    ACTIVE CORROSION MONITORING SUCCESSFUL CASE STUDIES

    Miguel A. Gonzlez Nez Ph. D; Alain Proust Ph. D; Jean-Claude Lenain Ph. D; Valery Godinez Ph. D

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Acoustic Emission Basic Process and Definition

    Words from

    the Definition: . . . transient . . . elastic . . . waves . . . rapid . . . localized . . . source

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Scale of AE Source Processes

    AE Source Amplitude will be Governed by (a) Size, (b) Speed of Source Event

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Corrosion of Steel Plate

    Steel plates with thick oxide film generate very strong AE signals with amplitudes over 80 dB during the corrosion process in a NaCl solution. It was also found that the signals with lower frequencies (20 80 kHz) are dominantly produced during the process.

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Mechanism of SCC

    => Plastic blunting at crack tip

    Step 1

    Step 2

    Step 3

    Film formation

    Brittle fracture

    Environment

    Film induced cleavage model

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Pitting and crevice

    Dislocation at pit tip

    Spalling of corrosion products

    ? ?

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Pitting and crevice

    Salt crystal formation

    H2 H+

    H+ Hydrogen evolution

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Corrosion of Steel Plate

    The amount of current applied was calculated from a polarization curve on a similar material to make sure that corrosion was developed.

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    9

    Overview: Localized Corrosion Catastrophic ruptures of industrial

    plants Long initiation time but high

    propagation velocity Inspection frequency not adapted

    to prevent in service failures Environment industrial and human

    incidence $1.7 Billion corrosion costs

    Chemical and Petrochemical Industry

    Cost : 4% Turnover chemical industry (30% due to SCC)

    Pitt

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    PRELIMINARY INFORMATION

    Correlation between actual cracks position along the sample located events

    1985 original idea according to fractographic examination Stress Corrosion Crack (SCC) propagation => AE

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Functions Selection Start a test Replay a test Data File transfer Delete File

    Logistic Information Calibration Check out of the test feasibility (background noise level) Threshold Adjustment Data Acquisition (1 hour) Data stored on disk, report with graphs available ready for printing Calibration

    1

    2

    3

    4

    5

    6

    7

    8

    ACTIVE CORROSION TEST DESCRIPTION, EASY TO USE

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Yes Propagation of localized corrosion No

    Corrosion rate correlated with AE activity Data base for corrosion rate on specific asset No quantification corrosion damage

    Use of traditional AE with external loading (pressure, thermal stress) IPAC/MONPAC or NDT

    Diagnosis

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Acoustic Emission for anti-corrosion

    Material has been chosen to resist to localised corrosion ! Corrosion could be a results of Process changes AE is NOT only a corrosion detection technique It is also a technique for expertise and for developing SOLUTIONS against corrosion Corrosion can be stopped or at least reduced if we know more about it

    STRATEGY

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    14

    Applications Insulated distillation column

    Pipe supports Storage tanks Corrosion under insulation

    (High/low temperature) Rail road Tank Car Al-Honeycomb Composites Enamel coated reactors Aerospace Industry: corrosion

    protection characterization Detection of active corrosion

    on grouted tendons on bridges

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Early detection on high risk installation Case N1

    MATERIAL : Duplex stainless steel Medium Cl- at 80C

    Early detection of SCC crack propagation with CORPAC => Pipe changed before leak SCC Cracks

    Some cracks have been detected in one plant => CORPAC exam has been done on the other plant using similar process

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Risk based decision and corrosion monitoring SCC and Pitting, Case N 2

    2 flat bottom storage tanks of 30 m3

    Material : stainless steel (316Ti/19-25 HMo ST9)

    In service temperature 90-100C

    Organic Product

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Action: Cleaning the product and maintain water

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    1996 CORPAC Very few AE Conclusion : No propagating corrosion

    1997 CORPAC Strong AE localized at liquid/gas interface

    Process analysis : 1 month before a dryer reactor had failed water in the product

    1998-2001 CORPAC Small rate of AE Conclusion : Reduced corrosion rate

    Risk based decision and corrosion monitoring SCC and Pitting, Case N 2

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Question : How extent was the damaged area ?

    Insulated distillation column (18m high)

    In service temperature 150C

    Material stainless steel (316 Ti)

    Stress corrosion detected by dye penetrant

    Damaged area characterization : SCC Case N3

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    AE activity restricted within a 2m high zone (cone)

    confirmed partially with pulsed Eddy Current (only 4m were

    inspected)

    In Service AE Monitoring with CORPAC unit

    Action : Partial repair with duplex stainless steel (2205)

    Still in operation with any problems or leaks

    Damaged area characterization : SCC Case N3

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Repair not Validated Case 4 Piping System Material : Inconel 600 Temperature : 100C

    Diagnosis : ACTIVE localized corrosion Detected damage : SCC cracks Every repair increase the crack speed

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Heat Insulated Piping System Stainless steel 304L 1993 Leaks due to SCC cracks PT inspection => partially repaired in 1997 Paint + aluminum sheet + hydrophobic insulation + waterproof metallic shell Question : efficiency of anti corrosion protection?

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Use of Acoustic Emission to detect localised corrosion under passive

    protection, illustrated with industrial examples

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Laboratory experiments: technical validation

    10x 15 cm sample E24 low carbon steel plate

    Protected with 400m of epoxy coating.

    Before aging

    One hour of AE monitoring in salt water : NO AE

    AE TEST # 1

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Laboratory experiments: technical validation

    2 AE measurements of 6 samples

    Aging 2 months of immersion in salt water + 2 months

    saline mist + UV light

    AE TEST # 2 AE TEST # 3

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    0

    200

    400

    600

    800

    1000

    1200

    1 2 3 4 5 6

    Laboratory experiments: technical validation

    Aging 2 months of immersion in salt water

    + 2 months saline mist + UV light

    AE activity VS sample number

    +

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Case history N9: Internal Coating Characterization Rail road tankcar (out of service) Corrosion protection ebonite

    Artificial defects

    on internal ebonite coating

    3 drilled holes

    (2, 5, 10 mm diameter)

    Filled with industrial water

    Rhoditech

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED. Rhoditech

    Artificial defects

    outlet

    Top side near man

    way

    Case history N9: Internal Coating Characterization

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Results :

    AE from an artificial defect of ebonite coating AE from the top side near man way: in service defect AE from bottom side outlet: in service defect

    Coating is degraded (change of color but not detectable with electrical measurements)

    Addition of 60 liters of chloride acid strong increase of AE activity up to 1 event/sec

    Rhoditech

    Case history N9: Internal Coating Characterization

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Annular Ring on Storage Tanks

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    AE Expert System

    Early detection on high risk installation (without shutdown) Zonal location of damaged area Corrosion monitoring identification of transient stage which promotes localized corrosion characterization of corrosion rate

    Validation of repair or corrosion protection Help for in situ material choice

    Diagnosis

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Non Intrusive Real Time Corrosion Monitoring

    CORPAC TECHNOLOGY a) Find areas of active local

    corrosion in pipes or vessels 1m (3ft) radius from AE sensor

    b) Specific Areas (Welds, narrow geometries)

    c) Large Areas can be tested with a multichannel system

    d) Identify process stage or tweak process parameters to eliminate active corrosion

  • 2012 MISTRAS GROUP, INC. ALL RIGHTS RESERVED. DISSEMINATION, UNAUTHORIZED USE AND/OR DUPLICATION NOT PERMITTED.

    Thank you for your interest

    Contact us at (609) 716-4080

    E-mail: [email protected] www.mistrasgroup.com

    Active Corrosion Monitoring Successful Case StudiesAcoustic Emission Basic Process and DefinitionScale of AE Source ProcessesCorrosion of Steel PlateMechanism of SCCPitting and crevicePitting and creviceCorrosion of Steel PlateOverview: Localized CorrosionPRELIMINARY INFORMATIONNmero de diapositiva 11Nmero de diapositiva 12Nmero de diapositiva 13ApplicationsEarly detection on high risk installationCase N1Nmero de diapositiva 16Nmero de diapositiva 17Nmero de diapositiva 18Nmero de diapositiva 19Nmero de diapositiva 20Repair not Validated Case 4Heat Insulated Piping SystemNmero de diapositiva 23Nmero de diapositiva 24Nmero de diapositiva 25Nmero de diapositiva 26Nmero de diapositiva 27Nmero de diapositiva 28Nmero de diapositiva 29Annular Ring on Storage TanksAE Expert SystemNon Intrusive Real Time Corrosion MonitoringNmero de diapositiva 33