A Global Solution For Green Buildings.
®
www.GreenFumeHood.com
an product
2
GREENFUMEHOOD®
Safety, performance, energy savings and environmental protection
Exclusive Neutrodine®
molecular filtration technology
Smart hood embedded electronic intelligence
User access management
Front sash opening detection system
Under bench safety storage solutions
COSTS SAVINGS SAFETY
Tested in accordance with : • AFNOR NF X 15 211• EN 14175-3• ASHRAE 110:1995
• Eliminates air supply and extraction systems
• Very low energy consumption• Low operating costs• Reduced investment cost
• Standalone system, no ductwork required
• Flexibility in lab planning• Easy to relocate
• No pollutants released into the atmosphere
• Eliminates CO2 emissions linked to energy production
MOBILITY ENVIRONMENT
Exclusive real time filtration performance monitoring technology
Adaptable Modular Filtration Column
(AMFC™ )
HEPA H14 Particulate filtration
g-Guard® fume hoodmonitoring software
(optional)
Temperature alert sensor
Model shown : GFH 6400
Filters radio frequency identification (RFID)
GreenFumeHood®
a concentration
of innovative
and exclusive
technologies
3
ENERGY AND COSTS SAVINGS
How does your fume hood compare ?
Compare infrastructure and operating costs of your ducted fume hood with a GreenFumeHood® solution.
Annual energy cost*
Annual filters replacement
cost**
Makeup air and air
conditioning
Building - Infrastructure
- Planning
Annual maintenance
cost***
Total average annual
operating cost
GFH 4200460 m3/h < 20 € 542 €
0 € for GFH
(limited to the min. volume required by local regulations)
0 €
330 € 892 €
GFH 5300690 m3/h < 25 € 814 € 330 € 1169 €
GFH 6400920 m3/h < 30 € 1085 € 400 € 1515 €
GFH 75001150 m3/h < 40 € 1357 € 400 € 1797 €
Your fume hood
HVAC filters
Your annual total
* : Estimation cost based on the average cost of electricity for industrial use in France : 0,06 euros / 8 h per day for 220 days per year.** : Noticed average filter replacement frequency : 18 months.*** : Max. cost without filters replacement for 1 unit / Optimized cost starting from two units located at the same site.
A study by Lawrence Berkeley National Labs (LBNL) has concluded : - ‘‘The energy needed to fuel the average fume hood costs over $4,300 per year”.
- “A typical fume hood runs 24 hours a day…and uses 3.5 times more energy than the average house.”*
(Bell et Al 2003) Harvard Green Campus Initiative, (LBNL 2002)
4
FILTRATION
High performance filtration technologies
Neutrodine®, a single molecular filter for all chemicals
• Allows the simultaneous handlings of solvents, acids and bases with the same filter.
• High retention capacities for an unprecedented level of safety.
• Unique formulation, without carbon mixing.
• No heavy metal impregnation used
Adaptable Modular Filtration Column (AMFC™) • Appropriate for use during large variety laboratory
procedures. • Enables the handling of liquid and powder chemicals.• Quick and easy reconfiguration by simply swapping out
filters.
Revolving filter System : safer, optimized & environmentally engineered
Powder filtration • High-efficiency HEPA filters used are H14 type
filters, in accordance with standard EN 1822-1• 99.995% global filtration efficiency for particles
over 0.1 micron in size.
Neutrodine®
filter versatilityDedicated filters
Neutrodine® filters performance tests according to the AFNOR NF X 15-211 standard
For liquids For liquids + powders
For cleanrooms
Safety back-up Neutrodine® filter
Ventilation - Detection module
Main Neutrodine®
filter
HEPA H14Filter
Lighting & Prefiltration module
Horizontal Modularity : US patent number 7,766,732
Molecular filter for solvents
Molecular filter for acids
Molecular filter for bases Simultaneous
chemicals handling
Bas
es
Bas
es
Aci
ds
Aci
ds
Solv
ents
Solv
ents
Isopropyl Alcohol
HCl (35%) Ammonia
3365 gr 13645 gr 1920 gr
Neutrodine® filters retention capacities (Tests performed with a GFH® 7500)Anti carbon shifting filter system : US patent
number 7,563,301
Neutrodine® filter: US patent application
number 12/465,434 (patent pending)
A PATENTED INNOVATION
• « Class 1 » Filtration Column with two filtration levels: 1 main level + 1 safety back-up level.
• Revolving Filtration System allows the renewal of one filtration level while optimizing main filter lifetime.
• No pollutant released into the laboratory in case of main filter saturation.
New Neutrodine®
filter
Revolving Filter system
Used Neutrodine®
filter Safe environmental disposal
and energy recovery
5
DETECTION
An exclusive molecular filter saturation detection system
The exclusive GreenFumeHood® filtration saturation detection system is designed with 3 specific sensors
for the detection of a large spectrum of molecules
Solvents detection sensor
• Filter saturation detection above main filter level. • Adjustable sensitivity according to handled molecules.• Monitoring and traceability data via g-Guard® software.
Acids detection sensor
• Filter saturation detection above main filter level. • Monitoring and traceability data via g-Guard® software.
Laboratory air quality sensor
• Located on the fume hood front panel.• Detects laboratory ambient air pollution.
If main filter is saturated, an alarm is triggered and the safety back-up filter ensures maximum user protection.
Handling in progress can be safely continued without risk to the operator.
1
2
1 2
3
3
6
SAFETY
Users protection
Secured filter installation and replacement process.
Filter identification by RFID technology
• Filter type identification (HEPA or Neutrodine®).• Serial number identification.• Filter installation and expiration recording. • Prevents from saturated filter reinstallation risks. • Monitoring and traceability datas via g-Guard® software.
Access control management
Simplified preventive maintenance : Step by step screen guided filters replacement procedure.
UserSafe and simple use of the unit
AdministratorData access logs
Replacement filters menuUsage parameters access
MaintenanceTotal access to all control and operational
GreenFumeHood® parameters.
• Access management by RFID technology. • 3 level access rights.
7
SAFETY
Users protection
Fire prevention sensor
• Temperature detection and alert system
• This system provides two detection levels - A first alert is triggered when the temperature reaches 60°C and remains steady - A second alarm is activated when the temparature into the enclosure reaches 80°C and triggers all fans to stop.
• Detects unusual temperature elevations into the enclosure.
• Controlled via g-Guard® software: an alert is displayed on the hood screen and transmitted to the monitoring PC.
Containment safeguard : Sash position detection
• Blower speed proportionally adapted to the sash opening height.
• Guarantee of the air face velocity > 0,4m/s-1 (according to the AFNOR NF X 15-211 standard).
• Statistics data usage via g-Guard® software.
• Alarm triggered when the sash height opening is beyond safety limits.
Fan Failure alarms
• Individual and real time fan monitoring.
• Alarm triggered in case of fan failure. Display of specific fan involved.
• Each operational fan parameters are displayed on the hood screen and via g-Guard® software.
SASHOK
SASH OK
SASH too high
8
COMMUNICATION
The embedded electronic system enables GreenFumeHood®
to become a real and safe communicating tool
Fume hood network management
g-Guard® software, an innovative technology which allows :
• Networking of GreenFumeHood® units.• Network remote management from a PC.• Receiving real time safety alerts.• Preventive maintenance optimization.
Monitoring, management and statistics :
GreenFumeHood® embedded computer associated withg-Guard® software offers «real time» monitoring. g-Guard® gives access to the following safety information and updates :
• Usage authorisation.• Filter usage. • Neutrodine® filters saturation detection.• Filters identification. • Sash position.• Blower speed.• Pollution of the laboratory air.• Temperature in the enclosure.• Usage statistics.
Choose your GreenFumeHood monitoring technique :
- Network management via g-Guard® can be installed on any PC.
- Network management can also be remotely managed by Erlab maintenance via our g-Guard® online service (optional service).
The exclusive g-Guard® communication system offers laboratory managers and safety officers real time access and remote management capabilities
linked to the safety of their fume hood network.
9
COMMUNICATION
Go further with g-Guard® software by creating a direct link between any GreenFumeHood® and the safety, s and facilities management.
Many other features are accessible through g-Guard®.
General and real time view of your fume hood network .
Quick access to all ventilation operational parameters.
Real Time telemetry of all vital elements.
Anticipate maintenance operations.
Access to solvent sensor sensistivity parameters.
Chronological traceability of usage parameters.
Usage optimization statistics.
Send safety alerts to a GreenFumeHood screen from any supervision PC.
10
STANDARDS
Containment
EN 14175-3 European Standard
EN 14175-3 European Standard
ASHRAE 110:1995 American Standard
ASHRAE 110:1995 American Standard
A very high containment level guaranteed by the most stringent standards.
Enclosure containment efficiency
It is defined by the fume hood capacity to maintain chemical vapors within the enclosure without any propagation in the laboratory environment.
Containment efficiency proven by protocols described in the EN14175-3, ASHRAE 110:1995 and AFNOR NF X 15-211 standards.
Containment standards tests applied to a GreenFumeHood® are identical
to a ducted fume hood.
Download the complete version of our containment test reports on www.greenfumehood.com
Reached performance criteria : < 0,1 ppm of SF6
Reached performance criteria : < 0,1 ppm of SF6
11
STANDARDS
Filtration
A safety standard for filtration fume hoods
Filtration efficiency according to the most stringent standard : AFNOR NF X 15-211
The Neutrodine® filtration system is compliant with NF X 15-211, the stringent industry standard developed by a committee of independent scientists and manufacturers specializing in filtration and safety.
The standard establishes stringent performance criteria at 100 times below the authorized TLV/OEL levels for the quality of the filtered air as monitored after the second layer of Neutrodine filtration media that a fume hood operator must be able to breathe during their professional lifetime without encountering any health risks.
Solvent test Acid test
Download the complete version of our filtration test reports on www.greenfumehood.com
Reached filtration performance criteria : < 1% of TLV / OEL
Reached filtration performance criteria : < 1% of TLV / OEL
12
ENVIRONMENT
GreenFumeHood® optimizes your ‘‘environmental’’ strategy.
Compared to ducted fume hoods, GreenFumeHood® eliminates air pollutant emissions into the atmosphere.
Production:Plant based carbon
Neutrodine filter incineration
CO2 Consumption for plant growing.
Absorption by photosynthesis
CO2
CO2
Neutrodinemanufacturing
Usage: Preventing air contamination
An environmentally friendly lifecycle
GreenFumeHood® for a sustainable laboratory use :
• Eliminates ducted fume hood huge energy consumption.
• Eliminates direct emissions of pollutants into the atmosphere.
Neutrodine®, a green engineered filter :
• Natural based raw material designed to integrate the recycling cycle.
• Environmentally neutral non toxic impregnation agents used.
• Environmentally safe disposal process.
Not anym
ore
GreenFumeHood® concentrates technologies offering a real alternative to ducted fume hoods.
13
RANGE & EQUIPMENT
Ergonomic and operational solutions
Energy utility module For electrical and IT
integration
Rear technical access panel
(Optional)
G-Station base stand with built-in energy
and/or water gas horizontal utility module (optional)
Water, gas and vacuum utility
module
Side and back clear panels
(Optional)
Laboratory rack Built in support
for structural rods (Optional)
Under bench filtered or non filtered safety
storage solutions (Optional)
Work surface adapted to a large variety of handlings including precise
weighing
A large choice of dimensions and retention capacities
Equipment engineered to serve your lab activity
768 mm1225 mm
GFH 42002 filtration columns
979 mm1433 mm
3 filtration columns
GFH 5300
1386 mm1849 mm
4 filtration columns
GFH 6400
1810 mm
2265 mm
5 filtration columns
GFH 7500
968 mm
1590 mmmini
1673 mmmaxi
Side view
Side view
948 mm
80mm
902 mm
764 mm
14
LAB PLANNING
GreenFumeHood® greatly simplifies your laboratory design project
Mobility and flexibility
• All encompassing system, autonomous and mobile : does not require any external ducting system.• Can be easily and quickly adapted to any relocation laboratory projects.
Simplified laboratory design
• Standalone fume hood concept.• No impact on laboratory air balance.• Can be integrated at any time during
the lab design or renovation phases. • Limited planning.• No ductwork.• Simple relocation.
GreenFumeHood® evolving with the laboratory
• Covers the majority of laboratory handlings• Large range of sizes adaptable to the laboratory’s ergonomic needs.• For new, renovated or restructured labs.• Simple and quick filtration column reconfiguration adapted to laboratory
handling evolutions.
Easy set-up
• With its precision engineering and robust construction, GreenFumeHood® Technology can be quickly and easily set up.• Immediately available when installed : does not require ductwork.
A flexible investment adapted to future needs.
15
SERVICES
A set of services for project, set-up and maintenance
Project Study
• A team of specialists dedicated to your projects. • Feasability study written certification. • Pay-back report.
Maintenance
• Our Asura® department and our licensed partners network are at your service for the maintenance of your GreenFumeHood®.
• Maintenance protocoles compliant with all safety standards.
• Training of your maintenance technicians.
GreenFumeHood® services assisting you at each step of your laboratory project.
• g-Guard® Online : Network management can be remotely managed by our Asura® maintenance department.
(Optional service - Available only through a personnalized study)
A Global Solution For Green Buildings.
®
EuropeErlab D.F.S. S.A.S.
Parc d’Affaires des Portes – BP403 27104 Val de Reuil Cedex - France
Tel : +33 (0) 2 32 09 55 80 Fax : + 33 (0) 2 32 09 55 90
e-mail : [email protected]
USA Erlab Inc.
388 Newburyport Turnpike Rowley, MA 01969 - USATel : +1 (978) 948-2216Fax : +1 (978) 948-3354
e-mail : [email protected]
AsiaKunshan erlab D.F.S. co Ltd
100 Liu Shi Jing, road Kunshan Development Zone
Jiangsu ProvincePenglang
P.R China 215333Tel : +86 (0) 512 5781 4085Fax : + 86 (0) 512 5781 4082
e-mail : [email protected]
www.GreenFumeHood.com
an productGreenFumeHood® and Neutrodine® are registered trademarks of Erlab. Microsoft, Windows and the Windows logo are registered trademarks of Microsoft Corporation in the United States and/or in other countries ; any use of such marks by Erlab® is under license. All data or photographs in this brochure are not contractual.