Marine Cables 8/2010

8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

Marine Cables8/2010

Page 2: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

Helkama – a true specialistin marine cables ......................2Approvals..................................30,6/1kV cablesLKM-HF.....................................4LKM-HF FLEX ...........................6LKMM-HF NEW .........................8LKSM-HF.................................10LKSM-HF FLEX .......................12LKMSM-HF NEW.....................14LKSM-EMC..............................16LKSM-VFD ..............................18LKAM-HF.................................20LKEM-HF.................................220,6/1kV FR cables

LKM-FRHF...............................24LKSM-FRHF ............................26LKAM-FRHF ............................28250V cablesLKM-HF NEW ..........................30LKSM-HF.................................32LKAM-HF NEW ........................34RFE-HF ....................................36RFE-HF (i) ...............................38RFA-HF....................................40RFA-HF (i) ...............................42250V FR cables

LKM-FRHF NEW ......................44LKSM-FRHF NEW....................46LKAM-FRHF NEW....................48RFE-FRHF................................50RFE-FRHF (i) ...........................52RFA-FRHF................................54RFA-FRHF (i) ...........................5660V cablesPBS .........................................58Optical fibre cablesFXMSU....................................60FXMMS ...................................61LifeCord-FRHF.........................62Cabled optical fibrescharacteristics .........................63Technical informationGeneral information.................64Bending radius ........................65Diameter tolerance ..................65Core identification ...................65Current rating..........................66Short circuit current ................66Short time duty .......................67Short circuit factors.................68Voltage drop............................69

Contents

Helkama is specializing in development and production of

marine cables. Our experience in this field goes back more

than thirty years. Our high technical quality has been achieved

by continuous development work support by our clients. In

this catalogue we proudly present our most comprehensive

range of marine cables.

We have chosen to produce only halogen-free cables. They

remarkably improve the fire safety of the ships by not emitting

toxic burning fumes or thick smoke. In addition no corrosive

gases damaging the ship and its equipment are emitted in

case of a fire. Using the latest technology we have been able

to reduce cable weight and size to a minimum and still

maintain quality as well as enabling easy and fast installation.

The halogen free range of cables includes both flame-retardant

(IEC 60332-3) and fire resistant (IEC 60331-21) cables.

Helkama marine cables are approved by all major classification

societies.

As a specialized and independent

company, focusing on service, we have

been able to grow steadily by quickly

responding to our customers’ needs.

Our short delivery times, backed up by

extensive stocks, enable us to deliver

punctually and keep our clients satisfied.

This remains our goal for the future, too.

HELKAMA – a true specialist in marine cables

Marine cable factory inKaarina, Finland.

Page 3: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

ww

w.h

elk

am

ab

ica.fi

3TY

PE A

PP

RO

VA

LS

Marine cable factory inShanghai, China.

● Combined TAC for Finland and China ● ● Separate TAC for Finland and China ❍ Type Approval pending No Type Approval

Please check updated approval situation on www.helkamabica.fi

Type Approval Certificates for factories in Finland and China

ABS BV CCS DNV GL KRS LRS RMRS NK RINA TC

0,6/1kV FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

LKM-HF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  LKM-HF FLEX ● ● ● ❍ ❍ ● ● ● ❍ ● ● ● ● ● ● ❍ ●    LKSM-HF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  LKSM-HF FLEX ● ● ● ❍ ❍ ● ● ● ❍ ● ● ● ● ● ● ❍ ●    LKSM-EMC ● ● ● ● ● ● ❍ ❍      LKAM-HF ● ● ● ❍ ● ● ● ● ● ❍ ● ❍ ●    LKEM-HF ● ● ● ❍ ❍ ● ● ● ❍ ● ● ● ● ● ● ● ● ●    LKM-FRHF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  LKSM-FRHF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  LKAM-FRHF ❍ ❍ ❍ ❍ ❍ ● ❍ ❍ ● ● ❍ ● ❍ ●    LKMM-HF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●    LKMSM-HF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●    1,8/3kV FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

LKSM-VFD ● ❍ ● ● ● ❍ ❍      250V FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

LKM-HF ❍LKSM-HF ● ● ● ● ● ● ● ● ● ● ❍ ● ● ●    LKAM-HF ❍LKM-FRHF ❍LKSM-FRHF ❍LKAM-FRHF ❍RFE-HF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  RFE-HF(i) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  RFA-HF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●    RFA-HF(i) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●    RFE-FRHF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  RFE-FRHF(i) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●  RFA-FRHF ● ● ● ● ● ● ● ● ● ● ❍ ● ● ●    RFA-FRHF(i) ● ● ● ● ● ● ● ● ● ● ❍ ● ● ●    60V FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN

PBS ❍

Page 4: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

40

,6/1

kV

CA

BLE

S

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

LKM-HF Unarmoured power and control cable0,6/1kV

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission8

/20

10

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Page 5: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

50

,6/1

kV

CA

BLES

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

LKM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

25642 – 1x6 7,0 95 52 3025644 – 1x10 8,0 140 72 3525646 – 1x16 9,0 205 96 4025648 – 1x25 11,5 320 127 5025650 – 1x35 12,5 420 157 5025652 – 1x50 14,5 555 196 6025654 – 1x70 17,0 790 242 7025656 – 1x95 18,5 1040 293 7525658 – 1x120 20,5 1300 339 8525660 – 1x150 23,5 1610 389 9525662 – 1x185 26,0 2005 444 16025664 – 1x240 29,0 2615 522 17525666 – 1x300 31,5 3235 601 19025670 – 2x1,5 8,5 80 20 3525686 – 2x2,5 10,0 115 26 4025702 – 2x4 11,0 155 34 4525701 – 2x6 12,0 240 44 5025717 – 2x10 14,0 360 61 6025711 – 2x16 16,5 525 82 7025713 – 2x25 20,5 805 108 8525715 – 2x35 23,5 1100 133 9525671 25672 3x1,5 9,0 100 16 4025688 25689 3x2,5 10,0 145 21 4025703 25704 3x4 11,5 200 28 5025705 25706 3x6 13,0 305 36 5525707 25708 3x10 15,0 460 50 6025709 25710 3x16 17,5 680 67 7025712 25851 3x25 22,0 1045 89 9025714 25852 3x35 25,0 1425 110 15025716 25853 3x50 29,0 1910 137 17525718 25854 3x70 34,0 2740 169 20525720 25855 3x95 38,0 3600 205 23025722 25856 3x120 42,5 4525 237 25525724 25857 3x150 47,5 5585 272 28525673 25674 4x1,5 10,0 135 16 4025690 25691 4x2,5 11,0 180 21 4525725 25726 4x4 12,5 260 28 5025727 25728 4x6 14,0 375 36 6025729 25730 4x10 17,0 585 50 7025731 25699 4x16 19,5 875 67 8025732 25700 4x25 24,5 1355 89 10025733 25719 4x35 27,5 1825 110 16525734 25721 4x50 32,5 2460 137 19525735 25723 4x70 38,0 3515 169 23025984 25985 4x95 42,5 4670 205 25525879 --- 4x120 47,0 5820 237 28525676 25677 5x1,5 11,0 160 14 4525692 25693 5x2,5 12,0 220 18 5025864 25865 5x4 14,0 315 25 6025866 25867 5x6 15,5 465 30 6525868 25869 5x10 18,0 710 44 7525870 25871 5x16 21,5 1065 56 9025678 25679 7x1,5 12,0 200 12 5025694 25695 7x2,5 13,5 285 16 5525667 25668 10x1,5 15,0 290 11 6025993 25994 10x2,5 17,0 415 14 7025680 25681 12x1,5 15,5 335 10 6525696 25874 12x2,5 17,5 470 13 7025991 25992 14x1,5 16,4 375 10 7025995 25996 14x2,5 18,5 545 13 7525989 25990 16x1,5 17,5 425 9 7025997 25998 16x2,5 19,5 615 12 8025682 25683 19x1,5 18,5 490 9 7525873 25872 19x2,5 20,5 700 11 8525875 25876 24x1,5 22,0 635 8 9025877 25878 24x2,5 25,0 915 10 15025684 25685 27x1,5 22,5 690 8 9026141 26142 27x2,5 25,5 1005 10 15525675 25687 37x1,5 25,0 910 7 150

8/2

01

0

Page 6: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

60

,6/1

kV

CA

BLE

S8

/20

10

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 5

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

LKM-HF FLEX Unarmoured power cablewith flexible conductor0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.

Note! This cable is not designed for movable or portable applications.Flexible conductor cables ease the installation in areas involvingtight bending radius or high vibration.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 7: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

70

,6/1

kV

CA

BLES

8/2

01

0

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16

LKM-HF FLEX 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

25 647 – 1x16 9,0 190 94 4025 649 – 1x25 11,5 295 123 5025 651 – 1x35 12,5 390 153 5025 653 – 1x50 14,5 540 196 6025 655 – 1x70 17,0 725 240 7025 657 – 1x95 19,5 925 284 8025 659 – 1x120 21,5 1250 331 9025 661 – 1x150 24,5 1515 381 10025 663 – 1x185 27,0 1830 429 16525 665 – 1x240 30,5 2400 507 18526 047 – 1x300 33,0 3030 582 20026 054 – 2x16 16,5 450 80 7026 055 – 2x25 20,5 690 105 8526 056 – 2x35 23,0 945 130 9526 071 26 072 3x16 17,5 580 66 7526 073 26 074 3x25 22,0 890 86 9026 075 26 076 3x35 25,0 1310 107 10026 077 26 078 3x50 30,0 1730 137 18026 079 26 080 3x70 34,5 2385 168 21026 081 26 082 3x95 40,0 3160 199 24026 083 26 085 3x120 44,5 3885 232 27026 084 26 086 3x150 50,5 4710 267 30526 101 26 102 4x16 19,5 740 66 8026 103 26 104 4x25 24,5 1305 86 10026 105 26 106 4x35 27,5 1680 107 17026 107 26 108 4x50 33,0 2290 137 20026 109 26 110 4x70 38,0 3100 168 23026 111 26 112 4x95 45,0 4150 199 27026 113 26 114 4x120 49,5 5150 232 30026 131 26 132 5x16 21,5 910 55 9026 133 26 134 5x25 27,5 1440 71 165

5/2

00

9

Page 8: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

80

,6/1

kV

CA

BLE

S8

/20

10

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor 1,5–10mm2 IEC 60228, class2- stranded copper conductor 16–150mm2 IEC 60228, class5

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- extruded filler

4. Sheath- black polyolefine plastic, SHF1 IEC 60092-359

LKMM-HF Unarmoured power cablewith extruded filler0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 9: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

90

,6/1

kV

CA

BLES

8/2

01

0

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

LKMM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

27532 – 2x1,5 9,0 110 20 3527534 – 2x2,5 10,5 150 26 4027536 – 2x4 11,5 200 34 4027538 – 2x6 12,5 275 44 4527540 – 2x10 15,0 410 61 5527543 – 2x16 17,0 450 80 6527545 – 2x25 23,5 720 105 9027547 – 2x35 25,5 1000 130 15027549 – 2x50 30,0 1380 167 17527551 – 2x70 34,5 1885 204 20027564 27565 3x1,5 9,5 125 16 3527568 27569 3x2,5 11,0 180 21 4027572 27573 3x4 12,0 240 28 4527576 27577 3x6 13,5 340 36 5027580 27581 3x10 16,0 500 50 6027585 27587 3x16 18,5 595 66 7027589 27591 3x25 24,5 950 86 9527593 27595 3x35 27,5 1305 107 16027597 27599 3x50 32,0 1810 137 19027601 27603 3x70 37,0 2525 168 22027605 27607 3x95 43,0 3295 199 25527609 27611 3x120 47,5 4145 232 28027613 27615 3x150 54,0 5210 267 32027628 27629 4x1,5 11,0 160 16 4027632 27633 4x2,5 12,0 215 21 4527636 27637 4x4 13,5 295 28 5027640 27641 4x6 15,0 410 36 5527644 27645 4x10 17,5 625 50 6527649 27651 4x16 20,5 765 66 8027653 27655 4x25 27,0 1210 86 16027657 27659 4x35 30,0 1655 107 17527661 27663 4x50 35,5 2320 137 21027665 27667 4x70 41,0 3215 168 24027692 27693 5x1,5 11,5 190 14 4527696 27697 5x2,5 13,0 255 18 50

5/2

00

9

Page 10: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape

4. Armour- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

100

,6/1

kV

CA

BLE

S8

/20

10

LKSM-HF Armoured power and control cable0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 11: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

25742 – 1x6 3,1 8,0 130 52 5025744 – 1x10 3,5 9,0 190 72 5525746 – 1x16 4,1 10,5 255 96 6525748 – 1x25 4,9 13,0 385 127 8025750 – 1x35 5,5 14,0 490 157 8525752 – 1x50 8,7 16,5 660 196 10025754 – 1x70 9,9 19,0 925 242 11525756 – 1x95 11,8 20,5 1175 293 12525758 – 1x120 12,3 22,5 1475 339 13525760 – 1x150 13,7 25,0 1780 389 15025762 – 1x185 15,1 28,0 2180 444 17025764 – 1x240 17,0 30,5 2820 522 18525766 – 1x300 18,7 34,0 3465 601 20525770 – 2x1,5 3,8 10,0 130 20 6025785 – 2x2,5 4,3 10,5 160 26 6525801 – 2x4 4,9 12,0 205 34 7525803 – 2x6 5,4 13,0 315 44 8025805 – 2x10 8,7 15,5 480 61 9525807 – 2x16 10,0 18,0 665 82 11025809 – 2x25 12,3 22,5 1030 108 13525811 – 2x35 14,0 25,0 1305 133 15025772 25773 3x1,5 4,1 10,0 155 16 6025786 25787 3x2,5 4,6 11,0 195 21 7025802 25880 3x4 5,2 12,5 260 28 7525804 25882 3x6 5,8 14,0 370 36 8525806 25884 3x10 9,3 16,5 570 50 10025808 25886 3x16 10,7 19,0 805 67 11525810 25888 3x25 13,2 24,0 1240 89 14525812 25890 3x35 15,1 27,0 1600 110 16525814 25892 3x50 17,5 31,5 2125 137 19025816 25894 3x70 20,1 36,0 2970 169 22025818 25896 3x95 22,7 40,0 3825 205 24025820 25897 3x120 35,0 45,0 4890 237 27025822 25898 3x150 39,1 50,0 5970 272 30025774 25775 4x1,5 4,5 11,0 180 16 7025788 25789 4x2,5 5,0 12,5 240 21 7525830 25831 4x4 5,8 13,5 315 28 8525832 25833 4x6 8,8 15,5 475 36 9525834 25835 4x10 10,3 18,0 695 50 11025836 25837 4x16 11,9 21,5 1020 67 13025838 25839 4x25 14,7 26,5 1540 89 16025840 25841 4x35 16,7 29,5 2030 110 18025842 25843 4x50 19,4 34,5 2675 137 21025844 25845 4x70 22,4 40,0 3750 169 24026005 26006 4x95 35,0 45,0 5050 205 27026007 26008 4x120 39,1 50,0 6220 237 30025776 25777 5x1,5 5,0 12,0 220 14 7525790 25791 5x2,5 5,6 13,5 285 18 8526011 26012 5x4 8,6 15,0 410 25 9026013 26014 5x6 9,7 17,0 565 30 10526015 26016 5x10 11,8 20,0 835 44 12026017 26018 5x16 13,2 23,0 1210 56 14025778 25779 7x1,5 5,4 13,0 265 12 8025792 25793 7x2,5 11,4 15,0 380 16 9026025 26026 10x1,5 9,6 16,5 390 11 10026033 26034 10x2,5 11,7 18,5 535 14 11525780 25846 12x1,5 9,9 17,0 440 10 10525794 25795 12x2,5 11,8 19,0 595 13 11526027 26028 14x1,5 10,5 18,0 490 10 11026035 26036 14x2,5 11,9 20,5 680 13 12526030 26029 16x1,5 11,8 19,0 550 9 11526037 26038 16x2,5 12,5 21,5 760 12 13025782 25781 19x1,5 11,8 19,5 610 9 12025796 25797 19x2,5 13,2 22,5 855 11 13525828 25829 24x1,5 13,9 23,5 780 8 14525798 25799 24x2,5 15,7 26,0 1080 10 16025783 25847 27x1,5 14,1 24,0 845 8 14525768 25769 27x2,5 16,1 27,0 1175 10 16525784 25848 37x1,5 16,0 26,5 1085 7 160

LKSM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

screenmm2

110

,6/1

kV

CA

BLES

8/2

01

0

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 12: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

120

,6/1

kV

CA

BLE

S8

/20

10

LKSM-HF FLEX Armoured power cablewith flexible conductor0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.

Note! This cable is not designed for movable or portable applications.Flexible conductor cables ease the installation in areas involvingtight bending radius or high vibration.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 5

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape

4. Armour- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

Page 13: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

130

,6/1

kV

CA

BLES

8/2

01

0

LKSM-HF FLEX 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

26 237 – 1x16 4,1 10,0 240 94 6026 238 – 1x25 4,9 13,5 360 123 8526 239 – 1x35 5,5 14,5 460 153 9026 240 – 1x50 8,7 16,5 620 196 10026 241 – 1x70 9,9 18,5 870 240 11526 242 – 1x95 11,8 21,0 1050 284 13026 243 – 1x120 12,3 24,0 1385 331 14526 244 – 1x150 13,7 27,0 1715 381 16526 245 – 1x185 15,1 29,5 1920 429 18026 246 – 1x240 17,0 33,0 2650 507 20026 247 – 1x300 18,7 35,0 3300 582 21026 254 – 2x16 10,0 17,5 575 80 10526 255 – 2x25 12,3 22,5 875 105 13526 256 – 2x35 14,0 25,0 1125 130 15026 271 26 272 3x16 10,7 19,5 720 66 12026 273 26 274 3x25 13,2 24,0 1100 86 14526 275 26 276 3x35 15,1 26,5 1455 107 16026 277 26 278 3x50 17,5 32,5 1670 137 19526 279 26 280 3x70 20,1 36,0 2610 168 22026 281 26 282 3x95 22,7 41,5 3200 199 25026 283 26 284 3x120 35,0 47,5 4170 232 28526 285 26 286 3x150 39,1 53,5 5310 267 32526 301 26 302 4x16 11,9 21,5 870 66 13026 303 26 304 4x25 14,7 26,5 1450 86 16026 305 26 306 4x35 16,7 30,0 1870 107 18026 307 26 308 4x50 19,4 35,0 2490 137 21026 309 26 310 4x70 22,4 40,5 3440 168 24526 311 26 312 4x95 35,0 47,5 4430 199 28526 313 26 314 4x120 39,1 52,5 5800 232 31526 331 26 332 5x16 13,2 23,5 1070 55 145

Cross-section of

screenmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16

Page 14: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor 1,5–10mm2 IEC 60228, class2- stranded copper conductor 16–150mm2 IEC 60228, class5

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- extruded filler

4. Armour- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath-black polyolefine plastic, SHF1 IEC 60092-359

Application: For fixed installation in most areas and on open deck in ships.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

140

,6/1

kV

CA

BLE

S8

/20

10

LKMSM-HF Armoured power cablewith extruded filler 0,6/1kV

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 15: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

27232 – 2x1,5 12,0 12,0 190 20 7027234 – 2x2,5 13,0 13,0 230 26 7527236 – 2x4 14,0 14,0 285 34 8027238 – 2x6 15,5 15,5 415 44 9027240 – 2x10 18,0 18,0 570 61 10527243 – 2x16 12,4 19,0 640 26 11027245 – 2x25 15,4 23,5 930 34 13527247 – 2x35 17,1 26,0 1240 44 15027249 – 2x50 20,3 30,5 1665 61 18027264 27266 3x1,5 12,5 12,5 220 16 7027268 27270 3x2,5 13,5 13,5 270 21 8027272 27274 3x4 15,0 15,0 365 28 8527276 27278 3x6 16,5 16,5 485 36 9527280 27282 3x10 19,0 19,0 675 50 11027285 27287 3x16 13,2 20,0 800 16 11527289 27291 3x25 16,5 25,0 1180 21 14527293 27295 3x35 18,2 27,5 1560 28 16027297 27299 3x50 21,9 32,0 2120 36 19027301 27303 3x70 25,5 37,5 2925 50 22027305 27307 3x95 40,6 43,0 3870 16 25527309 27311 3x120 44,8 48,0 4795 21 28527313 27315 3x150 51,1 54,5 6010 28 32027328 27330 4x1,5 13,5 13,5 255 16 7527332 27334 4x2,5 14,5 14,5 315 21 8527336 27338 4x4 16,0 16,0 425 28 9527340 27342 4x6 18,0 18,0 575 36 10527344 27346 4x10 20,5 20,5 820 50 12027349 27351 4x16 14,5 22,5 1000 36 13027353 27355 4x25 18,2 27,5 1465 50 16027357 27359 4x35 20,2 30,5 1940 14 18027361 27363 4x50 24,1 36,0 2685 18 21027365 27367 4x70 38,8 41,5 3760 19 24527369 27371 4x95 44,9 48,0 4885 20 28527373 27375 4x120 50,3 53,5 6100 21 31527392 27394 5x1,5 14,5 14,5 295 14 8027396 27398 5x2,5 16,0 16,0 390 18 90

150

,6/1

kV

CA

BLES

8/2

01

0

LKMSM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

screenmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 16: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

160

,6/1

kV

CA

BLE

S8

/20

10

LKSM-EMC

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.Design to meet requirements for improved EMC screening properties.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/mat 100MHz [20mΩ/m])

For details see general information section

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: See technical information section.Cable with yellow/green protective earth (PE)conductor on request

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor-stranded copper conductor 1,5-10mm

2IEC 60228, class 2

-stranded copper conductor 16-150mm2

IEC 60228, class 5

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape - copper tape, coverage 100%

4. Armour- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

Armoured power and control cablewith improved EMC screening0,6/1kV

Page 17: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

170

,6/1

kV

CA

BLES

8/2

01

0

LKSM-EMC 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approx-imateweightkg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

26 861 3x1,5 3,8 10,5 180 16 6526 863 3x2,5 4,3 11,5 220 21 7026 865 3x4 5,0 12,5 295 28 7526 867 3x6 5,6 14,0 375 36 8526 869 3x10 8,9 16,5 570 50 10026 872 3x16 10,9 19,5 775 66 12026 874 3x25 13,3 24,5 1175 86 15026 876 3x35 15,1 27,0 1540 107 16526 878 3x50 17,6 32,0 1875 137 19526 880 3x70 28,0 36,5 2785 168 22026 882 3x95 22,8 42,0 3350 199 25526 884 3x120 35,1 47,0 4305 232 28526 886 3x150 39,2 53,0 5465 267 32526 942 4x1,5 4,3 11,0 210 16 7026 944 4x2,5 4,8 12,5 270 21 7526 946 4x4 5,5 13,5 350 28 8526 948 4x6 8,6 15,5 510 36 9526 950 4x10 9,9 18,5 710 50 11526 952 4x16 12,0 22,0 960 66 13526 954 4x25 14,8 27,0 1515 86 16526 956 4x35 16,8 29,5 1945 107 18026 958 4x50 19,5 35,5 2600 137 21526 960 4x70 31,1 40,0 3585 168 24026 962 4x95 35,1 47,5 4515 199 28526 964 4x120 39,2 52,5 5855 232 315

Cross-section of

screenmm2

Page 18: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

181

,8/3

kV

CA

BLE

S8

/20

10

LKSM-VFD

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Application: For fixed installation in most areas and on open deck in ships.Design to meet requirements for Variable Frequency Drivers (VFD).Suitable for voltage peaks to 3kV.

Main characteristics

Rated voltage 1,8/3kV (3,6kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/mat 100MHz [20mΩ/m])

For details see general information section

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: See technical information section.Cable with yellow/green protective earth (PE)conductor on request

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 5

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape - copper tape, coverage 100%

4. Armour- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

Armoured power and control cablewith improved EMC screening1,8/3kV

Page 19: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

191

,8/3

kV

CA

BLES

8/2

01

0

LKSM-VFD 1,8/3kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approx-imateweightkg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

26 920 1x16 5,6 14,0 355 94 85 1)26 922 1x25 11,5 16,0 520 123 100 1)26 924 1x35 11,5 17,0 625 153 105 1)26 926 1x50 10,3 19,0 780 196 115 1)26 928 1x70 11,4 20,5 995 240 125 1)26 930 1x95 12,6 23,5 1260 284 145 1)26 932 1x120 13,6 25,5 1515 331 155 1)26 934 1x150 14,7 27,5 1830 381 165 1)26 936 1x185 15,8 29,5 2165 429 180 1)26 938 1x240 17,6 33,0 2820 507 200 1)26 940 1x300 19,2 35,0 3370 582 210 1)26 871 3x16 16,5 26,5 945 66 16026 873 3x25 17,0 29,5 1230 86 18026 875 3x35 18,7 32,5 1615 107 19526 877 3x50 25,6 36,5 2165 137 22026 879 3x70 35,4 41,0 2935 168 25026 881 3x95 35,7 46,5 3705 199 280 1)26 883 3x120 38,9 50,5 4540 232 305 1)26 885 3x150 42,1 55,0 5485 267 335 1)26 893 3x95+3x16 35,7 46,5 4425 199 280 2)26 895 3x120+3x25 38,9 50,5 5060 232 305 2)26 897 3x150+3x25 42,1 55,0 5985 267 335 2)

Cross-section of

armourmm2

Note

NOTE!

1) = Protective earth (PE) rules are not fulfilled.

(PE rules, for cables over 16mm2 the PE-conductor have to be half of main conductor

and min. 16mm2. This according to IEC 60092-352, Electrical installations

in ships –Choice and installation of electrical cables)

2 = Three additional protective earth (PE) conductors.

Protective earth (PE) rules are fulfilled.

Page 20: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

200

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKAM-HF Screened power and control cable0,6/1kV

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Screen- drain wire of tinned copper 1,0mm2 (in all sizes)

- aluminium polyester tape, IEC 60092-350 coverage 100%

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request

Application: For fixed installation in most areas and on open deck in ships, especially when lightweight cables are needed.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 21: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

210

,6/1

kV

CA

BLES

8/2

01

0

LKAM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

27 102 – 2x1,5 8,5 95 20 5527 104 – 2x2,5 9,5 130 26 6027 106 27 107 3x1,5 9,0 115 16 5527 108 27 109 3x2,5 10,5 160 21 6527 110 27 111 4x1,5 10,0 150 16 6027 112 27 113 4x2,5 11,0 195 21 7027 114 27 115 5x1,5 11,0 175 14 7027 116 27 117 5x2,5 12,5 240 18 7527 118 27 119 7x1,5 12,0 215 12 7527 120 27 121 7x2,5 13,5 300 16 8527 140 27 141 10x1,5 15,5 310 11 9527 142 27 143 10x2,5 17,0 425 14 10527 122 27 123 12x1,5 16,0 350 10 10027 124 27 125 12x2,5 17,5 485 13 11027 126 27 127 19x1,5 18,5 510 9 11527 128 27 129 19x2,5 20,5 720 11 12527 134 27 135 27x1,5 22,5 710 8 13527 138 27 139 27x2,5 25,5 1025 10 155

Normal G-type

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 22: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

220

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded flexible IEC 60228, copper conductor class 5

2. Insulation- HF90 plastic IEC 60092-351- standard colour black, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKEM-HF Switchboard wire0,6/1kV

Application: For fixed wiring in switchboards, control panels and other enclosures.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Cable type, cable size, voltage and manufacturer's name

Page 23: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

230

,6/1

kV

CA

BLES

8/2

01

0

LKEM-HF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

25 120 1x0,75 2,7 14 14 1525 121 1x1,0 2,8 17 17 1525 122 1x1,5 3,1 21 22 1525 124 1x2,5 3,6 32 29 1525 125 1x4 4,1 45 37 2025 126 1x6 4,7 63 49 2025 128 1x10 5,7 103 69 2525 130 1x16 6,7 154 91 3025 132 1x25 8,6 244 118 3525 134 1x35 9,7 334 148 4025 136 1x50 11,9 476 196 5025 138 1x70 13,7 671 238 5525 165 1x95 16,2 887 275 6525 166 1x120 18,2 1125 322 75

Page 24: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

240

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

LKM-FRHF

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Fire-resistant unarmoured powerand control cable 0,6/1kV

Page 25: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

250

,6/1

kV

CA

BLES

8/2

01

0

LKM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

28 132 – 2x1,5 9,5 100 20 6028 134 – 2x2,5 10,0 125 26 6528 136 – 2x4 12,0 165 34 7028 138 – 2x6 13,0 265 44 8028 140 – 2x10 15,0 380 61 9028 142 – 2x16 17,5 555 82 10528 162 28 163 3x1,5 10,0 125 16 6528 164 28 165 3x2,5 11,0 160 21 7028 166 28 167 3x4 11,5 220 28 7528 168 28 169 3x6 13,0 325 36 8528 170 28 171 3x10 16,0 490 50 10028 172 28 173 3x16 18,5 725 67 11528 174 28 175 3x25 21,5 1100 89 14028 176 28 177 3x35 24,5 1470 110 16028 178 28 179 3x50 29,0 1955 137 18028 180 28 181 3x70 33,0 2780 169 21028 202 28 203 3x95 37,5 3655 205 23528 182 28 183 4x1,5 11,0 150 16 7028 184 28 185 4x2,5 11,5 205 21 7528 186 28 187 4x4 13,5 280 28 8528 188 28 189 4x6 15,0 410 36 9528 190 28 191 4x10 17,0 605 50 11028 192 28 193 4x16 20,5 915 67 12528 194 28 195 4x25 24,0 1405 89 15528 196 28 197 4x35 27,5 1875 110 17528 198 28 199 4x50 31,5 2510 137 20528 212 28 213 5x1,5 11,5 190 14 7528 214 28 215 5x2,5 13,0 251 18 8528 216 28 217 7x1,5 13,0 235 12 8028 218 28 219 7x2,5 14,5 315 16 9028 220 28 221 12x1,5 16,5 380 10 10528 222 28 223 12x2,5 18,5 525 13 12028 224 28 225 19x1,5 19,5 580 9 13028 226 28 227 19x2,5 22,0 795 11 14028 232 28 233 27x1,5 24,0 800 8 15528 234 28 235 37x1,5 27,0 1055 7 170

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 26: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

260

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

LKSM-FRHF

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Fire-resistant armoured powerand control cable 0,6/1kV

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic EC 60092-351

3. Bedding- separator tape

4. Armour- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Page 27: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

28 576 – 1x10 3,4 10 195 72 6028 578 – 1x16 3,9 11,0 270 96 7028 580 – 1x25 4,7 13,0 390 127 8028 582 – 1x35 5,4 14,0 495 157 8528 584 – 1x50 8,6 16,5 670 196 10028 586 – 1x70 9,8 18,5 915 242 11528 588 – 1x95 11,0 20,5 1180 293 12528 590 – 1x120 12,2 22,5 1465 339 13528 592 – 1x150 13,5 25,0 1770 389 15028 594 – 1x185 14,9 28,0 2190 444 17028 596 – 1x240 16,8 30,5 2820 522 18528 598 – 1x300 18,5 34,0 3475 601 20528 602 – 2x1,5 4,0 11,0 145 20 7028 604 – 2x2,5 4,4 11,5 175 26 7028 606 – 2x4 5,0 13,0 225 34 8028 608 – 2x6 5,6 14,0 340 44 8528 610 – 2x10 8,8 16,5 505 61 10028 612 – 2x16 10,2 19,0 700 82 11528 622 28 623 3x1,5 4,3 11,0 170 16 7028 624 28 625 3x2,5 4,8 12,5 215 21 7528 626 28 627 3x4 5,3 13,5 275 28 8528 628 28 629 3x6 8,6 15,0 430 36 9028 630 28 631 3x10 9,5 17,5 595 50 10528 632 28 633 3x16 11,0 20,0 845 67 12028 634 28 635 3x25 13,9 25,0 1285 89 15028 636 28 637 3x35 15,7 28,0 1655 110 17028 638 28 639 3x50 18,1 32,0 2175 137 19528 640 28 641 3x70 20,9 37,0 3005 169 22528 691 28 692 3x95 32,2 42,0 4010 205 25528 693 – 3x120 35,9 46,0 4925 237 28028 642 28 643 4x1,5 4,7 12,5 210 16 7528 644 28 645 4x2,5 5,3 13,5 260 21 8528 646 28 647 4x4 8,6 15,5 370 28 9528 648 28 649 4x6 9,1 16,5 505 36 10028 650 28 651 4x10 10,6 19,5 720 50 12028 652 28 653 4x16 12,2 22,5 1050 67 13528 654 28 655 4x25 15,5 27,5 1570 89 16528 656 28 657 4x35 17,5 30,5 2035 110 18528 658 28 659 4x50 20,2 35,5 2700 137 21528 662 28 663 5x1,5 5,2 13,5 245 14 8528 664 28 665 5x2,5 5,8 14,5 310 18 9028 666 28 667 7x1,5 5,8 14,5 295 12 9028 668 28 669 7x2,5 8,8 16,5 415 16 10028 670 28 671 12x1,5 10,7 19,0 495 10 11528 672 28 673 12x2,5 12,0 21,5 665 13 13028 674 28 675 19x1,5 12,8 22,5 705 9 13528 676 28 677 19x2,5 14,4 25,0 950 11 15028 682 28 683 27x1,5 15,6 27,0 965 8 16528 686 28 687 27x2,5 17,5 30,0 1325 10 18028 684 28 685 37x1,5 17,7 30,0 1260 7 180

270

,6/1

kV

CA

BLES

8/2

01

0

LKSM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

Cross-section of

screenmm2

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 28: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

280

,6/1

kV

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKAM-FRHF Fire-resistant screened powerand control cable 0,6/1kV

DESIGN: STANDARDS:IEC 60092-353, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape IEC 60092-351- XLPE plastic

3. Screen- drain wire of tinned copper 1,0mm2 (in all sizes)

- aluminium polyester tape, IEC 60092-350 coverage 100%

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Application: For fixed installation in most areas and on open deck in ships,especially when lightweight cables are needed.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: see technical information section

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 29: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

290

,6/1

kV

CA

BLES

8/2

01

0

LKAM-FRHF 0,6/1kV

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mmNormal G-type

28 741 – 2x1,5 10,0 115 20 6028 742 – 2x2,5 10,5 140 26 7028 743 28 744 3x1,5 10,5 140 16 6528 745 28 746 3x2,5 11,5 175 21 7028 747 28 748 4x1,5 11,0 165 16 7028 749 28 750 4x2,5 12,5 220 21 7528 751 28 752 5x1,5 12,5 205 14 7528 753 28 754 5x2,5 13,5 270 18 8528 755 – 7x1,5 13,5 250 12 8528 757 – 7x2,5 14,5 335 16 9028 759 – 10x1,5 17,0 350 11 10528 761 – 10x2,5 19,0 480 14 12028 763 – 12x1,5 17,5 400 10 11028 765 – 12x2,5 19,5 550 13 12028 775 – 19x1,5 20,5 580 9 13028 777 – 19x2,5 23,5 820 11 14528 783 – 27x1,5 25,5 825 8 15528 785 – 27x2,5 28,5 1155 10 175

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5

Page 30: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

302

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

LKM-HF Unarmoured control andinstrumentation cable250V

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended..

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 31: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

26365 2x0,75 6,5 50 11,3 25

26366 3x0,75 7,0 60 9,8 30

26367 4x0,75 7,5 75 8,9 30

26368 5x0,75 8,0 85 8,3 30

26369 7x0,75 8,5 110 7,4 35

26370 10x0,75 11,0 160 6,6 45

26371 12x0,75 11,5 180 6,2 45

26372 14x0,75 12,0 200 5,9 50

26373 16x0,75 13,0 235 5,6 50

26374 19x0,75 13,5 265 5,3 55

26376 24x0,75 16,0 335 4,9 65

26377 27x0,75 16,5 365 4,7 65

26378 32x0,75 17,0 415 4,5 65

26379 37x0,75 18,0 470 4,3 70

312

50

V C

AB

LES8

/20

10

LKM-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

Other sizes on request.

Page 32: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

322

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

LKSM-HF Armoured control andinstrumentation cable250V

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Armour- drain wire copper (in all sizes)- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Page 33: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

332

50

V C

AB

LES8

/20

10

LKSM-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

26402 2x0,75 3,6 7,5 90 11,3 4526403 3x0,75 3,6 8,0 100 9,8 5026404 4x0,75 3,6 8,5 110 8,9 5026405 5x0,75 4,1 9,5 140 8,3 5526407 7x0,75 4,1 10,0 160 7,4 6026410 10x0,75 5,1 12,5 220 6,6 7026412 12x0,75 5,3 13,0 240 6,2 7526414 14x0,75 5,6 13,5 265 5,9 7526416 16x0,75 6,1 14,0 295 5,6 8026419 19x0,75 8,7 14,5 330 5,3 8526424 24x0,75 11,7 17,5 450 4,9 10026427 27x0,75 11,7 17,5 480 4,7 10026432 32x0,75 11,8 18,5 540 4,5 10526437 37x0,75 11,9 19,5 600 4,3 115

Cross-section of

screenmm2

Other sizes on request.

Page 34: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

342

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Screen- drain wire of tinned copper- aluminium polyester tape, coverage 100% IEC 60092-350

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships, especially when lightweight cables are needed.

If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

LKAM-HF Screened instrumentation andcommunication cable 250V

Page 35: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

352

50

V C

AB

LES8

/20

10

26382 2x0,75 6,5 50 11,3 25

26383 3x0,75 7,0 60 9,8 30

26384 4x0,75 7,5 75 8,9 30

26385 5x0,75 8,0 85 8,3 30

26386 7x0,75 8,5 110 7,4 35

26387 10x0,75 11,0 160 6,6 45

26388 12x0,75 11,5 180 6,2 45

26389 14x0,75 12,0 200 5,9 50

26390 16x0,75 13,0 235 5,6 50

26391 19x0,75 13,5 265 5,3 55

26393 24x0,75 16,0 335 4,9 65

26394 27x0,75 16,5 365 4,7 65

26395 32x0,75 17,0 415 4,5 65

26396 37x0,75 18,0 470 4,3 70

LKAM-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

Other sizes on request.

Page 36: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

362

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Bedding- filler tape

4. Armour- drain wire copper (in all sizes)

- copper wire braid, coverage > 94% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Armoured instrumentation andcommunication cable 250VRFE-HF

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data:

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,5mm2 0,75mm2 1,5mm2 Unit

80 52 24,4 ohm/km

55 50 60 nF/km

0,6 0,6 0,7 mH/km

≥1500 ≥1500 ≥1500 Mohm*km.

Page 37: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

372

50

V C

AB

LES8

/20

10

RFE-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20 362 1x2x0,5 7,5 85 4520 364 2x2x0,5 Quad 8,0 100 5020 366 4x2x0,5 11,5 170 7020 368 7x2x0,5 14,0 245 8520 369 8x2x0,5 14,5 270 9020 370 10x2x0,5 17,0 350 10520 371 12x2x0,5 17,5 390 10520 372 14x2x0,5 18,5 440 11520 374 19x2x0,5 21,0 545 13020 376 24x2x0,5 23,5 665 14520 378 37x2x0,5 28,0 930 17020 382 1x2x0,75 7,5 95 4520 384 2x2x0,75 Quad 9,0 125 5520 386 4x2x0,75 12,5 215 7520 388 7x2x0,75 15,5 330 9520 389 8x2x0,75 16,0 375 10020 390 10x2x0,75 18,5 440 11520 391 12x2x0,75 19,0 490 11520 392 14x2x0,75 20,5 565 12520 394 19x2x0,75 23,5 715 14520 396 24x2x0,75 26,0 860 16020 490 1x2x1,5 10,0 140 6020 491 2x2x1,5 Quad 11,0 190 7020 493 4x2x1,5 17,0 375 10520 494 7x2x1,5 20,0 545 12020 495 8x2x1,5 21,5 625 13020 496 10x2x1,5 24,5 760 15020 497 12x2x1,5 25,5 855 15520 498 14x2x1,5 27,0 960 16520 499 19x2x1,5 31,0 1230 190

Twisted two pair cableon request:20 363 2x2x0,5 10,5 130 6520 383 2x2x0,75 11,0 155 7020 492 2x2x1,5 14,5 235 90

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

Page 38: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

382

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Pair screen- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- filler tape

5. Armour- drain wire copper (in all sizes)

- copper wire braid, coverage > 94% IEC 60092-350

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Armoured and pair screenedinstrumentation andcommunication cable 250V

RFE-HF (i)

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data:Loop resistance of pair, max. / +20°CPair capacitance, nom. / 800HzLoop inductance, nom.Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,75mm2 1,5mm2 Unit

52 24,4 ohm/km

70 90 nF/km

0,6 0,7 mH/km

≥1500 ≥1500 Mohm*km.

Page 39: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

392

50

V C

AB

LES8

/20

10

RFE-HF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

22 006 1x2x0,75 8,0 95 5022 010 2x2x0,75 11,5 170 7022 012 4x2x0,75 13,0 240 7522 014 7x2x0,75 15,5 375 10022 016 8x2x0,75 16,5 420 10522 018 10x2x0,75 19,0 520 11522 020 12x2x0,75 20,0 585 12022 022 14x2x0,75 21,0 650 13022 024 19x2x0,75 24,0 835 14522 026 24x2x0,75 27,0 1035 16022 050 1x2x1,5 10,0 150 6022 054 2x2x1,5 14,5 255 8522 056 4x2x1,5 17,0 415 10522 058 7x2x1,5 20,0 610 12522 060 8x2x1,5 22,0 700 13022 062 10x2x1,5 25,0 855 15022 064 12x2x1,5 26,0 965 15522 066 14x2x1,5 28,0 1105 16522 068 19x2x1,5 32,0 1440 190

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

Page 40: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

402

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Separator- separator tape

4. Screen- drain wire tinned copper- aluminium polyestercopper tape IEC 60092-350 coverage 100%

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Screened instrumentationand communication cable 250VRFA-HF

Application: For fixed installation in most areas and on open deck in ships, especiallywhen lightweight cables are needed. If the cable is exposed to directsun light protective covering or cable with black outer sheath isrecommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,5mm2 0,75mm2 Unit

80 52 ohm/km

55 50 nF/km

0,6 0,6 mH/km

≥1500 ≥1500 Mohm*km.

Page 41: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

412

50

V C

AB

LES8

/20

10

RFA-HF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20 910 1x2x0,5 6,0 45 4020 912 2x2x0,5 Quad 7,0 65 4520 916 4x2x0,5 10,5 120 6520 918 7x2x0,5 12,5 175 7520 920 8x2x0,5 13,5 200 8520 922 10x2x0,5 15,5 245 9520 924 12x2x0,5 16,0 280 10020 926 14x2x0,5 17,5 315 10520 930 19x2x0,5 20,0 410 12020 932 24x2x0,5 22,0 515 13520 936 37x2x0,5 27,0 745 16520 970 1x2x0,75 6,5 55 4020 972 2x2x0,75 Quad 7,5 80 4520 976 4x2x0,75 11,5 150 7020 978 7x2x0,75 14,0 225 8520 980 8x2x0,75 15,0 260 9020 982 10x2x0,75 17,0 320 10520 984 12x2x0,75 18,0 365 11020 986 14x2x0,75 19,0 415 11520 990 19x2x0,75 22,0 555 13520 992 24x2x0,75 24,5 680 150

Twisted pair cableson request. 20 914 2x2x0,5 9,0 75 5520 974 2x2x0,75 10,0 100 60

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

Page 42: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

Application: For fixed installation in most areas and on open deck in ships, especiallywhen lightweight cables are needed. If the cable is exposed to directsun light protective covering or cable with black outer sheath isrecommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom.

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

422

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

RFA-HF (i) Collectively and pair screenedinstrumentation andcommunication cable 250V

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- XLPE plastic IEC 60092-351

3. Pair screen- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- separator tape

5. Collective screen- drain wire tinned copper IEC 60092-350- aluminium polyester tape, coverage 100%

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request

0,5mm2 0,75mm2 Unit

80 52 ohm/km

55 70 nF/km

0,6 0,6 mH/km

≥1500 ≥1500 Mohm*km

Page 43: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

432

50

V C

AB

LES8

/20

10

Other sizes on request.

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are covered by a numbered tape (1, 2, 3, 4, 5....)

RFA-HF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20 940 2x2x0,5 9,5 95 6020 942 4x2x0,5 11,0 145 6520 944 7x2x0,5 13,0 220 8020 946 8x2x0,5 14,0 245 8520 948 10x2x0,5 16,0 305 9520 950 12x2x0,5 16,5 350 10020 952 14x2x0,5 17,5 395 11020 956 19x2x0,5 20,0 520 12520 958 24x2x0,5 22,5 655 14021 059 2x2x0,75 10,0 115 6521 061 4x2x0,75 12,0 180 7521 063 7x2x0,75 14,5 275 9021 065 8x2x0,75 15,0 310 9521 067 10x2x0,75 17,5 380 10521 069 12x2x0,75 18,0 440 11021 071 14x2x0,75 19,5 520 12021 075 19x2x0,75 22,5 680 13521 077 24x2x0,75 25,0 840 155

Page 44: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

442

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

LKM-FRHF Fire-resistant unarmouredinstrumentation andcommunication cable 250V

Page 45: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

22406 2x0,75 8,5 65 11,3 35

22407 3x0,75 9,0 80 9,8 35

22408 4x0,75 10,0 110 8,9 40

22409 5x0,75 11,0 130 8,3 45

22410 7x0,75 11,5 160 7,4 45

22411 10x0,75 15,0 225 6,6 60

22412 12x0,75 15,5 255 6,2 60

22413 14x0,75 16,5 295 5,9 65

22414 16x0,75 17,5 330 5,6 70

22415 19x0,75 18,0 375 5,3 75

22417 24x0,75 21,5 475 4,9 85

22418 27x0,75 22,0 520 4,7 85

22419 32x0,75 23,0 615 4,5 90

22420 37x0,75 25,0 695 4,3 100

Other size on request.

452

50

V C

AB

LES8

/20

10

LKM-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

Page 46: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

462

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

LKSM-FRHF

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Fire-resistant armouredinstrumentation andcommunication cable 250V

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic EC 60092-351

3. Bedding- separator tape

4. Armour- drain wire copper (in all sizes)

- copper wire braid, coverage > 90% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Page 47: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

472

50

V C

AB

LES8

/20

10

22436 2x0,75 3,6 9,0 105 11,3 55

22437 3x0,75 3,9 10,0 135 9,8 60

22438 4x0,75 4,4 11,0 160 8,9 65

22439 5x0,75 4,9 11,5 185 8,3 70

22440 7x0,75 5,4 12,5 220 7,4 75

22441 10x0,75 11,6 16,0 350 6,6 95

22442 12x0,75 11,6 16,5 380 6,2 100

22443 14x0,75 11,7 17,5 415 5,9 105

22444 16x0,75 11,3 18,5 445 5,6 110

22445 19x0,75 11,9 19,5 505 5,3 115

22447 24x0,75 14,3 23,0 640 4,9 135

22448 27x0,75 14,6 23,5 685 4,7 140

22449 32x0,75 15,3 24,0 765 4,5 145

22450 37x0,75 16,7 26,0 870 4,3 155

Other size on request.

LKSM-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

Cross-section of

screenmm2

Page 48: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

482

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LKAM-FRHF Fire-resistant screened controland instrumentation cable 250V

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape IEC 60092-351- XLPE plastic

3. Screen- drain wire of tinned copper- aluminium polyester tape, IEC 60092-350 coverage 100%

4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Application: For fixed installation in most areas and on open deck in ships,especially when lightweight cables are needed.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21 series

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Core identification: black numbers on white base

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Page 49: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

492

50

V C

AB

LES8

/20

10

LKAM-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Currentrating A

Min. bendingradius fixedinstallation

mm

22466 2x0,75 8,5 70 11,3 50

22467 3x0,75 9,0 85 9,8 55

22468 4x0,75 10,0 115 8,9 60

22469 5x0,75 11,0 135 8,3 65

22470 7x0,75 11,5 165 7,4 70

22471 10x0,75 15,0 230 6,6 90

22472 12x0,75 15,5 260 6,2 95

22473 14x0,75 16,5 300 5,9 100

22474 16x0,75 17,5 340 5,6 105

22475 19x0,75 18,0 380 5,3 110

22477 24x0,75 21,5 480 4,9 130

22478 27x0,75 22,0 525 4,7 130

22479 32x0,75 23,0 620 4,5 140

22480 37x0,75 25,0 700 4,3 150

Other size on request.

Page 50: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

502

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Bedding- filler tape

4. Armour- drain wire (in all sizes)

- copper wire braid, coverage > 94% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant armouredinstrumentation andcommunication cable 250V

RFE-FRHF

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,75mm2 1,5mm2 Unit

52 24,4 ohm/km

45 55 nF/km

0,6 0,7 mH/km

≥1500 ≥1500 Mohm*km.

Page 51: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

512

50

V C

AB

LES8

/20

10

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

RFE-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20 520 1x2x0,75 9,5 115 6020 522 2x2x0,75 Quad 11,0 160 7020 526 4x2x0,75 16,5 325 10020 528 7x2x0,75 20,0 465 12020 530 8x2x0,75 21,0 510 13020 532 10x2x0,75 24,5 630 15020 534 12x2x0,75 25,5 705 15520 536 14x2x0,75 27,0 800 16520 538 19x2x0,75 31,0 1015 19020 540 24x2x0,75 34,5 1245 21020 575 1x2x1,5 10,5 155 6520 577 2x2x1,5 Quad 12,0 220 7520 581 4x2x1,5 18,5 430 11520 583 7x2x1,5 22,5 650 14020 585 8x2x1,5 24,0 715 15020 587 10x2x1,5 27,5 875 16520 589 12x2x1,5 29,0 1000 17520 591 14x2x1,5 30,5 1125 185

Twisted two pair cableon request20 524 2x2x0,75 14,0 210 8520 579 2x2x1,5 16,0 315 100

Page 52: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

522

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Pair screen- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- filler tape

5. Armour- drain wire copper- copper wire braid, coverage > 94% IEC 60092-350

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant armoured andpair screened instrumentationand communication cable 250V

RFE-FRHF (i)

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

0,75mm2 1,5mm2 Unit

52 24,4 ohm/km

55 75 nF/km

0,6 0,7 mH/km

≥1500 ≥1500 Mohm*km.

Page 53: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

532

50

V C

AB

LES8

/20

10

RFE-FRHF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20 546 1x2x0,75 9,5 125 6020 550 2x2x0,75 14,5 225 9020 552 4x2x0,75 17,0 355 10520 554 7x2x0,75 20,0 515 12520 556 8x2x0,75 22,0 585 13520 558 10x2x0,75 25,0 710 15020 560 12x2x0,75 26,0 800 15520 562 14x2x0,75 27,5 910 17020 564 19x2x0,75 32,0 1175 19520 566 24x2x0,75 35,0 1425 21520 603 1x2x1,5 10,5 165 6520 605 2x2x1,5 16,5 320 10020 607 4x2x1,5 19,0 475 11520 609 7x2x1,5 23,0 720 14020 611 8x2x1,5 24,5 810 15020 613 10x2x1,5 28,0 985 17020 615 12x2x1,5 29,5 1145 18020 617 14x2x1,5 31,5 1295 190

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

Page 54: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

542

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Bedding- separator tape

4. Screen- drain wire tinned copper- aluminium polyester tape coverage 100% IEC 60092-350

5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant screenedinstrumentation andcommunication cable 250V

RFA-FRHF

0,75mm2 Unit

52 ohm/km

45 nF/km

0,6 mH/km

≥1500 Mohm*km.

Page 55: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

552

50

V C

AB

LES8

/20

10

RFA-FRHF 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20 635 1x2x0,75 8,5 75 5520 637 2x2x0,75 Quad 10,0 120 6020 641 4x2x0,75 15,5 215 9520 643 7x2x0,75 18,5 330 11520 645 8x2x0,75 20,0 380 12020 647 10x2x0,75 23,0 480 14020 649 12x2x0,75 24,0 545 14520 651 14x2x0,75 25,5 620 15520 655 19x2x0,75 29,5 805 18020 657 24x2x0,75 33,5 1030 205

Twisted two pair cableson request20 639 2x2x0,75 13,0 135 80

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

(Quad)cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue

Page 56: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

562

50

V C

AB

LES

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Application: For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 150/250V (300V)

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Fire-resistant IEC 60331-21

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Electrical data

Loop resistance of pair, max. / +20°C

Pair capacitance, nom. / 800Hz

Loop inductance, nom.

Insulation resistance / +20°C

Minimum recommended installation temperature -15 °CLowest operation temperature -40 °C

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

DESIGN: STANDARDS:IEC 60092-376, design

1. Conductor- stranded copper conductor IEC 60228, class 2

2. Insulation- Mica tape- XLPE plastic IEC 60092-351

3. Pair screen- plastic coated aluminium tape and a tinned copper drain wire

4. Bedding- separator tape

5. Collective screen- drain wire tinned copper- aluminium polyester tape coverage 100 % IEC 60092-350

6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour orange, other colours on request

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Fire-resistant collectively andpair screened instrumentationand communication cable 250V

RFA-FRHF (i)

0,75mm2 Unit

52 ohm/km

55 nF/km

0,6 mH/km

≥1500 Mohm*km.

Page 57: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

572

50

V C

AB

LES8

/20

10

Core identification

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....

The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

RFA-FRHF(i) 250V

Part number

Number ofconductors &cross-section

n x mm2

Nominalouter

diametermm

Approximateweight kg/km

Min. bendingradius fixedinstallation

mm

20 667 2x2x0,75 13,5 155 8520 669 4x2x0,75 15,5 245 9520 671 7x2x0,75 18,5 380 11520 673 8x2x0,75 20,0 430 12020 675 10x2x0,75 23,5 545 14520 677 12x2x0,75 24,5 625 15020 679 14x2x0,75 26,0 725 16020 683 19x2x0,75 30,0 945 18020 685 24x2x0,75 34,0 1205 205

Page 58: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

586

0V

CA

BLE

S

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

PBS Field bus cable60V

Application: For fixed installation in most areas.If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended.

Main characteristics

Rated voltage 60V

Maximum conductortemperature + 90 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath

Core identification

Each pair green - red.

DESIGN: STANDARDS:Twisted pair cable EN 50170

1. Conductor- stranded copper conductor

2. Insulation- Polyethylene / foamed polyethylene plastic

3. Pair twisting

4. Bedding- separator tape

5. Screen- plastic coated aluminium tape and tinned copper braid, coverage 100%

6. Sheath- purple, polyolefine plastic

7. Outer sheath - grey polyolefine plastic, SHF1

Page 59: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

596

0V

CA

BLES

8/2

01

0

PBS

Number of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm

20 506 1 x 2 x 0,34 10,5 145 65

Cable for PROFIBUS DP.

The cable has been tested according to the IEC 61158 specification

and testing guidelines set by PROFIBUS Center Nederland.

Cable is approved as type A cable.

Compatible with the connector of Siemens (6ES7-972-0BA12 0XA0 or similar)

after stripping the outer sheath.

Type A bus cable. Maximum length of each bus segment.

Data transfer rate in kbit/s 9.6 – 93.75 187.5 500 1500 3000 – 12000

Max. segment length in m 1200 1000 400 200 100

Part number

Page 60: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

60O

PTI

CA

L FI

BR

E CA

BLE

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Cable construction: (for example FXMSU 2x6 SML + 3x4 GKL)

1. Central element glass fibre, 1,5 mm

2. PP-slotted core, 6,0 mm

3. Optical fibres, 250 μm

4. Swellable tape

5. Rip cord

6. UV-protected and halogen free sheath

FXMSU Optical fibreindoor/outdoor cable

- non-metallic

- networks in marine applications

- Fibres: 250 μm SM or MM fibres

- 4 - 48 fibres

Cable characteristics: (for example FXMSU 2x6 SML + 3x4 GKL)

Maximum pulling force 500 N EN 187000 method 501

Crush strength / 100 mm (plate) 4000 N EN 187000 method 504

Crush strength / 25 mm (mandrel) 650 N EN 187000 method 504

Impact strength 30 J EN 187000 method 505

Sheath marking Cable type, manufacturer, man. no.,man. time, length marking in m.

Minimum bending radius 140 mm during installation,100 mm in final bending

Nominal cable diameter 9.4 mm

Cable weight 75 kg/km

Minimum installation temperature -15 °C

Operating temperature range -45...+70 °C

Longitudinal water tightness EN 187000 method 605B

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and cables,

category A

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

✳. Slotted corecables haveblue and redmarker threadsfor the first andlast slotrespectively.

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Page 61: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

61O

PTIC

AL FIB

RE C

AB

LE8

/20

10

Cable construction: (for example FXMMS 8 GKT)

1. FRP central element 2 mm

2. PP-slotted core 9,7 mm

3. Installation cable unit FMS 1 (2 mm)

4. Fire barrier tape

5. Rip cord

6. Halogen free sheath 1,5 mm

FXMMS Optical fibreinstallation cable

- For tray installation- Fibres: 2–8 SM or MM fibres, 900 μm- Connectors can be mounted directly to the fibres

Cable characteristics: (for example FXMMS 8 SMT)

Maximum pulling force 1500 N EN 187000 method 501Crush strength / 100 mm (plate) 4000 N EN 187000 method 504Crush strength / 25 mm (mandrel) 750 N EN 187000 method 504Impact strength, R = 300 mm 30 J EN 187000 method 505Sheath marking Cable type, manufacturer, man. no.,

man. time, length marking in m.Minimum bending radius 195 mm during installation, 130 mm in final bendingNominal cable diameter 13.1 mmCable weight 142 kg/kmMinimum installation temperature -15 °COperating temperature range -45...+70 °C

Flame-retardant IEC 60332-1-2 -test for single insulated wire and cableIEC 60332-3-24 -test for bunched wires and cables,

category C

Halogen-free IEC 60754 series

Smoke emission IEC 61034 series

For details see general information section

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

Page 62: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

62O

PTI

CA

L FI

BR

E CA

BLE

Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi

8/2

01

0

Flame-retardant

Fire-resistant

Halogen-free

Lowsmokeemission

LifeCord-FRHF Optical fibreinstallation cable

Application: Indoor cable for building cabling in places wherethe cable has to maintain its functionality during fire.

Main characteristicsMaximum pulling force 2500 N EN 187000 method 501Crush strength / 100 mm (plate) 7000 N EN 187000 method 504Crush strength / 25 mm (mandrel) 1500 N EN 187000 method 504Impact strength 50 J EN 187000 method 505Minimum bending radius 270 mm during installation,

200 mm in fixed installationNominal cable diameter 13.5 mmCable weight 196 kg/kmMinimum installation temperature -15 °COperating temperature range -30...+70 °C

Fire propertiesFire-resistant IEC 60331-21 -min. 90 min/750 °CFlame-retardant IEC 60332-1-2 -test for single insulated wire and cable

IEC 60332-3-22 -test for bunched wires and cables, category A

Halogen-free IEC 60754 seriesSmoke emission IEC 61034 series

Identification: Lot number, cable type, cable size, standards, production month,manufacturer's name and meter marking printed on the sheath

Standard cable types:

DESIGN:

1. Central element - glass fibre, 3,3 mm

2. PP-slotted core - 8,0 mm

3. Optical fibres - 250 μm

4. Swellable and flame-retardant tape

5. Corrugated steel tape - 0,15 mm

6. Sheath - polyolefine plastic, halogen-free, UV-protected- standard colour red- other colours on request

Other cables on request

LifeCord FRHF 1x6 SML (OS1)LifeCord FRHF 2x6 SML (OS1)LifeCord FRHF 4x6 SML (OS1)

LifeCord FRHF 1x4 GKL (OM1)LifeCord FRHF 2x4 GKL (OM1)LifeCord FRHF 3x4 GKL (OM1)LifeCord FRHF 6x4 GKL (OM1)

LifeCord FRHF 1x4 OM3LifeCord FRHF 2x4 OM3LifeCord FRHF 3x4 OM3LifeCord FRHF 6x4 OM3

LifeCord FRHF 1x4 SML (OS1) + 2x4 GKL (OM1)LifeCord FRHF 1x6 SML (OS1) + 3x4 GKL (OM1)LifeCord FRHF 2x6 SML (OS1) + 3x4 GKL (OM1)

LifeCord FRHF 1x4 SML (OS1) + 2x4 OM3LifeCord FRHF 1x6 SML (OS1) + 3x4 OM3LifeCord FRHF 2x6 SML (OS1) + 3x4 OM3

Page 63: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

63O

PTIC

AL FIB

RE C

AB

LE8

/20

10

Cabled optical fibres characteristicsFibre coating: L = 250 μm ± 10 μm

T = 900 μm ± 50 μm

Single mode fibre 10/125 μm SM / OS2 (ITU-T G.652.D)

Mode field diameter (MFD) 1310 nm 9,3 +/- 0,5 μm

Mode field eccentricity ≤ 1,0 μm

-Installation cables ≤ 0,5 μm

Cladding diameter 125 +/- 2 μm

- Installation cables 125 +/- 1 μm

Cladding ellipticity ≤ 2 %

Fibre attenuation 1310 nm ≤ 0,40 dB/km

1550 nm ≤ 0,25 dB/km

Zero dispersion range 1300...1324 nm

Dispersion coefficient ≤ 0,093 ps/nm2/km

- Dispersion at 1550 nm ≤ 18 ps/nm/km

Cut-off wavelength ≤ 1260 nm

- Installation cables 1180...1250 nm

Polarization mode dispersion ≤ 0,5 ps/√km

Proof test 1 % / 1 sec

Fibre identification 6 colour systemaccording to SFS 5648

Multi mode fibre 50/125 μm OM3

Core diameter 50 +/- 3 μm

Core ellipticity ≤ 6 %

Core eccentricity ≤ 3 μm

Cladding diameter 125 +/- 2 μm

Cladding ellipticity ≤ 2 %

Fibre attenuation 850 nm ≤ 2,7 dB/km

1300 nm ≤ 0,8 dB/km

Bandwidth 850 nm ≥ 1500 MHz x km (LED)

1300 nm ≥ 500 MHz x km (LED)

850 nm ≥ 2000 MHz x km (Laser)

Numerical aperture, NA 0,200 +/- 0,015

Fibre identification 6 colour systemaccording to SFS 5648

Multi mode fibre 62,5/125 μm GK / OM1

Core diameter 62,5 +/- 3 μm

Core ellipticity ≤ 6 %

Core eccentricity ≤ 3 μm

Cladding diameter 125 +/- 2 μm

Cladding ellipticity ≤ 2 %

Fibre attenuation 850 nm ≤ 3,5 dB/km

1300 nm ≤ 1,0 dB/km

Bandwidth 850 nm ≥ 200 MHz x km

1300 nm ≥ 500 MHz x km

Numerical aperture, NA 0,275 +/- 0,015

Fibre identification 6 colour systemaccording to SFS 5648

Page 64: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

Amount of Category burning Burning time

material

A 7 litres/m 40 min

B 3,5 litres/m 40 min

C 1,5 litres/m 20 min

64TE

CHNI

CAL

INFO

RMAT

ION

8/2

01

0

All Helkama cables comply with the mostsevere requirements ofcategory A.

Test on

bunched

cables

IEC 60332-3

Burning isallowed upto max. 2.5meters fromthe burnerwithinspecified time.

IEC 60332-1 is the test for single insu-lated wire and cable. Test procedure andrequirements according to the picture,below.

Halogen-free

Halogen-free refers to the absenceof halogens, such as chlorine andfluorine, and is determined onthe basis of halogen content andthe acidity of gases of a cable.

IEC 60754-1 determines thehalogen content of the material.To meet the requirements ashalogen-free the halogen contentof the material may not exceed0,5 % or 5 mg/g.

IEC 60754-2 determines thedegree of acidity of gases evolvedduring combustion. The limitvalues are 4,3 for pH and10 mikroS for conductivity.

Smoke emission

Smoke emission refers to visibilityin a fire. The greater the light trans-mittance, the better the visibility.When tested in accordance withIEC 61034-1 (test method) andIEC 61034-2 (test requirements)the smoke emission of a cable duringfire must not exceed the following values.

Fire-resistant

To be classified as fire-resistant the cables must withstand the test specified in standardIEC 60331-21. The cables must operate for a minimum of 90 minutes while the burneris directed towards the cable as shown below. Helkama fire-resistant cables are also flame-retardant.

Requirements:60 % lighttransmittance

27m3 cubesmoke chamber

Min. 50 mm of the cable, measured fromthe upper support, must remain unburnedafter the specified time.

475 550 600mm mm mm

50 mm

750 °C / 90 min

gas burner610 mm

75 mm

Un

3A

3.5

m

1 m

4 m

2.5

m

2 m

Insulation material:

The following designations are used forinsulation materials in this catalog.All materials are halogen-free.

XLPE stands for cross-linked poly-ethylene compound. It has excellentmechanical and electrical characteristics.

Sheathing material:

The designation SHF1 stands forthermoplastic compound. This materialis halogen-free, highly flame-retardantand has low smoke emission.

Definition of terms:

Flame-retardant

To be flame-retardant, the cablesmust withstand the test specified inIEC standard 60332-3 or IEC 60332-1.Flame-retardant cables do not propagatefire, and are self-extinguishing.

IEC 60332-3 is the test for bunched wiresand cables and has three cate-gories A,B and C, defined by different limits forflammable material and burning times.Burning time describes how long theburner is directed towards the bunch ofcables. The requirement for passing thetest is that after the burner has beenremoved the cables must extinguishthemselves. Burning may not occur morethan 2.5 m from the burner as shown inthe figure.

GENERAL INFORMATION

Page 65: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

65TECHNICAL INFORM

ATION8

/20

10

BENDING RADIUS

Recommended minimum bending

radius, ( R ) :

Radius (R)

Outer

diameter (D)

LKM-HF During installation R = 6x D < 25mmLKMM-HF During installation R = 6x D < 25mmLKM-FRHF During installation R = 9x D > 25mmLKEM-HF Fixed instalation R = 4x D < 25mm

Fixed instalation R = 6x D > 25mm(Unarmoured or unscreened cables)

LKSM-HF During installation R = 9x DLKSM-EMC Fixed instalation R = 6x DLKSM-VFDLKMSM-HFLKAM-HFLKSM-FRHFLKAM-FRHFRFE-HFRFE-HF(i)RFA-HFRFA-HF(i)RFE-FRHFRFE-FRHF(i)RFA-FRHFRFA-FRHF(i)PBS(Armoured or screened cables)

250V

a bPairnumber1 1 22 3 43 5 64 7 85 9 106 11 12etc.

60V

(PBS)

DIAMETER TOLERANCE Cable outer diameter, mm. Tolerance1 – 10 ±0,5mm

10,1 – 20 ±1,0mm20,1 – 30 ±1,5mm

Cable outer diameter, mm. Tolerance30,1 – 40 ±2,0mm40,1 – 50 ±2,5mm50,1 – 60 ±3,0mm

CORE IDENTIFICATION

Black numberson white base

Black numberson white base

Last coreyellow/green.

6

71

23

45

12

34

5BU

BKBN

GY

Y/G

61

23

45

Y/G

BU

BN

Y/G

BK

BN BU

BKGY

BNBU

GY

BN BK

BN

GY

Y/G

BK

0,6/1kV Normal type G-typewith earthconductor)

1-core

2-cores

3-cores

4-cores

5-cores

7-coresand above

BU = Blue, BN = Brown, BK = Black, GY = Grey, Y/G = Yellow/Green

Page 66: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

66TE

CHNI

CAL

INFO

RMAT

ION

8/2

01

0

Ik = Maximum permissible short circuit current.S = Cross-section of the conductor in mm2.t = Duration of the short circuit in s.

Tk = Maximum rated conductor temperature,short circuit, °C

Tb = Maximum rated conductor temperature,normal, °C

Formula 1: For 0,6/1kV cable with XLPE or HF90 withmaximum operating temperature of +90°C (Tb) and short circuit temperature of +250°C (Tk).

Maximum permissible short circuit current.0,6/1 kV +90°C marine cables.

Formula 1:

S

tIk = 146 X

SHORT CIRCUIT CURRENT

Cross-section of Duration of the short circuit in s. the conductor in mm2 0,2 0,5 1 2 3 10

1,5 0,5 0,3 0,2 0,2 0,1 0,12,5 0,8 0,5 0,4 0,3 0,2 0,14 1,3 0,8 0,6 0,4 0,3 0,26 2,0 1,2 0,9 0,6 0,5 0,310 3,3 2,1 1,5 1,0 0,8 0,516 5,2 3,3 2,3 1,7 1,3 0,725 8,2 5,2 3,7 2,6 2,1 1,235 11,4 7,2 5,1 3,6 3,0 1,650 16,3 10,3 7,3 5,2 4,2 2,370 22,9 14,5 10,2 7,2 5,9 3,295 31,0 19,6 13,9 9,8 8,0 4,4120 39,2 24,8 17,5 12,4 10,1 5,5150 49,0 31,0 21,9 15,5 12,6 6,9185 60,4 38,2 27,0 19,1 15,6 8,5240 78,4 49,6 35,0 24,8 20,2 11,1300 97,9 61,9 43,8 31,0 25,3 13,9

Short circuit current in kA

Based on formula:

S 234 + Tk

t 234 + TbIk = 226 X X In

CURRENT RATING

"Current rating (A) at an ambient temperature of 45°Caccording to the standard IEC 60092-3520,6/1 kV +90°C marine cables."

Current carrying capacities in continous service atmaximum rated conductor temperature of +90°C.

For continuous service. Continuous service for a cable isto be considered as a current-carrying service (withconstant load) having a duration longer than three timesthe thermal time constant of the cable, i.e. longer thanthe critical duration(see short time duty).

Size 1 2 3 4 5 7 10 12 14 16 19 24 27 37

Factor, n 1 0,85 0,7 0,7 0,58 0,52 0,46 0,44 0,41 0,40 0,37 0,35 0,33 0,301,5 mm2 23 20 16 16 13 12 11 10 9 9 9 8 8 72,5 mm2 30 26 21 21 17 16 14 13 12 12 11 11 10 94 mm2 40 34 28 28 23 – – – – – – – – –6 mm2 52 44 36 36 30 – – – – – – – – –10 mm2 72 61 50 50 42 – – – – – – – – –16 mm2 96 82 67 67 56 – – – – – – – – –25 mm2 127 108 89 89 – – – – – – – – – –35 mm2 157 133 110 110 – – – – – – – – – –50 mm2 196 167 137 137 – – – – – – – – – –70 mm2 242 206 169 169 – – – – – – – – – –95 mm2 293 249 205 205 – – – – – – – – – –120 mm2 339 288 237 237 – – – – – – – – – –150 mm2 389 331 272 272 – – – – – – – – – –185 mm2 444 377 311 311 – – – – – – – – – –240 mm2 522 444 365 365 – – – – – – – – – –300 mm2 601 511 421 421 – – – – – – – – – –

N

For class 2 conductor cables

Size 1 2 3 4 5

Factor, n 1 0,85 0,7 0,7 0,5816mm2 94 80 66 66 5525mm2 123 105 86 86 –35mm2 153 130 107 107 –50mm2 196 167 137 137 –70mm2 240 204 168 168 –95mm2 284 241 199 199 –

N

For class 5 conductor cables

Size 1 2 3 4 5

Factor, n 1 0,85 0,7 0,7 0,58120mm2 331 281 232 232 –150mm2 381 324 267 267 –185mm2 429 365 300 300 –240mm2 507 431 355 355 –300mm2 582 495 407 407 –

N

For class 5 conductor cables

Page 67: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

67TECHNICAL INFORM

ATION8

/20

10

Intermittent service

Correction factor for intermittent serviceaccording to the standard IEC 60092-352

The correction factor given hereby has beenroughly calculated for periods of 10 min,of which 4 min are with a constant load and6 min without load.

Intermittence period = 10min.Intermittence ratio = 40%.

1-exp(-10/T)

1-exp(-4/T)

Fi=

SHORT TIME DUTY

T = 0,245 x d 1,35

(d = Overall diameter of the cable, mm.)

Short time duty according to the standardIEC 60092-352 0,6/1 kV +90°Cmarine cables.

If a cable is intended to supply motoror equipment operating for periods of half an hour orone hour, its current rating given in table “currentrating”, may be increased using the relevantcorrection factors given by formula:

1,12

1-exp(-ts/T)

=correction

factor

( ts = service time, min. T = Time constant, min.)

Overall diameter of Correction the cable, mm. factor.

1 1,0002 1,0013 1,0124 1,0425 1,0836 1,1277 1,1708 1,2089 1,24210 1,27320 1,43330 1,49040 1,51850 1,53460 1,544

Overall Service Time Criticaldiameter of time, min. constant, duration,the cable, min. min.

mm.

30 60 T 3x T

1 1,058 1,058 0,245 0,7352 1,058 1,058 0,625 1,873 1,058 1,058 1,08 3,244 1,058 1,058 1,59 4,785 1,058 1,058 2,15 6,466 1,058 1,058 2,75 8,267 1,058 1,058 3,39 10,28 1,059 1,058 4,06 12,29 1,059 1,058 4,76 14,310 1,061 1,058 5,48 16,520 1,126 1,066 14,0 41,930 1,255 1,105 24,2 72,540 1,403 1,173 35,6 10750 1,554 1,254 48,2 14560 1,705 1,341 61,6 185

Correction factor.

Page 68: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

SHORT CIRCUIT FACTORS

Short circuit factors for two (2) core cablesShort circuit factors for single (1) core cables

Cross-section of Duration of the short circuit in s. the conductor in mm2 0,2 0,5 1 2 3

1,5 23,3 14,7 10,4 7,4 6,02,5 27,2 17,2 12,2 8,6 7,04 32,6 20,6 14,6 10,3 8,46 38,4 24,3 17,2 12,1 9,9

10 46,0 29,1 20,6 14,5 11,916 55,0 34,8 24,6 17,4 14,225 65,3 41,3 29,2 20,6 16,935 73,7 46,6 33,0 23,3 19,050 85,9 54,3 38,4 27,2 22,270 95,2 60,2 42,6 30,1 24,695 106,9 67,6 47,8 33,8 27,6

120 115,2 72,9 51,5 36,4 29,8150 127,2 80,4 56,9 40,2 32,8185 137,3 86,8 61,4 43,4 35,4240 150,7 95,3 67,4 47,6 38,9300 166,0 105,0 74,2 52,5 42,9

Cross-section of Duration of the short circuit in s. the conductor in mm2 0,2 0,5 1 2 3

1,5 27,2 17,2 12,2 8,6 7,02,5 32,6 20,6 14,6 10,3 8,44 38,4 24,3 17,2 12,1 9,96 45,6 28,8 20,4 14,4 11,810 54,4 34,4 24,3 17,2 14,016 64,5 40,8 28,8 20,4 16,725 77,7 49,2 34,8 24,6 20,135 84,6 53,5 37,9 26,8 21,950 98,9 62,6 44,2 31,3 25,570 114,3 72,3 51,1 36,1 29,595 – – – – –120 – – – – –150 – – – – –185 – – – – –240 – – – – –300 – – – – –

Short circuit factors for cables with a core no.from five (5) to thirtyseven (37)

Short circuit factors for three (3) andfour (4) core cables

The conductor Duration of the short circuit in s. in mm2

0,2 0,5 1 2 3

5x1,5 35,0 22,1 15,6 11,1 9,05x2,5 45,3 28,7 20,3 14,3 11,75x4 52,2 33,0 23,4 16,5 13,55x6 65,3 41,3 29,2 20,6 16,95x10 74,2 46,9 33,2 23,5 19,25x16 93,3 59,0 41,7 29,5 24,17x1,5 40,8 25,8 18,3 12,9 10,57x2,5 51,0 32,3 22,8 16,1 13,210x1,5 44,5 28,2 19,9 14,1 11,510x2,5 58,3 36,9 26,1 18,4 15,112x1,5 49,0 31,0 21,9 15,5 12,612x2,5 62,8 39,7 28,1 19,9 16,214x1,5 49,0 31,0 21,9 15,5 12,614x2,5 62,8 39,7 28,1 19,9 16,216x1,5 54,4 34,4 24,3 17,2 14,016x2,5 68,0 43,0 30,4 21,5 17,619x1,5 54,4 34,4 24,3 17,2 14,019x2,5 74,2 46,9 33,2 23,5 19,224x1,5 61,2 38,7 27,4 19,4 15,824x2,5 81,6 51,6 36,5 25,8 21,127x1,5 61,2 38,7 27,4 19,4 15,827x2,5 81,6 51,6 36,5 25,8 21,137x1,5 70,0 44,2 31,3 22,1 18,137x2,5 90,7 57,4 40,6 28,7 23,4

The conductor Duration of the short circuit in s. in mm2

0,2 0,5 1 2 3

1,5 32,6 20,6 14,6 10,3 8,42,5 38,9 24,6 17,4 12,3 10,04 45,0 28,5 20,1 14,2 11,66 54,4 34,4 24,3 17,2 14,0

10 65,3 41,3 29,2 20,6 16,916 78,0 49,3 34,9 24,7 20,125 91,7 58,0 41,0 29,0 23,735 108,8 68,8 48,7 34,4 28,150 120,9 76,5 54,1 38,2 31,270 134,4 85,0 60,1 42,5 34,795 151,3 95,7 67,7 47,8 39,1

120 163,2 103,2 73,0 51,6 42,1150 181,4 114,7 81,1 57,4 46,8185 198,0 125,2 88,6 62,6 51,1240 214,7 135,8 96,0 67,9 55,4300 236,0 149,3 105,5 74,6 60,9

68TE

CHNI

CAL

INFO

RMAT

ION

8/2

01

0

Page 69: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

VOLTAGE DROP

Cable types: LKM-HF, LKSM-HF, LKAM-HF, LKM-FRHF, LKSM-FRHF (Cables with class 2 conductor)

Size Resistance Resistance Voltage Resistance Current Voltageat +20°C at +90°C reduction at +45°C rating reductionohm/km ohm/km mV/Am *) ohm/km A **) mV/m ***)

1,5 mm2 12,1 15,4 30,9 13,3 23 0,612,5 mm2 7,41 9,45 18,9 8,14 30 0,494 mm2 4,61 5,88 11,8 5,06 40 0,416 mm2 3,08 3,93 7,85 3,38 52 0,3510 mm2 1,83 2,33 4,67 2,01 72 0,2916 mm2 1,15 1,47 2,93 1,26 96 0,2425 mm2 0,727 0,927 1,85 0,798 127 0,2035 mm2 0,524 0,668 1,34 0,575 157 0,1850 mm2 0,387 0,493 0,99 0,425 196 0,1670 mm2 0,268 0,342 0,68 0,294 242 0,1495 mm2 0,193 0,246 0,49 0,212 293 0,12120 mm2 0,153 0,195 0,39 0,168 339 0,11150 mm2 0,124 0,158 0,32 0,136 389 0,10185 mm2 0,0991 0,1264 0,25 0,1088 444 0,096240 mm2 0,0754 0,0961 0,19 0,0828 522 0,086300 mm2 0,0601 0,0766 0,15 0,0660 601 0,078

Cable types: LKM-HF FLEX, LKSM-HF FLEX, LKEM-HF (Cables with class 5 conductor)

Size Resistance Resistance Voltage Resistance Current Voltageat +20°C at +90°C reduction at +45°C rating reductionohm/km ohm/km mV/Am *) ohm/km A **) mV/m ***)

0,75mm2 26,0 33,2 66,3 28,6 14 0,801,0mm2 19,5 24,9 49,7 21,4 17 0,731,5mm2 13,3 17,0 33,9 14,6 22 0,642,5mm2 7,98 10,18 20,4 8,76 30 0,534mm2 4,95 6,31 12,6 5,44 39 0,426mm2 3,30 4,21 8,42 3,62 50 0,3610mm2 1,91 2,44 4,87 2,10 71 0,3016mm2 1,21 1,54 3,09 1,33 94 0,2525mm2 0,780 0,995 1,99 0,857 123 0,2135mm2 0,554 0,706 1,41 0,608 153 0,1950mm2 0,386 0,492 0,98 0,424 196 0,1770mm2 0,272 0,347 0,69 0,299 240 0,1495mm2 0,206 0,263 0,53 0,226 284 0,13120mm2 0,161 0,205 0,41 0,177 331 0,12150mm2 0,129 0,164 0,33 0,142 389 0,11185mm2 0,106 0,135 0,27 0,116 444 0,10240mm2 0,0801 0,102 0,20 0,088 522 0,09300mm2 0,0641 0,082 0,16 0,070 601 0,08

Cable types: LKSM-HF 250V, RFE-HF, RFE-HF(i), RFA-HF, RFA-HF(i), RFE-FRHF, RFE-FRHF(i), RFA-FRHF, RFA-FRHF(i)

Size Resistance Maximum Resistance Voltage Resistance Voltageat +20°C conductor at +45°C reduction at +90°C reductionohm/km temperature, °C ohm/km mV/Am at +45°C ohm/km mV/Am at +90°C

0,5 mm2 40,4 90 44,4 88,7 51,5 103,00,75 mm2 26,0 90 28,6 57,1 33,2 66,31,5 mm2 12,8 90 14,1 28,1 16,3 32,6

*) at +90°C**) For continuous service (single core, ambient temperature +45°C)

***) at maximum current rating for continuous service at +45°C

69TECHNICAL INFORM

ATION8

/20

10

Page 70: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

70NO

TES

8/2

01

0

Page 71: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

71NOTES

8/2

01

0

Page 72: 8/2010 Marine Cables6 0,6/1kV CABLES 8/2010 DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 5 2. Insulation - XLPE plastic IEC 60092-351

HELKAMA BICA OY

Lakimiehenkatu 4FI-20780 KAARINAFinland

Tel. +358 2 410 8700Fax +358 2 410 8750

[email protected]

Helkama Bica (Shanghai) Co., Ltd.

Plot 1-2, MinHang Export Processing ZoneNo. 3111 Huan Cheng West RoadFengxian District, Shanghai 201401,China

Tel. +86 21 3365 5333,Fax +86 21 3365 5331

[email protected]

www.helkamabica.fi

08/2010