5
AEG 36 TYPE LS AC CONTACTORS OPEN LS07.10 -!0 $34 LS4.10 -!0 $90 LS7.10 -!0 $115 LS17.10 -!0 $130 LS27.22# -!0 $145 LS37.22# -!0 $173 LS47.22 -!0 $240 LS57.22 -!0 $290 Size M I N I 00 0 0+ 1+ 1 3/4 2 2 1/2 Horse Power Ratings 3 Phase Motor Max Volts HP 200V 3 HP 230V 3 HP 460V 3 HP LIST 200V 3 HP 230V 3 HP 460V 7.5 HP 600V 7.5 HP LIST 200V 5 HP 230V 5 HP 460V 10 HP 600V 10 HP LIST 200V 5 HP 230V 7.5 HP 460V 10 HP 600V 15 HP LIST 200V 7.5 HP 230V 10 HP 460V 15 HP 600V 20 HP LIST 200V 10 HP 230V 10 HP 460V 25 HP 600V 25 HP LIST 200V 15 HP 230V 20 HP 460V 40 HP 600V 50 HP LIST 200V 20 HP 230V 25 HP 460V 50 HP 600V 60 HP LIST Inductive Resistive 10 A 16 A 16 A 20 A 20 A (T) 25 A 27A 30 A 40 A (T) 55 A 62.5 A 90 A 110 A 100 A 150 A NEMA 1 General Purpose LS07.10 -!1 $60 LS4.10 -!1 $116 LS7.10 -!1 $141 LS17.10 -!1 $156 LS27.22 -!1 $171 LS37.22 -!1 $222 LS47.22 -!1 $289 LS57.22 -!1 $339 NEMA 4X$ Outdoor Dust Tight LS07.10 -!4X $124 LS4.10 -!4X $161 LS7.10 -!4X $186 LS17.10 -!4X $201 LS27.22 -!4X $216 LS37.22 -!4X $301 LS47.22 -!4X $376 LS57.22 -!4X $426 NEMA 12 Dust Tight LS07.10 -!12 $126 LS4.10 -!12 $163 LS7.10 -!12 $188 LS17.10 -!12 $203 LS27.22 -!12 $218 LS37.22 -!12 $337 LS47.22 -!12 $419 LS57.22 -!12 $469 NEMA 7 Hazard Area - - - - - - - - - - - - LS27.22 -!7 Contact Factory LS37.22 -!7 Contact Factory LS47.22 -!7 Contact Factory LS57.22 -!7 Contact Factory NEMA 4 Metal LS07.10 -!4 $194 LS4.10 -!4 $295 LS7.10 -!4 $320 LS17.10 -!4 $335 LS27.22 -!4 $350 LS37.22 -!4 $663 LS47.22 -!4 $705 LS57.22 -!4 $755 Comparable NEMA HP 200 V 1.5 HP 230 V 1.5 HP 460 V 2 HP 600 V 2 HP NEMA Size 00 200 V 3 HP 230 V 3 HP 460 V 5 HP 600 V 5 HP NEMA Size 0 200 V 7.5 HP 230 V 7.5 HP 460 V 10 HP 600 V 10 HP NEMA Size 1 200 V 10 HP 230 V 15 HP 460 V 25 HP 600 V 25 HP NEMA Size 2 THREE POLE CONTACTORS NEMA RATED 4 pole and N.C. Pole see page AEG 64 ENCLOSED ! COIL VOLTAGE SUFFIX AC! 60HZ 50HZ -A 120V 110V -C 208V/230V 220V -E 480V 440V -F 600V 550V -D 380V -G 24V 22V -H 280V/277V 240V DC! -MTW 12VDC -NTW 24VDC -OTW 48VDC -PTW 120VDC -RTW 220VDC Price Addition for DC Coil. TYPE 4X ENCLOSED STARTERS Type 4X enclosed starters are UL/CSA Listed. AUXILIAR Y CONT ACTS 1 N.O. Standard LS07-LS17 2 N.O. + 2 N.C. Standard LS27-LS450K For Additional Auxilixries, see page AEG 24. #Option, with no auxiliaries (supplied with Power Poles Only, without auxiliaries). LS27.00 -* 0 $133 List LS37.00 -* 0 $155 List $ # (T) Also Tungsten Rating to 277 Volt (UL) TYPICAL ORDER ITEM 5HP 20A Contactor LS4- AO Open Coil 120Volts SW: Single Winding D.C. Coil LS07.10, add $10 list each. For single winding D.C. coils see page AEG 8. TW: Two Winding D.C. Coil. Add $25 list each, for sizes LS4 thru LS77. Add $50 list each for sizes LS87 thru LS247. Discount Schedule ST For Modifications & Field Kits See Page AEG 33. CONTACTORS

AEG contactors

Embed Size (px)

Citation preview

Page 1: AEG contactors

AEG 36

TYPE LSAC CONTACTORS

OPEN

LS07.10-!0$34

LS4.10-!0

$90

LS7.10

-!0

$115

LS17.10-!0

$130

LS27.22#

-!0

$145

LS37.22#

-!0

$173

LS47.22-!0

$240

LS57.22-!0

$290

Size

MI

NI

00

0

0+

1+

13/4

2

21/2

Horse PowerRatings

3 Phase

Motor MaxVolts HP200V 3 HP230V 3 HP460V 3 HPLIST200V 3 HP230V 3 HP460V 7.5 HP600V 7.5 HPLIST200V 5 HP230V 5 HP460V 10 HP600V 10 HPLIST200V 5 HP230V 7.5 HP460V 10 HP600V 15 HPLIST200V 7.5 HP230V 10 HP460V 15 HP600V 20 HPLIST 200V 10 HP230V 10 HP460V 25 HP600V 25 HPLIST200V 15 HP230V 20 HP460V 40 HP600V 50 HPLIST200V 20 HP230V 25 HP460V 50 HP600V 60 HPLIST

Indu

ctiv

eR

esis

tive

10 A

16 A

16 A

20 A

20 A

(T)

25 A

27A

30 A

40 A

(T)

55 A

62.5

A90

A11

0 A

100

A15

0 A

NEMA 1GeneralPurpose

LS07.10-!1$60

LS4.10-!1

$116

LS7.10

-!1

$141

LS17.10-!1

$156

LS27.22

-!1

$171

LS37.22

-!1

$222

LS47.22-!1

$289

LS57.22-!1

$339

NEMA 4X$OutdoorDust Tight

LS07.10-!4X$124

LS4.10-!4X

$161

LS7.10

-!4X

$186

LS17.10-!4X

$201

LS27.22

-!4X

$216

LS37.22

-!4X

$301

LS47.22-!4X

$376

LS57.22-!4X

$426

NEMA 12Dust Tight

LS07.10-!12$126

LS4.10-!12

$163

LS7.10

-!12

$188

LS17.10-!12

$203

LS27.22

-!12

$218

LS37.22

-!12

$337

LS47.22-!12

$419

LS57.22-!12

$469

NEMA 7HazardArea

---

--

-

-

-

-

--

-

LS27.22

-!7ContactFactory

LS37.22

-!7ContactFactory

LS47.22-!7

ContactFactory

LS57.22-!7

ContactFactory

NEMA 4Metal

LS07.10-!4$194

LS4.10-!4

$295

LS7.10

-!4

$320

LS17.10-!4

$335

LS27.22

-!4

$350

LS37.22

-!4

$663

LS47.22-!4

$705

LS57.22-!4

$755

ComparableNEMA HP

200 V 1.5 HP230 V 1.5 HP460 V 2 HP600 V 2 HPNEMA Size 00

200 V 3 HP230 V 3 HP460 V 5 HP600 V 5 HPNEMA Size 0

200 V 7.5 HP230 V 7.5 HP460 V 10 HP600 V 10 HPNEMA Size 1

200 V 10 HP230 V 15 HP460 V 25 HP600 V 25 HPNEMA Size 2

THREE POLE CONTACTORSNEMA RATED4 pole and N.C. Pole see page AEG 64

ENCLOSED

! COIL VOLTAGE SUFFIXAC! 60HZ 50HZ-A 120V 110V-C 208V/230V 220V-E 480V 440V-F 600V 550V-D 380V-G 24V 22V-H 280V/277V 240VDC! •-MTW 12VDC-NTW 24VDC-OTW 48VDC-PTW 120VDC-RTW 220VDC

•PriceAdditionfor DCCoil.

TYPE 4X ENCLOSED STARTERSType 4X enclosed starters are UL/CSA Listed.

AUXILIARY CONTACTS1 N.O. Standard LS07-LS172 N.O. + 2 N.C. Standard LS27-LS450KFor Additional Auxilixries, see page AEG 24. #Option, with no auxiliaries (supplied withPower Poles Only, without auxiliaries).

LS27.00 -* 0 $133 ListLS37.00 -* 0 $155 List

$

#

(T) Also Tungsten Rating to 277 Volt (UL)

TYPICAL ORDER ITEM5HP 20A Contactor

LS4- AO

OpenCoil 120Volts

• SW: Single Winding D.C. Coil LS07.10, add $10 listeach. For single winding D.C.coils see page AEG 8.

• TW: Two WindingD.C. Coil. Add $25 list each,for sizes LS4 thru LS77. Add $50 list each for sizes LS87 thru LS247.

Discount Schedule ST

For Modifications & Field Kits See Page AEG 33.

CO

NTA

CTO

RS

Page 2: AEG contactors

AEG 37

TYPE LSAC CONTACTORS

OPEN

LS77.22-!0

$380

LS87.22-!0

$470

LS107.22

-!0

$850

LS177.22-!0

$1,164

LS247.22-!0

$1,564

LS220K.22

-!0

$2,150

LS280K.22-!0

$3,100

LS375K.22-!0

$3,900

Size

3

31/2

4

41/2

5

51/2

6

61/2

Horse PowerRatings

3 Phase

Motor MaxVolts HP200V 25 HP230V 30 HP460V 60 HP600V 75 HPLIST200V 30 HP230V 40 HP460V 75 HP600V 100 HPLIST200V 40 HP230V 50 HP460V 100 HP600V 100 HPLIST200V 60 HP230V 75 HP460V 150 HP600V 200 HPLIST200V 75 HP230V 100 HP460V 200 HP600V 250 HPLIST 200V 125 HP230V 150 HP460V 300 HP600V 400 HPLIST200V 150 HP230V 200 HP460V 400 HP600V 500 HPLIST230V 250 HP460V 500 HP600V 600 HPLIST

Indu

ctiv

eR

esis

tive

110

A15

0 A

150

A18

0 A

200

A22

5 A

320

A35

0 A

500

A60

0 A

650

A70

0 A

NEMA 1GeneralPurpose

LS77.22-!1

$461

LS87.22-!1

$666

LS107.22

-!1

$954

LS177.22-!1

$1,476

LS247.22-!1

$1,876

LS220K.22

-!1

$3,450

LS280K.22-!1

$4,400

LS375K.22-!1

$5,200

NEMA 4X$OutdoorDust Tight

LS77.22-!4X

$539

LS87.22-!4X

$1,185

LS107.22

-!4X

$1,565

LS177.22-!4X

$1,996

LS247.22-!4X

$2,296

LS220K.22-!4X

$3,710

LS280K.22-!4X

$4,660

NEMA 12Dust Tight

LS77.22-!12$591

LS87.22-!12

$1,215

LS107.22

-!12

$1,604

LS177.22-!12

$2,126

LS247.22

-!12

$2,426

LS220K.22-!12

$3,970

LS280K.22

-!12

$4,920

NEMA 4Metal

LS77.22-!4

$877

LS87.22-!4

$1,685

LS107.22-!4

$1,865

LS177.22-!4

$2,594

LS247.22-!4

$2,894

LS220K.22

-!4

$5,738

LS280K.22-!4

$8,300

ComparableNEMA HP

NEMA RATED

ENCLOSED

110

A15

0 A

810

A10

00 A

NEMA 7Hazard

Area

LS77.22-!7

Contact Factory

LS87.22-!7

Contact Factory

LS107.22

-!7

Contact Factory

LS177.22-!7

Contact Factory

LS247.22-!7

Contact Factory

LS220K.22-!7

Contact Factory

LS280K.22

-!7

Contact Factory

30 Amp Power Auxiliary. (600 Volt)See page AEG 24.

For 4 pole and N.C. Pole Contactors, thru 1250 Amp,see “K” Contactors section.

CONTACTORS ARE STOCK THROUGH 1250 AMPSEXAMPLE OF DOLLAR SAVINGS WITH AEG CONTACTORS

50 HP 460 VOLT LOADEEC PART# LS57 $290.00 LISTCOMPETITOR NEMA SIZE 3 $600.00 LISTDOLLAR SAVINGS $310.00 LIST

POSITIVE GUIDED VERSIONS AVAILABLEWITH 2 NO / 2NC AUX. FOR SAFETY CIRCUITS

P/N

LS4.22-*LS7.22-*LS17.22-*LS27.22-*LS37.22-*LS47.22-*

LIST

$115.00$125.00$135.00$145.00$173.00$240.00

AUXILIARIES SUPPLIED AS STANDARD1 NO

LS07.10LS4.10LS7.10LS17.10

2 NO / 2 NC

LS27.22LS37.22LS47-LS247.22LS220K-LS375K.22

Discount Schedule ST

200V 75 HP230V 100 HP460V 200 HP600V 200 HPNEMA 5

200V 40 HP230V 50 HP460V 100 HP600V 100HPNEMA 4

200V 25 HP230V 30 HP460V 50 HP600V 50 HPNEMA 3

Use Suffix -PG at end of part number.For more informationSee Page AEG 9.

For Additional Auxiliaries See Page AEG 24.

CO

NTA

CTO

RS

Page 3: AEG contactors

See AEG Technical Bulletin for more complete technical data and definitions.1) Type LS 7 C: 220/380, 500/600V 3~5/10/12,5 kVar, see page 1/12. 2)as LS37 however PN (AC 3) 500V, 3~: 15 kW. 3) PN (AC 3) 220V/380V/500V/600V, 3~:3 kW/5,5 kW/5,5 kW 4) as LS27, s. S. 1/2 5) as LS7, s. S. 1/2 6) Pin terminal AC 1: 8A; AC 3: 220V/380V, 3~: 0,75 kW/1,1 kW, Ie = 2,8A7) Type LS07: Voltage tolerance 8 ... 1,2 Uc, at 24V-: 1,2 W, with voltage tolerance 0,8 ... 1,7 Uc 8)These are typical values and some variation can be expected9) 220V: 12A 10) 220V: 21A 11) ( )= Values for contactors without economy resistor (reduced power consumption). Closing delay 50 ... 85 ms, opening delay 20 ... 35 ms

AEG 38

TYPE LS CONTACTORS TECHNICAL SPECIFICATIONS

International Ratings

Rated insulation voltage Ui, VDE 0110 IGr C ~V

Mechanical lifespana.c. operated x106 opsd.c. operated x106 opsAC-1 Duty Power rating PN kWRelated current /th = Rated operating current /e AMinimum cable cross sections with full rating mm2

Permissible practical switching frequency ops/hr.Rated operating current at 1000 ops/hr. AAC-3 Duty Motor rating PN kWRated current /e up to 3~440V APermissible switching frequency at PN and continuous operation ops/hr.AC-4 Duty Motor Rating PN kWRated current /e with realistic contact lifespan up to 3~440V APermissible switching frequency ops/hr.Highest permissible loading at 380V 3~ PN/e kW/ACapacitor switching capacity withSingle switching/Parallel operation10) 3~230V kvar

3~400V kvar3~525V kvar3~690V kvar

Permissible D.C. loading,with 3 poles connected in seriesRated current at DC-1 Duty (resistive load) … 24... 220V /e ADC-2...DC-5 Duty (shunt and series wound motorsL/R • 15 ms) … 24... 110V /e A

>… 110... 220V /e APermissible switching frequency (DC-1 ... DC-5) ops/hr.Auxiliary switch Rated insul. voltage Ui VDE 0110 ~V

Continuous current /th AAC-11 Duty Rated current /e up to ~ 220V A(a.c.) at ~ 380V A

at ~ 500V Aat ~ 660V A

DC-11 Duty Rated current /e at … 24V A(d.c.) at … 60V AValues based upon 3 poles at …110V Aconnected in a series at…220V AShort-circuit protection. Highest rated fuse (gL) A

Normal Control Transformer (VA) Optional/StandardOperating coil (Standard) A.C. operatedPower consumption (Voltage tolerance 0.75 … 1, 1 Us)

Closing PAS VA cos

Holding PHS VA cos

DC operatedPower consumption at 1,0 Us Closing PA W(Voltage tolerance 0,85 …1,1 Us)7) Holding PH W

Switching times at 1,0 Us (standard coil)8)A.C. Operated closing delay ms

opening delay msD.C. Operated closing delay ms

opening delay ms

380

4 10 s.p. 1/2166)2,550106)s.p. 1/27,36) (380V)

300-

---

----

10

--50380166)64--2,5(10/86)1,2(5)0,7(3)0,36(1,5)16

160,884,90,45*2,47)2,47)

9 ... 305 ... 25

10 ... 352 ... 8

*SW, Single Winding DC Coil. (**)TW, Two Winding DC Coil

660

10 152 )s.p. 1/2202,55020s.p. 1/29,5

1000s.p. 1/2

3,7250s.p. 1/2

2,5/2,54/44/44/4

20

2045066020106421641,50,516

25/50

550,71100,27* (**)6,5 1306,5 3.2

10 ... 255 ... 16

45 ... 8010 ... 30

660

10 152 )s.p. 1/22545020s.p. 1/212

1000s.p. 1/2

5,3250s.p. 1/2

3/35/56/56/5

25

2565066020106421641,50,516

25/50

550,71100,27* (**)6,512 ) 1306,512) 3.2

10 ... 255 ... 16

45 ... 8010 ... 3012)

660

10 152 )s.p. 1/23245025s.p. 1/216

750s.p. 1/2

7,3250s.p. 1/2

3/35/56/56/5

32

3285066020106421641,50,516

25/50

550,71100,27* (**)6,5 1306,5 3.2

10 ... 255 ... 16

45 ... 8010 ... 30

660

10 -s.p. 1/24065030s.p. 1/223

750s.p. 1/2

9,3250s.p. 1/2

7/713/1317/1317/13

40

40105066020106421641,50,516

50

670,7210,50,27* (**)- 170- 3.5

10 ... 255 ... 16--

660

10 152

s.p. 1/250105040s.p. 1/232

750s.p. 1/2

16250s.p. 1/2

10 /129)16,7/16,79)25 /259)19 /16,79)

50

50165066020106421641,50,516

50

670,7210,50,27* (**)8 1708 3.5

10 ... 255 ... 16

45 ... 8010 ... 30

Type LS07 LS4 LS7 LS17 LS27 LS37

CO

NTA

CTO

RS

Page 4: AEG contactors

AEG 39

TYPE LS CONTACTORS TECHNICAL SPECIFICATIONS

Rated insulation voltage Ui, VDE 0110 IGr C ~V

Mechanical lifespana.c. operated x106 opsd.c. operated x106 opsAC-1 Duty Power rating PN kWRelated current /th = Rated operating current /e AMinimum cable cross sections with full rating mm2

Permissible practical switching frequency ops/hr.Rated operating current at 1000 ops/hr. AAC-3 Duty Motor rating PN kWRated current /e up to 3~440V APermissible switching frequency at PN and continuous operation ops/hr.AC-4 Duty Motor Rating PN kWRated current /e with realistic contact lifespan up to 3~440V APermissible switching frequency ops/hr.Highest permissible loading at 380V 3~ PN/e kW/ACapacitor switching capacity withSingle switching/Parallel operation10) 3~230V kvar

3~400V kvar3~525V kvar3~690V kvar

Permissible D.C. loading,with 3 poles connected in seriesRated current at DC-1 Duty (resistive load) … 24... 220V /e ADC-2...DC-5 Duty (shunt and series wound motorsL/R • 15 ms) … 24... 110V /e A

>… 110... 220V /e APermissible switching frequency (DC-1 ... DC-5) ops/hr.Auxiliary switch Rated insul. voltage Ui VDE 0110 ~V

Continuous current /th AAC-11 Duty Rated current /e up to ~ 220V A(a.c.) at ~ 380V A

at ~ 500V Aat ~ 660V A

DC-11 Duty Rated current /e at … 24V A(d.c.) at … 60V AValues based upon 3 poles at …110V Aconnected in a series at…220V AShort-circuit protection. Highest rated fuse (gL) A

Control Transformer (VA) Optional/StandardOperating coil (Standard) A.C. operatedPower consumption (Voltage tolerance 0.75 … 1, 1 Us)

Closing PAS VA cos

Holding PHS VA cos

DC operated (**)Power consumption at 1,0 Us Closing PA W(Voltage tolerance 0,85 …1,1 Us) Holding PH W

Switching times at 1,0 Us (standard coil)8)A.C. Operated closing delay ms

opening delay msD.C. Operated closing delay ms

opening delay ms

1000

103 s.p. 1/390255080s.p. 1/346276 500s.p. 1/3

23250s.p. 1/3

17/1730/3035/3540/30

90

902550100020108661042120

75/100

2600.53260,23

1704

15 ... 356 ... 20

20 ... 4510 ... 30

(**)TW, Two Winding DC Coil

1000

10 3s.p. 1/3100355090s.p. 1/363378 500s.p. 1/3

32250s.p. 1/3

24/2440/4050/5040/40

100

1003250100020108661042120

75/100

2600,53260,23

1704

15 ... 356 ... 20

20 ... 4510 ... 30

1000

10 3s.p. 1/31103550100s.p. 1/375

500s.p. 1/3

37250s.p. 1/3

24/2440/4050/5040/40

110

1104050

100020108661042120

75/100

2600,53260,23

1704

15 ... 356 ... 20

20 ... 4510 ... 30

1000

10 3s.p. 1/31807050160s.p. 1/3110

500s.p. 1/3

63250s.p. 1/3

35/3560/6080/6660/60

180

1808050100020108661042120

100

4200,53360,23

2804

30 ... 6010 ... 2650 ... 7015 ... 35

1000

10 3s.p. 1/322512050200s.p. 1/3180

500s.p. 1/3

73250s.p. 1/3

58/45100/75130/90100/75

225

22515050100020108661042120

150

7400,42500,26

4305

30 ... 6010 ... 2650 ... 7015 ... 35

1000

10 3s.p. 1/33502x30x450300s.p. 1/3250

500s.p. 1/3

110250s.p. 1/3

87/66150/115190/145150/115

350

35020050100020108661042120

250

9600,26700,38

4006,5

35 ... 6012 ... 2650 ... 7015 ... 35

Type LS47 LS57 LS77 LS87 LS107 LS177 LS247

8) These are typical values, and some variation can be expected11) No potential separationPN - Rated Power

See

AEG

“K” C

onta

ctor

s, fo

r lar

ger S

izes

and

4-P

ole

Con

tact

ors

to 1

,250

Am

p.

1000

10 3s.p. 1/31103550100s.p. 1/387

500s.p. 1/3

46250s.p. 1/3

28/2850/5050/5040/40

110

1104050

100020108661042120

75/100

2600,53260,23

1704

15 ... 356 ... 20

20 ... 4510 ... 30

CO

NTA

CTO

RS

Page 5: AEG contactors

AEG 40

TYPE LS DIMENSIONSAC POWER CONTACTORS

Space Saving Dimensions Type LS7 Contactorwith 3 Auxiliary Contacts

3 Pole Contactor DimensionsOVERALL DIMENSIONS (Inches Approximate)

Dimensions

SIZE

HeightWidthDepth *Depth **Depth#DC (SW Coils)

Depth##

LS07

MINI

1.541.771.65

LS4

00

3.071.772.903.934.43.75

LS7

00

3.071.772.903.934.43.75

LS17

0

3.071.772.903.934.43.75

LS27

1

3.351.774.293.22

LS37

13/4

3.42.0

4.733.625.24.3

LS47

2

4.83.55.0

LS57

21/2

4.83.55.0

LS77LS87

3

4.83.55.0

LS107

31/2

5.914.726.06

LS177

41/2

7.095.316.77

LS247

5

7.95.77.7

LS220/280K

51/2

8.6 7.29.

* Depth with top deck auxiliary set. (Includes DC - TW Coils) **Unit with no auxiliary (.00).# = with top deck aux. (DC Single Winding) ## = No top mount Aux.

MOUNTING DIMENSIONS (Inches Approximate)Mounting Hole

dd1ee1

y,z

1.40.2

w,y

1.380.3

2.360.3

w,y

1.380.3

2.360.3

w,y

1.380.3

2.360.3

w,y

1.380.3

2.95.2

w,y

1.380.3

2.95.22

y,w

3.10.24.3.26

y,w

3.10.24.3.26

y,w

3.10.24.3.26

z,y,z

3.940.395.120.39

x,y,z

4.330.496.300.39

z,y,z

4.70.57.10.4

z,y,z

3.91.57.90.6

CO

NTA

CTO

RS