12
HAMILTON-H900 Intelligent humidification HAMILTON-H900

689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

HAMILTON-H900Intelligent humidification

HAMILTON-H900

Page 2: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

2

Page 3: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers with technologies that allow them to focus on the important aspects of patient care. When we developed the HAMILTON-H900 humidifi er, we talked to many clinicians to understand what they would improve in conventional humidification. Easier handling of circuits, cables and connections, improved user interfacing, reduction of rain-out, and increased safety were the most requested enhancements. With the HAMILTON-H900, we aim at improving humidifi cation in exactly these areas.

Intelligent humidifi cation

Our intention was to develop an advanced

humidifi er that is ergonomic and intuitive to use

and increases the effi ciency in ventilation care.

Jens HallekPresidentHamilton Medical

Hamilton Medical | HAMILTON-H900 3

Page 4: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

1

2 34

5

67

8

9

10

12

8

4

Page 5: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

11

Product overview

Expiratory hose temperature control

Auto mode

Manual temperature control

Invasive / noninvasive mode

Relative humidity control (temp. gradient)

All-in-one connector

Temperature display control

Tube connection indicator

Visual alarm indicator

Optical water level detection

Smooth-bore wall-heated circuit

Integrated temperature probe

1

2

4

5

6

7

8

9

10

11

12

3

Hamilton Medical | HAMILTON-H900 5

Page 6: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

Increased safety

Less risk of cross contamination

By reducing the need to open the circuit to drain condensate, the HAMILTON-H900 minimizes the potential for the spread of pathogens associ-ated with the development of ventilator-associated pneumonia (VAP).

Automatic connection check

The HAMILTON-H900 automatically and individually checks the circuit connections and alerts you when a tube is not correctly connected. Ar-rows light up to indicate which tube needs to be reconnected. Chamber and circuit types are also automatically detected.

Intuitive alarm messages

The alarms are very visible using self-explanatory on-screen icons on the clear LCD display.

Automatic water level detection

The HAMILTON-H900 detects high and low water levels and alarms well ahead of time, before the chamber is empty. Preventing the patient from being ventilated without humidification optimally protects the functionality of mucociliary clearance.

Adjustable temperature and humidity settings

As every patient is different and environmental conditions may require important modifications, the HAMILTON-H900 humidifier allows for manual adjustment of temperature and humidity settings (temperature gradient). This allows you to perfectly adapt the humidification therapy to the individual patient and environmental conditions. You can easily avoid having too much condensation in the tubing, flow sensor, or flex tube by adjusting the relative humidity level.

6

Page 7: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

Ergonomic and intuitive user interface

Due to the ergonomic design, the user interface can be easily seen and operated from a standing position, and provides all the information you need at a glance. All settings and related monitoring values are visible without searching through menus. A large LCD display, bright alarm lamp, and audible alarm alert you in the event of a required user interaction. The high-contrast LCD display provides excellent readability, even in direct sunlight.

Intuitive to operate

Current chamber exit temperature

Current temperature settings

Current relative humidity settings

COM connectivity symbol

Minimum possible temperature

Maximum possible temperature

Selected mode

1

2

3

4

5

6

7

1

2

3

4

5 6

7

Hamilton Medical | HAMILTON-H900 7

Page 8: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

Pre-assembled and ready to use

An innovation of the HAMILTON-H900 is that it comprises only two components, which are delivered pre-assembled and ready to use: The pre-assembled wall-heated breathing set including all-in-one connectors, temperature probe, water refill tube, Y-piece, and water chamber, and the humidifier base with the user interface and the heating plate. This saves time, increases efficiency, and facilitates the handling of the humidifier, as well as reducing the risk of contamination.

One-hand operation

The unique combination of having all connections on a humidifier in one single breathing set provides the highest level of ergonomics. Operate the humidifier, change breathing circuits, and replace the water chamber with just one hand. With no need to worry about extra cables to connect or disconnect anymore, you only need to slide the water chamber into the humidifier and connect the breathing circuit to the patient.

Easy to handle

Humidifier station with breathing set including temperature probe, wall-heated breathing circuit, water refill tube, Y-piece, and water chamber

One-hand operation and enhanced ergonomics

8

Page 9: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

Remote control from the ventilator

The unique ventilator connectivity option allows control of the humidifier from any compatible ventilator. All controls, monitoring parameters, and alarms are available and can be controlled from the ventilator. Full integration of humidifier monitoring into patient data management systems is also provided.

Together with a compatible ventilator, the humidifier can automatically select the humidification mode (invasive vs. noninvasive) based on the selected ventilation mode.

An integrated solution

Hamilton Medical | HAMILTON-H900 9

Page 10: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

Advanced breathing sets

Thermal image of conventional circuits with inlet heating coil Thermal image of HAMILTON-H900 circuit

Fewer connections, less troubles

With the HAMILTON-H900’s advanced breathing circuits with integrated temperature probe, disconnected cables, losing temperature probes, and leaking temperature ports are now a thing of the past.

Color-coded circuits

To support an accurate and safe circuit setup, the circuit tubes are color coded: blue inspiratory limb and white expiratory limb.

Low compliance and flow resistance

With decreased flow resistance and low compliance, the breathing sets offer optimal ventilation properties for all applications by ensuring that the set tidal volume and pressure are delivered to the patient. Essential features - especially for infants.

Wall-heated, all-in one breathing circuits

Both limbs of the pre-mounted set integrate the heater wires into the circuit wall. This eliminates the cold interface between heated breathing gas and ambient temperatures and leads to significantly reduced conden-sation and rain-out effects in the breathing circuit. Thereby ensuring the delivery of the set level of humidity to the patient.

10

Page 11: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

For all patients

Single-use breathing sets

The pre-mounted breathing sets can be used up to 28 days for patients over 10 kg, and include a temperature probe, water refill tube, Y-piece, and water chamber. The sets are available with dual limbs or a single limb.

The Hamilton Medical infant breathing sets are specially designed for even your smallest patients up to 15 kg. The detachable, unheated ex-tension allows for use in incubators.

As the respiratory system of neonatal patients is not fully developed or is at least very sensitive, the HAMILTON-H900 humidifier allows for manual adjustment of temperature and humidity settings. You can perfectly adapt the humidification settings to the special needs of your small patients and environmental conditions.

Autoclavable breathing sets

The reusable breathing sets offer the same unique design, using a wall-heated inspiratory limb only.

Reduced cost of ownership

Over the lifetime of a humidifier, the initial investments are relatively small. Cost-driving factors include circuits, cables, and temperature probes. With the HAMILTON-H900, expensive replacements for lost or broken temperature probes and cables are a thing of the past. Due to reduced risk of cross contamination, a long life span and high-quality materials, the HAMILTON-H900 single-use breathing set can be used for up to four weeks on a patient.

Hamilton Medical | HAMILTON-H900 11

Page 12: 689504.01 HAM-H900 BROCHURE EN - ESICM · Humidifi cation is an important part of respiratory care. As a manufacturer of ventilation solutions, our vision is to provide caregivers

Hamilton Medical AGVia Crusch 8, 7402 Bonaduz, Switzerland +41 58 610 10 [email protected]

Hamilton Medical

Intelligent Ventilation since 1983

In 1983 Hamilton Medical was founded with a vision: To develop intelligent ventilation solutions that make life easier for patients in critical care and for the people who care for them. Today, Hamilton Medical is a leading manufacturer of critical care ventilation solutions for a variety of patient populations, applications, and environ-ments.

6895

04/01

Sp

ecifi

cati

on

s ar

e su

bje

ct t

o c

han

ge

wit

ho

ut

no

tice

. © 2

015

Ham

ilto

n M

edic

al A

G. A

ll ri

gh

ts r

eser

ved

.