© 2003 Schneider Electric All Rights Reserved BUILD YOUR OWN NF & NQOD P ANELBOARDS FROM STOCK . . . TODAY ! D1600HO0301BP R0 Amp Rating Max. No. of Poles Main Lugs Main Breaker Interior Enclosure Interior Main Breaker Adapter Kit Enclosure Type 1 Type 3R, 12 Height in. Type 1 Type 3R, 12 Height in. 20 Inch Wide 14 inch Wide Enclosure & Trim Kit (20” only) 20 Inch Wide 14 Inch Wide Enclosure & Trim Kit (20” only) 1 Phase 3 Wire 3 Phase 4 Wire Box MONO FLAT Front Trim (F) flush (S) surface Box MONO FLAT Front Trim (F) flush (S) surface 1 Phase 3 Wire 3 Phase 4 Wire 1 Phase 3 Wire 3 Phase 4 Wire Box MONO FLAT Front Trim (F) flush (S) surface Box MONO FLAT Front Trim (F) flush (S) surface 100 12 NQOD12L100CU NQOD412L100CU MH20 MHC20( ) NQB520 NQC20( ) MH20WP 20 NQOD12M100CU NQOD412M100CU Factory Installed Backfed QOB Main Breaker Factory Installed Backfed QOB Main Breaker MH23 MHC23( ) NQB523 NQC23( ) MH23WP 23 20 NQOD20L100 MH23 MHC23( ) NQB523 NQC23( ) MH23WP 23 NQOD20M100 MH26 MHC26( ) NQB526 NQC26( ) MH26WP 26 20 NQOD20L100CU MH23 MHC23( ) NQB523 NQC23( ) MH23WP 23 NQOD20M100CU MH26 MHC26( ) NQB526 NQC26( ) MH26WP 26 24 NQOD424L100 MH23 MHC23( ) MH23WP 23 NQOD424M100 MH26 MHC26( ) NQB526 NQC26( ) MH26WP 26 24 NQOD424L100CU MH23 MHC23( ) MH23WP 23 NQOD424M100CU MH26 MHC26( ) NQB526 NQC26( ) MH26WP 26 30 NQOD430L100NL MH29 MHC29( ) MH29WP 29 NQOD430M100NL MH32 MHC32( ) MH32WP 32 30 NQOD430L100CUNL MH29 MHC29( ) MH29WP 29 NQOD430M100CUNL MH32 MHC32( ) MH32WP 32 30 NQOD430L100 MH26 MHC26( ) NQB526 NQC26( ) MH26WP 26 NQOD430M100 MH29 MHC29( ) NQB529 NQC29( ) MH29WP 29 30 NQOD430L100CU MH26 MHC26( ) NQB526 NQC26( ) MH26WP 26 NQOD430M100CU MH29 MHC29( ) NQB529 NQC29( ) MH29WP 29 225 30 NQOD30L225 NQOD430L225 MH32 MHC32( ) NQB532 NQC32( ) MH32WP 32 NQOD30L225 NQOD430L225 Standard Neutral: NQOD-QB and desired 2 pole QBL/QDL/QGL/ QJL circuit breaker 200% Neutral: NQODKA and desired 2 pole KAL/KHL/KCL/ KIL 225A maximum circuit breaker Standard Neutral: NQOD-QB and desired 3 pole QBL/QDL/QGL/ QJL circuit breaker 200% Neutral: NQODKA and desired 3 pole KAL/KHL/KCL/ KIL 225A maximum circuit breaker MH44 MHC44( ) NQB544 NQC44( ) MH44WP 44 30 NQOD30L225CU NQOD430L225CU MH32 MHC32( ) NQB532 NQC32( ) MH32WP 32 NQOD30L225CU NQOD430L225CU MH44 MHC44( ) NQB544 NQC44( ) MH44WP 44 42 NQOD42L225 NQOD442L225 MH35 MHC35( ) NQB535 NQC35( ) MH35WP 35 NQOD42L225 NQOD442L225 MH50 MHC50( ) NQB550 NQC50( ) MH50WP 50 42 NQOD42L225TFL NQOD442L225TFL MH47 MHC47( ) MH47WP 47 NQOD42L225TFL NQOD442L225TFL MH62 MHC62( ) MH62WP 62 42 NQOD42L225CU NQOD442L225CU MH35 MHC35( ) NQB535 NQC35( ) MH35WP 35 NQOD42L225CU NQOD442L225CU MH50 MHC50( ) NQB550 NQC50( ) MH50WP 50 42 NQOD442L225NL MH38 MHC38( ) MH38WP 38 NQOD442L225NL MH50 MHC50( ) MH50WP 50 42 NQOD442L225CUNL MH38 MHC38( ) MH38WP 38 NQOD442L225CUNL MH50 MHC50( ) MH50WP 50 42 NQOD42L225CUTF NQOD442L225CUTF MH47 MHC47( ) MH47WP 47 NQOD42L225CUTF NQOD442L225CUTF MH62 MHC62( ) MH62WP 62 54 NQOD54L225 NQOD454L225 MH41 MHC41( ) NQB541 NQC41( ) MH41WP 41 NQOD54L225 NQOD454L225 MH56 MHC56( ) NQB556 NQC56( ) MH56WP 56 54 NQOD54L225CU NQOD454L225CU MH41 MHC41( ) NQB541 NQC41( ) MH41WP 41 NQOD54L225CU NQOD454L225CU MH56 MHC56( ) NQB556 NQC56( ) MH56WP 56 72 NQOD72L225 NQOD472L225 MH47 MHC47( ) MH47WP 47 NQOD72L225 NQOD472L225 MH62 MHC62( ) MH62WP 62 72 NQOD72L225CU NQOD472L225CU MH47 MHC47( ) MH47WP 47 NQOD72L225CU NQOD472L225CU MH62 MHC62( ) MH62WP 62 84 NQOD84L225 NQOD484L225 MH50 MHC50( ) MH50WP 50 NQOD84L225 NQOD484L225 MH65 MHC65( ) MH65WP 65 84 NQOD84L225CU NQOD484L225CU MH50 MHC50( ) MH50WP 50 NQOD84L225CU NQOD484L225CU MH65 MHC65( ) MH65WP 65 400 30 NQOD30L400 NQOD430L400 MH50 MHC50V( ) Use CU 50 NQOD30L400 NQOD430L400 NQOD4 and desired 2 pole LAL/LHLcircuit breaker NQOD4 and desired 3 pole LAL/LHL circuit breaker MH65 MHC65V( ) Use CU 65 30 NQOD30L400CU NQOD430L400CU MH50 MHC50V( ) MH50WP 50 NQOD30L400CU NQOD430L400CU MH65 MHC65V( ) MH65WP 65 42 NQOD42L400 NQOD442L400 MH53 MHC53V( ) Use CU 53 NQOD42L400 NQOD442L400 MH68 MHC68V( ) Use CU 68 42 NQOD42L400CU NQOD442L400CU MH53 MHC53V( ) MH53WP 53 NQOD42L400CU NQOD442L400CU MH68 MHC68V( ) MH68WP 68 42 NQOD42L600TFL NQOD442L600TFL MH77 MHC77V( ) MH77WP 77 42 NQOD442L400NL MH53 MHC53V( ) Use CU 53 NQOD442L400NL MH68 MHC68V( ) Use CU 68 42 NQOD442L400CUNL MH53 MHC53V( ) MH53WP 53 NQOD442L400CUNL MH68 MHC68V( ) MH68WP 68 54 NQOD54L400 NQOD454L400 MH59 MHC59V( ) Use CU 59 NQOD54L400 NQOD454L400 MH74 MHC74V( ) Use CU 74 54 NQOD54L400CU NQOD454L400CU MH59 MHC59V( ) MH59WP 59 NQOD54L400CU NQOD454L400CU MH74 MHC74V( ) MH74WP 74 72 NQOD72L400 NQOD472L400 MH65 MHC65V( ) MH65WP 65 NQOD72L400 NQOD472L400 MH80 MHC80V( ) MH80WP 80 72 NQOD72L400CU NQOD472L400CU MH65 MHC65V( ) MH65WP 65 NQOD72L400CU NQOD472L400CU MH80 MHC80V( ) MH80WP 80 84 NQOD84L400 NQOD484L400 MH68 MHC68V( ) MH68WP 68 84 NQOD84L400CU NQOD484L400CU MH68 MHC68V( ) MH68WP 68 600 30 NQOD30L600 NQOD430L600 MH53 MHC53V( ) 65 42 NQOD42L600 NQOD442L600 MH56 MHC56V( ) 68 42 NQOD42L600TFL NQOD442L600TFL MH62 MHC62V( ) 74 54 NQOD54L600 NQOD454L600 MH62 MHC62V( ) 74 72 NQOD72L600 NQOD472L600 MH65 MHC65V( ) 65 84 NQOD84L600 NQOD484L600 MH68 MHC68V( ) 68 Amp Ratings Max. No. of Poles Main Lugs Main Breaker Interior Enclosure (20” wide) Interior Main Breaker Adapter Kit Enclosure (20” wide) Type 1 Type 3R, 12 Type 1 Type 3R, 12 1 Phase 3 Wire 3 Phase 4 Wire Box MONO FLAT Front Trim (F) flush (S) surface Enclosure & Trim Kit Height in. 1 Phase 3 Wire 3 Phase 4 Wire System 1 Phase 3 Wire System 3 Phase 4 Wire Box MONO FLAT Front Trim (F) flush (S) surface Enclosure & Trim Kit Height in. 100 (*4) 12 NF12L1 NF412L1 N100MFI and 2 pole FIL circuit breaker N100MFI and 3 pole FIL circuit breaker MH38 NC38( ) MH38WP 38 12 NF12L1C NF412L1C MH38 NC38( ) MH38WP 38 18 NF18L1 NF418L1 MH38 NC38( ) MH38WP 38 18 NF18L1C NF418L1C MH38 NC38( ) MH38WP 38 30 NF30L1 NF430L1 MH44 NC44( ) MH44WP 44 30 NF30L1C NF430L1C MH44 NC44( ) MH44WP 44 30 NF30L1N NF430L1N MH44 NC44( ) MH44WP 44 30 NF30L1CN NF430L1CN MH44 NC44( ) MH44WP 44 125 (MLO) 110 (MB) (*4) 12 NF12L1 NF412L1 MH26 NC26( ) MH26WP 26 12 NF12L1C NF412L1C MH26 NC26( ) MH26WP 26 18 NF18L1 NF418L1 MH26 NC26( ) MH26WP 26 NF18L1 NF418L1 No kit needed. Select a 2-pole EDB, EGB or EJB breaker. Uses two poles of mounting space. No kit needed. Select a 3-pole EDB, EGB or EJB breaker. Uses three poles of mounting space. MH26 NC26( ) MH26WP 26 18 NF18L1C NF418L1C MH26 NC26( ) MH26WP 26 NF18L1C NF418L1C MH26 NC26( ) MH26WP 26 30 NF30L1 NF430L1 MH32 NC32( ) MH32WP 32 NF30L1 NF430L1 MH32 NC32( ) MH32WP 32 30 NF30L1C NF430L1C MH32 NC32( ) MH32WP 32 NF30L1C NF430L1C MH32 NC32( ) MH32WP 32 30 NF430L1N MH32 NC32( ) MH32WP 32 NF430L1N MH32 NC32( ) MH32WP 32 30 NF430L1CN MH32 NC32( ) MH32WP 32 NF430L1CN MH32 NC32( ) MH32WP 32 250 (*4) 18 NF18L2 NF418L2 MH32 NC32( ) MH32WP 32 NF18L2 NF418L2 N250MKC and desired 2 pole KAL/KHL/KI L circuit breaker N250MKC and desired 3 pole KAL/KHL/KIL circuit breaker MH44 NC44( ) MH44WP 44 18 NF18L2C NF418L2C MH32 NC32( ) MH32WP 32 NF18L2C NF418L2C MH44 NC44( ) MH44WP 44 30 NF30L2 NF430L2 MH38 NC38( ) MH38WP 38 NF30L2 NF430L2 MH50 NC50( ) MH50WP 50 30 NF30L2C NF430L2C MH38 NC38( ) MH38WP 38 NF30L2C NF430L2C MH50 NC50( ) MH50WP 50 42 NF42L2 NF442L2 MH44 NC44( ) MH44WP 44 NF42L2 NF442L2 MH56 NC56( ) MH56WP 56 42 NF42L2C NF442L2C MH44 NC44( ) MH44WP 44 NF42L2C NF442L2C MH56 NC56( ) MH56WP 56 42 NF442L2N MH44 NC44( ) MH44WP 44 NF442L2N MH56 NC56( ) MH56WP 56 42 NF442L2CN MH44 NC44( ) MH44WP 44 NF442L2CN MH56 NC56( ) MH56WP 56 54 NF54L2 NF454L2 MH50 NC50( ) MH50WP 50 NF54L2 NF454L2 MH62 NC62( ) MH62WP 62 54 NF54L2C NF454L2C MH50 NC50( ) MH50WP 50 NF54L2C NF454L2C MH62 NC62( ) MH62WP 62 66 NF66L2 NF466L2 MH62 NC62( ) MH62WP 62 66 NF66L2C NF466L2C MH62 NC62( ) MH62WP 62 400 18 NF18L4 NF418L4 MH44 NC44V( ) MH44WP 44 NF18L4 NF418L4 N400M and desired 2 pole LAL/LHL circuit breaker N400M and desired 3 pole LAL/LHL circuit breaker MH56 NC56V( ) MH56WP 56 18 NF18L4C NF418L4C MH44 NC44V( ) MH44WP 44 NF18L4C NF418L4C MH56 NC56V( ) MH56WP 56 30 NF30L4 NF430L4 MH50 NC50V( ) MH50WP 50 NF30L4 NF430L4 MH62 NC62V( ) MH62WP 62 30 NF30L4C NF430L4C MH50 NC50V( ) MH50WP 50 NF30L4C NF430L4C MH62 NC62V( ) MH62WP 62 42 NF42L4 NF442L4 MH56 NC56V( ) MH56WP 56 NF42L4 NF442L4 MH68 NC68V( ) MH68WP 68 42 NF42L4C NF442L4C MH56 NC56V( ) MH56WP 56 NF42L4C NF442L4C MH68 NC68V( ) MH68WP 68 42 NF442L4N MH56 NC56V( ) MH56WP 56 NF442L4N MH68 NC68V( ) MH68WP 68 42 NF442L4CN MH56 NC56V( ) MH56WP 56 NF442L4CN MH68 NC68V( ) MH68WP 68 54 NF54L4 NF454L4 MH62 NC62V( ) MH62WP 62 NF54L4 NF454L4 MH74 NC74V( ) MH74WP 74 54 NF54L4C NF454L4C MH62 NC62V( ) MH62WP 62 NF54L4C NF454L4C MH74 NC74V( ) MH74WP 74 66 NF66L4 NF466L4 MH74 NC74V( ) MH74WP 74 66 NF66L4C NF466L4C MH74 NC74V( ) MH74WP 74 84 NF84L4 NF484L4 MH86 NC86V( ) MH86WP 86 84 NF84L4C NF484L4C MH86 NC86V( ) MH86WP 86 600 30 NF30L6C NF430L6C MH50 NC50V( ) 50 42 NF42L6C NF442L6C MH56 NC56V( ) 56 54 NF54L6C NF454L6C MH62 NC62V( ) 62 66 NF66L6C NF466L6C MH74 NC74V( ) 74 84 NF84L6C NF484L6C MH86 NC86V( ) 86 QO Bolt-On Circuit Breakers QOB Bolt-On Ground Fault Circuit Interrupters QOB Bolt-On Arc Fault Circuit Interrupters Ampere Rating One Pole Two Pole Common Trip Three Pole Common Trip Wire Sizes Wire Temp. Al Cu 10 QOB110 QOB210 QOB310 #14-8 #14-8 60/75 o C 15 QOB115 QOB215 QOB315 #14-8 #14-8 60/75 o C 20 QOB120 QOB220 QOB320 #14-8 #14-8 60/75 o C 25 QOB125 QOB225 QOB325 #14-8 #14-8 60/75 o C 30 QOB130 QOB230 QOB330 #14-8 #14-8 60/75 o C 35 QOB135 QOB235 QOB335 #8-2 #8-2 75 o C 40 QOB140 QOB240 QOB340 #8-2 #8-2 75 o C 45 QOB145 QOB245 QOB345 #8-2 #8-2 75 o C 50 QOB150 QOB250 QOB350 #8-2 #8-2 75 o C 60 QOB160 QOB260 QOB360 #8-2 #8-2 75 o C 70 QOB170 QOB270 QOB370 #8-2 #8-2 75 o C 80 QOB280 QOB380 #4-2/0 #4-2/0 75 o C 90 QOB290 QOB390 #4-2/0 #4-2/0 75 o C 100 QOB2100 QOB3100 #4-2/0 #4-2/0 75 o C 110 QOB2110 #4-2/0 #4-2/0 75 o C 125 QOB2125 #4-2/0 #4-2/0 75 o C Ampere Rating One Pole Two Pole Common Trip Three Pole Common Trip Wire Sizes Wire Temp. Al Cu 15 QOB115GFI QOB215GFI #12-8 #14-8 60/75 o C 20 QOB120GFI QOB220GFI #12-8 #14-8 60/75 o C 25 QOB125GFI QOB225GFI #12-8 #14-8 60/75 o C 30 QOB130GFI QOB230GFI #12-8 #14-8 60/75 o C 40 QOB240GFI #12-4 #14-6 60/75 o C 50 QOB250GFI #12-4 #14-6 60/75 o C 60 QOB260GFI #8-4 75 o C Ampere Rating One Pole Two Pole Common Trip Three Pole Common Trip Wire Sizes Al or Cu Wire Temp. 15 QOB115AFI #14-8 60/75 o C 20 QOB120AFI #14-8 60/75 o C Uses popular QO ® branch Circuit breakers 200% rated neutrals for non-linear loads Interiors are field convertible for top or bottom feed Convertible from main lug to main breaker Improved AIR ratings ... up to 25 kA at 600Y/347 VAC. Improved series ratings 200% rated neutrals for non-linear loads HID and SWD rated branch circuit breakers Convertible from main lug to main breaker NQOD 240 Vac Max. NF 600Y/347 Vac Max. NQOD Accessories Description Catalogue No. Aluminum Entry Plate MHCOEW20A Fibre Entry Plate MHCOEW20F Drip Hood - 20” Wide Enclosure MHT2DH20 Drip Hood - 14” Wide Enclosure MHT2DH14 Barrier for Backfed Main Breaker - 20” Enclosure NQODBFMB20 Barrier for Backfed Main Breaker - 14” Enclosure NQODBFMB20 Double Tub Nipple Kit - Flush DTNKF Double Tub Nipple Kit - Surface DTNKS Main Breaker Adapter Kit: Std. NQOD-QB 200%N NQODKA Sub-feed lug kits–main lugs only–1Ø or 3Ø : 100A NQOD100SFL 225A NQOD225SFL Sub-feed: Plug-on: 2-Pole QO2125SL 3-Pole QO3125SL Sub-feed: Bolt-on: 2-Pole QOB2125SL 3-Pole QOB3125SL Equipment ground bars: 12 circuit 225A max. PK9GTA 20 circuit 225A max. PK12GTA 24 circuit 225A max. PK15GTA 30 circuit 225A max. PK18GTA 54 circuit 225A max. PK23GTA 54 circuit 600A max. PK27GTA PK15GTA with #1 to 4/0 Al/Cu lug PK15GTA-L PK18GTA with #1 to 4/0 Al/Cu lug PK18GTA-L PK23GTA with #1 to 4/0 Al/Cu lug PK23GTA-L Ground bar insulator kit PKGTAB Filler plate QOFP Directory cards (1 per package) 8003115801 Plastic directory pouch (1 per pkg) 8003115901 Circuit I.D. number strips #1-96 8004329503 Lock - for MONO-FLAT fronts PK22FL Key – NSR-251 (for all locks) LP9618 Touch-up paint USAS #49 Gray PK49SP Handle attachments–branch breakers: Handle lock-off HLO-1 Handle-tie - (QO & QOB only) QO1HT Handle padlock attachment - 1-Pole QO1PA 2 and 3-Pole QO1PL Combination handle-tie and lock-off Three 1-Pole (QO, QOB) QO3HT Neutral Lugs: #10 to #2 Al or #14 to #4 Cu QO70AN #4 to #1/0 Al/Cu Q1100AN #1 to #4/0 Al/Cu Q1150AN Endwalls for MH Boxes: Blank 8011010501 With Knockouts 8011010401 Elevating Nuts (4 required/1 per pkg): 100-600A 2342702200 42 circuit panelboard requires MH38 box, 54 circuit panelboard requires MH44 box. NF Accessories Description Catalogue No. Aluminum Entry Plate MHCOEW20A Fibre Entry Plate MHCOEW20F Drip Hood - 20” Wide Enclosure MHT2DH20 Barrier for Backfed Main Breaker - 20” Enclosure (Note 1) NFBFMB20 Double Tub Nipple Kit - Flush DTNKF Double Tub Nipple Kit - Surface DTNKS Equipment ground bars: 12 circuit 250A max. PK9GTA 18 circuit 250A max. PK12GTA 30 circuit 250A max. PK18GTA 42 circuit 250A max. PK23GTA 54 circuit 250A max. PK23GTA 54 circuit 600A max. PK27GTA PK18GTA with #1 to 4/0 Al/Cu lug PK18GTA-L PK23GTA with #1 to 4/0 Al/Cu lug PK23GTA-L Ground bar insulator kit PKGTAB Circuit I.D. number strips: #1-96 (1 per package) 8004337903 Filler plate EFP Lock - NEMA Type 1 enclosures PK22FL Key – NSR-251 (for all locks) LP9618 Directory cards (1 per package) 8003115801 Plastic directory pouch (1 per pkg) 8003115901 Handle attachments - branch breakers: Handle lockoff/padlock attachment HPAFD Nut - interior mounting (4 required/1 per pkg) 2322000003 Leveling nut (flush mount only - 4 per pkg) NFLN Trim/Mounting Screws/Hardware: 250A max interiors (10 per pkg) NFTMS1 800A max interiors (8 per pkg) LP9502 E-Frame Branch Circuit Breakers ( ) Complete catalogue number with letter for desired interrupting rating shown below. Interrupting Ratings (kA) Ampere Rating One Pole 347 Vac Two Pole 600/347 Vac Three Pole 600/347 Vac Wire Sizes Al or Cu 15 E( )B 16015 E( )B 26015 E( )B 36015 AL30FD #4-#6 20 E( )B 16020 E( )B 26020 E( )B 36020 25 E( )B 16025 E( )B 26025 E( )B 36025 30 E( )B 16030 E( )B 26030 E( )B 36030 35 E( )B 16035 E( )B 26035 E( )B 36035 AL100FD #4-2/0 40 E( )B 16040 E( )B 26040 E( )B 36040 45 E( )B 16045 E( )B 26045 E( )B 36045 50 E( )B 16050 E( )B 26050 E( )B 36050 60 E( )B 16060 E( )B 26060 E( )B 36060 70 E( )B 16070 E( )B 26070 E( )B 36070 80 E( )B 26080 E( )B 36080 90 E( )B 26090 E( )B 36090 100 E( )B 26100 E( )B 36100 110 E( )B 26110 E( )B 36110 EDB EGB EJB 120V 25 65 100 240V 18 (1P only), 25 35 (1P only), 65 65 (1P only), 100 480Y/277V 18 35 65 600Y/347Y 14 18 25 Main lug panel Main breaker panel Catalogue Number Logic Example *Notes: 1: Back-fed main breaker barrier, part # NFBFMB20, should be ordered and installed for every back-fed main breaker application, when converting a MLO panel into main breaker panel using a EDB, EGB or EJB breaker branch. Backfed main breaker takes up 2 poles (1P3W) or 3 poles (3P4W) of branch mounting space. Maximum branch breaker size to be mounted across a 110A backfed main is 60A. 2: Double tub kits can be used to increase no. of poles above 84. 3: For more information on NF & NQOD panelboards, please see data bulletin containing the Square D Digest pages. 4: Total amperage for 2 branch breakers mounted across from each other is limited to 170A for 250A interiors and below. Back-fed main application (see Note 1) 1 2 1 3 5 6 4 5 6 7 8 8 7 What you need: Box/Enclosure MLO Interior Cover/Trim Branch Breakers Accessories How to build your panel in 8 EASY steps: 1. Select voltage/type of panel 2. Select amperage rating 3. Select number of branch circuits required 4. Select main lugs or main circuit breaker 5. Select system (phase/wire), determine interior catalogue number and main breaker kit if required 6. Select enclosure type, determine box and trim catalogue numbers 7. Select branch circuit breakers 8. Select accessories 2 1 6 7 8 3 4 5 Optional Main Breaker Kit NQOD 4 42 L 225 CU TF 4 = Three phase,4-wire L = Main Lugs M = Main Breaker NQOD- 240 V No Digit = Single phase 3-wire No. of pole spaces Amps (For NF: 1=125, 2=250, 4=400, 6=600) C or Cu = Copper Bussing TF or TFL = Feed-thru Lugs NF 480Y/277 V 600Y/347 V Main lug panel Main breaker panel 5 2 3 5 6 4 5 6 5 Schneider Electric NEW1600DB0301 MB1.fm Page 1 Tuesday, July 15, 2003 4:35 PM

8. Select accessories 7. Select branch circuit breakers .... Select accessories 7. Select branch circuit breakers ... ... Circuit

  • Upload
    buithu

  • View
    275

  • Download
    7

Embed Size (px)

Citation preview

Page 1: 8. Select accessories 7. Select branch circuit breakers .... Select accessories 7. Select branch circuit breakers ... ... Circuit

© 2003 S

chneider Electric A

ll Rights R

eserved

B

UILD

Y

OUR

O

WN

NF &

NQOD

P

ANELBOARDS

F ROM

S

TOCK

. . . T

ODAY

!

D1600H

O0301B

P R

0

Amp

Rating

Max.

No. of Poles

Main Lugs

Main Breaker

InteriorEnclosure

InteriorM

ain Breaker Adapter KitEnclosure

Type 1Type 3R, 12

Heightin.

Type 1Type 3R, 12

Heightin.

20 Inch Wide

14 inch Wide

Enclosure &

Trim Kit

(20” only)

20 Inch Wide

14 Inch Wide

Enclosure &

Trim Kit

(20” only)1 Phase 3 W

ire3 Phase 4 W

ireBox

MONO

FLAT Front Trim

(F) flu

sh (S

) surface

Box

MONO

FLAT Front Trim

(F) flu

sh (S

) surface

1 Phase 3 Wire

3 Phase 4 Wire

1 Phase 3 Wire

3 Phase 4 Wire

Box

MONO

FLAT Front Trim

(F) flu

sh (S

) surface

Box

MONO

FLAT Front Trim

(F) flu

sh (S

) surface

100

12N

QO

D12L100C

U

NQ

OD

412L100CU

MH

20M

HC

20( )N

QB

520N

QC

20( )M

H20W

P20

NQ

OD

12M100C

UN

QO

D412M

100CU

Facto

ry Installed

Backfed

QO

BM

ain B

reaker

Facto

ry Installed

Backfed

QO

BM

ain B

reaker

MH

23M

HC

23( )N

QB

523N

QC

23( )M

H23W

P23

20N

QO

D20L100

MH

23M

HC

23( )N

QB

523N

QC

23( )M

H23W

P23

NQ

OD

20M100

MH

26M

HC

26( )N

QB

526N

QC

26( )M

H26W

P26

20N

QO

D20L100C

UM

H23

MH

C23( )

NQ

B523

NQ

C23( )

MH

23WP

23N

QO

D20M

100CU

MH

26M

HC

26( )N

QB

526N

QC

26( )M

H26W

P26

24N

QO

D424L100

MH

23M

HC

23( )M

H23W

P23

NQ

OD

424M100

MH

26M

HC

26( )N

QB

526N

QC

26( )M

H26W

P26

24N

QO

D424L100C

U

MH

23M

HC

23( )M

H23W

P23

NQ

OD

424M100C

UM

H26

MH

C26( )

NQ

B526

NQ

C26( )

MH

26WP

2630

NQ

OD

430L100NL

MH

29M

HC

29( )M

H29W

P29

NQ

OD

430M100N

LM

H32

MH

C32( )

MH

32WP

3230

NQ

OD

430L100CU

NL

MH

29M

HC

29( )M

H29W

P29

NQ

OD

430M100C

UN

LM

H32

MH

C32( )

MH

32WP

3230

NQ

OD

430L100 M

H26

MH

C26( )

NQ

B526

NQ

C26( )

MH

26WP

26N

QO

D430M

100M

H29

MH

C29( )

NQ

B529

NQ

C29( )

MH

29WP

2930

NQ

OD

430L100CU

M

H26

MH

C26( )

NQ

B526

NQ

C26( )

MH

26WP

26N

QO

D430M

100CU

M

H29

MH

C29( )

NQ

B529

NQ

C29( )

MH

29WP

29

225

30N

QO

D30L225

NQ

OD

430L225 M

H32

MH

C32( )

NQ

B532

NQ

C32( )

MH

32WP

32N

QO

D30L225

NQ

OD

430L225

Stan

dard

Neu

tral: N

QO

D-Q

B an

d

desired

2 po

le Q

BL

/QD

L/Q

GL

/ Q

JL circu

it b

reaker

200% N

eutral:

NQ

OD

KA

and

d

esired 2 p

ole

KA

L/K

HL

/KC

L/

KIL

225A

maxim

um

circuit

breaker

Stan

dard

Neu

tral: N

QO

D-Q

B an

d

desired

3 po

le Q

BL

/QD

L/Q

GL

/ Q

JL circu

it b

reaker

200% N

eutral:

NQ

OD

KA

and

d

esired 3 p

ole

KA

L/K

HL

/KC

L/

KIL

225A

maxim

um

circuit

breaker

MH

44M

HC

44( )N

QB

544N

QC

44( )M

H44W

P44

30N

QO

D30L225C

U

NQ

OD

430L225CU

M

H32

MH

C32( )

NQ

B532

NQ

C32( )

MH

32WP

32N

QO

D30L225C

UN

QO

D430L225C

U

MH

44M

HC

44( )N

QB

544N

QC

44( )M

H44W

P44

42N

QO

D42L225

NQ

OD

442L225 M

H35

MH

C35( )

NQ

B535

NQ

C35( )

MH

35WP

35N

QO

D42L225

NQ

OD

442L225 M

H50

MH

C50( )

NQ

B550

NQ

C50( )

MH

50WP

5042

NQ

OD

42L225TF

L N

QO

D442L225T

FL

MH

47M

HC

47( )M

H47W

P47

NQ

OD

42L225TF

LN

QO

D442L225T

FL

MH

62M

HC

62( )M

H62W

P62

42N

QO

D42L225C

UN

QO

D442L225C

U

MH

35M

HC

35( )N

QB

535N

QC

35( )M

H35W

P35

NQ

OD

42L225CU

NQ

OD

442L225CU

MH

50M

HC

50( )N

QB

550N

QC

50( )M

H50W

P50

42N

QO

D442L225N

L M

H38

MH

C38( )

MH

38WP

38N

QO

D442L225N

L M

H50

MH

C50( )

MH

50WP

5042

NQ

OD

442L225CU

NL

MH

38M

HC

38( )M

H38W

P38

NQ

OD

442L225CU

NL

MH

50M

HC

50( )M

H50W

P50

42N

QO

D42L225C

UT

F

NQ

OD

442L225CU

TF

M

H47

MH

C47( )

MH

47WP

47N

QO

D42L225C

UT

FN

QO

D442L225C

UT

F

MH

62M

HC

62( )M

H62W

P62

54N

QO

D54L225

NQ

OD

454L225 M

H41

MH

C41( )

NQ

B541

NQ

C41( )

MH

41WP

41N

QO

D54L225

NQ

OD

454L225 M

H56

MH

C56( )

NQ

B556

NQ

C56( )

MH

56WP

5654

NQ

OD

54L225CU

N

QO

D454L225C

U

MH

41M

HC

41( )N

QB

541N

QC

41( )M

H41W

P41

NQ

OD

54L225CU

NQ

OD

454L225CU

M

H56

MH

C56( )

NQ

B556

NQ

C56( )

MH

56WP

5672

NQ

OD

72L225 N

QO

D472L225

MH

47M

HC

47( )M

H47W

P47

NQ

OD

72L225N

QO

D472L225

MH

62M

HC

62( )M

H62W

P62

72N

QO

D72L225C

U

NQ

OD

472L225CU

M

H47

MH

C47( )

MH

47WP

47N

QO

D72L225C

UN

QO

D472L225C

U

MH

62M

HC

62( )M

H62W

P62

84N

QO

D84L225

NQ

OD

484L225 M

H50

MH

C50( )

MH

50WP

50N

QO

D84L225

NQ

OD

484L225 M

H65

MH

C65( )

MH

65WP

6584

NQ

OD

84L225CU

N

QO

D484L225C

U

MH

50M

HC

50( )M

H50W

P50

NQ

OD

84L225CU

NQ

OD

484L225CU

M

H65

MH

C65( )

MH

65WP

65

400

30N

QO

D30L400

NQ

OD

430L400 M

H50

MH

C50V

( )U

se CU

50N

QO

D30L400

NQ

OD

430L400

NQ

OD

4 and

d

esired 2 p

ole

LA

L/L

HL

circuit

breaker

NQ

OD

4 and

d

esired 3 p

ole

LA

L/L

HL

circuit

breaker

MH

65M

HC

65V( )

Use C

U65

30N

QO

D30L400C

U

NQ

OD

430L400CU

M

H50

MH

C50V

( )M

H50W

P50

NQ

OD

30L400CU

NQ

OD

430L400CU

M

H65

MH

C65V

( )M

H65W

P65

42N

QO

D42L400

NQ

OD

442L400 M

H53

MH

C53V

( )U

se CU

53N

QO

D42L400

NQ

OD

442L400 M

H68

MH

C68V

( )U

se CU

6842

NQ

OD

42L400CU

NQ

OD

442L400CU

MH

53M

HC

53V( )

MH

53WP

53N

QO

D42L400C

UN

QO

D442L400C

U

MH

68M

HC

68V( )

MH

68WP

6842

NQ

OD

42L600TF

LN

QO

D442L600T

FL

MH

77M

HC

77V( )

MH

77WP

7742

NQ

OD

442L400NL

MH

53M

HC

53V( )

Use C

U53

NQ

OD

442L400NL

MH

68M

HC

68V( )

Use C

U68

42N

QO

D442L400C

UN

L M

H53

MH

C53V

( )M

H53W

P53

NQ

OD

442L400CU

NL

MH

68M

HC

68V( )

MH

68WP

6854

NQ

OD

54L400 N

QO

D454L400

MH

59M

HC

59V( )

Use C

U59

NQ

OD

54L400N

QO

D454L400

MH

74M

HC

74V( )

Use C

U74

54N

QO

D54L400C

U

NQ

OD

454L400CU

M

H59

MH

C59V

( )M

H59W

P59

NQ

OD

54L400CU

NQ

OD

454L400CU

M

H74

MH

C74V

( )M

H74W

P74

72N

QO

D72L400

NQ

OD

472L400 M

H65

MH

C65V

( )M

H65W

P65

NQ

OD

72L400N

QO

D472L400

MH

80M

HC

80V( )

MH

80WP

8072

NQ

OD

72L400CU

N

QO

D472L400C

U

MH

65M

HC

65V( )

MH

65WP

65N

QO

D72L400C

UN

QO

D472L400C

UM

H80

MH

C80V

( )M

H80W

P80

84N

QO

D84L400

NQ

OD

484L400 M

H68

MH

C68V

( )M

H68W

P68

84N

QO

D84L400C

U

NQ

OD

484L400CU

M

H68

MH

C68V

( )M

H68W

P68

600

30N

QO

D30L600

NQ

OD

430L600 M

H53

MH

C53V

( )65

42N

QO

D42L600

NQ

OD

442L600 M

H56

MH

C56V

( )68

42N

QO

D42L600T

FL

NQ

OD

442L600TF

L M

H62

MH

C62V

( )74

54N

QO

D54L600

NQ

OD

454L600 M

H62

MH

C62V

( )74

72N

QO

D72L600

NQ

OD

472L600 M

H65

MH

C65V

( )65

84N

QO

D84L600

NQ

OD

484L600M

H68

MH

C68V

( )68

Amp

Ratings

Max.

No. of Poles

Main Lugs

Main Breaker

InteriorEnclosure (20” w

ide)Interior

Main Breaker Adapter Kit

Enclosure (20” wide)

Type 1Type 3R, 12

Type 1Type 3R, 12

1 Phase 3 Wire

3 Phase 4 Wire

Box

MONO

FLAT Front Trim

(F) flu

sh (S

) surface

Enclosure &

Trim Kit

Heightin.

1 Phase 3 Wire

3 Phase 4 Wire

System1 Phase 3 W

ireSystem

3 Phase 4 Wire

Box

MONO

FLAT Front Trim

(F) flu

sh (S

) surface

Enclosure &

Trim Kit

Heightin.

100

(*4)

12N

F12L1

NF

412L1

N100M

FI an

d 2 p

ole

FIL

circuit b

reakerN

100MF

I and

3 po

leF

IL circu

it breaker

MH

38N

C38( )

MH

38WP

3812

NF

12L1CN

F412L1C

MH

38N

C38( )

MH

38WP

3818

NF

18L1N

F418L1

MH

38N

C38( )

MH

38WP

3818

NF

18L1CN

F418L1C

MH

38N

C38( )

MH

38WP

3830

NF

30L1N

F430L1

MH

44N

C44( )

MH

44WP

4430

NF

30L1CN

F430L1C

MH

44N

C44( )

MH

44WP

4430

NF

30L1NN

F430L1N

MH

44N

C44( )

MH

44WP

4430

NF

30L1CN

NF

430L1CN

MH

44N

C44( )

MH

44WP

44

125 (M

LO

)

110 (MB

)

(*4)

12N

F12L1

NF

412L1M

H26

NC

26( )M

H26W

P26

12N

F12L1C

NF

412L1CM

H26

NC

26( )M

H26W

P26

18N

F18L1

NF

418L1M

H26

NC

26( )M

H26W

P26

NF

18L1N

F418L1

No

kit need

ed. S

elect a 2-p

ole E

DB

, EG

B o

r EJB

b

reaker. Uses tw

o

po

les of m

ou

ntin

g

space.

No

kit need

ed. S

elect a 3-p

ole E

DB

, EG

B o

r EJB

b

reaker. Uses th

ree p

oles o

f mo

un

ting

sp

ace.

MH

26N

C26( )

MH

26WP

2618

NF

18L1CN

F418L1C

MH

26N

C26( )

MH

26WP

26N

F18L1C

NF

418L1CM

H26

NC

26( )M

H26W

P26

30N

F30L1

NF

430L1M

H32

NC

32( )M

H32W

P32

NF

30L1N

F430L1

MH

32N

C32( )

MH

32WP

3230

NF

30L1CN

F430L1C

MH

32N

C32( )

MH

32WP

32N

F30L1C

NF

430L1CM

H32

NC

32( )M

H32W

P32

30N

F430L1N

MH

32N

C32( )

MH

32WP

32N

F430L1N

MH

32N

C32( )

MH

32WP

3230

NF

430L1CN

MH

32N

C32( )

MH

32WP

32N

F430L1C

NM

H32

NC

32( )M

H32W

P32

250

(*4)

18N

F18L2

NF

418L2M

H32

NC

32( )M

H32W

P32

NF

18L2N

F418L2

N250M

KC

and

desired

2 p

ole K

AL

/KH

L/K

I Lcircu

it breaker

N250M

KC

and

desired

3 p

ole K

AL

/KH

L/K

ILcircu

it breaker

MH

44N

C44( )

MH

44WP

4418

NF

18L2CN

F418L2C

MH

32N

C32( )

MH

32WP

32N

F18L2C

NF

418L2CM

H44

NC

44( )M

H44W

P44

30N

F30L2

NF

430L2M

H38

NC

38( )M

H38W

P38

NF

30L2N

F430L2

MH

50N

C50( )

MH

50WP

5030

NF

30L2CN

F430L2C

MH

38N

C38( )

MH

38WP

38N

F30L2C

NF

430L2CM

H50

NC

50( )M

H50W

P50

42N

F42L2

NF

442L2M

H44

NC

44( )M

H44W

P44

NF

42L2N

F442L2

MH

56N

C56( )

MH

56WP

5642

NF

42L2CN

F442L2C

MH

44N

C44( )

MH

44WP

44N

F42L2C

NF

442L2CM

H56

NC

56( )M

H56W

P56

42N

F442L2N

MH

44N

C44( )

MH

44WP

44N

F442L2N

MH

56N

C56( )

MH

56WP

5642

NF

442L2CN

MH

44N

C44( )

MH

44WP

44N

F442L2C

NM

H56

NC

56( )M

H56W

P56

54N

F54L2

NF

454L2M

H50

NC

50( )M

H50W

P50

NF

54L2N

F454L2

MH

62N

C62( )

MH

62WP

6254

NF

54L2CN

F454L2C

MH

50N

C50( )

MH

50WP

50N

F54L2C

NF

454L2CM

H62

NC

62( )M

H62W

P62

66N

F66L2

NF

466L2M

H62

NC

62( )M

H62W

P62

66N

F66L2C

NF

466L2CM

H62

NC

62( )M

H62W

P62

400

18N

F18L4

NF

418L4M

H44

NC

44V( )

MH

44WP

44N

F18L4

NF

418L4

N400M

and

desired

2 p

ole L

AL

/LH

L circu

it b

reaker

N400M

and

desired

3 p

ole L

AL

/LH

L circu

it b

reaker

MH

56N

C56V

( )M

H56W

P56

18N

F18L4C

NF

418L4CM

H44

NC

44V( )

MH

44WP

44N

F18L4C

NF

418L4CM

H56

NC

56V( )

MH

56WP

5630

NF

30L4N

F430L4

MH

50N

C50V

( )M

H50W

P50

NF

30L4N

F430L4

MH

62N

C62V

( )M

H62W

P62

30N

F30L4C

NF

430L4CM

H50

NC

50V( )

MH

50WP

50N

F30L4C

NF

430L4CM

H62

NC

62V( )

MH

62WP

6242

NF

42L4N

F442L4

MH

56N

C56V

( )M

H56W

P56

NF

42L4N

F442L4

MH

68N

C68V

( )M

H68W

P68

42N

F42L4C

NF

442L4CM

H56

NC

56V( )

MH

56WP

56N

F42L4C

NF

442L4CM

H68

NC

68V( )

MH

68WP

6842

NF

442L4NM

H56

NC

56V( )

MH

56WP

56N

F442L4N

MH

68N

C68V

( )M

H68W

P68

42N

F442L4C

NM

H56

NC

56V( )

MH

56WP

56N

F442L4C

NM

H68

NC

68V( )

MH

68WP

6854

NF

54L4N

F454L4

MH

62N

C62V

( )M

H62W

P62

NF

54L4N

F454L4

MH

74N

C74V

( )M

H74W

P74

54N

F54L4C

NF

454L4CM

H62

NC

62V( )

MH

62WP

62N

F54L4C

NF

454L4CM

H74

NC

74V( )

MH

74WP

7466

NF

66L4N

F466L4

MH

74N

C74V

( )M

H74W

P74

66N

F66L4C

NF

466L4CM

H74

NC

74V( )

MH

74WP

7484

NF

84L4N

F484L4

MH

86N

C86V

( )M

H86W

P86

84N

F84L4C

NF

484L4CM

H86

NC

86V( )

MH

86WP

86

600

30N

F30L6C

NF

430L6CM

H50

NC

50V( )

5042

NF

42L6CN

F442L6C

MH

56N

C56V

( )56

54N

F54L6C

NF

454L6CM

H62

NC

62V( )

6266

NF

66L6CN

F466L6C

MH

74N

C74V

( )74

84N

F84L6C

NF

484L6CM

H86

NC

86V( )

86

QO

Bo

lt-On

Circu

it Breakers

QO

B B

olt-O

n G

rou

nd

Fau

lt Circu

it Interru

pters

QO

B B

olt-O

n A

rc Fau

lt Circu

it Interru

pters

Am

pere

Ratin

gO

ne P

ole

Tw

o P

ole

Co

mm

on

T

rip

Th

ree Po

leC

om

mo

n

Trip

Wire S

izesW

ireT

emp

.A

lC

u

10Q

OB

110Q

OB

210Q

OB

310#14-8

#14-860/75

o

C

15Q

OB

115Q

OB

215Q

OB

315#14-8

#14-860/75

o

C

20Q

OB

120Q

OB

220Q

OB

320#14-8

#14-860/75

o

C

25Q

OB

125Q

OB

225Q

OB

325#14-8

#14-860/75

o

C

30Q

OB

130Q

OB

230Q

OB

330#14-8

#14-860/75

o

C

35Q

OB

135Q

OB

235Q

OB

335#8-2

#8-275

o

C

40Q

OB

140Q

OB

240Q

OB

340#8-2

#8-275

o

C

45Q

OB

145Q

OB

245Q

OB

345#8-2

#8-275

o

C

50Q

OB

150Q

OB

250Q

OB

350#8-2

#8-275

o

C

60Q

OB

160Q

OB

260Q

OB

360#8-2

#8-275

o

C

70Q

OB

170Q

OB

270Q

OB

370#8-2

#8-275

o

C

80Q

OB

280Q

OB

380#4-2/0

#4-2/075

o

C

90Q

OB

290Q

OB

390#4-2/0

#4-2/075

o

C

100Q

OB

2100Q

OB

3100#4-2/0

#4-2/075

o

C

110Q

OB

2110#4-2/0

#4-2/075

o

C

125Q

OB

2125#4-2/0

#4-2/075

o

C

Am

pere

Ratin

gO

ne P

ole

Tw

o P

ole

Co

mm

on

T

rip

Th

ree Po

leC

om

mo

n

Trip

Wire S

izesW

ireT

emp

.A

lC

u

15Q

OB

115GF

IQ

OB

215GF

I#12-8

#14-860/75

o

C20

QO

B120G

FI

QO

B220G

FI

#12-8#14-8

60/75

o

C25

QO

B125G

FI

QO

B225G

FI

#12-8#14-8

60/75

o

C30

QO

B130G

FI

QO

B230G

FI

#12-8#14-8

60/75

o

C40

QO

B240G

FI

#12-4#14-6

60/75

o

C50

QO

B250G

FI

#12-4#14-6

60/75

o

C60

QO

B260G

FI

#8-475

o

C

Am

pere

Ratin

gO

ne P

ole

Tw

o P

ole

Co

mm

on

T

rip

Th

ree Po

leC

om

mo

n

Trip

Wire S

izesA

l or C

uW

ireT

emp

.

15Q

OB

115AF

I#14-8

60/75

o

C20

QO

B120A

FI

#14-860/75

o

C

Uses popular Q

O

®

branch Circuit

breakers

200% rated neutrals for non-linear

loads

Interiors are field convertible for top or bottom

feed

Convertible from

main lug to m

ain breaker

Improved A

IR ratings ... up to 25 kA

at 600Y

/347 VA

C.

Improved series ratings

200% rated neutrals for non-linear

loads

HID

and SW

D rated branch circuit

breakers

Convertible from

main lug to m

ain breaker

NQ

OD

240 Vac M

ax.

NF

600Y/347 V

ac Max.

NQ

OD

Accesso

ries

Descrip

tion

Catalo

gu

e N

o.

Alum

inum E

ntry Plate

MH

CO

EW

20AF

ibre Entry P

lateM

HC

OE

W20F

Drip H

ood - 20” Wide E

nclosureM

HT

2DH

20D

rip Hood - 14” W

ide Enclosure

MH

T2D

H14

Barrier for B

ackfed Main

Breaker - 20” E

nclosureN

QO

DB

FM

B20

Barrier for B

ackfed Main

Breaker - 14” E

nclosureN

QO

DB

FM

B20

Double T

ub Nipple K

it - Flush

DT

NK

FD

ouble Tub N

ipple Kit - S

urfaceD

TN

KS

Main B

reaker Adapter K

it:S

td.N

QO

D-Q

B200%

NN

QO

DK

AS

ub-feed lug kits–main lugs only–1Ø

or 3Ø

:100A

NQ

OD

100SF

L225A

NQ

OD

225SF

LS

ub-feed: Plug-on: 2-P

oleQ

O2125S

L3-P

oleQ

O3125S

LS

ub-feed: Bolt-on:

2-Pole

QO

B2125S

L3-P

oleQ

OB

3125SL

Equipm

ent ground bars:12 circuit 225A

max.

PK

9GT

A20 circuit 225A

max.

PK

12GT

A24 circuit 225A

max.

PK

15GT

A30 circuit 225A

max.

PK

18GT

A54 circuit 225A

max.

PK

23GT

A54 circuit 600A

max.

PK

27GT

AP

K15G

TA

with #1 to 4/0 A

l/Cu lug

PK

15GT

A-L

PK

18GT

A w

ith #1 to 4/0 Al/C

u lugP

K18G

TA

-LP

K23G

TA

with #1 to 4/0 A

l/Cu lug

PK

23GT

A-L

Ground bar insulator kit

PK

GT

AB

Filler plate

QO

FP

Directory cards (1 per package)

8003115801P

lastic directory pouch (1 per pkg)8003115901

Circuit I.D

. number strips #1-96

8004329503Lock - for M

ON

O-F

LAT

frontsP

K22F

LK

ey – NS

R-251 (for all locks)

LP9618

Touch-up paint U

SA

S #49 G

rayP

K49S

PH

andle attachments–branch breakers:

Handle lock-off

HLO

-1H

andle-tie - (QO

& Q

OB

only)Q

O1H

TH

andle padlock attachment -

1-Pole

QO

1PA

2 and 3-Pole

QO

1PL

Com

bination handle-tie and lock-offT

hree 1-Pole (Q

O, Q

OB

)Q

O3H

TN

eutral Lugs: #10 to #2 A

l or #14 to #4 Cu

QO

70AN

#4 to #1/0 Al/C

uQ

1100AN

#1 to #4/0 Al/C

uQ

1150AN

Endw

alls for MH

Boxes:

Blank

8011010501W

ith Knockouts

8011010401E

levating Nuts (4 required/1 per pkg):

100-600A2342702200

42 circuit panelboard requires MH38 box,

54 circuit panelboard requires MH44 box.

NF

Accesso

ries

Descrip

tion

Catalo

gu

e N

o.

Alum

inum E

ntry Plate

MH

CO

EW

20AF

ibre Entry P

lateM

HC

OE

W20F

Drip H

ood - 20” Wide E

nclosureM

HT

2DH

20B

arrier for Backfed M

ain B

reaker - 20” Enclosure (N

ote 1)N

FB

FM

B20

Double T

ub Nipple K

it - Flush

DT

NK

FD

ouble Tub N

ipple Kit - S

urfaceD

TN

KS

Equipm

ent ground bars:12 circuit 250A

max.

PK

9GT

A18 circuit 250A

max.

PK

12GT

A30 circuit 250A

max.

PK

18GT

A42 circuit 250A

max.

PK

23GT

A54 circuit 250A

max.

PK

23GT

A54 circuit 600A

max.

PK

27GT

AP

K18G

TA

with #1 to 4/0 A

l/Cu lug

PK

18GT

A-L

PK

23GT

A w

ith #1 to 4/0 Al/C

u lugP

K23G

TA

-LG

round bar insulator kitP

KG

TA

BC

ircuit I.D. num

ber strips:#1-96 (1 per package)

8004337903F

iller plateE

FP

Lock - NE

MA

Type 1 enclosures

PK

22FL

Key – N

SR

-251 (for all locks)LP

9618D

irectory cards (1 per package)8003115801

Plastic directory pouch (1 per pkg)

8003115901H

andle attachments - branch breakers:

Handle lockoff/padlock attachm

entH

PA

FD

Nut - interior m

ounting (4 required/1 per pkg)

2322000003Leveling nut (flush m

ount only - 4 per pkg)

NF

LN

Trim

/Mounting S

crews/H

ardware:

250A m

ax interiors (10 per pkg)N

FT

MS

1800A

max interiors (8 per pkg)

LP9502

E-F

rame B

ranch

Circu

it Breakers

( ) Complete catalogue num

ber with letter for desired interrupting rating

shown below

.

Interru

ptin

g R

ating

s (kA)

Am

pere

Ratin

gO

ne P

ole

347 Vac

Tw

o P

ole

600/347 Vac

Th

ree Po

le600/347 V

acW

ire Sizes

Al o

r Cu

15E

( )B 16015

E( )B

26015E

( )B 36015

AL30F

D#4-#6

20E

( )B 16020

E( )B

26020E

( )B 36020

25E

( )B 16025

E( )B

26025E

( )B 36025

30E

( )B 16030

E( )B

26030E

( )B 36030

35E

( )B 16035

E( )B

26035E

( )B 36035

AL100F

D

#4-2/0

40E

( )B 16040

E( )B

26040E

( )B 36040

45E

( )B 16045

E( )B

26045E

( )B 36045

50E

( )B 16050

E( )B

26050E

( )B 36050

60E

( )B 16060

E( )B

26060E

( )B 36060

70E

( )B 16070

E( )B

26070E

( )B 36070

80E

( )B 26080

E( )B

36080

90E

( )B 26090

E( )B

36090

100E

( )B 26100

E( )B

36100

110E

( )B 26110

E( )B

36110

ED

BE

GB

EJB

120V25

65100

240V18 (1P

only), 2535 (1P

only), 6565 (1P

only), 100480Y

/277V18

3565

600Y/347Y

1418

25

Main lug panel

Main breaker panel

Catalogue Number Logic Exam

ple

*Notes: 1:

Back-fed main breaker barrier, part # NFBFM

B20, should be ordered and installed for every back-fed main breaker application,

when converting a M

LO panel into main breaker panel using a EDB, EGB or EJB breaker branch. Backfed m

ain breaker takes up 2poles (1P3W

) or 3 poles (3P4W) of branch m

ounting space. Maxim

um branch breaker size to be m

ounted across a 110A backfedm

ain is 60A.2:

Double tub kits can be used to increase no. of poles above 84.3:

For more inform

ation on NF & NQOD panelboards, please see data bulletin containing the Square D Digest pages.

4:Total am

perage for 2 branch breakers mounted across from

each other is limited to 170A for 250A interiors and below

.

Back-fed

main

app

lication

(see No

te 1)

12

1

3

5

64

5

67

887

What you need:

Box/Enclosure

MLO

Interior

Cover/Trim

Branch Breakers

Accessories

How to build your panel in 8 EASY steps:

1.Select voltage/type of panel

2.Select am

perage rating

3.Select num

ber of branch circuits required

4.Select m

ain lugs or main circuit breaker

5.Select system

(phase/wire), determ

ineinterior catalogue num

ber and main

breaker kit if required

6.Select enclosure type, determ

ine box andtrim

catalogue numbers

7.Select branch circuit breakers

8.Select accessories

2 1678 345

Optional M

ain Breaker Kit

NQ

OD

4 42 L 225 CU

TF

4 = T

hree phase,4-w

ire

L = M

ain LugsM

= M

ain Breaker

NQ

OD

-240 V

No D

igit =

Single phase

3-wire

No. of pole

spaces

Am

ps (For N

F:

1=125, 2=

250, 4=

400, 6=600)

C or C

u =

Copper

Bussing

TF

or T

FL =

F

eed-thru Lugs

NF

480Y/277 V

600Y/347 V

Main lug panel

Main breaker panel

5

23

56

4

56

5

Sch

ne

ide

r Ele

ctric

NE

W1600D

B0301 M

B1.fm

Page 1 Tuesday, July 15, 2003 4:35 PM

Page 2: 8. Select accessories 7. Select branch circuit breakers .... Select accessories 7. Select branch circuit breakers ... ... Circuit

NQ Panelboards

– Ready to Install (RTI)

20” Wide Enclosures—240 Vac, 48 Vdc

DE

5

PA

NE

LB

OA

RD

S

DE5-9

12/08

NQ

Box Sizing Requirements

Example

:NQ 225A 30 circuit MCB Panelboard with FTL in Type 1 surface enclosure:Basic interior: 32"MCB adder: 12"FTL adder: 6"

Required height: 50

" Box MH50, trim NC50S

Basic NQ MLO Panelboard Enclosure Sizes and Height Adders for Accessories

Mains Rating

Available Branch Circuits

Required Enclosure Height (in.)

Interior Only Type 1 Enclosure 3R/5/12 Space Factor (height adder for feature)

Single Phase

Three Phase Box Trim Complete

EnclosureVertical

MCB AI SFL FTL SFB 200% Neutral

10018 26 NQ18L1 NQ18L1 MH26 NC26( ) MH26WP

12" 0" 0" Not Available 0"

30 32 NQ30L1 NQ30L1 MH32 NC32( ) MH32WP

225

30 32 NQ30L2 NQ30L2 MH32 NC32( ) MH32WP

12" 6" (Cu=0")

6"

18" 0"

42 38 NQ42L2 NQ42L2 MH38 NC38( ) MH38WP 0"

54 38 NQ54L2 NQ54L2 MH38 NC38( ) MH38WP 6"

72 44 NQ72L2 NQ72L2 MH44 NC44( ) MH44WP 6"

84 50 NQ84L2 NQ84L2 MH50 NC50( ) MH50WP 6"

400

30 50 NQ30L4 NQ30L4 MH50 NC50V( ) MH50WP

12" 0

0"

24" 0"

42 50 NQ42L4 NQ42L4 MH50 NC50V( ) MH50WP 6"

54 56 NQ54L4 NQ54L4 MH56 NC56V( ) MH56WP 6"

72 62 N/A NQ472L4 MH62 NC62V( ) MH62WP 6"

84 68 NQ84L4C NQ84L4C MH68 NC68V( ) MH68WP 0"

600

30 50 NQ30L6C NQ30L6C MH50 NC50V( ) MH62WP

18" (LC/LI) Not Available

6" on each end - total

12"24" Not

Available

42 50 NQ42L6C NQ42L6C MH50 NC50V( ) MH62WP

54 56 NQ54L6C NQ54L6C MH56 NC56V( ) MH68WP

72 62 N/A NQ472L6C MH62 NC62V( ) MH74WP

84 68 NQ84L6C NQ84L6C MH68 NC68V( ) MH80WP

NQ RTI Accessories

Description Application Catalogue No.

Equipment Ground Bars

Aluminum PK27GTA

Copper PK27GTACU

Insulator Kit PKGTAB

PK23GTA + #1 to #4/0 Al/Cu lug Ground Bar with Lug PK23GTAL

Filler Plate (15 per package) Plastic Filler NQFP15

Directory Cards NQ Panelboard 80031 158 01

Plastic stick-on directory pouch NQ Panelboard 80031 159 01

Circuit Numbering Strips

Odd-Even 1-102 NQ102OE

Sequential 1-102 NQ102S

Odd-Even 103-204 NQ204OE

Sequential 103-204 NQ204S

Key - NSR-251 NEMA 1Locks LP9618

Key - DSR-251 NEMA 3R Locks DSR-251

Rail and Deadfront extensions

6” Extension NQ6RDE

12” Extension NQ12RDE

18” Extension NQ18RDE

24” Extension NQ24RDE

Handle Padlock Attachment Branches See Circuit Breaker Section

Mounting Nut (4 per pkg.) Interiors 23220 00003

Elevating Kit Flush only NQLN

Trim mounting screws / hardware

250A Max. Interiors (10 per pkg.) NFTMS1

400A/600A Interiors (8 per pkg.) LP9502

Branch mount bolt-on sub-feed2-pole QOB2125SL

3-pole QOB3125SL

Drip Hood for std encl. 20” Wide MHT2DH20

NQ 400A 42CCT MLOw/2 subfeed CB’s

DE5_P09.fm Page 9 Wednesday, January 7, 2009 4:20 PM

Page 3: 8. Select accessories 7. Select branch circuit breakers .... Select accessories 7. Select branch circuit breakers ... ... Circuit

NF Panelboards –

Ready To Install (RTI)

Accessories

DE

5

PA

NE

LB

OA

RD

S

DE5-15

12/08

NF RTI ( ready to install ) Accessories

Description Application Catalogue No.

Lock - Enclosures Type 1 PK22FL

Key - NSR-251 Type 1 encl. LP 9618

Key - DSR-251 Type 3R encl. DSR251

Handle Padlock Attachment Breakers HPAFD

Mounting Nut (4 per pkg.) Interiors 23220 000 03

Leveling Nut (4 per pkg.) Flush only NFLN

Trim Mounting Screws & Hardware

250A Max. Interiors (10 per pkg.) NFTMS1

800A Max Interiors (8 per pkg.) LP9502

Drip Hood for std encl. 20” Wide MHT2DH20

Aluminum Entry Plate MHCOEW20A

Fibre Entry Plate MHCOEW20F

Barrier for Backfed Main Breaker 20” Enclosure

NFBFMB20

Nipple Kit for Flush Mount Trims DTNKF

Nipple Kit for Surface Mount Trims DTNKS

Note:

In back-fed main breaker application the use of NFBFMB20 barrier is recommended. Please refer to local Electrical Codes or Authorities for specific local requirements.

Optional Main Lug Kits for NF Main Lug Panelboards

Use of this kit requires an additional 6” added to the box height.

Use of this kit to terminate larger than stadnard wire sites requires an additional 6” added to the box height.

Standard mechanical lugs for Main Lugs panels.

Amps

Aluminum Copper

Aluminum Mechanical

Aluminum Compression Copper Mechanical Copper Compression

Cat. # Lug Wire Range Cat. # Lug Wire Range Cat. # Lug Wire Range Cat. # Lug Wire Range

125 NFALM1 (1) #6–2/0 NFALV1

(1) #4–300 kcmil NFCUM1 (1) #6–350 kcmil NFCUV1

(1) #6–1/0

250 NFALM2 (1) #6–350 kcmil NFALV2 (1) 250–350 kcmil NFCUM2 (1) #6–350 kcmil NFCUV2

(1) 2/0–300 kcmil

400 NFALM4 (1) 1/0–750 kcmil or(2) 1/0–350 kcmil NFALV4 (2) 2/0–500 kcmil NFCUM4 (1) 1/0–750 kcmil or

(2) 1/0–350 kcmil NFCUV4 (1) 400–750 kcmil

600 NFALM6 (2) 1/0–600 kcmil NFALV6 (2) 2/0–500 kcmil NFCUM6 (2) 1/0–750 kcmil NFCUV6 (2) 250–500 kcmil

800 Factory Assembled Only – Contact Local Sales Office.

NF Main Neutral Conductors – Required Size and Quantity

Panelboard Ampacity Neutral Conductors Required Actual Lug

Wire Range

125 (1) #1 Cu, or (1) 2/0 Al (1) #6–2/0

250 (1) 250 kcmil Cu, or (1) 350 kcmil Al (1) #6–350 kcmil

400(1) 600 kcmil Cu, or

(2) 3/0 Cu, or (2) 250 kcmil Al(1) 1/0–750 kcmil(2) 1/0–300 kcmil

600 (2) 350 kcmil Cu, or (2) 500 kcmil Al (1) 1/0–750 kcmil(2) 1/0–300 kcmil

Ground bar PK27GTA200% Neutral Kit

Stainless Steel Type 4x Enclosure

Description Application Catalogue No.

Equipment Ground Bars

Aluminum PK27GTA

Copper PK27GTACU

Large Al Lug PK23GTAL

Insulator Kit PKGTAB

Plastic stick-on directory pouch 80031 15 901

Directory Cards 80031 15 801

Filler Plate (15 per package) NFFP15

Circuit Numbering Strips

Odd-Even 1-102 NF102OE

Sequential 1-102 NF102S

Odd-Even 103-204 NF204OE

Sequential 103-204 NF204S

Rail & Deadfront extensions

6” Extension NF6RDE

12” Extension NF12RDE

18” Extension NF18RDE

Branch Breaker Accessories

Standard AL lugs 15–30A (3 per kit) AL30FD

Standard AL lugs 35–110A (3 per kit) AL100FD

Optional Cu lugs 15–110A (3 per kit) CU100FD

Handle lockoff/padlock attachment HPAFD

Terminal nut insert kit (3 per kit) TIKFD

AL compression lug kit #8-1/0 AWG (3 lugs per kit) VC100FD

Cu compression lug kit #6-1/0 AWG (3 lugs per kit) CVC100FD

NF Standard Mechanical Lugs—Main Circuit Breaker

The lug range shown is for the highest amperage of the circuit breaker frame shown in the table.

Ampere Rating

Circuit Breaker Type Lug Wire Range

100 FI one #14–1/0 Cu or one #12–1/0 Al

125 ED,EG,EJ one #14–2/0 Al/Cu

150 HD, HG, HJ, HL one #14–3/0 Al/Cu

250 JD, JG, JJ, JL one 3/0–350 kcmil Al/Cu

250 KI one 1/0–350 kcmil Al/Cu

400 LA, LH one #1–600 kcmil or two #1–250 kcmil Al/Cu

600 LC, LI, LE, LX, LXI two 4/0–500 kcmil Al/Cu

Oversized Lugs for Neutral or Ground Bar

Lug Wire Range Catalogue No.

#10–#2 Al or #14–#4 Cu QO70AN

#4–#1/0 Al/Cu Q1100AN

#1–#4/0 Al/Cu Q1150AN

DE5_P15.fm Page 15 Wednesday, January 7, 2009 5:05 PM

Page 4: 8. Select accessories 7. Select branch circuit breakers .... Select accessories 7. Select branch circuit breakers ... ... Circuit

DE5-37

Panelboards

DE

5

PA

NE

LB

OA

RD

S

12/08

QMB

- Fusible Switch Type

.

Ground Bar Kits AI/Cu

MaximumAmp

Rating

Number of Terminals Aluminum - Al / Cu

No. ofCircuits (1) # 14 - # 4 Catalogue

Number

225 12 9 PK9GTA

225 20 12 PK12GTA

225 24 15 PK15GTA

225 30 18 PK18GTA

225 54 23 PK23GTA

600 54 27 + (1) # 6 - 2/0 PK27GTA

800 18 + (9) # 14 - 1/0 PK32DGTA

Isolating kit PKGTAB

Driphood Kits

TubDimensions

CatalogueNumber

15 W x 4.4 D DHK15

20 W x 5.75 D MHT2DH20

26 W x 6.5 D DHK26

32 W x 8.3 D DHK32

42 W x 9.5 D DHK42

35 W x 11.5 D DHK35

38 W x 11.5 D DHK38

Ground Bar Kits - Copper

MaximumAmpRatio

Max. No. of Circuits Catalogue Number

225 9 80103-026-50

225 12 80103-026-51

225 20 80103-026-52

225 25 80103-026-53

600 25 80103-026-54

Panel Accessories

Kit or Attachment For Panels Description Catalogue Number

Touch-upPaint

All Panels - 369G Aerosol can, present standard gray, ASA 49 PK49SP

All Panels - 450G Aerosol can, ASA 61 W469-X65

Joint Compound I-Line, QMB For use on plug-on connectors only when PJC-7201

breakers or units are removed and reinstalled.

Field Modification Kits and Accessories

DE5_P37.fm Page 37 Wednesday, January 7, 2009 5:21 PM