CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUGARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
A11 of 30
Not Drawn to Scale
LOCATION PLAN
3
this Site
Not Drawn to Scale
VICINITY MAP
3
this Site
BUILDING OFFICIAL
LAND USE AND ZONING
LINE AND GRADE
ARCHITECTURAL
STRUCTURAL
SANITARY
ELECTRICAL
MECHANICAL
REPUBLIC OF THE PHILIPPINESDEPARTMENT OF PUBLICWORKS AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL CITY OF ILIGAN
FIRE SAFETY
A11. PERSPECTIVE VIEW2. VICINITY MAP3. LOCATION PLAN
A21. GROUND FLOOR PLAN2. SECOND FLOOR PLAN3. THIRD FLOOR PLAN4. LEFT ELEVATION5. RIGHT ELEVATION'
A31. ROOFDECK FLOOR PLAN2. FRONT ELEVATION3. REAR ELEVATION4. SECTION THRU - C5. SECTION THRU - D6. SECTION THRU - L
A41. SECTION THRU - A2. SECTION THRU - B3. GRND FLR REFLECTED CEILING PLAN4. SECTION THRU - E5. SECTION THRU - F
A51. 2ND FLR REFLECTED CEILING PLAN2. 3RD FLR REFLECTED CEILING PLAN3. RFDCK REFLECTED CEILING PLAN4. CEILING FRAME DETAIL5. DRY WALL FRAME DETAIL
A61. GLASS PARTITION DETAIL2. SCHEDULE OF WINDOWS
A71. SCHEDULE OF DOORS2. POLYCARBONATE ENCLOSURE DETAIL3. POLYCARBONATE CANOPY DET.4. POLYCARBONATE CANOPY FRAMING DET.
S11. FOUNDATION PLAN2. SECOND FLOOR FRAMING PLAN3. THIRD FLOOR FRAMING PLAN4. COMBINED FOOTING 1 (CF-1) DETAIL3. COMBINED FOOTING 4 (CF-4) DETAIL
S21. ROOFDECK FRAING PLAN2. ROOF BEAM PLAN3. ROOF FRAMING PLAN4. COMBINED FOOTING 2 (CF-2) DETAIL5. COMBINED FOOTING 3 (CF-3) DETAIL
S31. COMBINED FOOTING 5 (CF-5) DETAIL2. WALL FOOTING DETAIL3. COLUMN DETAIL4. TIE BEAM TRANSVERSE STRUCTURE PROFILE5. TIE BEAM DETAIL
S41. SCHEDULE OF BEAMS - 1
S51. SCHEDULE OF BEAMS - 2
S61. SECOND FLOOR SLAB DETAIL2. CONCRETE CANOPY DETAIL3. CONCRETE GUTTER DETAIL
S71. MAIN STAIR SECTION2. MAIN STAIR DETAIL3. MAIN STAIR PLAN4. MAIN STAIR PROFILE5. SIDE STAIR PROFILE6. SIDE STAIR LANDING SECTION7. SIDE STAIR LANDING PLAN8. SIDE STAIR DETAIL9. TYPICAL STEEL HAN DRAIL DETAIL
S81. ELEVATOR SHAFT FOOTING PLAN2. ELEVATOR SHAFT FOOTING SECTION3. ELEVATOR SHAFT WALL DETAIL4. ELEVATOR SHAFT LAYOUT PLAN5. ELEVATOR SHAFT ROOF DETAIL6. PLANTED COLUMN DETAIL7. FOLDED SLAB DETAIL
S91. STEEL STAIR DETAIL2. WATER TANK PLATFORM DETAIL3. STEEL TRUSS 1 (T-1) DETAIL4. STEEL TRUSS 2 (T-2) DETAIL5. STEEL TRUSS 3 (T-3) DETAIL6. STEEL TRUSS 4 (T-4) DETAIL
P11. GRND FLR DRAINAGE SYSTEM LAYOUT PLAN2. 2ND FLR DRAINAGE SYSTEM LAYOUT PLAN3. 3RD FLR DRAINAGE SYSTEM LAYOUT PLAN4. RIGHT WING PIPING ISOMETRIC DIAGRAM
P21. ROOFDECK DRAINAGE SYSTEM LAYOUT PLAN2. GRND FLR WATER SUPPLY LAYOUT PLAN3. 2ND FLR WATER SUPPLY LAYOUT PLAN4. LEFT WING PIPING ISOMETRIC DIAGRAM
P31. 3RD FLR WATER SUPPLY LAYOUT PLAN2. ROOFDECK WATER SUPPLY LAYOUT PLAN3. GRND FLR STORM DRAINAGE LAYOUT PLAN4. DIRECTOR'S OFFICE PUMBING LAYOUT PLAN5. FACULTY LOUNGE PLUMBING LAYOUT PLAN
P41. BLOWN UP PLUMBING LAYOUT PLAN
P51. CISTERN DETAIL2. SEPTIC VAULT DETAIL3. LOCATION PLAN
M11. GRND FLR FIRE ALARM SYSTEM LAYOUT PLAN2. 2ND FLR FIRE ALARM SYSTEM LAYOUT PLAN3. 3RD FLR FIRE ALARM SYSTEM LAYOUT PLAN4. FIRE ALARM SYSTEM RISER DIAGRAM5. FIRE ALARM SYSTEM ELEMENTARY DIAGRAM
M21. RFDCK FIRE ALARM SYSTEM LAYOUT PLAN2. ELEVATOR HOISTWAY PIT PLAN3. ELEVATOR HOISTWAY LANDING PLAN4. ELEVATOR HOISTWAY OVERHEAD PLAN5. ELEVATOR HOISTWAY SECTION
E11. GRND FLR POWER CIRCUIT LAYOUT PLAN2. 2ND FLR POWER CIRCUIT LAYOUT PLAN3. 3RD FLR POWER CIRCUIT LAYOUT PLAN
E21. RFDCK POWER CIRCUIT LAYOUT PLAN2. GRND FLR LIGHTING CIRCUIT LAYOUT PLAN3. 2ND FLR LIGHTING CIRCUIT LAYOUT PLAN4. SCHEDULE OF POWER & LIGHTING LOADS
E31. 3RD FLR LIGHTING CIRCUIT LAYOUT PLAN2. RFDCK LIGHTING CIRCUIT LAYOUT PLAN3. GRND FLR INTERCOM LINE LAYOUT PLAN4. SCHEDULE OF ACU & SUBFEEDER LOADS
E41. 2ND FLR INTERCOM LINE LAYOUT PLAN2. 3RD FLR INTERCOM LINE LAYOUT PLAN3. RFDCK INTERCOM LINE LAYOUT PLAN4. GROUNDING PLAN5. LIGHTNING ARRESTER PLAN6. ELECTRICAL RISER DIAGRAM
E51. GRND FLR ACU OUTLET LAYOUT PLAN2. 2ND FLR ACU OUTLET LAYOUT PLAN3. 3RD FLR ACU OUTLET LAYOUT PLAN4. ELECTRICAL SINGLE LINE DIAGRAM5. TELEPHONE LINE RISER DIAGRAM6. INTERCOM LINE RISER DIAGRAM
E61. TYPICAL CABLE TRAY LADDER LAYOUT PLAN2. CABLE TRAY LADDER DETAIL3. LOCATION PLAN
Scale: 1:250 m
GROUND FLOOR PLAN
1
Scale: 1:250 m
SECOND FLOOR PLAN
2
Scale: 1:250 m
THIRD FLOOR PLAN
3
Scale: 1:100 m
LEFT ELEVATION
4
Scale: 1:100 m
RIGHT ELEVATION
5
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUGARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
A22 of 30
Scale: 1:250 m
FRONT ELEVATION
2
Scale: 1:250 m
REAR ELEVATION
3
Scale: 1:100 m
SECTION THRU - L
6
Scale: 1:100 m
SECTION THRU - C
4
Scale: 1:100 m
SECTION THRU - D
5
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUGARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:250 m
ROOFDECK FLOOR PLAN
1
A33 of 30
Scale: 1:250 m
SECTION THRU - A
1
Scale: 1:250 m
SECTION THRU - B
2
Scale: 1:100 m
SECTION THRU - E
4
Scale: 1:100 m
SECTION THRU - F
5
Scale: 1:250 m
GRND FLR REF CEILING PLAN
3
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUGARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
A44 of 30
CEILING FRAME ISOMETRIC VIEW
DRY WALL FRAME ISOMETRIC VIEW
Scale: 1:30 m
CEILING FRAME DETAIL
4
Scale: 1:30 m
DRY WALL FRAME DETAIL
5
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUGARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:250 m
2ND FLR. REF. CEILING PLAN
1
Scale: 1:250 m
3RD FLR. REF. CEILING PLAN
2
Scale: 1:250 m
RF.DCK. FLR. REF. CEILING PLAN
3
A55 of 30
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUGARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:30 m
GLASS PARTITION DETAIL
1
Scale: 1:25 m
SCHEDULE OF WINDOWS
2
A66 of 30
Scale: 1:50 m
POLYCARBONATE ENCLOSURE DETAIL
2
AT 2ND FLR. SIDE STAIR PLAN AT 3RD FLR. SIDE STAIR PLAN AT RF DECK SIDE STAIR PLAN
LOBBY ENCLOSURE PLAN
FASCIA FRAMESECTION
CT-2SECTION
CT-1 SECTION
CT-1TOP VIEWCT-1 SECTION
Scale: 1:25 m
POLYCARBONATE CANOPY FRAME DET.
3
FASCIA FRAMEDET.
PLYCARBONATE CANOPY FRAMING PLAN
PLYCARBONATE CANOPY FRAMING SECTION
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ARCHT. DANN PAULO C. LAYUGARCHITECT I, PHYSICAL PLANT DIVISION
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:25 m
POLYCARBONATE CANOPY FRAMING DET.
4
Scale: 1:25 m
SCHEDULE OF DOORS
1
A77 of 30