ACTOM Outdoor MV Switchgear - Single

Embed Size (px)

Citation preview

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    1/8

    OUTDOOR MEDIUM VOLTAGE SWITCHGEAR - UP TO 24kV

    A division of ACTOM Pty Ltd

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    2/8

    1

    ACTOM Out doo r M edium Volt age Sw it chgear

    Rhino substations up to 24 kV

    • •

      handling and transporting the tion, metering and indicationhas been specifically designed to complete outdoor assembly. devices normally associatedhouse the SBV4 and SBV24 The outdoor enclosures can be with an indoor MV switchboard.range of vacuum switchgear so manufactured from mild steel All enclosure doors in front ofthis type of equipment may be plate or 3CR12 corrosion resis- the switch panels are designed toinstalled outdoors without the tant metal, dependent on the open into a horizontal positionnecessity of building a conven- us er ’s re qu i re men ts .A l l where the inside of the door istional brick type substation. steelwork is powder coated used as the runner to withdraw The SBV4 – 12 kV is a compact using the most up to date static

    the circuit breaker truck.range of switchgear available in deposition and baking tech- All doors are fitted with a tampersingle busbar arrangement with niques. proof locking system to preventa continuous rating of up to Enclosure bases are of the RSJ vandalism and access to the2000A and a rated short circuit type for rigidity and are hot dip MV compartments.capability up to and including galvanised for enhanced corro- Generous cable access space is31,5 kA for 3 seconds. sion resistance. available at the rear of the

     The SBV5 – 12kV is inter- Voltage transformers and enclosure for bottom entrychangeable with the SBV4 and battery tri pping uni ts are power cables.shares the same housing mounted in an end compartmentenclosure but uses an advanced together with the relay protecmagnetic actuator mechanismfor applications where a large

    number of switching operationsare required, for example, motoroperation and power factorcorrection device switching. Thisrange is available in singlebusbar arrangement with acontinuous rating of up to 1 250 Aand a rated short circuit capabil-ity up to and including 25 kA for 3seconds. The SBV24 – 24 kV is a compactrange of switchgear available insingle busbar arrangement with

    a continuous rating of up to1 250 A and a rated short circuitcapability up to and including25 kA for 3 seconds.All SBV4, SBV5 and SBV24medium voltage switchgearhave been tested at KEMA orNETFA.

     This range of switchgear isideally suited for fitting intooutdoor type steel enclosuresdue to the compact nature of the

    switchgear. Virtually any combi-nation or number of panels maybe accommodated, dependentonly on the limitations of

     The Rhino outdoor substation

    Rhino outdoor substation suitable for systems up to 24 kV.

    Rhino outdoor substation.

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    3/8

    2

    • ACTOM

      miniature substationshave been developed over manyyears as a cost effective methodof reticulating power to residen-tial, industrial and developmentareas where the essentialcomponents are combined in asingle robust enclosure suitablefor outdoor applications.

      M i n i a t u r e s u b s t a t i o n sgenerally consist of a steelenclosure housing an MV ringmain switch, a step-downtransformer with ratios typically 22 000/420 V or 11 000/420 Vand a low voltage di stri butioncompartment.

     The MV compartment maycontain one of the followingwhich are generally purchaserspecified:- 3-way oil insulated isolator ringmain unit type K3

    - 4-way oil insulated isolatorring main unit type K4- 3-way oil insulated isolator/airinsulated fuse ring main unittype K3/AF- 4-way oil insulated isolator/airinsulated fuse ring main unittype K4/AF- 3 or 4-way gas insulated ringmain unit

    Miniature substations up to 24 kV

    *Type B miniature substation with all compartment doors open.

    Front view of a type A miniature substation.

    A fibreglass miniature substation.

    Side view of a type A miniature substation.

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    4/8

    3

     The transformer compartmentcontains a sealed type oilimmersed step down trans -former of the low loss type withaluminium windings in accor -dance with SABS 780 and isnormally supplied with an oillevel indicator and an off circuittap switch. These transformerscan be supplied on request with

    dual inputs, for example, tooperate from either 11 000 V or6600 V medium voltage systems. The LV compartment containscircuit breakers, HRC fuses,metering and instruments tospecification.

      Miniature substations are norm-ally available in type A or type Bconfigurations dependent ont h e s p e c i f i c a t i o n . The units are factory assem-bled bled and tested anddespatched as complete unitsand are suitable for installationin public areas , such as onresidential pavements, nearshopping complexes and inindustrial parks.

      Miniature substation fitted withgas insulated ring main unitshaving an internal arc classifica-tion IAC AB in accordance withSANS 62271-202 are available.

    Miniature substation with IAC.

     Type B miniature substation suitable for systems up to 24 kV.

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    5/8

    4

    K-range oil switchgear up to 12 kV

    ••

    ••

    ••

    ••

      Replacement of air insulatedprocedures during operationHRC fuses is simple, safe andand guard against tampering.rapid via robust safety interlocksSpring loading of switch mecha-from the front of the unit.nisms ensures that the speed ofAll units employ independentoperation of all contacts ismanual spring type mechanismsindependent of the operator.which are simple, robust andIntegral fault make earthingreliable.switches are provided.

     The designs incorporate lowAccess to HRC fuses on tee-off component counts, self aligningcircuits is restricted by interlocks

    switch blades and a minimumto ensure that both sides of theamount of maintenance.fuses are earthed.

     The K-range of switchgear hasAll ring isolators are fitted withbeen designed to satisfy afully interlocked test shutters todiversity of applications, for bothenable access for cable testing.indoor and outdoor use inFuse switches do not have thisextensible and non-extensiblefeature.

     The K-range of low oil volumeconfigurations.All major compartments are

    switchgear provides a versatile  The cab le cham ber s arefitted with pressure relief ventssolution for indoor and outdoor designed in various versions towhere pressures, created duringMV switching applications accommodate different types ofan internal arc fault, would be

    where both extensible and non- MV cables and different insula-directed away from the operator.extensible configurations are tion mediums, such as heat The volume of oil required for therequired, for use with distribu- shrink insulation and insulatingK-range ring main units istion equipment such as trans- compounds.substantially less than otherformers and cable networks.   K-range units are manufactured,comparable ring main units.

     The K-range switches are of the tested and certified in accor-  All operations on the K-rangefault make/load break type dance with IEC 420 (1990) andunits, including operation of thewhere either fuse switches or NRS 006.earthing switches, cable testisolators or combinations of ACTOM Switchgear compliesshutters and main cable access,these are required, depending with ISO 9000 quality require-are from the front of the unit.on the application. ments and is certificated to The versatility of this range of SABS/ISO 9001.switchgear is enhanced in that

    All K-range switchgear is fullynon-extensible units can be designed and manufactured insupplied with up to four circuits South Africa.in very compact dimensions  The K-range switchgear iswhereas the typical ring main tested and cert i f ied forunit is limited to three circuits. operation on systems:

     The non-extensible units are - Voltages up to 12 kVparticularly well suited for - Rated insulation level 12 kVfittinginto high voltage compart- - Impulse level (peak) 95 kVments of miniature substations

    - A.C. withstand 1min (rms)and outdoor steel kiosks. 28kV

      Personnel safety is the key - R ated curr ent 630 Afeature of the K-range of - Rated fault current (3 sec)switchgear in that the equipment

    20kAhas substantial mechanical - Max fuse rating (T-off) 90Ainterlocking devices to ensurethat users follow the correct

    K3 AF with fuse chamber open.

    K3 AF with additional outdoor enclosure.

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    6/8

    5

    • •

    ••

    • •

    FBX-C CCT2 RMU

    FBX-C 12k V and 24kV switchgear Both FBX-C (non-extensible) andgas handling, to form theis available as classical non- FBX-E (extensible) versions canrequired multi-panel switchgearextensible ring main units, with 2 be equipped with load-breakarrangement.to 4 switching units. fault-make switch disconnectorsWith its modular concept andFBX -E i s th e ex tens ib le (C), switch fuse combinationsoptions including motorizedversion, with 1 to 4 switching (T1), 630A vacuum circuit-switching devices and remoteunits, which are arranged in a breakers (T2), busbar risers (R)control modules, FBX isc o m m o n g a s - f i l l e d and busbar risers with earthespecially well-suited for thecompartment. switches (RE).increasing automation of

     The functional units of FBX-E can T h e cab l e te r m i n at i o ns e c o n d a r y d i s t r i b u t i o nbe arranged in any order, without compartments are fitted with

    networks.  Type C bushings suitable for 3-core medium-voltage cabletermination using shrouds,unscreened and screenedseparable connectors.Using screened separableconnectors it is possible to installtwo 3-core cables or one 3-corecable with three surge arrestersper cable compartment.

     The FBX-C CCT2 ring main unit,consisting of two load-break fault-make switch disconnectors (C)and a 630A vacuum circuit breaker(T2), is ideal for use in miniaturesubstations or free-standing in akiosk. A self-powered protectionrelay provides the protectionfunction for the circuit breaker(T2). The unit has integral cabletest facilities that are accessiblefrom the front without having to

    access the cable compartments.

    FBX Gas Insulated Ring Main Unit up to 24 kV

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    7/8

  • 8/18/2019 ACTOM Outdoor MV Switchgear - Single

    8/8

    www.actom.co.za

    Tel: +27 (0)11 820-5111

    2 Magnet Road

    Knights

    1413

    P O Box 13024

    Knights

    1413

    Fax: +27 (0)11 820-5122

    email: [email protected]