32
AC Inverter Drives

AC Inverter Drives - Baviskar Sales & Service, Ahmedabad · AC Inverter Drives. The New 1000 Series AC Drives J1000, ... times faster than other drives, which improves motor control

Embed Size (px)

Citation preview

AC Inverter Drives

The New 1000 Series AC Drives

J1000, V1000 & A1000

AC Drives are manufactured by :

YASAKAWA Electric Corporation

JAPAN

The New Generation Drives are

factory-programmed and ready to

run. J1000, V1000 & A1000 drives

have standard LED display. The

keypad is intuitive and includes

parameter-copying functions to

copy parameters from one drive to

another.Displayextension isoptional

for J1000 and V1000.

L&T offers a range of performance

choices and innovative technologies.

Control methods include V/f, open

loop vector and closed loop vector

control for speed regulation choices.

These can run induction as well as

PermanentMagnetmotors.

Performance and Technology

Larsen & Toubro’s New 1000 series AC

Drives incorporate the latest technological

advancements in AC

motor speed control.

This support tool is a windows based

PC program designed to make

commissioning and troubleshooting

of these drives as simple as

possible. The user friendly Drive

Wizard exchanges data with drive

and data can be retrieved, reviewed,

changed, stored and graphed.

Commissioning Software:

Drive Wizard

• MTBF: Exceeds 28 years

• Tested on fully-loaded motors

• Surface mount technology

• Protective PCB coating

• 0.6G or less (20 to 55Hz)

• and listed

• RoHS compliant

Standards & Reliability

Torque limit

Heat sink over-heat to give overload protection to inverter

Motor overload protection

Phase-to-phase, ground fault and short circuit protection

Over/under torque protection

Input/output single phasing protection

Optically-isolated controls: to completely isolate control circuit from power circuit

Protection

1

L&T SWITCHGEAR

S A F E & S U R E

Low noise operation

High starting torque

High slip breaking

Volts/Frequency ratio: fullyadjustable

Kinetic energy buffering

Over-voltage suppression

Drive efficiency: 96 to 98%

Output frequency: 1.0 to 400 Hz

Torque boost: full range

Auto carrier reduction

Performance Monitors

Performance Features

Digital keypad operator

Copy keypad function

24 VDC control logic for sourcing sourcing outputs (both PNP or NPN transistors)

RJ-45 style digital operator connector

Multi speed settings plus jog speed

Flash RAM software memory for update

Split front cover for easy wiring

Heat sink fan: Plug-in with on-offcontrol

Functions

Salient Features ofJ1000, V1000 & A1000 Drives

The J1000 series offers ultimate

ease of use, portability and

opt ions for wide ranging

applications.

With this series, L&T brings

international standard inverter

drive that meet all automation

requirements for compact

applications with variable speed

operation and energy saving

characteristics. A wide range of

useful functions upgrade your

machine and offer greater

potential.

The concept of small size and

easy handling makes the J1000 a

handy alternative in the drive

m a r k e t n o t o n l y f o r i t s

performance but also for

economy of cost.

• Conveyor

• Pump

• Grinder

• Hoist

• Crane

• Screw Feeder

• Escalator

• Fan

• Elevator (door)

Common Applications

V/f Control

Plug’n Play installation function

High flux braking function

Easy parameter programmingand controller functions

Braking Chopper built-in

Heavy duty / normal duty rating

9 step speed

Slip compensation

Speed search

Momentary power log the ride through

Features

2

Micro Size OEM DriveJ1000

L&T SWITCHGEAR

S A F E & S U R E

J10

00

3

Specifications

Co

ntr

olF

un

ctio

ns

Fu

nctio

na

lity

Pro

tection

Functio

ns

Control methods V/f Control

Starting Torque 150%/3Hz

Speed Control Range 1:20~1:40 (V/f control)

Output frequency Range 0.01 Hz to 400 Hz

Frequency Reference Digital set value: ±0.01% (-10..+50°C)Accuracy Analogue set value: ±0.5% (25±10°C)

Resolution of frequency Digital set value: 0.01 Hz (<100Hz), 0.1 Hz (>100 Hz)Analogue set value: 1/1000 of maximum frequency (10 bit)

Resolution of output frequency 0.001 Hz

Heavy duty use: 150% rated output current for one minuteOverload capability Normal duty use: 120% rated output current for one minute

V/f Characteristics Preset V/f patterns and user-set program available

Analogue Inputs 1 analogue input: 0..10 V (20kÙ) at 0/4..20 mA (250kÙ)

Analogue Outputs 1 analogue output: 0..10V

Deceleration/acceleration times 0.01 Sec. to 6000 s

5 digit, 7 Segment LEDDisplay Error and status LED

Motor overload protection Motor overheat protection via output current sensor

Instantaneous overcurrent Drive stops when output exceeds 200% of the rated current (Heavy Duty)

Overload Heavy duty: A stop command will be entered after operative at 150% for 60 secNormal duty: A stop command will be entered after operative at 120% to 60 sec

Overvoltage Motor coasts to a stop if DC Bus voltage exceeds 820V for 400V class (410V for 200V class)

Drive stops when DC Bus voltage falls below following levels:Undervoltage 190V (3-phase 200V), 160V (Single-phase 200V), 380V (3-phase 400V)

Momentary power loss Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power returns within set time, Drive will restart if power returns as long as the CPU is working.

Cooling fin overheat Protected by thermistor

Stall prevention level Stall prevention is available during acceleration, deceleration and during run. type of stall prevention determine the current level at which stall prevention is triggered.

Ground fault Protected by electronic circuit (triggered by the same level as momentary current protection)

Degree of Protection IP20, NEMA1 available as an option

Ambient humidity 95% RH or less (without condensation)

Storage temperature -20°C to +60°C (short-term temperature during transportation)

Installation Indoor (no corrosive gas, dust, etc.)

Installation height Max. 1000 m (output derating of 1% per 100 m above 1000 m, max. 3000 m)

Vibration Up to 1G at 10 to 20 Hz, Up to 0.6G at 20 to 55 Hz

Setting

set value

Separate settings for each

Am

bie

ntC

on

ditio

ns

COMMON SPECIFICATIONS

200-240V Single Phase 50/60Hz

Output Current (A)

(kW)

Application Motor Capacity ND

0.75

4.1

3.4

1.5 2.2

1.5

5.4

4.8

HD

HD

ND

380-480V Three Phase 50/60 Hz

4A0004 4A0005

3.0

2.2

6.9

5.5

4A0007

3.7

3.0

8.8

7.2

4A0009

5.5

3.7

11.1

9.2

4A00011Model CIMR-JT_ _ _ _ _ _ _ _ _BAA

Application Motor Capacity

Output Current (A)

HD(kW)

HD

ND

ND 0.75

0.4

3.3

3.0

BA0003

1.1

0.75

6.0

5.0

BA0006

2.2

1.5

9.5

8.0

BA0010Model CIMR-JT_ _ _ _ _ _ _ _ _BAA

The V1000 drive is incredibly

compact, technologically advanced,

env i ronmenta l ly respons ib le

package capable of driving induction

as well as synchronous motor. With

its preset application function and

dual rating it can handle wide variety

of application ranging from Fan,

Pump Compressor, Elevator, Crane

Conveyor and many more. V1000

employs dual CPU concept that is 4

times faster than other drives, which

improves motor control performance

especia l ly in vector contro l

applications. Custom software,

network communications, plugin I/O

cards, packaging options as among

the many choices. V1000 with its

highly advanced features stands out

in its class and a perfect solutions for

most of your applications.

• Pump

• Fan

• HVAC (AHU)

• Conveyor

• Air Compressor

• Crane Hoist

• Crane (Travel)

• Elevator

• Packaging machines

• Extruders

• Centrifuge

Compact Current

Control Vector Drive

Normal & Heavy Duty

V1000

4

Common Applications Features

10 years performance life design

Normal Duty and Heavy Duty selection depending on the application

Single drive for both Induction &permanent magnet motors

Drive customization / PLC functionality

Dual microprocessor for faster control

Rotation & Static Auto-tuning

On-line Auto-tuning

200% starting torque

Allows side by side mounting-reduces panel space

High flux braking for faster stopping without use of braking resistors

Intelligent detachable terminal block

Stores last 10 faults

High speed serial communication at 115kbps

Optional LCD operator

L&T SWITCHGEAR

S A F E & S U R E

*1: Drives with a single-phase power supply input have Three-phase output and cannot be used for single phase motors.

*2: Based on a standard 4-pole motor for max. applicable motor output.

Note: Value inside parenthesis is for a single-phase drive.

200 V Class (Three-phase/Single-phase)

Normal Duty

Heavy Duty

Normal Duty

Heavy Duty

Normal Duty

Heavy Duty

Normal Duty

-

18.5

15.0

85.6

70.8

-

-

26.3

Heavy Duty 22.9

Normal Duty 69.0

Heavy Duty 60.0

Model

0.75

0.4

3.9

2.9

7.3

5.5

1.3

0003

1.1

3.5(3.3)

3.0

0004

1.1

0.75

7.3

5.8

13.8

11.0

2.3

0006

1.9

6.0

5.0

0006

2.2

1.5

10.8

7.5

20.2

14.1

0010

3.7

3.0

9.6

8.0

0010

5.5

3.7

24.0

18.9

-

35.0

0018

7.5

6.7

19.6

17.5

0020

7.5

5.5

34.7

26.0

-

-

-

11.4

9.5

30.0

250

0030

11.0

7.5

50.9

35.4

-

-

-

15.2

12.6

40.0

33.0

0040

15.0

11.0

69.4

51.9

-

-

-

21.3

17.9

56.0

47.0

0056 0069Three-Phase CIMR-VT2A*1

Single-Phase CIMR-VTBA

Max. Applicable Motor*2

Capacity (kW)

Inp

ut

Rated InputCurrent (A)

Rated OutputCapacity (kVA)

Three-Phase

Single-Phase

Ou

tpu

t

Rated Output Current (A)

Overload Tolerance

3.0

2.2

13.9

11.0

24.0

20.6

0012

4.6

4.2

12.0

11.0

0012

2 kHz (user-set, up to 15 kHz possible)

Three-Phase Power Supply: Three-Phase 200 to 240 V (relative to input voltage)

Single-Phase Power Supply: Three-Phase 200 to 240 V (relative to input voltage)

400 Hz

Three-Phase Power Supply: Three-Phase 200 to 240 V 50/60 Hz

Single-Phase Power Supply: Single-Phase 200 to 240 V 50/60 Hz

- 15 to 10%

±5%

Carrier Frequency

Max. Output Voltage

Max. Output Frequency 400 Hz

Po

we

r Rated Voltage/Rated Frequency

Allowable Voltage Fluctuation

Allowable Frequency Fluctuation

Normal Duty Rating: 120% of rated output current for 60 sec

Heavy Duty Rating: 150% of rated output current for 60 sec

400 V Class (Three-phase)

*1: Based on a standard 4-pole motor for max. applicable motor output.

Rated Output Current (A)

Max. Applicable Motor*1

Capacity (kW)

Normal Duty

Heavy Duty

Normal Duty

Heavy Duty

Normal Duty

Heavy Duty

Normal Duty

Heavy Duty

0002

0.75

0.4

2.1

1.8

1.6

1.4

2.1

1.8

0004

1.5

0.75

4.3

3.2

3.1

2.6

4.1

3.4

0005

2.2

1.5

5.9

4.4

4.1

3.7

5.4

4.8

0007

3.0

2.2

8.1

6.0

5.3

4.2

6.9

5.5

0009

3.7

3.0

9.4

8.2

6.7

5.5

8.8

7.2

0011

5.5

3.7

14.0

10.4

8.5

7.0

11.1

9.2

0018

7.5

5.5

20.0

15.0

13.3

11.3

17.5

14.8

0023

11.0

7.5

24.0

20.0

17.5

13.7

23.0

18.0

0031

15.0

11.0

38.0

29.0

23.6

18.3

31.0

24.0

0038

18.5

15.0

44.0

39.0

29.0

23.6

38.0

31.0

Model CIMR-VT4A

Input Rated Input Current (A)

Rated OutputCapacity (kVA)

Outp

ut

Overload Tolerance Normal Duty Rating: 120% of rated output current for 60 sec

Heavy Duty Rating: 150% of rated output current for 60 sec

2 kHz (user-set, up to 15 kHz possible)

Three-Phase 380 to 480 V (relative to input voltage)

400 Hz (user-set)

Three-Phase 380 to 480 V 50/60 Hz

- 15 to 10%

±5%

Carrier Frequency

Max. Output Voltage

Max. Output Frequency

Po

we

r

Rated Voltage/Rated Frequency

Allowable Voltage Fluctuation

Allowable Frequency Fluctuation

V1

00

0

5

STANDARD SPECIFICATIONS

COMMON SPECIFICATION

200%/0.5 Hz

50%/6 Hz

Open Loop Vector Control (Current Vector), V/f Control, PM Open Loop Vector Control (for SPM and IPM motors)

Momentary power loss ride-thru, Speed search, Over torque detection, Torque limit, 17-step speed (max),

Accel/Decel time switch, S-Curve accel/decel, 3-wire sequence, Auto-Tuning (Rotational, Stationary tuning

for resistance between lines), Cooling fan on/off switch, Slip compensation, Torque compensation,

Frequency jump, Upper/Lower limits for frequency reference, DC lnjection braking at start and stop, High slip

braking, PID control (With sleep function), Energy saving Control, Memobus comm. (RS-485/422 max 115.2 kbps),

Fault restart, Application presets, Removable terminal block with parameter backup function

Motor overheat protection based on output current, Momentary over-current protection, Overload p , Over-voltage

protection, Undervoltage protection, Momentary power loss ride-thru, Heatsink oveheat,

Braking resistance overheat protection, Stall prevention, Ground fault protection

rotection

6

L&T SWITCHGEAR

S A F E & S U R E

V1

00

0

7

MODEL SELECTION BY MOTOR CAPACITY

Normal Duty : 120% Overload for 1 min on inverter rated output current.Application : Fans, pumps, variable torque load and application which do not require high overload

Heavy Duty : 150% overload for 1 min on inverter rated output current.Application : Constant torque or impact load, like elevater, crane, compressor,

Centrifuges and mixers with high viscosity material

3PH 415V INPUT

3 PH 220V INPUT

CIMR-VT4A0002BAA 0.4 1.8 1.4 0.75 2.1 1.6

CIMR-VT4A0004BAA 0.75 3.4 2.6 1.5 4.1 3.1

CIMR-VT4A0005BAA 1.5 4.8 3.7 2.2 5.4 4.1

CIMR-VT4A0007BAA 2.2 5.5 4.2 3.0 6.9 5.3

CIMR-VT4A0009BAA 3.0 7.2 5.5 3.7 8.8 6.7

CIMR-VT4A0011BAA 3.7 9.2 7.0 5.5 11.1 8.5

CIMR-VT4A0018FAA 5.5 14.8 11.3 7.5 17.5 13.3

CIMR-VT4A0023FAA 7.5 18.0 13.7 11.0 23.0 17.5

CIMR-VT4A0031FAA 11.0 24.0 18.3 15.0 31.0 23.6

CIMR-VT4A0038FAA 15.0 31.0 23.6 18.5 38.0 29.0

CIMR-VT2A0004BAA 0.4 3.0 1.1 0.75 3.3 1.3

CIMR-VT2A0006BAA 0.75 5.0 1.9 1.1 6.0 2.3

CIMR-VT2A0008BAA 1.1 6.9 2.6 1.5 8.0 3.0

CIMR-VT2A0010BAA 1.5 8.0 3.0 2.2 9.6 3.7

CIMR-VT2A0012BAA 2.2 11.0 4.2 3.0 12.0 4.6

CIMR-VT2A0018BAA 3.0 14.0 5.3 3.7 17.5 6.7

CIMR-VT2A0020BAA 3.7 17.5 6.7 5.5 19.6 7.5

CIMR-VT2A0030FAA 5.5 25.0 9.5 7.5 30.0 11.4

CIMR-VT2A0040FAA 7.5 33.0 12.6 11.0 40.0 15.2

CIMR-VT2A0056FAA 11.0 47.0 17.9 15.0 56.0 21.3

CIMR-VT2A0069FAA 15.0 60.0 22.9 18.5 69.0 26.3

MODEL Heavy Duty Normal Duty

kW Amps KVA kW Amps KVA

Common Applications

• Conveyors

• Mixers

• Machine tools

• Cut-to-length

• Centrifugal Pumps

• Centrifuges

• Extruders

• Packaging Machines

• HVAC

• Fan

• Compressor

10 years performance life design

Uses most advanced drive

technology to run induction and

synchronous motors

Positioning accuracy without use

of external sensors

Excellent torque characteristics

Loaded with new auto-tuning

features

Tackles power loss

Easy setup with application

presets

Open to all serial network

protocols

Easy to maintain

10 years performance life design

Environment friendly

Features

8

Industrial WorkhorseFor Induction and PermanentMagnet Product

A1000

L&T A1000 drives with its latest

vector control technology is capable

o f d e l i v e r i n g h i g h e r o r d e r

performance to meet customer

expectations. A1000, not only

performs but is aesthetically superior

and incredibly powerful. A truly

reliable product to address future

requirements & current needs, only

possible from L&T.

L&T SWITCHGEAR

S A F E & S U R E

A1

00

0

STANDARD SPECIFICATIONS

9

Optional

Optional

OPTIONS, PERIPHERAL DEVICES

10

Applied to further improve thepower factor of the inverter.

The Varispeed A1000 incorporatesDC Reactor on model of 22kW

or more.

OutputReactor

SemiconductorFuse

Accessories

Type Cat. Nos. Function

Complementry

PG cardPG-B3

Line DriverPG card PG-X3

CommunicationOption Cards

SI-P3

SI-P3/V

SI-N3

SI-N3/V

SI-C3 CC-Link interface card

CAN open interface card

MECHTOLINK-II interface card

Memobus / modbus interface card

Digital LCD operator display

USB Copy unit for copy & verifyfunctions

SI-S3

SI-T3

SI-485/J

JVOP-180

JVOP-181

For speed feedback input by connecting a motor encoder Input: 3 track (can be used with one or two tracks), for HTL encoder connection, 50 kHz max; Output: 3 track, open collector Encoder power supply: 12 V, max current 200 mA

For speed feedback input by connecting a motor encoder Input: 3 track (can be used with one or two tracks), line driver, 300 kHz max; Output: 3 track, line driver Encoder power supply: 5 V or 12 V, max current 200 mA

Profibus-DP interface cards

DeviceNet interface cards

Applicable For

A1000

A1000

A1000

V1000

A1000

V1000

A1000

J1000

V1000 & A1000

L&T SWITCHGEAR

S A F E & S U R E

Dyanamic Braking Unit (DBU) Dynamic Braking Resistance (DBR)Motor(kW)

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

185

220

250

315

355

ND/HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

Drive Model

CIMR-VT4A*******CIMR-AD4A*******

CIMR-JT4A*******CIMR-VT4A*******CIMR-AD4A*******

CIMR-VT4A*******CIMR-AD4A*******

CIMR-AD4A*******

CDBR-4045

Cat. No.

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

CDBR-4045

CDBR-4045

CDBR-4045

CDBR-4030

CDBR-4030

CDBR-4045

CDBR-4220

CDBR-4220

CDBR-4220

CDBR-4220

CDBR-4220

CDBR-4220

CDBR-4220

CDBR-4220

Quantity

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1

1

1

2

2

2

1

1

1

1

1

1

2

2

70

70

260

260

390

520

780

1040

1560

4800

4800

6000

6000

9600

9600

9600

6000

6000

9600

9600

6000

9600

9600

9600

9600

9600

9600

9600

750

750

400

250

150

100

75

50

40

32

27.2

20

20

16

13.6

13.6

20

20

13.6

13.6

20

13.6

13.6

13.6

16

16

13.6

13.6

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

3

4

4

4

5

5

6

8

DBU & DBR selection Chart for400V J1000 / V1000 / A1000 AC drives

Note:1) Duty factor = 10% ED, for 10 seconds only; This chart is not applicable for Hoist / Elevator motions2) DBU shall be purchased from L&T however DBR of given values must be purchased from local vendors 3) ND = Normal Duty ; HD = Heavy Duty

11

Op

tio

ns

&A

cce

sso

rie

s

12

Guideline For Panel ComponentSelection : A1000/V1000/J1000 Drive

Note:1) For any other make for fuses, kindly insure pre-arc I ^ 2 t value mentioned in the bracket.2) Motor kW refers to a 4-pole motor. Rated output current of drive should be equal to or greater than the motor rated current.3) DN3-630S TM for 185 & 22kW motor is thermal-magnetic realease dsine MCCB.4) Panel Fan EBM make : 115W.5) Either use input AC choke or use DC choke upto CIMR-AD4A0044FMA models, V1000 and J1000 models.

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

185

220

250

315

355

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

HD

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

Cat. No.for

kWMotor

A1000 AC Drive / Inverter / VFD / VFSD/

VVVF Drive

DriveRated

Amp @ 50°C

IncomerMCCB

SemiconductorInput Fuse: 3 quantity

Bussmann(Pre-arc I^2t)

DM16/5 Amp

DM166.3 Amp

DM167.5 Amp

DM1610 Amp

DM1616 Amp

DM10025 Amp

Chokes

I/P ACchoke DC choke

O/PChoke

PanelFanQty.

uH/A uH/A uH/A

HD/ND

Type

CIMR-AD4A0002FMA

CIMR-AD4A0002FMA

CIMR-AD4A0004FMA

CIMR-AD4A0004FMA

CIMR-AD4A0005FMA

CIMR-AD4A0005FMA

CIMR-AD4A0007FMA

CIMR-AD4A0007FMA

CIMR-AD4A0011FMA

CIMR-AD4A0011FMA

CIMR-AD4A0018FMA

CIMR-AD4A0018FMA

CIMR-AD4A0023FMA

CIMR-AD4A0023FMA

CIMR-AD4A0031FMA

CIMR-AD4A0031FMA

CIMR-AD4A0038FMA

CIMR-AD4A0038FMA

CIMR-AD4A0044FMA

CIMR-AD4A0044FMA

CIMR-AD4A0058AMA

CIMR-AD4A0058AMA

CIMR-AD4A0072AMA

CIMR-AD4A0072AMA

CIMR-AD4A0088AMA

CIMR-AD4A0088AMA

CIMR-AD4A0103AMA

CIMR-AD4A0103AMA

CIMR-AD4A0139AMA

CIMR-AD4A0139AMA

CIMR-AD4A0165AMA

CIMR-AD4A0165AMA

CIMR-AD4A0208AMA

1.80 FWH-40B (76)

2.10 FWH-40B (76)

3.40 FWH-50B (135)

4.10 FWH-50B (135)

4.80 FWH-70B (210)

5.40 FWH-70B (210)

5.50 FWH-70B (210)

6.90 FWH-70B (210)

9.20 FWH-90B (360)

11.10 FWH-90B (360)

14.80 FWH-80B (305)

17.50 FWH-80B (305)

18.00 FWH-100B (475)

23.00 FWH-100B (475)

24.00 FWH-125B (800)

31.00 FWH-125B (800)

31.00 FWH-200B (1900)

38.00 FWH-200B (1900)

39.00 FWH-250A (6300)

44.00 FWH-250A (6300)

45.00 FWH-250A (6300)

58.00 FWH-250A (6300)

60.00 FWH-250A (6300)

72.00 FWH-250A (6300)

75.00 FWH-250A (6300)

88.00 FWH-250A (6300)

91.00 FWH-250A (6300)

103.00 FWH-250A (6300)

112.00 FWH-350A (14500)

139.00 FWH-350A (14500)

150.00 FWH-400A (19200)

165.00 FWH-400A (19200)

180.00 FWH-500A (29200)

CIMR-AD4A0208AMA 208.00 FWH-500A (29200)

CIMR-AD4A0250AMA 216.00 FWH-600A (41300)

CIMR-AD4A0250AMA 250.00 FWH-600A (41300)

CIMR-AD4A0296AMA 260.00 FWH-700A (55000)

CIMR-AD4A0296AMA 296.00 FWH-700A (55000)

CIMR-AD4A0362AMA 304.00 FWH-800A (76200)

CIMR-AD4A0362AMA 362.00 FWH-800A (76200)

CIMR-AD4A0414AMA 370.00 FWH-800A (76200)

CIMR-AD4A0414AMA 414.00 FWH-800A (76200)

CIMR-AD4A0515AMA 450.00 FWH-1000A (92000)

CIMR-AD4A0515AMA 515.00 FWH-1000A (92000)

CIMR-AD4A0675AMA 605.00 FWH-1200A (122000)

CIMR-AD4A0675AMA 675.00 FWH-1200A (122000) 31/800

18000/2

18000/2

8400/4

8400/4

4200/5.5

4200/5.5

3600/7.5

3600/7.5

2200/10

2200/10

1420/15

1420/15

1060/20

1060/20

700/30

700/30

530/40

530/40

420/50

420/50

360/60

360/60

260/80

260/80

240/90

240/90

180/120

180/120

150/150

150/150

110/200

110/200

90/250

90/250

90/250

90/250

60/330

60/330

60/330

60/330

40/490

40/490

40/490

40/490

30/660

30/660

28000/3.2

28000/3.2

28000/3.2

28000/3.2

11000/5.7

11000/5.7

11000/5.7

11000/5.7

6300/12

6300/12

3600/23

3600/23

3600/23

3600/23

1900/33

1900/33

1900/33

1900/33

1300/47

1300/47

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

Built In

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

2

3

3

3

3

4

4

8072/2

8072/2

6538/4.2

6538/4.2

3710/5.5

3710/5.5

2446/7

2446/7

1899/12

1899/12

1076/18

1076/18

807/25

807/25

538/35

538/35

448/38

448/38

359/45

359/45

294/60

294/60

231/70

231/70

190/85

190/85

161/100

161/100

115/140

115/140

90/180

90/180

77/216

77/216

67/240

67/240

50/320

50/320

45/360

45/360

34/475

34/475

26/630

26/630

31/800

DM10025 Amp

DM10035 Amp

DM10050 Amp

DM10050 Amp

DM10070 Amp

DM10080 Amp

DN2-250M100 Amp

DN2-250M125 Amp

DN2-250M160 Amp

DN2-250M250 Amp

DN2-250M250 Amp

DN3-400M320 Amp

DN3-400M400 Amp

DN3-400M400 Amp

DTH800800 Amp

DN3-630S TM630 Amp

DN3-630S TM630 Amp

DTH800/800A

L&T SWITCHGEAR

S A F E & S U R E

Op

tio

ns

&A

cce

sso

rie

s

13

Dimensions & WeightsJ1000 Drive

Max Application Motor Capacity(kW) Dimensions(mm)Voltage Class Model No. Weight Cooling

Heavy Duty Normal Duty W H D

CIMR-JT4A0004BAA 0.75 1.50 138

400V ClassCIMR-JT4A0005BAA 1.50 2.20 108 3.80

154128Three PhaseCIMR-JT4A0007BAA 2.20 3.00

Self

CIMR-JT4A0011BAA 3.70 5.50 140 143 5.3Cooling

CIMR-JTBA0003BAA 0.40 0.75 68 118 2.2200V Class

CIMR-JTBA0006BAA 0.75 1.50 138 3.8128Single Phase 108

CIMR-JTBA0010BAA 1.50 2.20 154 4

Figure 1

Open-Chassis (IP20)

Notes:(a) All Dimension in mm.(b) For more technical details on heat sink and all please refer the manual.

14

DimensionsV1000 Drive

& Weights

Enclosures

Notes:(a) All Dimension in mm.(b) For more technical details on heat sink and all please refer the manual.

Max Application Motor Capacity(kW) Dimensions(mm)Voltage Class Model No. Weight Cooling

Heavy Duty Normal Duty W H D

CIMR-VT4A0002BAA 0.4 0.75 99 1.2

CIMR-VT4A0004BAA 0.75 1.5 137.5

CIMR-VT4A0005BAA 1.5 2.2 1081.7128

154CIMR-VT4A0007BAA 2.2 3400V Class

CIMR-VT4A0009BAA 3 3.7Three Phase

CIMR-VT4A0011BAA 3.7 5.5 143 2.4

140CIMR-VT4A0018FAA 5.5 7.5254 140 3.8

CIMR-VT4A0023FAA 7.5 11

CIMR-VT4A0031FAA 11 15 180 290 143 5.2

CIMR-VT4A0038FAA 15 18.5 163 5.5 Self

CIMR-VT2A0004BAA 0.4 0.75 68 149.5 108 0.9 Cooling

CIMR-VT2A0006BAA 0.75 1.5 137.5 1.1108

CIMR-VT2A0010BAA 1.5 2.2 154128 1.7

CIMR-VT2A0012BAA 2.2 3 163200V Class140

CIMR-VT2A0020BAA 3.7 5.5 143 2.4Three Phase

CIMR-VT2A0030FAA 5.5 7.53.8140 254 140

CIMR-VT2A0040FAA 7.5 11

CIMR-VT2A0056FAA 11 15 180 290 163 5.5

CIMR-VT2A0069FAA 15 18.5 220 350 187 9.2

L&T SWITCHGEAR

S A F E & S U R E

Dim

en

sio

ns

&W

eig

hts

15

CIMR-AD4A0002FMA

CIMR-AD4A0004FMA

CIMR-AD4A0005FMA

CIMR-AD4A0007FMA

CIMR-AD4A0011FMA

CIMR-AD4A0018FMA

CIMR-AD4A0023FMA

CIMR-AD4A0031FMA

CIMR-AD4A0038FMA

CIMR-AD4A0044FMA

CIMR-AD4A0058AMA

CIMR-AD4A0072AMA

CIMR-AD4A0088AMA

CIMR-AD4A0103AMA

CIMR-AD4A0139AMA

CIMR-AD4A0165AMA

CIMR-AD4A0208AMA

CIMR-AD4A0250AMA

CIMR-AD4A0296AMA

CIMR-AD4A0362AMA

CIMR-AD4A0414AMA

CIMR-AD4A0515AMA

CIMR-AD4A0675AMA

0.75

1.5

2.2

3.0

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

185

220

250

355

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

185

220

315

140

140

180

220

250

275

325

325

450

500

500

670

260

260

300

350

400

450

510

550

705

800

950

1140

147

164

167

187

197

258

258

283

330

350

370

3.2

3.4

3.5

3.9

5.4

5.7

8.3

21

25

36

41

42

79

96

102

107

125

221

Self

cooling

Fan

cooling

Max. Application Motor Capacity (kw)

Normal Duty Heavy Duty

ModelCIMR-AD4A

Dimensions (mm)

W H D

Weight(kg) Cooling

400 V Class

DimensionsA1000 Drive

& Weights

Notes:(a) All Dimension in mm.(b) For more technical details on heat sink and all please refer the manual.

General Information

An AC or DC reactor should be installed in the following conditions:

• to suppress harmonic currents.

• to suppress peak currents when power factor correction capacitors in the power supply network are

switched.

• when the drive is connected to the same power supply system with thyristor converters like DC

drives.

When running a specialized motor or more than one motor in parallel from a single drive, the capacity

of the drive should be larger than 1.1 times of the total motor rated current.

Terminals B1, B2, F, +1, +2, - are provided for connecting optional features for the drive. Do not

connect other equipment designed by other manufacturers.

Acceleration / deceleration times are affected by how much torque the motor generates the load

torque.

Never connect the power supply lines to output terminals U/T1, V/T2 or W/T3. Doing so will destroy

the drive. Be sure to perform a final check of all sequence wiring and other connections before turning

the power on. Make sure there are no short circuits on the control terminals (+V, AC, etc.), as this

could damage the drive.

As a general principle, the user should avoid opening and closing the magnetic contactor between

the motor and the drive during run. Doing so can cause high peak currents and over current faults. If

magnetic contactors are used to bypass the drive by connecting the motor to the power supply

directly, make sure to close the bypass not before the drive is stopped and fully disconnected from the

motor. If the motor start running even while coasting, select the speed search functions. Set up

delayed release when using a magnetic contactor to handle momentary power loss.

In case of submersible motor, since rated current is greater than a standard motor, select the drive

capacity accordingly. Be sure to use a large enough motor cable to avoid decreasing the maximum

torque level on account of voltage drop caused by a long motor cable.

Variable speed drives are not designed for operating single phase motor. Using a capacitor to start

the motor causes excessive current to flow into the capacitor, potentially causing damage. A slit-

phase start or a repulsion start can end up burning out the starting coils because the internal

centrifugal switch is not activated. The drive can only be used with three phase motors.

16

L&T SWITCHGEAR

S A F E & S U R E

Pro

du

ct

Ra

ng

e

17

Industrial AutomationProduct Range

Programmable Logic Controllers

(PLCs)

AC Inverter Drives Softstarters

Servo Drives

Human Machine Interface

LnTOR - DC DrivesProgrammable

Smart Relay - Lµ 1000

REGISTERED OFFICE ANDHEAD OFFICEL&T House, Ballard EstateP. O. Box 278Mumbai 400 001Tel: 022-67525656Fax: 022-67525858Website: www.Larsentoubro.com

ELECTRICAL STANDARD PRODUCTS (ESP)501, Sakar Complex IOpp. Gandhigram Rly. Station Ashram RoadAhmedabad 380 009Tel: 079-66304007-11Fax: 079-26580491 / 66304025e-mail: [email protected]

38, Cubbon Road, P. O. Box 5098Bangalore 560 001Tel: 080-25020100Fax: 080-25580525e-mail: [email protected]

131/1, Zone IIMaharana Pratap NagarBhopal 462 011Tel: 0755-4098721 / 7 / 8 / 9Fax: 0755-2769264e-mail: [email protected]

Plot No. 559, Annapurna ComplexLewis RoadBhubaneswar 751 014Tel: 0674-6451342, 2436696Fax: 0674-2537309e-mail: [email protected]

SCO 32, Sector 26-D Madhya Marg, P. O. Box 14Chandigarh 160 026Tel: 0172-4646840, 4646853Fax: 0172-4646802e-mail: [email protected]

10, Club House RoadChennai 600 002Tel: 044-28462072 / 4 / 5 / 2109Fax: 044-28462102 / 3 e-mail: [email protected]

67, Appuswamy RoadPost Bag 7156 Opp. Nirmala CollegeCoimbatore 641 045Tel: 0422-2588120 / 1 / 5Fax: 0422-2588148e-mail: [email protected]

Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.

Electrical Standard Products (ESP) Branch Offices:

L&T House, Group MIG-5 PadmanabhpurDurg 491 001Tel: 0788-2213833 / 14 / 21 / 29Fax: 0788-2213820

Khairasol, Degaul AvenueDurgapur 713 212Tel: 0343-2559848 / 2559849 / 2559844Fax: 0343-2553614e-mail: [email protected]

Milanpur Road, Bamuni MaidanGuwahati 781 021Tel: 0361-2550568Fax: 0361-2551308e-mail: [email protected]

II Floor, Vasantha Chambers5-10-173, Fateh Maidan RoadHyderabad 500004Tel: 040-66720250Fax: 040-23296468e-mail: [email protected]

D-24, Prithvi Raj Road, C-SchemeJaipur 302 001Tel: 0141-2385915 / 16 / 17 / 18Fax: 0141-2373280e-mail: [email protected]

Akashdeep Plaza, 2nd Floor P. O. GolmuriJamshedpur 831 003JharkhandTel: 0657-2340864 / 387Fax: 0657-2341250e-mail: [email protected]

Skybright Bldg; M. G. RoadRavipuram Junction, ErnakulamKochi 682 016Tel: 0484-4409420 / 4 / 5 / 7Fax: 0484-4409426e-mail: [email protected]

3-B, Shakespeare SaraniKolkata 700 071Tel: 033-44002572 / 3 / 4Fax: 033-22822589e-mail: [email protected]

A28, Indira Nagar, Faizabad Road Lucknow 226 016Tel: 0522-2312904 / 5 / 6Fax: 0522-2311671e-mail: [email protected]

No: 73, Karpaga Nagar,8th StreetK. PudurMadurai 625007Tel: 0452-2537404, 2521068Fax: 0452-2537552e-mail: [email protected]

EBG North Wing Office-Level 2 Gate 7, Powai CampusMumbai 400 072Tel: 022-67052874 / 2737 / 1156Fax: 022-67051112e-mail: [email protected]

#12, Shivaji NagarNorth Ambazari RoadNagpur 440 010Tel: 0712-2260012 / 3Fax: 0712-2260020 / 30e-mail: [email protected]

32, Shivaji Marg P. O. Box 6223New Delhi 110 015Tel: 011-41419514 / 5 / 6Fax: 011-41419600e-mail: [email protected]

L&T House P. O. Box 119191/1, Dhole Patil RoadPune 411 001Tel: 020-26135048Fax: 020-26124910, 26135048e-mail: [email protected]

3rd Floor Vishwakarma ChambersMajura Gate, Ring RoadSurat 395 002Tel: 0261-2473726Fax: 0261-2477078e-mail: [email protected]

Radhadaya ComplexOld Padra RoadNear Charotar SocietyVadodara 390 015Tel: 0265-6613610 / 1 / 2Fax: 0265-2336184e-mail: [email protected]

48-8-16, DwarakanagarVisakhapatnam 530 016Tel: 0891-6620411-2 / 3Fax: 0891-6620416e-mail: [email protected]

SP 50426 R3

Electrical Standard Products

Larsen & Toubro Limited

Powai Campus, Mumbai 400 072

Customer Interaction Center (CIC)

BSNL / MTNL (toll free) : 1800 233 5858

Reliance (toll free) : 1800 200 5858

Tel : 022 6774 5858

Fax : 022 6774 5859

E-mail : [email protected]

Website : www.LNTEBG.com

L&T AC DriveL1000A for Elevator Applications200 V Class 1.5 to 110 kW400 V Class 1.5 to 110 kW

Certified forISO9001 andISO14001

JQA-0422 JQA-EMO498

Larsen & Toubro infuses engineering with imagination. The Company offers a wide range of advanced solutions in the

field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology.

L&T Switchgear, a part of the Electrical & Automation business, is India's largest manufacturer of low voltage

switchgear, with the scale, sophistication and range to meet global benchmarks. With over five decades of experience

in this field, the Company today enjoys a leadership position in the Indian market with a growing international

presence.

It offers a complete range of products including powergear, controlgear, industrial automation, building electricals &

automation, reactive power management, energy meters, and protective relays. These products conform to Indian

and International Standards.

L&T introduces L1000A drive designed specifically for the elevator industry.

About us

Powai Switchgear Factory, Mumbai

L1000A drive

L&T L1000A drive is a reliable product with superior aesthetics, power & high performance vector control technology

that meets the current needs & future requirements.

•Easy setup and maintenance

– Terminal block with parameter backup

– DriveWizard Plus

•Safety

– Rescue operation

– Safe disable function

– Fault detection during run

– Preventive warnings

– High performance with low harmonic

distortion

•Setting the trend

– Runs induction and synchronous motors

– Compatible with a wide range of encoders

– Reduced operation time and more powerfulbraking

– Direct-to-floor

– Short floor

• Smooth, comfortable ride

– Smooth operation

– High starting torque without sensors

– Overshoot and anti-vibration control

– Variety of braking functions

– Anti-rollback

Features

1

Setting the Trend

u Cutting-edge drive technology to run a newly installed gearless synchronous motor, or a refurbished geared induction motor.

Minimizes equipment required for your application.

Capacity Range

200 V Class 1.5 to 110kW400 V Class 1.5 to 110kW

Control Mode

PM motors ・Closed Loop Vector Control for PM motors (SPM/IPM drive)

Induction motors ・V/f ControlOpen Loop Vector ControlClosed Loop Vector Control

・・

Runs Induction and Synchronous Motors

L1000A

Induction motorSynchronous SPM motor(base-mount)

Synchronous IPM motor(ultra-thin)

Use parameters to switch between motor types

Control Mode Starting TorqueSpeedRange

Motor Encoders and Option Cards

V/f Control 500% at 3Hz* N/A

Open Loop Vector Control

200% at 0.3 Hz* N/A

Closed Loop Vector Control

200% at0 r/min*1

1:40

1:200

1:1500Incremental Encoders:·PG-X3 (Line Driver)·PG-B3 (Complementary)

Closed Loop Vector Control for PM

200% at0 r/min*

1:1500

Incremental Encoders:·PG-X3 (Line Driver) ·PG-B3 (Complementary) Absolute Encoders: ·PG-F3(EnDat) ·PG-E3(ERN1387)

Loaded with Auto - Tuning Features

u

u

“Direct-to-Floor” functionImproves operational efficiency as well as ensures superior stopping precision.

Short Floor minimizes the creep speed time

Improved operation efficiency

to minimize operation time.

Reduced Operation Time and More Powerful Braking

u Faster Operation Time u Short Flooru Direct-to-Floor

Floor Contact (if avaiable)

Stop

Stopping distance correction at stop

contact (if available)

Stopping distance set in the drive

Stopping distanceset in the drive

Speedreference Stopping

distance

LevelingStopFloor

Contact(if available)

Stop

Stop

Actualstoppingdistance setin the drive

Stoppingdistancecalculated inthe drive fromride profilesettings

Stoppingdistance correction at stop contract(if available)

Leveling

* Drive and motor must be matched appropriately.

High-performance current vector control generates torque and precision control at low speeds.

powerful starting

Interface to match gear-less, SPM synchronous motors and every type of absolute encoder. High resolution and pole position detection for a smooth and safe ride.

u

u

Compatible with a Wide Range of Encoders

2

Applications requiring high starting torque, high speed, and high accuracy. Tuning is performed on the motor alone, decoupled from the load.

Applications where the motor must remain connected to the load during the auto-tuning process.

For re-tuning when the cable length between the motor/drive has changed or when motor/drive capacities are different.

Fine tunes the home pulse position when using an encoder with a synchronous motor. Possible with both Rotational andStationary Auto-Tuning.

RotationalAuto-Tuning

StationaryAuto-Tuning

Motor ResistanceAuto-Tuning

Encoder OffsetAuto-Tuning

Motor Tuning

u

Loaded with a variety of Auto-Tuning methods to ensure top performance.

Motor tuning features optimize drive settings disconnect the rope or car.

Tuning features for connected machinery.

without needing to

u

u

u

u

Smooth, Comfortable Ride

u

High Performance Starting Torque without Sensors

• Advanced Anti-Rollback

Kv (C5 parameter)

Torque reference

Processing

“Position hold”command input

NEW

Kp(S3-01)

Positioning Speed regulator

Speed feedbackS3-02

Position feedback

*Advanced Anti-Rollback: Torque compensation function that eliminates shock at start up by

preventing the car from moving when the brake is released.

u

Zero servo gain 2 (S3-02)(Before adjustment)

Torquereference

MotorspeedRollback

Torq

ue

7.5 8 8.5 9 9.5 10 10.5 11 11.5 12

Previous ModelL1000A

Zero servo gain 2 (S3-02)(After adjustment)

Torquereference

Motorspeed

Torq

ue

7.5 8 8.5 9 9.5 10 10.5 11 11.5

RollbackSuppressed

Previous ModelL1000A

3

Ensures smooth ride even without a load sensor, by providing high-performance torque compensation (Advanced Anti-Rollback*) and high resolution absolute encoder

Easy to adjust Anti-Rollback with sensors, preventing shock start and stop

Smooth Operation

Feed Forward achieves ideal speed response, eliminating vibration &

making it easy to tweak the speed control loop (ASR). (available soon)

Adjust jerk settings at the start and end of acceleration and deceleration to

create a perfectly smooth ride.

u

u

Built-in braking transistor up to 18.5 kW

0.4 18.5

Built-in braking transistor up to 30 kW

Previous Models

L1000A

Variety of Braking Functions

Overshoot and Anti - Vibration Control

Secondary current (torque) control

+++

Speed reference

Speed detection

• Feed Forward

FeedForwardControl Speed control

u All models up to 30 kW are equipped with a braking transistor for even more powerful braking options by just adding a braking resistor.

• Overshoot Compensation

1050

900

750

00 0.5 1

Previous Speed Control

Time (s)

w/Feed Forward Control

Spe

ed (

r/m

in)

Time (s)

Suppresses overshoot at the end of acceleration

050

900

750

00 0.5 1

30 kW

• Torque Ripple Comparison (Closed Loop Vector at zero speed)

Time (0.2 s/div)

【Previous model】

【L1000】

(%)

(2%/div)

Torq

ue

u

u

Has half the torque ripple compared to earlier models for an even

smoother ride

Provides precise motor torque performance capability for smoother

acceleration and deceleration

Safety, Easy Setup and Maintenance

Rescue Operation switches to backup battery or UPS in case of a power outage

• UPS Wiring and Operation • Backup Battery Wiring and Operation

*The illustrations above have been simplified, omitting switches and control signals that are otherwise required. Refer to the wiring diagrams included with the components in question.

UPS220 V, single phase

L1000A

24VDC

48-96VDC

24 V power supply unit

L1000A

Protects the elevator application with immediate fault detection.

u

u

Protection over - acceleration, speed reversal, wiring errors, and improper parameter settings.

Immediate response of hardware sensors if the motor encoder signal is lost, ensuring an even higher level of safety.

by detection of

Performance Life Monitors

u L1000A is equipped with performance life monitors that notify the user of part wear and maintenance periods to prevent problems before they occur.

Safe Disable Function

Preventive Warnings

Rescue Operation

Fault Detection During Run

• OveraccelerationFault Detection

*Actual operation varies by the control mode and motor encoder.

L4-13

Accel during normal operation

SpeedMotor speed during fault

Time

Speed

Time

SignalOveraccel

(fault signal)

Closed Open

Motor speed during normal operation

Fault acceleration detection level

Accel during faultAccel

Safety regulations

u Fully compliant with EN954-1 Cat. 3, ISO13849-1 (Cat. 3, PLd), and IEC/EN61058 SIL2, while eliminating the need for extra peripherals. Helps to easily satisfy EU standard for elevators EN81-1.

Operator Display Corresponding Component

LT-1 Cooling fan

LT-2 Capacitor

LT-3 Inrush prevention relay

LT-4 IGBTs

• Alarm Signals Output PLC or Control Device

Monitor status of input power supply

u Customized hardware immediately detects phase loss from the input power supply.

Detection remains active regardless of whether the drive is running or stopped.

An output signal can also be setup if a phase loss occurs.

u Both single-phase and 3-phase 220 V UPS and 48 -96 Vdc(400 V class) battery (24 V control power supply) can keep the elevator running in case of an emergency. Possible with all 200 V and 400 V class models

Automatically speed adjustment during voltage drop to prevent loss in motor speed.

Light Load Direction Search function triggered by UPS and battery voltage

Vdc(200 V class)

u

u

4

No longer needed!

・Space-saving・Highly reliable・Cost-efficient

Emergency stop

Power supply

Motor

Safe Disable wiring example (source mode)

Switch

AC drive

H2

H1

HC24 V

Main power

Power moduleN P

Control circuit

Gate block

Gate block

Jumper S3(set to SOURCE)

Standard Specifications

5

Model CIMR-LT2A 0018 0025 0033 0047 0060 0075 0085 0115 0145 0180 0215 0283 0346 0415

Max. Applicable Motor Capacity kW 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110

Rated Input Current A 18.9 28 37 52 68 80 82 111 136 164 200 271 324 394

Input Power kVA 9.5 14 18 27 36 44 37 51 62 75 91 124 148 180

Rated Output Current A 17.5 25 33 47 60 75 85 115 145 180 215 283 346 415

Rated Output Capacity kVA 6.7 9.5 12.6 17.9 23 29 32 44 55 69 82 108 132 158

Maximum Output Voltage Three-phase 200 to 240 Vac (proportional to input voltage)

Maximum Output Frequency 120 Hz (user adjustable)

Rated Voltage/ Rated Frequency Three-phase 200 to 240 Vac 50/60 Hz 270 to 340 Vdc

Carrier Frequency User adjustable between 2 and 15 kHz User adjustable between 2 and 10 kHz

Item Specifications

200

V Cl

ass

Model CIMR-LT4A 0009 0015 0018 0024 0031 0039 0045 0060 0075 0091 0112 0150 0180 0216Max. Applicable Motor CapacitykW 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110

Rated Input Current A 10.4 15 20 29 39 44 43 58 71 86 105 142 170 207

Input Power kVA 10.0 14.6 19.2 28.4 37.5 46.6 39.3 53.0 64.9 78.6 96.0 129.9 155 189

Rated Output Current A 9.2 14.8 18 24 31 39 45 60 75 91 112 150 180 216Rated Output Capacity kVA 7 11.3 13.7 18.3 24 30 34 48 57 69 85 114 137 165Carrier Frequency User adjustable from 2 to 15 kHz User adjustable from 2 to 10 kHz

Max. Output Voltage Three-phase 380 to 480 V (proportional to input voltage)

Max. Output Frequency 120 Hz (user adjustable)

Rated Voltage/Rated Frequency Three-phase 380 to 480 Vac 50/60 Hz 510 to 680 Vdc

Common Specifications

Allowable Voltage Fluctuation -15 to 10%

Allowable Frequency Fluctuation ±5%

Overload Tolerance 150% of rated output current for 60 s

+

400

V Cl

ass

Harmonics Suppression

Braking Function Braking Transistor Built-in Option Use drive parameters to select from the following control modes:

V/f Control, Open Loop Vector Control, Closed Loop Vector Control, Closed Loop Vector Control for PM

Frequency Control Range 0.01 to 120 HzFrequency Accuracy Digital reference: within ± 0.01% of the max. output frequency (-10 to +40˚C)(Temperature Fluctuation) Analog reference: within ± 0.1% of the max. output frequency (25˚C ± 10˚C)

Digital reference: 0.01 Hz, Analog reference: 0.03 Hz / 60 Hz (11 bit)Output Frequency Resolution 0.001 HzFrequency Setting Resolution -10 to 10 V, 0 to 10 V

150% / 3 Hz (V/f Control) 200%/ 0 r/min (Closed Loop Vector Control)

200% / 0.3 Hz (Open Loop Vector Control) 200% / 0 r/min (Closed Loop Vector Control for PM) 1:40 (V/f Control) 1:1500 (Closed Loop Vector Control)

1:200 (Open Loop Vector Control) 1:1500 (Closed Loop Vector Control for PM)Speed Control Accuracy ± 0.2% in Open Loop Vector Control (25˚C ± 10˚C), ± 0.02% in Closed Loop Vector Control (25˚C ± 10˚C)

10 Hz in Open Loop Vector Control (25˚C ± 10˚C), 50 Hz in Closed Loop Vector +Control (25˚C ± 10˚C)(excludes temperature fluctuation when performing Rotational Auto-Tuning)

Torque Limit All vector control modes allow separate settings in four quadrants with accuracy ± 5%Accel/Decel Time 0.00 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings)Braking Torque Approximately 125% when using a braking resistor optionV/f Characteristics User-selected programs and V/f preset patterns possible

Torque compensation at start, Auto-Tuning (for motor and encoder offset), braking sequence, Feed Forward,

Short Floor, Rescue Operation using back-up power supply, Light Load Direction Search,

Removable Terminal Block with Parameter BackupMotor Protection, Momentary Over current Protection, Overload Protection, Overvoltage Protection, Undervoltage

Protection, Heatsink Overheat Protection, Stall Prevention, Ground Fault Protection, Charge LEDArea of Use IndoorsAmbient Temperature - 10 to +50˚CHumidity 95% RH or less (no condensation)Storage Temperature -20 to +60˚C (short-term temperature during transportation)Altitude Up to 1000 meters

2 2Shock 10 Hz to 20 Hz, 9.8 m/s max. 20 Hz to 55 Hz, 5.9 m/s max. UL508C, EN61800-3, EN61800-5-1,EN954-1 Cat. 3, ISO13849-1 (Cat.3, PLd), IEC/EN61508 SIL2

Protective Design

Speed Response

IP20/NEMA Type 1 (CIMR-LT2A0018 to 2A0075 and 4A0009 to 4A0039), IP00 for further models

Direct-to-Floor,

Option Built-inDC Reactor

Control Method

Frequency Setting Resolution

Cont

rol C

hara

cter

istic

s

Starting Torque

Speed Control Range

Main Control Functions

Prot

ectio

n

Main Protection functions

Envi

ronm

ent

Standards Compliant

Peripherals Devices and Options

ERN1387:

Maximum input frequency: 20 kHz

Pulse monitor: Matches RS-422

Voltage output for encoder: 5 V, 200 mA max.

*Encoder cable: 10 m max.

Pulse monitor cable: 30 m max.

*Use a 17-pin encoder cable

For line drivers:

3 track (A, B, Z pulse)

Single track compatible (A pulse)

Maximum input frequency: 300 kHz

Pulse monitor: Matches RS-422

Voltage output for PG: 5 or 12V, max. 200mA

For complimentary and open collector types:

3 track (A, B, Z pulse)

Single track compatible (A pulse)

Maximum input frequency: 50 kHz

Pulse monitor output: Open collector

Voltage output for PG: 12V, max. 200mA

PG-E3Encoder Type (ERN1387)

EnDat2.1/01, EnDat2.2/01:

Maximum input frequency: 20 kHz

Pulse monitor: Matches RS-422

Voltage output for encoder: 5 V, 330 mA max or

8 V, 150 mA max.

Encoder cable: 20 m max.*

Pulse monitor cable: 30 m max.

*Use a 17-pin encoder cable

PG-F3Encoder Type (EnDat)

PG-X3Line Driver PG

PG-B3Complimentary Type PG

Connects the drive to a CANopen network.SI-S3CANopen

Device

PG

Spe

ed C

ontr

olle

r C

ard

Com

mun

icat

ions

Pulse generators

and encoders are

combined with a

feedback signal to

detect motor speed.

Allows the drive to

control the output

frequency to keep

motor speed constant.

PurposeModel

Back power supply for the control circuit and option boards for when the main

circuit loses power. Allows the user to refer to parameter settings and view drive

monitors during a power loss.

PS-A10LPS-A10H

24V Power Supply

Copy parameter settings in a single step, then transfer those settings to another drive.JVOP-181USB Copy Unit

Oth

er O

ptio

nsB

raki

ng

Braking Unit CDBR-4045CDBR-4030

CDBR-4220

Consume regenerative energy from motor in the braking resistor unit at deceleration and improve drive braking ability. *Note: Braking transistor is built-in upto 30 kW.

6

Simplify interfacing with the drive to perform tasks like- Read or modify, copy drive

parameters to another drive, operate the drive and monitor drive status.JVOP-180LCD Display

Braking Unit & Braking Resistor

7

Note: DBU shall be purchased from L&T, however DBR of given values must be purchased from local vendors.

L1000A Dynamic Braking Unit Dynamic Braking Resistor

Model

CIMR-LT4A CDBR- (W)

0009 390 150 1

0015 520 100 1

0018 780 75 1

0024 1040 50 1

0031 1560 40 1

0039 4800 32 1

0045 4800 27.2 1

0060 6000 20 1

0075 4045 1 9600 16 1

0091 4045 1 9600 13.6 1

0112 4030 2 6000 20 2

0150 4045 2 9600 13.6 2

0180 4045 2 9600 13.6 2

0216 4220 1 6000 20 3

Model Qty. Wattage Resistance Quantity

(Ω)

Built-in

200V

400V

L1000A Dynamic Braking Unit Dynamic Braking Resistor

Model

CIMR-LT2A CDBR-

0018 390 40 1

0025 520 30 1

0033 780 20 1

0047 2400 13.6 1

0060 1560 40 1

0075 3000 10 1

0085 3000 10 1

0115 4800 6.8 1

0145 2015 2 3000 10 2

0180 2022 2 4800 6.8 2

0215 2022 2 4800 6.8 2

0283 2110 1 4800 6.8 3

0346 2110 1 4800 6.8 4

0415 2110 1 4800 8 5

Model Qty. Wattage Resistance Quantity

(W) (Ω)

Built-in

Dimensions400 V

Cla

ss

Dimensions (mm)

IP00

WeightApplicable Motor (kW)

3

Fig

ure

9075

110

5545373022

CIMR-0180AAACIMR-0150AAA

CIMR-0216AAA

CIMR-0112AAACIMR-0091AAACIMR-0075AAACIMR-0060AAACIMR-0045AAA

ModelCIMR-LT4A

450325

500

325325325275250

W

705550

800

550510510450400

H

7942

96

4136362521

(kg)

330283

350

283258258258258

D

325260

370

260260260220195

W1

680535

773

535495495435385

H1

M10M6

M12

M6M6M6M6M6

d

Dimensions (mm)

NEMAType 1

WeightApplicable Motor (kW)

CIMR-0039FAACIMR-0031FAACIMR-0024FABCIMR-0018FABCIMR-0015FABCIMR-0009FAB

ModelCIMR-LT4A

2

1

Fig

ure

220180180140140140

W

350300300260260260

H

197187167167167164

D

192160160122122122

W1

335284284248248248

H1

M6M5M5M5M5M5

d

8.35.75.43.93.93.5

(kg)

18.515117.55.53.7

400 V

Cla

ss

20

0 V

Cla

ss

Dimensions (mm)

335335284248248248

H1

192192160122122122

W1

197197187167167164

D

365350300260260260

H

220220180140140140

W

2

1

Fig

ure

NEMA Type 1

CIMR-0075FAACIMR-0060FAACIMR-0047FABCIMR-0033FABCIMR-0025FABCIMR-0018FAB

ModelCIMR-LT2A

9.78.75.64.04.03.5

Weight

(kg)

M6M6M5M5M5M5

d

18.515117.55.53.7

Applicable Motor (kW)

20

0 V

Cla

ss Dimensions (mm) Weight

Applicable Motor (kW)

Fig

ure

45373022

CIMR-0180AAACIMR-0145AAACIMR-0115AAACIMR-0085AAA

ModelCIMR-LT4A

325325275250

W

550550450400

H

38372521

(kg)

283283258258

D

260260220195

W1

535535435385

H1

M6M6M6M6

d

IP003

8

Industrial Automation Product Range

Programmable Logic Controllers(PLCs)

AC Inverter Drives Softstarters

Servo Drives

Human Machine Interface

LnTOR - DC DrivesProgrammableSmart Relay - Lµ 1000

9

301111SP 50568

REGISTERED OFFICE AND HEAD OFFICEL&T House, Ballard EstateP. O. Box 278Mumbai 400 001Tel: 022-67525656Fax: 022-67525858Website: www.Larsentoubro.com

ELECTRICAL STANDARD PRODUCTS (ESP)501, Sakar Complex I Opp. Gandhigram Rly. Station Ashram RoadAhmedabad 380 009Tel: 079-66304006-11Fax: 079-66304025e-mail: [email protected]

38, Cubbon Road, P. O. Box 5098Bangalore 560 001Tel: 080-25020100/25020324Fax: 080-25580525e-mail: [email protected]

131/1, Zone IIMaharana Pratap NagarBhopal 462 011Tel: 0755-4098721/7/ 8 / 9Fax: 0755-2769264e-mail: [email protected]

Plot No. 559, Annapurna ComplexLewis RoadBhubaneswar 751 014Tel: 0674-6451342, 2436696Fax: 0674-2537309e-mail: [email protected]

SCO 32, Sector 26-D Madhya Marg, P. O. Box 14Chandigarh 160 026Tel: 0172-4646840, 4646853Fax: 0172-4646802e-mail: [email protected]

10, Club House Road, Annasalai Chennai 600 002Tel: 044-28462072 / 4 / 5 / 2109Fax: 044-28462102 / 3 e-mail: [email protected]

67, Appuswamy RoadPost Bag 7156 Opp. Nirmala CollegeCoimbatore 641 045Tel: 0422-2588120 / 1 / 5Fax: 0422-2588148e-mail: [email protected]

Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.

Electrical Standard Products (ESP) Branch Offices:

L&T House, Group MIG-5 PadmanabhpurDurg 491 001Tel: 0788-2213833 / 14 / 21 / 29Fax: 0788-2213820e-mail: [email protected]

Khairasol, Degaul AvenueDurgapur 713 212Tel: 2559848, 2559849, 2559844Fax: 0343-2553614e-mail: [email protected]

Milanpur Road, Bamuni MaidanGuwahati 781 021Tel: 0361-2550562 / 65Fax: 0361-2551308e-mail: [email protected]

II Floor, Vasantha Chambers5-10-173, Fateh Maidan RoadHyderabad 500004Tel: 040-66720250Fax: 040-23296468e-mail: [email protected]

D-24, Prithvi Raj Road, C-SchemeJaipur 302 001Tel: 0141-2385915 / 16 / 17 / 18Fax: 0141-2373280e-mail: [email protected]

Akashdeep Plaza, 2nd Floor P. O. GolmuriJamshedpur 831 003JharkhandTel: 0657-2312205 / 38Fax: 0657-2341250e-mail: [email protected]

Skybright Bldg; M. G. RoadRavipuram Junction, ErnakulamKochi 682 016Tel: 0484-4409420 / 4 / 5 / 7Fax: 0484-4409426e-mail: [email protected]

3-B, Shakespeare SaraniKolkata 700 071Tel: 033-44002572 / 3 / 4 Fax: 033-22821025/7587e-mail: [email protected]

A28, Indira Nagar, Faizabad Road Lucknow 226 016Tel: 0522-2312904 / 5 / 6Fax: 0522-2311671e-mail: [email protected]

No: 73, Karpaga Nagar, 8th StreetK. PudurMadurai 625007Tel: 0452-2537404, 2521068Fax: 0452-2537552e-mail: [email protected]

EBG North Wing Office-Level 2 Gate 7, Powai CampusMumbai 400 072Tel: 022-67052874 / 2737 / 1156Fax: 022-67051112e-mail: [email protected]

12, Shivaji NagarNorth Ambazari RoadNagpur 440 010Tel: 0712-2260012/3Fax: 0712-2260020/30e-mail: [email protected]

32, Shivaji Marg P. O. Box 6223New Delhi 110 015Tel: 011-41419514 / 5 / 6Fax: 011-41419600e-mail: [email protected]

L&T House P. O. Box 119 191/1, Dhole Patil RoadPune 411 001Tel: 020-26135048/26164048Fax: 020-26124910, 26135048e-mail: [email protected]

3rd Floor Vishwakarma ChambersMajura Gate, Ring RoadSurat 395 002Tel: 0261-2473726Fax: 0261-2477078e-mail: [email protected]

Radhadaya ComplexOld Padra RoadNear Charotar SocietyVadodara 390 015Tel: 0265-6613610 / 1 / 2Fax: 0265-2336184e-mail: [email protected]

48-8-16, DwarakanagarVisakhapatnam 530 016Tel: 0891-6620411-2 / 3Fax: 0891-6620416e-mail: [email protected]

Electrical Standard ProductsLarsen & Toubro LimitedPowai Campus, Mumbai 400 072Customer Interaction Center (CIC)BSNL / MTNL (toll free) : 1800 233 5858Reliance (toll free) : 1800 200 5858Tel : 022 6774 5858Fax : 022 6774 5859E-mail : [email protected] : www.LNTEBG.com