Ericsson RBS 6000 Sync Alarm Hello, what parameters the Ericsson RBS 3G BST expect so if the synch is being done only via Ethernet works with no issues, we are using minlink radios to backhaul and we have no issues but we use radios from other providers a synch alarm related to the quality of the clock triggers, where can I find synch information and how it works at the NTP level. Re: Ericsson RBS 6000 Sync Alarm Hi, are the refered RBS GPB or CBU based? The clock extraction in the GPB is less robust than in the CBU, you can find some info about this in alex documentation. The limits in the transmission variation delay are more tolerated in the CBU. There are a counter pm...VariationDelay to evaluate this possible problem in the IP transmission solution. Re: Ericsson RBS 6000 Sync Alarm Hello Laser Now that I read my post...it's not really clear. We are using a Ericsson 6102 3G BST all this is all new to me, I'm not really in charge of the 3G BST but I would like to understand why we are getting alarms. Let me explain with more detail, we are using all IP connectivity to the BST so the synch is traveling in the transport network as NTP messages, thats what I understand from Ericsson (I don't have Alex access) when the MiniLink radios are used as backhaul all is good and no synch alarms appear, as soon as we change the backhaul for other radios we get the alarm: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=CRHER1R.MeContext=BST400 Severity:Major Event Type: Quality of service alarm ProbableCause: Clock synchronisation problem specificProblem:Synch Reference Not Reliable managedObjectClass: Synchronization managedObjectinstance: ManagedElement=1, TransportNetwork=1,Synchronization=1 after few seconds later we get the System Clock in Holdover mode as the synch is lost. When we compare the latency and jitter of both radios, the Minilink and the other radio both have similar response times, so we are trying to figure out what is causing the synch alarm to trigger.

83603645 Ericsson RBS 6000 Sync Alarm

  • Upload
    cepillo

  • View
    287

  • Download
    9

Embed Size (px)

DESCRIPTION

ricsson RBS 6000 Sync Alarm

Citation preview

Page 1: 83603645 Ericsson RBS 6000 Sync Alarm

Ericsson RBS 6000 Sync Alarm

Hello, what parameters the Ericsson RBS 3G BST expect so if the synch is being done only via

Ethernet works with no issues, we are using minlink radios to backhaul and we have no issues

but we use radios from other providers a synch alarm related to the quality of the clock triggers,

where can I find synch information and how it works at the NTP level.

Re: Ericsson RBS 6000 Sync Alarm

Hi, are the refered RBS GPB or CBU based?

The clock extraction in the GPB is less robust than in the CBU, you can find some info about this

in alex documentation. The limits in the transmission variation delay are more tolerated in the

CBU.

There are a counter pm...VariationDelay to evaluate this possible problem in the IP transmission

solution.

Re: Ericsson RBS 6000 Sync Alarm

Hello Laser

Now that I read my post...it's not really clear.

We are using a Ericsson 6102 3G BST all this is all new to me, I'm not really in charge of the 3G

BST but I would like to understand why we are getting alarms.

Let me explain with more detail, we are using all IP connectivity to the BST so the synch is

traveling in the transport network as NTP messages, thats what I understand from Ericsson (I

don't have Alex access) when the MiniLink radios are used as backhaul all is good and no synch

alarms appear, as soon as we change the backhaul for other radios we get the alarm:

SubNetwork=ONRM_ROOT_MO_R,SubNetwork=CRHER1R.MeContext=BST400

Severity:Major

Event Type: Quality of service alarm

ProbableCause: Clock synchronisation problem

specificProblem:Synch Reference Not Reliable

managedObjectClass: Synchronization

managedObjectinstance: ManagedElement=1, TransportNetwork=1,Synchronization=1

after few seconds later we get the System Clock in Holdover mode as the synch is lost.

When we compare the latency and jitter of both radios, the Minilink and the other radio both

have similar response times, so we are trying to figure out what is causing the synch alarm to

trigger.

Page 2: 83603645 Ericsson RBS 6000 Sync Alarm

About your question Laser, about who extracts the clock is hard to say, I don't know if it's the

GPB or the CBU, how can I now? only via configuration?

I'm by no means expert on Ericsson..not even a Junior..just plain new.

Now because of this issue we capture some packets and we discover that the NTP packets are

just plain wrong, please help me to understand how the Ericsson BST synch with the RNC when

it's done via NTP.

I have to move...but later I will post the NTP server packet.

THank you for your insight.

Any help or docs that can help to understand this synch process is much appreciated.

Re: Ericsson RBS 6000 Sync Alarm

I'm adding the NP server frame here:

Frame 6: 94 bytes on wire (752 bits), 94 bytes captured (752 bits)

Ethernet II (VLAN tagged), Src: Cisco_6c:6b:80 (c4:7d:4f:6c:6b:80), Dst: MasterIn_c2:67:78

(00:1e:df:c2:67:78)

Internet Protocol Version 4,

User Datagram Protocol, Src Port: ntp (123), Dst Port: 65501 (65501)

Network Time Protocol

Flags: 0x24 00.. .... = Leap Indicator: no warning (0)

..10 0... = Version number: NTP Version 4 (4)

.... .100 = Mode: server (4)

Peer Clock Stratum: primary reference (1)

Peer Polling Interval: invalid (0)

Peer Clock Precision: 67108864.000000 sec

Root Delay: 0.0000 sec

Root Dispersion: 0.0000 sec

Reference ID: Generic pulse-per-second

Reference Timestamp: Jan 1, 1970 00:00:00.000000000 UTC

Origin Timestamp: Not representable

Receive Timestamp: Not representable

Transmit Timestamp: Not representable

Please note the values in Peer clock precision.

And the BST reply to this packet:

Frame 728: 94 bytes on wire (752 bits), 94 bytes captured (752 bits)

Page 3: 83603645 Ericsson RBS 6000 Sync Alarm

Ethernet II (VLAN tagged), Src: MasterIn_c2:67:78 (00:1e:df:c2:67:78), Dst: All-HSRP-

routers_04 (00:00:0c:07:ac:04)

User Datagram Protocol, Src Port: 65501 (65501), Dst Port: ntp (123)

Network Time Protocol

Flags: 0x23

00.. .... = Leap Indicator: no warning (0)

..10 0... = Version number: NTP Version 4 (4)

.... .011 = Mode: client (3)

Peer Clock Stratum: unspecified or invalid (0)

Peer Polling Interval: invalid (0)

Peer Clock Precision: 1.000000 sec

Root Delay: 0.0000 sec

Root Dispersion: 0.0000 sec

Reference ID: NULL

Reference Timestamp: Jan 1, 1970 00:00:00.000000000 UTC

Origin Timestamp: Jan 1, 1970 00:00:00.000000000 UTC

Receive Timestamp: Jan 1, 1970 00:00:00.000000000 UTC

Transmit Timestamp: Not representable

Re: Ericsson RBS 6000 Sync Alarm

The RBS6102 is the latest HW outdoor, so at least it should have the same performance has the

CBU based RBSs.

In solution that I now the RNC is the NTP server and the RBS (GPB, CBU or in this case DUW)

extracts the CLK from IP frames (see attach).

The most interesting counter to see the performance of this sync solution is this one:

"pmMaxDelayVariation:This counter shows the Maximum Delay Variation (see ITU-T Y.1540

for definition of the delay variation) experienced by the active IP synchronization reference

during the PM interval.

Condition: This counter is calculated on the basis of maximum and minimum packet delays for

the active IP reference at the end of each GP, as follows:

Max Delay Variation = Max Packet Delay - Min Packet Delay"

Ask the guys from radio dpt to get this counter for a few IP based RBS's working and with

problems and check the differences, you will see the "good" and the "bad" transmission solution.

Re: Ericsson RBS 6000 Sync Alarm

Hello LaserSport!!

This indeed is gold! Thank you so much for pointing me in the right direction, with this

Page 4: 83603645 Ericsson RBS 6000 Sync Alarm

specifications and the statistics in the RBS now I now what KPI to watch.