Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
ACTIVE BLACKBOX MANUALINDUSTRY4.0 IoT DEVICE
ABB-M200 / ABB-M200Z / ABB-M400
CONTENTS
01
02
03
04
05
06
07
08
09
하드웨어 사양
기본 구성품
각부 명칭 및 용도
외형 치수
VESA 브라켓 장착 방법
DIN Rail 35mm Fixed Clamp 장착 방법
Application 구성도
하드웨어 연결
시작하기
ABB-M200 / M200Z
ABB-M200/M200Z
ABB-M200/M200Z
직접 연결하기
VESA 브라켓
ABB-M400
ABB-M400
ABB-M400
원격 접속하기
DIN Rail 35mm Fixed Clamp
2
7
23
6
9
13
16
20
21
http://www.tiasolution.net2
ABB-M200 / M200Z 01. 하드웨어 사양
SYSTEM
I/O INTERFACE
WIRELESS NETWORK OPTIONAL CONFIGURATION
CPU : Intel Celeron Processor 3215U ( 2M Cache, 1.70GHz, Broadwell ) GPU : Onboard VGA( Intel HD Graphics )Memory : 4GB DDR3LStorage : mSATA 64GB* Memory, Storage can be Changed ( max 8GB, mSATA 128GB )
Display : 2 x HDMIAudio :1 x MIC In, 1 x Speak OutLAN : 2 x RJ-45 10/100 Base-TUSB Port : 2 x USB 2.0, 4 x USB 3.0COM Port : 4 x COMSIM Card : 1 x SIM card socket ( internal )
WLAN : IEEE 802.11 b/g/n, Range 50~100m ( ABB-SEN-T200WZ Maximum Connections 30 )ZIGBEE : IEEE802.15.4 ,Maximum Range 120m ( ABB-SEN-T200WZ Maximum Connections 30 )- Support Mini PCIe Type : Bluetooth Module, LTE( 3G ) Module*Two network configurations are possible.
http://www.tiasolution.net 3
ABB-M200 / M200Z 01. 하드웨어 사양
POWER REQUIREMENT
MECHANICAL & ENVIRONMENT
OS SUPPORT
Power Input : DC 12V / 3APower Consumption : 15WAdapter Input : 100 ~ 240 ( 50 / 60Hz ) VACAdapter Output : DC 12V, 3A
Operating Temp. : -10 ~ 50℃Non-Operating Temp. : -20 ~ 80℃Operating Humidity : 10 ~ 90 % Dimensions ( W x H x D ) : 155.2 x 127 x 47.4 mm Mounting : VESA-75/100 compatible ( Optional DIN rail 35mm fixed clamp )
Windows 10 IoT Enterprise Entry
ABB-M400 01. 하드웨어 사양
http://www.tiasolution.net4
SYSTEM
I/O INTERFACE
WIRELESS NETWORK OPTIONAL CONFIGURATION
CPU : Intel Celeron Processor J1900 ( Quad-Core 2M Cache, 2 GHz, up to 2.41GHz )GPU : Onboard VGA( Intel HD Graphics )Memory : 4GB DDR3LStorage : mSATA 64GB* Memory, Storage can be Changed (max 8GB, mSATA 128GB)
Display : 1 x VGALAN : 4 x RJ-45 10/100/1000 Base-TUSB Port : 3 x USB 2.0, 1 x USB 3.0SIM Card : 1 x SIM card socket (internal)
WLAN : IEEE 802.11 b/g/n, Range 50~100m ( ABB-SEN-T200WZ Maximum Connections 30 )ZIGBEE : IEEE802.15.4 ,Maximum Range 120m ( ABB-SEN-T200WZ Maximum Connections 30 )- Support Mini PCIe Type : Bluetooth Module, LTE( 3G ) Module*One network configurations are possible.
ABB-M400 01. 하드웨어 사양
http://www.tiasolution.net 5
POWER REQUIREMENT
MECHANICAL & ENVIRONMENT
OS SUPPORT
Power Input : DC 12V / 3APower Consumption : 10WAdapter Input : 100 ~ 240 ( 50 / 60Hz ) VACAdapter Output : DC 12V, 3A
Operating Temp. : -10 ~ 50℃Non-Operating Temp. : -20 ~ 80℃Operating Humidity : 10 ~ 90 % Dimensions ( W x H x D ) : 155.2 x 127 x 37.4 mm Mounting : VESA-75/100 compatible ( Optional DIN rail 35mm fixed clamp )
Windows 10 IoT Enterprise Entry
ABB-M Series 02. 기본 구성품
http://www.tiasolution.net6
본체
안테나
아답터
DIN Rail Clamp
전원코드
고정볼트
VESA 브라켓
패드
Name
본체 안테나
아답터 DIN Rail Clamp
전원 코드 고정 볼트
VESA 브라켓 패드
ABB-M Series 제품 5dBi 2.4GHz 대역 안테나
입력:100~240 VAC(50/60HZ), 출력: 12VDC / 3A DIN Rail 35mm 장착 가능(fixed clamp )
F형 플러그 코드(유럽 C,F 형 플러그 가능) VESA 브라켓, DIN rail fixed clamp 고정 볼트, 너트
VESA 100 x 100mm, 75 x 75mm 지원 미끄럼 방지용 (바닥면 부착)
NameDescription Description
ABB-M200/M200Z 03. 각부 명칭 및 용도
http://www.tiasolution.net 7
① USB Port
② USB Port
Name
LED
LED
COM Port
COM Port
② USB Port
① USB Port
COM Port
COM Port
HDMI Port
HDMI Port
DC Power Port
DC Power Port
Push Switch
Push Switch
USB Port
USB Port
LAN Port
LAN Port
Audio OUT / Mic IN
Audio OUT / Mic IN
ANT Port
ANT PortANT Port
전원 표시 LED (전원 인가 녹색 발광)
시리얼 연결 단자, RS-232 신호, 9Pin D-Sub Male Type
USB 2.0 지원 연결 단자 (2)
USB 3.0 지원 연결 단자 (2)
시리얼 연결 단자(3), RS-232 신호, 9Pin D-Sub Male Type
비디오 출력 연결 단자 ( HDMI 지원하는 모니터 연결)
아답터 연결 단자
전원 동작 스위치
USB 3.0 지원 연결 단자 (2)
10/100 BASE-T Ethernet 연결 단자(2), RJ45 Type
사운드 출력 및 마이크 입력 연결 단자
WIFI 2.4GHz 5dBi 안테나 연결 단자(M200Z : ZIGBEE 2.4GHz 5dBi 안테나 연결 단자)
NameDescription Description
ABB-M400 03. 각부 명칭 및 용도
http://www.tiasolution.net8
① USB Port
② USB Port
Name
LED
LED
VGA Port
VGA Port
② USB Port
① USB Port
LED
LED
DC Power Port
ANT Port
DC Power Port
Push Switch
Push Switch
LAN Port
LAN Port
ANT PortANT Port
전원 표시 LED (전원 인가 녹색 발광)
비디오 출력 연결단자 (D-Sub 지원 9Pin D-Sub Female Type)
USB 2.0 지원 연결 단자 (2)
USB 2.0 지원 / USB 3.0 지원 연결 단자
동작 표시 LED(노랑색 발광)HDD 동작 표시 LED(빨간색 점열)
아답터 연결 단자
WIFI 2.4GHz 5dBi 안테나 연결 단자
전원 동작 스위치
10/100 BASE-T Ethernet 연결 단자(4), RJ45 Type
NameDescription Description
155.4
7.1 141.2 7.1
47.4
740.4
14.2 10.8 11.7 5 7.7 15.1 13.14.518.2 13.3
0.811.2 15.5 14.2
155.4
127
47.4
155.4
47.4
11.5
29.2
6.7
12 12
30.2 7.2 40.7 26.9 18
61.7
155.4
16.1 16.1123.2
8222.5
22.5
13.2 129 13.2
76.412.2
21.2
35 35
ABB-M200/M200Z 04. 외형 치수
http://www.tiasolution.net 9
단위 : mm
ABB-M400 04. 외형치수
http://www.tiasolution.net10
단위 : mm
-2-3-4 -1
155.4
127
155.4
36.4
729.4
7.1 141.2 7.1
12.9 12.1 12.4 13.2 21.9 21.9 21.9 25 14.2
36.4
155.4
13.2 129 13.2
127
22.5
8222.5
42.7 35 35 42.7
2935
3528
28.6 8.7 33 27.6 23 34.6
36.4
155.4
11.5
186.9
12 12
VESA 브라켓 04. 외형 치수
http://www.tiasolution.net 11
단위 : mm
* VESA 브라켓 장착시 전체 높이는 60mm (M400: 50mm)
35
17.5
9
48
8.1
8.7
1720
11
DIN Rail 35mm Fixed Clamp 04. 외형치수
http://www.tiasolution.net12
단위 : mm
VESA 브라켓 장착 방법 05. VESA 브라켓 장착 방법
http://www.tiasolution.net 13
1. 아래와 같이, 표시된 4곳에 육각 볼트를 오른쪽으로 돌려 조립합니다.
육각볼트
VESA 브라켓 장착 방법 05. VESA 브라켓 장착 방법
http://www.tiasolution.net14
2. 100mm 간격으로 부착할 면에 타공해줍니다. ( VESA 100 x 100mm 규격 )3. VESA 브라켓을 타공해준 구멍에 맞춰주고 둥근 머리나사를 넣고 오른쪽으로 돌려 조립합니다.
브라켓 방향은 움푹한 곳이 앞쪽으로 오도록 부착
둥근머리나사M4.0
VESA 브라켓 장착 방법 05. VESA 브라켓 장착 방법
http://www.tiasolution.net 15
4. ABB 뒷면에 부착한 육각볼트를 화살표 순서대로 브라켓 홈에 끼워 넣어 단단히 고정되도록 합니다.
①
②
DIN rail 35mm Fixed Clamp 장착 방법 06. DIN rail 35mm Fixed Clamp 장착 방법
http://www.tiasolution.net16
1. 아래와 같이, 표시된 4곳에 육각 볼트를 오른쪽으로 돌려 조립합니다.
육각볼트
DIN rail 35mm Fixed Clamp 장착 방법 06. DIN rail 35mm Fixed Clamp 장착 방법
http://www.tiasolution.net 17
2. DIN rail과 브라켓의 빨간색 표시된 구멍에 맞춰준 후 접시 머리 나사와 너트를 조여줍니다.
접시머리나사 M3.0
DIN rail 35mm Fixed clamp
너트 M3.0
브라켓 방향은 움푹한 곳 위로 DIN rail이 오도록 부착
DIN rail 35mm Fixed Clamp 장착 방법 06. DIN rail 35mm Fixed Clamp 장착 방법
http://www.tiasolution.net18
* 조립시 주의사항
DIN rail 35mm Fixed Clamp의 간섭으로 제품 장착에 어려움이 발생될 수 있으니 그림 ①의 화살표 방향으로 최대한 밀어 그림 ②처럼 조립합니다. 그림 ①
그림 ②
DIN rail 35mm Fixed Clamp 장착 방법 06. DIN rail 35mm Fixed Clamp 장착 방법
http://www.tiasolution.net 19
3. 조립된 브라켓을 약간 기울여 DIN rail 상단에 Clamp 홈을 걸듯이 그림의 화살표 방향처럼 밀어 조립합니다.
위쪽 홈에 먼저 끼워 넣은 후 아래쪽을 자연스럽게 딸깍 소리가 날 때까지 밀어줍니다.
①
②
Application 구성도 07. Application 구성도
http://www.tiasolution.net20
Network BUS
BIG DATA
ABB-M Series
MES / ERP / SQL Database
PLC 설비 SPC PC
Q61P
MITSUBISHI
하드웨어 연결 08. 하드웨어 연결
http://www.tiasolution.net 21
1. 전원 연결, 자동 부팅 2. 네트워크 연결
동본 된 아답터를 DC Power Port 연결 후 전원 인가하면, 자동으로 부팅 됩니다.
1분 정도 소요 후 ABB 매니저 프로그램에서 장치 검색하면 노출됩니다.
이더넷 1포트는 고정 IP ( 192.168.100.100 ) 설정 PC 또는 노트북 연결
이더넷 2포트는 유동 IP로써 이더넷 기반의 디바이스 연결 ( PLC, 네트워크, PC, 서버 등 )
①
②
ABB 매니저 프로그램 사용 매뉴얼은 http://tiasolution.net에서 다운로드하실 수 있습니다.
하드웨어 연결 08. 하드웨어 연결
http://www.tiasolution.net22
SIEMENS, FANUC, MITSUBISHI 등 PLC, NC Ethernet 포트에 연결
3. PLC 컨트롤러 연결
Network BUS
Ethernet cable
PLC
직접 연결하기 09. 시작하기
http://www.tiasolution.net 23
1. 직접 연결하기
* 필요 구성품- HDMI 지원 가능한 모니터 (M400 : D-SUB 지원 가능한 모니터)- USB 키보드, 마우스
원격 접속하기 09. 시작하기
http://www.tiasolution.net24
2. 원격 접속 하기
* 필요 구성품- 노트북 또는 원격을 이용할 수 있는 컴퓨터
- 원격 접속은 윈도우 기본 프로그램을 사용하며, 윈도우 Vista/ 7/ 8/ 10을 지원합니다.
이더넷1Default-IP :
192.168.100.100
원격 접속하기 09. 시작하기
http://www.tiasolution.net 25
* ABB M Series 장치로 원격 접속을 위해 아래 사진과 같이 진행합니다.
노트북 접속 환경 설정 (윈도우 10 기준)① 제어판 > 네트워크 및 공유 센터 > 어댑터 설정 변경
원격 접속하기 09. 시작하기
http://www.tiasolution.net26
② 어댑터 설정 변경 > 이더넷 > 속성 > 인터넷 프로토콜 버전 4 속성
원격 접속하기 09. 시작하기
http://www.tiasolution.net 27
③ 다음 IP 주소 사용으로 선택 후 아래 설정으로 기입 한 뒤 확인 버튼을 누릅니다.
IP 주소 : 192.168.100.15
서브넷 마스크 : 255.255.255.0
원격 접속하기 09. 시작하기
http://www.tiasolution.net28
원격 접속 하기 (윈도우 10 기준)① 작업 표시줄 검색 > 검색어 “원격 데스크톱 연결” 또는 “mstsc” > 원격 데스크톱 연결(데스크톱 앱) 선택
원격 접속하기 09. 시작하기
http://www.tiasolution.net 29
② ABB-M Series 제품의 아이피 주소 192.168.100.100 > 연결
컴퓨터 이름 : m200비밀번호 : m200*기본값 : 제품명 / 제품명
품질보증서1. 본 제품은 ‘타이아(주)’에서 판매한 정품임을 밝힙니다.2. 소비자의 정상적인 사용 상태에서 보증기간 이내에 발생한 고장에 대해서는 무상으로 교체, 수리해 드립니다.
보증기간 이내라도 보증서의 유상수리 안내에 해당하는 경우는 서비스 요금이 부과됩니다.3. 수리를 의뢰할 때에는 반드시 이 보증서를 제시 하시기 바랍니다.4. 타이아(주)의 제품 보증은 초기 구매자에게 효력이 발생하며 양도가 불가능 합니다.보증 기간은 구입일로 부터 아래와 같습니다.
본체: 1년 악세서리 : - 전원 어댑터 : 6개월 - 보증제외 : 브라켓, 안테나 설명서 등 * 자세한 사항은 홈페이지를 참고 하시기 바랍니다.
액세서리는 수리가 되지 않습니다. 액세서리는 보증기간 내 이상 시 교체 서비스 되며, 제품 교환 사유에 포함되지 않습니다. 중요한 데이터는 안전한 곳에 백업하시기 바랍니다. 제품에 저장된 데이터 망실은 당사에서 책임지지 않습니다.
보증내용(조건)무상서비스 안내구입일로부터 보증 기간내에 정상적인 사용 상태에서 이상이 발생한 경우에는 무상수리 및 리퍼 제품으로 교환 해드립니다.
유상서비스 안내보증기간이 경과하였거나 보증기간 이내라도 하기의 경우는 유상수리에 해당합니다. 1. 취급 부주의로 발생한 고장 및 파손2. 소비자 임의로 제품을 변경하거나 기계적인 수정을 가하여 발생한 고장3. 사용설명서에서 기재된 사용방법과 주의사항을 지키지 않아 발생한 고장 ( 사용자 과실에 의한 고장 )4. 중고로 구매한 제품의 고장5. 제품의 문제가 아닌, 외부의 전원 장애로 인해 발생한 고장6. 타이아(주) 이외의 사람이 수리하여 제품의 내용을 변경 또는 손상한 경우7. 타이아(주)를 통하여 정식으로 유통되지 않은 제품8. 수해, 벼락 등의 천재지변에 의하여 발생한 고장
품질보증서
주소 : 광주광역시 광산구 신창로 127 신창타워 8층
전화 : 062-973-0782 / FAX. 062-974-0782
이메일 : [email protected]
홈페이지 : http://tiasolution.net
모델명 :
구입일자 : 년 월 일
성명 :
주소 :
S/N :
전화번호 :
품질보증서
CONTENTS
01
02
03
04
05
06
07
08
09
Hardware specifications
Included in the package
Names and uses of parts
Dimensions
How to install VESA bracket
How to install DIN rail 35㎜ fixed clamp
Application diagram
Connecting hardware
Start
ABB-M200 / M200Z
ABB-M200/M200Z
ABB-M200/M200Z
Direct connection
VESA bracket
ABB-M400
ABB-M400
ABB-M400
Remote connection
DIN Rail 35mm Fixed Clamp
34
39
55
38
41
45
48
52
53
http://www.tiasolution.net34
ABB-M200 / M200Z 01. Hardware specifications
SYSTEM
I/O INTERFACE
WIRELESS NETWORK OPTIONAL CONFIGURATION
CPU : Intel Celeron Processor 3215U ( 2M Cache, 1.70GHz, Broadwell ) GPU : Onboard VGA( Intel HD Graphics )Memory : 4GB DDR3LStorage : mSATA 64GB* Memory, Storage can be Changed ( max 8GB, mSATA 128GB )
Display : 2 x HDMIAudio :1 x MIC In, 1 x Speak OutLAN : 2 x RJ-45 10/100 Base-TUSB Port : 2 x USB 2.0, 4 x USB 3.0COM Port : 4 x COMSIM Card : 1 x SIM card socket ( internal )
WLAN : IEEE 802.11 b/g/n, Range 50~100m ( ABB-SEN-T200WZ Maximum Connections 30 )ZIGBEE : IEEE802.15.4 ,Maximum Range 120m ( ABB-SEN-T200WZ Maximum Connections 30 )- Support Mini PCIe Type : Bluetooth Module, LTE( 3G ) Module*Two network configurations are possible.
http://www.tiasolution.net 35
ABB-M200 / M200Z 01. Hardware specifications
POWER REQUIREMENT
MECHANICAL & ENVIRONMENT
OS SUPPORT
Power Input : DC 12V / 3APower Consumption : 15WAdapter Input : 100 ~ 240 ( 50 / 60Hz ) VACAdapter Output : DC 12V, 3A
Operating Temp. : -10 ~ 50℃Non-Operating Temp. : -20 ~ 80℃Operating Humidity : 10 ~ 90 % Dimensions ( W x H x D ) : 155.2 x 127 x 47.4 mm Mounting : VESA-75/100 compatible ( Optional DIN rail 35mm fixed clamp )
Windows 10 IoT Enterprise Entry
ABB-M400 01. Hardware specifications
http://www.tiasolution.net36
SYSTEM
I/O INTERFACE
WIRELESS NETWORK OPTIONAL CONFIGURATION
CPU : Intel Celeron Processor J1900 ( Quad-Core 2M Cache, 2 GHz, up to 2.41GHz )GPU : Onboard VGA( Intel HD Graphics )Memory : 4GB DDR3LStorage : mSATA 64GB* Memory, Storage can be Changed (max 8GB, mSATA 128GB)
Display : 1 x VGALAN : 4 x RJ-45 10/100/1000 Base-TUSB Port : 3 x USB 2.0, 1 x USB 3.0SIM Card : 1 x SIM card socket (internal)
WLAN : IEEE 802.11 b/g/n, Range 50~100m ( ABB-SEN-T200WZ Maximum Connections 30 )ZIGBEE : IEEE802.15.4 ,Maximum Range 120m ( ABB-SEN-T200WZ Maximum Connections 30 )- Support Mini PCIe Type : Bluetooth Module, LTE( 3G ) Module*One network configurations are possible.
ABB-M400 01. Hardware specifications
http://www.tiasolution.net 37
POWER REQUIREMENT
MECHANICAL & ENVIRONMENT
OS SUPPORT
Power Input : DC 12V / 3APower Consumption : 10WAdapter Input : 100 ~ 240 ( 50 / 60Hz ) VACAdapter Output : DC 12V, 3A
Operating Temp. : -10 ~ 50℃Non-Operating Temp. : -20 ~ 80℃Operating Humidity : 10 ~ 90 % Dimensions ( W x H x D ) : 155.2 x 127 x 37.4 mm Mounting : VESA-75/100 compatible ( Optional DIN rail 35mm fixed clamp )
Windows 10 IoT Enterprise Entry
ABB-M Series 02. Basic components
http://www.tiasolution.net38
Main unit
antenna
adapter
DIN Rail Clamp
power cord
fastening bolt
VESA bracket
pad
Name
Main unit Antenna
Adapter DIN Rail Clamp
Power cord Fasteners
VESA bracket Pad
product in ABB-M series 5dBi 2.4GHz Antenna
Input:100~240 VAC(50/60HZ), Output: 12VDC / 3A compatible with DIN Rail 35mm (fixed clamp).
F-type plug cord (compatible with European C & F-type plug).
VESA bracket, bolt and nut for fastening DIN rail fixed clamp
VESA 100 x 100mm, 75 x 75mm supported.
non-slip (attached to the floor).
NameDescription Description
ABB-M200/M200Z 03. Names and uses of parts
http://www.tiasolution.net 39
① USB Port
② USB Port
Name
LED
LED
COM Port
COM Port
② USB Port
① USB Port
COM Port
COM Port
HDMI Port
HDMI Port
DC Power Port
DC Power Port
Push Switch
Push Switch
USB Port
USB Port
LAN Port
LAN Port
Audio OUT / Mic IN
Audio OUT / Mic IN
ANT Port
ANT PortANT Port
LED for power-on (green light when power is provided).
Serial port, RS-232 signal, 9-pin D-Sub male type.
USB 3.0 port (2)
USB 3.0 port (2)
Serial port (3), RS-232 signal, 9-pin D-sub male type.
Video output port (for HDMI monitor).
Adapter port.
Power-on switch.
USB 3.0 port (2).
10/100 BASE-T Ethernet port (2), for RJ45.
Sound output and microphone input ports.
Wi-Fi 2.4GHz 5dBi antenna port.(M200Z: ZIGBEE 2.4GHz 5dBi antenna port).
NameDescription Description
ABB-M400 03. Names and uses of parts
http://www.tiasolution.net40
① USB Port
② USB Port
Name
LED
LED
VGA Port
VGA Port
② USB Port
① USB Port
LED
LED
DC Power Port
ANT Port
DC Power Port
Push Switch
Push Switch
LAN Port
LAN Port
ANT PortANT Port
LED for power-on (green light when power is provided).
Video output port.(D-Sub compatible 9-pin D-Sub female type)
USB 2.0 port.
USB 2.0/USB 3.0 port.
Operation indicator LED (light in yellow).HDD operation indicator LED (light in red).
Adapter port.
Wi-Fi 2.4GHz 5dBi antenna port.
Power-on switch.
10/100 BASE-T Ethernet port (2), for RJ45.
NameDescription Description
155.4
7.1 141.2 7.1
47.4
740.4
14.2 10.8 11.7 5 7.7 15.1 13.14.518.2 13.3
0.811.2 15.5 14.2
155.4
127
47.4
155.4
47.4
11.5
29.2
6.7
12 12
30.2 7.2 40.7 26.9 18
61.7
155.4
16.1 16.1123.2
8222.5
22.5
13.2 129 13.2
76.412.2
21.2
35 35
ABB-M200/M200Z 04. Dimensions
http://www.tiasolution.net 41
Unit : mm
ABB-M400 04. Dimensions
http://www.tiasolution.net42
Unit : mm
-2-3-4 -1
155.4
127
155.4
36.4
729.4
7.1 141.2 7.1
12.9 12.1 12.4 13.2 21.9 21.9 21.9 25 14.2
36.4
155.4
13.2 129 13.2
127
22.5
8222.5
42.7 35 35 42.7
2935
3528
28.6 8.7 33 27.6 23 34.6
36.4
155.4
11.5
186.9
12 12
VESA bracket 04. Dimensions
http://www.tiasolution.net 43
Unit : mm
* With VESA bracket installed, total height is 60㎜ (M400: 50㎜).
35
17.5
9
48
8.1
8.7
1720
11
DIN Rail 35mm Fixed Clamp 04. Dimensions
http://www.tiasolution.net44
Unit : mm
How to install VESA bracket 05. How to install VESA bracket
http://www.tiasolution.net 45
1. As shown below, attach hex bolts to the four marked positions by turning them to clockwise.
Hex bolt
How to install VESA bracket 05. How to install VESA bracket
http://www.tiasolution.net46
2. Punch holes with an interval of 100㎜ on the surface to attach it to (VESA 100 x 100㎜). 3. Put the VESA bracket to the holes created and combine it by inserting the slotted round head screws and turning them clockwise.
when attaching the bracket, keep the concave side to the front.
lotted round head screwM4.0
How to install VESA bracket 05. How to install VESA bracket
http://www.tiasolution.net 47
4. Insert one after another of the hex bolts attached to the back of ABB into bracket holes and then fasten them tight.
①
②
How to install DIN rail 35㎜ fixed clamp 06. How to install DIN rail 35㎜ fixed clamp
http://www.tiasolution.net48
1. As shown below, attach hex bolts to the four marked positions by turning them to clockwise.
Hex bolt
How to install DIN rail 35㎜ fixed clamp 06. How to install DIN rail 35㎜ fixed clamp
http://www.tiasolution.net 49
2. Align DIN rail with the red-marked holes on the bracket and tighten the dish head screw and nut.
Dish head screw M3.0
DIN rail 35mm Fixed clamp
nut M3.0
when attaching the bracket, keep the concave side to the front.
How to install DIN rail 35㎜ fixed clamp 06. How to install DIN rail 35㎜ fixed clamp
http://www.tiasolution.net50
* Precautions for assembly
As interference from DIN rail 35㎜ fixed clamp may cause difficulty in installing the product, push it as far as possible in the direction of the arrow at ① and assemble it as shown in Image ②.
image ①
image ②
How to install DIN rail 35㎜ fixed clamp 06. How to install DIN rail 35㎜ fixed clamp
http://www.tiasolution.net 51
3. Slant the assembled bracket a little bit and push it in the direction of the arrow shown in the image as if hooking the clamp pit with the top portion of the DIN rail.
After inserting it into the upper pit, push the lower part until it clicks.
①
②
Application diagram 07. Application diagram
http://www.tiasolution.net52
Network BUS
BIG DATA
ABB-M Series
MES / ERP / SQL Database
PLC equipment SPC PC
Q61P
MITSUBISHI
Connecting hardware 08. Connecting hardware
http://www.tiasolution.net 53
1. Power on and auto-booting 2. Network connection
When the included adapter is connected to DC power port and power is supplied, it boots automatically.
Wait about a minute and search the device in ABB Energy Manager software, and it will show.
Ethernet port 1 should be connected to a desktop or laptop with a fixed IP (192.168.100.100 ).
Ethernet port 2, which has a dynamic IP, should be connected to Ethernet-based devices.(such as PLC, network, PC, and server)
①
②
The manual for ABB Energy Manager software can be downloaded from http://tiasolution.net.
Connecting hardware 08. Connecting hardware
http://www.tiasolution.net54
Connecting PLC & NC of Siemens, FANUC, Mitsubishi etc. to Ethernet port.
3. Connecting PLC controller
Network BUS
Ethernet cable
PLC
Direct connection 09. Start
http://www.tiasolution.net 55
1. Direct connection
* Required components- HDMI monitor (M400: D-Sub monitor)- USB keyboard & mouse
Remote connection 09. Start
http://www.tiasolution.net56
2. Remote connection
* Required components- Laptop or remotely accessible desktop.
- Remote connection uses the one in Windows Accessories and supports Windows Vista, 7, 8, and 10.
ETHERNET1Default-IP :
192.168.100.100
Remote connection 09. Start
http://www.tiasolution.net 57
* Using a device from ABB M series for remote connection, proceed as follows.
Setting laptop connection (for Windows 10)① Control Panel > Network & Sharing Center > Change Adapter Settings
Remote connection 09. Start
http://www.tiasolution.net58
② Change Adapter Settings > Ethernet > Properties > Internet Protocol V4 Properties.
Remote connection 09. Start
http://www.tiasolution.net 59
③ Select the IP address below, enter the following settings and click OK.
IP address: 192.168.100.15
Subnet mask: 255.255.255.0
Remote connection 09. Start
http://www.tiasolution.net60
Remote connection (for Windows 10)① Search in task bar > Search word “Connect remote desktop” or “mstsc” >remote desktop.
Remote connection 09. Start
http://www.tiasolution.net 61
② With a product from ABB M series at IP address: 192.168.100.100 > connect
Computer name: m200Password: m200*Default value: product name / product name
Warranty Certificate1. The is an authentic product sold by TIA Co., Ltd. 2. All our products that have incurred errors within the warranty period are eligible for free replacement or repairs,
provided the customer uses it in a normal manner. Even if a product remains under warranty, a service fee is charged for those issues for which paid services are applicable as announced. A customer who wants a repair for a product must submit this Warranty Certificate.3. Warranty for TIA’s products are applicable only for their first buyer and cannot be transferred to anyone else.4. Warranty period is as follows. Main unit : 1 year Accessories : - power adapter : 6 months - Exceptions for warranty: Bracket, antenna etc.
* Please check the company’s website for more information.
For problems within the warranty period, accessories shall be replaced, but they are not eligible for the replacement of the whole product. and keep it in a safe location. The company shall not be responsible for the loss of any data saved in the product.
Warranty (Terms)Guide to free servicesAll our products that have incurred errors within the warranty period are eligible for free replacement or repairs, provided the customer uses it in a normal manner.
Guide to paid servicesFees apply when the warranty has expired or in the following cases even if a product remains under warranty. 1. Trouble or damage from negligence.2. Trouble caused by unauthorized product alteration or mechanical modification by customer.3. Trouble caused by incompliance with user instructions and precautions included in User Manual (caused by user’s
fault).4. Trouble with a product purchased as a used one. 5. Troubles caused, not by issues within a product, but by problems with external power supply.6. When a product has been modified or damaged by a repair person, not deployed by TIA Co., Ltd.7. A product which was not supplied by the official distribution system of TIA Co., Ltd.8. Trouble caused by force majeure such as flooding or lightning.
Warranty Certificate
ADDRESS : 8 Sinchang Tower 127, Sinchang-ro, Gwangsan-gu, Gwang-ju, KOREA, 62249
TEL : +82-62-973-0782 / FAX. +82-62-974-0782
E-mail : [email protected]
HOMEPAGE : http://tiasolution.net
customer :
purchased date : mm dd yyyy
name :
address :
S/N :
phone number :
Warranty Certificate
타이아(주)광주광역시 광산구 신창로 127 신창타워 8층 TEL. 062-973-0782 FAX. [email protected] http://tiasolution.net / http://activetiaplant.com / http://industry4mall.com