8
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions Decentralized Drive, Positioning and Application Controller MOVIPRO ® SDC / ADC Edition 06/2011 19305613 / EN

Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving

Embed Size (px)

Citation preview

Page 1: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving

Drive Technology \ Drive Automation \ System Integration \ Services

Addendum to theOperating Instructions

Decentralized Drive, Positioning and Application ControllerMOVIPRO® SDC / ADC

Edition 06/2011 19305613 / EN

Page 2: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving

SEW-EURODRIVE—Driving the world

Page 3: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving

1Other applicable documentationGeneral Information

1 General Information1.1 Other applicable documentation

This document supplements the MOVIPRO® operating instructions and limits theapplication notes according to the following information. Only use this document inconnection with the MOVIPRO® operating instructions.

2 Function Units2.1 Power section

The following information has been added to the chapter "Unit structure" / "Functionunits" / "Power section":

2.2 Communication and control unitThe following information has been added to the chapter "Unit structure" / "Functionunits" / "Communication and control unit":

3 Electrical Installation3.1 Connection block

P F A - MD .. - BG 02 - ..Brake control voltage:02 = DC 24 V

P F H - .. - B 64 - ..Bus connection type:64 = 2 × Push-pull SCRJ

3457668875[1] X4234_11 Ethernet fieldbus (Push-pull SCRJ)[2] X4234_12 Ethernet fieldbus (Push-pull SCRJ)

[1] [2]

Addendum to the Operating Instructions – MOVIPRO®

3
Page 4: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving

4

4 lectrical connectionsperation

3.2 Electrical connections3.2.1 X4234: Ethernet fieldbus

The following table informs about this connection:

4 Operation4.1 Status LEDs FO1 and FO2 Ethernet connection push-pull SCRJ

The two LEDs "FO1" and "FO2" indicate the signal quality of the respective optical trans-mission line.

The following figure shows the positions of the two LEDs:

Function

Ethernet fieldbus interface, SCRJ / POF

Connection type

Push-pull SCRJ

Wiring diagram

3419100299

Assignment

No. Name Function

1 Tx Transmitting line (POF)

2 Rx Receiving line (POF)

1 2

4083348491[1] FO1[2] FO2

LED status Status or cause of error Remedy

Off The signal level is 2 dB or more. The signal quality is good. –

Lights up yellow

The optical signal level has fallen below 2 dB.This can have the following reasons:• Aging effect of the polymer fiber• The plug connector is not properly

connected.• The externally connected cable is

faulty or damaged.

• Check whether the plug connector is properly connected.

• Check the attenuation of the exter-nally connected cable.

[1] [2]

EO

Addendum to the Operating Instructions – MOVIPRO®

Page 5: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving

5Version with operating point 400 V/50 HzTechnical Data

5 Technical Data5.1 Version with operating point 400 V/50 Hz

The following information has been added to the technical data:

5.2 Brake control5.2.1 DC 24 V

MOVIPRO®

Size Size 0 Size 1 Size 2

Performance class 2.2 kW 4.0 kW 7.5 kW 11.0 kW 15.0 kW

Ambient temperature

ϑ A

+5 – +40 °C (+41 – +104 °F), Non-condensing, no moisture condensation;

The unit provides intrinsic thermal safety.

(PN reduction: 3% per K up to a maximum of 60 °C or 50 °C in units with push-pull SCRJ)

Brake control DC 24 V

Brake voltage VB DC 24 V

Nominal output current IN DC 1.4 A

Acceleration current IB –

Max. output power PO 33 W

Brake type The data refer to SEW brakes BP01 – BP5(single-coil system, no acceleration)

Addendum to the Operating Instructions – MOVIPRO®

5
Page 6: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving
Page 7: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving
Page 8: Addendum to the Operating Instructions · PFH-..-B64-.. Bus connection type: 64 = 2 × Push-pull SCRJ ... Assignment No. Name Function 1 Tx Transmitting line (POF) 2 Rx Receiving

SEW-EURODRIVE—Driving the world

SEW-EURODRIVEDriving the world

www.sew-eurodrive.com

SEW-EURODRIVE GmbH & Co KGP.O. Box 3023D-76642 Bruchsal/GermanyPhone +49 7251 75-0Fax +49 7251 [email protected]