5
WINDOW 2 New AXGS18ABTH / APTH / AQTH AXGS24ABTH / APTH / AQTH ADVANCED HYPER TROPICAL SPEC A new model realizes the high performance and energy saving which are more suitable for tropical climate. Super power, Super quiet Super wave 3Super Cooling capacity under 20%UP 60°C ambient High ambient 60°C operation range

ADVANCED HYPER TROPICAL SPEC - O General Air ...mssactrading.com/uploads/3/4/5/5/34555765/... · ADVANCED HYPER TROPICAL SPEC ... AKG9A 2.55-2.50kW / 8,700-8,500BTU/h Dimensions =

Embed Size (px)

Citation preview

Page 1: ADVANCED HYPER TROPICAL SPEC - O General Air ...mssactrading.com/uploads/3/4/5/5/34555765/... · ADVANCED HYPER TROPICAL SPEC ... AKG9A 2.55-2.50kW / 8,700-8,500BTU/h Dimensions =

WINDOW

2

New

AXGS18ABTH / APTH / AQTHAXGS24ABTH / APTH / AQTH

ADVANCED HYPER TROPICAL SPECA new model realizes the high performance and energy saving which are more suitable for tropical climate.

Super power, Super quietSuper wave 3Super

Cooling capacity under20%UP 60°C ambient

High ambient60°C operation range

Page 2: ADVANCED HYPER TROPICAL SPEC - O General Air ...mssactrading.com/uploads/3/4/5/5/34555765/... · ADVANCED HYPER TROPICAL SPEC ... AKG9A 2.55-2.50kW / 8,700-8,500BTU/h Dimensions =

16

WINDOW TYPE

Cooling/Heating capacities are based on the following conditions.CoolingIndoor temperature : 27OC DB/19OC WBOutdoor temperature : 35OC DB/(24OC WB)All air conditioners are single-phase types.Specifications and design subject to change without notice for further improvement. Please check with your dealer.

HeatingIndoor temperature : 20OC DBOutdoor temperature : 7OC DB/6OC WB

SPECIFICATIONSModel No.Capacity ClassInput PowerCapacity Cooling

HeatingCoolingHeatingCoolingHeatingCoolingHeatingCoolingHeating

BTU/h

BTU/hV/ø/Hz

kW

kW

kW/kW

A

Power Consumption

EER

Running Current

Moisture Removal

Room Air Circulation (High)

Pints/hLiter/hC.F.M(m3/h)

H / W / D (mm)kg(lbs)

DimensionsWeightRefrigerant

Item AXGS18ABTH/APTH/AQTH18,000

220-240 V ~ 50 Hz17,400-17,700

-5.10-5.20

-1.78-1.94

-2.87-2.68

-8.4-8.5

-4.30(2.0)

530-571(900-970)

455 × 670 × 71053 (117)

R22

AXGS24ABTH/APTH/AQTH24,000

220-240 V ~ 50 Hz21,700-22,200

-6.35-6.50

-2.26-2.37

-2.81-2.74

-10.5-10.0

-5.50(2.6)

542-565(920-960)

455 × 670 × 71061 (134)

R22

18,000 Btu Model

Current model New modelCurrentmodel

Newmodel 35oCAmbient temperature

Φ395mmDiameter 35mm largeragainst current model

Surface area37% largeragainst current model

4 rows

24,000 Btu Model

EER2.81

EER2.87

Current model New model

35oCAmbient temperature

Large and effective propeller fan

Large heat exchanger  

Prevention of blocking sand Fin pitch: 1.8mm

Heat exchangerWide pitch Corrugate fin

1

Aluminum bracket motor2 Louver design of rear cabinet3

32

1

Adopting super protection against dust and corrosion.

High Reliability

Significantly improved EER by large heat exchanger, hyper tropical compressor, and optimized design..

High energy efficiency

Improvement of compressor motor torque・Improvement of compressor component parts like, vane, roller, shaft etc.・Improvement of lubricity of rotating parts・Improvement of protectors (OLP & thermal protector) workability

Improvement points for running thecompressor up to 60°C ambient:

Advanced technology

Hyper Tropical Compressor4

Temperature rise prevention device (thermal protector) installed

High durability materials

Gas leak protection and low voltage protection OLP (Over Load Protection) device installed

ADVANCED HYPER TROPICAL SPEC

23%up 15%up

Non stop operation up to 60°C ambient

60°C

Powerful cooling capacityunder high ambient

Super power, Super quiet, and Super wave

3 Super

20%up

Page 3: ADVANCED HYPER TROPICAL SPEC - O General Air ...mssactrading.com/uploads/3/4/5/5/34555765/... · ADVANCED HYPER TROPICAL SPEC ... AKG9A 2.55-2.50kW / 8,700-8,500BTU/h Dimensions =

17

Advanced Hyper Tropical Spec

Non stop operation up to 60°C ambient

Non stop operation up to 60°C ambient

60°C60°C

Powerful cooling capacityunder high ambient

Powerful cooling capacityunder high ambient

Super power, Super quiet, and Super wave

Super power, Super quiet, and Super wave

3 Super3 Super

AXGS24ABTH/APTH/AQTH6.35-6.50kW / 21,700-22,200BTU/h

Front Panel Colour White

AXGS18ABTH/APTH/AQTH5.10-5.20kW / 17,400-17,700BTU/h

New model

Current model52°C

60°C New long louverLong louver provides wide airflow

Dimensions = H455 x W670 x D710mm

20%up20%up

20%up

6052Outdoor temperature (°C)

Super Low Discharge Air Outlet temperature

Current model

New model

High

Low

-2°C

Out

let t

empe

ratu

re

Page 4: ADVANCED HYPER TROPICAL SPEC - O General Air ...mssactrading.com/uploads/3/4/5/5/34555765/... · ADVANCED HYPER TROPICAL SPEC ... AKG9A 2.55-2.50kW / 8,700-8,500BTU/h Dimensions =

18

WINDOW TYPE

Dimensions = H428 x W710 x D877 mmFront Panel Colour

Option

White

GoldBrown Wood grain

Dimensions = H349 x W457 x D581mm

Front Panel Colour White

AKG9A 2.55-2.50kW / 8,700-8,500BTU/h

Dimensions = H400 x W660 x D628mm

Front Panel Colour White

AFGA12A 3.40-3.30kW / 11,600-11,300BTU/h

ALG24R(HT) 6.25-6.15kW / 21,300-21,000BTU/h

6.45-6.35kW / 22,000-21,700BTU/h

ALG24A(HT) 6.90-6.75kW / 23,600-23,000BTU/h

ALG27A(HT) 7.90-7.70kW / 27,000-26,300BTU/h

ALGA24A 6.90-6.75kW / 23,600-23,000BTU/h

ALGA27A 7.90-7.70kW / 27,000-26,300BTU/h

Cooling/Heating capacities are based on the following conditions.CoolingIndoor temperature : 27OC DB/19OC WBOutdoor temperature : 35OC DB/(24OC WB)All air conditioners are single-phase types.Specifications and design subject to change without notice for further improvement. Please check with your dealer.

HeatingIndoor temperature : 20OC DBOutdoor temperature : 7OC DB/6OC WB

SPECIFICATIONSModel No.Capacity ClassInput PowerCapacity Cooling

HeatingCoolingHeatingCoolingHeatingCoolingHeatingCoolingHeating

BTU/h

BTU/hV/ø/Hz

kW

kW

kW/kW

A

Power Consumption

EER

Running Current

Moisture Removal

Room Air Circulation (High)

Pints/hLiter/hC.F.M(m3/h)

H / W / D (mm)kg(lbs)

DimensionsWeightRefrigerant

Item

Model No.Capacity ClassInput PowerCapacity Cooling

HeatingCoolingHeatingCoolingHeatingCoolingHeatingCoolingHeating

BTU/h

BTU/hV/ø/Hz

kW

kW

kW/kW

A

Power Consumption

EER

Running Current

Moisture Removal

Room Air Circulation (High)

Pints/hLiter/hC.F.M(m3/h)

H / W / D (mm)kg(lbs)

DimensionsWeightRefrigerant

Item

ALGA24A24,000

240-220/1/5023,600-23,000

-6.90-6.75

-2.95-2.82

-2.38-2.33

-14.7-14.4

-8.00(3.8)590

(1,000)428x710x877

80.0 (176)R22

ALGA27A27,000

240-220/1/5027,000-26,300

-7.90-7.70

-3.15-3.08

-2.51-2.50

-16.0-15.5

-8.50(4.0)610

(1,030)428x710x877

94.0 (207)R22

ALG24A(HT)24,000

240-220/1/5023,600-23,000

-6.90-6.75

-2.85-2.80

-2.42-2.41

-13.2-13.1

-8.00(3.8)590

(1,000)428x710x877

80.0 (176)R22

ALG24R(HT)24,000

240-220/1/5021,300-21,00022,000-21,700

6.25-6.156.45-6.352.55-2.402.28-2.152.45-2.562.83-2.9511.5-11.510.7-10.2

5.10(2.4)565

(960)428x710x877

82.0 (181)R22

ALG27A(HT)27,000

240-220/1/5027,000-26,300

-7.90-7.70

-3.15-3.08

-2.51-2.50

-16.0-15.5

-8.50(4.0)610

(1,030)428x710x877

97.0 (214)R22

AFGA12A12,000

240-220/1/5011,600-11,300

-3.40-3.30

-1.60-1.45

-2.13-2.28

-7.7-7.0

-3.60(1.7)370

(630)400x660x628

47.0 (104)R22

Page 5: ADVANCED HYPER TROPICAL SPEC - O General Air ...mssactrading.com/uploads/3/4/5/5/34555765/... · ADVANCED HYPER TROPICAL SPEC ... AKG9A 2.55-2.50kW / 8,700-8,500BTU/h Dimensions =

19

AXGA18AATB 5.20-5.10kW / 17,800-17,400BTU/h

AXGA24ANTB 6.80-6.65kW / 23,200-22,700BTU/h

Front Panel Colour White

Dimensions = H455 x W670 x D705mm

Dimensions = H455 x W670 x D705mm

Front Panel Colour White

AXG18R 5.20-5.10kW / 17,800-17,400BTU/h5.90-5.70kW / 20,100-19,500BTU/h

AXG18R(HT) 5.20-5.10kW / 17,800-17,400BTU/h

5.90-5.70kW / 20,100-19,500BTU/h

SPECIFICATIONSModel No.Capacity ClassInput PowerCapacity Cooling

HeatingCoolingHeatingCoolingHeatingCoolingHeatingCoolingHeating

BTU/h

BTU/hV/ø/Hz

kW

kW

kW/kW

A

Power Consumption

EER

Running Current

Moisture Removal

Room Air Circulation (High)

Pints/hLiter/hC.F.M(m3/h)

H / W / D (mm)kg(lbs)

DimensionsWeightRefrigerant

Item AXG18R18,000

240-220/1/5017,800-17,40020,100-19,500

5.20-5.105.90-5.702.33-2.232.00-1.902.23-2.292.95-3.0010.8-10.88.9-8.8

6.30(3.0)530

(900)455x670x705

74.0 (163)R22

Model No.Capacity ClassInput PowerCapacity Cooling

HeatingCoolingHeatingCoolingHeatingCoolingHeatingCoolingHeating

BTU/h

BTU/hV/ø/Hz

kW

kW

kW/kW

A

Power Consumption

EER

Running Current

Moisture Removal

Room Air Circulation (High)

Pints/hLiter/hC.F.M(m3/h)

H / W / D (mm)kg(lbs)

DimensionsWeightRefrigerant

Item AXGA18AATB18,000

240-220/1/5017,800-17,400

-5.20-5.10

-2.28-2.18

-2.28-2.34

-10.2-10.4

-5.70(2.7)550

(930)455x670x705

65 (143)R22

AXGA24ANTB24,000

240-220/1/5023,200-22,700

-6.80-6.65

-2.93-2.81

-2.32-2.37

-14.7-14.0

-5.50(2.6)580

(990)455x670x705

71.0 (157)R22

AKG9A9,000

240-220/1/508,700-8,500

-2.55-2.50

-0.95-0.89

-2.68-2.81

-4.0-4.2

-2.30(1.1)215

(365)349x457x581

31.0 (68)R22

AXG18R(HT)18,000

240-220/1/5017,800-17,40020,100-19,500

5.20-5.105.90-5.701.98-1.881.80-1.702.63-2.713.28-3.359.7-9.08.9-8.8

6.30(3.0)530

(900)455x670x705

66.0 (146)R22