38
“C/CW/CC” Series Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position Catalog 0640-E/USA April 2004

Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

“C/CW/CC” SeriesAir Control Valves

3-Way, 3-Port, 2-Position4-Way, 4-Port, 2-Position

Catalog 0640-E/USAApril 2004

Page 2: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

WARNINGFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBEDHEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provideproduct and/or system options for further investigation by users having technical expertise. It is important that you analyzeall aspects of your application including consequences of any failure, and review the information concerning the product orsystem in the current product catalog. Due to the variety of operating conditions and applications for these products orsystems, the user, through its own analysis and testing, is solely responsible for making the final selection of the productsand systems and assuring that all performance, safety and warning requirements of the application are met.The products described herein, including without limitation, product features, specifications, designs, availability and pricing,are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

Offer of SaleThe items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or itsauthorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of thisdocument entitled “Offer of Sale”.

© Copyright 2004, Parker Hannifin Corporation. All Rights Reserved

!

Page 3: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

C/CW Basic Valve Features .......................................................................................................2C/CW Model Number Index .......................................................................................................3Single Solenoid & Remote Pressure

CJ1, CWJ1, C10, CW10 .......................................................................................................4Double Remote Pressure & Cam Operated

C12, CW12, C2, CW2 ...........................................................................................................5Cam Operated

C94, CW94, C92, CW92, C13, CW13, C9, CW9 .............................................................. 6-7Hand Operated

C5, CW5, C4, CW4 ............................................................................................................... 8Hand & Foot Operated

C3, CW3, C6 .........................................................................................................................9Pedal Guard / C/CW Technical Data .................................................................................. 10

Dimensions3-Way, 2-Position Single Solenoid ...................................................................................... 113-Way, 2-Position Remote Pressure ................................................................................... 123-Way, 2-Position Heavy Duty Cam Operated .................................................................... 133-Way, 2-Position Cam Operated ....................................................................................... 143-Way, 2-Position Hand Operated ...................................................................................... 153-Way, 2-Position Foot Operated & Guard ......................................................................... 16

CC Basic Valve Features ......................................................................................................... 18CC Model Number Index .......................................................................................................... 19Single & Double Solenoid

CCJ1, CCJ11 ...................................................................................................................... 20Remote Pressure

CC10, CC12........................................................................................................................ 21Cam Operated

CC92, CC94, CC9, CC13, CC2 .....................................................................................22-24Hand Operated

CC3, CC4, CC5 .............................................................................................................24-25Foot Operated

CC6..................................................................................................................................... 26Pedal Guard ........................................................................................................................ 26

CC Technical Data ................................................................................................................... 27Dimensions

4-Way, 4-Port, 2-Position Single Solenoid .......................................................................... 274-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure ........................................ 284-Way, 4-Port, 2-Position Cam Operated ........................................................................... 294-Way, 4-Port, 2-Position Cam & Hand Operated .............................................................. 304-Way, 4-Port, 2-Position Foot Operated & Guard ............................................................. 31

OptionsFlow Control Section ........................................................................................................... 32

C/CW/CC Cross Reference.................................................................................................33-34Offer of Sale ............................................................................................................................. 35

1

“C/CW/CC” Series ValvesTable of Contents

Catalog 0640-E/USA

Table of Contents

Page 4: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

CJ1 Series

Features

• 3-Way, 2-Position.

• Single Solenoid.

• Single Air Pilot.

• Manual, cam, hand, and foot operators.

• Inline mounting.

• Wall or base mounting.

• Ports: 1/4 and 3/8 inch.

• No minimum operating pressure.

• Cv 2.0.

• Suitable for vacuum service.

• May be used as diverter.

• Solenoid valve is CSA approved.

• Body - sandcast aluminum.

2

“C/CW” Series ValvesAir Control Valves

Catalog 0640-E/USA

Basic Valve Features

Page 5: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic3

“C/CW” Series ValvesAir Control Valves

Catalog 0640-E/USA

Model Number Index

Basic Valve Port Coil Series Operator Size Option Modification

C J1 25 01 --

Valve Operators

Manual/Mechanical 2 Ball Cam, Spring Return 3 Palm Button, Spring Return 4 Hand Toggle, Non-Locking 5 Hand Toggle, Locking 6 Non-Locking Foot Actuator * 10 Remote Pressure, Spring Return 12 Double Remote Pressure 13 Roller Cam, Spring Return 92 Heavy Duty, Uni-Directional Roller Lever,

Spring Return 94 Heavy Duty, Bi-Directional Roller Lever,

Spring Return

Alternating Current Solenoids J1 Single Solenoid, Spring Return,

Non-Locking Override* Available in 1/4" only.

Basic Series

C 2-Position, 3-Way, 3-Port, NC/NO Inline Valve, Horizontal Mounting

CW 2-Position, 3-Way, 3-Port, NC/NO Inline Valve, Vertical Mounting (Wall Mount)

Port Size

25 1/4" 37 3/8" *

* Not available with operator 6

Modification

Blank None M28 Viton Seals

Coil Option - A.C. Solenoid

01 120V/60Hz

Note: Refer to back of Catalog for Cross Reference Information.

(Revised 04-06-11)

Page 6: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

CJ1 CWJ1 C10 CW10

ApplicationThese 3-Way, 2-Position, remote pressure operated spoolvalves are used to operate single acting cylinders. Theycan be used as normally closed or normally open, and asa 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B”. When pilot is energized, port “A” is connected to port“0” and port “B” is blocked. Because of the area-balancedconstruction of the spool, either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” is normally open valve.

ApplicationThese 3-Way, 2-Position, direct solenoid operated, (maintainedcontact) spool valves are used to operate single actingcylinders. They can be used as normally closed or normallyopen, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationSolenoid De-energized – Port “A” is blocked, port “0” isconnected to port “B”. When solenoid is energized, port “A” isconnected to port “0” and port “B” is blocked. Because of thearea-balanced construction of the spool, either port “A” or port“B” may be used as the inlet supply port. Pressure to port “A”valve is normally closed valve. Pressure to port “B” valve isnormally open valve.

Model Selection Information

Port Size Description Model Number

1/4" NPT Base Mounted C10253/8" NPT Base Mounted C1037

Port Size Description Model Number

1/4" NPT Wall Mounted CW10253/8" NPT Wall Mounted CW1037

Model Selection InformationFollowing model numbers are for 120V/60Hz.

Port Size Description Model Number

1/4" NPT Base Mounted CJ125013/8" NPT Base Mounted CJ13701

Port Size Description Model Number

1/4" NPT Wall Mounted CWJ125013/8" NPT Wall Mounted CWJ13701

0

B

0

A

Normally OpenNormally Closed

A B

0

B

0

A

Normally OpenNormally Closed

A B

4

“C/CW” Series Valves3-Way, 2-Position

Catalog 0640-E/USA

Single Solenoid & Remote Pressure

Page 7: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

C12 CW12 C2 CW2

ApplicationThese 3-Way, 2-Position, cam operated spool valves are used tooperate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting to horizontalsurfaces. Use “CW” Series for mounting to vertical bulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B”. When ball is activated, port “A” is connected to port “0”and port “B” is blocked. Because of the area-balancedconstruction of the spool, either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” is normally open valve.

ApplicationThese 3-Way, 2-Position, double remote pressure operatedspool valves are used to operate single acting cylinders. Theycan be used as normally closed or normally open,and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationWhen pressure is applied to port “2” last, pressure at inlet port“A” is blocked and port “0” is connected to port “B”. Whenpressure is applied to port “1” last, port “A” is connected to port“0” and port “B” is blocked. Because of the area-balancedconstruction of the spool, either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” valve is normally open valve.

Model Selection Information

Port Size Description Model Number

1/4" NPT Base Mounted, Ball Cam C2253/8" NPT Base Mounted, Ball Cam C237

Port Size Description Model Number

1/4" NPT Wall Mounted, Ball Cam CW2253/8" NPT Wall Mounted, Ball Cam CW237

Model Selection Information

Port Size Description Model Number

1/4" NPT Base Mounted C12253/8" NPT Base Mounted C1237

Port Size Description Model Number

1/4" NPT Wall Mounted CW12253/8" NPT Wall Mounted CW1237

0

B

0

A

Normally OpenNormally Closed

A B

0

B

0

A

Normally OpenNormally Closed

#2OperatorEnd

#1Operator

End

#1Operator

End

#2OperatorEnd

A B

5

“C/CW” Series Valves3-Way, 2-Position

Catalog 0640-E/USA

Double Remote Pressure & Cam Operated

Page 8: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

C94 & CW94 Heavy Duty C92 & CW92 Overriding Cam

ApplicationThese 3-Way, 2-Position, cam operated spool valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B”. When cam is activated, port “A” is connected to port “0”and port “B” is blocked. Because of the area-balancedconstruction of the spool, either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” is normally open valve.

C92 and CW92 are overriding cams which operate in onedirection only.

ApplicationThese 3-Way, 2-Position, cam operated spool valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B”. When cam is activated, port “A” is connected to port “0”and port “B” is blocked. Because of the area-balancedconstruction of the spool, either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” valve is normally open valve.

C94 and CW94 operate from either direction.

Model Selection InformationPort Size Description Model Number

1/4" NPT Base Mounted, Heavy Duty, C9225Overriding Roller Lever

3/8" NPT Base Mounted, Heavy Duty, C9237Overriding Roller Lever

Port Size Description Model Number

1/4" NPT Wall Mounted, Heavy Duty, CW9225Overriding Roller Lever

3/8" NPT Wall Mounted, Heavy Duty, CW9237Overriding Roller Lever

Model Selection InformationPort Size Description Model Number

1/4" NPT Base Mounted, Heavy Duty, C9425Roller Lever

3/8" NPT Base Mounted, Heavy Duty, C9437Roller Lever

Port Size Description Model Number

1/4" NPT Wall Mounted, Heavy Duty, CW9425Roller Lever

3/8" NPT Wall Mounted, Heavy Duty, CW9437Roller Lever

0

B

0

A

Normally OpenNormally Closed

A B

0

B

0

A

Normally OpenNormally Closed

A B

6

“C/CW” Series Valves3-Way, 2-Position

Catalog 0640-E/USA

Cam Operated Valves

Page 9: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

C13 & CW13 Cam C9 & CW9 Overriding Cam

ApplicationThese 3-Way, 2-Position, cam operated spool valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B” exhaust as a normally closed valve. Because of thearea-balanced construction of the spool, either port “A” or port“B” may be used as the inlet supply port. Pressure to port “A”valve is normally closed valve. Pressure to port “B” valve isnormally open valve.

ApplicationThese 3-Way, 2-Position, cam operated spool valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B” exhaust as normally closed valve. Because of the area-balanced construction of the spool, either port “A” or port “B”may be used as the inlet supply port. Pressure to port “A” valveis normally closed valve. Pressure to port “B” valve is normallyopen valve.

Model Selection Information

Port Size Description Model Number

1/4" NPT Base Mounted, Overriding Cam C9253/8" NPT Base Mounted, Overriding Cam C937

Port Size Description Model Number

1/4" NPT Wall Mounted, Overriding Cam CW9253/8" NPT Wall Mounted, Overriding Cam CW937

Model Selection Information

Port Size Description Model Number

1/4" NPT Base Mounted, Roller Cam C13253/8" NPT Base Mounted, Roller Cam C1337

Port Size Description Model Number

1/4" NPT Wall Mounted, Roller Cam CW13253/8" NPT Wall Mounted, Roller Cam CW1337

0

B

0

A

Normally OpenNormally Closed

A B

0

B

0

A

Normally OpenNormally Closed

A B

7

“C/CW” Series Valves3-Way, 2-Position

Catalog 0640-E/USA

Cam Operated Valves

DISC

ONT

INUE

D

Page 10: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

C5 CW5 C4 CW4

ApplicationThese 3-Way, 2-Position, hand operated spool valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B”. When hand lever is activated, port “A” is connected toport “0” and port “B” is blocked. Because of the area-balancedconstruction of the spool, either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” valve is normally open valve.

ApplicationThese 3-Way, 2-Position, hand operated spool valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationWith Hand Lever in Centered Position – Pressure at inlet port“A” is blocked and port “0” is connected to port “B” With thehand lever shifted to one place and locked, port “A” isconnected to port “0” and port “B” is blocked. Because of thearea-balanced construction of the spool, either port “A” or port“B” may be used as the inlet supply port. Pressure to port “A”valve is normally closed valve. Pressure to port “B” valve isnormally open valve.

Model Selection InformationPort Size Description Model Number

1/4'’ NPT Base Mounted, Hand Toggle, C525Locking

3/8" NPT Base Mounted, Hand Toggle, C537Locking

Port Size Description Model Number

1/4" NPT Wall Mounted, Hand Toggle, CW525Locking

3/8" NPT Wall Mounted, Hand Toggle, CW537Locking

Model Selection InformationPort Size Description Model Number

1/4" NPT Base Mounted, Hand Toggle, C425Non-Locking

3/8" NPT Base Mounted, Hand Toggle, C437Non-Locking

Port Size Description Model Number

1/4" NPT Wall Mounted, Hand Toggle, CW425Non-Locking

3/8" NPT Wall Mounted, Hand Toggle, CW437Non-Locking

0

BA

0

BA

Normally OpenNormally Closed

0

BA

0

BA

Normally OpenNormally Closed

8

“C/CW” Series Valves3-Way, 2-Position

Catalog 0640-E/USA

Hand Operated Valve

Page 11: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

!

Model Selection Information

Port Size Description Model Number

1/4" NPT Base Mounted, Palm Button C3253/8" NPT Base Mounted, Palm Button C337

Port Size Description Model Number

1/4" NPT Wall Mounted, Palm Button CW3253/8" NPT Wall Mounted, Palm Button CW337

C3 CW3 C6

ApplicationThese 3-Way, 2-Position, foot operated spool valves are used tooperate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingThese valves are designed for side ported, subbase mounting.

CAUTION:This valve shall not be used to actuate a punch press. Donot use this valve on punch presses or press brakes. SeeOSHA 1910.217.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B”. With foot pedal depressed, port “A” is connected to port“0” and port “B” is blocked. Because of the area-balancedconstruction of the spool, either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” valve is normally open valve.

ApplicationThese 3-Way, 2-Position, hand operated spool valves are usedto operate single acting cylinders. They can be usedas normally closed or normally open, and as a 2-Way.

MountingIntended for inline use. Use “C” Series for mounting tohorizontal surfaces. Use “CW” Series for mounting to verticalbulkheads.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” is blocked and port “0” is connected toport “B”. When button is depressed, port “A” is connected to port“0” and port “B” is blocked. Because of the area-balancedconstruction of the spool either port “A” or port “B” may be usedas the inlet supply port. Pressure to port “A” valve is normallyclosed valve. Pressure to port “B” valve is normally open valve.

0

BA

0

BA

Normally OpenNormally Closed

0

BA

0

BA

Normally OpenNormally Closed

9

“C/CW” Series Valves3-Way, 2-Position

Catalog 0640-E/USA

Hand & Foot Operated Valves

Model Selection Information

Port Size Description Model Number

1/4" NPT Base Mounted, Non-Locking C6253/8" NPT Base Mounted, Non-Locking C637 *

See Pedal Guard on following page.* Discontinued

Page 12: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

PS2043

ApplicationThis pedal guard is designed to protect the foot operated valvefrom accidental operation that may be caused by falling objectsor inadvertent contact.

CAUTION:This valve shall not be used to actuate a punch press.Do not use this valve on punch presses or press brakes.See OSHA 1910.217.

MountingMounting bolts for C6 Foot Valve are furnished in this Kit.

Model Selection Information

Description Part Number

Pedal Guard Kit PS2043

Operating Pressure2-Position Solenoid and Mechanical Valve:0 to 150 PSIG (0 to 1035 kPa)Also suitable for vacuum service.

2-Position Air Pilot Valve:0 to 150 PSIG (0 to 1035 kPa)Also suitable for vacuum service.Pilot pressures 30 to 150 PSI (207 to 1035 kPa).

Temperature0°F to 140°F (–18°C to 71°C)

Electrical Data: 120 Volt AC 60HzVoltage Range +10/-15% of NominalClass B

13.8 Watts 2.1 Amp Inrush .5 Amp Holding

Note: Coils are not intended for continuous duty

LubricationFiltered and lubricated air recommended for maximum life andminimum maintenance.

Flow Rating (Cv)

Flow PathValve Port Sizes

1/4" 3/8"A 0 2.1 2.5

0 A 2.0 2.2

B 0 1.9 2.0

0 B 2.1 2.3

Average 2.0 2.2

2-Position Single SolenoidAverage Fill Time: (Seconds)*

Valve 12 Cu. In. Test Chamber 100 Cu. In. Test ChamberPort Size Fill Exhaust Fill Exhaust

1/4" .027 .044 .184 .2693/8" .025 .040 .147 .235

* With 100 PSI supply, time required to fill from 0-90 PSI and exhaustfrom 100 PSI to 10 PSI is measured from instant of energizing, orde-energizing 120V/60Hz solenoid. Times shown are average.

10

“C/CW” Series Valves3-Way, 2-Position Technical Data

Catalog 0640-E/USA

Foot Operated Valve Pedal Guard

!

Page 13: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

C B

A

JK

F N

L

P

M

GE

AA

H

D(2 mtg. holes)

#6-32 Tap .25 deep4 holesY

Z

A

B

A

B

0

E

XA

B

0

.19 Travel+.02–.00

0

BU

A

JK

FS

R

QN

L

M

H

T

#6-32 Tap .25 deep4 holes

D(2 mtg.holes)

A

B

A

B

0

.19 Travel+.02–.00

Q

A

B

0

Base Mounted Valve Body

Basic Valve Dimensions

CJ1

CWJ1 Wall Mounted Valve Body

AA

YZ

0

VW

X

VW

“C/CW” Series Valves3-Way, 2-Position Single Solenoid Valve

Catalog 0640-E/USA

Dimensions

11

Dimensions:

A B C D E F G H J Kinches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D

mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø

L M N P Q R S T U Vinches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62 3.12

mm 18 4 59 6 19 13 14 54 41 79

W X Y Z AAinches 1.56 .67 3.60 1.94 5.72

mm 40 17 91 49 145

Page 14: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

W

V

1/8 NPT 1/8 NPT

A

B

0

A

B

0

C10 CW10

C B

A

F N

P

GE

H

D(2 mtg.holes)

A

B

A

B

0

B

B

B

U

A

FS

R

QN

H

T

D(2 mtg.holes)

A

B

A

B

0

C12

CW12

W

V

WY

WY

1/8 NPT

1/8 NPT

1/8 NPT

1/8 NPT

C B

A

JK

F N

L

P

M

GE

H

D(2 mtg.holes)

#6-32 Tap .25 deep4 holes

A

B

A

B

0

.19 Travel+.02–.00

BU

A

JK

FS

R

QN

L

M

H

T

#6-32 Tap .25 deep4 holes

D(2 mtg.holes)

A

B

A

B

0

.19 Travel+.02–.00

Base Mounted Valve Body

Basic Valve Dimensions

Wall Mounted Valve Body

12

“C/CW” Series Valves3-Way, 2-Position Remote Pressure Valve

Catalog 0640-E/USA

Dimensions

Dimensions:A B C D E F G H J K L

inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D .69

mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø 18

M N P Q R S T U V W Yinches .16 2.34 .25 .75 .50 .56 2.12 1.62 1.38 3.74 4.25

mm 4 59 6 19 13 14 54 41 35 95 108

Page 15: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic13

“C/CW” Series Valves3-Way, 2-Position Heavy Duty Cam Operated

Catalog 0640-E/USA

Dimensions

Basic Valve Dimensions

3.34

5.73 Max. OverallValve Length

Actuator MayBe Rotated 180

.25 Min. to Actuate

1.50 Dia.

Min. Travelto Actuate

2.001.34

.77.25

1.53

1.25

3535

3.34

5.73 Max. OverallValve Length

.25 Min.to Actuate

1.50Dia.

Min. Travelto Actuate

1.25

35

80 Max.Travel

.20

.50

C92 - CW92 Heavy Duty Overriding

Roller Lever

C94 - CW94Heavy DutyRoller Lever

80 Max.Travel

C B

A

JK

F N

L

P

M

GE

H

D(2 mtg. holes)

#6-32 Tap .25 deep4 holes

A

B

A

B

0

.19 Travel+.02–.00

BU

A

JK

FS

R

QN

L

M

H

T

#6-32 Tap .25 deep4 holes

D(2 mtg.holes)

A

B

A

B

0

.19 Travel+.02–.00

Base Mounted Valve Body

Wall Mounted Valve Body

Dimensions:A B C D E F G H J K

inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D

mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø

L M N P Q R S T Uinches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62

mm 18 4 59 6 19 13 14 54 41

Page 16: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic14

“C/CW” Series Valves3-Way, 2-Position Cam Operated

Catalog 0640-E/USA

Dimensions

1.83

1.00 Dia.

.19 Travel

4.19 Max. OverallValve Length

30° Max.Cam Angle

Operate

2.05

.50 Dia.

.19 Travel

4.41 Max. OverallValve Length

30° Max.Cam Angle

Operate

Non-Operate

C9 - CW9Overriding Cam

C13 - CW13Roller Cam

.19 Travel

1.41

3.77 Max. OverallValve Length

.62 Dia.

Note: Operates FromAny Direction

30° Max.Cam Angle

C2 - CW2Ball Cam

Cam Operated Basic Valve Dimensions

C B

A

JK

F N

L

P

M

GE

H

D(2 mtg. holes)

#6-32 Tap .25 deep4 holes

A

B

A

B

0

.19 Travel+.02–.00

BU

A

JK

FS

R

QN

L

M

H

T

#6-32 Tap .25 deep4 holes

D(2 mtg.holes)

A

B

A

B

0

.19 Travel+.02–.00

Base Mounted Valve Body

Wall Mounted Valve Body

Dimensions:A B C D E F G H J K

inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D

mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø

L M N P Q R S T Uinches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62

mm 18 4 59 6 19 13 14 54 41

Page 17: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

Hand Operated

1.03

1.31Dia. .19 Travel

3.39 Max. OverallValve Length

4.00

45

6.36Max. OverallValve Length

C3 - CW3Palm Button

C5 - CW5Hand Valve

Locking

4.00

36

6.36Max. OverallValve Length

Handle free to rotate 360 around vertical axis.

C4 - CW4Hand Valve

Non-Locking

Basic Valve Dimensions

C B

A

JK

F N

L

P

M

GE

H

D(2 mtg. holes)

#6-32 Tap .25 deep4 holes

A

B

A

B

0

.19 Travel+.02–.00

BU

A

JK

FS

R

QN

L

M

H

T

#6-32 Tap .25 deep4 holes

D(2 mtg.holes)

A

B

A

B

0

.19 Travel+.02–.00

Base Mounted Valve Body

Wall Mounted Valve Body

15

“C/CW” Series Valves3-Way, 2-Position Hand Operated Valve

Catalog 0640-E/USA

Dimensions

Dimensions:inches mm

A 1.19 30

B 1.06 27

C 2.06 52

D .28D 7Ø

E 1.28 33

F 1.12 28

G .72 18

H 2.56 65

J .20D 5.1Ø

K 1.00D 25.4Ø

Dimensions:inches mm

L .69 18

M .16 4

N 2.34 59

P .25 6

Q .75 19

R .50 13

S .56 14

T 2.12 54

U 1.62 41

Page 18: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

L

KM B

N

J

G

AH Travel

CD

F

C6 Non-Locking

D F1

B C

A

B1

A1

F

E

E1

Q

RP

S

A

B

A

B

0

Foot Valve GuardTo order foot valve guard, specify part number PS2043.This Kit contains the valve mounting hardware.

CAUTION:This valve shall not be used to actuate a punch press.Donot use this valve on punch presses or press brakes.See OSHA 1910.217.

16

“C/CW” Series Valves3-Way, 2-Position Foot Operated & Guard

Catalog 0640-E/USA

Dimensions

!

Dimensions:inches mm

A 4.12 105

B 3.16 80

C .88 22

D 1.75 44

F 4.22 107

G .16 4

H .59 15

J .94 24

K 2.62 67

L 1.31 33

M 2.06 52

N 2.56 65

P 2.19 56

Q 1.12 28

R 1.62 41

S .19 5

Dimensions:inches mm

A 4.50 114

A1 .75 19

B 10.50 267

B1 1.25 32

C .48 11

D 6.00 152

E 7.13 181

E1 .50 13

F 13.00 330

F1 8.38 213

Page 19: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic17

“C/CW” Series ValvesCatalog 0640-E/USA

Notes

Page 20: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

CCJ1 SeriesSingle Solenoid and Optional

Sandwich Flow Controls

Features

• 4-Way, 2-Position.

• Single and Double Solenoid(Direct Solenoid).

• Single and Double Air Pilot.

• Manual, cam, hand, and footoperators.

• Mounting: side ported base.

• Ports: 1/4 and 3/8 Inch.

• No minimum operating pressure(except air pilot).

• Cv 1.5

• Suitable for vacuum service.

• May be used as diverter.

• Available w/sandwich flow controls.

• Solenoid valves are CSA approved.AB

18

“CC” Series ValvesAir Control Valves

Catalog 0640-E/USA

Basic Valve Features

Page 21: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic19

“CC” Series ValvesAir Control Valves

Catalog 0640-E/USA

Model Number Index

Basic Valve Port Engineering Series Operator Options Size Level Coil Modification

CC J1 S 25 B 01 --

Valve Operators

Manual/Mechanical 2 Ball Cam, Spring Return 3 Palm Button, Spring Return 4 Hand Toggle, Non-locking 5 Hand Toggle, Locking 6 Non-Locking Foot Actuator 10 Remote Pressure, Spring Return 12 Double Remote Pressure 13 Roller Cam, Spring Return 92 Heavy Duty, Uni-Directional Roller

Lever, Spring Return 94 Heavy Duty, Bi-Directional Roller

Lever, Spring Return

ALTERNATING CURRENT SOLENOIDS J1 Single Solenoid, Spring Return,

Non-Locking Override J11 Double Solenoid, Momentary Contact

Coil - A.C. Solenoid

01 120V/60Hz

Modification

Blank None

Port Size

25 1/4" 37 3/8" VX Valve Assembly

Less Base

Options

Blank None S Sandwich Flow Control (CC Series Only)

Engineering Level

B Current

Note: Refer to back of Catalog for Cross Reference Information.

(Revised 04-06-11)

Page 22: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

Model Selection InformationFollowing model numbers are for 120V/60Hz.

Port Size Description Model Number

1/4" NPT Valve with Side Ported Subbase CCJ1125B013/8" NPT Valve with Side Ported Subbase CCJ1137B01

Following model numbers include the Integral Flow Control Section,120V/60Hz.

Port Size Description Model Number

1/4" NPT Valve with Side Ported Subbase CCJ11S25B013/8" NPT Valve with Side Ported Subbase CCJ11S37B01

Model Selection InformationFollowing model numbers are for 120V/60Hz.

Port Size Description Model Number

1/4" NPT Valve with Side Ported Subbase CCJ125B013/8" NPT Valve with Side Ported Subbase CCJ137B01

Following model numbers include the Integral Flow Control Section,120V/60Hz.

Port Size Description Model Number

1/4" NPT Valve with Side Ported Subbase CCJ1S25B013/8" NPT Valve with Side Ported Subbase CCJ1S37B01

ApplicationThese 4-Way, 2-Position direct solenoid operated (momentarycontact) spool valves are used to operate double actingcylinders. They may also be used as 2-Way or 3-Way valves byplugging appropriate ports.

MountingThese valves are designed for side ported, subbase mounting.

OperationSolenoid 1 Last Energized – Pressure at inlet port “A”connected to outlet port “02”. Outlet port “01” connected toexhaust port “B”.

Solenoid 2 Last Energized – Pressure at inlet port “A”connected to outlet port “01”. Outlet port “02” connected toexhaust port “B”. Because of the area-balanced construction ofthe spool, either port “A” or port “B” may be used as the inletsupply port.

Note: Because of direct Solenoid operation, both coils shouldnot be energized simultaneously.

ApplicationThese 4-Way, 2-Position direct solenoid operated, (maintainedcontact) spool valves are used to operate double actingcylinders. They may also be used as 2-Way or 3-Way valvesby plugging appropriate ports.

MountingThese valves are designed for side ported, subbase mounting.

OperationSolenoid De-energized – Port “A” is connected to port “02”,port “B” to port “01”. When solenoid is energized, port “A”connects to port “01”, port “B” to port “02”. Because of thearea-balanced construction of the spool, either port “A” orport “B” may be used as the inlet supply port.

CCJ1 Single Solenoid CCJ11 Double Solenoid

02 01

B A

02 01

B A

20

“CC” Series Valves4-Way, 4-Port, 2-Position

Catalog 0640-E/USA

Single & Double Solenoid Valves

Page 23: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Remote Pressure Return CC1225B3/8" NPT Side Ported, Remote Pressure Return CC1237B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Remote Pressure Return CC12S25B3/8" NPT Side Ported, Remote Pressure Return CC12S37B

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Spring Return CC1025B3/8" NPT Side Ported, Spring Return CC1037B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Spring Return CC10S25B3/8" NPT Side Ported, Spring Return CC10S37B

CC10 Single Air Pilot CC12 Double Air Pilot

ApplicationThese 4-Way, 2-Position remote pressure actuated, spoolvalves are used to operate double acting cylinders. They mayalso be used as 2-Way or 3-Way valves by plugging appropriateports. Valves are actuated by a “momentary” pressure signalalternately to each of the air pilot ports.

MountingThese valves are designed for side ported, subbase mounting.

OperationRemote Pressure at Piston Actuator #1 – Pressure at inletport “A” connected to outlet port “02”. Outlet port “01”connected to exhaust port “B”.

Remote Pressure at Piston Actuator #2 – Pressure at inletport “A” connected to outlet port “01”. Outlet port “02”connected to exhaust port “B”. Because of the area-balancedconstruction of the spool, either port “A” or port “B” maybe used as the inlet supply port.

ApplicationThese 4-Way, 2-Position remote pressure actuated, spoolvalves are used to operate double acting cylinders. They mayalso be used as 2-Way or 3-Way valves by plugging appropriateports. Valves are actuated by maintained pressure signal.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When pilot ispressurized, port “A” connects to “01” and port “B” to port “02”.Because of the area-balanced construction of the spool, eitherport “A” or port “B” may be used as the inlet supply port.

02 01

B A

21

“CC” Series Valves4-Way, 4-Port, 2-Position

Catalog 0640-E/USA

Remote Pressure Valves

02 01#1OperatorEnd

#2Operator

End

B A

Page 24: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic22

“CC” Series Valves4-Way, 4-Port, 2-Position

Catalog 0640-E/USA

Heavy Duty Cam Operated Valves

CC92 Heavy Duty Overriding Roller CC94 Heavy Duty Roller

ApplicationThese 4-Way, 2-Position, cam operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports. Theheavy duty roller operates in either direction.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When cam isactivated, pressure at inlet port “A” connects to outlet port “01”.Outlet port “02” connected to exhaust port “B”. Because ofthe area-balanced construction of the spool, either port “A”or port “B” may be used as the inlet supply port.

CC94 operates from either direction.

ApplicationThese 4-Way, 2-Position, cam operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports. Theheavy duty overriding roller operates in only one direction.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When cam isactivated, pressure at inlet port “A” connects to outlet port “01”.Outlet port “02” connected to exhaust port “B”. Because ofthe area-balanced construction of the spool, either port “A”or port “B” may be used as the inlet supply port.

CC92 is an overriding cam which operates in onedirection only.

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Heavy Duty, CC9225BOverriding Roller Lever

3/8" NPT Side Ported, Heavy Duty, CC9237BOverriding Roller Lever

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Heavy Duty, CC92S25BOverriding Roller Lever

3/8" NPT Side Ported, Heavy Duty, CC92S37BOverriding Roller Lever

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Heavy Duty, CC9425BRoller Lever

3/8" NPT Side Ported, Heavy Duty, CC9437BRoller Lever

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Heavy Duty, CC94S25BRoller Lever

3/8" NPT Side Ported, Heavy Duty, CC94S37BRoller Lever

02 01

B A

02 01

B A

Page 25: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic23

“CC” Series Valves4-Way, 4-Port, 2-Position

Catalog 0640-E/USA

Cam Operated Valves

CC9 Overriding Roller Cam CC13 Roller Cam

ApplicationThese 4-Way, 2-Position, cam operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports. The rolleroperates in either direction.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When cam isactivated, pressure at inlet port “A” connects to outlet port “01”.Outlet port “02” connected to exhaust port “B”. Because of thearea-balanced construction of the spool, either port “A” orport “B” may be used as the inlet supply port.

CC13 operates from either direction.

ApplicationThese 4-Way, 2-Position, cam operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports. Theoverriding roller operates in only one direction.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When cam isactivated, pressure at inlet port “A” connects to outlet port “01”.Outlet port “02” connected to exhaust port “B”. Because of thearea-balanced construction of the spool, either port “A” orport “B” may be used as the inlet supply port.

CC9 is an overriding cam which operates in onedirection only.

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Overriding Cam CC925B3/8" NPT Side Ported, Overriding Cam CC937B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Overriding Cam CC9S25B3/8" NPT Side Ported, Overriding Cam CC9S37B

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Roller Cam CC1325B3/8" NPT Side Ported, Roller Cam CC1337B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Roller Cam CC13S25B3/8" NPT Side Ported, Roller Cam CC13S37B

02 01

B A

02 01

B A

DISC

ONT

INUE

D

Page 26: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic24

“CC” Series Valves4-Way, 4-Port, 2-Position

Catalog 0640-E/USA

Cam & Hand Operated Valve

CC2 Cam Operated CC3 Hand Operated

ApplicationThese 4-Way, 2-Position, hand operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When handbutton is depressed, pressure at inlet port “A” connects tooutlet port “01”. Outlet port “02” connected to exhaust port “B”.Because of the area-balanced construction of the spool, eitherport “A” or port “B” may be used as the inlet supply port.

ApplicationThese 4-Way, 2-Position, cam operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When cam isactivated, pressure at inlet port “A” connects to outlet port “01”.Outlet port “02” connects to exhaust port “B”. Because of thearea-balanced construction of the spool, either port “A” orport “B” may be used as the inlet supply port.

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Ball Cam CC225B3/8" NPT Side Ported, Ball Cam CC237B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Ball Cam CC2S25B3/8" NPT Side Ported, Ball Cam CC2S37B

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Palm Button CC325B3/8" NPT Side Ported, Palm Button CC337B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Palm Button CC3S25B3/8" NPT Side Ported, Palm Button CC3S37B

02 01

B A

02 01

B A

Page 27: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic25

“CC” Series Valves4-Way, 4-Port, 2-Position

Catalog 0640-E/USA

Hand Operated Valves

CC4 Non-Locking CC5 Locking

ApplicationThese 4-Way, 2-Position, hand operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports. Valvesare manually operated and will remain in the last set positionwhen released.

MountingThese valves are designed for side ported, subbase mounting.

OperationWith Lever in Centered Position – Pressure at inlet port “A”connected to outlet port “02”. Outlet port “01” connected toexhaust port “B”. With the hand lever moved in either full upor full down position, pressure at inlet port “A” connects tooutlet port “01”. Outlet port “02” connected to exhaust port “B”.Because of the area-balanced construction of the spool, eitherport “A” or port “B” may be used as the inlet supply port.

ApplicationThese 4-Way, 2-Position, hand operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports. Valvesare actuated by maintained hand operation.

MountingThese valves are designed for side ported, subbase mounting.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”. Outletport “01” connected to exhaust port “B”. With hand lever movedin either full up or full down position, pressure at inlet port “A”connects to outlet port “01”. Outlet port “02” connected toexhaust port “B”. Because of the area-balanced constructionof the spool, either port “A” or port “B” may be used as theinlet supply port.

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Hand Toggle, CC525BLocking

3/8" NPT Side Ported, Hand Toggle, CC537BLocking

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Hand Toggle, CC5S25BLocking

3/8" NPT Side Ported, Hand Toggle, CC5S37BLocking

Model Selection Information

Port Size Description Model Number

1/4" NPT Side Ported, Hand Toggle, CC425BNon-Locking

3/8" NPT Side Ported, Hand Toggle, CC437BNon-Locking

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Side Ported, Hand Toggle, CC4S25BNon-Locking

3/8" NPT Side Ported, Hand Toggle, CC4S37BNon-Locking

02 01

B A

02 01

B A

Page 28: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic26

“CC” Series ValvesFoot Operated & Guard

Catalog 0640-E/USA

Foot Operated Valve & Pedal Guard

CC6 Foot Operated Valve PS2043 Pedal Guard

Model Selection Information

Port Size Description Model Number

1/4" NPT Rear Ported, Non-Locking CC625B3/8" NPT Rear Ported, Non-Locking CC637B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number

1/4" NPT Rear Ported, Non-Locking CC6S25B3/8" NPT Rear Ported, Non-Locking CC6S37B

Model Selection Information

Description Part Number

Pedal Guard PS2043

ApplicationThis pedal guard is designed to protect the foot operated valvefrom accidental operation that may be caused by falling objectsor inadvertent contact.

CAUTION:Foot valves utilizing this guard shall not be used to actuatea punch press. Do not use this valve on punch presses orpress brakes. See OSHA 1910.217.

MountingMounting bolts for CC6 Foot Valve, opposite, are furnishedin this kit.

ApplicationThese 4-Way, 2-Position, foot operated spool valves are usedto operate double acting cylinders. They may also be used as2-Way or 3-Way valves by plugging appropriate ports.

MountingThese valves are designed for side ported, subbase mounting.

CAUTION:This valve shall not be used to actuate a punch press.Do not use this valve on punch presses or press brakes.See OSHA 1910.217.

OperationDe-energized or Spring Returned Position of the Spool –Pressure at inlet port “A” connected to outlet port “02”.Outlet port “01” connected to exhaust port “B”. When pedal isdepressed, pressure at inlet port “A” connects to outlet port “01”.Outlet port “02” connects to exhaust port “B”. Because of thearea-balanced construction of the spool, either port “A” orport “B” may be used as the inlet supply port.

02 01

B A

!

!

Page 29: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

“CC” Series ValvesTechnical Data / CCJ1 Single Solenoid

Catalog 0640-E/USA

Technical Information / Dimensions

27

AB

J

DW/OF.C.

FG

DW/OF.C.

M

NP

Q

L

K

RS (2 mtg. holes)

1/2 NPSM

HE

N1

B1

W/F.C.

AA1

C

A

D1

W/F.C.

02 01

A B

CCJ1

Flow Rating (Cv)

Flow PathValve Port Sizes

1/4" 3/8"A 01 1.3 1.8

01 A 1.4 1.7

B 01 1.1 1.4

01 B 1.3 1.3

A 02 1.4 1.8

02 A 1.3 1.7

B 02 1.3 1.3

02 B 1.2 1.4

Average 1.3 1.5

Average Fill Time: (Seconds)*2-Position Single Solenoid

Valve 12 Cu. In. Test Chamber 100 Cu. In. Test ChamberSize Fill Exhaust Fill Exhaust

1/4" .034 .620 .028 .4113/8" .031 .630 .179 .385

2-Position Double Solenoid

Valve 12 Cu. In. Test Chamber 100 Cu. In. Test ChamberSize Fill Exhaust Fill Exhaust

1/4" .034 .620 .206 .4073/8" .030 .630 .177 .375

* With 100 PSI supply, time required to fill from 0-90 PSI and exhaustfrom 100 PSI to 10 PSI is measured from instant of energizing, orde-energizing 120V/60Hz solenoid. Times shown are average. Dimensions:

inches mm

A 6.25 159

A1 4.75 121

B 3.69 94

B1 4.28 109

C 3.12 79

D 2.56 65

D1 3.15 90

E 2.70 69

F .97 25

G .50 13

H 1.38 35

Dimensions:inches mm

J .59 15

K 1.19 30

L 2.56 65

M 2.06 52

N 1.56 40

N1 1.97 50

P 1.03 26

Q .25 06

R .81 21

S .28 7

Operating Pressure2-Position Solenoid and Mechanical Valve:0 to 150 PSIG (0 to 1035 kPa)Also suitable for vacuum service.

2-Position Air Pilot Valve:0 to 150 PSIG (0 to 1035 kPa)Also suitable for vacuum service.Pilot pressures 30 to 150 PSI (207 to 1035 kPa).

Temperature0°F to 160°F (–18°C to +71°C)

Electrical Data: 120 Volt AC 60HzVoltage Range +10/-15% of NominalClass B

13.8 Watts 2.1 Amp Inrush .5 Amp Holding

Note: Coils are not intended for continuous duty

LubricationFiltered and lubricated air recommended for maximum life andminimum maintenance.

Page 30: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic28

“CC” Series ValvesDouble Solenoid & Remote Pressure

Catalog 0640-E/USA

Dimensions

Dimensions:inches mm

A 9.50 241

B 3.78 96

B1 4.37 111

C 3.12 79

D 4.75 121

E 2.75 70

F .97 25

G .50 13

H 1.38 35

J .59 15

Dimensions:inches mm

K 1.19 30

L 2.56 65

M 2.06 52

N 1.56 40

N11.97 50max.

P 1.03 26

Q .25 06

S .28 07dia.

Dimensions:inches mm

A 3.00 76

A1 4.38 111

A2 5.76 146

B 2.56 65

B1 3.15 80

C 1.47 37min.

D .28 07

E 2.70 69

F .97 25

Dimensions:inches mm

G .50 13

H 1.35 34

J .59 15

K 1.19 30

L 2.56 65

M 2.06 52

N11.97 50max.

P 1.03 26

Q .25 06

J

FG

BW/OF.C.

M

NP

Q

L

K

S (2 mtg. holes)

1/2 NPSM

HE

N1

B1

W/F.C.

AD

A2

A

JK

HE

C

FG

NC

B1

W/F.C.

BW/OF.C.

02 01

B A

M

P

Q

L

D (2 mtg. holes)

02 01

B A

A1

A

JK

HE

FG

NC

B1

W/F.C.

BW/OF.C.

M

P

Q

L

D (2 mtg. holes)

02 01

B A

1/8 NPT

1/8 NPT2 Places

CC12

CC10

CCJ11

Pressure ActuatedDouble Solenoid

AB

AB

AB

Page 31: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic29

“CC” Series ValvesCam Operated Valve

Catalog 0640-E/USA

Dimensions

Dimensions:

A B B1 C D E F G H Jinches 3.00 2.56 3.15 1.47 min. .28 2.70 .987 .50 1.35 .59

mm 76 65 80 37 7 69 25 13 34 15

K L M N P Qinches 1.19 2.56 2.06 1.97 max. 1.03 .25

mm 30 65 52 50 26 6

A

3.34

6.34 Max. OverallValve Length

Actuator MayBe Rotated 180°

.25 Min.to Actuate

1.50 Dia.

Min. Travelto Actuate

JK

HE

FG

NC

B1

W/F.C.

BW/OF.C.

M

P

Q

L

D (2 mtg. holes)OperatorsAttach tothis Face

02 01

B A

1.83

1.00 Dia..19 Travel

2.001.34

.77

.25

1.53

4.83 Max. OverallValve Length

30° Max.Cam Angle

1.25

35°

35°

80° Max.Travel

3.34

6.34 Max. OverallValve Length

.25 Min.to Actuate

1.50 Dia.

Min. Travelto Actuate

1.25

35°

80° Max.Travel

.20.50 Operate

2.05

.50 Dia.

.19 Travel

5.05 Max. OverallValve Length

30° Max.Cam Angle

Operate

Non-Operate

CC9 Overriding Cam

CC92 Heavy Duty OverridingRoller Lever

CC94 Heavy DutyRoller Lever

CC13 Roller Cam

Valve Body

Basic Valve Dimensions

Cam OperatedHeavy Duty

AB

Page 32: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

A

JK

HE

FG

NC

B1

W/F.C.

BW/OF.C.

M

P

Q

L

D (2 mtg. holes)OperatorsAttach tothis Face

02 01

B A

1.03

1.31 Dia.

.19 Travel

.19 Travel

4.03 Max. OverallValve Length

1.41

4.41 Max. OverallValve Length

3.25 Approx.

6.25 Approx. OverallValve Length

.62 Dia. Ball

Note:Operates FromAny Direction

30° Max.Cam Angle

Neutral Position

CC4: 36° TravelEither Direction

CC5: 45° TravelEither Direction

CC2 Ball Cam

CC3 Palm Button

Valve Body

Basic Valve Dimensions

Cam OperatedHand Operated

CC4 Non-LockingCC5 Locking

AB

30

“CC” Series ValvesCam & Hand Operated

Catalog 0640-E/USA

Dimensions

Dimensions:inches mm

A 3.00 76

B 2.56 65

B1 3.15 80

C 1.47 37min.

D .28 7

E 2.70 69

F .97 25

G .50 13

H 1.35 34

J .59 15

K 1.19 30

L 2.56 65

M 2.06 52

N 1.97 50max.

P 1.03 26

Q .25 6

Page 33: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

R

Q

M

LJ K

C

E

B

D Travel

PN

FG

HA

W/OF.C.

A1

W/F.C.

EXH 02

01IN

CC6 Non-Locking

D F1

B C

A

B1

A1

F

E

E1

31

“CC” Series ValvesFoot Operated Valve & Pedal Guard

Catalog 0640-E/USA

Dimensions

Dimensions:inches mm

A 5.19 132

A1 5.77 147

B 4.12 105

C .94 24

D .59 15

E .16 4

F .88 22

G 1.75 44

H 4.22 107

J 2.06 52

K 3.16 80

L 2.62 67

M 1.31 33

N 1.09 28

P .55 14

Q 3.16 80

R 2.09 53

Dimensions:inches mm

A 4.50 114

A1 .75 19

B 10.50 267

B1 1.25 32

C .48 11

D 6.00 152

E 7.13 181

E1 .50 13

F 13.00 330

F1 8.38 213

Foot Valve GuardTo order foot valve guard, specify part number PS2043.This Kit contains the valve mounting hardware.

CAUTION:This valve shall not be used to actuate a punch press.Do not use this valve on punch presses or press brakes.See OSHA 1910.217.

!

Page 34: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

Description:• The Integral Flow Control Section can be used with

any CC Series Air Control Valve.

• The Flow Control Section, installed between valvebody and base, adds 5/8" to valve height.

• All parts are corrosion resistant.

• Exhaust air from each cylinder port is directedthrough a single valve exhaust port.

• Adjusting screws have extra fine threads andmetering tapers designed to provide accurate controlwithout extreme sensitivity.

OperationThe Integral Flow Control Section eliminates the need fortwo separate speed control valves. Air is exhausted througha single valve port, requiring only one muffler or pipedexhaust connection. Adjusting screws with fine threads havemetering tapers designed to give a wide range of controlwithout extreme sensitivity. Adjustment is made with anordinary screwdriver; friction-lock prevents changes insetting due to vibration.

The Flow Control Section has been designed to give “Meter-Out” control of exhaust air flowing FROM Cylinder TO ValveExhaust Port. For best results, air supply to valve must beconnected to port “A”. Lines from cylinder ports on valve toports on cylinder should be kept as short as possible toreduce “jump” of the cylinder piston when valve shifts.However, it is possible to connect air supply to port “B” whichresults in “Meter-In” control of air supply to cylinder.

The unit can be installed on any CC Series valve already inuse by removing the cap screws that fasten the valve bodyassembly to the base, inserting the Flow Control Sectionand the gasket between the body and base, and securingthe three components together with the longer cap screwsprovided. Installation is accomplished without disturbing anyelectrical or piping connections. Provision is made to preventimproper mounting by means of the locating pin, thusconforming to J.l.C. recommendations.

Ordering InformationTo order “CC” Valves equipped with the Integral FlowControl Section, see “Model Selection Information” onprevious pages.

To order the Integral Flow Control Section Kitseparately, specify:

• Flow Control Section Kit – PL504000.

Flow Control Section Installed

Integral Flow Control Section

Flow Ratings (Cv)

Flow Valve Port Size Flow Valve Port Size

Path Path1/4" 3/8" 1/4" 3/8"

A 01 1.63 1.85 A 02 1.66 1.89

01 A 1.57 1.74 02 A 1.49 1.75

B 01 .81 .98 B 02 .87 .95

01 B .95 .98 02 B 1.05 1.04

When piped for meter-out control, as metering screws areturned in, Cv from cylinder port to exhaust is reduced. Cv frominlet to cylinder port remains unchanged.

A

B

DC

E

32

“CC” Series ValvesFlow Control Section

Catalog 0640-E/USA

Options

Dimensions:inches mm

A 2.70 69

B 2.12 54

C .28 7

D .78 20

E .56 14

Page 35: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

“C/CW/CC” Series ValvesCatalog 0640-E/USA

Cross Reference

33

C325M1 C325 Standard size button PL502600

C337M1 C337 Standard size button PL502600

C525M4 C525 Straight handle, locking PL5379

C525M6 C525 Straight handle, locking PL5379

C537M6 C537 Straight handle, locking PL5379

C725 C625 Foot Actuator non-locking PL502500

C737 C637 Foot Actuator non-locking PL502500

C925 C9225 Heavy Duty Overriding Cam Unidirectional 1/4" ports PL502600

C937 C9237 Heavy Duty Overriding Cam Unidirectional 3/8" ports PL502600

CC125B01M8 Use service kit. PL503500

CC325BM1 CC325B Standard size button PL503300

CC337BM1 CC337B Standard size button PL503300

CC3VXBM1 CC3VXB Standard size button PL503300

CC525BM3 CC525B Straight handle, locking PL503300

CC537BM3 CC537B Straight handle, locking PL503300

CC5S25BM3 CC5S25B Straight handle, locking PL503300

CC5VXBM3 CC5VXB Straight handle, locking PL503300

CC5VXBM7 CC5VXB Straight handle, locking PL503300

CC725B CC625B Foot Actuator non-locking PL503300

CC737B CC637B Foot Actuator non-locking PL503300

CC7S25B CC6S25B Foot Actuator non-locking PL503300

CC925B CC9225B Heavy Duty Overriding Cam Unidirectional 1/4" ports PL503300

CC937B CC9237B Heavy Duty Overriding Cam Unidirectional 3/8" ports PL503300

CC9S25B CC92S25B Heavy Duty Overriding Cam Unidirectional 1/4" ports PL503300

CCJ1125B02 PL503200

CCJ1137B01M11 Use service kit. PL5450

CCJ1137B01M28 Use service kit. PL5450

CCJ1137B02 F5215BGC87A Dbl Sol 240vac Valve 3/8" npt PL503200

CCJ11S37B01M11 Use service kit. PL5450

CCJ11S37B01M28 Use service kit. PL5450

CCJ11S37B02 CCJ11S37B01 240 VAC Coils not available, use 120 VAC PL503200

CCJ11S37B06 F5215BGC19001A Dbl Sol 24vdc Valve w/ sandwich flow control PL503200

CCJ125B01M28 Use service kit. PL5450

CCJ125B02 F5E13BGC87A Sgl Sol 240vac valve 1/4 npt PL503000

CCJ125B06 F5E13BGC87A Sgl Sol 24vdc valve 1/4 npt PL503000

CCJ125B15 F5E13BGC23A Sgl Sol 115vac 50hz 1/4 npt PL503000

CCJ125B24 F5E13BGC87A Sgl Sol 230vac/50hz 1/4npt PL503000

CCJ137B02 F5E15BGC87A Sgl Sol 240vac valve 3/8 npt PL503000

CCJ137B15 F5E15BGC23A Sgl Sol 115vac 50hz 3/8 npt PL503000

CCJ137B24 F5E15BGC87A Sgl Sol 230vac/50hz 3/8npt PL503000

CCJ1S25B02 F5E13BGC87001A Sgl Sol 240vac valve 1/4 npt w/ flow control PL503000

CCJ1S25B03 Use service kit. PL503000

CCJ1S37B01M28 Use service kit. PL5450

CCJ1S37B02 F5E15BGC87001A Sgl Sol 240vac valve 3/8 npt w/ flow control PL503000

Obsolete FunctionalPart Number Replacement Description / Notes Valve Service Kits

Page 36: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

“C/CW/CC” Series ValvesCatalog 0640-E/USA

Cross Reference

34

CCJ1SVXB15 Use service kit. PL503000

CCJ1SVXB24 Use service kit. PL503000

CCJ1VXB24 Use service kit. PL503000

CCJY00004 Use service kit. PL5450

CCJY00005 Use service kit. PL5450

CCJY00007 Use service kit. PL5450

CJ12502 F5E13BGC87A Sgl Sol 240vac valve 1/4 npt PL502600

CJ12506 F5E13BGC19A Sgl Sol 24vdc valve 1/4 npt PL502600

CJ12524 F5E13BGC87A Sgl Sol 230vac/50hz 1/4npt PL502600

CJ13701M16 CJ13701 72" leads no longer available, standard w/ 6" leads PL502600

CJ13701M19 See notes Class H coil no longer available PL502600

CJ13702 F5E15BGC87A Sgl Sol 240vac valve 3/8 npt PL502600

CJ13706 F5E15BGC19A Sgl Sol 24vdc valve 3/8 npt PL502600

CJ13715 F5E15BGC23A Sgl Sol 115vac 50hz 3/8 npt PL502600

CJ13724 F5E15BGC87A Sgl Sol 230vac/50hz 3/8 npt PL502600

CW1025M6 CW1025 PL502700

CW13705DC n/a 125VDC not available review application n/a

CW325M1 CW325 Standard size button PL502600

CW337M1 CW337 Standard size button PL502600

CW437M3 CW437 Straight handle, locking PL502600

CW525M3 CW525 Straight handle, locking PL502600

CW925 CW9225 Heavy Duty Overriding Cam Unidirectional 1/4" ports PL502600

CW937 CW9237 Heavy Duty Overriding Cam Unidirectional 3/8" ports PL502600

CWJ12502 B5G1BCH57C B series inline 1/4" npt PL502600

CWJ13702 B5G2BCH57C B series inline 3/8" npt PL502600

CWS125 Use service kit. PL502800

CWS137 Use service kit. PL502800

CWY00005 CW1325 Steel roller instead of Nylon. PL502600

CWY00010 CW9437M28 Nylon roller instead of Steel PL5379

CWY00011 None Review Application PL5379

CWY00012 None Review Application PL5379

CWY00013 None Review Application PL5379

CY00004 Use service kit. PL5379

CY00007 CJ12501 Not available for high temp service PL502600

CY00008 CJ13701 Not available for high temp service PL502600

CY00010 C537 Not available for high temp service PL5379

Obsolete FunctionalPart Number Replacement Description / Notes Valve Service Kits

Page 37: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic35

Catalog 0640-E/USA

Offer Of Sale

The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries andits authorized distributors, are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and itsauthorized distributors. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms andConditions. Buyer’s order for any such item, when communicated to Parker Hannifin Corporation, its subsidiaries or an authorizeddistributor (“Seller”) verbally or in writing, shall constitute acceptance of this offer.

1. Terms and Conditions of Sale: All descriptions, quotations,proposals, offers, acknowledgments, acceptances and sales of Seller’sproducts are subject to and shall be governed exclusively by the termsand conditions stated herein. Buyer’s acceptance of any offer to sell islimited to these terms and conditions. Any terms or conditions in additionto, or inconsistent with those stated herein, proposed by Buyer in anyacceptance of an offer by Seller, are hereby objected to. No suchadditional, different or inconsistent terms and conditions shall becomepart of the contract between Buyer and Seller unless expressly acceptedin writing by Seller. Seller’s acceptance of any offer to purchase byBuyer is expressly conditional upon Buyer’s assent to all the terms andconditions stated herein, including any terms in addition to, or inconsistentwith those contained in Buyer’s offer. Acceptance of Seller’s productsshall in all events constitute such assent.2. Payment: Payment shall be made by Buyer net 30 days from the dateof delivery of the items purchased hereunder. Amounts not timely paidshall bear interest at the maximum rate permitted by law for each monthor portion thereof that the Buyer is late in making payment. Any claimsby Buyer for omissions or shortages in a shipment shall be waivedunless Seller receives notice thereof within 30 days after Buyer’s receiptof the shipment.3. Delivery: Unless otherwise provided on the face hereof, deliveryshall be made F.O.B. Seller’s plant. Regardless of the method ofdelivery, however, risk of loss shall pass to Buyer upon Seller’s deliveryto a carrier. Any delivery dates shown are approximate only and Sellershall have no liability for any delays in delivery.4. Warranty: Seller warrants that the items sold hereunder shall be freefrom defects in material or workmanship for a period of 18 months fromdate of shipment from Parker Hannifin Corporation. THIS WARRANTYCOMPRISES THE SOLE AND ENTIRE WARRANTY PERTAININGTO ITEMS PROVIDED HEREUNDER. SELLER MAKES NO OTHERWARRANTY, GUARANTEE, OR REPRESENTATION OF ANY KINDWHATSOEVER. ALL OTHER WARRANTIES, INCLUDING BUT NOTLIMITED TO, MERCHANTABILITY AND FITNESS FOR PURPOSE,WHETHER EXPRESS, IMPLIED, OR ARISING BY OPERATION OFLAW, TRADE USAGE, OR COURSE OF DEALING ARE HEREBYDISCLAIMED.NOTWITHSTANDING THE FOREGOING, THERE ARE NOWARRANTIES WHATSOEVER ON ITEMS BUILT OR ACQUIREDWHOLLY OR PARTIALLY, TO BUYER’S DESIGN ORSPECIFICATIONS.5. Limitation of Remedy: SELLER’S LIABILITY ARISING FROM ORIN ANY WAY CONNECTED WITH THE ITEMS SOLD OR THISCONTRACT SHALL BE LIMITED EXCLUSIVELY TO REPAIR ORREPLACEMENT OF THE ITEMS SOLD OR REFUND OF THEPURCHASE PRICE PAID BY BUYER, AT SELLER’S SOLE OPTION.IN NO EVENT SHALL SELLER BE LIABLE FOR ANY INCIDENTAL,CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND ORNATURE WHATSOEVER, INCLUDING BUT NOT LIMITED TO LOSTPROFITS ARISING FROM OR IN ANY WAY CONNECTED WITHTHIS AGREEMENT OR ITEMS SOLD HEREUNDER, WHETHERALLEGED TO ARISE FROM BREACH OF CONTRACT, EXPRESSOR IMPLIED WARRANTY, OR IN TORT, INCLUDING WITHOUTLIMITATION, NEGLIGENCE, FAILURE TO WARN OR STRICTLIABILITY.6. Changes, Reschedules and Cancellations: Buyer may request tomodify the designs or specifications for the items sold hereunder as wellas the quantities and delivery dates thereof, or may request to cancel allor part of this order, however, no such requested modification orcancellation shall become part of the contract between Buyer and Sellerunless accepted by Seller in a written amendment to this Agreement.Acceptance of any such requested modification or cancellation shall beat Seller’s discretion, and shall be upon such terms and conditions asSeller may require.7. Special Tooling: A tooling charge may be imposed for any specialtooling, including without limitations, dies, fixtures, molds and patterns,acquired to manufacture items sold pursuant to this contract. Suchspecial tooling shall be and remain Seller’s property notwithstandingpayment of any charges by Buyer. In no event will Buyer acquire anyinterest in apparatus belonging to Seller which is utilized in themanufacture of the items sold hereunder, even if such apparatus hasbeen specially converted or adapted for such manufacture andnotwithstanding any charges paid by Buyer. Unless otherwise agreed,Seller shall have the right to alter, discard or otherwise dispose of any

special tooling or other property in its sole discretion at any time.8. Buyer’s Property: Any designs, tools, patterns, materials, drawings,confidential information or equipment furnished by Buyer, or any otheritems which become Buyer’s property, may be considered obsolete andmay be destroyed by Seller after two (2) consecutive years haveelapsed without Buyer placing an order for the items which aremanufactured using such property. Seller shall not be responsible forany loss or damage to such property while it is in Seller’s possessionor control.9. Taxes: Unless otherwise indicated on the face hereof, all prices andcharges are exclusive of excise, sales, use, property, occupational orlike taxes which may be imposed by any taxing authority upon themanufacture, sale or delivery of the items sold hereunder. If any suchtaxes must be paid by Seller or if Seller is liable for the collection of suchtax, the amount thereof shall be in addition to the amounts for the itemssold. Buyer agrees to pay all such taxes or to reimburse Seller thereforeupon receipt of its invoice. If Buyer claims exemption from any sales,use or other tax imposed by any taxing authority, Buyer shall save Sellerharmless from and against any such tax, together with any interest orpenalties thereon which may be assessed if the items are held to betaxable.10. Indemnity For Infringement of Intellectual Property Rights:Seller shall have no liability for infringement of any patents, trademarks,copyrights, trade dress, trade secrets or similar rights except asprovided in this Part 10. Seller will defend and indemnify Buyer againstallegations of infringement of U.S. patents, U.S. trademarks, copyrights,trade dress and trade secrets (hereinafter “Intellectual Property Rights”).Seller will defend at its expense and will pay the cost of any settlementor damages awarded in an action brought against Buyer based on anallegation that an item sold pursuant to this contract infringes theIntellectual Property Rights of a third party. Seller’s obligation to defendand indemnify Buyer is contingent on Buyer notifying Seller within ten(10) days after Buyer becomes aware of such allegations of infringement,and Seller having sole control over the defense of any allegations oractions including all negotiations for settlement or compromise. If anitem sold hereunder is subject to a claim that it infringes the IntellectualProperty Rights of a third party, Seller may, at its sole expense andoption, procure for Buyer the right to continue using said item, replaceor modify said item so as to make it noninfringing, or offer to acceptreturn of said item and return the purchase price less a reasonableallowance for depreciation. Notwithstanding the foregoing, Seller shallhave no liability for claims of infringement based on information providedby Buyer, or directed to items delivered hereunder for which the designsare specified in whole or part by Buyer, or infringements resulting fromthe modification, combination or use in a system of any item soldhereunder. The foregoing provisions of this Part 10 shall constituteSeller’s sole and exclusive liability and Buyer’s sole and exclusiveremedy for infringement of Intellectual Property Rights.If a claim is based on information provided by Buyer or if the design foran item delivered hereunder is specified in whole or in part by Buyer,Buyer shall defend and indemnify Seller for all costs, expenses orjudgements resulting from any claim that such item infringes any patent,trademark, copyright, trade dress, trade secret or any similar right.11. Force Majeure: Seller does not assume the risk of and shall not beliable for delay or failure to perform any of Seller’s obligations by reasonof circumstances beyond the reasonable control of Seller (hereinafter“Events of Force Majeure”). Events of Force Majeure shall includewithout limitation, accidents, acts of God, strikes or labor disputes, acts,laws, rules or regulations of any government or government agency,fires, floods, delays or failures in delivery of carriers or suppliers,shortages of materials and any other cause beyond Seller’s control.12. Entire Agreement/Governing Law: The terms and conditions setforth herein, together with any amendments, modifications and anydifferent terms or conditions expressly accepted by Seller in writing,shall constitute the entire Agreement concerning the items sold, andthere are no oral or other representations or agreements which pertainthereto. This Agreement shall be governed in all respects by the law ofthe State of Ohio. No actions arising out of sale of the items soldhereunder or this Agreement may be brought by either party more thantwo (2) years after the cause of action accrues.

Page 38: Air Control Valves 3-Way, 3-Port, 2-Position 4-Way, 4-Port, 2-Position · 2014-12-11 · 4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure .....28 4-Way, 4-Port, 2-Position

Parker Hannifin CorporationPneumatic Division8676 E. M89P.O. Box 901Richland, MI 49083 USATel: (269) 629-5000Fax: (269) 629-5385

Customer/Technical Service

Tel: (269) 629-5575Fax: (269) 629-5385Web site: www.parker.com/pneumaticE-mail: [email protected]

Catalog 0640-E/USA 04/04 IGS Printed in U.S.A.