Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
FREEPHONE0800 389 9191
GENERATORSGENERATORSModels comply with EEC noise regulations
Hire
Service
ConstructionUtilitiesIndustrialTelecommunicationsEvent PowerCorporate
Prime PowerStandby PowerEmergency Power
All our generators are built and maintained to the higheststandard with the lowest soundlevels.
Our highly trained and experienced generator engineers and sales team combine to offer first class service and advice WHEREVERand WHENEVER you need it.
We have the knowledge andexpertise to service all yourgenerator hire requirements.
Combined with our fleet ofassociated equipment, we candeliver power WHEREVER andWHENEVER you need it.
SupportWe provide 24/7 technicalassistance and emergencyresponse with breakdowncover for our generators.
We also offer fuel managementproviding you with a total support package.
20kVA – 100kVA R/TSuper silenced set20kVA at 415/240vPerkins powered diesel engine50/60HZElectric start/RCD’sBunded tank
Super SilentRange 20kVA - 1000kVARoad Towable up to 100kVAComplete Service SupportExpert AdviceSite Surveys
Hire or SaleLong Running Tanks
45kVASuper silenced set45kVAPerkins powered diesel engine50/60HZElectric start/variable RCDBunded tank minimum 24 hourrunning
Secure Mini ContainerAverage noise level of 69dBADouble entry door c/w galvanised container door gearand SCM approvedVandal proof locking mechanism Emergency stop push buttonFuel fill and battery via lockablerear doors1350 litre fuel tank for 7 workingdays operation (8hrs per day)
500kVASuper silenced setPerkins powered dieselengine50/60HZBunded fuel tank minimum10hr @ 100% loadSynchronising panel connects multiple generators
500 kVA Generator
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk8484
13 Hire Depots - Serving South, West & North of England
13 Hire Depots - Serving South, West & North of England
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk 85
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk Telephone your nearest Hire Depot
GENERATORS
85
AUXILIARY TANKSAUXILIARY TANKS1000 – 4000 litres fully bunded fuel tanksCompliant with industry regulationsArmoured fuel hoses come with quick release couplingsfor easy connection to the generators
FUEL MANAGEMENTRegular fuel deliveries as and when required.
Distribution BoardsPlug in distribution boards 13A to 400ACEE form/Powerlock connectors with earth bond points
Lighting TOWERLIGHTSFlexible lighting for useon road works, construction, security,exhibitions and events.Tower lights are easy touse and mobile.
Transformers415V - 110V Transformers240V - 110V Transformers
Changeover(AMF) Panels
Plug in AMF panels to 125AHard wire AMF Panels 125A - 3200A
Cable
Cable Ramps
3PH & 1PH Cable CEE form Plugs & SocketsPowerlock and Lugged cable
920mm LengthsHeavy Duty Rubber Casing5 Channels
920mm lengths interlinking to formcontinuous ramped cable protection
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk8686
13 Hire Depots - Serving South, West & North of England
13 Hire Depots - Serving South, West & North of England
SUPER SILENCEDSUPER SILENCEDSuper Silenced Generator Technical Data
Option Available:– RT Road TowableSK Skid MountedSY Synchronisable Generators Available
* Weight information is a guide only, all weights given include a full integral fuel tank. Does not include trailer where fi tted.
Alternative generator models not listed above may be available and may be used without prior notification.
Rental Model
Prime Power
kVASize Kw
Amps/Phase @ 415v
Noise Level dBA@7m
Fuel Consumption at 100% Load
(Litres per hour)
Dimenions (Not Inc Trailer Where Fitted)
L x W x H
*WeightInc Fuel
(KG)
Options AvailableRT/SK/SY
BC14 13.6 11 45A@240v 58 4.3 1850 x 760 x 1200 754 RT/SKBC19 19 15 27 62 4.9 1948 x 835 x 1423 950 RT/SK
XD20 20 16 28 64 5.7 1684 x 900 x 1345 786 RT/SK
BC30 30 24 42 68 5.2 2242 x 900 x 1626 1245 RT/SK
XD30 30 24 42 62 7.4 2288 x 1130 x 1660 1830 SK
MG30 27 22 38 71 7.5 2000 x 900 x 1200 1136 RT
R33 30 24 42 75@1m 8.6 2200 x 1000 x 1528 1300 RT/SK
BC40 40 32 56 68 10.1 2242 x 900 x 1626 1285 RT/SK
R44 40 32 56 73@1m 10.4 2200 x 1000 x 1528 1350 RT/SK
XD45 45 36 56 67 13.5 2900 x 1130 x 1940 2405 SK
BC60 60 48 84 68 14.8 3035 x 1200 x 1800 2247 RT/SK
XD60 60 48 84 60 14.3 2900 x 1130 x 1940 2560 SK
MG70 63 50 88 65 14.3 3066 x 1000 x 1742 1890 RT
XD75 75 60 105 65 18.6 2900 x 1155 x 1940 2635 SK
XD80 80 64 112 66 18.1 3280 x 1130 x 2060 2819 SK
BC80 80 64 112 68 18.4 3035 x 1200 x 1800 2252 RT/SK
XD100 100 80 140 67 22 3280 x 1130 x 2060 2905 SK/SY
BC100 100 80 140 68 22 3035 x 1200 x 1800 2275 SK/SY
MG115 100 80 140 65 22 3200 x 1230 x 1870 2422 RT
R110 100 80 140 68 24.3 2860 x 1150 x 1995 2570 RT/SK
XD135 135 108 189 67 31 3570 x 1155 x 2030 3423 SK/SY
XD150 150 120 209 67 32 3558 x 1130 x 1943 3125 SK/SY
XD200 200 160 279 63 46 4150 x 1395 x 2140 4703 SK/SY
XD250 250 200 349 63 60 4150 x 1395 x 2140 4863 SK/SY
P350 350 280 489 69 76.3 4760 x 1620 x 2135 5137 SK/SY
XD400 400 320 559 66 80.1 5040 x 1800 x 2340 9060 SK/SY
P500 500 400 698 71 97.2 4990 x 1620 x 2140 6390 SK/SY
* Weight information is a guide only, all weights given include a full integral fuel tank. Does not include trailer where fitted.
A
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk 87
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk Telephone your nearest Hire Depot
GENERATORS
87
The Range forProfessional Rental Operators
Support Rest assured that we can also offer fuel management, emergency breakdown cover and technical assistance to provide you with the total support package.
Instant Power, the Generator Rental Division of Charles Wilson Engineers,offers extensive expertise and experience for all your power requirements onprojects of all sizes.
From small scale hiring to multiple machine packages, Instant Power canmeet your demands with our modern ‘up to date’ hire fleet of Super SilentDiesel Generators from 20kVA, Distribution Boards, Bunded Fuel Tanks, Cables, Transformers and Ancillaries.
Full product support from initial power assessment, fuel management, periodic maintenance and inspection through to 24 hour service backup ensures trouble free operation throughout the period of hire.
For products and services contact our national network.
Temporary Power Supplies
Short or Long Term Hire
Emergency Response
Power Management
Fuel Management
INSTANT POWER
Rental Specification
Robust steel, fully bunded, sound attenuated canopy.
Integral fuel tank with 3 way valves to connect to an auxiliary fuel tank.
Fuel/water separating filter, battery isolator, lube oil pump.
Radiator cleaning access. Central lifting point (recessed).
Door stays, document storage, lockable handles and cable gland plate.*
Separate control panel at end of set with all controls therein.
Power cubical at end of set with cable terminators andCEE form outlets.
Alternator protected for harsh environments and 100% humidity.
* Not applicable to model XD20
XD27Super silenced set and distribution
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk8888
13 Hire Depots - Serving South, West & North of England
13 Hire Depots - Serving South, West & North of England
This extremely lightweight inverter style generator is ideal forweight sensitive environments and suitable for running sensitive electrical equipment. Fitted with 230V 13a Socketsand 12 V DC terminals.
CODE No. 1 DAY WEEKEND WEEK
Technical Data
GEN-001 49.00 60.00 75.00
GENERATOR 2.7kVA/4.0kVA
Ideal for small power requirements such as power tools and sitelighting. Compact, lightweight and easily transportable. Will fitinto the boot of most vehicles. Runs on unleaded fuel.
CODE No. 1 DAY WEEKEND WEEK
Technical Data 2.7kVA
GEN-002 62.00 76.00 95.00
GEN-003 81.00 100.00 125.00
Technical Data 4.0kVA
GENERATOR 5.9kVA
GENERATOR 1.7kVA
This silenced electric start diesel/petrol powered generator is verylight and compact in its class. An integral 24 ltr fuel tank gives 13 hours running at full load and also has low fuel shutdownengine protection. Fitted with multiple industrial socket outlets.
CODE No. WEEK
Technical Data
GEN-006D Diesel POAGEN-006P Petrol POA
PORTABLE SILENT DIESEL
(IT SENSITIVE)
HOW TO CALCULATE THE SIZE OF GENERATOR REQUIRED1. See appliance rating to find the Volts, Amps and Power Factor.2. Use the following formula to calculate generator required:
KVA = Volts x Amps
x Power Factor1000
Size 1.7 kVARating 1.5 kwRunning time at 100% load 7hrs
Fuel PetrolWeight 21kg Size 2.7 kVA
Rating 2.2 kwRunning time at 100% load 2.8 hrs
Fuel PetrolWeight 36kg
Size 4.0 kVARating 3.2 kwRunning time at 100% load 3.4 hrs
Fuel PetrolWeight 59kg
Size 5.9 kVARating 4.7 kwRunning time at 100% load 13 hrs
Fuel Diesel/PetrolWeight 159kg
Height 885mmWidth 1120mmDepth 735mm
db(a)db(a)@ 7 metres
67.0
db(a)db(a)71
db(a)db(a)73
@ 7 metres
@ 7 metres
GENERATOR 10.0 kVA
With noise levels as low as 60dBA, this range is suitable for usein extreme ‘noise sensitive’ environments. These compact generators are fully enclosed in weather-proof acoustic canopieswith long range bunded fuel tank and are among the quietestmachines available.
CODE No. WEEK
Technical Data
GEN-SS010 POA
ELECTRIC START
Size 11 kVAFuel Capacity 120 ltrsRunning time at 100% load 38 hrs
Fuel DieselWeight 607kg
db(a)db(a)60
@ 7 metres
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk 89
INSTANT TOOL HIRE FOR ALL INDUSTRY – www.cwplant.co.uk
Telephone your nearest Hire Depot
GENERATORS
89
BOWSERSBOWSERSMOBILE FUEL BUND
With effect from 10th May 2004 all tanks, various sizes available,used on road transport must comply with ADR requirements.Charles Wilson Engineers’ range are built to (IBC) intermediatebulk container standards with unique ease of maintenance features including removable inner tank (on transcubes) andinspection chambers.
Health & SafetySuitable for bulk storage of diesel on site under currentenvironmental requirements. Complies fully with BS 799
part type 111/j and ppg 2 (transport empty only).
STATIC FUEL STORAGE TANK
Transportable fuel tank. ADR approved as an IBC fortransport of diesel fuel according to UN requirements.Double walled/bunded for environmental compliancePPG2 (Pollution Prevention Guidelines).Capacity - 950 litres/209 galls.Dimensions - 3475mmL x 1550mmW x 1700mmH
11.4' L x 5.1' W x 5.6' H
Range of drip trays forcompliance with “The Control ofPollution (Oil storage)(England) 2001”.Forklift pockets to facilitate handling. Removable mesh floorfor easy cleaning.Available in a range of sizes in both galvanised and moulded polythene.
Double walled/bunded for environmental compliancePPG2 (Pollution Prevention Guidelines).Built to a standard of BS799 Part 5 for strength and durability.Available from 450-4500 litres capacity.
100-1000 galls.Drip tray for compliance with “The Control of Pollution(Oil storage) (England) 2001”.Can be placed under plant being refuelled, any spillageis captured in the sump and wheeled to safety. Forklift pockets to facilitate handling.Robust construction and easy to handle.
TRANSPORTABLE FUEL TANK
DRUM BUNDS
ENVIROBASIN WHEELED DRIP TRAY
WATER
BOWSERS
TURN TO
PAGE 118
WATER
BOWSERS
TURN TO
PAGE 118
CODE No. BOW - TRL2 WEEK POACODE No. BOW - TRL5 WEEK POA
CODE No. BOW-DRIP WEEK POA
CODE No. BOW-BUND WEEK POA