Addressable range
8/7/2019 Addressable systemt
2/24
Addressable range
Control periodically and centralizes the state of theaddressable emergency lighting in a central controlpanel.
Manages the schedules of the emergency lightingunits automatic tests.
Helps the maintenance team to prepare and achievethe maintenance.
Inform the maintenance manager that a faulty units
level has been reached ( alarm contact, E-mail )
8/7/2019 Addressable systemt
3/24
Addressable range
Its not necessary to walk intoall the building to check thestate of the safety lighting.
The objective:
8/7/2019 Addressable systemt
4/24
C entral control panel unit
Supervision software
Repeater
Addressable range
A ddressable luminaires
8/7/2019 Addressable systemt
5/24
Addressable system
Big buildingLittle Building Different sites
All size of building is the target
8/7/2019 Addressable systemt
6/24
Its capacity: 1023 addressable emergencyLighting units ( whit repeaters )
Addressable system
8/7/2019 Addressable systemt
7/24
Addressable system
8/7/2019 Addressable systemt
8/24
Addressable system
Its capacity: 1023 addressable emergencyLighting units ( whit repeaters ).4 ways to connect the central control panel to aPC.
8/7/2019 Addressable systemt
9/24
PC/control panel connection by direct RS232 link.
Addressable system
8/7/2019 Addressable systemt
10/24
PC/control panel connection by RS 485 network.
Addressable system
8/7/2019 Addressable systemt
11/24
PC/control panel connection by Ethernet.
Addressable system
8/7/2019 Addressable systemt
12/24
Various connection modes are possible
T he addressable offer
PC/control panel connection by Modem link.
8/7/2019 Addressable systemt
13/24
Its capacity: 1023 addressable emergencyLighting units ( whit repeaters ).4 ways to connect the central control panel to aPC.
1 SubD-25 pin socket in available to connect aexternal printer
Addressable system
8/7/2019 Addressable systemt
14/24
Addressable system
T he concept of addressing.
Allows to identify directlyeach addressable EL unitusing a clear address from
Zone name: 3 characters
Order number: 3 numbers
8/7/2019 Addressable systemt
15/24
Addressable system
Functionality of the central unit
8/7/2019 Addressable systemt
16/24
Addressable system
Functionality of the central unit
8/7/2019 Addressable systemt
17/24
Addressable system
Functionality of the central unit
8/7/2019 Addressable systemt
18/24
Addressable system
Functionality of the central unit
8/7/2019 Addressable systemt
19/24
T he managing system:
T he functions of the software
T he whole plans of the installation can be imported in the software Autocad layers or similar ( DXF format ) Scanned plans or image ( GIF or JPG format )
Each EL unit can be placer on the corresponding background plans withits real picture, enhanced with the detailed location and its competespecification.
Each faulty EL units can be easily located on the plans with its type of fault, directly corresponding icons.
Addressable system
8/7/2019 Addressable systemt
20/24
T he managing system:
Display of a synthetic board of the installation to have anoverview of the state of the EL installation
Split from the structure of the building Showing the number (and %) of the faulty EL units relating to
the total number of addressable EL units, for each part of thebuilding.
Maintenance assistance Automatic edition of the list of the spare parts to be replaced,
necessary to be prepared ( or ordered ) in order to repair theEL faulty units.
Addressable system
8/7/2019 Addressable systemt
21/24
T he managing system :
Maintenance assistance
Automatic edition of the work-sheet with the list of faulty ELunits with their complete location, their type of fault and spare
part number. Automatic checking of all repair EL units. No limit in quantities of addressable EL units or central
control panel.
Addressable system
8/7/2019 Addressable systemt
22/24
T he managing system:
From anywhere, the software can be accessible from any PC of the building through the intranet network.
Easy to use, the user will see together the whole EL units on theplans of the building, even if there are several central controlpanels in one building.
You can start an alarm manager in background task to controlperiodically the system and to inform the maintenance manager
Addressable system
8/7/2019 Addressable systemt
23/24
T he managing system:
Addressable system
8/7/2019 Addressable systemt
24/24
If one of the BAES is fault, automatic obtaining one file with thespare parts list of this BAES and possibility to modify the file(quantities, part number,)
Possibility to create a board with identification of BAES who arefaulty and list of the spare part: intervention file (optimisation of themaintenance contract)
Checking immediately of the repair (less manipulation)
Addressable systemUsing for the with maintenance