22
Adsorption Refrigeration System

Adsorption Refrigeration System. INTRODUCTION Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Embed Size (px)

Citation preview

Page 1: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Adsorption Refrigeration System

Page 2: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

INTRODUCTION

Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling effect.

Adsorption systems mainly use a natural working fluid which have zero ozone depletion potential.

However, the adsorption cooling machines still have some disadvantages that hinder their wide application.

Inventors propose technologies to improve adsorption system and make it become a realistic alternative.

An assessment is made about current development of adsorption refrigeration technologies.

Page 3: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Simple Adsorption cooling system

Page 4: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

One bed adsorption system by

Monma and Mizota in 2005

Page 5: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Disadvantages of One Bed adsorption system

Intermittent cooling effect

Low Coefficient of Performance (COP)

Long Cycle Time

Low Specific Cooling Power (SCP)

Page 6: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

SILICA GEL/WATER ADSORPTION CHILLER INTEGRATEDIN SOLAR COOLING SYSTEM by Dr. Uli Jakob in 2008

Step 1: Desorption – Drying of the adsorbentThe adsorbent is dried by heat input. Water

vapour is set free, flows in the condenser and is liquefied there under heat emission. When the material is dry, the heat input in the adsorber is stopped and the upper check valve closes.

Page 7: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

SILICA GEL/WATER ADSORPTION CHILLER INTEGRATEDIN SOLAR COOLING SYSTEM by Dr. Uli Jakob in 2008

Step 2: Adsorption – water vapour is adsorbed at the surface of

the adsorbent. After a cool down phase the reverse reaction and the evaporation of the liquid refrigerant starts. The lower check valve to the evaporator opens and the dry adsorbent aspirates water vapour. In the evaporator, water evaporates and generates cold.

Page 8: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

SILICA GEL/WATER ADSORPTION CHILLER INTEGRATEDIN SOLAR COOLING SYSTEM by Dr. Uli Jakob in 2008

Step 3: Return of condensateIn a final step, the liquid condensate is returned

to the evaporator and the circuit is closed.

Page 9: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Fig. Internal construction of the adsorption chiller.

Page 10: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Technical data ACS 08Cooling Capacity 7.5 kWThermal COP 0.56Electricity Consumption 9 WChilled Water Circuit 18/15 °C at 2.0 m³/hHeat Rejection Circuit 27/32 °C at 3.7 m³/hHeat Supply Circuit 72/67 °C at 1.6 m³/h

Page 11: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

A Hybrid Solar powered water Heater and Refrigerator by R.Z. Wang in 2000

Page 12: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

The working principle is just a combination of a solar water heater and adsorption refrigeration.

Heating of the water tank is started in the morning through vacuum tube type solar collector. With the increasing of the water temperature, the temperature in the adsorbent bed rises.

When the adsorbent temperature rises up desorption of the water vapour is get started from the bed at constant pressure. The desorbed vapor is condensed in the condenser and collected in the receiver.

The liquid flows to the evaporator via an flow rate regulating valve. A maximum temperature of 80–100°C could be achieved at the end of the

process hot water in the tank could be drained out and moved into another tank

thus hot water can be used very flexibly. With the refilling of the water tank with cold water, the temperature of the

adsorbent bed is reduced rapidly and the pressure in the adsorber drops to a value below evaporation pressure .

Evaporation could happen if the connecting valve is open, Refrigeration

will continue for the whole night until the next morning.

Page 13: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Rotary thermal regenerative adsorption device by R.E. Critoph in 2001

A refrigeration/heat-pump system based on a number of simple tubular adsorption modules.

A single module is comprised of a generator and a receiver/condenser/evaporator

Page 14: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Fig 1 Rotary thermal regenerative adsorption device

Page 15: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Fig. 2 Section through the generators.

Page 16: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Sixteen modules are shown, arranged in a cylindrical shell. All rotate about the central axis.

Air is blown over the tubes, counterflow to their direction of motion and exchanging heat with them.

The carbon is at its coldest, perhaps 50ºC and has maximum concentration at position 1 in fig 2.

As it moves clockwise through the annular duct it is heated by air flowing in the opposite direction.

The carbon is heated it desorbs ammonia which condenses in the receiver section of the module. The module reaches the end of the desorption section it is perhaps at 200º C.

A similar process occurs in the adsorbing section, but with evaporation occurring in the receiver, which cools the airstream passing over it.

All rotate about the central axis typically completing one revolution in 10 min

Page 17: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Heat recovery adsorption refrigeration cycles by R.Z. Wang in 2000

Page 18: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

A two beds continuous adsorption refrigeration system with heat recovery is shown in Fig. 1

When adsorber 1 is cooled and connected to the evaporator to get adsorption refrigeration in the evaporator.

Adsorber 2 is heated and is connected to the condenser to get heating–desorption–condensation.

The condensed refrigerant liquid flows into evaporator via a flow control valve.

The operation phase can be changed, and the go-between will be a short time heat recovery process in which the two pumps drive the thermal fluid in the circuit between two adsorbers. (the connection to the heater and cooler are blocked during this process).

Heat recovery is important to increase the cycle COP.

Page 19: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Solar-Powered Rotary Solid Adsorption Refrigerator by Aiping Zheng Juan Gu in 2004

Page 20: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

The low-pressure refrigerant vapor with low temperature from evaporator is introduced to the 3/5 area of the nether part of the rotary adsorbent bed by the gas circulation pump.

it will be adsorbed by the activated carbon fibre, adsorption heat released from the adsorbing course will be taken away by the refrigerant vapor not adsorbed and then enters the solar energy heater.

The refrigerant vapor will be heated by the solar energy heater and its temperature will rise gradually, and it will enter the 2/5 area of the upper part of the rotary adsorbent bed.

The refrigerant will desorbed from the activated carbon fibre when it is heated by the high temperature vapour refrigerant.

the refrigerant is condensed in the condenser by the cooled water. After being throttled its pressure is reduced, the liquid refrigerant will

enters the evaporator. In the evaporator, the low-pressure refrigerant liquid will adsorb the

heat from the cooled medium, and then it will be gasified into refrigerant vapor.

Then the low-pressure low temperature refrigerant vapor will be channeled into the 3/5 area of the under part of the rotary adsorbing

bed by the gas pump again and the cycle repeats.

Page 21: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Conclusion For adsorption refrigeration system, significant

achievements have been obtained on the use of various technologies to reduce the complexity of system structure, initial cost, to increase the system operation reliability as well as energy performance.

However, intensive research is still needed to: i) enhance the amount of recovered thermal

energy, without adding complexity into the design and operation of system

ii) optimize the recovered mass rate to achieve the best effect.

Applied material research could produce new combined material in order to achieve a higher SCP for adsorption refrigeration system.

Page 22: Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling

Thanks