AC Fluke 437 II Power Quality Energy Analyzer Brochure 2

Embed Size (px)

Citation preview

  • 8/11/2019 AC Fluke 437 II Power Quality Energy Analyzer Brochure 2

    1/6

    With any other powerquality analyzer youre

    just wasting energy.

    Fluke 430 Series IIPower Quality andEnergy Analyzers

    actoolsupply.com

    actoolsupply.com

    actoolsupply.com

    Fluke 437-II 400 Hertz Power Quality Energy Analyzer

    http://www.aikencolon.com/fluke-437-ii-series-ii-power-quality-energy-analyzerhttp://www.aikencolon.com/Fluke-Test-Equipment_c_577.htmlhttp://www.aikencolon.com/http://www.aikencolon.com/fluke-437-ii-series-ii-power-quality-energy-analyzer
  • 8/11/2019 AC Fluke 437 II Power Quality Energy Analyzer Brochure 2

    2/6

    Fluke 430 Series II Models

    434 Series II Energy AnalyzerThe Fluke 434 Series II Energy Analyzer is the idealtool for energy logging. Utilizing the new EnergyLoss Calculator function, the 434 II measures thefiscal cost of energy wasted due to poor powerquality. This energy monetization capability identi-fies the most energy-wasteful areas of your facility,enabling you to identify energy saving solutions.Add basic power quality measurements to the pack-age and youve got yourself one powerful trouble-shooting tool.

    435 Series II Power Quality and Energy

    AnalyzerThink of the Fluke 435 Series II Power Qualityand Energy Analyzer as your insurance policy.No matter what goes wrong in your facility, with the435 II you will always be prepared. Equippedwith advanced power quality functions and energymonetization capabilities, there is no electrical issuethis model cant handle.

    PowerWave function captures fast RMS valuesand allows you to see every waveform todetermine how the voltage, current andfrequency values are interacting.

    Power Inverter Efficiency function measures both

    ac power and dc power, in and out, to monitorthe efficiency of your inverters.

    And, as with the other 430 Series II models, the435 II features an Energy Loss Calculator that willmonetize energy waste due to poor power quality,helping you save on the energy bill.

    437 Series II Power Quality and EnergyAnalyzerThe Fluke 437 Series II Power Quality and EnergyAnalyzer is designed specifically for the defenseand avionics industries. Equipped with all thefunctionalities of the 435 II including PowerWave,

    Power Inverter Efficiency and an Energy LossCalculator, the 437 II goes one step further bymeasuring up to 400 Hz. The ability to measureat a higher frequency is necessary for thoseworking in submarines, aircrafts, and other trans-port applications.

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke 437 II Power Quality Energy Analyzer Brochure 2

    3/6

    The new 430 Series II Three-Phase Power Quality

    and Energy Analyzers offer the best in power qual-ity analysis and introduce, for the first time ever,the ability to monetarily quantify energy losses.

    The new Fluke 434, 435 and 437 Series IImodels help locate, predict, prevent, and trouble-shoot power quality problems in three-phaseand single-phase power distribution systems.Additionally, these models feature revolutionarypower quality and energy measurement functionsthat help facilities reduce electrical power consump-tion, and improve the performance and lifespan ofelectro-mechanical equipment. Below you will findbrief descriptions of these new features.

    Unified power measurementPreviously, only experts could calculate how muchenergy was wasted due to power quality issues;utilities could calculate the cost, but the requiredmeasurement process was beyond the reach ofaverage electricians. With the new, patented UnifiedPower function of the 430 Series II, youcan use one handheld tool to determine how muchpower is being wasted, and calculate exactly whatthe extra consumption costs.

    Flukes patented Unified Power MeasurementSystem provides the most comprehensive view ofpower available, measuring:

    Parameters of Classical Power (Steinmetz 1897)and IEEE 1459-2000

    Detailed Loss Analysis

    Unbalance Analysis

    These UPM calculations are used to quantify thefiscal cost of energy loss caused by power qualityissues. The calculations are computed, along withother facility-specific information by an EnergyLoss Calculator that ultimately determines howmuch money a facility loses due to wasted energy.

    PowerWave data captureFor some users, loads switching is a cause of powerquality problems. When loads switch on, the

    current draw sometimes causes the voltage to drop

    to a level that causes other equipment to malfunc-tion. The PowerWave function available in the 435and 437 Series II models enables users to capturevoltage, current and frequency signals simultane-ously at a high speed to see which interaction ispotentially causing problems.

    PowerWave goes beyond standard power qual-ity measurements; PowerWaves fast data capturemode enables system dynamics to be characterized.Waveforms for voltage and current are continuouslycaptured for the specified time, and are displayedon screen in high detail; the power waveform isderived from the data. In addition, half-cycle RMSvalues for voltage, current, power and frequencycan be stored and retrieved for analysis. Thisfeature is particularly useful for testing of standbygeneration systems and UPS systems wherereliable switch-on can be vital.

    Power inverter efficiencyPower inverters take dc current and transform itinto ac current, or vice versa. Solar generationsystems usually include an inverter that takes thedc energy from the solar cells and converts it touseful ac power. Inverters can lose performanceover time and need to be checked. By comparingthe input power with the output power you can

    determine the system efficiency. All 430 Series IImodels can measure the efficiency of such invertersby simultaneously measuring the dc and ac powerof a system to determine how much power is lost inthe conversion process.

    400 HzBy increasing the power frequency to 400 Hz,transformers and motors can be much smaller andlighter than at 50 Hz or 60 Hz, which is an advan-tage in aircrafts, submarines, space crafts, and othermilitary equipment and hand-held tools. The437 II model captures power quality measurementsfor these types of avionic and military systems.

    Fluke 430 Series II Three-Phase PowerQuality and Energy Analyzers

    Energy Loss Calculator

    Useful kilowatts (power) available

    Reactive (unusable) power

    Kilowatts made unusable by unbalance issues

    Kilowatts made unusable by harmonics

    Neutral current

    Total cost of wasted kilowatt hours per year

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke 437 II Power Quality Energy Analyzer Brochure 2

    4/6

    Measures everything

    Measure true-rms, peak voltage and current,frequency, dips and swells, transients, interruptions,power and power consumption, peak demand,harmonics up to the 50th, inter-harmonics, flicker,mains signaling, inrush and unbalance.

    CAT IV 600 V and CAT III 1000 Vsafety ratingDesigned to help protect you and your equipment,the Fluke 430 Series II analyzers and accessoriesare all certified to meet the stringent standardsfor use in CAT IV 600 V and CAT III 1000 Venvironments such as power connections and

    outlets throughout a low-voltage power distributionsystem.

    Logger: record the detail you needUser-configurable, long-term recording of MIN, MAXand AVG readings for up to 150 parameters on allthree phases and nuetral. Enough memory is avail-able to record 600 parameters for over a year with10 second resolution, or capture smaller variationswith resolution down to 0.25 seconds. The loggerfunction is quickly accessed by the LOGGER button,the simple step-by-step setup makes capturing yourimportant measurements as easy as can be.

    Automatic transient displayWhen using the 435 and 437 II models, everytime an event or voltage distortion is detected, theinstrument triggers and automatically stores volt-age and current waveforms on all three phasesand neutral. The analyzer will also trigger when acertain current level is exceeded. Hundreds of dips,swells, interruptions and transients can be capturedthis way. You can see voltage transients as high as6 kV and as fast as 5 microseconds.

    System-monitor: summary screen of overallpower quality healthThe MONITOR mode delivers a dashboard display ofrms voltage, harmonics, flicker, interruptions, rapidvoltage changes, swells, unbalance, frequency andmains signaling.

    The dashboard is updated live, showing compli-ance of each parameter to EN50160 limits or yourown limits. Color-coded bars clearly show whichparameters are inside (pass) or outside (fail) limits.During a monitor session, you can easily drilldown to more detail of any parameter to view andcapture its trend for a report.

    Extensive data analysis possibilities

    The Fluke 430 Series II analyzers provide two waysto analyze measurements. Cursors and zoom toolscan be used for on-screen analysis of measurementdata. Additionally, the stored measurements canbe transferred to a PC with the included softwareto perform custom analysis and create reports.Measurement data can also be exported tocommon spreadsheet programs. Store hundreds ofmeasurement datasets and screen captures for usein reports (depending on memory capacity).

    Easy to usePre-programmed setups and user-friendly screens

    make power quality testing as simple as you wouldexpect from Fluke. The high-resolution color screenupdates every 200 ms and displays waveforms andwiring diagrams color coded to industry standards.Handy on-screen wiring diagrams for all commonlyused three-phase and single-phase configurationsguide you through connections.

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke 437 II Power Quality Energy Analyzer Brochure 2

    5/6

    View recordeddata in simplegraphs andtables.

    Easilycustomizethe report byselecting timeperiod andmeasurementsto include.

    Generate reports and view graphs with

    Fluke Power Log SoftwareDesigned to quickly view recorded data,the included Power Log software displaysall recorded parameters on interactive trends.Generate a professional report with theReport Writer function, or copy and pasteimages into the report document manually.

    Createprofessionalreports quicklyand easily.

    Fully Class-A compliantThe Fluke 435-II and 437-II are fully compliant

    with the new IEC 61000-4-30 Edition 2 Class-Astandard. With this powerful capability, all mea-surements will be consistent and reliable in accor-dance with the latest international standard. FlukesClass A compliance, including timesynchronization compliance has been indepen-dently verified, certification is available on request.

    IEC 61000-4-30 Edition 2 Class Compliance

    437-II 435-II 434-II

    Measurement algorithms

    Voltage accuracy 0.1 % of

    Vnom

    0.1 % of

    Vnom

    0.5 % of

    VnomClass compliance A A S

    Time synchronization Optional with GPS430 accessory

    What is Class-A conformity?

    Power quality measurement is a relatively new,and quickly evolving field. There are hundreds ofmanufacturers around the world with unique mea-surement methodologies. Whereas basic single-and three-phase electrical measurements like rmsvoltage and current were defined long ago, manypower quality parameters were not previously

    defined, forcing manufacturers to develop their ownalgorithms. With so much variation between instru-ments, electricians tend to waste too much time try-ing to understand an instruments capabilities andmeasurement algorithms instead of understandingthe quality of the power itself!

    The new IEC 61000-4-30 Edition 2 Class-Astandard takes the guesswork out of selectinga power quality instrument. The standard IEC61000-4-30 Edition 2 defines the measurementmethods for each parameter to obtain reliable,repeatable and comparable results. In addition,the accuracy, bandwidth and minimum set ofparameters are all clearly defined. The 435 and

    437 Series II models include flagging and availableinternal clock time-synching to fully comply withthe rigorous requirements of Class A compliance.

    The Edition 2 standard includes a new classof instrument, Class S. While not as accurate asClass A instruments, Class S instruments such asthe 434 Series II Energy Analyzer produce resultsthat are consistent with Class A instruments.

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke 437 II Power Quality Energy Analyzer Brochure 2

    6/6

    Model Fluke 434-II Fluke 435-II Fluke 437-II

    IEC 61000-4-30 compliance Class S Class A Class A

    Volt Amp Hz

    Dips and swells

    Harmonics

    Power and energy

    Energy loss calculator

    Unbalance

    Monitor

    Inrush

    Event waveform capture

    Flicker

    Transients

    Mains signaling

    Power wave

    Power inverter efficiency

    400 Hz

    C1740 Soft Case

    C437-II Hard Case with rollers

    SD card (Max 32 GB) 8 GB 8 GB 8 GB

    All models include the following accessories TL430 test lead set, 4 x i430 thin flexi current probes, BP290 battery, BC430 power adapterwith international power adapter set, USB cable A-B mini and PowerLog CD.

    430 Series II Power Quality and Energy

    Analyzer selection chart

    actoolsupply.com