Upload
lamkiet
View
219
Download
0
Embed Size (px)
Citation preview
ACCU-STEAM GAS GRIDDLE
OWNERS MANUAL IMPORTANT WARRANTY INFORMATION: For product warranty activation, the ACCU-STEAM Griddle Start-Up Form and the Product Registration Form must be submitted to AccuTemp Products, Inc. after installation of the appliance. ACCU-STEAM Griddle Start-Up Form Product Registration Form
AT2T-3238-1 Rev. B AccuTemp Products, Inc. 8415 North Clinton Park Fort Wayne, IN 46825 800-210-5907 www.accutemp.net
dpeaksTextBoxRev C
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page i
IMPORTANT FOR YOUR SAFETYThese installation instructions have been prepared for qualified gas equipment
installation personnel, who should perform the initial field start-up and complete theequipment adjustments described in this manual.
The safety instructions listed below on this page should be posted in a prominentlocation as a reminder of safe practices as well as recommended actions to follow in theevent of an equipment or facility utility issue.
Retain this Manual for future reference
WARNING
In the event a gas odor is detected, shut down all appliances at the maingas shut-off valve and contact the local gas company or gas supplier for
service.
WARNING
In the event of a power failure, do not attempt to operate this appliance.
WARNING
Do not store or use gasoline or other flammable vapors or liquids in thevicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service or maintenance cancause property damage, injury or death. Read the installation, operating,and maintenance instructions thoroughly before installing or servicing this
equipment.
dpeaksRectangle
AT2T-3238-1 Rev. c ACCU-STEAM TM GAS GRIDDLE OWNERS MANUAL Page i
DOCUMENT HISTORY
Current revision: Prior revision: NoneDate: 2/28/06 Date: NoneChangeInitial release.
Current revision: A Prior revision: Date: 3/14/06 Date: 2/28/06
Change
Page 4 Added unpacking information.Page 5 Added tipping warning.Page 8 Added reference to warranty cardPage 10 Added second supplier for suggested cleaning products.Page 19 Added Pilot Burner Assembly service parts drawing.Page 25 Revised and moved Start-Up Form.
Current revision: B Prior revision: ADate: 6/30/06 Date: 3/14/06
ChangePage 4 Added warning information.Page 7 Modified Electrical Requirements section.Pages 8 & 9 Modified Gas Connection section.Page 10 Revised reference for Product Registration Form.Page 12 Added second supplier for suggested cleaning products.Page 16 Added Orifice Table.Page 22 Added Pilot Burner Assembly service parts drawing.FS3803-0607 Revised and moved Start-Up Form to the end of this manual.
Current revision: C Prior revision: BDate: 7/11/08 Date: 6/30/06
Change
Page ii - Revised Table of Contents to Match Document
Page 16 Added Gas Appliance STD Conversion Kit Drawing
Page 27 Added High Limit Overtemp Assembly Parts Drawing
FS 3805-0804 Added Preventive Maintenance Recommendation Form
AT2T-3238-1 Rev. B ACCU-STEAM TM GAS GRIDDLE OWNERS MANUAL Page ii
TABLE OF CONTENTS
DOCUMENT HISTORY i
TABLE OF CONTENTS ii
SAFETY WARNINGS 1 2
THEORY OF OPERATION 3
INSTALLATION 4 10
OPERATION 11 12
SERVICE AND TROUBLESHOOTING 13 15
Gas Conversion Kit 16GAS GRIDDLE ORIFICE REFERENCE TABLE FOR ALITITUDEAND BTU CONTENT 17
GAS GRIDDLE ASSEMBLY SERVICE PARTS 18 19
COMBUSTION CHAMBER ASSEMBLY SERVICE PARTS 20 22
PILOT BURNER ASSEMBLY SERVICE PARTS 23
GAS CONTROL VALVE ASSEMBLY SERVICE PARTS 24
CONTROL PANEL SERVICE PARTS 25 26
HIGH LIMIT OVERTEMP ASSEMBLY 27
GAS GRIDDLE SCHEMATIC 28
WARRANTY 29
ACCU-STEAM GAS GRIDDLE START-UP FORM FS3803-0607ACCU-STEAM GAS GRIDDLE PREVENTIVE MAINTENANCEFORM FS3805-0804
dpeaksTextBoxC
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 1/29
SAFETY WARNINGS
SYMBOL DEFINITIONSSymbols are used to attract your attention to possible dangers. They are only effectiveif the operator uses proper accident prevention measures. Some of the symbols areboxed text, while other maybe just picture icons. Please give this information therespect they deserve for safe operation.
WARNING TEXT BOXESBelow are definitions of the warning text boxes:
DANGER
Indicates an imminently hazardous situation which, if not avoided, willresult in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided, couldresult in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, couldresult in minor or moderate injury.
NOTE
Advises reader of information or instructions vital to the operation ormaintenance of the equipment.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 2/29
SAFETY WARNINGS (cont.)
SYMBOL ICONSBelow are definitions of symbol icons used in this manual:
ALERT Notifies the reader of an important message/warning, usually a safety relatedmessage.
INFORMATION Notifies the reader of important information that may or may not besafety-related.
EARTH GROUND
DANGEROUS VOLTAGE
CAUTION, HOT SURFACE
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 3/29
THEORY OF OPERATION
INTRODUCTIONThe ACCU-STEAMgriddle is constructed and uses technology like no other
griddle in the world. The diagram below is a cross-sectional view of the griddle. Thegriddle cooking surface is the top of a chamber in which we have produced a uniqueenvironment. Welded stainless steel reinforcement studs connect the chamber top tothe chamber bottom. The perimeter joints are all robotically welded and produce avessel that is airtight, which is verified using a helium mass spectrometer. Thechamber is filled half full with distilled water. The remaining air is removed and thechamber is welded shut. At this point, the chamber becomes a hermetically sealedvessel, never to be opened again. The griddle steam chamber requires no wateror maintenance. A thermowell for a thermocouple to sense temperature and athermowell for the overtemp safety shutdown system are also welded into the griddlesteam chamber.
At temperatures below 212F (100C), the chamber is actually in a vacuum, similarto that of a canning jar. At temperatures above 212F (100C), the chamber operatesunder pressure. Located between the water and the bottom of the cooking surface isthe best heat transfer medium steam, the most effective way to transfer heat. Thethermocouple senses the temperature of the steam and reports this data to thethermostat, which ignites the burners. This system maintains the griddle cookingsurface temperatures to within 3F (1.7C) over the entire cooking surface andprovides a near instant temperature recovery, even in the same spot on the griddle,when turning food in place.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 4/29
INSTALLATION
This installation must conform with local codes, or in the absence of local codes, withNational Fuel Gas Code, ANSA/NFPA 54, or the Natural Gas and PropaneInstallation Code, CSA B149.1, as applicable.
The appliance and its individual shutoff must be disconnected from thegas supply piping system during any pressure testing of that system at testpressures in excess of psi (3.5kPa)
The appliance must be isolated from the gas supply piping system byclosing its individual manual shut off valve during any testing of the gassupply piping system at a test pressure equal to or less than psi (3.5kPa).LOCATION AND PLACEMENT
The AccuTemp ACCU-STEAMgas griddle can be placed on a commercial kitchencounter-top or AccuTemp griddle stand.
The operating temperature ranges from 200- 400F (93- 204C). Since thesetemperatures can also be found on surfaces around the perimeter of the griddle, careshould be given not to install griddle next to or against, objects or surfaces with a lowmelting or flash point. See Figure 1 for clearance restrictions.
Figure 1
WARNING
Only qualified service technicians/electricians should perform theinstallation to ensure that all electrical and safety requirements are met
and that all wiring is performed in accordance with all national, state andlocal electrical codes.
CAUTION
Temperatures on and around the griddle cooking surface could causesevere burns.
CLEARANCE RESTRICTIONS
COMBUSTIBLE NON-COMBUSTIBLESIDES 1 0REAR 2 0
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 5/29
INSTALLATION (cont.)
Provisions should be incorporated in the design of the kitchen, to ensure anadequate supply of fresh air for proper combustion and ventilation. When installing,never enclose the bottom of the unit with a raised curb or any other construction thatwould obstruct the flow of air into the unit.
UNPACKINGThis appliance was carefully inspected before shipment from the factory. The
transportation company assumes full responsibility for safe delivery to the customeruntil customer acceptance of this packaged appliance.GRIDDLE LIFTING
Griddles are heavy enough to require additional manpower or powered assistancewhen installing or moving the griddle.
LEVELINGThe griddle must be installed in a level condition. An out-of-level condition may
cause damage to the griddle and damage of this type is not covered by the limitedwarranty. Use a spirit level resting on the griddle surface to ensure it is level front-to-back and left-to-right.
If this is a counter-top installation, the griddle must be set and leveledusing the adjusters on the legs before installing the (4) rubber foot tipsprovided with the griddle. The installation of the 4 rubber tips will keep the griddlefrom sliding on the counter-top under normal use.If your griddle is attached to an AccuTemp stand with casters, ensure that the floorsurface is level and place the two locking casters to the on position.
STAND INSTALLATIONAll griddle installations utilizing an AccuTemp stand with casters, shall be made with
a connector that complies with the Standard for Connectors for Movable GasAppliances, ANSI Z21.69 or CAN/CGA 6.16 and a quick disconnect device thatcomplies with the Standard for Quick Disconnect Devices for Use With Gas Fuel,ANSI Z21.41 or CAN 1-6.9.
CAUTION
This appliance is heavy. For safe handling, the installer should obtain helpas needed or employ appropriate material handling equipment to remove
the appliance from the skid and move into its final destination.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 6/29
INSTALLATION (cont.)
Adequate means must be provided to limit the movement of the stand withoutdepending on the connector and the quick-disconnect device or its associated piping tolimit movement. The restraining device shall be mounted to the rear leg supports ofthe stand.
IN-FIELD MODIFICATIONSThis griddle has a totally unique design and is constructed unlike any
other griddle on the market today. Any modification may permanentlydamage the griddle and void the warranty.
ELECTRICAL SUPPLYThe ACCU-STEAMgriddle has been designed, manufactured and tested to meet
or exceed the demanding standards of safety set forth by Underwriters Laboratories,Inc. To ensure that this high level of safety is maintained in your installation, it isimportant that you read and understand the following information before attempting toplug in your griddle.
WARNING
When the griddle is mounted on a stand with casters, the floor surfacemust be level. If the floor is not level, the griddle and stand may become
unstable, such that tipping may occur, causing serious injury.
WARNING
Any in-field modification made without written authorization fromAccuTemp will void all warranties.
DANGER
Any in-field modifications that bypass the built-safety features of thisproduct will result in death or serious injury.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 5/29
INSTALLATION (cont.)
Provisions should be incorporated in the design of the kitchen, to ensure anadequate supply of fresh air for proper combustion and ventilation. When installing,never enclose the bottom of the unit with a raised curb or any other construction thatwould obstruct the flow of air into the unit.
UNPACKINGThis appliance was carefully inspected before shipment from the factory. The
transportation company assumes full responsibility for safe delivery to the customeruntil customer acceptance of this packaged appliance.GRIDDLE LIFTING
Griddles are heavy enough to require additional manpower or powered assistancewhen installing or moving the griddle.
LEVELINGThe griddle must be installed in a level condition. An out-of-level condition may
cause damage to the griddle and damage of this type is not covered by the limitedwarranty. Use a spirit level resting on the griddle surface to ensure it is level front-to-back and left-to-right.
If this is a counter-top installation, the griddle must be set and leveledusing the adjusters on the legs before installing the (4) rubber foot tipsprovided with the griddle. The installation of the 4 rubber tips will keep the griddlefrom sliding on the counter-top under normal use.If your griddle is attached to an AccuTemp stand with casters, ensure that the floorsurface is level and place the two locking casters to the on position.
STAND INSTALLATIONAll griddle installations utilizing an AccuTemp stand with casters, shall be made with
a connector that complies with the Standard for Connectors for Movable GasAppliances, ANSI Z21.69 or CAN/CGA 6.16 and a quick disconnect device thatcomplies with the Standard for Quick Disconnect Devices for Use With Gas Fuel,ANSI Z21.41 or CAN 1-6.9.
CAUTION
This appliance is heavy. For safe handling, the installer should obtain helpas needed or employ appropriate material handling equipment to remove
the appliance from the skid and move into its final destination.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 7/29
INSTALLATION (cont.)
ELECTRICAL REQUIREMENTSThe electrical voltage requirement is listed on the data plate that is located on the
front control panel. All standard AccuTemp gas griddles are supplied with power cordand plug that must be connected to a standard 15 A (120 V) or 20 A (208 240 V)grounded receptacle. Make sure that the voltage at your supply receptacle is within 10 % of the voltage listed on the griddle data plate. Connection to any other voltagenot identified on the data plate may cause damage to components in the griddle anddamage of this type is not covered under the warranty.
Ensure that the position of the wall receptacle is not in a high heat zone. Electricalconnections made in a high heat zone, such as just above, below or beside the griddleexhaust flue, will cause plug and cord failures that will not be covered under thewarranty. It is recommended that the wall receptacle be positioned as low as State andlocal codes will allow.
GROUNDING INSTRUCTIONSGrounding provides a path for electric current to reduce the risk of shock. This
product is equipped with a power cord having a grounding conductor and a groundingplug. The plug must be plugged into a receptacle that is properly installed andgrounded in accordance with all National, State and local electrical codes, or in theabsence of local electrical codes with National Electric Code, ANSI/NFPA 70, orthe Canadian Code, CSA C22.2 as applicable. Under no circumstances shall theplugs round grounding prong be cut or bent to fit a receptacle other than the onespecified. A two-prong adaptor must never be used.
WARNING
This appliance must be properly grounded, in accordance with all National,State and local electrical codes.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 8/29
INSTALLATION
GAS CONNECTIONThis griddle has been manufactured for use with the type of gas indicated on the
data plate. Contact AccuTemp Products Technical & Customer Support Department ifyour gas supply does not match the gas indicated on the griddle data plate.
All gas connectors must be in accordance with local codes and must comply with thelatest edition of the National Fuel Federal Gas Codes, ANSI Z223.1.
This griddle should have a separate gas shutoff valve (not supplied) installed in thegas supply line. Use a or larger diameter gas supply line to connect this griddle tothe facility supply manifold to ensure a sufficient volume of gas. The facility supplyregulator and manifold must be sized according to the load of all appliances connectedto it. If other gas appliances are connected to the supply manifold, their gas load mustbe added to the calculations for properly sizing the supply manifold and regulator.Note: Flexible residential appliance connection hoses are not suitable for this applianceand may void the warranty.
If your griddle installation location is at an altitude of 4000 feet or higher, theorifices must be changed to allow appropriate gas supply to the burners. An altitudechart for natural and propane gases is located after the Service and Troubleshootingsection of this manual. Please contact the AccuTemp Technical & Customer SupportDepartment for assistance if the orifices need to be changed due to altitude.
This griddle has been supplied with internal gas regulators that have been factoryset for the gas type and pressures listed on the griddle data plate. An external regulatorshould not be used unless the supply gas pressure is more than 0.5 psig. The externalregulator must be rated at least 125% of the griddle BTUH rate at the pressure higherthan the rated regulated pressure (for example, a 36 gas griddle is rated at 70,000BTUH at 5 W.C. for natural gas).
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 9/29
INSTALLATION (cont.)
Figure 2
Adjust the regulator(s) as needed to comply with the pressures indicated on thegriddle orifice and pressure specification label. See Figure 2 for the orifice and pressurespecification data.
Figure 3
The system gas supply pressures for the main and pilot burners should be verifiedwith a manometer while the appliance is operating in a maximum load condition. A1/8 NPT tap is provided in the front of the main regulator valve, to measure the mainburner supply pressure. A second NPT tap is located just to the right of the pilotburner regulator for measurement of the pilot burner supply pressure. See Figure 3 forthe pressure tap locations. Use a pipe joint compound or sealant designed for use withliquid petroleum gas when replacing the 1/8 NPT plug or the NPT plug.NOTE: Do not use an excessive amount of sealant, in order to prevent potentialobstruction of orifices and control valves.
1/8 NPT
1/4 NPT
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 10/29
INSTALLATION (cont.)
A colored sheet copy of the ACCU-STEAM Griddle Start-Up Form and the griddleProduct Registration Form were enclosed in the gas griddle from the factory. Both ofthese documents must be completed and submitted to the AccuTemp Technical &Customer Support Department for the warranty to be activated. The ACCU-STEAMGriddle Start-Up Form can be faxed or mailed to AccuTemp. The Product RegistrationForm must be mailed to AccuTemp. A copy of the ACCU-STEAM Griddle Start-UpForm is attached at the end of this manual for reference or use as the master form tobe completed during installation and later submitted to AccuTemp. It is recommendedthat a copy of the completed ACCU-STEAM Griddle Start-Up Form be attached to thismanual for future reference.
If any of these installation requirements are not completely understood or you areunsure as to whether your supply receptacle is the correct voltage, type or is properlygrounded or that you have the correct gas type and/or delivery pressure, call AccuTempTechnical & Customer Support Department at 1-800-480-0415 or +1-260-469-0415,7:00am 7:00pm Monday thru Sunday, before attempting to start the griddle.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 11/29
OPERATION
SEASONINGIt is recommended that you clean your ACCU-STEAMgriddle thoroughly before
turning your unit on. To clean the griddle surface, just simply wash the cooking surfacedown with a solution of mild soap and water, and then rinse thoroughly with cleanwater.
Once the cooking surface has been cleaned, set the thermostat to 200F (93C),turn the griddle power switch to the On position and allow the griddle cooking surfaceto heat for 10 minutes. Using a high temperature oil, such as Pan and GrillShortening Whirl or equivalent, pour enough to cover the entire griddlesurface. Do not use standard vegetable oil to season the griddle cookingsurface. It may cause food to stick and result in improperly cooked food. Work thisseasoning oil into the griddle surface with a regular heavy-duty scrub pad for about 5minutes, making sure that you scrub the seasoning oil over the entire griddle-cookingsurface. After the entire griddle surface has been scrubbed with seasoning oil for 5minutes, simply wipe or squeegee off excess oil from griddle surface. Your griddle isnow ready to use!
If you use chemicals to clean your griddle periodically or on a schedule,you may need to repeat this process after the use of chemicals.
PREHEATINGTurn On switch to the On position and set the thermostat to the desired
temperature. The griddle will increase its surface temperature at an average rate of 15F (8C) per minute. It takes approximately 22 minutes to raise the griddle from roomtemperature to its maximum temperature of 400 F (204C). The griddle will bepreheated when the Heat light starts to cycle on and off. Please use caution astemperatures on and around the griddle cooking surface could cause severeburns.
COOKINGBegin cooking only after the griddle has been preheated to the desired temperature.
Please note these facts: You can cook all the way to the edges of the griddle surface because the
temperature does not very across the entire cooking surface. You can turn the product to the same spot because the griddle has near
instant heat recovery. It will always cook the same, regardless of product load or surface coverage.
Accurate Cooking TemperaturesBecause of the inaccurate surface temperatures and long recovery times common
with other griddles. It is doubtful you were cooking at the set temperature or thetemperature you wanted. Adjust the temperature on your ACCU-STEAMgriddle and it
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 12/29
OPERATION (cont.)
wont change or vary by the location on the griddle surface. There are no hot or coldzones.
Heat LampIt is normal for the heat light to cycle on and off. This light indicates when the
main burners are energized. You will soon notice how little they are energized tomaintain perfect surface temperatures on your griddle.
Grease PanUse caution when emptying the grease pan. The contents in this pan could cause
severe burns. The pan should be checked periodically and emptied as necessary toprevent an overflow or dangerous condition.
DAILY CLEANINGCleaning during the work shift can be performed with a sharp scraper. When heavy
cleaning at the end of a shift or periodically as needed, the following is recommended: Turn the griddle off and allow it to cool to between 220F and 240F
(104F and 116C). Use water, ice and/or griddle cleaner as needed. Forexample, the 3M Scotch-BriteQuick Clean Griddle System or Ecolab GreaseExpress High-Temp Grill Cleaner System are commercially-availableproducts for cleaning griddles. Clean-up is very easy using these productswith the quick clean liquid, water, ice or combinations of these liquids.
If a griddle with grease on the cooking surface is cleaned at a hightemperature using water or ice, the grease may splatter and causeskin burns. Be very cautious!
Do not use a griddle stone or brick to clean the griddle. Do not use a water-jet to clean the griddle. Dry all surfaces.
NOTE
Never leave a chlorine sanitizer in contact with the stainless steel longerthan 10 minutes. Longer contact can cause corrosion and permanently
damage the griddle.
CAUTION
The grease can contents could cause severe burns. Slowly remove thegrease can from the griddle to avoid spilling the contents.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 13/29
SERVICE AND TROUBLESHOOTING
NO USER-SERVICEABLE PARTSThere are no user-serviceable parts. AccuTemp-authorized service personnel should
complete any servicing. Service performed by unauthorized personnel will void thewarranty.
NOTE
An AccuTemp Products, Inc. Technical & Customer Support Technician isavailable Monday thru Sunday, 7:00am to 7:00pm EST at
1-800-480-0415 or +1-260-469-3040.
WARNING
Any in-field modification made without written authorization fromAccuTemp will void the warranty.
WARNING
Only qualified service technicians/electricians should perform theinstallation to ensure that all electrical and safety requirements are met
and that all wiring is performed in accordance with all national, state andlocal electrical codes.
DANGER
Any in-field modifications that bypass the built-safety features of thisproduct will result in death or serious injury.
WARNING
There are no user-serviceable parts. To prevent electrical shock do notopen access panel covers.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 14/29
SERVICE AND TROUBLESHOOTING (cont.)
GENERAL SERVICE INFORMATION
BASIC TROUBLESHOOTING
Griddle will not turn on Make sure the griddle is plugged in and the ON/OFF switch is in the ON
position. The power indicator light must be On when the ON/OFF switch is in the
ON position. Check for a facility circuit breaker (or fuse) supplying the unit. Check to see that the external gas shutoff valve is open. Call the AccuTemp Products, Inc Technical & Customer Support Department
at +1-260-469-3040 or toll free at 1-800-480-0415.
WARNING
Use of any replacement parts other than those supplied by AccuTempProducts, Inc. can cause injury to the operator or damage the appliance
and voids all warranties.
WARNING
This appliance must be properly grounded, in accordance with all National,State and local electrical codes.
NOTE
Service must only be performed by AccuTemp Products, Inc. authorizedservice personnel. Service performed by unauthorized personnel will void
the warranty.
AT2T-3238-1 Rev. C ACCU-STEAM GAS GRIDDLE OWNERS MANUAL Page 15/29
SERVICE AND TROUBLESHOOTING (cont.)
Heat light will not come on Make sure the griddle is not hotter than the temperature you have it set for.
If you have turned down the temperature of the griddle, the heat light willnot come on again until the cooking surface drops below the temperature youhave set.
See if the heat light is coming on intermittently. While operating in a normalcondition, the heat light cycles on and off periodically when at temperature.
Call the AccuTemp Products, Inc Technical & Customer Support Departmentat +1-260-469-3040 or toll free at 1-800-480-0415.
Uneven or inaccurate surface temperatures Verify the surface temperature with an accurate surface probe thermometer.
Use of an infrared thermometer will not give an accurate reading ofthe griddle surface temperatures.
Call the AccuTemp Products, Inc Technical & Customer Support Departmentat +1-260-469-3040 or toll free at 1-800-480-0415.
Unit will not turn off This indicates a serious control malfunction. Turn off the griddles electrical supply at the source. Call the AccuTemp Products, Inc Technical & Customer Support Department
at +1-260-469-3040 or toll free at 1-800-480-0415.
NOTE
An AccuTemp Products, Inc. Technical & Customer Support Technician isavailable Monday thru Sunday, 7:00am to 7:00pm EST.
+1-260-469-3040 or 1-800-480-0415
13
2
45
6
7
8
ED
R: 0
80S
cale
: 1:2
She
et 1
of 1
C
Title
:
Rev
.D
raw
ing
No.
:S
ize:
AT0
H-3
035
-
GA
S A
PP
LIA
NC
ES
TD C
ON
VE
RS
ION
KIT
Acc
uTem
p P
rodu
cts,
Inc.
8415
N. C
linto
n P
ark
Fort
Way
ne, I
N 4
6825
Nam
eD
ate
1/03
/04
Dra
wn
Che
cked
1/13
/05
Pro
ject
Eng
1/13
/05
Do
Not
Sca
le D
raw
ing
-Fi
nish
:
-
Mat
eria
l:
Com
men
ts:
G. S
EIT
Z
D. S
TAN
LEY
G. S
EIT
Z
12
5 M
icro
Inch
es
Unl
ess
othe
rwis
e sp
ecifi
ed,
D
imen
sion
s: I
nche
s
Ben
ds: 9
0
Tol
eran
ces:
Ang
ular
1
2 P
lace
Dec
imal
.0
2
3
Pla
ce D
ecim
al
.005
T.I.
R
.005
GD
&T
Per
AN
SI Y
14.5
M
QTY
AT0
H-3
035-
1Q
TYA
T0H
-303
5-2
QTY
AT0
H-3
035-
3Q
TYA
T0H
-303
5-4
QTY
AT0
H-3
035-
5Q
TYA
T0H
-303
5-6
PA
RT
NO
.IT
EM
NO
.D
ES
CR
IPTI
ON
11
11
11
AT0
H-3
035
8G
AS
AP
PLI
AN
CE
STD
CO
NV
ER
SIO
N K
IT D
WG
11
11
11
AT0
S-2
780-
17
CA
RD
BO
AR
D B
OX
11
11
11
AT0
S-2
770-
16
FOA
M O
R B
UB
BLE
WR
AP
11
11
11
AT0
H-2
782-
15
ZIP
LOC
BA
G2
--
--
-A
T0B
-288
8-54
4O
RIF
ICE
--
3-
--
AT0
B-2
888-
524
OR
IFIC
E-
2-
--
-A
T0B
-288
8-51
4O
RIF
ICE
--
-2
--
AT0
B-2
888-
464
OR
IFIC
E-
--
--
3A
T0B
-288
8-40
4O
RIF
ICE
--
--
2-
AT0
B-2
888-
384
OR
IFIC
E-
--
11
1A
T0B
-288
8-59
3O
RIF
ICE
11
1-
--
AT0
B-2
888-
713
OR
IFIC
E
--
-1
11
AT0
H-3
034-
42
(PIL
OT)
RE
GU
LATO
R S
PR
ING
KIT
11
1-
--
AT0
H-3
034-
22
(PIL
OT)
RE
GU
LATO
R S
PR
ING
KIT
--
-1
11
AT0
H-3
034-
31
(MA
IN) R
EG
ULA
TOR
SP
RIN
G K
IT1
11
--
-A
T0H
-303
4-1
1(M
AIN
) RE
GU
LATO
R S
PR
ING
KIT
ECN
REV
DES
CRI
PTIO
ND
ATE
APPR
REVI
SIO
NS
EC
NR
EVD
ESC
RIP
TIO
ND
ATE
APPR
REV
ISIO
NS
PA
RT
No
MA
IN G
AS
R
EG
UL
AT
OR
PIL
OT
GA
S
RE
GU
LA
TO
R
GR
IDD
LE
SIZ
E /
CO
NV
ER
SIO
N T
O
GA
S T
YP
EA
T0H
-303
5-1
11 In
H2O
8 In
H2O
24"
PR
OP
AN
E G
AS
KIT
AT0
H-3
035-
211
In H
2O8
In H
2O36
" P
RO
PA
NE
GA
S K
ITA
T0H
-303
5-3
11 In
H2O
8 In
H2O
48"
PR
OP
AN
E G
AS
KIT
AT0
H-3
035-
45
In H
2O3.
5 In
H2O
24"
NA
TUR
AL
GA
S K
ITA
T0H
-303
5-5
5 In
H2O
3.5
In H
2O36
" N
ATU
RA
L G
AS
KIT
AT0
H-3
035-
65
In H
2O3.
5 In
H2O
48"
NA
TUR
AL
GA
S K
IT
RE
GU
LA
TO
R S
ET
PR
ES
SU
RE
S
dpeaksTextBoxPage 16/29
dpeaksTextBoxAT2T-3238-1 Rev.C ACCU-STEAM TM GAS GRIDDLE OWNERS MANUAL
AT2T-3238-1 Rev. C ACCU-STEAMTM GAS GRIDDLE OWNERS MANUAL Page 16 / 27
GAS GRIDDLE ORIFICE REFERENCE TABLE FOR ALITITUDE AND BTU CONTENT
NOTE: This Table represents the standard upper and lower ranges of BTU per cubic foot content. There is no relationship
between the natural gas BTU content and the propane BTU content as shown in each section of this Table.
HEAT VALUE BTU/CU FT. (NATURAL GAS - 990, PROPANE GAS - 2200)
PILOT BURNER24" GRIDDLE
MAIN
BURNER
36" GRIDDLE
MAIN
BURNER
48" GRIDDLE
MAIN
BURNERAltitude ft NG LP NG LP NG LP NG LP
0 - 3,999 #57 #71 #46 #54 #38 #51 #40 #52
4,000 - #59 #71 #46 #54 #41 #51 #43 #52
5,000 - #60 #71 #49 #55 #42 #52 #43 #52
6,000 - #61 #71 #49 #55 #42 #52 #44 #53
7,000 - #62 #71 #50 #55 #43 #52 #45 #53
8,000 - #63 #72 #51 #55 #44 #52 #45 #54
9,000 - #64 #73 #51 3/64 #45 #54 #47 #54
10,000 + #65 #74 #52 #56 #46 #54 #48 #55
HEAT VALUE BTU/CU FT. (NATURAL GAS - 1000, PROPANE GAS - 2300)
Altitude ft NG LP NG LP NG LP NG LP
0 - 3,999 #59 #70 #46 #54 #38 #51 #40 #52
4,000 - #59 #70 #46 #55 #38 #52 #40 #52
5,000 - #60 #70 #49 #55 #43 #52 #43 #53
6,000 - #61 #71 #49 #55 #43 #52 #44 #53
7,000 - #62 #72 #50 #55 #44 #53 #45 #53
8,000 - #63 #73 #51 3/64 #44 #53 #45 #53
9,000 - #64 #73 #51 #56 #45 #53 #47 #54
10,000 + #65 #74 #52 #57 #46 #54 #48 #55
HEAT VALUE BTU/CU FT. (NATURAL GAS - 1100, PROPANE GAS - 2400)
Altitude ft NG LP NG LP NG LP NG LP
0 - 3,999 #59 #70 #48 #54 #42 #51 #42 #52
4,000 - #61 #70 #49 #55 #42 #52 #44 #52
5,000 - #62 #71 #50 #55 #43 #52 #45 #53
6,000 - #63 #72 #50 #55 #44 #53 #45 #53
7,000 - #64 #72 #51 3/64 #45 #53 #46 #54
8,000 - #65 #73 #52 #56 #45 #53 #47 #54
9,000 - #66 #74 #52 #57 #47 #54 #48 #54
10,000 + #66 #74 #52 #57 #48 #55 #49 #55
HEAT VALUE BTU/CU FT. (NATURAL GAS - 1200, PROPANE GAS - 2500)
Altitude ft NG LP NG LP NG LP NG LP
0 - 3,999 #61 #71 #49 #54 #43 #51 #44 #52
4,000 - #63 #71 #50 #54 #44 #51 #44 #52
5,000 - #64 #72 #51 3/64 #44 #53 #45 #53
6,000 - #64 #72 #51 3/64 #45 #53 #47 #55
7,000 - #65 #72 #52 3/64 #46 #54 #48 #55
8,000 - #66 #72 #52 #57 #48 #54 #49 #55
9,000 - #66 #72 #53 #57 #48 #54 #49 #55
10,000 + #67 #72 #53 #57 #49 #55 #50 3/64
HEAT VALUE BTU/CU FT. (NATURAL GAS - 1300, PROPANE GAS - 2700)
Altitude ft NG LP NG LP NG LP NG LP
0 - 3,999 #62 #71 #50 #55 #44 #52 #45 #53
4,000 - #64 #72 #51 3/64 #45 #53 #47 #53
5,000 - #65 #73 #51 3/64 #45 #53 #48 #54
6,000 - #66 #73 #52 #56 #47 #53 #48 #54
7,000 - #66 #74 #53 #56 #48 #54 #49 #54
8,000 - #67 #74 #53 #57 #48 #54 #50 #55
9,000 - #68 #74 #53 #58 #49 #55 #50 #55
10,000 + #69 #75 #54 #59 #50 #55 #51 3/64
Unl
ess
othe
rwis
e sp
ecifi
ed,
D
imen
sion
s: I
nche
s
Ben
ds: 9
0
Tol
eran
ces:
Ang
ular
1
2 P
lace
Dec
imal
.0
2
3
Pla
ce D
ecim
al
.005
T.I.
R
.005
12
5 M
icro
Inch
esG
D&T
Per
AN
SI Y
14.5
M
AT2
A-2
813-
224
" X
24"
GR
IDD
LE E
XT T
HER
M
BBAD E F
F
G
G G
QTYAT2A-2813-24
QTYAT2A-2813-23
QTYAT2A-2813-22
QTYAT2A-2813-21
QTYAT2A-2813-20
QTYAT2A-2813-19
QTYAT2A-2813-18
QTYAT2A-2813-17
QTYAT2A-2813-16
QTYAT2A-2813-15
QTYAT2A-2813-14
QTYAT2A-2813-13
QTYAT2A-2813-12
QTYAT2A-2813-11
QTYAT2A-2813-10
QTYAT2A-2813-9
QTYAT2A-2813-8
QTYAT2A-2813-7
QTYAT2A-2813-6
QTYAT2A-2813-5
QTYAT2A-2813-4
QTYAT2A-2813-3
QTYAT2A-2813-2
QTYAT2A-2813-1
PAR
T N
O.
ITEM
D
ESC
RIP
TIO
N
11
11
11
11
11
11
11
11
11
11
11
11
AT0
A-2
736-
942
MO
V- T
ERM
INA
LS A
SSEM
BLY
11
11
11
11
11
11
11
11
11
11
11
11
AT0
L-29
36-1
41SH
IPPI
NG
TA
G P
OW
ER C
OR
D1
11
11
11
11
11
11
11
11
11
11
11
1A
T0L-
2936
-240
SHIP
PIN
G T
AG
GA
S R
EGU
LATO
R1
11
11
11
11
11
11
11
11
11
11
11
1A
T2L-
2013
-139
DA
TA T
AG
GG
11
11
11
11
11
11
11
11
11
11
11
11
AT0
L-27
99-1
38O
VER
LAY,
WA
RN
ING
, GA
S FI
RED
11
11
11
11
11
11
11
11
11
11
11
11
AT0
L-28
02-1
37O
VER
LAY,
NO
TIC
E, M
OB
ILE
APP
LIA
NC
E 8
88
88
88
88
88
88
88
88
88
88
88
8A
T0F-
2668
-236
NU
TSER
T,
-20
HEX
6
66
66
66
66
66
66
66
66
66
66
66
6A
T0F-
2778
-510
0235
NU
T,
-20U
NC
-2B
ZIN
C P
LATE
D H
EX M
AC
HIN
E SC
REW
3636
3636
3636
3636
3232
3232
3636
3636
3636
3636
3232
3332
AT0
F-10
17-4
1002
34N
UT,
#10
-24U
NC
HEX
SER
RA
TED
66
66
66
66
66
66
66
66
66
66
66
66
AT0
F-19
22-5
0002
33W
ASH
ER, 1
/4"
HEL
ICA
L SP
RIN
G Z
INC
PLA
TED
LO
CK
66
66
66
66
66
66
66
66
66
66
66
66
AT0
F-10
46-3
1030
32SC
REW
, #8-
32 x
3/8
PH
LP T
RU
SS H
EAD
66
66
66
66
66
66
66
66
66
66
66
66
AT0
F-28
75-5
1062
31SC
REW
, 1/4
-20U
NC
X 3
/4 H
EX H
D M
AC
H5
55
54
44
42
22
25
55
54
44
42
22
2A
T0F-
2755
-410
4030
SCR
EW, #
10-2
4UN
C X
1/2
PH
ILIP
S R
OU
ND
HEA
D
MA
CH
INE
291
11
11
11
11
11
11
11
11
11
11
11
1A
T0E-
2945
-128
HEY
CO
STR
AIG
HT-
THR
U1
11
11
11
11
11
11
11
11
11
11
11
1A
T0H
-257
6-1
27G
RO
MM
ET, 7
/8"
NYL
ON
11
11
11
11
11
11
11
11
11
11
11
11
AT2
P-24
65-1
263/
4" N
PT C
LOSE
NIP
PLE
11
11
11
11
11
11
11
11
11
11
11
11
AT2
P-24
66-1
25EL
BO
W, R
EDU
CIN
G-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1A
T2P-
2447
-224
PIPE
, "
NPT
X 2
9.5"
BLA
CK
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
AT2
P-24
47-1
24PI
PE,
" N
PT X
25.
10"
BLA
CK
11
11
11
11
11
11
11
11
11
11
11
11
AT0
P-21
04-1
233/
8" F
LEX
TUB
ING
13"
LG
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
AT0
P-28
46-1
22FL
EX T
UB
ING
31"
LG
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
AT0
P-28
46-2
22FL
EX T
UB
ING
27"
LG
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AT2
G-1
702-
121
GA
SKET
11
11
11
11
11
11
11
11
11
11
11
11
AT2
A-2
821-
120
HA
RN
ESS
ASS
EMB
LY O
T TO
CO
NTR
OL
PAN
EL1
11
11
11
11
11
11
11
11
11
11
11
1A
T0A
-291
1-1
19A
C P
OW
ER C
OR
D1
11
11
11
11
11
11
11
11
11
11
11
1A
T0E-
2885
-218
SEN
SOR
, REP
LAC
EAB
LE-
--
--
--
-2
22
2-
--
--
--
--
--
-A
T0B
-288
8-54
17O
RIF
ICE
33
33
--
--
--
--
--
--
--
--
--
--
AT0
B-2
888-
5217
OR
IFIC
E-
--
-2
22
2-
--
--
--
--
--
--
--
-A
T0B
-288
8-51
17O
RIF
ICE
--
--
--
--
--
--
--
--
--
--
22
22
AT0
B-2
888-
4617
OR
IFIC
E-
--
--
--
--
--
-3
33
3-
--
--
--
-A
T0B
-288
8-40
17O
RIF
ICE
--
--
--
--
--
--
--
--
22
22
--
--
AT0
B-2
888-
3817
OR
IFIC
E1
11
11
11
11
11
1-
--
--
--
--
--
-A
T0B
-288
8-71
16O
RIF
ICE
--
--
--
--
--
--
11
11
11
11
11
11
AT0
B-2
888-
5916
OR
IFIC
E1
11
11
11
11
11
11
11
11
11
11
11
1A
T0E-
2086
-115
CO
RD
GR
IP L
OC
KN
UT
11
11
11
11
11
11
11
11
11
11
11
11
AT0
E-10
49-3
14
" ST
RA
IN R
ELIE
F1
11
11
11
11
11
11
11
11
11
11
11
1A
T2A
-291
6-2
13H
IGH
LIM
IT O
VER
TEM
P A
SSEM
BLY
121
11
11
11
11
11
11
11
11
11
11
11
1A
T2A
-259
2-5
115"
GR
EASE
SPO
UT
EXTE
NSI
ON
11
11
11
11
11
11
11
11
11
11
11
11
AT2
A-2
137-
110
GR
EASE
PA
N R
AIL
11
11
--
--
--
--
11
11
--
--
--
--
AT2
A-2
855-
39
INN
ER F
LUE
PAN
EL A
SSY
48"
--
--
11
11
--
--
--
--
11
11
--
--
AT2
A-2
855-
29
INN
ER F
LUE
PAN
EL A
SSY
36"
--
--
--
--
11
11
--
--
--
--
11
11
AT2
A-2
855-
19
INN
ER F
LUE
PAN
EL A
SSY
24"
11
11
--
--
--
--
11
11
--
--
--
--
AT2
M-2
803-
38
OU
TER
FLU
E 48
"-
--
-1
11
1-
--
--
--
-1
11
1-
--
-A
T2M
-280
3-2
8O
UTE
R F
LUE
36"
--
--
--
--
11
11
--
--
--
--
11
11
AT2
M-2
803-
18
OU
TER
FLU
E 24
"1
11
11
11
11
11
1-
--
--
--
--
--
-A
T2A
-285
0-2
7G
AS
CO
NTR
OL
VALV
E A
SSEM
BLY
PR
OPA
NE
--
--
--
--
--
--
11
11
11
11
11
11
AT2
A-2
850-
17
GA
S C
ON
TRO
L VA
LVE
ASS
EMB
LY N
ATU
RA
L G
AS
11
11
11
11
--
--
11
11
11
11
--
--
AT2
M-2
044-
36
PLA
TE, F
RO
NT
SKIR
T C
OVE
R-
2-
2-
2-
2-
2-
2-
2-
2-
2-
2-
2-
2A
T2M
-288
0-2
5SI
DE
SKIR
T 29
"2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-A
T2M
-288
0-1
5SI
DE
SKIR
T 24
"1
11
1-
--
--
--
-1
11
1-
--
--
--
-A
T2A
-281
5-3
4FR
ON
T SK
IRT
48"
ASS
EMB
LY-
--
-1
11
1-
--
--
--
-1
11
1-
--
-A
T2A
-281
5-2
4FR
ON
T SK
IRT
36"
ASS
EMB
LY-
--
--
--
-1
11
1-
--
--
--
-1
11
1A
T2A
-281
5-1
4FR
ON
T SK
IRT
24"
ASS
EMB
LY1
1-
--
--
--
--
-1
1-
--
--
--
--
-A
T2A
-281
9-6
3C
ON
TRO
L PA
NEL
48"
100
SER
IES
--
--
11
--
--
--
--
--
11
--
--
--
AT2
A-2
819-
53
CO
NTR
OL
PAN
EL 3
6" 1
00 S
ERIE
S-
--
--
--
-1
1-
--
--
--
--
--
1-
-A
T2M
-281
9-4
3C
ON
TRO
L PA
NEL
24"
100
SER
IESS
--
11
--
--
--
--
--
11
--
--
--
--
AT2
A-2
819-
33
CO
NTR
OL
PAN
EL 4
8"
--
--
--
11
--
--
--
--
--
11
--
--
AT2
A-2
819-
23
CO
NTR
OL
PAN
EL 3
6"-
--
--
--
--
-1
1-
--
--
--
-1
-1
1A
T2A
-281
9-1
3C
ON
TRO
L PA
NEL
24"
11
11
--
--
--
--
11
11
--
--
--
--
AT2
A-2
818-
32
CO
MB
UST
ION
CH
AM
BER
-
--
-1
11
1-
--
--
--
-1
11
1-
--
-A
T2A
-281
8-2
2C
OM
BU
STIO
N C
HA
MB
ER
--
--
--
--
11
11
--
--
--
--
11
11
AT2
A-2
818-
12
CO
MB
UST
ION
CH
AM
BER
-
1-
1-
--
--
--
--
1-
1-
--
--
--
-A
T2A
-280
8-6
1G
RID
DLE
CH
AM
BER
ASS
EMB
LY 4
8 x
29-
--
--
1-
1-
--
--
--
--
1-
1-
--
-A
T2A
-280
8-5
1G
RID
DLE
CH
AM
BER
ASS
EMB
LY 3
6 x
29-
--
--
--
--
1-
1-
--
--
--
--
1-
1A
T2A
-280
8-4
1G
RID
DLE
CH
AM
BER
ASS
EMB
LY 2
4 x
291
-1
--
--
--
--
-1
-1
--
--
--
--
-A
T2A
-280
8-3
1G
RID
DLE
CH
AM
BER
ASS
EMB
LY 4
8 x
24-
--
-1
-1
--
--
--
--
-1
-1
--
--
-A
T2A
-280
8-2
1G
RID
DLE
CH
AM
BER
ASS
EMB
LY 3
6 x
24-
--
--
--
-1
-1
--
--
--
--
-1
-1
-A
T2A
-280
8-1
1G
RID
DLE
CH
AM
BER
ASS
EMB
LY 2
4 x
24
ECN
REV
DES
CR
IPTI
ON
DA
TEA
PPR
REV
ISIO
NS
380
GR
EM
OV
ED
: (B
OM
) ITE
M 1
2 W
AS
AT2
M-2
768-
2,
ITE
M 2
9 W
AS
AT0
F-27
55-2
1020
; CH
G'D
: (IT
EM
36
) AT0
F-26
68-2
WA
S A
T0F-
2047
-211
-30-
07D
PS/A
LB
280
FC
HG
D: A
T0E
-288
5-2
WA
S A
T0E
-288
5-1;
A
DD
ED
: (A
LL G
PS
) ITM
40
AT0
L-29
36-2
05-2
5-06
LEC
/ATP
230
ER
EM
OV
E IT
EM
#40
AT1
L-U
SA
06-1
5-05
RP/
ALB
225
DC
HG
D: U
PD
ATE
D P
ICTO
RIA
L V
IEW
S T
O
SH
OW
EX
TEN
DE
D F
LUE
, AD
DE
D: I
TM 4
2 A
T0A
-273
6-9
ALL
GP
S05
-19-
05G
LS/A
TP
188
C
RM
VD
: (S
HT
2 TO
P R
H V
IEW
) VIS
IBIL
ITY
OF
AT2
G-1
702
CO
NTR
OL
PA
NE
L G
AS
KE
T,
AD
DE
D: (
SH
T 2)
2 R
EG
ULA
TOR
AD
JUS
TME
NT
NO
TES
, ITM
34
BA
LLO
ON
, NO
TE T
O S
EE
NO
TE
1, N
OTE
TO
SE
E N
OTE
2
01-0
5-05
GLS
/AP
179
BC
HG
D: I
TEM
29
AT0
F-27
55-2
1020
WA
S A
T0F-
2755
-210
30, I
TEM
21
DE
SC
RIP
TIO
N, G
AS
KE
T W
AS
GA
SK
ET,
SK
IRT
11-1
7-04
GLS
/AP
164
AR
EP
LAC
E Q
TY 3
ALL
GR
OU
PS
AT0
F-10
46-
3103
0 W
AS
AT0
F-27
55-3
1030
, CH
G'D
GP
-17
THR
U -2
0 A
T0B
-288
8-51
WA
S -5
2, G
P-2
1 TH
RU
-2
4 A
T0B
-288
8-52
WA
S -5
110
-20-
04G
LS/A
LB
-08
-25-
04G
LS
EDR
: 062
Scal
e: 1
:1Sh
eet 1
of 2
D
Title
:
Rev
.D
raw
ing
No.
:Si
ze:
AT2
A-2
813
GG
AS
GR
IDD
LE A
SSY
Acc
uTem
p Pr
oduc
ts, I
nc.
8415
N. C
linto
n Pa
rkFo
rt W
ayne
, IN
468
25
Nam
eD
ate
05-0
5-04
ALB
Dra
wn
Che
cked
GLS
05-0
5-04
Proj
ect E
ng
Do
Not
Sca
le D
raw
ing
N/A
Fini
sh:
N/A
Mat
eria
l:
Com
men
ts:
05-0
5-04
GLS
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksTextBoxPage 18/28
dpeaksTextBoxAT2T-3238-1 Rev.C ACCU-STEAMTM GAS GRIDDLE OWNERS MANUAL
Unl
ess
othe
rwis
e sp
ecifi
ed,
D
imen
sion
s: I
nche
s
Ben
ds: 9
0
Tol
eran
ces:
Ang
ular
1
2 P
lace
Dec
imal
.0
2
3
Pla
ce D
ecim
al
.005
T.I.
R
.005
12
5 M
icro
Inch
esG
D&T
Per
AN
SI Y
14.5
M
211131
89
2
24
31
22
7
330
34
34
3431
32
34
2526
32
15
18
21
4
5
23
10
19
28
20
16
3533
534
1914
EXPL
OD
ED V
IEW
GA
S G
RID
DLE
34
17
39
38
37
21
41
34
36
21A
DD
SEC
ON
D S
HO
RT
GA
SKET
UN
DER
LA
RG
E G
ASK
ET T
O F
ILL
IN C
OR
NER
RA
DIU
S B
OTH
EN
DS
32
34
AA
BB
NO
TES
1. A
DJU
ST M
AIN
GA
S R
EGU
LATO
R C
ON
TRO
L VA
LVE
T
O 5
" W
.C. F
OR
NA
TUR
AL
GA
S, 1
0" W
.C. F
OR
PR
OPA
NE
L
OC
ATE
D IN
ITEM
#7
2. A
DJU
ST P
ILO
T R
EGU
LATO
R T
O 3
.5"
W.C
. FO
R N
ATU
RA
L G
AS,
8
" W
.C. F
OR
PR
OPA
NE
LOC
ATE
D IN
ITEM
#7
C
C
34
SEE
NO
TE 2
SEE
NO
TE 1
C
C
C
42D
40F
GG
3627
346
CO
NTR
OL
PAN
EL &
GA
SKET
NO
T SH
OW
N
EDR
: 062
Scal
e: 1
:4Sh
eet 2
of 2
D
Title
:
Rev
.D
raw
ing
No.
:Si
ze:
AT2
A-2
813
G
GA
S G
RID
DLE
ASS
Y
Acc
utem
p Pr
oduc
ts, I
nc.
8415
N. C
linto
n Pa
rkFo
rt W
ayne
, IN
468
25
Nam
eD
ate
05-0
5-04
ALB
Dra
wn
Che
cked
GLS
05-0
5-04
Proj
ect E
ng
Do
Not
Sca
le D
raw
ing
N/A
Fini
sh:
N/A
Mat
eria
l:
Com
men
ts:
05-0
5-04
GLS
dpeaksTextBoxPage 19/28
dpeaksTextBoxAT2T-3238-1 Rev.C ACCU-STEAMTM GAS GRIDDLE OWNERS MANUAL
Unl
ess
othe
rwis
e sp
ecifi
ed,
D
imen
sion
s: I
nche
s
Ben
ds: 9
0
Tol
eran
ces:
Ang
ular
1
2 P
lace
Dec
imal
.0
2
3
Pla
ce D
ecim
al
.005
T.I.
R
.005
12
5 M
icro
Inch
esG
D&T
Per
AN
SI Y
14.5
M
AT2
A-2
818-
1C
OM
BU
STIO
N C
HA
MB
ER 2
4"
20
1022
1920
220
614
2311
2314
6
3 203 20
20
2087
2
21
18 5
A A
24C
25D
BCD D
D
11
1A
T0A
-350
6-1
25G
RO
UN
DIN
G H
AR
NES
S A
SSEM
BLY
11
1A
T2M
-329
9-1
24SH
IELD
, WIR
E H
EAT
22
2A
T0P-
2097
-223
CO
MPR
ESSI
ON
FIT
TIN
G
11
1A
T2A
-225
5-2
22PI
LOT
BU
RN
ER A
SSY
32
2A
T0F-
2909
-121
NPT
PIP
E LO
CK
NU
T
3226
22A
T0F-
1017
-410
0220
NU
T, #
10-2
4UN
C H
EX S
ERR
ATE
D
19
11
1A
T0F-
2908
-118
HO
SE C
LAM
P
1-
-A
T2P-
2105
1718
.5"
LON
G 3
/8 F
LEXT
UB
E C
OM
P EN
DS
1-
-A
T0P-
2096
-116
ELB
OW
90
CO
MPR
ESSI
ON
22
-A
T2M
-282
4-1
15B
AR
RIE
R, F
LU G
AS
- SH
OR
T
--
2A
T0P-
2276
-114
SEA
MLE
SS T
UB
ING
22
-A
T0P-
2276
-214
SEA
MLE
SS T
UB
ING
11
1A
T0P-
2845
-113
MA
LE A
DA
PTER
, 5/8
" O
D F
LAR
E X
1/2
NPT
X 3
/8 N
PT
1-
-A
T0P-
2844
-112
CR
OSS
, 1/2
NPT
SC
H 4
0
-1
1A
T0P-
2090
-111
TEE
1/2
NPT
SC
H 4
0
11
1A
T0P-
2094
-110
ELB
OW
90
CO
MPR
ESSI
ON
11
1A
T2M
-288
1-1
9D
EFLE
CTO
R, G
AS
GR
IDD
LE
11
1A
T2M
-279
2-1
8B
RK
T, S
TEP
11
1A
T2M
-279
1-1
7SP
AC
ER,
BU
RN
ER
32
2A
T0B
-289
1-1
6EL
BO
W 9
0 C
OM
PRES
SIO
N
11
1A
T0B
-289
0-1
5O
RIF
ICE,
AD
APT
ER
32
-A
T2B
-209
9-1
430
,000
BTU
IR M
AIN
BU
RN
ER
--
2A
T2B
-213
1-1
320
,000
BTU
IR M
AIN
BU
RN
ER
--
1A
T2M
-279
5-4
2B
AR
RIE
R, F
LUE
GA
S
1-
-A
T2M
-279
5-3
2B
AR
RIE
R, F
LUE
GA
S
12
-A
T2M
-279
5-2
2B
AR
RIE
R, F
LUE
GA
S
--
1A
T2M
-279
5-1
2B
AR
RIE
R, F
LUE
GA
S
1-
-A
T2A
-279
0-3
1C
OM
BU
STIO
N B
OX
ASS
EMB
LY
--
1A
T2A
-279
0-1
1C
OM
BU
STIO
N B
OX
ASS
EMB
LY
-1
-A
T2A
-279
0-2
1C
OM
BU
STIO
N B
OX
ASS
EMB
LY
QTYAT2A-2818-3
QTYAT2A-2818-2
QTYAT2A-2818-1
PAR
T N
O.
ITEM
DES
CR
IPTI
ON
373
DR
EM
OV
ED
: (B
OM
, ITE
M#1
9) W
AS
AT0
F-10
17-
3100
2; C
HG
'D: (
BO
M, Q
TY, I
TEM
#20)
22
WA
S 1
4,
26 W
AS
18,
32
WA
S 2
0; A
DD
ED
: ITE
M #
25 (A
T0A
-35
06-1
)12
-14-
07LE
C/A
LB
283
CA
DD
ED
: ITE
M #
24 (A
T2M
-329
9-1)
TO
GR
OU
PS
-1
THR
U -3
06-2
3-06
ALB
/LEC
181
BC
HG
D:
ITE
M 2
0 A
T0F-
2908
-1, W
AS
AT2
M-2
908-
111
-29-
04A
P/G
LS
164
AC
HG
'D: A
T0F-
1017
-410
02 W
AS
-410
01: A
T0F-
1017
-31
002
WA
S -3
1001
08-1
1-04
ALB
/GLS
ECN
REV
DES
CR
IPTI
ON
DA
TEA
PPR
REV
ISIO
NS
EDR
: 045
FSc
ale:
1:3
Shee
t 1 o
f 3
D
Title
:
Rev
.D
raw
ing
No.
:Si
ze:
AT2
A-2
818
D
CO
MB
UST
ION
CH
AM
BER
A
SSEM
BLY
Acc
uTem
p Pr
oduc
ts, I
nc.
8415
N. C
linto
n Pa
rkFo
rt W
ayne
, IN
468
25
Nam
eD
ate
Dra
wn
Che
cked
Proj
ect E
ng
Do
Not
Sca
le D
raw
ing
N/A
Fini
sh:
N/A
Mat
eria
l:
Com
men
ts:
ALB
06-1
4-04
06-1
4-04
GLS
GLS
06-1
4-04
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksRectangle
dpeaksTextBoxPage 20/29
dpeaksTextBoxAT2T-3238-1 Rev.C ACCU-STEAMTM GAS GRIDDLE OWNERS MANUAL
Unl
ess
othe
rwis
e sp
ecifi
ed,
D
imen
sion
s: I
nche
s
Ben
ds: 9
0
Tol
eran
ces:
Ang
ular
1
2 P
lace
Dec
imal
.0
2
3
Pla
ce D
ecim
al
.005
T.I.
R
.005
12
5 M
icro
Inch
esG
D&T
Per
AN
SI Y
14.5
M
AT2
A-2
818-
2C
OM
BU
STIO
N C
HA
MB
ER 3
6"
202
152
15
20 9
20
10
614
2311
2314
613
2120
20
7 8 20
51824
C
25D
EDR
: 045
FSc
ale:
1:3
Shee
t 2 o
f 3
D
Title
:
Rev
.D
raw
ing
No.
:Si
ze:
AT2
A-2
818
D
CO
MB
UST
ION
CH
AM
BER
A
SSEM
BLY
Acc
uTem
p Pr
oduc
ts, I
nc.
8415
N. C
linto
n Pa
rkFo
rt W
ayne
, IN
468
25
Nam
eD
ate
Dra
wn
Che
cked
Proj
ect E
ng
Do
Not
Sca
le D
raw
ing
N/A
Fini
sh:
N/A
Mat
eria
l:
Com
men
ts:
ALB
06-1
4-04
06-1
4-04
GLS
GLS
06-1
4-04
dpeaksTextBoxPage 21/28
dpeaksTextBoxAT2T-3238-1 Rev.C ACCU-STEAMTM GAS GRIDDLE OWNERS MANUAL
Unl
ess
othe
rwis
e sp
ecifi
ed,
D
imen
sion
s: I
nche
s
Ben
ds: 9
0
Tol
eran
ces:
Ang
ular
1
2 P
lace
Dec
imal
.0
2
3
Pla
ce D
ecim
al
.005
T.I.
R
.005
12
5 M
icro
Inch
esG
D&T
Per
AN
SI Y
14.5
M
AT2
A-2
818-
3C
OM
BU
STIO
N C
HA
MB
ER 4
8"
22
20
18 5 10
215
220
2015
614
2313
1216
2314
617
6
4
20
21
2087
4 20
24C
25D
EDR
: 045
FSc
ale:
1:3
Shee
t 3 o
f 3
D
Title
:
Rev
.D
raw
ing
No.
:Si
ze:
AT2
A-2
818
D
CO
MB
UST
ION
CH
AM
BER
A
SSEM
BLY
Acc
uTem
p Pr
oduc
ts, I
nc.
8415
N. C
linto
n Pa
rkFo
rt W
ayne
, IN
468
25
Nam
eD
ate
Dra
wn
Che
cked
Proj
ect E
ng
Do
Not
Sca
le D
raw
ing
N/A
Fini
sh:
N/A
Mat
eria
l:
Com
men
ts:
ALB
06-1
4-04
06-1
4-04
GLS
GLS
06-1
4-04
dpeaksTextBoxPage 22/29
dpeaksTextBoxAT2T-3238-1 Rev.C ACCU-STEAMTM GAS GRIDDLE OWNERS MANUAL
.07
- .1
0
G
F
GD
ET
AIL
A
SC
AL
E 3
: 1
CE
RA
MIC
SU
RF
AC
E
IGN
ITO
R R
OD
SE
NS
OR
RO
D
LO
WE
ST
PO
INT
S O
F C
ER
AM
IC S
UR
FA
CE
GR
OU
ND
RO
DT
O C
ON
TA
CT
NO
TE
: G
RO
UN
D R
OD
TO
BE
PO
SIT
ION
ED
ON
TO
G
.16
.12
.0
5
DE
TA
IL B
S
CA
LE
3 :
1G
CE
RA
MIC
TIL
E
H
FO
R G
RO
UN
D R
OD
CO
NT
AC
T T
O .
04
0
1H
6
B
.08
MA
X
G
3
1
AT
2A
-2255-2
79
10
F
5
G
2X
HA
ND
TIG
HT
EN
ON
LY
G
8
HO
LE
PA
TT
ER
N C
ON
SIS
TE
NT
AC
RO
SS
EN
TIR
E C
ER
AM
IC T
ILE
SU
RF
AC
E
A
DIM
EN
SIO
N I
S T
AK
EN
FR
OM
OU
TS
IDE
FL
AN
GE
OF
AT
2A
-27
85
-1 T
O O
UT
SID
E F
LA
NG
E O
F A
T2
M-2
79
3-1
G G
EDFF DE
E
5. IF
UN
AB
LE
TO
AC
HIE
VE
TH
E M
INIM
UM
mV
AF
TE
R S
EV
ER
AL
TR
IES
,
G
ST
EP
4.
G
FF
RE
PE
AT
TH
E S
ET
UP
AN
D C
AL
IBR
AT
ION
PR
OC
ED
UR
E.
RE
PL
AC
E T
HE
SE
NS
OR
/IG
NIT
OR
PR
OB
E A
SS
Y (
ITE
M 3
) A
ND
SE
TU
P A
ND
CA
LIB
RA
TIO
N:
1. A
SS
EM
BL
E A
ND
PO
SIT
ION
RO
DS
AS
SH
OW
N IN
DE
TA
IL "
A".
2. A
LL
OW
UN
IT T
O W
AR
M U
P A
PP
RO
XIM
AT
EL
Y 2
0 S
EC
ON
DS
UN
TIL
TH
E IG
NIT
OR
ST
OP
S S
PA
RK
ING
. IF
TH
E U
NIT
WIL
L N
OT
ST
OP
SP
AR
KIN
G O
R IN
TE
RM
ITT
AN
TL
Y S
PA
RK
S,
AD
JU
ST
TH
E P
RO
BE
S A
ND
RE
PE
AT
TH
IS S
TE
P.
3. T
HE
mV
RE
AD
ING
MU
ST
BE
A M
INIM
UM
OF
40m
V.
4. IF
TH
E R
EA
DIN
G IS
LE
SS
TH
AN
40m
V, R
EP
OS
ITIO
N
TH
E S
EN
SO
R R
OD
OV
ER
TH
E R
OW
S O
F H
OL
ES
LO
CA
TE
D
IN
TH
E V
AL
LE
Y O
F T
HE
CE
RA
MIC
SU
RF
AC
E A
ND
RE
PE
AT
NO
TE
S:
1G
QT
YG
P-2
PA
RT
NO
.IT
EM
NO
.D
ES
CR
IPT
ION
2A
T0
F-2
66
6-4
00
00
10
WA
SH
ER
, #
10
IN
TE
RN
AL
TO
OT
H L
OC
K
2A
T0F
-2755-4
1022
9S
CR
EW
, #
10-2
4U
NC
X 1
/4 P
HIL
IPS
RO
UN
D H
EA
D M
AC
HIN
E
1A
T2
M-2
87
1-1
8B
RK
T,
GR
OU
ND
PL
AN
E
1A
T2M
-2793-1
7B
RK
T, B
UR
NE
R &
IG
NT
R/S
NS
R
2A
T0F
-1017-4
1001
6#
10-2
4U
NC
HE
X S
ER
RA
TE
D N
UT
2A
T0F
-2755-4
1040
5S
CR
EW
, #
10-2
4U
NC
X 1
/2 P
HIL
IPS
RO
UN
D H
EA
D M
AC
HIN
E
4
1A
T2
E-2
08
3-1
3IG
NIT
OR
/ S
EN
SO
R P
RO
BE
2
1A
T2A
-2785-1
1P
ILO
T B
UR
NE
R/T
UB
E A
SS
Y
Com
ments
:
2/1
7/2
004
ED
R: 43
Sheet 1 o
f 1
D
Title
:
Rev.
Dra
win
g N
o.:
Scale
: 1:1
Siz
e:
AT
2A
-2255
Fin
ish:
GA
S G
RID
DL
EP
ILO
T B
UR
NE
R A
SS
YM
ate
rial:
Fo
rt W
ayn
e, IN
46825
Nam
e
H
Date
ALB
Dra
wn
11/1
1/2
003
Checked
2/1
7/2
004
Pro
ject E
ng
GLS
N/A
Do N
ot S
cale
Dra
win
g
N/A
Accu
tem
p P
rod
ucts
, In
c.
8415 N
. C
lin
ton
Park
GLS
125 M
icro
Inches
Unle
ss o
therw
ise s
pecifie
d,
D
imensio
ns: Inches
GD
&T
Per
AN
SI Y
14.5
M
B
ends: 90
T
ole
rances:
A
ngula
r
1
2
Pla
ce D
ecim
al
.02
3
Pla
ce D
ecim
al
.005
T
.I.R
.0
05
EC
NR
EV
DE
SC
RIP
TIO
ND
AT
EA
PP
R
29
9H
CH
GD
: (R
H V
IEW
) .0
8 M
AX
WA
S .
06
MA
X;
AD
DE
D:
(DE
TA
IL B
) .0
7 -
.1
00
9/2
1/0
6L
EC
/AT
P
RE
VIS
ION
SE
CN
RE
VD
ES
CR
IP
TI
ON
DA
TE
AP
PR
A
CH
G'D
:
.1
50
+/
-.
05
0
WA
S
.1
25
+/
-.
01
5,
.0
15
+/
-.
02
0
WA
S
.0
15
+/
-.
01
5,
.1
35
+/
-.
02
5
WA
S
.1
35
+/
-.
01
0,
.
07
0+
/-
.0
50
W
AS
.
11
5+
/-
.0
05
,
05
/1
3/
03
GL
S
B
CH
G'D
:
AT
2A
-2
25
5-
1
WA
S
AT
2A
-2
25
5,
IT
EM
1
A
T2
A-
27
85
-1
W
AS
A
T2
B-
20
98
,
AD
DE
D:
D
ET
AI
L
A
&
B,
S
ET
UP
A
ND
CA
LI
BR
AT
IO
N
NO
TE
S
02
/1
6/
04
GL
S
08
4C
CH
G'
D:
I
TE
M
#6
W
AS
A
T0
F-
27
78
-4
10
01
,
AD
DE
D
GR
OU
P
20
3/
22
/0
4G
LS
09
1D
CH
G'D
:
IT
EM
#
7
WA
S
AT
2A
-2
79
4-
1,
Q
TY
IT
EM
#
5
GR
OU
P
1
WA
S
40
4/
14
/0
4G
LS
09
3E
CH
G'
D
GP
-2
I
TE
M
#6
Q
TY
2
W
AS
Q
TY
4
;
IT
EM
#
8
AT
2M
-2
87
1-
1
WA
S
AT
2A
-2
87
3-
1;
AD
DE
D
IT
EM
#
9
AT
0F
-2
75
5-
41
02
2;
N
OT
E
TO
G
P-
1
OB
SO
LE
TE
F
OR
A
LL
P
AS
T
AN
D
FU
TU
RE
A
PP
LI
CA
TI
ON
U
SE
A
T2
A-
22
55
-2
04
-2
1-
04
AL
B
04
-2
1-
04
GL
S
10
1F
CH
G'D
N
OT
E
6
&
7;
1
9m
v
WA
S
17
mv
,
IT
EM
#6
;
AT
0F
-1
01
7-
41
00
1
WA
S
AT
0F
-1
01
7-
1,
DI
MS
:
.0
7-
.1
0
WA
S
.0
7,
G
RO
UN
D
RO
D
NO
TE
;
AD
DE
D
IT
EM
#
10
A
T0
F-
26
66
-4
00
00
TO
G
P-
2
05
-1
9-
04
A
LB
GL
S
28
9G
RM
V
D:
A
T2
A-
22
55
-1
,
NO
TE
F
OR
A
LL
PA
ST
A
ND
F
UT
UR
E
AP
PL
IC
AT
IO
NS
U
SE
AT
2A
-2
25
5-
2,
D
ET
AI
L
B;
(
BO
M)
I
TM
2
AT
2M
-2
15
4,
I
TM
4
A
T0
F-
20
47
-1
;
CH
G
D:
DE
TA
IL
A
N
OW
T
AK
EN
F
RO
M
AT
2A
-2
25
5-
2,
V
IE
W
TI
TL
E
WA
S
AT
2A
-2
25
5-
2
OT
HE
RW
IS
E
SA
ME
A
S
AT
2A
-2
25
5-
1;
(B
TM
L
H
CO
RN
ER
,
SE
TU
P
AN
D
CA
LI
BR
AT
IO
N)
R
EV
IS
ED
A
LL
N
OT
ES
;
(B
OM
)
IT
M
3
AT
2E
-2
08
3-
1
WA
S
AT
2E
-
20
83
;
(D
ET
AI
L
A)
.
12
.
05
W
AS
.
15
.
05
0,
(.
16
)
WA
S
(.
20
);
A
DD
ED
:
DE
TA
IL
B
,
NO
TE
1;
(
AT
2A
-2
25
5-
2)
R
H
VI
EW
;
(L
H
VI
EW
)
2X
HA
ND
T
IG
HT
EN
O
NL
Y,
H
OL
E
PA
TT
ER
N
CO
NS
IS
TE
NT
A
CR
OS
S
EN
TI
RE
C
ER
AM
IC
TI
LE
S
UR
FA
CE
07
/2
8/
06
LE
C/
AT
P
RE
VI
SI
ON
S
dpeaksTextBoxPage 23/29
dpeaksTextBoxAT2T-3238-1 Rev.C ACCU-STEAMTM GAS GRIDDLE OWNERS MANUAL
Unl
ess
othe
rwis
e sp
ecifi
ed,
D
imen
sion
s: I
nche
s
Ben
ds: 9
0
Tol
eran
ces:
Ang
ular
1
2 P
lace
Dec
imal
.0
2
3
Pla
ce D
ecim
al
.005
T.I.
R
.005
12
5 M
icro
Inch
esG
D&T
Per
AN
SI Y
14.5
M
AT2
A-2
850-
2G
AS
CO
NTR
OL
VALV
E A
SSEM
BLY
PR
OPA
NE
OTH
ERW
ISE
SAM
E A
S A
T2A
-285
0-1
1112
A
AB
B
16
7
4
3
13
105
12
2
8
9
11
9
2
14
CC
C
C
DD
AT2
A-2
850-
2G
AS
CO
NTR
OL
VALV
E A
SSEM
BLY
PR
OPA
NE
QTY
AT2
A-2
850-
2Q
TYA
T2A
-285
0-1
PAR
T N
O.
ITEM
NO
.D
ESC
RIP
TIO
N
11
AT0
F-32
22-2
1025
14SC
REW
, PH
ILLI
PS P
AN
HEA
D #
6-32
TYP
E F
1/4"
11
AT2
E-20
87-1
13M
AIN
BU
RN
ER V
ALV
E
1-
AT0
P-28
47-2
12PR
ESSU
RE
REG
ULA
TOR
, PR
OPA
NE
GA
S
-1
AT0
P-28
47-1
12PR
ESSU
RE
REG
ULA
TOR
, NA
TUR
AL
GA
S
1-
AT2
E-18
06-3
11C
ON
TRO
L VA
LVE,
GA
S 10
" W
.C. P
RO
PAN
E G
AS
-1
AT2
E-18
06-2
11C
ON
TRO
L VA
LVE,
GA
S 5"
W.C
. NA
TUR
AL
GA
S
11
AT0
P-28
58-1
10TE
E M
ALE
BR
AN
CH
22
AT0
P-28
49-3
9ST
REE
T EL
BO
W 9
0
11
AT0
P-28
48-1
8R
EDU
CIN
G H
EX N
IPPL
E
11
AT0
P-28
45-1
7M
ALE
CO
NN
ECTO
R
11
AT0
P-28
43-1
6U
NIO
N B
LAC
K IR
ON
PIP
E
11
AT0
P-30
24-2
5PL
UG
CO
UN
TER
SUN
K H
EX H
EAD
11
AT2
M-2
838-
14
BR
KT
GA
S R
EGU
LATO
R
11
AT0
P-20
96-2
3EL
BO
W 9
0 C
OM
PRES
SIO
N
22
AT0
P-20
91-4
2C
LOSE
NIP
PLE
PIPE
11
AT0
P-20
89-4
1EL
BO
W, S
TREE
T 90
EC
NREV.
DESCRIPTION
DATE
APPRO
VED
RE
VIS
ION
S
344
DC
HG
'D: I
TEM
#14
AT0
F-32
22-2
1025
WA
S A
T0F-
2773
-21
022
05-21-07
LEC/ALB
188
CR
MV
D: I
TMN
O 6
AT0
P-2
841-
1, C
HG
D: B
OM
/BA
LLO
ON
E
RR
OR
, ITM
NO
11
WA
S 1
2,A
DD
ED
: ITM
NO
5 A
T0P
-30
24-2
12-21-04
GLS/AP
152
BC
HG
D A
T0F-
2773
-210
22 W
AS
AT0
F-31
030
10-5-04
GLS/ALB
101
AA
DD
ED
: ITE
M 1
405-07-04
GLS
EDR
: 045
ESc
ale:
1:1
Shee
t 1 o
f 1
D
Title
:
Rev
.D
raw
ing
No.
:Si
ze:
AT2
A-2
850
D
GA
S C
ON
TRO
L VA
LVE
ASS
EMB
LY
Acc
uTem
p Pr
oduc
ts, I
nc.
8415
N. C
linto
n Pa
rkFo
rt W
ayne
, IN
468
25
Nam
eD
ate
Dra
wn
Che
cked
Proj
ect E
ng
Do
Not
Sca
le D
raw
ing
Fini
sh:
N/A
Mat
eria
l:
Com
men
ts:
ALB
03-2
5-04