16
Advisor Advanced Release FW120

Advisor Advanced

Embed Size (px)

DESCRIPTION

Advisor Advanced. Release FW120. Overview. Start up wizard - update Remote user code Zone open too long notification – related to access Keypad E/E counter displayed Inverted Walk Test PIN of the day Service Req message after certain Interval Demo Mode - PowerPoint PPT Presentation

Citation preview

Page 1: Advisor Advanced

Advisor Advanced

Release FW120

Page 2: Advisor Advanced

Overview

1. Start up wizard - update

2. Remote user code

3. Zone open too long notification – related to access

4. Keypad E/E counter displayed

5. Inverted Walk Test

6. PIN of the day

7. Service Req message after certain Interval

8. Demo Mode

9. User code entry without pressing ENTER

10. Option to disable all faults on keypad

11. Walk Test with reporting

12. Walk Test with arming the system

13. Walk Test per zone

14. MMS functionality

Page 3: Advisor Advanced

Start up wizard - update

Installation76%

1. Panel language2. Defaults3. Time & date4. Variant5. Install

Variant PSTN / ISDN / GSM

PIRcam

Page 4: Advisor Advanced

Remote user code

Users - Installer Set PIN code

Remote PIN Set PIN code

Enable login

Page 5: Advisor Advanced

Zone open too long notification – related to access

Zone Others Zone Held Open

Panel Zone Timers Held Open Time

Filters Logical Function Zone / Held open too long

Door Access with Badge, if door is open too long it can activate the output on the reader to beep until the door is closed.

Page 6: Advisor Advanced

Keypad E/E counter displayed

A r e a 1E N T R Y 4 5 s

1 > A r e a 1S e t t i n g 4 5 s

Page 7: Advisor Advanced

Zone Inactive days / Inverted Walk Test

1 > Z o n e 11 0 9

7 >I n a c t i v e D a y s1 1 2

0 > Re s et T i m e r s> > >

Page 8: Advisor Advanced

PIN of the day

Page 9: Advisor Advanced

Service Req message after certain Interval

Inspection date 24/08/2014

Inspection Message Service Required

Page 10: Advisor Advanced

Demo Mode

9 > D e m o m o d e> Y e s <

Active for 15 minDisplays “Demo Mode” on every keypad

Page 11: Advisor Advanced

User code entry without pressing ENTER

8 > E a s y u n s e tY e s

-> Use 1122 to disarm-> cannot be used with Door access 1122 + F

Page 12: Advisor Advanced

Option to disable all faults on keypad

4 > I n d i c a t e f a u l tA l w a y s

Selection:• Always• On Set• Disable all Faults

Page 13: Advisor Advanced

Walk test with reporting

Features

Start Walk test with Reporting

W i t h r e p o r t i n g> Y e s <

The panel supports system walk test whereby all triggered sensors will be reported to the monitoring station, but no siren shall be activated.

• Walktest all zones (only keypad/internal sounder beep)• Walktest all zones with reporting including the keypad/internal sounder beep

To start walk test with reporting : 1>Service menu 2>test menu 5> Walk test menu 1>Start

Then the installer can choose between with or without reporting.

W i t h r e p o r t i n g> N o <

Page 14: Advisor Advanced

Walk test with arming the system

Features

Activate Walk test with arming the system

W a l k t e s t M o d eY e s

The panel supports system walk test whereby the system is armed via the user interface and alarms created by triggering all sensors. All sensor alarms will be reported to the monitoring station, but no siren shall be activated.

To activate Walk Test with arming the system : 1>Service menu 2>test menu 5> Walk test menu 4>Walktest Mode

Walk test scenario is based on a standard use case -> arming the system -> tripping zones -> disarming.

Test ends when the Installer turns off the WT Mode in the menu, or the timer expires. This is to prevent the unwanted remaining in the WT Mode.

Page 15: Advisor Advanced

Walk test per zone

Features

Activate Walk Test per zone

The Walk test per zone is a functionality for the installers who want to verify a single zone instead of having to run a walk test for all zones.

To start Walk Test per zon : 1>Service menu 2>test menu 5> Walk test menu

3>SingleZone WT

The installer can choose between with or without reporting.

Functionality similar to the general walk test option.

W i t h r e p o r t i n g> Y e s <

1 > P a n e l2 I n p u t e x p

I n p u t n u m b e r> 1 <

W a l k t e s ti n p r o g r e s s

1 > Z o n e 1N e e d A c t i v e

W a l k t e s t O KP r e s s E N T E R

Page 16: Advisor Advanced

MMS

Features

Configuration MMS

Possibility to send pictures taken by a PirCam to cell phones using MMS.

Configuration of the MMS functionality:

Central Station settings: MMS Settings (Path Options GSM) :

(Settings MMS Center Belgium)