6305 Hardware Installation Guide

Embed Size (px)

Citation preview

Page 1: 6305 Hardware Installation Guide

Technical Documentation

Copyright © 2006-2007 Tellabs. All rights reserved.

Product family Tellabs® 6300 Managed Transport System

Product name Tellabs® 6305 Ethernet Media Converter

Document Hardware Installation ManualMA373 / Revision A3

Page 2: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Legal Notices

Legal Notices

Copyright Statement This Tellabs manual is owned by Tellabs or its licensors and protected by U.S.and international copyright laws, conventions, and treaties. Your right to usethis manual is subject to limitations and restrictions imposed by applicable li-censes and copyright laws. Unauthorized reproduction, modification, distri-bution, display or other use of this manual may result in criminal and civilpenalties.

Trademark Notice The following trademarks and service marks are owned by Tellabs Opera-tions, Inc., or its affiliates in the United States and/or other countries: AUDIOPLUS®, CABLESPAN®, CEC-128™, DYNAMIC SIGNAL TRANSFER™,DXX®, DXX logo®, EC DUO®, ENHANCED AUDIO PLUS®, EX-PRESS/PATH®, FOCUS™, MARTIS®, MARTISDXX®, MARTIS logo®, MAR-TISDXX logo®, METROVANTAGE®, METROWATCH™, NETREACH®,NETWISE®, SCULPTURED SOUND™, TELLABS®, TELLABS and T sym-bol®, T symbol, TELLABS PROPARTNER™, TEL/MAP™, TEL/MOR®, THEWORLD COMMUNICATES THROUGH TELLABS™, TITAN®, VERITY™,YOUR NETWORKING PARTNER®.

Any other company or product names may be trademarks of their respectivecompanies.

2 MA373 • Rev. A3

Page 3: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Environmental Notices

Environmental Notices

Instructions for use, maintenance and management of residual product

The equipment covered in this manual has been designed to fulfil the environ-mental demands of market and society. There are no apparent hazards duringuse and on-site maintenance of the equipment. We recommend that repair ofdefective equipment takes place at Tellabs premises, and it is likewise recom-mended to dispose of the equipment by use of certified local waste contractorsthat can assure environmental safe handling and disposal of the equipment.Arrangement for disposal of equipment can also be made through Tellabs.

Waste handling in member states of the European Union

The equipment covered in this manual must be disposed of in accordancewith "Directive 2002/96/EC of the European Parliament and of the council of27 January 2003 on waste electrical and electronic equipment (WEEE)".Disposal must follow national legislation for "IT and telecommunicationsequipment" in accordance with the WEEE directive.

• Do not dispose of waste electrical and electronic equipment with unsorted municipal and household waste

• Collect the equipment separately

• Return the equipment through the collection system agreed with Tellabs.

Correct handling of the disposed equipment contributes to reuse, recyclingand other form of recovery to protect the environment.

Label The equipment is marked with the figure shown below, to indicate that theequipment must be collected separately. In case of very small products, thefigure may only be on the packaging or in this manual. The Tellabs name andthe production date will also be labelled on the product.

Further information For further information about separation and handling the disposed equip-ment to ensure correct reuse or recycling, please look at www.tellabs.com.

MA373 • Rev. A3 3

Page 4: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Revision Information

Revision Information

Revision history This manual has changed as follows:

Rev. Date Description of Changes

A1 Dec. 20, 2006 First version of the manual. Describes Tellabs 6305 converter FP1.0.

A2 March 21, 2007 Compared to revision A1:

• Tellabs 6305 converters supporting jumbo frame added.

• Minor changes have been performed.

A3 July 24, 2007 Compared to revision A2:

• The Bank 2 switches are not used in the 10/100/1000 version of the Tellabs 6305 con-verter supporting jumbo frame (CU3421-A). This has been implemented.

4 MA373 • Rev. A3

Page 5: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Warnings

Warnings

Overview It is important that you read this safety information before you begin to installor performing service on the unit.

The procedures in this manual is for use by qualified personnel only. To avoidelectrical shock, do not perform any servicing of this unit other than that con-tained in the procedures, unless you are qualified and certified to do so by Tel-labs.

Laser radiation Be aware of the warnings described here when installing and performing ser-vice on the equipment. The following rules describe how to avoid hazardoussituations.

MA373 • Rev. A3 5

Page 6: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Warnings

6 MA373 • Rev. A3

Page 7: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Contents

Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Environmental Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Revision Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Structure of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Definition of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2 Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.1 Optical Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.2 Labels on Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.3 Physical Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.4 Installing the Transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.5 Connecting the Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3 Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193.1 Front Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193.2 Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193.3 LEDs, Switches and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3.3.1 LEDs, Switches and Connectors on 10/100 Mbit/s Version . . 213.3.2 LEDs, Switches and Connectors on 10/100/1000 Mbit/s Version

253.4 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.5 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

3.5.1 Ethernet Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.5.2 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.5.3 Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.5.4 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.5.5 EMC Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.5.6 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.5.7 R&TTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.5.8 MTBF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

MA373 • Rev. A3 7

Page 8: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Contents

8 MA373 • Rev. A3

Page 9: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Preface

Preface

Introduction This preface describes the purpose of the manual and how the manual is struc-tured. Furthermore you will find explanations of abbreviations, definition ofterms and references used in the manual.

• ‘Purpose of the Manual’ on page 9

• ‘Structure of the Manual’ on page 9

• ‘Abbreviations’ on page 9

• ‘Definition of Terms’ on page 10

• ‘References’ on page 10

Purpose of the Manual

Purpose The purpose of this manual is to:

• Inform the user how to install and connect the Tellabs 6305 converter.

• Provide reference information.

Structure of the Manual

Manual structure The manual is structured as follows:

• ‘1 Overview’ on page 11 introduces the Tellabs 6305 converter.

• ‘2 Installation Information’ on page 13 describes how to install and con-nect the Tellabs 6305 converter.

• ‘3 Reference Information’ on page 19 gives logistics, technical description and specification information about the Tellabs 6305 converter.

Abbreviations

Abbreviations used in this manual

EMC Electromagnetic CompatibilityETEX Ethernet Tributary EXtensionETSI European Telecommunications Standards InstituteFE Fast EthernetFP Feature PackGbE Gigabit EthernetGND GroundID IdentificationIEC International Electrotechnical CommissionLED Light Emitting DiodeMbit/s Megabit per secondMTBF Mean Time Between FailuresNA Not ApplicableNE Network Elementnm nanometer, (1*E-9 meter)ps picosecondsRX ReceiveSFP Small Formfactor Pluggable

MA373 • Rev. A3 9

Page 10: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Preface

STP Shielded twisted pairTX TransmitUTP Unshielded twisted pair

Definition of Terms

System/Network Element:

A complete functional unit with transport and element management function-ality, power supply; all mounted in one or more subracks.

References

References to Tellabs documents

[1] MA345, Tellabs® 6300 Managed Transport System, Tellabs® 6300 Net-work Manager, Managing ETEX, User’s Manual

Note: See the product release notes for a list of manuals that are valid for yourcurrent software/hardware version.

References to external documents

[2] ETSI, EN 300 019-1-x, x = 1 to 8, Equipment Engineering (EE); Environ-mental conditions and environmental tests for telecommunicationsequipment; Classification of environmental conditions, 2003-2004

[3] ETSI, EN 300 019-2-x, x= 1 to 8, Equipment Engineering (EE); Environ-mental conditions and environmental tests for telecommunicationsequipment; Specification of environmental tests, 2003-2004

[4] CEN/CENELEC, EN 55022, Limits and methods of measurements of ra-dio interference characteristics of information technology equipment(CISPR 22:1997 modified), 1998

[5] CEN/CENELEC, EN 55024:1998, Information technology equipment.Immunity characteristics. Limits and methods of measurement, 1998

[6] CEN/CENELEC, EN 60950-1, Safety of information technology equip-ment (including electrical business equipment, with amd. no. 1, 2, 3, 4,11), 2001-2004

[7] CEN/CENELEC, EN 61000, Electrostatic Discharge, Radiated Immunity,Electrical Fast Transient Burst, Surge, Conducted Immunity, MagneticImmunity, Voltage Dips & Interrupts

[8] CEN/CENELEC, EN 60825-1, Safety of laser products. Part 1: Equipmentclassification, requirements and user’s guide, 1994

[9] CEN/CENELEC, EN 60825-2, Safety of laser products. Part 2: Safety ofoptical fibre communication systems, 1997

[10] IEEE 802.3, Standard for Information technology - Telecommunicationsand information exchange between systems - Local and metropolitanarea networks. Part 1D: Media Access Control (MAC) Bridges, 2000.

10 MA373 • Rev. A3

Page 11: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 1 Overview

1 Overview

In this overview This overview gives a short introduction to the Tellabs 6305 converter.

Product relationship The Tellabs 6305 converter is part of the Tellabs product range for access andregional telecommunication transmission networks and based on the stan-dards and recommendations on Ethernet from IEEE.

Overview The Tellabs 6305 converter provides unshielded twisted pair (UTP) to fibermedia conversion with management capability for Operations, Administra-tions and Maintenance (OAM) functionality. The Tellabs 6305 converter isavailable with an external AC power supply in a wall-mountable housing. In-terchangeable Small Formfactor Pluggable (SFP) transceivers with LC connec-tors provide the optical interfaces. SFP fiber transceivers are available for mul-timode (MM) and single-mode (SM) dual fiber (DF), and single-mode single-fiber (SF).

IP-less remote management is supported via 802.3ah OAM protocol.

By offering end-to-end OAM management capabilities with a secure demar-cation point, the Tellabs 6305 converter is the ideal customer premises solu-tion in the First-Mile for Metropolitan Area Networks (MANs).

Layout of the Tellabs 6305 converter

The figure below shows the layout of a Tellabs 6305 converter.

MA373 • Rev. A3 11

Page 12: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 1 Overview

12 MA373 • Rev. A3

Page 13: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 2 Installation Information

2 Installation Information

To install the Tellabs 6305 converter

To complete the installation of the Tellabs 6305 converter, the following stepsmust be performed.

2.1 Optical Safety Considerations

General The Tellabs 6305 converter is classified as a Class 1 laser product in accordancewith IEC 825, that is exposure to hazardous laser radiation is impossible dur-ing normal operation and maintenance. When the system has been installed,the laser radiation is effectively enclosed in the optical fiber path between op-tical equipment at each end.

IEC825 classification limits of optical power radiated from single mode fiber end

Exposure to laser radiation risked during service or installation can be hazard-ous in case of double fault conditions.

Laser warning The illustration describes laser safety rules.

Step Action

1 Read the information in ‘2.1 Optical Safety Considerations’ on page 13, ‘2.2 Labels on Equipment’ on page 14 and ‘2.3 Physical Place-ment’ on page 14.

2 Install the transceiver for the Tellabs 6305 converter as described in ‘2.4 Installing the Transceiver’ on page 15.

3 Check the switch settings described in ‘3.3 LEDs, Switches and Con-nectors’ on page 21.

4 Connect the cables as described in ‘2.5 Connecting the Cables’ on page 16.

Classification 780 nm 850 nm 1310 nm 1550 nm

Class 1(Regarded as safe for all viewing conditions)

- 4.9 dBm - 3.6 dBm +10.0 dBm +10.0 dBm

MA373 • Rev. A3 13

Page 14: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 2 Installation Information

2.2 Labels on Equipment

Identification label on Tellabs 6305 converter

The Tellabs 6305 converter is provided with an identification label as shownin the figure below.

2.3 Physical Placement

Placement rules The Tellabs 6305 converter is designed to operate in a typical commercial en-vironment. Please observe the following rules:

• For AC powering, use a grounded, three-pronged power outlet approved by the electrical code of the region.

• Location must be clean, dust free and well ventilated.

• If required, then install the Tellabs 6305 converter on the wall with four screws

14 MA373 • Rev. A3

Page 15: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 2 Installation Information

2.4 Installing the Transceiver

To insert and remove the transceiver

Follow the instructions.

Step Action

1 Insert the transceiver into the cage.

2 Push the transceiver lightly until it is locked.

3 If you need to remove the transceiver, turn the clip, that locks the transceiver, to the horizontal position. Then you can pull the trans-ceiver out of its cage.

MA373 • Rev. A3 15

Page 16: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 2 Installation Information

2.5 Connecting the Cables

Available cables The cables available for the Tellabs 6305 converter are listed in ‘3.2 Logistics’on page 19.

During installation of cables

Please be aware of this warning.

Warning: During installation it is vital that all interconnection cables are notexposed to overheating from external sources.

To connect the cables The following procedure describes how to connect the cables to the Tellabs6305 converter.

Warning: Care must be taken to protect optical connectors against dust, touch-ing and all contact with other objects.

Note: Disconnected optical connectors must be covered with dust protectingcaps. Do not remove these caps until immediately before installing.

Step Action

1 To ensure the best possible optical connections, it is recommended to clean the optical connectors before use. Use the following items: Lens-cleaning tissue, 2-propanol and Pressurized clean air.

2 Connect the cables for the optical interfaces (P1) on the SFP trans-ceiver.

3 Connect the cable for the electrical UTP interface (P2).

16 MA373 • Rev. A3

Page 17: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 2 Installation Information

To connect the external AC/DC power adapter

The following procedure describes how to connect the external AC/DC pow-er adapter to the Tellabs 6305 converter.

Step Action

1 Connect the cable from the DC output of the AC/DC adapter to the 9 VDC connector on the Tellabs 6305 converter.

2 Connect the AC power cable to the AC/DC adapter (100-240 VAC/50-60Hz/60mA).

Note: The AC power cable is not supplied with the AC/DC adapter.

MA373 • Rev. A3 17

Page 18: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 2 Installation Information

18 MA373 • Rev. A3

Page 19: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

3 Reference Information

Overview The information includes item numbers, functional description and specifica-tions of the Tellabs 6305 converter.

• ‘3.1 Front Layout’ on page 19

• ‘3.2 Logistics’ on page 19

• ‘3.3 LEDs, Switches and Connectors’ on page 21

• ‘3.4 Functional Description’ on page 29

• ‘3.5 Specifications’ on page 31

3.1 Front Layout

Front layout The figure shows the front of the Tellabs 6305 converter.

3.2 Logistics

Versions The following versions of the Tellabs 6305 converter are available.

Note: The following CUxxxx-x numbers consist of a Tellabs 6305 converter(CMxxxx-x) and a power adapter (CM3402).

Description Item number

10/100 Mbit/s Ethernet media converter, sup-porting jumbo frame up to 2 kBytes

CU3411-A

10/100 Mbit/s Ethernet media converter CU3411

10/100/1000 Mbit/s Ethernet media converter, supporting jumbo frame up to 9.6 kBytes

CU3421-A

10/100/1000 Mbit/s Ethernet media converter CU3421

MA373 • Rev. A3 19

Page 20: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

Transceivers The following transceivers are available for the Tellabs 6305 converter.

Interface cables The following interface cables are available for the Tellabs 6305 converter.

Description Item number

Transceivers for 10/100 Mbit/s version

100BASE-FX transceiver, SFP, LC connectors, multi mode fiber

TR-0010

100BASE-LX10 transceiver, SFP, LC connectors, single mode fiber

TR-0022

Transceivers for 10/100/1000 Mbit/s version

1000BASE-SX transceiver, SFP, LC connectors, multi mode fiber

TR-0011

1000BASE-LX10 transceiver, SFP, LC connectors, multi/single mode fiber

TR-0012

1000BASE-ZX transceiver, SFP, LC connectors, single mode fiber

TR-0023

Description Item number

Optical single mode fiber cables, two fibers in one cable

2xLC to 2xLC single mode fiber cable, 5 m W-OF203/05.0

2xLC to 2xLC single mode fiber cable, 10 m W-OF203/10.0

2xLC to 2xLC single mode fiber cable, 20 m W-OF203/20.0

2xLC to 2xFC/PC single mode fiber cable, 5 m W-OF204/05.0

2xLC to 2xFC/PC single mode fiber cable, 10 m W-OF204/10.0

2xLC to 2xFC/PC single mode fiber cable, 20 m W-OF204/20.0

2xLC to 2xSC single mode fiber cable, 5 m W-OF205/05.0

2xLC to 2xSC single mode fiber cable, 10 m W-OF205/10.0

2xLC to 2xSC single mode fiber cable, 20 m W-OF205/20.0

Optical multi mode fiber cables, two fibers in one cable

2xLC to 2xLC multi mode fiber cable, 5 m W-OF207/05.0

2xLC to 2xLC multi mode fiber cable, 10 m W-OF207/10.0

2xLC to 2xLC multi mode fiber cable, 20 m W-OF207/20.0

20 MA373 • Rev. A3

Page 21: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

3.3 LEDs, Switches and Connectors

Overview The LEDs, switches and connectors of the two versions of the Tellabs 6305converter are described in:

• ‘3.3.1 LEDs, Switches and Connectors on 10/100 Mbit/s Version’ on page 21

• ‘3.3.2 LEDs, Switches and Connectors on 10/100/1000 Mbit/s Version’ on page 25

3.3.1 LEDs, Switches and Connectors on 10/100 Mbit/s Version

LEDs and switches on the 10/100 Mbit/s version of the Tellabs 6305 converter

The figure below shows the location of the LEDs, switches and connectors onthe 10/100 Mbit/s version of the Tellabs 6305 converter.

The functions of the LEDs are described in the table below.

LED Color Description

Pwr Amber Power

• Off: No power

• On: Module has power

FO Green 100 Mbit/s fiber optics

• Off: No fiber link

• On: Fiber link is active

• Blinking: Receiving fiber data

MA373 • Rev. A3 21

Page 22: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

The functions of the switches are described in the table below.

10 Green UTP port 10 Mbit/s

• Off: 10 Mbit/s is not active

• On: 10 Mbit/s mode selected and the UTP link is active

• Blinking: Receiving UTP data

100 Green UTP port 100 Mbit/s

• Off: 100 Mbit/s is not active

• On: 100 Mbit/s mode selected and the UTP link is active

• Blinking: Receiving UTP data

FDX Green UTP port full-duplex

• Off: Half-duplex when UTP link is active

• On: Full-duplex and UTP link is active

SwitchDescription

Down pos. (factory default) Up pos.

1 Pause disable (Off) Pause enable (On)

2 Fiber full-duplex (FDX) Fiber half-duplex (HDX)

3 UTP auto-negotiation (AN) UTP manual negotiation (MAN)

4 UTP 100 Mbit/s (100) UTP 10 Mbit/s (10)

5 UTP full-duplex (FDX) UTP half-duplex (HDX)

6 Link segment (LS) Link propagation (LP)

7 RFD off (Off) Remote fault detection (RFD). This function is not used.

8 SFD off (Off) Symmetrical fault detection (SFD). This function is not used.

LED Color Description

22 MA373 • Rev. A3

Page 23: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

Detailed functional description of the switches

The switches are described in the following.

• SW1 - Pause Disable/Enable (Off/On)

When a port is operating in Auto-Negotiation, its Pause operation mode isdetermined by the Pause capability advertised during Auto-Negotiationbetween itself and the link partner. The port advertises its Pause capabilityduring Auto-Negotiation based on the Pause Disable/Enable DIP-switchsetting. Setting the Pause DIP-switch to the DOWN "Off" position (factorydefault) forces the port to negotiate to No Pause mode with its link partner.Setting the Pause DIP-switch to the UP "On" position allows the port to ne-gotiate to Symmetrical Pause, Asymmetrical Pause or No Pause mode withits link partner.

When a port is operating in Manual mode, its Pause operation mode isbased on the Pause Disable/Enable DIP-switch setting. Setting the PauseDIP-switch to the DOWN "Off" position (factory default) forces the port tooperate in No Pause mode. Setting the Pause DIP-switch to the UP "On"position allows the port to operate in Symmetrical Pause mode.

• SW2 - Fiber Full/Half-Duplex (FDX/HDX)

When the fiber Full/Half-Duplex DIP-switch is in the DOWN "FDX" posi-tion (factory default), the fiber operates in Full-Duplex mode to facilitate aconnection to a switch or a workstation that supports Full-Duplex opera-tion. Setting this DIP-switch to the UP "HDX" position facilitates a Half-Duplex connection to a hub (with a shared/non-switched fiber port) or aworkstation that supports only Half-Duplex.

• SW3 - UTP Auto/Manual Negotiation (AN/Man)

When this DIP-switch is in the DOWN Auto-Negotiation "AN" position(factory default), the UTP port automatically determines the speed and du-plex mode of the connecting UTP device. If the connecting UTP device can-not provide the proper signal to indicate its own mode of operation, thenthis DIP-switch should be set to the UP "Man" position. Manual mode re-quires manually configuring the UTP port to match the speed and the du-plex mode of the connecting UTP device (configurable using the "10/100"and UTP "FDX/HDX" DIP-switches).

• SW4 - UTP 10/100Mbps (10/100)

When the UTP "AN/Man" DIP-switch (described above) is in the Manual"Man" position, the "10/100" DIP-switch determines the speed of operationfor the UTP port. Setting the "10/100" DIP-switch to the DOWN "100" po-sition (factory default) forces the UTP port to operate at 100Mbps. Settingthis DIP-switch to the UP "10" position forces the UTP port to operate at10Mbps. Adjust the "10/100" DIP-switch to match the speed of the connect-ing UTP device.

When the UTP "AN/Man" DIP-switch is in the Auto Negotiate "AN" posi-tion and the UTP 10/100 DIP-switch is in the "100" position, the UTP portauto-negotiates to 100Mbps or 10Mbps. When in the "10" position, the UTPport only operates at 10Mbps.

• SW5 - UTP Full/Half-Duplex (FDX/HDX)

When the UTP "AN/MAN" DIP-switch is in the "Man" position, the UTP"FDX/HDX" DIP-switch determines the duplex operation mode for theUTP port. Setting the UTP "FDX/HDX" DIP-switch to the DOWN "FDX"position (factory default) forces the UTP port to operate in Full-Duplex.Setting this DIP-switch to the UP "HDX" forces the UTP port to operate inHalf-Duplex. Adjust the UTP "FDX/HDX" DIP-switch to match the con-necting device.

MA373 • Rev. A3 23

Page 24: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

When the UTP "AN/Man" DIP-switch is in the Auto Negotiate "AN" posi-tion, and the UTP "FDX/HDX" DIP-switch is in the Full-Duplex "FDX" po-sition, the UTP port auto negotiates to Full or Half-Duplex. When in theHalf-Duplex "HDX" position, the UTP port functions only in Half-Duplex.

• SW6, SW7 and SW8 - Link Mode

For a functional description of the link modes see ‘Link modes’ on page 30.These three DIP-switches configure the link mode settings. The table in‘Link mode switches’ on page 24 details possible Link Mode DIP-switchconfigurations.

Link mode switches The table below shows the Link Mode DIP-Switch Settings for different con-figurations.

Connectors on the Tellabs 6305 converter

The functions of the connectors are described in the table below.

SW6 SW7 SW8 Result

LS OFF OFF Enables Link Segment mode (LS)

LP OFF OFF Enables Link Propagate mode (LP)

Connector Description

P1 Fast Ethernet optical connections via SFP transceiver

P2 UTP 10/100 Mbit/s connection (RJ-45)

9 VDC DC input from AC/DC adapter

Serial Console Not used

24 MA373 • Rev. A3

Page 25: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

3.3.2 LEDs, Switches and Connectors on 10/100/1000 Mbit/s Version

LEDs and switches on the 10/100/1000 Mbit/s version of the Tellabs 6305 converter

The figure below shows the location of the LEDs, switches and connectors onthe 10/100/1000 Mbit/s version of the Tellabs 6305 converter.

Note: The Bank 2 switches are not used in CU3421-A.

The functions of the LEDs are described in the table below.

LED Color Description

Pwr Amber Power

• Off: No power

• On: Module has power

FO Green 1000 Mbit/s fiber optics

• Off: No fiber link

• On: Fiber link is active

• Blinking: Receiving fiber data

100 Green UTP port 10+100 Mbit/s

• Off: 10+100 Mbit/s is not active

• On: UTP linked at 100 Mbit/s; if 1000 is also on, then UTP linked at 10 Mbit/s

• Blinking: Receiving UTP data

1000 Green UTP port 10+1000 Mbit/s

• Off: 100+1000 Mbit/s is not active

• On: UTP linked at 1000 Mbit/s; if 100 is also on, then UTP linked at 10 Mbit/s

• Blinking: Receiving UTP data

MA373 • Rev. A3 25

Page 26: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

The functions of the switches are described in the table below.

FDX Green UTP port full-duplex

• Off: Half-duplex when any UTP link is active

• On: Full-duplex when any UTP link is active

SwitchDescription

Down pos. (factory default) Up pos.

Bank 1 (CU3421 and CU3421-A)

1 Fiber auto-negotiation (AN) Fiber manual mode (MAN)

2 UTP auto-negotiation (AN) UTP manual mode (MAN)

3 UTP 1000 Mbit/s (1000) UTP 10-100 Mbit/s (10-100)

4 UTP 100 Mbit/s (100) UTP 10 Mbit/s (10)

5 UTP full-duplex (FDX) UTP half-duplex (HDX)

6 Link segment (LS) Link propagation (LP)

7 RFD off (Off) Remote fault detection (RFD). This function is not used.

8 SFD off (Off) Symmetrical fault detection (SFD). This function is not used.

Bank 2 (CU3421 only)

3 Pause disable (Off) Pause enable (On)

4 Option 1 (Reserved) Option 1 (Reserved)

5 UTP auto crossover enable (Auto)

UTP manual crossover enable (Man)

6 UTP crossover disable (=) UTP crossover enable (X)

7 Option 2 (Reserved) Option 2 (Reserved)

8 Option 3 (Reserved) Option 3 (Reserved)

LED Color Description

26 MA373 • Rev. A3

Page 27: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

Detailed functional description of the Bank 1 switches (CU3421 and CU3421-A)

The switches of Bank 1 are described in the following.

• SW1 - Fiber Optic Auto/Manual Negotiation (AN/Man)

When this DIP-switch is in the DOWN fiber optic Auto-Negotiate "AN"position (factory default), the fiber optic port automatically determines theduplex and pause modes of the connecting fiber optic device. If the con-necting fiber optic device cannot provide the proper signal to indicate itsown mode of operation, the DIP-switch should be set to the UP fiber opticManual mode "Man" position.

Note: Note that when the fiber optic port operates in Auto-Negotiation mode,the port advertises for Pause. When the fiber optic port operates inManual mode, Pause is disabled.

Note: Note that the fiber optic port of the Tellabs 6305 converter works in Full-Duplex mode in both Auto and Manual Negotiation modes.

• SW2 - UTP Auto/Manual Negotiation (AN/Man)

This DIP-switch enables and disables the UTP Auto-Negotiation featurewhen the UTP "1000/10-100" DIP-switch is in the Fast Ethernet "10-100"position. This switch has no effect when the UTP "1000/10-100" DIP-switchis in the Gigabit "1000" position. The UTP port always operates in Auto-Ne-gotiation mode when the UTP port is set to Gigabit (10/100/1000Mbps)mode.

When this DIP-switch is in the DOWN UTP Auto-Negotiate "AN" position(factory default), the UTP port automatically determines the Speed, Du-plex and Pause mode of the connecting UTP device. If the connecting UTPdevice cannot provide the proper signal to indicate its own mode of oper-ation, then the DIP-switch should be set to the UP UTP Manual mode"Man" position. Manual mode requires manually configuring the UTP portto match the Speed, Duplex and Pause mode of the connecting UTP deviceusing the "10/100", "FDX/HDX", "Pause Disable/Pause Enable" DIP-switches.

• SW3 - UTP Speed Gigabit/10-100 (1000/10-100)

When the "1000/10-100" DIP-switch is in the DOWN Gigabit "1000" posi-tion (factory default), the UTP always operates in 10/100/1000Mbps Auto-Negotiation mode. The UTP port auto-negotiates to a speed of 10Mbps,100Mbps or 1000Mbps with the connected UTP device. In this mode, theUTP "AN/Man" and UTP "100/10" DIP-switches have no effect.

When the "1000/10-100" DIP-switch is in the UP 10/100Mbps "10-100" po-sition and the UTP "AN/Man" DIP-switch is in the "Manual" position, theUTP port operates at the Speed and Duplex modes set by the "10/100" and"FDX/HDX" DIP-switches.

When the "1000/10-100" DIP-switch is in the 10/100Mbps "10-100" posi-tion and the UTP "AN/Man" DIP-switch is in the Auto-Negotiation "AN"position, the maximum Auto-Negotiation setting for the Speed, Duplexand Pause mode of the UTP port is limited by the "10/100", "FDX/HDX"and Pause "Off/On" DIP-switches.

• SW4 - UTP 100/10Mbps (100/10)

This DIP-switch has no effect when the UTP "1000/10-100" DIP-switch isin the Gigabit "1000" position. Set the UTP "1000/10-100" DIP-switch to the10/100Mbps "10-100" position before configuring the UTP 100/10Mbps"100/10" DIP-switch.

When the UTP "AN/Man" DIP-switch (described above) is in the manual"Man" position, the "100/10" DIP-switch determines the speed of operation

MA373 • Rev. A3 27

Page 28: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

for the UTP port. Setting the "100/10" DIP-switch to the UTP 100Mbps"100" position (factory default) forces the UTP port to operate only at100Mbps. Setting this DIP-switch to UTP 10Mbps "10" position forces theUTP port to operate only at 10Mbps. Set the "100/10" DIP-switch to matchthe speed of the connected UTP device.

When the UTP "AN/Man" DIP-switch is in the Auto-Negotiate "AN" posi-tion and the UTP 10/100 DIP-switch is in the "100" position, the UTP portauto-negotiates to 100Mbps or 10Mbps. When in the "10" position, the UTPport only operates at 10Mbps.

• SW5 - UTP Full/Half Duplex (FDX/HDX)

When the UTP "AN/Man" DIP-switch is in the UP "Man" position (whichis disabled when the UTP port is configured for Gigabit "1000Mbps" oper-ation), the UTP Full/Half-Duplex "FDX/HDX" DIP-switch determines theduplex operation mode of the UTP port. Setting the UTP Full/Half-DuplexDIP-switch to the DOWN UTP Full-Duplex "FDX" position (factory de-fault) forces the UTP port to operate in Full-Duplex. Setting this DIP-switch to UTP Half-Duplex "HDX" forces the UTP port to operate in Half-Duplex. Adjust the UTP Full/Half-Duplex DIP-switch to match the duplexmode of the connected UTP device.

When the UTP "AN/Man" DIP-switch is in the Auto-Negotiate "AN" posi-tion, and the UTP Full/Half-Duplex DIP-switch is in the Full-Duplex"FDX" position, the UTP port auto-negotiates to Full or Half-Duplex. TheUTP port functions only in Half-Duplex when it is in the Half-Duplex"HDX" position.

• SW6, SW7 and SW8 - Link Mode

For a functional description of the link modes see ‘Link modes’ on page 30.These three DIP-switches configure the link mode settings. The table in‘Link mode switches’ on page 28 details possible Link Mode DIP-switchconfigurations.

Link mode switches The table below shows the Link Mode DIP-Switch Settings for different con-figurations.

Detailed functional description of the Bank 2 switches (CU3421 only)

The switches of Bank 2 are described in the following.

• SW3 - Pause Disable/Enable (Off/On)

When the UTP port is operating in Auto-Negotiation mode, it advertisesfor Pause based on the Pause Disable/Enable "Off/On" DIP-switch setting.Setting the Pause DIP-switch to the Pause Disable "Off" position (factorydefault) forces the UTP port to negotiate to No Pause. Setting this DIP-switch to the Pause Enable "On" position allows the UTP port to negotiateto Symmetrical Pause, Asymmetrical Pause or No Pause mode. When theUTP port is operating in Manual mode, Pause is disabled.

Note: Note that when the Fiber optic port operates in Auto-Negotiationmode, the port advertises for Pause. When the Fiber optic port operatesin Manual mode, Pause is disabled.

SW6 SW7 SW8 Result

LS OFF OFF Enables Link Segment mode (LS)

LP OFF OFF Enables Link Propagate mode (LP)

28 MA373 • Rev. A3

Page 29: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

• SW5 - UTP 10/100 Auto/Manual Crossover (Auto/Man)

The Tellabs 6305 converter features 10/100 Auto Crossover, which allowsit to connect to a switch or a workstation with either straight-through orcrossover UTP cables.

The 10/100 Auto Crossover feature is only available when the UTP port isoperating in Auto-Negotiation mode. The UTP port operates in Auto-Ne-gotiation mode when the "AN/Man" DIP-switch is in the Auto-Negotiate"AN" position, or when the "1000/10-100" DIP-switch is in the Gigabit"1000" position.

The 10/100 Auto Crossover feature is not available when the UTP port isoperating in Manual mode. The UTP port operates in Manual mode whenthe "AN/Man" DIP-switch is in the "Man" Manual position and the "1000/10-100" DIP-switch is the Fast Ethernet "10-100" position.

When this DIP-switch is set to Auto Crossover "Auto" (factory default), the10/100 UTP Auto Crossover feature is enabled. When it is set to ManualCrossover "Man", the UTP Manual Crossover DIP-switch is enabled to al-low the user to manually set either a Crossover or Straight-through con-nection.

• SW6 - UTP Manual Crossover (=/X)

When the UTP Auto/Manual Crossover DIP-switch is set to Crossover"Man", the UTP Manual Crossover DIP-switch is enabled. When connect-ing the UTP port to a workstation, set this DIP-switch to Straight-Through"=" (factory setting). When connecting to a hub or switch, set this DIP-switch to Crossover "X". Only use this setting in 10/100Mbps manualmode.

Connectors on the Tellabs 6305 converter

The functions of the connectors are described in the table below.

3.4 Functional Description

Overview The Tellabs 6305 converter provides unshielded twisted pair (UTP) to fibermedia conversion with management capability for Operations, Administra-tions and Maintenance (OAM) functionality. The Tellabs 6305 converter isavailable in two versions. One version of the Tellabs 6305 converter provides10BASE-T or 100BASE-TX UTP to optical fast Ethernet (100 Mbit/s) fiber me-dia conversion. The other version of the Tellabs 6305 converter provides10BASE-T, 100BASE-TX, or 1000BASE-T UTP to Gigabit fiber media conver-sion. The Tellabs 6305 converter is available with an external AC power sup-ply in a wall-mountable housing. Interchangeable Small Formfactor Plugga-ble (SFP) transceiver with LC connectors provides the optical interfaces. SFPfiber transceivers are available for multimode (MM) and single-mode (SM)dual fiber (DF), and single-mode single-fiber (SF).

Connector Description

P1 Gigabit Ethernet optical connections via SFP transceiver

P2 UTP 10/100/1000 Mbit/s connection (RJ-45)

9 VDC DC input from AC/DC adapter

Serial Console Not used

MA373 • Rev. A3 29

Page 30: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

Several Link Modes (fault-detection capabilities) are available through theTellabs 6305 converter, including Link Segment (Normal Mode) and LinkPropagate (Link Loss Carry Forward). The Tellabs 6305 converter also re-modulates and regenerates outbound data signals to prevent signal degrada-tion.

The Tellabs 6305 converter collects and reports real-time network and equip-ment status such as link status.

IP-less remote management is supported via 802.3ah OAM protocol.

By offering end-to-end OAM management capabilities with a secure demar-cation point, the Tellabs 6305 converter is the ideal customer premises solu-tion in the First-Mile for Metropolitan Area Networks (MANs).

Link modes In order to accommodate different user needs, the Tellabs 6305 converter sup-ports several different link modes.

In "Link Segment" (LS), sometimes referred to as the Normal mode, a porttransmits a Link signal independently of any received Link at any other port.For example, the UTP transmits a Link regardless of the fiber receiving a Link(Fig. A & B)

In "Link Propagate" (LP), sometimes referred to as Link Loss Carry Forward,a port transmits a Link signal only when receiving a Link at its other port. Forexample, the UTP transmits a Link only when receiving a Link at the fiber port(Fig. C).

30 MA373 • Rev. A3

Page 31: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

3.5 Specifications

Overview The specifications for the Tellabs 6305 converter are described in:

• ‘3.5.1 Ethernet Interfaces’ on page 31

• ‘3.5.2 Power’ on page 36

• ‘3.5.3 Mechanical’ on page 36

• ‘3.5.4 Environmental’ on page 37

• ‘3.5.5 EMC Conditions’ on page 37

• ‘3.5.6 Safety’ on page 37

• ‘3.5.7 R&TTE’ on page 37

• ‘3.5.8 MTBF’ on page 38

3.5.1 Ethernet Interfaces

Electrical ports The following table shows the specifications for the electrical Ethernet ports.

100BASE-FX ports The 100BASE-FX interfaces are according to ANSI X3.237-1995 and are sup-plied with LC connectors.

Parameter Value for electrical Ethernet ports

Interface • 10BASE-T: 10 Mbit/s full duplex STP CAT3/5 ca-ble

• 100BASE-TX: 100 Mbit/s full duplex STP CAT5 cable

• 1000BASE-T: 1 Gbit/s full duplex four-pair STP CAT5 cable

Bit rate The pay-load bit rates are:

• 10BASE-T: 10 Mbit/s ± 100 ppm

• 100BASE-TX: 100 Mbit/s ± 100 ppm

• 1000BASE-T: 1 Gbit/s ± 50 ppm

Signalling speed The signalling speeds are:

• 10BASE-T: 12.5 Mbit/s ± 100 ppm

• 100BASE-TX: 125 Mbit/s ± 100 ppm

• 1000BASE-T: 1.25 Gbit/s ± 50 ppm

Connector RJ-45

Standards IEEE 802.3

Parameter Minimum Maximum Unit

Fiber type • 50 μm multi mode

• 62.5 μm multi mode

MA373 • Rev. A3 31

Page 32: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

100BASE-LX10 ports The 100BASE-LX10 interfaces are according to IEEE802.3ah and are suppliedwith LC connectors.

Transmitter

Center wavelength (λ, range) 1270 1380 nm

Spectrum FWHM na 250 nm

Average power -22.0 -14.0 dBm

Trise (10% - 90%) na 4.0 ns

Tfall (90% - 10%) na 4.0 ns

Duty cycle distortion, peak-peak 0.0 1.0 ns

Data dependent jitter, peak-peak 0.0 0.6 ns

Random jitter, peak-peak 0.0 0.76 ns

Extinction ratio (min) 0.0 10.0 %

Receiver

Center wavelength (λ, range) 1270 1380 nm

Average power -29.0 -14.0 dBm

Trise (10% - 90%) na 4.5 ns

Tfall (90% - 10%) na 4.5 ns

Duty cycle distortion, peak-peak 0.0 1.0 ns

Data dependent jitter, peak-peak 0.0 0.6 ns

Random jitter, peak-peak 0.0 0.76 ns

Parameter Minimum Maximum Unit

Parameter Value Unit

Fiber type 10 μm single mode

Transmitter

Transmitter type Longwave laser

Signalling speed (range) 125 ± 50 ppm Mbit/s

Wavelength (λ, range) 1260 to 1360 nm

RMS spectral width (max) 7.7 nm

Average launch power (max) -8 dBm

Average launch power (min) -15 dBm

Average launch power of OFF transmit-ter (max)

-45 dBm

32 MA373 • Rev. A3

Page 33: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

1000BASE-SX ports The 1000BASE-SX interfaces are according to IEEE802.3 and are supplied withLC connectors.

Extinction ratio (min) 5 dB

RIN (max) -110 dB/Hz

Receiver

Signalling speed (range) 125 ± 50 ppm Mbit/s

Wavelength (λ, range) 1260 to 1360 nm

Average receive power (max) -8 dBm

Receive sensitivity (max) -25 dBm

Return loss (min) 12 dB

Stressed receive sensitivity -20.1 dBm

Vertical eye-closure penalty (min) 3.7 dB

Parameter Value Unit

Parameter Value Unit

Fiber type • 50 μm multi mode

• 62.5 μm multi mode

Transmitter

Transmitter type Shortwave laser

Signalling speed (range) 1.25 ± 100 ppm Gbit/s

Wavelength (λ, range) 770 to 860 nm

Trise/Tfall (max: 20% - 80%, λ > 830 nm) 0.26 ns

Trise/Tfall (max: 20% - 80%, λ < 830 nm) 0.21 ns

RMS spectral width (max) 0.85 nm

Average launch power (max) • -4.9 @ 780 nm

• -3.6 @ 850 nm

dBm

Average launch power (min) -9.5 dBm

Average launch power of OFF transmit-ter (max)

-30 dBm

Extinction ratio (min) 9 dB

RIN (max) -117 dB/Hz

Coupled Power Ratio (CPR) (min) 9 < CPR dB

Receiver

MA373 • Rev. A3 33

Page 34: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

1000BASE-LX10 ports The 1000BASE-LX10 interfaces are according to IEEE802.3 and are suppliedwith LC connectors.

Signalling speed (range) 1.25 ± 100 ppm Gbit/s

Wavelength (λ, range) 770 to 860 nm

Average receive power (max) 0 dBm

Receive sensitivity -17 dBm

Return loss (min) 12 dB

Stressed receive sensitivity • -13.5 for 50 μm multi mode fiber

• -12.5 for 62.5 μm multi mode fiber

dBm

Vertical eye-closure penalty • 2.20 for 50 μm multi mode fiber

• 2.60 for 62.5 μm multi mode fiber

dB

Receive electrical 3 dB upper cutoff fre-quency (max)

1500 MHz

Parameter Value Unit

Parameter Value Unit

Fiber type • 50 μm multi mode

• 62.5 μm multi mode

• 10 μm single mode

Transmitter

Transmitter type Longwave laser

Signalling speed (range) 1.25 ± 100 ppm Gbit/s

Wavelength (λ, range) 1260 to 1360 nm

Trise/Tfall (max: 20% - 80% response time)

0.30 ns

RMS spectral width (max) 3.5 nm

Average launch power (max) -3 dBm

Average launch power (min) • -11 for 50 μm and 62.5 μm multi mode fibers

• -9 for 10 μm single mode fiber

dBm

Average launch power of OFF transmit-ter (max)

-45 dBm

34 MA373 • Rev. A3

Page 35: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

1000BASE-ZX ports The 1000BASE-ZX interfaces are supplied with LC connectors.

Extinction ratio (min) 6 dB

RIN (max) -113 dB/Hz

Receiver

Signalling speed (range) 1.25 ± 100 ppm Gbit/s

Wavelength (λ, range) 1260 to 1360 nm

Average receive power (max) -3 dBm

Receive sensitivity -19.5 dBm

Return loss (min) 12 dB

Stressed receive sensitivity -15.4 dBm

Vertical eye-closure penalty 3.60 dB

Receive electrical 3 dB upper cutoff fre-quency

max. 1500 MHz

Parameter Value Unit

Parameter Value Unit

Fiber type 10 μm single mode

Transmitter

Transmitter type Longwave laser

Signalling speed (range) 1.25 ± 100 ppm Gbit/s

Wavelength (λ, range) 1540 to 1570 nm

Trise/Tfall (max: 20% - 80% response time)

0.26 ns

Spectral width, - 20 dB (max) 1 nm

Average launch power (max) 5 dBm

Average launch power (min) 0 dBm

Average launch power of OFF transmit-ter (max)

-30 dBm

Extinction ratio (min) 9 dB

RIN (max) -120 dB/Hz

Receiver

Signalling speed (range) 1.25 ± 100 ppm Gbit/s

Wavelength (λ, range) 1540 to 1570 nm

Average receive power (max) 0 dBm

MA373 • Rev. A3 35

Page 36: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

3.5.2 Power

AC power The table lists the AC power adapter specifications.

3.5.3 Mechanical

Dimensions The dimensions of the Tellabs 6305 converter are shown in the table below.

Weight The weight of the Tellabs 6305 converter is shown in the table below.

Transport It is recommended to use the factory supplied packaging if you need to trans-port the Tellabs 6305 converter.

Connectors The table specifies the connectors on the of the Tellabs 6305 converter.

Receive sensitivity -22 dBm

Return loss (min) 12 dB

Stressed receive sensitivity (max) -14.5 dBm

Receive electrical 3 dB upper cutoff fre-quency (max)

1500 MHz

Parameter Value Unit

Parameter Value

Nominal Voltage 100 - 240 VAC

Input Frequency 50 - 60 Hz

Current 60 mA

Height (mm) Width (mm) Depth (mm)

26 97 120

Parameter Weight (Kg)

Without power adapter 0.45

With power adapter 0.68

Function Equipment Connector Type

UTP interface RJ-45

Optical interface LC (with SFP transceiver)

DC power input

Serial Console Not used

36 MA373 • Rev. A3

Page 37: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

3.5.4 Environmental

Climatic and mechanical conditions

Classification according to ETSI ETS 300 019-1:

• In use:

ETS 300 019-1-3 class 3.4, stationary use at weather protected locations,sites with heat traps.

Climatic and mechanical conditions

The table specifies climatic and mechanical conditions of the Tellabs 6305 con-verter during operation.

3.5.5 EMC Conditions

Compliance The principal protection requirements of the EMC Directive 89/336/EEC and93/68/EEC are satisfied.

3.5.6 Safety

Compliance The principal protection requirements of the low voltage directive 73/23/EECare satisfied.

Safety requirements The requirements of EN 60950-1 “Safety of information technology equip-ment” is fulfilled. The intended use of the Tellabs 6305 converter is on restrict-ed access locations as defined in EN 60950-1.

The requirements of EN 60825-1: Equipment classification, requirements anduser’s guide, and EN 60825-2: Safety of optical fibre communication systems,are fulfilled.

3.5.7 R&TTE

Compliance The principal protection requirements of the Radio Equipment and Telecom-munications Terminal Equipment Directive (R&TTE) 1999/5/EC are satis-fied.

Requirements This is verified by performing the tests according to the EMC directive and theLVD directive, i.e.:

• EN 300 386: Telecommunication Network Equipment, EMC requirements. Sub clause 7.2 Equipment operating in locations other than telecommuni-cation centres, see part 5 of this document.

• EN 60950-1: Safety of information technology equipment.

Parameter In use

Temperature -5 °C to +45 °C

Humidity 0% to 90%, non-condensing

MA373 • Rev. A3 37

Page 38: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter 3 Reference Information

Connections It is only the optical interfaces of the Tellabs 6305 converter, that are intendedto be connected to interfaces of public telecommunications networks.

The safety status of the electrical interfaces of the Tellabs 6305 converter isSELV circuit according to EN 60950-1.

The electrical interfaces of the Tellabs 6305 converter must only be connectedto other earthed equipment, and must not be connected directly to outdoorsignal lines.

3.5.8 MTBF

MTBF values The table specifies the MTBF values for the Tellabs 6305 converter items.

Operational lifetime The Tellabs 6305 converter is designed for a 15 year lifetime.

Item MTBF (years)

CU3411-A without power adapter 68.5

CU3411-A with power adapter 28.5

CU3421-A without power adapter 68.5

CU3421-A with power adapter 28.5

TR-0010 100

TR-0011 100

TR-0012 100

TR-0022 100

TR-0023 100

38 MA373 • Rev. A3

Page 39: 6305 Hardware Installation Guide

Tellabs® 6305 Ethernet Media Converter Index

Index

AAbbreviations 9AC input 36

CCables 20

Connecting 16Installing 16

Cabling 16Connecting

Cables 16Power cable 17

Connectors 21, 25Considerations 13

DDefinition of Terms 10Description 29

EEMC 37Environmental 37Environmental notices 3Equipment labels 14

FFront Layout 19Functional description 29

IIdentification

Labels 14Installation 13Installing

Cables 16Power cable 17Transceivers 15

Item numbers 19

LLabels 14Layout 11, 19LEDs 21, 25Location 14Logistics 19

MManual

Purpose 9Structure 9

Mechanical 36MTBF 38

NNumbers 19

OOptical Safety 13Ordering numbers 19

PPhysical placement 14Power 36Power cable

Connecting 17Installing 17

Precautions 5Purpose of manual 9

RR&TTE 37References 10Removing

Transceivers 15

SSafety 13, 37Specifications 31

EMC 37Environmental 37Ethernet interface 31Mechanical 36MTBF 38Power 36R&TTE 37Safety 37

Structure of manual 9Switch 21, 25

TTerms 10Transceivers

Installing 15

MA373 • Rev. A3 39