Upload
themountainaa
View
34
Download
4
Embed Size (px)
DESCRIPTION
FRGH SW Upgrade
Citation preview
11 Nokia Siemens Networks DRAFT Issue Confidental
LTE eNB Hands-on TrainingLTE SW Upgrade For FRGH
22 Nokia Siemens Networks DRAFT Issue
Nokia Siemens Networks Academy
Legal notice
Intellectual Property RightsAll copyrights and intellectual property rights for Nokia Siemens Networks training documentation, product documentation and slide presentation material, all of which are forthwith known as Nokia Siemens Networks training material, are the exclusive property of Nokia Siemens Networks. Nokia Siemens Networks owns the rights to copying, modification, translation, adaptation or derivatives including any improvements or developments. Nokia Siemens Networks has the sole right to copy, distribute, amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals can use the Nokia Siemens Networks training material for their own personal self-development only, those same individuals cannot subsequently pass on that same Intellectual Property to others without the prior written agreement of Nokia Siemens Networks. The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networks training session for development of groups without the prior written agreement of Nokia Siemens Networks.
33 Nokia Siemens Networks DRAFT Issue
Module Contents
SW Upgrade on FRGH How to configure FTP server for SW upgrade How to open telnet, FTP and Web Interface on FRGH Commands used on Command Line and Web Interface
44 Nokia Siemens Networks DRAFT Issue
FRGH: IP Addresses and Ports Used
192.168.255.69:21FTP
192.168.255.69:12080HTTP
192.168.255.69:2323telnet
192.168.255.126
FRGH
55 Nokia Siemens Networks DRAFT Issue
Recommendation For FRGH Upgrade
Starting with LN1.0 18.15-14 eNB SW load is delivered with BTSOM activated. It is strictly recommended to use the Ethernet port of RRH during SW update!
Switch power off on eNB system. Plug out fibre optic cable and SFP module on RRH. Connect the twisted pair cable of our local maintenance terminal (LMT) with the RRH. Switch power on again. Ping to 192.168.255.69 should work.
66 Nokia Siemens Networks DRAFT Issue
Remote Radio Head FRGH SW Image
FRGH SW Image: FRRH3-SW_00001569.LAR
eNB SW Build
77 Nokia Siemens Networks DRAFT Issue
Setup File Server For SW Download To FRGH
Example shows the file server setup with Filezilla.Create user bbCommander with passwordbb2nodeb$.
Create home directory for user bbCommander.Home directory in this example is C:\home\bbCommander
88 Nokia Siemens Networks DRAFT Issue
Telnet Console To FRGH
Port type must be 2323
99 Nokia Siemens Networks DRAFT Issue
Save The Calibration Files On FRGH
Open a telnet session to FRGH and type following command: flash f CALI caliFile
FTP the calibration file /ram/caliFile from RRH to LMT. Use olli/bolli as FTP user/password.
10
10 Nokia Siemens Networks DRAFT Issue
SW Download To FRGHAny web browser can be used for installation. Set following address and port number in the address line of the web browser: Select TestManager Select SWDL for SW Download Set the data as shown on the slide
Expected outcome.
Set the file name with extension e.g. FRRH3-SW_00001569.LAR
11
11 Nokia Siemens Networks DRAFT Issue
Activate SW Downloaded To FRGH
Tags to be set:OMP1,FDR1,EXT1,BAA1,BAB1,KEN1,MON1,DIR1,CSS1
Set SW image name without extension FRRH3-SW_00001569as activeBuildName and as activeBuildVersion
12
12 Nokia Siemens Networks DRAFT Issue
Activate SW Downloaded To FRGH (cont)
Reboot is required after "FINISHED. SUCCESS: OK"Open telnet session and run the following command:
Mcu -r
New SW is activated on FRGH.
Use following command on telnet to check which SW version is active on FRGH:
swinfo s BUILD
13
13 Nokia Siemens Networks DRAFT Issue
FRGH: R&D Switches Read all non zero parameter values: rad c a
Write R&D SwitchesWrite for example the switch Trap_TestMode (0xC1(hex) == 193(dec) == Trap_TestMethode) to the value 0x1:
rad pw 0xc1 0x1
14
14 Nokia Siemens Networks DRAFT Issue
Set R&D Switch for BTSOM UOM_MTPolling to 0x0
R&D Switch for BTSOMIn case of running BTSOM, set UOM_MTPolling to 0x0 from the telnet with the following command:
rad pw 0x6c 0x0
15
15 Nokia Siemens Networks DRAFT Issue
Retrieve Unit Info From FRGH
TestManager -> UNIT_INFO_STORAGE (Read Operation)
Read the Serial Number from FRGH.
16
16 Nokia Siemens Networks DRAFT Issue
Save Unit Info To FRGH
TestManager -> UNIT_INFO_STORAGE (Write Operation)
Write new Serial Number to FRGH.
17
17 Nokia Siemens Networks DRAFT Issue
FRGH: Useful Commands
Read FRGH SW version, release: swinfo s BUILD
Reset FRGH:Mcu r
TX Statustx stat
RX Statusrx stat
Dapd status:dapd stat
Read Temperature:TX1: thermo read RF1 RX1 & RX5: thermo read RF3
18
18 Nokia Siemens Networks DRAFT Issue
Reconnect FRGH To The FCMD
Power off eNB. Plug out the Ethernet cable on RRH. Plug in a SFP module and connect the fibre optic cable between eNB and FRGH (cable and SFPs on both ends must be of the same type: multi mode or single mode). Power on eNB. Check the status with Pinger
19
19 Nokia Siemens Networks DRAFT Issue
FRGH: Connection Lost
From the load 38, if FRGH does not establish the Obsailink than Ethernet interface on FRGH Service Panel is not provided also. The connection to FRGH is totally lost.
Solution: Plug out the SFP module at FRGH and turn the power off and on.