2
Diatron MI PLC Papírgyár u. 58-59. H-1038 Budapest, HUNGARY Phone: (36-1) 436 9800 Fax: (36-1) 436 9809 www.diatron.com Abacus Junior VET and Abacus Junior VET 5 Diatron reserves the right to change any of the specificaons without prior noce. *Usage of original Diatron reagents is recommended. Full specificaons are available on request or can be obtained from www.diatron.com (select ”products”.) Parameters Measuring principle Throughput Sample volume Sampling method Sample profiles Reagents* Calibraon Quality control User interface User language Soware upgrade Data storage capacity Printout External keyboard Interfacing capabilies Operang mode Size (WxDxH) Weight Operang environment Abacus Junior VET Abacus Junior VET 5 18 parameters, including 3-part WBC differenal: WBC, LYM, MID, GRA, LYM%, MID%, GRA%, RBC, HCT, MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW Impedance method 22-28 tests/hour 25 μl of whole blood Open tube system with automac sample rotor Dog, Cat, Horse, Cale, Pig, Mouse, Rat, Rabbit, Ferret, Chimp, Sheep, Goat and user defined profiles Isotonic Diluent, Lyse, Cleaner and Rinse Automac or manual 6 lots Easy-to-use, menu driven user interface with 6 soware buons (with icons), 6 hardware funcon buons, cursor and numeric keys Mullingual user interface USB 1000 (2000/10000 oponal) result, including histograms Built-in printer: Seiko “Easy Paper Operaon” thermal printel, 56 mm wide roll paper (oponal) PS/2, USB Serial port, USB Mul user mode 320 × 260 × 365 mm 12 kg Temperature: 15-35°C Relave humidity: max 80% (non-condensing) 22 parameters, including 5-part WBC differenal: WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW Impedance method 22-28 tests/hour in 3-part mode 15-20 test/hour in 5-part mode 25/50 μl of whole blood in 3/5-part mode Open tube system with automac sample rotor – in 5-part mode: Dog, Cat, Horse, Control blood – in 3-part mode: Dog, Cat, Horse, Cale, Pig, Mouse, Rat, Rabbit, Ferret, Chimp, Sheep, Goat, Guinea-pig and user defined profiles Isotonic Diluent, Lyse, Diff VET5, Cleaner and Rinse Automac or manual 6 lots Easy-to-use, menu driven user interface with 6 soware buons (with icons), 6 hardware funcon buons, cursor and numeric keys Mullingual user interface USB 1000 (2000/10000 oponal) result, including histograms Built-in printer: Seiko “Easy Paper Operaon” thermal printel, 56 mm wide roll paper (oponal) PS/2, USB Serial port, USB Mul user mode 320 × 260 × 365 mm 13 kg Temperature: 15-35°C Relave humidity: max 80% (non-condensing) Abacus Junior VET and Abacus Junior VET 5 Innovave Soluons in Hematology Your distributor: Technical Specificaons Abacus Junior VET and Abacus Junior VET 5 and Abacus Junior VET 5 Type Name Code Pack Size Isotonic Diluent DiatroDil VET D1022 20 L Hemolysing Agent DiatroLyse VET D2041 1 L Hemolysing Agent Diatro Diff VET5 D2051 1 L Cleaner Diatro Cleaner D5011 1 L Cleaner Diatro Cleaner D5015 5 L Rinse soluon Diatro Rinse VET D4011 1 L Rinse soluon Diatro Rinse VET D4015 5 L Reagent Pack Junior VET Reagent Pack DRP01 set Reagent Pack Junior VET 5 Reagent Pack DRP02 set We offer hematology systems of two interlocking components: analyzers and reagents. Diatron hematology analyzers show the best perfomance with the original reagents developed and made by Diatron. All our reagents are cyanide-free and have extended shelf life. Reagents

abacus juniorVET VET5 - protectlife-intl. · PDF fileAbacus Junior VET and Abacus Junior VET 5 Ease of use • The user-friendly interface enables fast and effi cient work • The

  • Upload
    vankien

  • View
    233

  • Download
    3

Embed Size (px)

Citation preview

Page 1: abacus juniorVET VET5 - protectlife-intl. · PDF fileAbacus Junior VET and Abacus Junior VET 5 Ease of use • The user-friendly interface enables fast and effi cient work • The

Diatron MI PLCPapírgyár u. 58-59.

H-1038 Budapest, HUNGARYPhone: (36-1) 436 9800

Fax: (36-1) 436 9809www.diatron.com

Abacus Junior VET and Abacus Junior VET 5

Diatron reserves the right to change any of the specifi ca� ons without prior no� ce.

*Usage of original Diatron reagents is recommended. Full specifi ca� ons are available on request or can be obtained from www.diatron.com (select ”products”.)

Parameters

Measuring principleThroughput

Sample volumeSampling methodSample profi les

Reagents*Calibra� onQuality controlUser interface

User languageSo� ware upgradeData storage capacityPrintout

External keyboardInterfacing capabili� esOpera� ng modeSize (WxDxH)WeightOpera� ng environment

Abacus Junior VET Abacus Junior VET 518 parameters, including 3-part WBC diff eren� al:WBC, LYM, MID, GRA, LYM%, MID%, GRA%, RBC, HCT, MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW

Impedance method22-28 tests/hour

25 μl of whole bloodOpen tube system with automa� c sample rotorDog, Cat, Horse, Ca� le, Pig, Mouse, Rat, Rabbit, Ferret, Chimp, Sheep, Goat and user defi ned profi les

Isotonic Diluent, Lyse, Cleaner and RinseAutoma� c or manual6 lotsEasy-to-use, menu driven user interface with 6 so� ware bu� ons (with icons), 6 hardware func� on bu� ons, cursor and numeric keysMul� lingual user interfaceUSB1000 (2000/10000 op� onal) result, including histogramsBuilt-in printer: Seiko “Easy Paper Opera� on” thermal printel, 56 mm wide roll paper (op� onal)PS/2, USBSerial port, USBMul� user mode320 × 260 × 365 mm12 kgTemperature: 15-35°CRela� ve humidity: max 80% (non-condensing)

22 parameters, including 5-part WBC diff eren� al: WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDWImpedance method22-28 tests/hour in 3-part mode15-20 test/hour in 5-part mode25/50 μl of whole blood in 3/5-part modeOpen tube system with automa� c sample rotor– in 5-part mode: Dog, Cat, Horse, Control blood– in 3-part mode: Dog, Cat, Horse, Ca� le, Pig, Mouse, Rat, Rabbit, Ferret, Chimp, Sheep, Goat, Guinea-pigand user defi ned profi lesIsotonic Diluent, Lyse, Diff VET5, Cleaner and RinseAutoma� c or manual6 lotsEasy-to-use, menu driven user interface with 6 so� ware bu� ons (with icons), 6 hardware func� on bu� ons, cursor and numeric keysMul� lingual user interfaceUSB1000 (2000/10000 op� onal) result, including histogramsBuilt-in printer: Seiko “Easy Paper Opera� on” thermal printel, 56 mm wide roll paper (op� onal)PS/2, USBSerial port, USBMul� user mode320 × 260 × 365 mm13 kgTemperature: 15-35°CRela� ve humidity: max 80% (non-condensing)

Abacus Junior VET and Abacus Junior VET 5

Innova� ve Solu� ons in Hematology Your distributor:

Technical Specifi ca� ons

Abac

us Ju

nior

VET

an

d Ab

acus

Juni

or V

ET 5

and

Abac

us Ju

nior

VET

5

Type Name Code Pack SizeIsotonic Diluent DiatroDil VET D1022 20 LHemolysing Agent DiatroLyse VET D2041 1 LHemolysing Agent Diatro Diff VET5 D2051 1 LCleaner Diatro Cleaner D5011 1 LCleaner Diatro Cleaner D5015 5 LRinse solu� on Diatro Rinse VET D4011 1 LRinse solu� on Diatro Rinse VET D4015 5 LReagent Pack Junior VET Reagent Pack DRP01 setReagent Pack Junior VET 5 Reagent Pack DRP02 set

We off er hematology systems of two interlocking components: analyzers and reagents. Diatron hematology analyzers show the best perfomance with the original reagents developed and made by Diatron. All our reagents are cyanide-free and have extended shelf life.

Reagents

Page 2: abacus juniorVET VET5 - protectlife-intl. · PDF fileAbacus Junior VET and Abacus Junior VET 5 Ease of use • The user-friendly interface enables fast and effi cient work • The

Abacus Junior VET and Abacus Junior VET 5

Ease of use

• The user-friendly interface enables fast and effi cient work• The large back-lit LCD allows accurate pa� ent data entry

and monitoring of results and histograms• 6 level QC, L-J graphs and self diagnos� c func� ons let you monitor

reliability and accuracy • The instrument features a logically constructed mul� lingual

opera� ng menu• New features can be easily introduced by simple so� ware upgrades• Pa� ent data can easily be saved in the database or using a pen-

or disk drive• Both models can interface to your laboratory computer for further

processing of the measured data. Results can also be retrieved on the built-in roll paper printer or on an external printer

Abacus Junior vet and Abacus Junior vet

High performance

• Complete Hematology profi les for a wide range of species

• Abacus junior VET provides 18-parameter, while Abacus junior VET 5 a 22-parameter hematology results.

• Abacus junior VET off ers pre-defi ned 3-part diff . profi les for dog, cat, horse, ca� le, pig, mouse, rat, rabbit, ferret, chimp, sheep and goat. In addi� on, Abacus junior VET 5 off ers 5 part diff . results for dog, cat, horse and ca� le. Both instruments allow user defi ned profi les in 3-part mode.

Reliable and effi cient

• Abacus Junior VET and Abacus Junior VET 5 are almost maintenance free resul� ng in minimal disrup� on of opera� on

• Diatron Vet analyzers are small and light. Their compact size makes the instruments ideal for use in veterinary prac� ces requiring minimum desktop space

• Precise and reliable 3-part and 5-part veterinary hematology profi les are guaranteed even in the most demanding clinical environment by u� lizing industry standard electronic and mechanic components

5Abacus Junior VET and Abacus JuniorVET 5 off er an op� mal solu� onfor veterinary clinics and prac� ces,which require high quality 3-partor 5-part WBC diff eren� al results.