8
A World of Solutions in Fire Protection Systems

A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

Embed Size (px)

Citation preview

Page 1: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

A World of Solutions inFire Protection Systems

Page 2: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

FireWarden-50C

• Single Data Communications Loop DCLA, DCLB, DCLC• Supports 198 addressable points (99 detectors/99 modules)• 80-character LCD Backlit Display (4 lines x 20 characters)• Four NACs with built-in synchronization • Built-in Digital Alarm Communicator Transmitter (DACT)• Fully programmable from local keypad, local PS-2 keyboard or PC

via VFWarden Windows® Programming Utility• Enhanced drift compensation, maintenance alert and auto detector

test features• EIA-485/ANN-BUS interface supports up to 32 ACS Series annunciators

or up to eight ANN-BUS devices• Multi-module series: NC-100-6A, NMM-100-10A, NC-100R-6A,

NZM-100-6A

Peripheral Devices

Addressable Devices

To Central Station

FDU-80C ACS Annunciator

PRN-6 Printer

NOT-BG12LXAddressable

Manual Pull Station

NH-100AThermal Detector

NP-100APhoto Detector

i3 Photo Detector

EIA-232

ANN-BUS or ACS EIA-485 (one or the other)

24 VDC

DCL Loop

NC-100AControl Module

NI-100AIon Detector

FireWarden-100CFire Alarm Control Panel

FireWarden-100C

NZM-100A2-Wire DetectorMonitor Module

1451AIon Detector

NDM-100ADual Monitor Module

• Single Data Communications Loop DCLA, DCLB, DCLC• Loop has 50 addressable device capacity in any combination

of addressable detectors and modules• Two independently programmable Class A or Class B Notification

Appliance Circuits (NACs)• Enhanced drift compensation, maintenance alert and auto detector

test features• New annunciator protocol with connections for up to eight remote

devices, including 80-character LCD annunciators, remote printers,relays and graphic annunciators

• Built-in Digital Alarm Communicator Transmitter (DACT) with remoteupload/download programming and diagnostic capability (requiresVFWarden-CD)

• Multi-module series: NC-100-6A, NMM-100-10A, NC-100R-6A, NZM-100-6A

Peripheral Devices

Addressable Devices

To Central StationOver Telephone

Network

PRN-6 Printer

NOT-BG12LXAddressable

Manual Pull Station

NH-100A SeriesThermal Detector

NP-100APhoto Detector

i3 Photo Detector

EIA-232

ANN BUS

24 VDC

DCL Loop

NC-100AControl Module

NI-100AIon Detector

NMM-100A/NMM-100PA

FireWarden-50CFire Alarm Control Panel

NZM-100A2-Wire DetectorMonitor Module

1451AIon Detector

DNRA Duct Detector

NDM-100ADual Monitor Module

Multi-module Series

NMM-100A/NMM-100PA

ANN-80C N-ANN-LED

Terminal Mode EIA-485

DNRA Duct Detector

Multi-module Series

Page 3: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

NSP-25C Panel

Conventional Panels

Peripheral Devices

Addressable Devices

To Central StationOver Telephone

Network

NOT-BG12LXAddressable

Manual Pull Station

HFS-TA Thermal Detector

HFS-PA Photo DetectorDCL Loop

HFS-MRARelay Module

HFS-PTAPhoto/Thermal Detector

HFS-MMAMonitor Module

HFS-DADuct Detector

• Twenty-five DCL points• Two amp power supply• Two class B NACs• Spartan HFS family of devices• Five zones• Built-in dialer• LEDs for system status; alarm, trouble, supervisory, etc. • Uses Windows Internet Explorer® for programming via laptop Ethernet port• UL/ULC/ETL listed

NSP-25CFire Alarm Control Panel

SFP-5UDC 5-Zone Control Communicatorand SFP-10UDC 10-Zone Control Communicator• SFP-5UDC has 5 Programmable Class B Initiating

Device Circuits (IDCs)• SFP-10UDC has 10 programmable Class B Initiating

Device Circuits (IDCs)• 4 Class B Notification Appliance Circuits (NACs)• Optional CAC-5X Class A converter module for NAC’s

and IDCs (2 required)• 7 amps of NAC power• Programmable NACs • Built-in strobe synchronization• Built-in Digital Alarm Communicator/Transmitter,

LCD display and keypad• Built-in programmer• 24VDC • FM approved

RP-2001C Supression Control Panel Deluge-Preaction • Designed for sprinkler standards NFPA 13, 15 and 16• Dual hazard operation• Adjustable waterflow discharge timer and two soak timers• Cross-zone (double-interlock) capability• Six programmable Class B Initiating Device Circuits (IDCs)• Four programmable Class B output circuits

- (special application power)• Built in Strobe synchronization• 7.0 amps total 24 VDC output current• 80-character LCD display (backlit)• Disable/Enable control per input zone and output zone• Built-in Programmer• FM approved

RP-2002C Supression Control Panel Agent Release • Designed for agent releasing standards

NFPA 12, 12A, 12B, and 2001• Disable/Enable control per input zone and output zone• Dual hazard operation• Adjustable pre-discharge, discharge and waterflow

delay timers• Cross-zone (double-interlock) capability• Six programmable Class B Initiating Device Circuits (IDCs)• Four programmable Class B output circuits - (special application power)• Built in Strobe synchronization• 7.0 amps total 24 VDC output current• Built-in Programmer• 80-character LCD display (backlit)• FM approved

RP-2001C

CFP-2410B 10-Zone Control• 10 Initiating Device Circuits (IDC)

- All zones accept two-wire smoke detectors and any normally-open contact devices

- Zones 1 - 8 configured as general alarm zones- Zones 9 and 10 programmable as smoke zones

or supervisory alarm zones• 2 built-in, programmable NACs• 2.5 amps of NAC power, expandable to 5.0 amps• 3.6 amps of total system power expandable to 6.6 amps• Alarm, Trouble and Supervisory, Form-C relays standard

CFP-2401B 1-Zone Control and CFP-2402B 2-Zone Control• CFP-2401B has 1 Class B Initiating Device Circuit (IDCs)• CFP-2402B has 2 Class B Initiating Device Circuits (IDCs)• 1 Class B built-in NAC• IDCs support normally-open contact

devices and two-wire detector• 1.25 amps of NAC power• NAC features 60-second Silence Inhibit, standard• Alarm and Trouble, Form-C relays standard• Fuseless, power-limited technology meets

all the latest ULC power-limiting requirements

RP-2002C

SFP-5UDC

SFP-10UDC

CFP-2401B

CFP-2402B

CFP-2410B

Page 4: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

ONYX® Series NFS-320C

ONYX NFS-320CIntelligent Single Loop Fire Alarm Control Panel• One Data Communications Line (DCLA, DCLB, DCLC) with 318 devices• Point Capacity: Up to 159 detectors (any mix of ion, photo, laser photo, thermal,

or multisensor) and 159 modules (N.O. manual stations, two-wire smoke, notification, or relay)

• 6.0 Amp power supply with four Class A/B built-in Notification Appliance Circuits (NACs)• Fully field programmable with 80-character display (includes QWERTY keypad)

or offline with VeriFireTM Tools Windows-based program utility• USB Support for VeriFire Tools• Removable chassis design for easy installation and service• EIA-485 interface supports up to 32 annunciators • ONYX Intelligent Sensing advanced set of software algorithms delivers rapid, intelligent

response to incipient fire signatures, while substantially reducing nuisance alarms• Networkable with NOTI•FIRE•NET (NFN), High Speed NOTI•FIRE•NET, and ONYXWorks®

up to 200 nodes per NFN• Listed for releasing• FM approved• Available in French

PRN-6 Printer

FSP-851APhoto Detector

FAPT-851AAcclimate Plus

Detector

EIA-485FSI-851A

Ion Detector

RSGManual Pull

Station

DNRA Duct Detector

FMM-1AMonitor Module

P2RAHorn/Strobe

FZM-1A2-Wire Detector Monitor Module

Intelligent Devices Peripheral Devices

LCD2-80

FST-851AThermal Detector

FSC-851AIntelliQuadTM Multi-

criteria Detector

FSL-751AVIEWTM Detector

ACM-24AT

ACPS-610Addressable Charger

Power Supply

Gas Detector

FMM-1A CO1224A

P2RAHorn/Strobe

P2RAHorn/Strobe

i3 Photo Detector

PF24VAExitPointTM

1451AIon Detector

EIA-232

Built for Speed

EIA-485 (Terminal)

XP Series Multi-module

Page 5: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

ONYX® Series NFS2-640ONYX NFS2-640Intelligent 1 to 2 Loop Fire Alarm Control Panel• One Data Communications Line (DCLA, DCLB, DCLC), expandable to two• Point Capacity: Up to 159 detectors (any mix of ion, photo, laser photo, thermal, or multisensor) and 159 modules

(N.O. manual stations, two-wire smoke, notification, or relay) per DCL• 318 devices per DCL, 636 devices per panel• 80-character, 640-character, or displayless options• ONYX Intelligent Sensing - nine levels of sensitivity, drift compensation and maintenance alert, and auto detector test• 6.0 Amp power supply with four Class A/B built-in Notification Appliance Circuits (NACs)• Fully field programmable with 80-character display (includes QWERTY keypad) or offline

with VeriFireTM Tools Windows- based program utility• Optional Integrated Digital Voice Command with eight channels of high quality digital audio on a single cable• Unique environment detection includes VIEW® for clean environments, IntelliQuadTM for detection of

all four fire signatures, and Acclimate PlusTM multi sensor that adjusts sensitivity automatically • Networkable with NOTI•FIRE•NET (NFN), High Speed NOTI•FIRE•NET, and ONYXWorks up to 200 nodes for NFN• Listed for releasing• FM approved• Available in French

FSP-851APhoto Detector

FAPT-851AAcclimate Plus

Detector

FSI-851AIon Detector

RSGManual Pull

Station

DNRA Duct Detector

FMM-1AMonitor Module

P2RAHorn/Strobe

FZM-1A2-Wire Detector Monitor Module

Intelligent Devices Peripheral Devices

FST-851AThermal Detector

FSL-751AVIEW Detector

ACPS-610Addressable Charger

Power Supply

Gas Detector

FMM-1A CO1224A

P2RAHorn/Strobe

P2RAHorn/Strobe

i3 Photo Detector

PF24VAExitPoint

1451AIon Detector

Unparalleled Agility

PRN-6 Printer

Digital or Analog Audio Loop*

EIA-232

Speaker Circuit

Digital Audio Amplifier*

Firefighter Telephone Circuit

IntegratedDigital Voice

Evacuation*640 must have an NCA-2 (not shown)

to support Digital Voice Evacuation

FSC-851AIntelliQuad Multi-criteria Detector

EIA-485

FDU-80C

ACM-24ATEIA-485

XP Series Multi-module

Page 6: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

ONYX® Series NFS2-3030ONYX NFS2-3030 - Intelligent 1 to 10 Loop Fire Alarm Control Panel• Up to 10 Data Communications Lines (DCLA, DCLB, DCLC)• Point Capacity: Up to 159 detectors (any mix of ion, photo, laser photo, thermal, or multisensor)

and 159 modules (N.O. manual stations, two-wire smoke, notification, or relay) per DCL• Large 640-character LCD backlit display (16 lines x 40 characters) or displayless (a node on a network)• Networkable with NOTI•FIRE•NET (NFN), High Speed NOTI•FIRE•NET, and ONYXWorks compatible

up to 200 nodes for NFN• Application code is saved in Flash memory• Built-in Degraded Mode option. In the event of a CPU failure, the loop control modules will continue

to monitor fire alarm conditions• ONYX Intelligent Sensing advanced set of software algorithms delivers rapid, intelligent response

to incipient fire signatures, while substantially reducing nuisance alarms including nine levelsof alarm and pre-alarm, cooperative sensing and self-optimizing pre-alarm

• Optional integrated Digital Voice Command with eight channels of high quality digital audio and fivechannels of fire fighter’s telephone, all on a single riser

• EIA-485 annunciators, including custom graphics• FM6320 approved gas detection system• Listed for releasing• FM approved• Available in French

PRN-6 Printer

FSP-851APhoto Detector

FAPT-851AAcclimate Plus

Detector

FSI-851AIon Detector

RSGManual Pull

Station

DNRA Duct Detector

FMM-1AMonitor Module

P2RAHorn/Strobe

FZM-1A2-Wire Detector Monitor

Module

Intelligent Devices Peripheral Devices

FST-851AThermal Detector

FSL-751AVIEW Detector

ACPS-610Addressable Charger

Power Supply

FMM-1A CO1224A

P2RAHorn/Strobe

P2RAHorn/Strobe

i3 Photo Detector

PF24VAExitPoint

1451AIon Detector

EIA-232

SCS Smoke Control Station Custom GraphicsAnnunciator

ACM-24AT

EIA-485

EIA-485

Digital or Analog Audio Loop

Audio

Rise

rsPh

one

Rise

rsTo

XPI

Q Tr

ansp

onde

r

Speaker Circuit

Digital Audio Amplifier

Firefighter Telephone Circuit

Speaker Circuit

Digital Audio Amplifier

Firefighter Telephone Circuit

Sheer Power and Performance

IntegratedDigital Voice

Evacuation

FMM-4-20A Gas Detector

FSC-851AIntelliQuad Multi-criteria Detector

LCD-160 DisplayLCD2-80*

* RDP port can support LCD-160 or LCD2-80 inTerminal Mode, but not both at the same time

XP Series Multi-module

Page 7: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

Networking and Integration

Unified Commandand Control

Eche

lon

NOTIFIER Fire Panels Competitive Fire Interface

Ademco Vista SecurityCCTV IntegrationNetwork Printer

IP

DACR

NOTIFIER Fire Panels FirstVisionTM

DACR

Fire and Security Panels with DACT

ONYXWorks Workstation

FirstVisionTM

NCA-2

NWS

NOTIFIER Fire Panels

Additional Network Literature• Network & Integrated Product Brochure• ONYXWorks Integrated Facilities Monitoring System Brochure

Telco Lines

NOTI•FIRE•NETTM Features• Supports ONYX Series (NFS-320C, NFS-640, NFS2-640, NFS-3030, NFS2-3030)

and Digital Voice Command• Backward compatible to NOTIFIER classic series of Fire Alarm Control Panels

(AFP-200, AFP-400, AFP-1010 and AM2020)• Network Control Annunciator (NCA) is used to annunciate network events,

and provide network control• BACnet Gateway supports industry standard BACnet/IP connectivity

to Building Automation Systems (BAS/BMS)• NOTI•FIRE•NET Web Server (NWS) provides remote read status

capabilities and instant email and text messaging • ONYX FirstVision intuitive touch screen display for first responders• Wire and Multi-Mode Fiber options

High Speed NOTI•FIRE•NETTM Features• Supports ONYX Series (NFS-320C, NFS-640, NFS2-640, NFS-3030, NFS2-3030),

NCA-2 and Digital Voice Command• Supports BACnet Gateway, NWS and FirstVision Applications• Increased network protocol communications; 12Mb VDSL for Wire and 100Mb

for Multi-Mode Fiber and Single-Mode Fiber• Increased node count to 200 nodes including digital audio applications

ONYXWorks® Features• Supports a client-server technology based on Echelon and a NOTI•FIRE•NET

peer-to-peer network• Integrates competitive Fire Alarm Control Panel interfaces, security panels

and CCTV applications• Connects new and existing equipment into a Local Area Network (LAN)

or Wide Area Network (WAN)• Supports Digital Alarm Communicator Receiver (DACR) interface

for monitoring of remote panels• Graphic Editing mode allows for on-

site programming of floor plan screens, devices and navigational buttons

• Windows XP Support

Page 8: A World of Solutions in Fire Protection · PDF fileFire Protection Systems. ... Trouble and Supervisory, Form-C relays standard ... channels of fire fighter’s telephone, all on a

M-B-PI2-CAN 3/11

For over 60 years, NOTIFIER has been a leader in the fire alarm industry. Today, we arethe largest manufacturer of engineered fire alarm systems with over 400 distributorsworldwide, and regional support operations on every continent to ensure we providethe flexibility and options your business needs.

NOTIFIER - Leaders in Life. Safety. Technology.

NOTIFIER10 Whitmore Road, WoodbridgeOntario L4L 7Z4 CanadaTel: 1-905-856-8733 Toll Free: 1-888-289-1114Fax: 1-905-856-9687For additional offices in Canada, visit www.notifier.com

All NOTIFIER products in this catalogue are ULC listed.