Advanced wastewater treatment
Gyeongsang National UniversityDepartment of Biological and chemical EngineeringEnvironmental Engineering Lab
Ngoc Thuan Le
2
Need for advanced wastewater treatment
1. Remove organic matter and TSS to meet more stringent discharge and reuse requirements.
2. Remove TSS for more effective disinfection.
3. Remove nutrients contained to limit eutrophication of sensitive water bodies.
4. Remove specific inorganic (e.g., heavy metals) and organic constituents (e.g., MTBE) to meet more stringent discharge and reuse requirements both surface water and land-based effluent dispersal and for indirect potable reuse application.
5. Remove specific inorganic and inorganic constituents for industrial reuse (e.g., cooling water, process water…).
3
Technologies used for advanced treatment
1. Removal of organic and inorganic colloidal and suspended solids (suspended solids, organic matters…), using filtration
• Depth filtration• Surface filtration• Membrane filtratration
4
Depth filtration Surface filtration
5
2. Removal of dissolved organic constituents (total organic carbon, refractory organic, volatile organic compounds)
• Carbon adsorption• Reverse osmosis• Chemical precipitation• Chemical oxidation• Advanced chemical oxidation• Electrodialysis• Distillation
3. Removal of dissolved inorganic constituents (ammonia, nitrate, nitrite, phosphorus, total dissolved solids)
• Chemical precipitation• Ion exchange• Ultrafiltration• Reverse osmosis• Electrodialysis• Distillation
6
4. Removal of biological constituents (bacteria, protozoan cysts and oocysts, viruses)
• Depth filtration• Micro and ultrafiltration• Reverse osmosis• Electrodialysis• Distillation
Because the effectiveness of the unit operations and processes listed is
variable, disinfection of the treated effluent is required for most application
7
Introduction to depth filtration
a. Flow during filtration cycle
b. Flow during backwash cycle
• Grain size is the principal filter medium characteristic that affects the filtration operation
8
Particle removal mechanisms
a. By straining
b. By sedimentation or inertial impaction
c. By interception
d. By adhesion
e. By flocculation
Other phenomena: chemical/physical adsorption or biological growth
9
Selection and design considerations for depth filters
1. Selection and design filter technologies must be based on:• Knowledge of the types of filters that are available• A general understanding of their performance
characteristics• An appreciation of the process variables controlling depth
filtration
2. Design for effluent filtration systems include:• Influent wastewater characteristics• Design and operation of the biological treatment process• Type of filtration technology to be used• Available flow-control options• Type of filter backwashing system• Filter control systems and intrumentation
10
Available filtration technologies
a. Conventional mono-medium downflow filter
b. Conventional dual-medium downflow filter c. Conventional mono-medium
deep-bed downflow filterd. Continuous backwash deep-bed upflow filter
e. Pulse-bed filter f. Traveling-bridge filter
11
Synthetic-medium filter High pressure filter
Slow sand filter
12
Two-stage filtration
A large size sand diameter is used in the first filter to increase the contact time and to minimize clogging
A smaller sand size is used in the second filter to remove residual particles from the first stage filter
13
Effluent filtration with chemical addition
• To achieve specific treatment objectives including removal of specific contaminants
• Phosphorus • Metal ions• Humic substances
• Chemicals commonly used in effluent filtration• Organic polymers (cationic, anionic, or nonionic (no
charge)• Alum and ferric compounds (chloride)
14
Surface filtration
Materials: woven metal fabrics, cloth fabrics of different weaves, and variety of synthetic materials
Surface filters have openings in size range from 10 to 30µm. In membrane filters the pore
size can vary from 0.0001 to 1.0µm
15
Membrane filtration
Materials: different organic or inorganic materials: polypropylene, cellulose acetate, aromatic polyamides, and thin film composite (TFC).
Membrance process
Membrane driving force
Typical separation mechanism
Operating structure (pore size)
Typical operating range, µm
Permeate description
Typical constituents removed
Microfiltration Hydrostatic pressure difference
sieve Macropores (>50nm)
0.08-2.0 Water+dissolved solutes
TSS, turbidity, protozoan, some bacteria and viruses
Ultrafiltration Hydrostatic pressure difference
sieve Mesopores (2-50nm)
0.005-0.2 Water+small molecules
Macromolecules, colloids, most bacteria, some viruses, protein
Nanofiltration Hydrostatic pressure difference
sieve+solution/diffusion+exclusion
Micropores (<2nm)
0.001-0.01 Water+very small molecules, ionic solutes
Small molecules, some harness, viruses
Reverse osmosis
Hydrostatic pressure difference
solution/diffusion+exclusion
Dense (<2nm)
0.0001-0.001
Water+very small molecules, ionic solutes
very small molecules, color hardness, sulfates, nitrate, sodium, other ions
Dialysis Concentration difference
Diffusion Mesopores (2-50nm)
_ Water+very small molecules,
Macromolecules, colloids, most bacteria, some viruses, protein
Electrodialysis Electromotive force ion exchange with selective membranes
Micropores (<2nm)
_ Water, ionic solutes ionized salt ions
16
Reverse osmosis (RO)
• When two solutions having different solute concentrations are separated by a semi permeable membrane, a difference in chemical potential will exist across the membrane
• RO is used for the removal of dissolved constituents from the wastewater remaining after advanced treatment with depth filtration of microfiltration.
a. Osmotic flow
b. Osmotic equilibrium
c. Reverse osmosis
17
Electrodialysis (ED)• In the electrodialysis process, ionic components of a solution are separated
through the use of semipereable ion-selective membrane
• The current required for electrodialysis can be estimated by Faraday’s Laws of electrolysis
Where:
I = current, amp
F = Faraday’s constant
= 96,485amp.s/gram equivalent = 96,485 A.s/eq
n = number of cell in the stack
Ec = current efficiency expressed as a fraction
nEc
FQNI
ŋ
18
Adsorption
• Adsorption is the process of accumulation substances that are in solution on a suitable interface
• Types of adsorbents: activated carbon, synthetic polymeric, and silica-based adsorbents
• Activated carbon: (1) powdered activated carbon (PAC), a diameter of less than 0.074mm (200 sieve), and (2) granular activated carbon (GAC), a diameter greater than 0.1mm (140 sieve)
Parameter UnitType of activated carbon
GAC PAC
Total surface area m2/g 700-1300 800-1800
Bulk density kg/m3 400-500 360-740
Particle density, wetted in water kg/l 1.0-1.5 1.3-1.4
Particle size range mm (µm) 0.1-2.36 (5-50)
Effective size mm 0.6-0.9 na
Uniformity coefficient UC ≤1.9 na
Mean pore radius  16-30 20-40
Iodine number 600-1100 800-1200
Abrasion number minimum 75-85 70-80
Ash % ≤ 8 ≤ 6
Moisture as packed % 2-8 3-10
19
Fundamentals of adsorption
• Absorbent phase concentration data
Where:
qe= absorbent (solids) phase concentration after equilibrium, mg adsorbate/g adsorbent
Co = initial concentration of adsorbate, mg/L
Ce = final equilibrium concentration of adsorbate after absorption has occurred, mg/L
V = volume of liquid in the reactor, L
m = mass of absorbent, g
m
VCCq ee
)( 0
20
Types of activated carbon contactors
21
Gas stripping
• Gas stripping involves the mass transfer of a gas from the liquid phase to the gas phase.
• Considerable attention: remove ammonia, odorous gases and volatile organic compounds (VOCs)
Countercurrent flow Current flowCross flow
Typical water and airflow patterns for gas stripping towers
22
Typical stripping towers for the removal of volatile gases from water
23
ION EXCHANGE
• Ion exchange is a unit process in which ions of a given species are displaced from an insoluble exchange material by ions of a different species in solution.
• Domestic water softening: where sodium ions from a cationic-exchange resin replace the calcium and magnesium ions in the treated water.
• Ion exchange has been used in wastewater application for removal of nitrogen, heavy metals, and total dissolved solids
• Ion-exchange materials:
• Naturally, zeolites (complex of aluminosilicates with sodium)
• Synthetic ion-exchange material: resins or phenolic polymers
1. Strong-acid cation
2. Weak-acid cation
3. Strong-base anion
4. Weak-base anion
5. Heavy-metal selective chelating resins
24
Typical ion-exchange reaction
• For natural zeolite (Z)
Ca2+ Ca2+
ZNa+ + Mg2+ Z Mg2+ + 2Na+
Fe2+ Fe2+
• For synthetic resin (R)
Strong acid cation exchange:
RSO3H + Na+ RSO3Na + H+
2RSO3Na + Ca+2 (RSO3)2Ca + 2Na+
Weak acid cation exchange:
RCOOH + Na+ RCOONa + H+
2RCOONa + Ca+2 (RCOO)2Ca + 2Na+
Strong-base anion exchange:
RR’3NOH + Cl- RR’3NCl + OH-
Weak-base anion exchange:
RNH3OH + Cl- RNH3Cl + OH-
2RNH3Cl + SO42- (RNH3)2SO4 + 2Cl-
25
Application of ion-exchange
• Typical flow diagram for the removal of ammonia by zeolite exchange
26
Application of ion-exchange
• Typical flow diagram for the removal of hardness and for the complete demineralization of water
27
• Oxidizing agents:
ozone (O3),
hydrogen peroxide (H2O2),
permanganate (MnO4),
chloride dioxide (ClO2),
chlorine (Cl2) or (HClO) and
oxygen (O2)
• For reduction of:
BOD,
COD,
ammonia,
nonbiodegradable organic compounds.
Chemical oxidation
28
• Phosphate precipitation with aluminum and iron
Al3+ + HnPO43-n AlPO4 + nH
Fe3+ + HnPO43-n FePO4 + nH
• There are many competing reactions because of the effects of alkalinity, pH, trace elements, and ligands in wastewater
• Dosages are established of bench scale test and occasionally by full scale tests.
29
Ozone/Hydrogen peroxide
H2O2 + 2O3 HO* + HO* +3O2
30
DISTILLATION
• Distillation is a unit operation in which the components of a liquid solution are separated by vaporization and condensation.
31
Thank you for your attention!