The setting of hard-wired emergencystop function of FANUC LASER
C4000i-MODEL B NRTL specification
1/1FANUC LTD
A-81053E-195
DescriptionDesignDateEdit.
01 071015 T.WATANABE
Title
Sheet
Draw. No.
The setting of hard-wired emergency stop function
of FANUC LASER C4000i-MODEL B NRTL specification
1.
OutlineShort piece that invalidates the hard-wired emergency stop function is installed in the
FANUC LASER C4000i-MODEL B NRTL specification that has already been shipped (The oscillator
of following serial number). Therefore, remove short piece when you install the machine as
well as the current United States specification.
2. Applied oscillator
The objects are oscillators of the following serial number.
Serial number O/S number
L07440737 (manufactured in April, 2007) CS40001
L07540806 (manufactured in May, 2007) AD50953
L07640872 (manufactured in June, 2007) AD50981L07740934 (manufactured in July, 2007) YA83678
L07840989 (manufactured in August, 2007) YA84081
L07900041 (manufactured in September, 2007) YE08328
The oscillator manufactured after the above-mentioned removes short piece.
3. Setting
Remove the short piece that connects ESP1 with ESP2 of terminal block TL3 on IF-PCB as
shown in the figure below.
ESP2
ESP1
Loosen the screws of ESP1 and
ESP2, detach short piece, and
tighten these screws.
Short piece
TL3