10

64 - ShipServ · Cables Pg 4 CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

  • Upload
    ngodieu

  • View
    256

  • Download
    3

Embed Size (px)

Citation preview

Page 1: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7
Page 2: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7
Page 3: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

TFKable Shipboard Cables Prsymian Shipboard Cables SEC Shipboard Cables Nexans Shipboard Cables Unika FPSO Cables NEK606 Offshore Cable Industrial Cables Data and Antenna Cables 

Cables Contents ‐ Pg 4 & 5 

Search Lights Flood Lights Navigation Lights Watertight Fluorescent Ceiling Lights Non‐Watertight Fluorescent Ceiling Lights Mirror Lights Berth Lights Corner Lights Desk Lights Chart Table Lights Down Lights Decorative Wall Lights Watertight Incandescent Lights Portable Hand Lamps 

Lightings Contents ‐ Pg 28 

ATEX Fluorescent Lights Ex‐Proof Incandescent Lights ATEX Flood Lights Helideck Equipments ATEX Sounders/Beacons Ex‐Proof Wiring Devices Ex‐Proof Junction/Joint Box Flash Lights Pneumatic Lights Ex‐Proof Cable Glands Ex‐Proof Enclosure 

Equipments for Hazardous Areas Contents ‐ Pg 42 

Cable Glands Junction Boxes/Enclosures Terminal Strips/Blocks/Mounting Rails Cable Markers/Marker Strips Cable Ties/Marker Straps Band Straps/Buckles/Tools Sealing Compounds Cable Ladder/Tray Tubes/Sleeves Cable Terminals/Ferrules Tools & Accessories ‐ Cable Terminals Cable Markers Cable Clips/Clamps/Saddles Insulation Materials Soldering Tools/Accessories Insulation Tapes Cable Carrier 

Cable Accessories Contents ‐ Pg 64 

Ballasts Ignitor Capacitor Starter Fluorescent Lamp Holders Starter Holder/Terminal Block Lamp Holders Search Light Holder Navigation Light Lamp Holder Halogen Lamp Holder Glass Globes/Guards 

Lighting Components Contents ‐ Pg 88 

Rough Service Lamps Standard Lamps Emergency Battery Lamps Rough Service/Standard Lamp E‐40 Colour Lamp Navigation Lamps Compass/Signal/Smoke Detector/Buoy Lamp Miniature/Pilot Lamps Sealed Beam Lamps Reflector Lamps HID Lamps Xenon Lamp Halogen Lamps Flash light Bulbs Search Light Lamps Fluorescent Lamps Compact Energy Saving Lamps Architectural/Striplite Lamp 

Lamps Contents ‐ Pg 95 

AC/DC Adaptor Measuring Instruments Batteries/Batteries Accessories Flashlights Aerosols Portable Ventilation Fan/Blower Hot Air Gun/Fan Heater I.T Hardware & Software 

Other Products Contents ‐ Pg 138 

Fuses Relays Timers Transformer Power Supply Hour Counter Mastervolt Ventilation Fan Schneider ABB Terasaki 

Switchboard Control & Automation Contents ‐ Pg 116 

Extension Cable Reel/Socket Distribution Box Wonpro 

Mennekes Gewiss Sanshin Wiska PDL Switches Wiring Accessories 

Wiring Devices Contents ‐ Pg 52 

Ship Horn Alarm Equipments 

Ship Horn & Alarm Equipment Contents ‐ Pg 38 

BH Global Marine Limited is a supply chain management company

specialising in premium lightings, cables and electrical equipments.

We provide one stop solution for electrical supplies for marine offshore, oil & gas

industries.

Page 4: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

Cables

Pg 4

www.bhglobal.com.sg

CABLES CONTENTSCABLES CONTENTS TFKable Shipboard Cables

NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7 NTKOXSekw 150/250(300V) - Page 7 NTKOXSekf/ekw 150/250V - Page 7 NKOXS 0.6/1 kV - Page 7 - 8 KONS 0.6/1 kV - Page 8 NKOGSekw 0.6/1 kV - Page 8 NTKOGSekw 150/250V - Page 8 - 9 MVEPRHXCuHX 8.7/15kV - Page 9

Prysmian Shipboard Cables HFX-A/Cu 0.6/1kV - Page 9 HFX-OSA/Cu 250V - Page 9 HFX-ISOSA/Cu 250V - Page 10 HFX-A/Cu-FR 0.6/1kV - Page 10 HFX-OSA/Cu-FR 250V - Page 10 HFX-ISOSA/Cu-FR 250V - Page 10 - 11

SEC Shipboard Cables HF-CXO 0.6/1 kV - Page 11 HF-CXOSA 0.6/1kV - Page 11 - 12 HF-IXOSA 150/250V - Page 12 HF-IXO(I)SA 150/250V - Page 12 - 13 HFF-CX 06/1kV - Page 13 FRHF-CXOSA 06/1kV - Page 13 - 14 FRHF-IXOSA 150/250V - Page 14 FRHF-IXO(I)SA 150/250V - Page 14 HF-CXOSA 6/10kV - Page 14

Nexans Shipboard Cables MPRX 0.6/1kV - Page 15 MPRXCX 250V, 0.6/1kV - Page 15 MPRXCX-FLEX 0.6/1kV - Page 15 TCX(C) 150/250V - Page 15 - 16

TCX(I) 150/250V - Page 16 MPRXCX 331 250V, 0.6/1kV - Page 16 TCX(C) 331 150/250V - Page 16 - 17 TCX(I) 331 150/250V - Page 17

Unika FPSO Cables U-HF m 0.6/1 kV - Page 17 U-HFA m 0.6/1 kV - Page 17 - 18 U-HFAT m (C) 250V - Page 18 U-HFAT m (I) 250V - Page 18 U-HFAT m (I+C) 250V - Page 18 - 19 U-HFFRA m 0.6/1 kV - Page 19 U-HFFRAT m (C) 250V - Page 19 U-HFFRAT m (I+C) 250V - Page 19 - 20 U-HFA m EMC 0.6/1 kV - Page 20 U-HFA m VFD 1.8/3 kV - Page 20

NEK606 Offshore Cables P1/P8 RFOU 0.6/1kV - Page 20 - 21 S1/S5 RFOU(I) 150/250V - Page 21 P5/P12 BFOU 0.6/1kV - Page 21 - 22 S3/S7 BFOU(I) 150/250V - Page 22 - 23

Industrial Cables H07RN-F 450/750V - Page 23 - 24 H05RN-F 300/500V - Page 24 H05V-K 300/500V - Page 24 H07V-K 450/750V - Page 24 H05VV-F 300/500V - Page 25 VCTF 300/500V - Page 25 VCTFB 300/500V - Page 25 S1HF 300/500V - Page 25 SGW - Page 25 WCT Welding Cable - Page 26 H01N2-D Welding Cable - Page 26

Page 5: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

Cables ORDERLINE +65 6291 4444

Marine and Offshore Electrical Supply Pg 5

CABLES CONTENTSCABLES CONTENTS Industrial Cables

NSHTOU 0.6/1kV - Page 26

Data and Antenna Cables RG - Coaxial Cable - Page 26 Class Approval Coaxial Cable - Page 26 Class Approval CAT 7 Lan Cable - Page 26 Class Approval Can Bus Cable - Page 26 Class Approval AS-Interface Cable - Page 26 - 27 Class Approval Profibus Cable - Page 27

Page 6: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

Cables

Pg 6

www.bhglobal.com.sg

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables            (kg/km) 

BH Code   

1 x 1.5  6.3  7.7  76  A1021001   

1 x 2.5  6.7  8.2  89  A1021002    

1 x 4  7.4  9  115  A1021004    

1 x 6  7.9  9.6  138  A1021006    

1 x 10  8.7  10.5  186  A1021010    

1 x 16  10  12  265  A1021016    

1 x 25  11.5  14  384  A1021025    

1 x 35  13  16  526  A1021035    

1 x 50  14.5  17.5  677  A1021050    

1 x 70  16.5  20  918  A1021070    

1 x 95  18.5  22.5  1205  A1021095    

1 x 120  20  24.5  1459  A1021120    

1 x 150  22.5  26.5  1787  A1021150    

1 x 185  25  29.5  2217  A1021185    

 1 x 240  27.5  32.5  2818  A1021240    

1 x 300  30  35.5  3446  A1021300    

2 x 1  8.8  10.5  131  A1022000    

2 x 1.5  9.3  11.5  154  A1022001    

2 x 2.5  10  12.5  191  A1022002    

2 x 4  11  13.5  242  A1022004    

2 x 6  13  15.5  346  A1022006    

2 x 10  14.5  17.5  475  A1022010    

2 x 16  16.5  20  671  A1022016    

2 x 25  20  24  987  A1022025    

2 x 35  22.5  27  1259  A1022035    

2 x 50  25.5  30.5  1641  A1022050    

3 x 1  9.2  11  144  A1023000    

3 x 1.5  10  12  177  A1023001    

3 x 2.5  10.5  13  222  A1023002    

3 x 4  11.5  14.5  289  A1023004    

3 x 6  13.5  16.5  403  A1023006    

3 x 10  15.5  19  573  A1023010    

3 x 16  17.5  21  817  A1023016    

3 x 25  21.5  26  1245  A1023025    

3 x 35  24  28.5  1606  A1023035    

3 x 50  27  32.5  2119  A1023050    

3 x 70  31.5  37.5  2911  A1023070    

3 x 95  36  43  3963  A1023095    

3 x 120  40  47.5  4916  A1023120    

3 x 150  45  53  6120  A1023150    

3 x 185  50  59  7524  A1023185    

3 x 240  56  66  9640  A1023240    

4 x 1  10  12  171  A1024000    

4 x 1.5  10.5  13  203  A1024001   

4 x 2.5  11.5  14  259  A1024002   

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

4 x 4  13.5  16  375  A1024004   

4 x 6  14.5  17.5  486  A1024006   

4 x 10  17.5  20.5  696  A1024010    

4 x 16  19.5  23  1010  A1024016    

4 x 25  23.5  28.5  1546  A1024025    

4 x 35  26.5  31.5  2000  A1024035    

4 x 50  30  35.5  2648  A1024050    

4 x 70  35  42  3764  A1024070    

4 x 95  40.5  48.5  5105  A1024095    

4 x 120  45  53.5  6309  A1024120    

5 x 1  10.5  13  197  A1025000    

5 x 1.5  11.5  14  237  A1025001    

5 x 2.5  13  15.5  341  A1025002    

5 x 4  15.5  18.5  491  A1025004    

5 x 6  17  20.5  636  A1025006    

5 x 10  19.5  23.5  898  A1025010    

5 x 16  22.5  26.5  1294  A1025016    

5 x 25  26.5  232  1940  A1025025    

5 x 35  30  35.5  2517  A1025035    

7 x 1  11.5  14  232  A1026070    

7 x 1.5  13  15.5  320  A1026071    

7 x 2.5  14  17  419  A1026072    

8 x 1.5  14.5  17  370  A1026081    

9 x 1  ‐  ‐  ‐  A1026090    

9 x 1.5  15.5  18.5  415  A1026091    

10 x 1  14.5  17.5  369  A1026100    

10 x 1.5  16  19  442  A1026101    

10 x 2.5  17.5  21  588  A1026102   

12 x 1  15  18  403  A1026120    

12 x 1.5  16.5  19.5  496  A1026121    

12 x 2.5  18  21.5  644  A1026122    

16 x 1  16.5  20  489  A1026160    

16 x 1.5  18  21.5  595  A1026161    

16 x 2.5  20  23.5  793  A1026162    

19 x 1  17..5  20.5  533  A1026190    

19 x 1.5  19  22.5  672  A1026191    

19 x 2.5  21  25  909  A1026192    

20 x 1.5  20  23.5  706  A1026201    

24 x 1  20  23.5  658  A1026240    

24 x 1.5  22  26  830  A1026241    

24 x 2.5  24.5  29  1134  A1026242    

27 x 1  20.5  24.5  709  A1026270    

27 x 1.5  22.5  26.5  886  A1026271    

30 x 1.5  23.5  27.5  977  A1026301    

37 x 1  23  27  881  A1026370    

37 x 1.5  25  29.5  1131  A1026371    

TFKable Shipboard Cables

NKOXSekw 0.6/1kV 

NKOXSekw FLEX 0.6/1kV 

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

1 x 185  26  31  2113  A1021186   

Test Performances Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>=4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Bureau Veritas - Lloyd’s Register - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping

Application Fixed Installations in all areas and open deck Copper wire braiding provides shielding against EMI

Halogen Free Low Smoke Power Cables, with Copper Wire Braiding

Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>=4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping

Application Fixed Installations in all areas and open deck Copper wire braiding provides shielding against EMI

Halogen Free Low Smoke Power Cables, with Copper Wire Braiding, Class 5 Conductors

Page 7: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

Cables ORDERLINE +65 6291 4444

Marine and Offshore Electrical Supply Pg 7

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

1 x 240  29  24.5  2669  A1021241   

1 x 300  31.5  37.5  3290  A1021301   

3 x 50  29.5  35  2120  A1023051   

3 x 70  33  40  2880  A1023071    

3 x 95  38  45.5  3816  A1023096    

3 x 120  42  50  4732  A1023121    

3 x 150  47.5  56.5  5969  A1023151    

3 x 185  52  62  7269  A1023186    

3 x 240  59  69.5  9125  A1023241    

4 x 50  32.5  38.5  2663  A1024051    

4 x70  37  45  3739  A1024071    

4 x 95  43  51.5  4930  A1024096    

4 x 120  47.5  56.5  6092  A1024121    

4 x 150  52.5  62.5  7522  A1024151    

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

60V 0.5mm2   1 x 2 x 0.5  6.3  7.8  74  A1030120   

1 x 4 x 0.5  6.9  8.6  97  A1030140    

2 x 2 x 0.5  8.6  10.5  114  A1030220    

4 x 2 x 0.5  9.6  11.5  154  A1030420    

7 x 2 x 0.5  11  13.5  222  A1030720    

10 x 2 x 0.5  14.5  17.5  341  A1031020    

14 x 2 x 0.5  15.5  18.5  419  A1031420    

19 x 2 x 0.5  17.5  20.5  505  A1031920    

24 x 2 x 0.5  20  24  638  A1032400    

37 x 2 x 0.5  23  27  868  A1033700    

250V 0.75mm2   1 x 2 x 0.75  7.1  8.8  91  A1030121   

1 x 3 x 0.75  7.5  9.2  102  A1030131   

1 x 4 x 0.75  8  9.8  121  A1030141   

2 x 2 x 0.75  10  12  140  A1030221   

4 x 2 x 0.75  12.5  14  208  A1030421   

7 x 2 x 0.75  13.5  16.5  286  A1030721   

10 x 2 x 0.75  17.5  21  448  A1031021   

14 x 2 x 0.75  19  22.5  552  A1031421   

19 x 2 x 0.75  21  25  692  A1031921   

24 x 2 x 0.75  24.5  29  855  A1032421   

37 x 2 x 0.75  28.5  33.5  1188  A1033701   

1 x 2 x 1.5  8.2  10.1  123  A1030122   

1 x 3 x 1.5  8.8  11  148  A1030132   

1 x 4 x 1.5  9.5  11.5  176  A1030142   

2 x 2 x 1.5  12   14.5  208  A1030222   

4 x 2 x 1.5  14  17  355  A1030422   

7 x 2 x 1.5  17  20.5  508  A1030722   

10 x 2 x 1.5  21.5  25.5  699  A1031022   

14 x 2 x 1.5  23  26.5  788  A1031422   

19 x 2 x 1.5  26  30.5  1139  A1031922   

24 x 2 x 1.5  30.5  36  1421  A1032402   

37 x 2 x 1.5  35  41.5  1998  A1033702   

250V 1.5mm2  

NTKOXSekw 150/250 (300V) 

Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>=4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-376 Materials : IEC 60092-351, IEC 60092-359

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Bureau Veritas - Lloyd’s Register - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping

Application Interconnection of all sorts of instrumentation and communication equipment Copper wire braiding provides shielding against EMI

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net         Weight of Cables (kg/km) 

BH code   

1 x 2 x 0.75  9.3  11  149  A1040121   

1 x 3 x 0.75  9.6  11.5  163  A1040131    

2 x 2 x 0.75  12.5  15  254  A1040221   

4 x 2 x 0.75  14  17  339  A1040421    

7 x 2 x 0.75  17  20.5  510  A1040721    

10 x 2 x 0.75  21  24.5  694  A1041021    

14 x 2 x 0.75  22.5  26.5  857  A1041421    

19 x 2 x 0.75  25  29.5  1061  A1041921    

24 x 2 x 0.75  28.5  33.5  1299  A1042421    

37 x 2 x 0.75  32.5  38  1744   A1043721    

2 x 2 x 1.5  14.5  17.5  344  A1040222    

4 x 2 x 1.5  17  20.5  539  A1040422    

7 x 2 x 1.5  20  24  744  A1040722    

10 x 2 x 1.5  25  29.5  1041  A1041022   

Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-376 Materials : IEC 60092-351, IEC 60092-359

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping

Application Interconnection of all sorts of instrumentation and communication equipment Copper wire braiding provides shielding against EMI

Halogen Free Low Smoke Instrumentation Control and Telecommunication Cables, Individual Pair Screen with Copper Wire Braiding.

NTKOXSekf/ekw 150/250 (300V) 

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net     Weight of Cables (kg/km) 

BH Code   

1 x 1.5  4.7  5.8  38  A1010011   

1 x 2.5  5  6.3  49  A1010021    

1 x 4  5.4  6.9  66  A1010041    

1 x 6  6  7.5  87  A1010061    

1 x 10  7  8.7  132  A1010101    

1 x 16  7.9  9.8  198  A1010168    

1 x 25  9.7  12  306  A1010258    

1 x 35  10.5  13  400  A1010358    

1 x 50  12  15  536  A1010508    

1 x 70  14  17  747  A1010708    

1 x 95  16  19.5  1010  A1010958    

1 x 120  17.5  21.5  1259  A1011208    

1 x 150  19.5  23.5  1542  A1011508    

1 x 300  27  32  3077  A1013008    

2 x 1.5  8.3  10.5  116  A1012001    

2 x 2.5  9.1  11  149  A1012002    

2 x 4  10  12.5  201  A1012004    

NKOXS 0.6/1 kV 

Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping

Application Fixed installations in all areas in ships

Halogen Free Low Smoke Power Cables

Halogen Free Low Smoke Instrumentation Control and Telecommunication Cables, Overall Screen with Copper Wire Braiding.

Page 8: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

Cables

Pg 8

www.bhglobal.com.sg

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

3 x 1.5  8.8  11  133  A1013001    

3 x 2.5  9.8  12  179  A1013002    

3 x 4  10.5  13  239  A1013004    

3 x 6  12  14.5  315  A1013006    

4 x 1.5  9.7  12  160  A1014001    

4 x 2.5  10.5  13  213  A1014002    

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net     Weight of Cables (kg/km) 

BH Code   

1 x 0.75  2.4  3.1  13  A1080001   

1 x 1  2.4  3.2  15  A1080011    

1 x 1.5  2.7  3.5  19  A1080021    

1 x 2.5  3.1  4  30  A1080031    

1 x 4  3.6  4.6  44  A1080041    

1 x 6  4.2  5.2  62  A1080061    

1 x 10  5.2  6.6  105  A1080101    

1 x 16  6.2  7.8  159  A1080161    

1 x 25  7.6  9.6  245  A1080251    

1 x 35  9  11.5  332  A1080351    

1 x 50  10.5  13.5  479  A1080501    

1 x 70  12  15.5  664  A1080701    

1 x 95  14  17.5  879  A1080951    

1 x 120  15.5  19.5  1104  A1081201    

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

1 x 25  13  15.5  431  A1121025   

1 x 35  14.5  17.5  587  A1121035    

1 x 50  16.5  19.5  756  A1121050    

1 x 70  18  21.5  979  A1121070    

1 x 95  20  24  1288  A1121095    

1 x 120  22  26  1558  A1121120    

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cable (kg/km) 

BH Code   

1 x 150  23.5  28  1859  A1121150   

1 x 300  31.5  37  3496  A1121300   

2 x 1.5  11  13.5  220  A1122000   

2 x 2.5  12  14.5  267  A1122002    

2 x 4  13.5  16  373  A1122004    

2 x 6  14.5  17.5  423  A1122006    

2 x 10  16.5  19.5  569  A1122010    

2 x 16  18.5  22  759  A1122016    

2 x 25  22.5  26.5  11110  A1122025    

2 x 35  24.5  29  1382  A1122035   

2 x 50  27.5  33  1827  A1122050   

3 x 1.5  11.5  14  245  A1123000    

3 x 2.5  13  16  353  A1123002    

3 x 4  14  17  418  A1123004    

3 x 6  15.5  18.5  512  A1123006    

3 x 10  17.5  20.5  686  A1123010    

3 x 16  19.5  23.5  926  A1123016    

3 x 25  23.5  28  1353  A1123025    

3 x 35  26  31  1728  A1123035    

3 x 50  29.5  35  2270  A1123050    

3 x 70  33.5  40  3020  A1123070    

3 x 95  39  46.5  4193  A1123095    

3 x 120  42  50  5069  A1123120    

3 x 150  47  55  6195  A1123150    

3 x 185  51.5  61  7562  A1123186    

4 x 1.5  13  16  339  A1124001    

4 x 2.5  14  17  396  A1124002    

4 x 4  15.5  18.5  504  A1124004    

4 x 6  17  20  591  A1124006    

4 x 10  19  22.5  815  A1124010   

5 x 1.5  14  17  380  A1125001    

5 x 2.5  15.5  18.5  478  A1125002    

7 x 1.5  15  18  450  A1126071    

7 x 2.5  16.5  19.5  550  A1126072    

9 x 1.5   18.5   21.5   570  A1126091    

10 x 1.5  19  22  610  A1126101    

12 x 1.5  19.5  23  677  A1126121    

12 x 2.5  21  25  860  A1126122    

16 x 1.5  21.5  25  828  A1126161    

16 x 2.5  23.5  27.5  1049  A1126162    

19 x 1.5  22.5  26.5  904  A1126191    

24 x 1.5  26.5  30.5  1140  A1126241    

24 x 2.5  28.5  33.5  1478  A1126242    

30 x 1.5  27.5  32  1323  A1126301    

37 x 1.5  30  34.5  1529  A1126371    

Test Performance Flame Retardant : IEC 60332-1-2 Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-354 Materials : IEC 60092-351, IEC 60092-359

Application Fixed wiring in switchboards, control panels and other enclosures

Halogen Free Low Smoke Switchboard Wire

KONS 0.6/1 kV 

NKOGsekw 0.6/1 kV 

Test Performance Fire Resistant : IEC 60331-21 : 3h, 950oC Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 : transmittance values > 70% Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359

Application Fire resistant cables for fixed installations in all areas and open deck Copper wire braiding provides shielding against EMI

Halogen Free Low Smoke Fire Resistant Power Cables with Copper Wire Braiding

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables  (kg/km) 

BH Code   

1 x 2 x 0.75  7.1  8.8  91  A1130121    

1 x 4 x 0.75  8  9.8  121  A1130141    

2 x 2 x 0.75  10.5  13  175  A1130221    

250V 0.75mm2  

NTKOGsekw 150/250V (300V) 

Test Performance Fire Resistant : IEC 60331-21 : 3h, 950oC Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 : transmittance values > 70% Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-376 Materials : IEC 60092-351, IEC 60092-359

Application Fire resistant cables, interconnection of all sorts of instrumentation and communication equipment Copper wire braiding provides shielding against EMI

Halogen Free Low Smoke Fire Resistant Instrumentation Control and Telecommunication Cables, Overall Screen with Copper Wire Braiding.

Type Approval Certificates - Det Norske Veritas

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping

Page 9: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

Cables ORDERLINE +65 6291 4444

Marine and Offshore Electrical Supply Pg 9

Prysmian Shipboard Cables

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net     Weight of Cables 

(kg/km) BH Code   

3 x 35  49.5  54.5  4438  A1433035   

3 x 70  56  61.5  6175  A1433070    

3 x 95  59.5  65.5  7325  A1433095    

3 x 150  66.5  73.5  9744  A1433150    

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net     Weight of Cables (kg/km) 

BH Code   

4 x 2 x 0.75  11.5  14  208  A1130421   

7 x 2 x 0.75  13.5  16.5  286  A1130721   

10 x 2 x 0.75  17.5  21  448  A1131021    

14 x 2 x 0.75  19  22.5  552  A1131421    

19 x 2 x 0.75  21  25  692  A1131921    

24 x 2 x 0.75  24.5  29  855  A1132421    

37 x 2 x 0.75  28.5  33.5  1188  A1133721    

1 x 2 x 1.5  8.2  10.1  123  A1130122   

2 x 2 x 1.5  12.5  15  258  A1130222   

4 x 2 x 1.5  14  17  355  A1130422   

7 x 2 x 1.5  17  20.5  508  A1130722   

10 x 2 x1.5  21.5  25.5  699  A1131022   

14 x 2 x 1.5  23  27.5  896  A1131422   

19 x 2 x 1.5  26  30.5  1139  A1131922   

250V 1.5mm2  

MVEPRHXCuHX 8.7/15 (17.5) kV 

Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-354 Materials : IEC 60092-351, IEC 60092-359

Application Fixed installations in all areas and open deck

Halogen Free Low Smoke Medium Voltage Power Cables with Copper Wire Braiding

HFX‐A/Cu 0.6/1kV 

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

3 x 25  22.5  24  1120  A2023025   

3 x 35  26.5  28  1660  A2023035   

3 x 50  29  30.5  2100  A2023050   

3 x 70  34  36  2950  A2023070   

3 x 95  38.5  40.5  4010  A2023095    

3 x 120  42  44  4990  A2023120    

3 x 150  47.5  50  6150  A2023150    

4 x 1.5  10.8  11.8  180  A2024001    

4 x 2.5  12.2  23.2  225  A2024002    

4 x 4  13.4  14.4  305  A2024004    

4 x 6  15.5  16.5  410  A2024006    

4 x 10  18  19  635  A2024010    

4 x 16  20.5  22  905  A2024016    

4 x 25  25  26.5  1360  A2024025    

 5 x 1.5  12  13  200  A2025001    

7 x 1.5  12.8  13.8  245  A2026071    

10 x 1.5  ‐  ‐  ‐  A2026101    

12 x 1.5  17.5  18.5  435  A2026121    

16 x 1.5  19  20  530  A2026161    

19 x 1.5  20  21.5  610  A2026191    

24 x 1.5  23.5  25  760  A2026241   

27 x 1.5  24  25.5  730  A2026271   

37 x 1.5  26.5  28  1060  A2026371   

HFX‐OSA/Cu 250V 

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

2 x 1.5  9.6  10.6  120  A2022001    

2 x 2.5  10.6  11.6  150  A2022002    

2 x 4  11.8  12.8  195  A2022004    

2 x 6  13  14  275  A2022006    

2 x 10  15.5  16.5  425  A2022010    

2 x 16  18  19  590  A2022016    

3 x 1.5  10.2  11.2  145  A2023001    

3 x 2.5  11  12  185  A2023002    

3 x 4  12.4  13.4  243  A2023004    

3 x 6  13.6  14.6  340  A2023006    

3 x 10  16.5  17.5  520  A2023010    

3 x 16  19  20  750  A2023016    

Test Performance Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359

Halogen Free Low Smoke Power Cables with Copper Wire Braiding

Test Performance Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359

Halogen Free Low Smoke Collectively Screened and Armoured Telecommunication and Instrumentation Cables, Overall Screen with Copper Wire Braiding.

Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Russian Maritime Register of Shipping

Number of Cross   Sectional Area of        Conductor (mm2) 

Max Overall      Diameter (mm) 

Approx Net        Weight of Cables (kg/km) 

BH Code   

1 x 2 x 0.75  10.5  105  A2030121   

1 x 3 x 0.75  ‐  ‐  A2030131   

2 x 2 x 0.75  12.7  155  A2030221   

4 x 2 x 0.75  15.8  265  A2030421    

7 x 2 x 0.75  18.5  370  A2030721    

10 x 2 x 0.75  22.5  500  A2031021    

14 x 2 x 0.75  24.4  620  A2031421    

19 x 2 x 0.75  27.3  800  A2031921    

24 x 2 x 0.75  31.2  980  A2032421    

37 x 2 x 0.75  ‐  ‐  A2033722    

250V 1.5mm2   1 x 2 x 1.5  11.5  135  A2030122    

1 x 3 x 1.5  11  160  A2030132    

2 x 2 x 1.5  14.8  240  A2030222    

4 x 2 x 1.5  18  365  A2030422    

7 x 2 x 1.5  21.3  530  A2030722    

10 x 2 x 1.5  26.2  740  A2031022    

14 x 2 x 1.5  28.4  940  A2031422    

19 x 2 x 1.5  31.6  1200  A2031922    

24 x 2 x 1.5  36.4  1500  A2032422    

37 x 2 x 1.5  ‐    ‐  A2033722   

250V 0.75mm2  

Page 10: 64 - ShipServ · Cables Pg 4  CABLES CONTENTS TFKable Shipboard Cables NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7

Cables

Pg 10

www.bhglobal.com.sg

Number of Cross  Sectional Area of        Conductor (mm2) 

Max Overall      Diameter (mm) 

Approx Net           Weight of Cables   (kg/km) 

BH Code   

250V 0.75mm2   1 x 2 x 0.75  ‐  ‐  A2040121    

1 x 3 x 0.75  ‐  ‐  A2041031    

2 x 2 x 0.75  13.6  170  A2040221    

4 x 2 x 0.75  17  300  A2040421    

7 x 2 x 0.75  20.1  420  A2040721    

10 x 2 x 0.75  24.9  630  A2041021    

14 x 2 x 0.75  27.1  760  A2041421    

19 x 2 x 0.75  30.1  1000  A2041921    

24 x 2 x 0.75  34.1  1190  A2042421    

37 x 2 x 0.75  34.1  1460  A2043721    

1 x 2 x 1.5  ‐  ‐  A2040122    

1 x 3 x 1.5  ‐  ‐  A2040132    

2 x 2 x 1.5  15.7  285  A2040222    

4 x 2 x 1.5  19.3  420  A2040422    

7 x 2 x 1.5  22.8  620  A2040722    

10 x 2 x 1.5  28.4  860  A2041022    

14 x 2 x 1.5  30.9  1100  A2041422    

19 x 2 x 1.5  34.7  1420  A2041922    

24 x 2 x 1.5  39.9  1840  A2042422    

37 x 2 x 1.5  42.3  2180  A2043722   

250V 1.5mm2  

HFX‐ISOSA/Cu 250V 

HFX‐OSA/Cu‐FR 250V 

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

2 x 1.5  11.8  12.8  210  A2122001   

2 x 2.5  13  14  250  A2122002    

2 x 4  14  15  310  A2122004    

3 x 1.5  12.6  13.6  240  A2123001    

3 x 2.5  13.6  14.6  290  A2123002    

3 x 4  14.6  15.6  355  A2123004    

3 x 6  16.5  17.5  490  A2123006    

3 x 10  19  20  690  A2123010    

3 x 16  21.5  23  930  A2123016    

3 x 25  25.5  27  1360  A2123025    

3 x 35  28  29.5  1740  A2123035    

3 x 50  30.5  32.5  2220  A2123050    

3 x 70  35.5  37.5  3060  A2123070    

3 x 95  40  42  4140  A2123095    

3 x 120  44  46  5100  A2123120    

HFX‐A/Cu‐FR 0.6/1kV 

Number of Cross   Sectional Area of        Conductor (mm2) 

Max Overall      Diameter (mm) 

Approx Net        Weight of Cables  (kg/km) 

BH Code   

1 x 2 x 0.75  ‐  ‐  A2150121    

1 x 3 x 0.75  ‐  ‐  A2150131    

2 x 2 x 0.75  21.6  538  A2150221    

4 x 2 x 0.75  24.9  683  A2150421    

250V 0.75mm2  

HFX‐ISOSA/Cu‐FR 250V 

Test Performance Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359

Halogen Free Low Smoke Telecommunication and Instrumentation Cables, Individual Pair Screen with Copper Wire Braiding.

Test Performance Fire Resistant : IEC 60331 Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359

Halogen Free Low Smoke Fire Resistant Armoured Power and Control Cables with Copper Wire Braiding

Test Performance Fire Resistant : IEC 60331 Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359

Halogen Free Low Smoke Fire Resistant Telecommunication and Instrumentation Cables, Individual Pair Screen with Copper Wire Braiding.

Test Performance Fire Resistant : IEC 60331 Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359

Halogen Free Low Smoke Fire Resistant Telecommunication and Instrumentation Cables, Overall Screen with Copper Wire Braiding.

Number of Cross  Sectional Area of        Conductor (mm2) 

Max Overall      Diameter (mm) 

Approx Net         Weight of Cables  (kg/km) 

BH Code   

1 x 2 x 0.75  13  247  A2130121    

1 x 3 x 0.75  13.8  270  A2130131    

2 x 2 x 0.75  19.3  462  A2130221    

4 x 2 x 0.75  22.1  576  A2130421    

7 x 2 x 0.75  25.4  785  A2130721    

10 x 2 x 0.75  31.5  1051  A2131021    

14 x 2 x 0.75  34  1261  A2131421    

19 x 2 x 0.75  37.9  1571  A2131921    

24 x 2 x 0.75  44.6  1998  A2132421   

37 x 2 x 0.75  ‐  ‐  A2133721   

250V 1.5mm2   1 x 2 x 1.5  14.3  300  A2130122   

1 x 3 x 1.5  ‐  ‐  A2130132   

2 x 2 x 1.5  18.1  450  A2130222   

4 x 2 x 1.5  21.6  670  A2130422   

7 x 2 x 1.5  25.5  920  A2130722   

10 x 2 x 1.5  30.8  1250  A2131022   

14 x 2 x 1.5  33.4  1530  A2131422   

19 x 2 x 1.5  37.6  1920  A2131922   

24 x 2 x 1.5  43.2  2470  A2132422   

37 x 2 x 1.5  ‐  ‐  A2133722   

250V 0.75mm2  

Number of Cross Sectional Area of Conductor (mm2) 

Min Overall  Diameter (mm) 

Max Overall Diameter (mm) 

Approx Net      Weight of Cables (kg/km) 

BH Code   

4 x 2.5  14.6  15.6  260  A2124002   

5 x 1.5  14.6  15.6  300  A2125001    

7 x 1.5  16.5  17.5  370  A2126071    

10 x 1.5  20  21.5  540  A2126101    

12 x 1.5  20.5  22  590  A2126121    

16 x 1.5  22.5  24  730  A2126161    

19 x  1.5  23.5  25  820  A2126191    

24 x 1.5  27.5  29  1000  A2126241    

27 x 1.5  28  29.5  1080  A2126271    

37 x 1.5  31  33  1380  A2126371    

3 x 150  47.5  50  6150  A2123150    

4 x 1.5  13.4  14.4  210  A2124001