About Water Purification Station Changgen Yang. Main water purification station. It is too high in this plot, we would like to change to ~4m. It is located

Embed Size (px)

Citation preview

About Water Purification Station

Changgen Yang

Main water purification station. It is too high in this plot, we would like to change to ~4m. It is located 50m south of the intersection point of the construction tunnel with main tunnel

13m

11m

A

B

C

Pump for water transfer

Pump for water circulation Pump for waste water

Seepage water

Water pre-treatment

Pure Water System

City water

Pool 0#

Pool 3#

Pool 1# Pool 2#

Drain stainless pipeline for water pool filling

pressure pump

circulation pump

waste water pump

pressure pump

circulation pump

waste water pump DN65 flux 1.7 kmAttenuation:0.4MPa

DN65 flux 1.7 kmAttenuation:0.4MPa

pressurepumpsink

Waste water pool, pump inside

Pool #0

Pool #0

drypumproom

pressurepump

waste water pool

waste water pump

waste water level

Further calculation needed to see if we can share thepump in the circulationSystem - it may waster energy to do so since the lift path needn’t be large.l

city water pool

waste water

waste water pump room

pressure pump room

pure water pipeline system - s. steel

exchange water pipeline - plastic or s. steel

pre-treatment water pipeline - plastic or Carbon steel. Use canal above.

waste water pipeline - plastic or Carbon steell

A One may use the same pump for water circulation and water transfe

r between pool 1~3 and pool 0, but these pumps may different for different purpose.

B It is possible to use the tunnel seepage water if we add a pre-treatm

ent at least to filter the seepage water, the estimated cost is about 30k$.

C One can put all the pumps in the sump, the sump exit can be in the

EH (crane access easier but ditch will be needed from water circulation room to the sump ), or in the water circulation room (no crane and no ditch). Put the water circulation pump in the water pool may not good because it’s operation might cause noise to the PMTs.

A B

A B

Move the pump pit to the other corner of the pool or directly to the water purification room? (need a crane to lower pump)

water well

drain strobe

RPC rail

RPC rail travel limit

scale

Unit for pipe diameter is mm, others m

concrete

spray-concrete

armor plate

brick wall

crane hook limit

fire doors

#3 laboratory diagram (detectors 2x2)

Low noise lab Shelter room

toilet

Main tunnel

Gas room

Electro-nics room

Water purification room

Emergency exit

fire door

Control cabinet