ACTIVE CORROSION MONITORING SUCCESSFUL CASE STUDIES
Miguel A. Gonzlez Nez Ph. D; Alain Proust Ph. D; Jean-Claude Lenain Ph. D; Valery Godinez Ph. D
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Acoustic Emission Basic Process and Definition
Words from
the Definition: . . . transient . . . elastic . . . waves . . . rapid . . . localized . . . source
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Scale of AE Source Processes
AE Source Amplitude will be Governed by (a) Size, (b) Speed of Source Event
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Corrosion of Steel Plate
Steel plates with thick oxide film generate very strong AE signals with amplitudes over 80 dB during the corrosion process in a NaCl solution. It was also found that the signals with lower frequencies (20 80 kHz) are dominantly produced during the process.
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Mechanism of SCC
=> Plastic blunting at crack tip
Step 1
Step 2
Step 3
Film formation
Brittle fracture
Environment
Film induced cleavage model
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Pitting and crevice
Dislocation at pit tip
Spalling of corrosion products
? ?
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Pitting and crevice
Salt crystal formation
H2 H+
H+ Hydrogen evolution
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Corrosion of Steel Plate
The amount of current applied was calculated from a polarization curve on a similar material to make sure that corrosion was developed.
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
9
Overview: Localized Corrosion Catastrophic ruptures of industrial
plants Long initiation time but high
propagation velocity Inspection frequency not adapted
to prevent in service failures Environment industrial and human
incidence $1.7 Billion corrosion costs
Chemical and Petrochemical Industry
Cost : 4% Turnover chemical industry (30% due to SCC)
Pitt
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
PRELIMINARY INFORMATION
Correlation between actual cracks position along the sample located events
1985 original idea according to fractographic examination Stress Corrosion Crack (SCC) propagation => AE
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Functions Selection Start a test Replay a test Data File transfer Delete File
Logistic Information Calibration Check out of the test feasibility (background noise level) Threshold Adjustment Data Acquisition (1 hour) Data stored on disk, report with graphs available ready for printing Calibration
1
2
3
4
5
6
7
8
ACTIVE CORROSION TEST DESCRIPTION, EASY TO USE
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Yes Propagation of localized corrosion No
Corrosion rate correlated with AE activity Data base for corrosion rate on specific asset No quantification corrosion damage
Use of traditional AE with external loading (pressure, thermal stress) IPAC/MONPAC or NDT
Diagnosis
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Acoustic Emission for anti-corrosion
Material has been chosen to resist to localised corrosion ! Corrosion could be a results of Process changes AE is NOT only a corrosion detection technique It is also a technique for expertise and for developing SOLUTIONS against corrosion Corrosion can be stopped or at least reduced if we know more about it
STRATEGY
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
14
Applications Insulated distillation column
Pipe supports Storage tanks Corrosion under insulation
(High/low temperature) Rail road Tank Car Al-Honeycomb Composites Enamel coated reactors Aerospace Industry: corrosion
protection characterization Detection of active corrosion
on grouted tendons on bridges
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Early detection on high risk installation Case N1
MATERIAL : Duplex stainless steel Medium Cl- at 80C
Early detection of SCC crack propagation with CORPAC => Pipe changed before leak SCC Cracks
Some cracks have been detected in one plant => CORPAC exam has been done on the other plant using similar process
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Risk based decision and corrosion monitoring SCC and Pitting, Case N 2
2 flat bottom storage tanks of 30 m3
Material : stainless steel (316Ti/19-25 HMo ST9)
In service temperature 90-100C
Organic Product
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Action: Cleaning the product and maintain water
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
1996 CORPAC Very few AE Conclusion : No propagating corrosion
1997 CORPAC Strong AE localized at liquid/gas interface
Process analysis : 1 month before a dryer reactor had failed water in the product
1998-2001 CORPAC Small rate of AE Conclusion : Reduced corrosion rate
Risk based decision and corrosion monitoring SCC and Pitting, Case N 2
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Question : How extent was the damaged area ?
Insulated distillation column (18m high)
In service temperature 150C
Material stainless steel (316 Ti)
Stress corrosion detected by dye penetrant
Damaged area characterization : SCC Case N3
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
AE activity restricted within a 2m high zone (cone)
confirmed partially with pulsed Eddy Current (only 4m were
inspected)
In Service AE Monitoring with CORPAC unit
Action : Partial repair with duplex stainless steel (2205)
Still in operation with any problems or leaks
Damaged area characterization : SCC Case N3
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Repair not Validated Case 4 Piping System Material : Inconel 600 Temperature : 100C
Diagnosis : ACTIVE localized corrosion Detected damage : SCC cracks Every repair increase the crack speed
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Heat Insulated Piping System Stainless steel 304L 1993 Leaks due to SCC cracks PT inspection => partially repaired in 1997 Paint + aluminum sheet + hydrophobic insulation + waterproof metallic shell Question : efficiency of anti corrosion protection?
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Use of Acoustic Emission to detect localised corrosion under passive
protection, illustrated with industrial examples
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Laboratory experiments: technical validation
10x 15 cm sample E24 low carbon steel plate
Protected with 400m of epoxy coating.
Before aging
One hour of AE monitoring in salt water : NO AE
AE TEST # 1
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Laboratory experiments: technical validation
2 AE measurements of 6 samples
Aging 2 months of immersion in salt water + 2 months
saline mist + UV light
AE TEST # 2 AE TEST # 3
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
0
200
400
600
800
1000
1200
1 2 3 4 5 6
Laboratory experiments: technical validation
Aging 2 months of immersion in salt water
+ 2 months saline mist + UV light
AE activity VS sample number
+
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Case history N9: Internal Coating Characterization Rail road tankcar (out of service) Corrosion protection ebonite
Artificial defects
on internal ebonite coating
3 drilled holes
(2, 5, 10 mm diameter)
Filled with industrial water
Rhoditech
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED. Rhoditech
Artificial defects
outlet
Top side near man
way
Case history N9: Internal Coating Characterization
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Results :
AE from an artificial defect of ebonite coating AE from the top side near man way: in service defect AE from bottom side outlet: in service defect
Coating is degraded (change of color but not detectable with electrical measurements)
Addition of 60 liters of chloride acid strong increase of AE activity up to 1 event/sec
Rhoditech
Case history N9: Internal Coating Characterization
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Annular Ring on Storage Tanks
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
AE Expert System
Early detection on high risk installation (without shutdown) Zonal location of damaged area Corrosion monitoring identification of transient stage which promotes localized corrosion characterization of corrosion rate
Validation of repair or corrosion protection Help for in situ material choice
Diagnosis
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Non Intrusive Real Time Corrosion Monitoring
CORPAC TECHNOLOGY a) Find areas of active local
corrosion in pipes or vessels 1m (3ft) radius from AE sensor
b) Specific Areas (Welds, narrow geometries)
c) Large Areas can be tested with a multichannel system
d) Identify process stage or tweak process parameters to eliminate active corrosion
2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.
Thank you for your interest
Contact us at (609) 716-4080
E-mail: [email protected] www.mistrasgroup.com
Active Corrosion Monitoring Successful Case StudiesAcoustic Emission Basic Process and DefinitionScale of AE Source ProcessesCorrosion of Steel PlateMechanism of SCCPitting and crevicePitting and creviceCorrosion of Steel PlateOverview: Localized CorrosionPRELIMINARY INFORMATIONNmero de diapositiva 11Nmero de diapositiva 12Nmero de diapositiva 13ApplicationsEarly detection on high risk installationCase N1Nmero de diapositiva 16Nmero de diapositiva 17Nmero de diapositiva 18Nmero de diapositiva 19Nmero de diapositiva 20Repair not Validated Case 4Heat Insulated Piping SystemNmero de diapositiva 23Nmero de diapositiva 24Nmero de diapositiva 25Nmero de diapositiva 26Nmero de diapositiva 27Nmero de diapositiva 28Nmero de diapositiva 29Annular Ring on Storage TanksAE Expert SystemNon Intrusive Real Time Corrosion MonitoringNmero de diapositiva 33