, which allow to realise an autonomous and co-ordinated "air-conditioning system" thus ensuring complete redundancy on all of the control and air-conditioning functions.

    The air-conditioners are supplied with the User Interface Panel on the machine, for command and control management.

    The DPC Range air-conditioners are supplied with process air filter and condensate collection tray; they are characterised by maximum accessibility and strength.

    DPC ROOM

    www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it

    CED*RR**SPCED*RF**SP

    CED*RR**FPCED*RF**FP

    (*) Indicate the machine power

    (**) Indicate SINGLE-PHASE (1) or THREE-PHASE (3) power supply voltage

    CODE NAMING

    CED*RR**DPCED*RF**DP

    CED*RR**CPCED*RF**CP

    Displacement Conventional

    Underfloor High_Front

    Ÿ Support structure and external panels in galvanised steel

    Ÿ High resistance to corrosion

    Ÿ Hermetic Scroll Compressor type

    Ÿ Electronic expansion valve

    Ÿ Evaporating fans type A tionalC (EC op )

    Ÿ Condensing fans type AC ptional (EC o )

    Ÿ Condensing section variable fan speed depending on the condensation pressure

    Ÿ Air handling section 48 Vcc

    Ÿ U U class air filter Dirty filter differential pressure switchE 3/G3 - E 4/G4 -

    Ÿ User interface panel on the unit equipped with magnetic switches and displays with keyboard

    Ÿ PLC for management and control operation with configurable parameters

    Ÿ Interface serial RS232 / RS485 or Ethernet

    Ÿ Configurable analog and digital inputs / outputs

    Ÿ Alarm outputs on two or more levels

    Ÿ Automatic re-start after a power shut-down

    TECHNICAL FEATURES

  • Compressor

    Total Cooling Capacity (1)

    Sensitive Cooling Capacity (1)

    Heating capacity (optional)

    Power supply voltage

    Maximum absorbed power

    Maximum absorbed current

    Evaporating section air flow rate

    Auxiliary power supply voltage

    Width

    Depth

    Height

    Weight

    Refrigerant

    Noise

    Operating temperature limit

    (1) The cooling capacity refers to the following conditions: Outdoor temperature 35°C - Indoor temperature 27°C - R.H.=50%

    Scroll Scroll Scroll Scroll

    5600 / 8200 8800 / 12600 15000 / 19200 21000 / 27000

    5200 / 7600 8200 / 12200 14300 / 18400 19800 / 25600

    2000 2000 3000 4000

    230/1/50 230/1/50

    2500 / 3700 4200 / 5500 6500 / 8500 9200 / 11500

    11 / 176 / 8

    9.5 / 12 14 / 17

    1700 2200 4500 4500

    48 48 48 48

    600 (1 door) 800 (1 door) 1200 (2 doors) 1600 (2 doors)

    800 800 800 800

    1900 1900 1900 1900

    190 250 335 400

    R407C

    44 44 44 44

    -20° +45° -20° +45° -20° +45° -20° +45°

    W

    W

    W

    V/pH/Hz

    W

    A

    m³/h

    Vdc

    mm

    mm

    mm

    Kg

    Db(A)

    C

    40/70 Model

    R407C R407C R407C

    80/120 140/180 200/250

    400/3/50400/3/50 400/3/50

    19 / 24

    DPC ROOM

    www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it

    * High-Front version

    ExternalAir inlet

    *The rear upper openings are present only if the machine is provided free-cooling* Displacement - Conventional - Underfloor versions

    InternalAir inlet

    InternalAir inlet

    Front view Side view

    Rear views

    *The rear openings for the free-cooling are present only on specific request*In the High-Front version with free-cooling punctures are located in the lower back

    DATI TECNICI

    Wiew from above

  • DPC ROOM

    www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it

    DISPLACEMENT

    Calda

    Fredda

    Fredda Fredda

    Calda

    Fredda

    Fredda

    Fredda Fredda

    Fredda(OPTIONAL SU RICHIESTA)

    CONVENZIONTIONAL

    STANDARD

    OPTIONAL

    Canaledi ripresa

    Calda

    Fredda

    Calda

    Fredda

    Fredda

    Fredda(OPTIONAL SU RICHIESTA)

    STANDARD

    OPTIONAL

    Canaledi ripresa

    Air return at the top (roof), flow down the front, low speed

    High air return (at the roof), front delivery

    COOLINGmode

    FREE-COOLINGmode

    COOLINGmode

    FREE-COOLINGmode

    Hot

    ColdCold(OPTIONAL on request)

    Hot

    Cold

    Hot

    ColdCold(OPTIONAL on request)

    Cold

    Cold Cold

    Cold

    Cold Cold

    Hot

    Canalization

    Canalization

  • Sale ced

    www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it

    UNDERFLOOR

    HIGH_FRONT

    FreddaFredda

    Calda

    Calda

    Fredda

    Fredda

    Fredda(OPTIONAL SU RICHIESTA)

    STANDARD

    OPTIONAL

    Canaledi ripresa

    IN FREE-COOLING

    MODALITA' VERSO L'ALTO-FRONT

    Fredda

    Calda

    MODALITA' VERSO L'ALTO-FRONT

    Fredda

    Calda

    Fredda

    High air return (at the roof), delivery low underfloor

    Air return from low front, delivery upwards (roof)

    COOLINGmode

    FREE-COOLINGmode

    COOLINGmode

    FREE-COOLINGmode

    Canalization

    Cold Cold

    Hot

    Hot

    ColdCold(OPTIONAL on request)

    Cold

    Cold

    Hot

    Cold

    Hot

    Cold

  • Pro

    dotto c

    ost

    ruito

    e a

    ssem

    bla

    to in

    Ita

    lia -

    Pro

    duct

    s m

    anufa

    cture

    d a

    nd a

    ssem

    ble

    d Ita

    ly

    www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it www.ethratech.it

    Ethra Tech srl Via dell’Artigianato,12 - 06056 Massa Martana (Pg) - ItalyTel. +39 075.889071 - Fax +39 075.88907215e-mail: [email protected] - web: www.ethratech.it

    DPC ROOM

    CANALIZATION

    Vertical Airflow Horizontal AirflowVertical Horizontal

    CANALIZATION REAR ZONEOPTIONAL ON REQUEST

    Vertical Airflow Horizontal AirflowVertical Horizontal

    CAPACITORS

    Possibility of canalization for models of free-cooling system.

    CED40xxxxx

    CED70xxxxx

    CED80xxxxx

    CED120xxxxx

    CED140xxxxx

    CED180xxxxx

    CED200xxxxx

    CED250xxxxx

    AE80-OS

    CONDENSING

    INDOOR UNIT

    AE80-VS

    AE80-OS AE80-VS

    AE80-OS AE80-VS

    AE100-OS AE100-VS

    AE140-OS AE140-VS

    AE180-OS AE180-VS

    AE250-OS AE250-VS

    AE250-OS AE250-VS

    INDOOR UNIT - CONDENSING UNIT association table

    Pagina 1Pagina 2Pagina 3Pagina 4Pagina 5Pagina 6