AccuPoint

Embed Size (px)

Citation preview

  • 8/14/2019 AccuPoint

    1/2

    78 Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 Fax: 517/372-2006 www.neogen.com

    Food Safety Online Orderingwww.neogen.com/foodsafetyorder.htmSanitation

    AccuPoint

    Sanitation Monitoring System

    Intended Use

    Neogens AccuPoint ATP Sanitation Monitoring System is a lightweight,handheld system that validates the effectiveness of a sanitation programby detecting food residues and microorganisms present on surfaces and inliquids. The system utilizes easy-to-use AccuPoint samplers, which auto-matically mix prepared reagents to quickly generate results.

    The Test

    The AccuPoint system utilizes adenosine triphosphate (ATP) biolumi-nescence to determine the cleanliness of test samples. ATP is a chemicalcompound found in all living cells, including bacteria, food debris, yeastand mold. Bioluminescence is a chemical reaction that produces light.

    ATP bioluminescence occurs when ATP from a sample comes intocontact with luciferase, an enzyme found in fireflies, and luciferin, asubstrate. The amount of light emitted in this reaction is proportional

    to the amount of ATP detected in a sample.

    After a sample is taken the sampler is pressed into its cartridge in themonitor, breaking its seals and initiating the mixing of reagents. Thecartridge contains a buffering solution, which flushes the ATP ontoa pad containing the reagents. The reaction takes place within thecartridge and a detector measures the amount of light produced. Thereading is displayed on the LCD display in relative light units (RLU).

    According to preset limits, an icon is displayed indicating a pass, mar-ginal or fail result. These limits are defined by the operator or by usingthe system presets.

    Consistently Accurate

    The samplers vertical sampling technique increases downwardpressure on the surface. This helps penetrate surface crevasses, andbreak-up existing biofilms to uncover previously protected organisms.

    The sponge will reabsorb the liquid, with any present organic matteror bacteria, for consistently accurate results.

    Sampler extender (optional)

    Sampler

    Sample Pad

    Cartridge

    Buffer

    Luciferaseand

    Luciferin

    Three samplers engineered for precise sampling in each

    unique applicationflat surfaces, water samples and

    tight spaces such as small orifices and channels

    http://www.neogen.com/foodsafetyorder.htmhttp://www.neogen.com/foodsafetyorder.htmhttp://www.neogen.com/foodsafetyorder.htm
  • 8/14/2019 AccuPoint

    2/2

    Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 Fax: 517/372-2006 www.neogen.com

    Food Safety Online Orderiwww.neogen.com/foodsafetyorderSanitation

    Results

    AccuPoint

    Sanitation Monitoring System

    Ordering Information

    Prod.# Product description

    9600 AccuPoint Sanitation Monitoring System - Includes monitor

    NiMH battery pack, Docking station with power supply data

    cable, DataManager Software and Users Guide

    9605 AccuPoint ATP Surface Samplers (100)

    9606 AccuPoint Water Samplers (100)

    9607 AccuPoint Access Samplers (100)

    9610 NiMH Battery Replacement pack

    9611 Sampler extender

    9612 AccuPoint Cleaning Kit (5 swabs)

    9613 AccuPoint Stand-up Holster

    9615 AccuPoint Docking Station

    9616 AccuPoint Communications Cable

    9617 AccuPoint DataManager Software

    9618 Hawking Technologies USB Serial Converter

    9619 ATP Standards Kit

    2. Insert sampler into cartridge to first stop

    3. Insert cartridge into device and

    fully depress sampler. Close unit

    door and read results.

    1. Sample surface or water

    The Procedure

    AccuPoint comes with Data Managersoftware that allows customers to:upload results to a PC, set pass/caution/fail levels, create and print

    trend analysis graphs, export data tospreadsheets, and keep a record of sanitation effectiveness to veSSOPs. Results can be presented in a clear chart format showingactual measurement in color coded green (pass), yellow (cautand red (fail) for extra clarity. Accumulated results can be grapusing bar or pie charts, over a variety of criteria, for clear pictof sanitation testing results and trends.

    After the countdown, the data reading is displayed. Easy to intericons indicate a pass, marginal or fail result. Results can be recoror using AccuPoints docking station, simply uploaded to a PC

    easy data analysis.

    Use the Access sampler

    for tight spaces