20
ADVANCED FLAT CABLE SOLUTIONS

ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

Embed Size (px)

Citation preview

Page 1: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

ADVANCEDFLAT CABLESOLUTIONS

Page 2: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

CONTENTS

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Every effort has been made to ensure the accuracy of the data in this catalog. HCA cannot, however, assume responsibility for any typographical error which may have occurred.

Registered to ISO 9001: 2008

REACHCompliant

Print Version 9/2016

Contents2

Contents FLAT RIBBONFlat Ribbon Cable Overview 03

Microzip Summary Sheet 04

Microzip TPO Solid & Stranded 0.025 inch (0.635 mm) 05

Microzip PVC Solid & Stranded 0.025 inch (0.635 mm) 06

Ribbon Stranded PVC 0.033 inch (0.845 mm) & 0.039 inch (1 mm) 07

PVC Rainbow Ribbon 0.050 inch (1.27 mm) 08

PVC Stranded & Hi-Flex 7 and 19 Stranded 0.050 inch (1.27 mm) 09

TPO Stranded Flat Ribbon 0.050 inch (1.27 mm) 10

Solid Microzip Low Smoke Zero Halogen (LSZH) 0.025 inch (0.635 mm) 11

Stranded Ribbon Low Smoke Zero Halogen (LSZH) 0.050 inch (1.27 mm) 11

PVC Stranded Wide Pitch Ribbon 0.100 inch (2.54 mm), 0.156 Inch (3.96 mm) 12

Shielded and Jacketed Flat Ribbon 13

Manufacturing Overview 14

Flat MQTMQT (Micro-Quick Twist) Ribbon Summary Sheet & Data 15

PVC Stranded Micro Quick-Twist 0.025 inch (0.635 mm) 16

TPO Stranded & Solid Micro Quick-Twist 0.025 inch (0.635 mm) 17

Round to FlatRound to Flat Ribbon 18

Other Hitachi ProductsOther Products offered by Hitachi Cable America 19

Page 3: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

CONTENTS

www.hca.hitachi-cable.com www.hca.hitachi-cable.com Flat Ribbon 3

The process for making great flat cable is simple. Start

with the best materials. Then have the cable built by world

class manufacturing personnel with the best equipment

and tooling available. We run to the tightest tolerances

in the industry with regards to the span and width of our

ribbon cables ensuring consistent compatibility with your

connector.

With Hitachi Cable America you can feel confident specify-

ing our cables to meet your needs for both electrical as

well as physical performance. When faced with design

issues for electrical performance, Hitachi Cable America

has a variety of compounds to meet your specific environ-

mental and electrical needs. Our commitment to excel-

lence also means that we are globally competitive using

state of the art equipment and manufactuing processes for

ultimate efficiency.

The products in this catalog are representative of Hitachi

Cable’s technical design abilities and manufacturing exper-

tise in flat cable.

For Standard & Custom Design Flat Cable: Call Us.........

Hitachi Cable America.

Flat Ribbon Cable

FLAT RIBBON

Page 4: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.comMicrozip Summary4

MICROZIPMicrozip - Flat Ribbon Summary Sheet

PVC UL Styles: 2678 150V 105°C 2651 300V 105°CTPO UL Styles: 20848 150V 105°C

HCA Series No.

Pitch inch

(mm)

Conductor AWG

StrandingInsulation

UL StyleAWM1

Capacitance Impedance Propagation

PagepF/ft.(pF/m)(G-S)

pF/ft.(pF/m)(G-S-G)

(G-S-G)(Ohms)

SE

(G-S)(Ohms)

Diff.

Delayns/ft

(ns/m)

Skewps/ft

(ps/m)(max.)

231130.025

(0.635)

30 7/38 TC

PVC 267815.8

(51.8)23.30 (76.4)

75 1101.62

(5.31)30

(98)6

231290.025

(0.635)

30 1/30 BC

PVC 267814.2

(46.5)25

(82.0)80 130

1.52 (4.98)

36 (118)

6

231960.025

(0.635)

30 7/38 TC

TPO 208488.80

(28.8)15.7

(51.5)82 123

1.44 (4.72)

30 (98)

5

200090.025

(0.635)

31 7/39 TC

TPO 208489.43

(30.9)15.75 (51.6)

90 1271.42

(4.65)40

(131)6

232030.025

(0.635)

30 1/30 SC

TPO 208489.10

(29.8)15.5

(50.8)90 130

1.45 (4.75)

25 (82)

5

231240.033

(0.845)

30 7/38 TC

PVC 267814.4

(47.2)22.50 (73.8)

89.3 136.21.57

(5.15)60

(192)7

231470.039 (1.0)

30 7/38 TC

PVC 267810.03 (32.8)

16.71 (54.8)

140 1001.46

(4.78)25

(82)7

200570.039 (1.0)

28 7/36 TC

PVC 265112.30 (40.3)

22.10 (72.5)

125 901.46

(4.78)50

(164)7

MICROZIPFull extrusion construction providing the tightest pitch tolerancein the industry

Contoured for easy IDC termination

Offered with both stranded and solid conductors

Suitable for SE, MSE, LVD, MLVD, SCSI, Ultra-ATA and otherinternal wiring applications

REACH and RoHS 2 compliant

Note 1: UL 758 Standard for Appliance Wiring Material (AWM)

Note 2: For terms and abbreviations, please reference our Advanced Cabling Solutions catalog and under our Advanced Materials and FAQ sections on our website.

Page 5: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com 5Microzip TPO Solid & Stranded

MICROZIPMicrozip - Flat Ribbon Summary Sheet MICROZIP

PHYSICAL CONSTRUCTION DESCRIPTION These Microzip cables utilize 30 AWG solid or stranded copper extruded with Thermoplastic Olefin (TPO). A polarity stripe is co-extruded into position number one for easy identification and the stripe will not rub off. Standard color is light yellow with a red polarity stripe for 30 AWG and a violet polarity stripe for 32 AWG. Pitch Tolerance ± .0016 inches (± .040 mm).

.027±

.002

.025 ± .0016

Tightest pitch tolerance in the industry

Solid conductor construction for lower cost and higher impedance

Operating temperature: -50 deg C to +105 deg C

APPLICATIONS Ultra ATA 133 and Ultra 160 SCSI, backwards compatible

Internal interconnections for electronic equipment

REACH and RoHS 2 compliant

• 23196 - XX - P - 00YYY • Conductor AWG: 30 7/38 AWG TC • Insulation: TPO• Conductor Resistance ohms/1000 ft (ohms/Km): 106 (347.68)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 15.7(51.5)

• (G-S-G) pF/ft (pF/m): 25 (82)• Impedance (G-S-G) SE - Single End: 82 ohms

• (G-S) Differential: 123 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.44 (4.72)• Maximum Skew ns/ft (ns/m): 0.030 (0.098)

• 23203 - XX - P - 00YYY • Conductor AWG: 30 1/30 AWG SC• Insulation: TPE• Conductor Resistance ohms/1000 ft (ohms/Km): 104 (341.12)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 9.1 (29.84)

• (G-S-G) pF/ft (pF/m): 15.5 (50.84)• Impedance (G-S-G) SE - Single End: 90 ohms

• (G-S) Differential: 130 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.45 (4.75)• Maximum Skew ns/ft (ns/m): 0.025 (0.082)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23196 - 26 - P - 00100 26100 ft

30.48 mWidth: 0.650 in (16.51 mm)

Span: 0.625 in (15.87 mm)

Example 2 23196 - 80 - P - 00100 80100 ft

30.48 mWidth: 2.00 in (50.80 mm)

Span: 1.975 in (50.16 mm)

Part Number Format

23196 - XX - P - 00YYY XX 00YYYWidth: XX * .025 in

Span: XX * .025 in - .025

Building a Part Number

XX= No. of conductors: 26, 34, 40, 50, 64, 68, 80YYY = Put-Up (ft.): 100

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23203- 34 - P - 00100 34100 ft

30.48 mWidth: 0.850 in (21.59 mm)

Span: 0.825 in (20.95 mm)

Example 2 23203- 80 - P - 00200 80200 ft

60.96 mWidth: 2.00 in (50.80 mm)

Span: 1.975 in (50.16 mm)

Part Number Format

23203- XX - P - 00YYY XX 00YYYWidth: XX * .025 in

Span: XX * .025 in - .025

Building a Part Number

XX= No. of conductors: 34, 50, 68, 80YYY = Put-Up (ft.): 100, 400

23196 Pitch: 0.025 in (0.635 mm)

23203 Pitch: 0.025 in (0.635 mm)

Microzip TPO Solid & Stranded 0.025 inch (0.635 mm)

UL Style: 20848* CSA Style: AWM I A/B FT- 1UL Voltage Rating: 150V CSA Voltage Rating: 150VUL Temp: 105°C CSA Temp: 105°C

Other conductor counts and put-ups available upon request. Other variations include 24 AWG and 26 AWG cables.

*Series 23196 and 23203 also offered as UL AWM 150V solutions (20647) upon special request

Page 6: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

PHYSICAL CONSTRUCTION DESCRIPTION This Microzip consists of 30 AWG solid bare or stranded tinned copper. Conductors are then fully extruded with PVC insulation. A red polarity stripe is added to the first conductor for easy identification. Standard color is gray. Pitch Tolerance = ± .0016 inches ( ± .040 mm).

Microzip PVC Solid & Stranded6

MICROZIPMicrozip PVC Solid & Stranded 0.025 inch (0.635 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23129 - 20 - P - 00100 20100 ft

30.48 mWidth: .500 in (12.7 mm)

Span: .475 in (12.1 mm)

Example 2 23129 - 11* - P - 00400 100400 ft

121.92 mWidth: 2.50 in (63.5 mm)

Span: 2.475 in (62.85 mm)

• 23129 - XX - P - 00YYY • Conductor AWG: 30 1/30 AWG BC • Insulation: PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 104 (34.12)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 14.2 (46.57)

• (G-S-G) pF/ft (pF/m): 25 (82)• Impedance (G-S-G) SE - Single End: 80 ohms

• (G-S) Differential: 130 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.52 (4.98) • Maximum Skew ns/ft (ns/m): 0.036 (0.118)

• 23113 - XX - P - 00YYY • Conductor AWG: 30 7/38 AWG TC • Insulation: PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 106 (347.68)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 15.8 (51.82)

• (G-S-G) pF/ft (pF/m): 23.3 (76.424)• Impedance (G-S-G) SE - Single End: 75 ohms

• (G-S) Differential: 110 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.62 (5.31) • Maximum Skew ns/ft (ns/m): 0.030 (0.098)

RED POLARITY STRIPE ON #1 COND EDGE.

.027±

.002

.025 ± .0016

Note: 23113 thickness is 0.025 ± 0.002

Part Number Format

23129 - XX - P - 00YYY XX 00YYYWidth: XX * .025 in

Span: XX * .025 in - .025

Building a Part Number

XX= No. of conductors: 20, 25, 26, 34, 40, 50, 60, 68, 80, 100 (100 = 11*)YYY = Put-Up (ft.): 100, 400

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23113- 10 - P - 00100 10100 ft

30.48 mWidth: 0.250 in (6.35 mm)

Span: 0.225 in (5.72 mm)

Example 2 23113- 11* - P - 00400 100400 ft

121.92 mWidth: 2.50 in (63.5 mm)

Span: 2.475 in (62.85 mm)

Part Number Format

23113- XX - P - 00YYY XX 00YYYWidth: XX * .025 in

Span: XX * .025 in - .025

Building a Part Number

XX= No. of conductors: 20, 25, 26, 34, 40, 50, 60, 68, 80, 100 (100 = 11*)YYY = Put-Up (ft.): 100, 400

23129 Pitch: 0.025 in (0.635 mm)

23113 Pitch: 0.025 in (0.635 mm)

RIBBON

Also available: 20009/xx for 31 AWG stranded SPC, 20021/xx for 32 AWG stranded SPC, and 20034/xx for 32 AWG solid SPC. Other conductor counts and put-ups available upon request.

UL Style: 2678 CSA Style: AWM I A/B FT- 1UL Voltage Rating: 150V CSA Voltage Rating: 150VUL Temp: 105°C CSA Temp: 105°C

Tightest pitch tolerance in the industry

Solid conductor construction for lower cost and higher impedance

Operating temperature: -20 deg C to +105 deg C

APPLICATIONS Ultra ATA 133 and Ultra 160 SCSI, backwards compatible

Internal interconnections for electronic equipment

REACH and RoHS 2 compliant

Page 7: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Easy IDC termination

Pitch tolerance ± .002 inches (± 0.050 mm)

0.0333” (.845 mm) and 1mm pitch for hard drives

Solid electrical performance in a low cost design

Manufactured with 30 and 28 AWG stranded tinned copper

APPLICATIONS Disk drives

REACH and RoHS 2 compliant

7

MICROZIPMicrozip PVC Solid & Stranded 0.025 inch (0.635 mm)

Ribbon Stranded PVC

PHYSICAL CONSTRUCTION DESCRIPTION HCA’s series 23124, 23147 and 20057 are constructed with stranded tinned copper. Conductors are fully extruded with flexible gray PVC compound.

.027±

.002P

RIBBONRibbon Stranded PVC 0.033 inch (0.845 mm) & 0.039 inch (1 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23147- 44 - P - 00100 44100 ft

30.48 mWidth: 1.100 in (27.94 mm)Span: 1.075 in (27.30 mm)

Example 2 23147 - 50 - P - 00100 50100 ft

30.48 mWidth: 1.250 in (31.75 mm)Span: 1.225 in (31.11 mm)

• 23147 - XX - P - 00YYY • Conductor AWG: 30 7/38 AWG TC • Insulation: PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 106 (347.68)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 10.03 (32.89)

• (G-S-G) pF/ft (pF/m): 16.71 (54.8)• Impedance (G-S-G) SE - Single End: 100 ohms

• (G-S) Differential: 140 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.46 (4.78)

Maximum Skew ns/ft (ns/m): 0.025 (0.082)

• 20057 - XX - P - 00YYY • Conductor AWG: 28 7/36 AWG TC • Insulation: PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.40)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 12.3 (40.3)

• (G-S-G) pF/ft (pF/m): 22.1 (72.4)• Impedance (G-S-G) SE - Single End: 90 ohms

• (G-S) Differential: 125 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.46 (4.78)

Maximum Skew ns/ft (ns/m): 0.050 (0.164)

Part Number Format

23147 - XX - P - 00YYY XX 00YYYWidth: XX * .039 in

Span: XX* .039 in - .039

Building a Part Number

XX= No. of conductors: 10, 20, 34, 40, 50YYY = Put-Up (ft.): 100

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 20057- 10 - P - 00100 10100 ft

30.48 mWidth: 0.250 in (6.30 mm)Span: 0.225 in (5.72 mm)

Example 2 20057- 50 - P - 00100 50100 ft

30.48 mWidth: 2.00 in (50.80 mm)Span: 1.975 in (50.16 mm)

Part Number Format

20057 - XX - P - 00YYY XX 00YYYWidth: XX * .039 in

Span: XX* .039 in - .039

Building a Part Number

XX= No. of conductors: 96, other conductor counts available upon requestYYY = Put-Up (ft.): 100

23147 Pitch: 0.039 in (1.0 mm)

20057 Pitch: 0.039 in (1.0 mm)

• 23124 - XX - P - 00YYY • Conductor AWG: 30 7/38 AWG TC • Insulation: PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 106 (347.68)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 14.4 (47.23)

• (G-S-G) pF/ft (pF/m): 22.5 (73.8)• Impedance (G-S-G) SE - Single End: 89.3 ohms

• (G-S) Differential: 136.2 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.57 (5.14)

Maximum Skew ns/ft (ns/m): 0.06 (0.19)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23124- 96 - P - 00100 96100 ft

30.48 mWidth: 2.400 in (60.96 mm)Span: 2.375 in (60.32 mm)

Part Number Format

23124 - XX - P - 00YYY XX 00YYYWidth: XX * .033 in

Span: XX* .033 in - .033

Building a Part Number

XX= No. of conductors: 96, other conductor counts available upon requestYYY = Put-Up (ft.): 100

23124 Pitch: 0.033 in (0.845 mm)

Other conductor counts and put-ups available upon request. All data is for reference only and is subject to change.

UL Style: 2678 / 2651 CSA Style: AWM I A/B FT- 1UL Temp: 105°C CSA Voltage Rating: 150V/300VUL2678: 150V, UL2651: 300V CSA Temp: 105°C

Page 8: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Pitch tolerance ± 0.003 inches (± .0762mm)

Continuous bonded. Individually color coded conductors for easy identification in discrete wire termination

Fully extruded construction. No lamination tapes to impede termination

Well centered conductors ensure reliable IDC termination

APPLICATIONS Internal wiring of electronic equipment

.036+.002- .001

.050 ± .003

PHYSICAL CONSTRUCTION DESCRIPTION This 0.050 inch (1.27 mm) flat Rainbow Ribbon cable is constructed with individually extruded 28 AWG (7/36 stranded TC). All primaries are then pulled parallel and bonded intermittently (BI). Color sequence: ten unique colors: Brown, Red, Orange, Yellow, Green, Blue, Violet, Gray, White, Black and repeat.

Pitch tolerance ± 0.003 inches (± .0762mm)

PVC insulated conductors

Intermittently heat bonded increases flexibility

Bonded section repeats every 6.25 inches (158.75 mm)

IDC termination section 1.25 inches (31.75 inches) wide

APPLICATIONS Internal wiring of appliances, electronic computers or business equipment

Rainbow Ribbon8

RAINBOW PVCRainbow Ribbon 0.050 inch (1.27 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23104 - 10 - P - 00200 10200 ft

60.96 mWidth: 0.250 in (6.30 mm)Span: 0.225 in (5.72 mm)

Example 2 23104 - 60 - P - 00200 60200 ft

60.96 mWidth: 1.500 in (38.10 mm)Span: 1.475 in (37.46 mm)

• 23104 - XX - P - 00YYY• Conductor AWG: 28 7/36 AWG TC • Insulation: PVC- BI• Conductor Resistance ohms/1000 ft (ohms/Km): 69.5 (227.96)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 10.9 (35.752)

• (G-S-G) pF/ft (pF/m): 17.3 (56.744)• Impedance (G-S-G) SE - Single End: 90 ohms

• (G-S) Differential: 126 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.55 (5.08)

Maximum Skew ns/ft (ns/m): 0.050 (0.164)

Part Number Format

23104- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

23104 Pitch: 0.050 in (1.27 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23026- 09 - P - 00100 9100 ft

30.48 mWidth: 0.225 in (5.71 mm)Span: 0.200 in (5.08 mm)

Example 2 23026- 64 - P - 00100 64100 ft

30.48 mWidth: 1.60 in (40.64 mm)Span: 1.575 in (40.00 mm)

• 23026 - XX - P - 00YYY• Conductor AWG: 28 7/36 AWG TC • Insulation: SR-PVC/PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 7.48 (24.53)

• (G-S-G) pF/ft (pF/m): 14.05 (46.08)• Impedance (G-S-G) SE - Single End: 98 ohms

• (G-S) Differential: 135 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.45 (4.75)

Maximum Skew ns/ft (ns/m): 0.086 (0.28)

Part Number Format

23026- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

23026 Pitch: 0.050 in (1.27 mm)

XX= No. of conductors: 10, 14, 16, 20, 26, 30, 34, 40, 50, 60YYY = Put-Up (ft.): 200

XX= No. of conductors: 09, 10, 14, 15, 16, 20, 24, 25, 26, 34, 37, 40, 50, 60, 64YYY = Put-Up (ft.): 100

Other conductor counts and put-ups available upon request. Available in 26 AWG (20002) and 30 AWG (20042).

Other conductor counts and put-ups available upon request. Other variations include 30 AWG and 26 AWG (20074) cables. PVC - BI: Intermittently Heat bonded PVC insulated wires with no lamination tapes. Spacing between bonded section is 6.25 inches (158.75 mm)

UL Style: 20012UL Voltage Rating: 150V

UL Temp: 80°C

UL Style: 20932 CSA listing: AWM I A/B FT-1UL Voltage Rating: 300V CSA Voltage Rating: 300VUL Temp: 105°C CSA Temp: 105°C

.035±

.005

.050 ± .003

Page 9: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com PVC Stranded and High-Flex 9

RAINBOW PVCRainbow Ribbon 0.050 inch (1.27 mm)

PHYSICAL CONSTRUCTION DESCRIPTION 23100 is extruded gray PVC flat planar cable using 28 AWG (7/36) tinned copper, on 0.050 inch (1.27mm) centers. 23108 is Hi-Flex extruded gray PVC flat planar cable using 28 AWG stranded (19/40) tinned copper, 0.050 inch (1.27 mm) centers. Conductor number one is marked with a red polarity stripe.

.035±

.002

.050 ± .002

PVC Stranded & Hi-Flex 7 and 19 Strand 0.050 inch (1.27 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23100 - 06 - P - 00100 10100 ft

30.48 mWidth: 0.250 in (6.30 mm)Span: 0.225 in (5.72 mm)

Example 2 23100 - 64 - P - 00100 60100 ft

30.48 mWidth: 1.500 in (38.10 mm)Span: 1.475 in (37.46 mm)

• 23100 - XX - P - 00YYY• Conductor AWG: 28 7/36 AWG TC • Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 8.90 (29.19)

• (G-S-G) pF/ft (pF/m): 14.0 (45.92)• Impedance (G-S-G) SE - Single End: 105 ohms

• (G-S) Differential: 145 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.40 (4.59)

Maximum Skew ns/ft (ns/m): 0.035 (0.114)Part Number

Format23100- XX - P - 00YYY XX 00YYY

Width: XX * .050 inSpan: XX* .050 in - .050

Building a Part Number

23100 Standard Flex Pitch: 0.050 in (1.27 mm)

XX= No. of conductors: 6, 9, 10, 12, 14, 15, 16, 20, 24, 25, 26, 30, 34, 36, 37, 40, 50, 60, 64 YYY = Put-Up (ft.): 100

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23108- 10 - P - 00100 10100 ft

30.48 mWidth: 0.250 in (6.30 mm)Span: 0.225 in (5.72 mm)

Example 2 23108- 50 - P - 00100 50100 ft

30.48 mWidth: 1.250 in (31.75 mm)Span: 1.225 in (31.11 mm)

• 23108 - XX - P - 00YYY• Conductor AWG: 28 19/40 AWG TC • Conductor Resistance ohms/1000 ft (ohms/Km): 63.1 (206.96)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 8.36 (27.42)

• (G-S-G) pF/ft (pF/m): 15.75 (51.66)• Impedance (G-S-G) SE - Single End: 101 ohms

• (G-S) Differential: 142 ohms• Propagation Delay Nanoseconds/ft (ns/m): 2.90 (9.51)

Maximum Skew ns/ft (ns/m): 0.050 (0.164)Part Number

Format23108- XX - P - 00YYY XX 00YYY

Width: XX * .050 inSpan: XX* .050 in - .050

Building a Part Number

23108 Hi-Flex Pitch: 0.050 in (1.27 mm)

XX= No. of conductors: 10, 20, 26, 34, 40, 50YYY = Put-Up (ft.): 100

Other conductor counts and put-ups available upon request. Available in tinned overcoat copper (20069), 30 AWG Solid TC (20052), 28 solid TC (23197), and 26 AWG stranded TC (23043). Other Putup lengths possible. Contact factory for details.

UL Style: 2651 CSA listing: AWM I A/B FT-1UL Voltage Rating: 300V CSA Voltage Rating: 300VUL Temp: 105°C CSA Temp: 105°C

Symmetrical profile offers easy conductor separation (zip) without cable damage and allows reverse termination

0.050 inch (1.27mm) pitch for use with today’s low cost IDC connectors

Design for use with high speed automated termination equipment

APPLICATIONS Internal wiring of electronic equipment

Page 10: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

TPO insulated for superior electrical performance, i.e. high impedance andlow capacitance

Outstanding low temperature characteristics

Improved heat aging over conventional PVC

Available in other wire sizes

APPLICATIONS Ideal for higher controlled impedance signals

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Other conductor counts and put-ups available upon request. Other variations include 24 AWG and 26 AWG cables.

TPO Stranded Flat Ribbon10

TPO LSZHTPO Stranded Flat Ribbon 0.050 inch (1.27 mm)

.035±

.002

.050 ± .002

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23065- 20 - P - 00100 20100 ft

30.48 mWidth: 0.500 in (12.70 mm)Span: 0.475 in (12.06 mm)

Example 2 23065- 50 - P - 00100 50100 ft

30.48 mWidth: 1.250 in (31.75 mm)Span: 1.225 in (31.11 mm)

• 23065 - XX - P - 00YYY• Conductor AWG: 28 7/36 AWG TC• Insulation: TPO • Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 5.60 (18.3)

• (G-S-G) pF/ft (pF/m): 9.70 (31.81)• Impedance (G-S-G) SE - Single End: 106 ohms

• (G-S) Differential: 145 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.26 (4.13)

Maximum Skew ns/ft (ns/m): 0.020 (0.065)

Part Number Format

23065- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

23065 Pitch: 0.050 in (1.27 mm)

XX= No. of conductors: 20, 34, 40, 50YYY = Put-Up (ft.): 100

UL Style: 20346 CSA listing: AWM I A/B FT-1UL Voltage Rating: 300V CSA Voltage Rating: 300VUL Temp: 105°C CSA Temp: 105°C

PHYSICAL CONSTRUCTION DESCRIPTION This 0.050 inch (1.27mm) flat ribbon cable is constructed with 28 AWG stranded tinned copper then fully extruded with a Thermoplastic Olefin (TPO). A red stripe is applied for polarity identification.

Page 11: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com Solid & Stranded Microzip Low Smoke Zero Halogen 11

TPO LSZHTPO Stranded Flat Ribbon 0.050 inch (1.27 mm)

Pitch 025 (0.635 mm) ± 0.0016”.

Low smoke zero halogen polyolefin thermoplastic

ECO friendly

APPLICATIONS Ultra ATA 33, 66, 100 and 133. Internal wiring of electronicequipment

REACH and RoHS 2 compliant.027

±.002

.025 ± .0016

.035±

.002

.050 ± .002

PHYSICAL CONSTRUCTION DESCRIPTION This Microzip consists of 30 AWG solid bare copper. Each leg of copper is pulled in parallel and fully extruded. A polarity stripe is co-extruded into position number one for easy identification. Color is green with black polarity.

Solid Microzip Low Smoke Zero Halogen (LSZH) 0.025 inch (0.635 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 20103 - 68 - P - 00400 68 400 ft121.92 m

Width: 1.700 in (43.18 mm)Span" 1.675 in (42.54 mm)

Example 2 20103 - 80 - P - 00400 60 400 ft121.92 m

Width: 1.500 in (38.10 mm)Span: 1.475 in (37.46 mm)

• 20103 - XX - P - 00YYY • Conductor AWG: 30 1/30 AWG BC • Insulation: LSZH• Conductor Resistance ohms/1000 ft (ohms/Km): 104 (341.12)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 12.5 (41.01)

• (G-S-G) pF/ft (pF/m): 22.0 (72.17)• Impedance (G-S-G) SE - Single End: 80 ohms

• (G-S) Differential: 130 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.60 (5.25)

Maximum Skew ns/ft (ns/m): 0.060 (0.196)

Part Number Format

20103- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

20103 Pitch: 0.025 in (0.635 mm)

XX= No. of conductors: other conductor counts available upon requestYYY = Put-Up (ft.): 400

Stranded Ribbon Low Smoke Zero Halogen (LSZH) 0.050 inch (1.27 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 20097- 06 - P - 00100 6100 ft

30.48 mWidth: 0.150 in (3.81 mm)Span: 0.125 in (3.17 mm)

Example 2 20097- 64 - P - 00100 64100 ft

30.48 mWidth: 1.60 in (40.64 mm)Span: 1.575 in (40.00 mm)

• 20097 - XX - P - 00YYY• Conductor AWG: 28 7/36 AWG TC • Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 12.5 (41.01)

• (G-S-G) pF/ft (pF/m): 7.5 (24.60)• Impedance (G-S-G) SE - Single End: 95 ohms

• (G-S) Differential: 135 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.60 (5.25)

Maximum Skew ns/ft (ns/m): 0.060 (0.196) Part Number Format

20097- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

20097 Pitch: 0.050 in (1.27 mm)

XX= No. of conductors: 06, 09, 10, 12, 14, 15, 16, 20, 24, 25, 26, 30, 34, 36, 37, 40, 50, 60, 64YYY = Put-Up (ft.): 100

Other conductor counts and put-ups available upon request. Available in tinned overcoat copper (20069), 30 AWG Solid TC (20052), 28 solid TC (23197), and 26 AWG stranded TC (23043). Other Put-up lengths possible. Contact factory for details.

Other conductor counts and put-ups available upon request. All data is for reference only and is subject to change.

UL Style: 20930 (Pending) CSA Style: AWM I A/B FT- 1UL Voltage Rating: 30V CSA Voltage Rating: 30VUL Temp: 105°C CSA Temp: 105°C

UL Style: 20930 (Pending) CSA listing: AWM I A/B FT-1UL Voltage Rating: 30V CSA Voltage Rating: 30VUL Temp: 105°C CSA Temp: 105°C

Symmetrical profile offers easy conductor separation without cable damageand allows reverse termination

0.050 inch (1.27mm) pitch for use with today’s low cost IDC connectors

Design for use with high speed automated termination equipment

APPLICATIONS Internal wiring of electronic equipment

Page 12: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

PVC Stranded Wide Pitch Ribbon12

WIDE PITCHPVC Stranded Wide Pitch Ribbon

T

.100 ± .003

POLARITY STRIPE ON #1 COND EDGE.

.012 ± .003

PHYSICAL CONSTRUCTION DESCRIPTION Flat planar cable using 22, 24, or 26 AWG stranded tinned copper, extruded in PVC on 0.100 inch (2.54 mm) centers. Conductor number one is marked with a polarity stripe. Standard cable color is gray.

Part Number ConductorConductor Resistance

Ohms/1000 Ft Nominal @ 20 deg C

(Ohms/Km)

Capacitance pF/ft (pF/m)

Impedance (Ohms) G-S-G

Pitch Inch mm

Width “W” Span “S”

23232-XX-P-00YYY26 AWG

(7/34) TC42.5 (139.4) 12 (39.36) 150

0.100 in Width: 0.650 in (16.51 mm)2.54 mm Span: 0.625 in (15.87 mm)

23224-XX-P-00YYY24 AWG

(7/32) TC25.7 (84.2) 13 (42.64) 130

0.100 in Width: 0.600 in (15.24 mm)2.54 mm Span: 0.575 in (12.60 mm)

23225-XX-P-00YYY22 AWG

(7/30) TC15.0 (49.2) 12 (39.36) 115

0.100 in Width: 0.550 in (13.97 mm)2.54 mm Span: 0.525 in (13.33 mm)

20008-XX-P-00YYY22 AWG

(7/30) TC16.8 (55.1) 10 (32.8) 160

0.156 in Width: 0.550 in (13.97 mm)3.96 mm Span: 0.525 in (13.33 mm)

23261-XX-P-00YYY20 AWG

(7/28) TC10.3 (33.78) 11 (36.08) 140

0.156 in Width: 0.500 in (12.70 mm)3.96 mm Span: 0.475 in (12.06 mm)

23236-XX-P-00YYY18 AWG

(19/30) TC6.07 (19.9) 10 (32.8) 125

0.156 in Width: 0.450 in (11.43 mm)3.96 mm Span: 0.425 in (10.79 mm)

20028-XX-P-00YYY26 AWG

(7/34) TTC43.1 (141.3) 12 (39.36) 150

0.100 in Width: 0.650 in (16.51 mm)2.54 mm Span: 0.625 in (15.87 mm)

20027-XX-P-00YYY24 AWG

(7/32) TTC26.5 (86.92) 13 (42.64) 130

0.100 in Width: 0.600 in (15.24 mm)2.54 mm Span: 0.575 in (12.60 mm)

20026-XX-P-00YYY22 AWG

(7/30) TTC15.0 (49.2) 12 (39.36) 115

0.100 in Width: 0.550 in (13.97 mm)2.54 mm Span: 0.525 in (13.33 mm)

20029-XX-P-00YYY22 AWG

(7/30) TTC16.8 (55.1) 10 (32.8) 160

0.156 in Width: 0.550 in (13.97 mm)3.96 mm Span: 0.525 in (13.33 mm)

23198-XX-P-00YYY20 AWG

(7/28) TTC10.3 (33.78) 12.6 (41.32) 127

0.156 in Width: 0.500 in (12.70 mm)3.96 mm Span: 0.475 in (12.06 mm)

20017-XX-P-00YYY18 AWG

(19/30) TTC6.07 (19.9) 10 (32.8) 125

0.156 in Width: 0.450 in (11.43 mm)3.96 mm Span: 0.425 in (10.79 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Part Number Format

Part #- XX - P - 00YYY XX OOYYYWidth: XX * .100 in

Span: XX* .100 in - .100

Building a Part Number Pitch: 0.100in (2.54mm)

23232, 23244, 23245, 20008, 23261, 23236, 20028, 20027, 20026, 20029, 23198, 20017Insulation: PVCPropagation Delay Nanoseconds/ft (ns/m): 1.35 (4.42)

23232 Conductor (XX) Count Options: 04, 06, 08, 10, 12, 14, 16 23244 Conductor (XX) Count Options: 05, 06, 07, 08, 10, 2823245 Conductor (XX) Count Options: 03, 04, 09, 1020008 Conductor (XX) Count Options: 03, 04, 09, 1023261 Conductor (XX) Count Options: 04, 05, 1023236 Conductor (XX) Count Options: 02, 03, 04, 06, 07, 08, 15, 24 20028 Conductor (XX) Count Options: 03, 04, 05, 06, 10, 11, 12, 14, 16, 24 20027 Conductor (XX) Count Options: 10, 1220026 Conductor (XX) Count Options: 03, 04, 07, 10, 14, 2820029 Conductor (XX) Count Options: 06, 08, 10, 16, 20, 2423198 Conductor (XX) Count Options: 10, 12, 15, 18, 2420017 Conductor (XX) Count Options: 07, 10, 24

UL Style: 2651 CSA listing: AWM I A/B FT-1UL Voltage Rating: 300V CSA Voltage Rating: 300VUL Temp: 105°C CSA Temp: 105°C

Rounded edge constructionDual zip construction between each webMultiple gauges available to meet your specific needsAlternate copper coatings and configurations availableAPPLICATIONS Internal wiring of electronic equipment 0.156 inch (3.96mm)Multiple wire sizes availableWell centered conductors ensure reliable IDC terminationAPPLICATIONS Internal wiring of electronic equipment

SHIELDED

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Part Number Format

Part #- XX - P - 00YYY XX OOYYYWidth: XX * .156 in

Span: XX* .156 in - .156

Building a Part Number Pitch: 0.156in (3.96mm)

XX= No. of conductors (see table at right for conductor count availability)YYY = Put-Up (ft.): 100, 500TC= Tinned TTC = Tinned Topcoated

0.100 inch (2.54 mm)0.156 Inch (3.96 mm)

Page 13: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

13

WIDE PITCH

Shielded and Jacketed Flat Ribbon

SHIELDEDShielded and Jacketed Flat Ribbon

Shielded flat ribbon cable for EMI/RFI/ESD considerations

Two drain wires for insured grounding

Cable core features our popular 0.050 inch (1.27mm) pitch ribbon cable forease of termination with most IDC connectors

Choose from a wide selection of conductor counts

APPLICATIONS Ideal for environments where EMI/RFI/ESD may be an issue

PHYSICAL CONSTRUCTION DESCRIPTION Using HCA 23100 (page 9) for the core of this shielded cable, two 28 AWG (7/36 TC) drain wires are pulled in separate to ensure contact with the Aluminum/Polyester tape (AL side in). The core is jacketed in Black PVC*.

.035±

.002

.115±

.015

.050 ± .002

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23012- 14 - P - 00100 14100 ft

30.48 mWidth: 0.350 in (8.89 mm)Span: 0.325 in (8.25 mm)

Example 2 23012- 34 - P - 00100 34100 ft

30.48 mWidth: 0.850 in (21.59 mm)Span: 0.825 in (20.95 mm)

• 23012 - XX - P - 00YYY• Conductor AWG: 28 7/36 AWG TC• Insulation: PVC• Shield Construction Drain / Tape Shield: AL/PET• Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 20 (58) • Impedance (G-S-G): 70 ohms

Part Number Format

23012- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

23102

XX= No. of conductors: 14, 15, 16, 20, 25, 26, 34YYY = Put-Up (ft.): 660

*Standard jacket color is Black. Other colors are available upon request. Other conductor counts and put-ups available upon request.

UL Listing: 2912 UL Temp: 105°CUL Voltage Rating: 150V

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

0.100 inch (2.54 mm)0.156 Inch (3.96 mm)

Page 14: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Flat ribbon cable requires more than sophisticated tooling, high qual-ity plastics, and the latest extrusion equipment. It also requires a variety of measurement devices to help us verify tightly-controlled ribbon dimensions and plastic thicknesses to meet the UL voltage requirements. Non-contact laser measurement of ribbon dimensions provides production operators and feedback systems with results hundreds of times per second. Also, as part of in-line testing proce-dure, we continuously apply high voltage to the cable during manu-facturing. This process allows us to better monitor the quality of the cable produced and ensure proper quality control.

Quality personnel look at the structure of the ribbon cable’s plastic web to ensure that wires can be separated by the customer. Our visual inspection system can detail the structure of the entire cross-section of a wide ribbon cable, allowing inspectors to see the product at great magnification where necessary.

TheProcess

With trained operators, the right equipment and sophisticated quality support, you can rest assured that Hitachi Cable will meet and exceed your flat cable needs.

TheHitachi Difference

Flat Cable Manufacturing Process14

PROCESSFlat Cable Manufacturing Process MQT

Page 15: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com MQT Summary 15

PROCESSFlat Cable Manufacturing Process

Heat bonded construction providing tight pitch control

Contoured flat sections for ease of IDC termination

Non-laminated versions allow for bundling to reduce resistance to air flow

Stranded construction for greater flexibility and flex life

Solid copper constructions also available

Suitable for SE, MSE, LVD and MLVD applications

Ask about our products SCSI NEXZ designed for Ultra 320

REACH and RoHS 2 compliant

HCA Short Description

HCA Series No.

Bond Length

inch (mm)

Conductor AWG

Stranding Coating

Insulation

Span of Flat to

Flat Inch (mm)

Capacitance Impedance Propagation Delay

PageGround-Signal

(G-S)pF/ft (pF/m)

Diff.

Ground-Signal(G-S-G)

pF/ft (pF/m)SE

(G-S-G)(Ohms)

SE - Single End

(G-S)(Ohms)

Diff.

Nanoseconds/ft(ns/m)

Max. Skewns/ft (ns/m)

MQT23195 1.57 (40) 30

7/38 TC

PVC9.84 (250) 14.9 (48.88) 18.9 (62.00) 91 117 1.56 (5.12) 35 (114.8) 16

20050 1.57 (40) 4.92 (125) 14.6 (47.89) 19.2 (62.99) 82 113 1.52 (4.99) 35 (114.8) 16

TPO MQT20062 1.57 (10) 30

7/38 TC

TPO9.84 (250) 10.3 (33.79) 13.3 (43.63) 95 120 1.56 (5.12) 35 (114.8) 17

20051 1.57 (40) 4.92 (125) 10.8 (35.43) 14.8 (48.55) 90 115 1.56 (5.12) 35 (114.8) 17

TPO DLMQT

20089 1.57 (40) 30 7/38 TC

TPO9.84 (250) 10.4 (34.12) 14.0 (45.93) 88 117 1.56 (5.12) 35 (114.8) 17

20096 1.98 (50) 5.24 (133) 11.0 (34.12) 15.0 (49.21) 86 115 1.56 (5.12) 35 (114.8) 17

Note 1: MQT is Micro Quick-Twist cable that is a twisted pair cable with bonded sections on 0.025 inch (0.635 mm) pitch with no lamination tape. Note 2: A span is the combination of one bonded section and one twisted section.Note 3: HCA offers custom span cables with either 40 or 50mm bonded sections with up to a maximum of 7 different lengths of twisted pair sections before the pattern repeats.Note 4: Other fixed spans available.

PVC UL/cUL Listing: 20528 TPO UL/cUL Listing: 21057PVC UL/cUL Voltage: 150V TPO UL/cUL Voltage: 150VPVC UL/cUL Temp: 105°C TPO UL/cUL Temp: 90°CPVC UL/cUL Flame Rating: VW-1 TPO UL/cUL Flame Rating: Call

MQTMQT Summary Sheet

Page 16: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Pitch tolerance ± .002 inches (± .050 mm)

Reduced noise and crosstalk

Ideal for IDC termination with high-density connectors

Great alternative to fully extruded FEP and TPO ribbon cable

APPLICATIONS SCSI, Fast-XX, SPI-2 and SPI-3

Micro Quick-Twist PVC Stranded16

MQT MQTMicro Quick-Twist PVC Stranded 0.025 inch (0.635 mm)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23195- 26 - P - 00200 26 200 ft60.96 m

Width: 0.650 in (16.51 mm) Span: 0.625 in (15.87 mm)

Example 2 23195 - 11* - P - 00200 100 200 ft60.96 m

Width: 2.50 in (63.5 mm)Span: 2.475 in (62.85 mm)

• 23195 - XX - P - 00YYY • Conductor AWG: 30 7/38 AWG TC • Insulation: PVC-NL• Conductor Resistance ohms/1000 ft (ohms/Km): 106 (347.68)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 14.9 (48.87)

• (G-S-G) pF/ft (pF/m): 18.9 (91.992)• Impedance (G-S-G) SE - Single End: 91 ohms

• (G-S) Differential: 117 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.56 (5.116)

Maximum Skew ns/ft (ns/m): 0.035 (0.114)

Part Number Format

23195- XX - P - 00YYY XX 00YYYWidth: XX * .025 in

Span: XX * .025 in - .025

Building a Part Number

XX= No. of conductors: 26, 34, 50, 68, 80, 100 (100 = 11*)YYY = Put-Up (ft.): 200

23195 Pitch: 0.025 in (0.635 mm)

• 20050- 68 - P - 00YYY • Conductor AWG: 30 7/38 AWG TC • Insulation: PVC-NL• Conductor Resistance ohms/1000 ft (ohms/Km): 106 (347.6)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 14.6 (47.88)

• (G-S-G) pF/ft (pF/m): 19.2 (62.97)• Impedance (G-S-G) SE - Single End: 82 ohms

• (G-S) Differential: 113 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.52 (4.98)

Maximum Skew ns/ft (ns/m): 0.035 (0.114)

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 20050- 68 - P - 00200 68 200ft60.96 m

Width: 1.700 in (43.18 mm)Span" 1.675 in (42.54 mm)

Part Number Format

20050- XX - P - 00YYY XX 00YYYWidth: XX * .025 in

Span: XX * .025 in - .025

Building a Part Number

XX= No. of conductors: 96, other conductor counts available upon requestYYY = Put-Up (ft.): 200*DL version available, part number 20098-XX-P-00YYY, 20099-XX-P-00YYY

20050 Pitch: 0.025 in (0.635 mm)

.026±

.002

.025 ± .002

Other conductor counts and put-ups available upon request. Standard multicolor is Red, White, Blue, White, Blue, White, Blue, White, Blue, White, repeat. PVC - DL: Heat bonded PVC insulated wires with dual lamina-tion tapes. PVC - NL: Heat Bonded PVC insulated wires with no lamination tapes.

UL/cUL Listing: 20528 UL/cUL Temp: 105°CUL/cUL Voltage: 150V UL/cUL Flame Rating: VW-1

PHYSICAL CONSTRUCTION DESCRIPTION HCA Micro Quick-Twist is built with 30 AWG stranded tinned copper. Each conductor is individually extruded with PVC. Conductors are pulled into pairs then bonded into flat sections for Insulation Displacement Connector (IDC) termination points. A Bonding Method requiring no lamination tape (NL) is used on the flat sections of 23195 and 20050 and the Dual Lamination Tape Bonding Method (DL) is used on 20098 and 20099.

Page 17: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

PHYSICAL CONSTRUCTION DESCRIPTION HCA TPO Micro Quick-Twist is built with 30 AWG stranded or solid tinned copper. Each conductor is individually extruded with TPO. Conductors are pulled into pairs then bonded into flat sections for Insulation Displacement Connector (IDC) termination points. A Bonding Method requiring no lamination tape (NL) is used on the flat sections of 20051 and 20062 and the Dual Lamination Tape Bonding Method (DL) is used on 20089, 20090. 20095, 20096, 20187 and 20188.

.026±

.002

.025 ± .002

Pitch tolerance ± .002 inches (± .050 mm)

Excellent noise and crosstalk reduction characteristics

Ideal for IDC termination with high density connectors

UL approved

APPLICATIONS Internal hard drives, SCSI, SPI, SPI-2, SPI-3, SPI-4, and U1 and U2 servers

U320 LVD and SE applications

Compliant for SCSI Fast-XX, SPI-2, SPI-3 U160 LVD, SPI-4

Micro Quick-Twist TPO Stranded 17

MQT MQTMicro Quick-Twist PVC Stranded 0.025 inch (0.635 mm) Micro Quick-Twist TPO Stranded & Solid 0.025 inch (0.635 mm)

• 20098 , 20051, 20188, 20187, 20095, 20089, 20096, 20090• Conductor Count: 68• Put-Up: 200 (60.96 m)• Conductor AWG: 30 7/38 AWG TC • Insulation: TPO-NL• Conductor Resistance ohms/1000 ft (ohms/Km): 106 (347.6)

Part Number

Capacitance Impedance Propagation Delay Width Span Ground-Signal

(G-S)

pF/ft (pF/m)

Ground-Signal (G-S-G)

pF/ft (pF/m)

(G-S-G)SE - Single End

(G-S) Differential

Nanoseconds/ft (ns/m) (ns/m)

Maximum Skew ns/ft (ns/m)

20062-68 -P-00200 10.3 (33.78) 13.0 (42.64) 95 ohms 120 ohms 1.56 (5.116) 0.035 (0.114)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

20051-68-P-00200 10.8 (35.78) 14.0 (45.92) 95 ohms 120 ohms 1.56 (5.116) 0.035 (0.114)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

20088-68-P-00200 11.0 (36.08) 16.5 (54.12) 86 ohms 125 ohms 1.45 (4.756) 0.025 (0.082)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

20087-68-P-00200 11.0 (36.08) 16.5 (54.12) 86 ohms 125 ohms 1.45 (4.756) 0.025 (0.082)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

20095-68-P-00200 10.4 (34.11) 14.0 (45.92) 88 ohms 120 ohms 1.56 (5.116) 0.025 (0.082)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

20089-68-P-00200 10.0 (32.8) 14.0 (45.92) 88 ohms 117 ohms 1.50 (4.92) 0.025 (0.082)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

20096-68-P-00200 11.0 (36.08) 15.0 (49.2) 86 ohms 115 ohms 1.56 (5.116) 0.035 (0.114)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

20090-68-P-00200 11.0 (36.08) 15.0 (49.2) 86 ohms 115 ohms 1.56 (5.116) 0.035 (0.114)Width: 1.700 in (43.18 mm)Span: 1.675 in (42.54 mm)

Standard multicolor is Red, Light Yellow, Blue, Light Yellow, Blue, Light Yellow, Blue, Light Yellow, Blue, Light Yellow, repeat for all stranded constructions. TPO - DL: Heat bonded TPO insulated wires with dual lamination tapes. TPO - NL: Heat Bonded TPO insulated wires with no lamination tapes.

UL/cUL Listing: 21057 UL/cUL Temp: 90°CUL/cUL Voltage: 150V UL/cUL Flame Rating: VW-1

Page 18: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

Round to Flat Ribbon18

ROUNDRound to Flat Ribbon

Available unshielded and double shielded

Shielded includes an aluminum tape and braid

Cable core features our 0.050 inch (1.27 mm) pitch gray ribbon cable foruse with popular IDC connectors. Core is slit 1.50 inch (38.1 mm) thenbonded 0.75 inch (19.05 mm) for ease of termination

APPLICATIONS Internal and external wiring of electronic equipment and consumer products

PHYSICAL CONSTRUCTION DESCRIPTION Cable core consists of slit and bonded flat gray ribbon cable. Core is folded and twisted into a round format before being taped with either Polyester (23149) or Aluminum/Polyester (23122) tape (Al side out). For dual shielded versions, cable is then braided. The core is jacketed in Black PVC.*

PVC JACKET

Ref. OD

BRAID SHIELD

W

ALUMINUM / POLYESTER TAPE

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23122 - 16 - P - 00660 16 660 ft201 m

Width: 0.400 in (10.16 mm)Span: 0.375 in (9.52 mm)

Example 2 23122 - 60 - P - 00660 60 660 ft201 m

Width: 1.500 in (38.10 mm)Span: 1.475 in (37.46 mm)

• 23122 - XX - P - 00YYY • Conductor AWG: 28 7/36 AWG TC • Insulation: PVC • Shielding: Al/PET Tape & Braid• Jacket: PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 24.5 (80.36)• Impedance (G-S-G): 65 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.62 (5.31)

Part Number Format

23122- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

23122

XX= No. of conductors: 16, 20, 25, 26, 34, 37, 40, 50, 60YYY = Put-Up (ft.): 660

# of Conductors 16 20 25 26 34 37 40 50 60

Jacket OD Inches mm

0.275 6.985

0.309 7.849

0.313 7.95

0.318 8.077

0.363 9.22

0.351 8.915

0.413 10.49

0.438 11.125

0.458 11.633

Part Number # of

ConductorsPut-Up

Width “W” Span “S”

Example 1 23149- 16 - P - 00660 16 660 ft201 m

Width: 0.400 in (10.16 mm)Span: 0.375 in (9.52 mm)

Example 2 23149- 50 - P - 00660 50 660 ft201 m

Width: 1.250 in (31.75 mm)Span: 1.225 in (31.11 mm)

• 23149 - XX - P - 00YYY • Conductor AWG: 28 7/36 AWG TC • Insulation: PVC • Shielding: PET Tape • Jacket: PVC• Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)• Capacitance Ground-Signal (G-S) pF/ft (pF/m): 24.5 (80.36)• Impedance (G-S-G): 90 ohms• Propagation Delay Nanoseconds/ft (ns/m): 1.62 (5.31)

Part Number Format

23149- XX - P - 00YYY XX 00YYYWidth: XX * .050 in

Span: XX* .050 in - .050

Building a Part Number

23149

XX= No. of conductors: 16, 20, 25, 26, 34, 37, 40, 50, 60YYY = Put-Up (ft.): 660

# of Conductors 16 20 26 40 50

Jacket OD Inches mm

0.275 6.985

0.309 7.849

0.318 8.077

0.413 10.49

0.438 11.125

Other conductor counts and put-ups available upon request. This product is available in 30 AWG solid and stranded construc-tions. Please consult with factory for more information. *Standard jacket color is Black. Other colors are available by special request.

UL/CSA Listing: (UL) CM c(UL) 105°C CSA Style: AWM llB, 300V, 105°CUL Style: 20381, 300V, 105°C

SOLUTIONS

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Page 19: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

19

ROUNDRound to Flat Ribbon

HCA Solutions

SOLUTIONSOther Products by HCA

Rev 08/2016

HITACH

I CABLE AMERICA IN

C.PREM

ISE & FIBER O

PTIC CABLE CATALOG

900 Holt Avenue, Manchester, New Hampshire 03109 USATel: +1-603-669-4347 Fax +1-603-669-9621

www.hca.hitachi-cable.com

WORLDWIDE COVERAGE

Rev 07/2016

PREMISE & FIBER OPTIC CABLE CATALOG

Hitachi Cable Industrial Ethernet cables are designed and manufactured at our modern

300,000 square-foot facility in Manchester, New Hampshire, USA. Hitachi Cable, one of the

largest cable manufacturing companies in the world, operates manufacturing facilities in six

continents producing thousands of different cable products.

In addition to Industrial Ethernet cables, the Manchester facility also manufactures Category

5e, 6 and 6A copper communication cables, round and flat electronics cables and a vast

selection of singlemode and multimode fiber optic cables.

For more information about Hitachi Cable products, please contact the Manchester facility.

900 Holt Avenue, Manchester, New Hampshire 03109 USATel: +1-603-669-4347 Fax +1-603-669-9621

www.hca.hitachi-cable.com

DELIVERING TODAY’S INFORMATION AT TOMORROW’S SPEED

07/2013

WORLDWIDE COVERAGE

Ultrasound . Medical . Inspection Interconnect Solut ions

HCA has a long history of designing and manufacturing a complete line of high-performance copper and fiber optic communication cables including Category 6, 6A and 7 cables. Our dedication to engineering perfection is evident in the consistent quality and performance of all the cable products we manufacture.

Premise & Fiber Optic Cable

To accommodate a wide variety of applications, Hitachi Cable offers dozens of unique designs intended to meet your specific needs. From high-flex to static, solid conductor to stranded, high and low temperature, oil and chemical resistant, we have the right industrial Ethernet solution.

Cabling Solutions for Industrial Ethernet

Our medical core technologies include advanced material development, ultra-fine wire capability, MCX (Micro-Coaxial Cable) technology yields long flex-life with tight electrical parameter control (Micro twinax cable is also available), bundled cable with fine wire coaxials for customer specific designs and ultra-high density MCX cable designs deliver a soft, but robust, feel for customer applications.

Medical Cable Solutions

Hitachi Cable’s coaxial cables are engineered with a wide selection of gauges and materials, with each offering the benefits for mechanical, electrical and cost consideration applications. Industrial applications include high power and environmentally rugged materials for use in robust applications.

Coaxial & Mini-Coaxial Cable

www.hca.hitachi-cable.com www.hca.hitachi-cable.com

Page 20: ADVANCED FLAT CABLE SOLUTIONS - Hitachi Cable … ·  · 2018-03-31ADVANCED FLAT CABLE SOLUTIONS. ... Call Us..... Hitachi Cable America. Flat Ribbon Cable ... SCSI, Ultra-ATA and

The Flat Cables in this catalog are designed and manufactured at our modern 300,000 square foot (27870.912 square meters) facility located in the East Industrial Park of Manchester, New Hampshire, USA.

In addition to a full line of high performance Electronics Cables, Hitachi Cable manufactures a wide range of HCA Brand cables to meet the demands of diverse markets throughout the world. For complete information, please contact your local representative or our inside sales team at +1.800.772.0116 or +1.603.669.4347.

9/2016

WORLDWIDE COVERAGE

900 Holt Avenue, East Industrial Park • Manchester, New Hampshire 03109 USATel: +1.603.669.4347 • Sales: +1.800.772.0116 • Fax: +1.603.669.9621

www.hca.hitachi-cable.com

www.hca.hitachi-cable.com www.hca.hitachi-cable.com